1. continuous beep will sound if your UPS fails a self test and or the UPS battery is less than fully charged If this occurs let the UPS charge for 12 hours and perform a second self test If the light continues to stay on contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Indicator Lights Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will shine constantly to indicate AC power is VA available at the receptacles It will flash to indicate AC power is not available See System Enable Switch and On Standby Switch descriptions above This multi colored light displays 7 separate UPS battery charge conditions It will turn from red low to yellow medium to green full to show you the level of battery charge If the light is constant your UPS is operating from line power and the battery is charging If the light is flashing your UPS is operating from battery power and the battery is discharging When the light flashes red close any files you are working on and shut down your computer 5 xR S Whenever your UPS is automatically correcting high or low AC line voltage this green light will turn ON and the UPS will gently click The more the UPS has to correct voltage the more the green light will turn ON and the more t
2. support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current qualified service personnel should observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object The UPS batteries are recyclable Refer to local codes for disposal requirements Do not dispose of the batteries in a fire When adding external batteries connect only Tripp Lite battery packs of the correct voltage and type Your UPS s External Battery Connector should match the color of the connector of any battery pack you want to connect Quick Installation Connect the UPS to an electrical outlet and a computer to the UPS e Unplug the computer s power cord from bo
3. the battery charger and intelligent gill microprocessor Always leave it in the ENABLE UP position when your UPS is plugged in Set the switch to DISABLE DOWN only if you store or ship your UPS to reduce battery drain Note the v light will flash until you engage the ON Standby Switch to activate the ON mode power ON at the UPS receptacles ON Standby Switch This momentary switch on the front panel controls power to the UPS receptacles Engage it momentarily and release it to toggle between the ON mode power ON at the UPS receptacles and Standby mode power OFF at the UPS receptacles Mute Test Switch Use this momentary switch on the front panel to do two things Silence the UPS On Battery alarm Engage this switch and release it to silence the UPS On Battery alarm a series of short beeps that sounds intermittantly when the UPS is providing AC power from battery Note when the battery is nearly depleted the Low Battery alarm a continuous beep that cannot be silenced will alert you to immediately shut down connected equipment Test your UPS s battery charge Leave your connected equipment ON With your UPS plugged in and completely turned ON engage this switch hold it there for 5 seconds and release it You will hear a series of short beeps as the UPS momentarily switches to battery to test its charge The Ba light will turn ON and the alarm a long
4. 0V 5 Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB AC TVSS Protection Modes H to N H to G N to G Wire Color Code Chart Wire Color Wire 1 Wire 2 Wire 3 American Black White Green European Brown Blue Green Yellow Wire Reference Wire 1 Wire 2 Wire 3 American Line 1 Neutral Ground European Line 1 Line 2 or Neutral Ground Yellow The policy of Tripp Lite is one of continuous improvement Specifications are subject to change
5. Owner s Manual TRIPP LITE SmartPro INT POWER PROTECTION a 1111 W 35th Street SmartPro XL INT Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com 2200 3000 VA Intelligent Line Interactive UPS Systems 230V ESPANOL p 8 FRANCAIS p 15 DEUTSCH p 22 p 2 Quick Installation p 3 4 Basic Operation p 5 7 Storage amp Service p 7 Specifications p 7 Copyright 2000 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite Safety A N This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems UPS Location Warnings Install your UPS indoors away from excess moisture or heat dust or direct sunlight For best performance keep the indoor temperature between 0 C and 40 C between 32 F and 104 F Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings Connect your UPS to a properly grounded AC power outlet Do not modify the UPS s plug Do not use adapters that eliminate the UPS s connection to ground Do not plug your UPS into itself this will damage the UPS and void your warranty If you are connecting your UPS to a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life
6. Using the grey or tan Tripp Lite cable that came with your UPS connect your primary server s DB9 port to the single DB9 port labeled LAN 4 1 which provides complete intelligent RS 232 communications ott on rt Serial port connections are optional Your UPS will function properly without these connections EERE The LAN 4 1 DB9 port is always enabled and is not controlled by the LAN Interface DIP Switches 2 If you have additional computers a Connect them to the DB9 ports labeled LAN 2 2 which provide basic contact closure shutdown capabilities using the black cables that came with your UPS b Set their corresponding LAN Interface DIP Switches to the ACTIVATE DOWN position See diagram for which switch controls which port Tfyou do not connect a computer to either of 2a Back Panel the LAN 2 2 DB9 ports set their corresponding LAN Interface DIP Switches to the DEACTIVATE UP position Note DIP Switch 3 has no function DIP Switches 2 amp 1 Lan Interface Switches 4 N 4 4 DEACTVATE i d N d N 7 ACTIVATE 2b Back Panel 3 Load software and run the installation program appropriate for your operating system Basic Operation Switches System Enable Switch DIP Switch 4 Z321 This switch is on the back panel in the set of 4 switches next to the UPS s DB9 ports It activates
7. are instructions for details Note constant power is available at the Remote Reboot Outlet and all other outlets unless controlled through Tripp Lite UPS software This port labeled LAN 4 1 on the UPS connects your UPS to a workstation or server Use with Tripp Lite software and cabling to monitor and manage network power and automatically save open files and shut down equipment during a blackout This port uses RS 232 communications to transmit UPS and power conditions Pin 7 Transmit Pin 8 Common Pin 9 Receive Contact Tripp Lite Customer Support for more information and a list of available SNMP network management and connectivity products Contact Closure Ports These ports labeled LAN 2 2 on the UPS are also used to connect your UPS to a workstation or server Use with Tripp Lite software and cabling to automatically save open files and shut down equipment during a blackout This port uses contact closure signals to indicate line fail and low battery status Contact Tripp Lite Customer Support for more information External Battery Connector Use to connect additional Tripp Lite battery packs for additional runtime Refer to the label next to the connector for the appro priate Tripp Lite battery pack to connect Refer to instructions available with the battery pack for complete connection informa tion and safety warnings Storage amp Service Storage Turn your UPS OFF first engage the ON Stand
8. by Switch and release it to place your UPS in the Standby mode then move the System Enable Switch to the DISABLE DOWN position to prevent battery drain then disconnect the UPS power cord from the wall outlet If you plan on storing your UPS for an extended period of time recharge the UPS batteries once every three months Follow steps 1 and 3 in the Quick Installation section and allow the UPS to charge from 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer permanent loss of capacity Service If returning your UPS for service contact your local Tripp Lite dealer or distributor They will refer you to a service center Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the 2 year warranty period enclose a copy of your sales receipt Specifications Smart INT 2200 Smart INT 3000 Output Capacity VA Watts 2200 1700 3000 2400 Battery Runtime Half Load Full Load Minutes 27 11 23 7 Battery Recharge Time 2 4 hrs 2 4 hrs Approvals UL CE UL CE Battery Runtime for this model can be increased with the addition of optional external battery packs Input Voltage 230V Input Frequency 50 60 Hz Auto Selecting On Line Input Voltage Range 166 276 volts Voltage Regulated Output Voltage Range 230V 8 15 On Battery Output Voltage Range 23
9. he UPS will click These are both normal automatic operations of your UPS and no action is required on your part This red light will turn ON if your UPS fails a self test and or the UPS battery is less than fully charged Let the UPS charge for 12 hours and perform a second self test If the light continues to stay on contact Tripp Lite for service This multi colored light displays 4 separate UPS load conditions It will turn from green low to yellow medium to red high as you connect equipment to show you the load level your UPS is supporting When the light is red your UPS is supporting a load above 85 of its capacity If the red light begins flashing then your UPS is severely overloaded Remove overload immediately until light stops flashing Other UPS Features AC Receptacles RS 232 Port The receptacles provide your connected equipment with AC line power during normal operation and battery power during black outs and brownouts They also protect your equipment against damaging surges and line noise You can remotely reboot con nected equipment by turning all of the receptacles OFF and ON at once using Tripp Lite UPS software Select models however feature a unique Remote Reboot Outlet identified on the back panel of your UPS which allows you to use Tripp Lite UPS software to remotely reboot equipment connected to this outlet without interrupting power to equipment connected to the other outlets See softw
10. th your AC outlet and the computer s AC input e Insert the female plug of the computer s cord B into your UPS s AC input Insert the male plug of your computer s cord into your AC outlet e Insert the female plug of the power cord that came with your UPS A into the computer s AC input Insert the UPS cord s male plug into any of your UPS s female output receptacles 2 Plug additional computers and equipment into your UPS Your UPS is designed to support only computer equipment You will overload your UPS if you connect household appliances laser printers or surge suppressors Cords and receptacle adapters are available from Tripp Lite to accommodate most outlet configurations If rewiring is necessary refer to the Wire Color Code Chart in the Specifications section 3 Turn your UPS ON Figure 1 DIP Switch 4 e Set the System Enable Switch DIP System Enable Switch Switch 4 UPS back panel to the Eini ENABLE UP position See Figure 1 This switch activates the battery charger and microprocessor The light will flash until you engage the ON Standby Switch to activate the ON mode e Engage the momentary ON Standby Switch UPS front panel and release it to activate the ON mode and supply power to the UPS receptacles See Figure 2 DB9 Port Connection Optional On Next Page 3 DB9 Port Connection Optional