Home
Tripp Lite SMART2200RM2UN User's Manual
Contents
1. 2 2kVA 1920W capacity e Line interactive UPS with Automatic Voltage Regulation AVR corrects brownouts and overvoltages from 83 to 145V e NEMA 5 20P input plug 4 NEMA 5 15R amp 4 NEMA 5 15 20R output receptacles Two independently switchable output load banks e Maintains uninterrupted operation of connected networking equipment during blackouts surges brownouts and overvoltages e High 96 efficiency rating in line power mode offers reduced power consumption and BTU emisssions e Internal batteries offer 12 minutes at 50 load 960W and 4 5 minutes at 100 load 1920W e Hot swappable user replaceable internal batteries can be replaced with no disruption to connected equipment e Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5 bar battery charge graphic plus 7 selectable screens of detailed UPS and site power information e LCD interface also supports a number of advanced user setup and operating preferences e Ships with 4 post rackmount installation hardware Optional 2POSTRMKITWM enables 2 post rackmount wallmount installation Optional 2 9USTAND enables tower placement e Built in USB RS 232 and Pre installed SNMPWEBCARD accessory monitoring options e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software Built in Emergency Power Off EPO interface with cable Specification
2. enables a variety of UPS setup and configuration options Super fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot 96 line mode efficiency offers reduced heat emissions and operating costs Network management interfaces support communications via USB RS 232 and Pre installed SNMPWEBCARD network interface HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Network communications ports enable detailed monitoring of equipment load levels self test data and utility power conditions Includes PowerAlert monitoring software and complete cabling Switched output load banks enable scheduled and real time remote reboot and load shedding of select outlets Emergency Power Off EPO interface LCD display panel easily rotates for viewing in rackmount or tower configurations Audible alarm with push button momentary alarm cancel and silent mode configuration options Programmable self test Field replaceable hot swappable battery modules Applications Ideal for server networking and telecommunications equipment Package Includes e SMART2200RM2UN UPS system with Pre installed SNMPWEBCARD e PowerAlert Software with USB Serial amp EPO cabling e 4 post rackmount installation kit e Instruction manual Features e Tripp Lite SMART2200RM2UN line interactive 2U rack tower UPS with 2200VA
3. MKITWM Wallmount 2ZPOSTRMKITWM Tower 2 9USTAND Rackmount UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm Installed whole system total rack space height rack spaces Secondary form factor UPS Power Module weight Ibs UPS Power Module weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg UPS housing material Cooling method ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable WatchDog compatibility 3 5 x 17 5 x 19 5 8 9 x 44 4 x 49 4 2U Tower requires 2 9USTAND 57 6 26 1 7 9 x 21 7 x 24 2 20 1 x 55 1 x 61 5 57 6 26 2 Steel Fan 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 306 USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Pre installed SNMPWEBCARD interface Supports detailed monitoring of UPS and site power conditions Included USB DB9 and EPO cabling included Supports Wa
4. Placement of Rackmount UPS Systems 1 2POSTRMKITWM Enables 2 Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems 1 WATCHDOGSW WatchDog Service Monitoring Reboot Software 1 PDU1220 Single Phase Basic PDU 20A 120V 1U Horizontal Rackmount 13 NEMA 5 15 20R 1 outlets NEMA 5 20P input plug PDUV20 Single Phase Basic PDU 20A 120V OU Vertical Rackmount 14 NEMA 5 15 20R outlets 1 NEMA L5 20P input with 5 20P adapter PDUMH20 Single Phase Metered PDU 20A 120V 1U Horizontal Rackmount 12 NEMA 5 15 20R 1 outlets NEMA L5 20P input with 5 20P adapter PDUNV Single Phase Basic PDU 16A 100 240V 1U Rackmount C13 C19 outlets C20 input 1 and C14 L6 20P L5 20P 5 20P and 5 15P adapters PDUMV20 Single Phase Metered PDU 20A 120V OU Vertical Rackmount 28 NEMA 5 15 20R 1 outlets NEMA L5 20P input with 5 20P adapter PDUMNV20 Single Phase Monitored PDU 20A 120V 70 in OU Vertical Rackmount 24 NEMA 1 5 15 20R outlets NEMA L5 20P input with 5 20P adapter PDUMNH20 Single Phase Monitored PDU 20A 120V 1U Horizontal Rackmount 8 NEMA 5 15 20R 1 outlets NEMA L5 20P input with 5 20P adapter PDUMV20NET Single Phase Switched PDU 20A 120V OU Vertical Rackmount 24 NEMA 5 15 20R 1 outlets NEMA L5 20P input with 5 20P adapter PDUMH20AT Single Phase Auto Transfer Switch Metered PDU 20A 120V 1U Horizontal 1 Rackmount 16 5 15 20R outlets 2 L5 20P 5 20P adapters PDUMH20ATNET Single Phase Auto Transfer Switch Switche
5. access door Hot swappable user replaceable batteries Automatic voltage regulation AVR maintains line power operation with an input voltage range of 83 to 145 Input voltages between 127 and 145 are reduced by 12 Input voltages between 108 and 96 are boosted by 12 Input voltages between 83 and 95 are boosted by 24 LEDS ALARMS amp SWITCHES Front panel LCD display Alarms Alarm cancel operation Switches Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data plus configuration of voltage operating mode alarm function and a variety of additional options see manual for detailed LCD configuration and monitoring options Audible alarm indicates UPS startup power failure low battery overload UPS fault and remote shutdown conditions Power fail alarm can be temporarily silenced using alarm cancel switch silent mode alarm configuration option available 3 pushbutton switches control OFF ON power status MODE selection and MUTE ENTER control functions SURGE NOISE SUPPRESSION UPS AC suppression joule rating UPS AC suppression response time EMI RFI AC noise suppression PHYSICAL Installation form factors supported with included accessories Installation form factors supported with optional accessories Primary form factor 570 Instantaneous Yes 4 post 19 inch rackmount mounting rail kit included 2 post rackmount 2POSTR
6. d PDU 20A 120V 1U Horizontal 1 Rackmount 16 5 15 20R outlets 2 L5 20P 5 20P inputs PDUB20 Single Phase Hot Swap PDU 20A 120V 2U Horizontal Rackmount 4 NEMA 5 15R amp 4 1 NEMA 5 15 20R outlets 2 NEMA 5 20P input plugs More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm variables txtModellD 5428 Copyright 2013 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
7. s OUTPUT Output Volt Amp Capacity VA Output kVA capacity kVA Output Watt Capacity watts Output kW capacity Output power factor Nominal Output Voltage s Supported Frequency compatibility Output voltage regulation line mode Output voltage regulation Battery mode Built in UPS output receptacles Built in controllable switched load banks Output AC waveform AC mode Output AC waveform battery mode INPUT Rated input current at maximum load Nominal Input Voltage s Supported UPS input connection type Input circuit breaker UPS Input cord length ft UPS Input cord length m Recommended Electrical Service BATTERY 2200 2 2 1920 1 92 0 87 120V 60 Hz 14 6 5 4 5 15R outlet s 4 5 15 20R outlet s Two switchable single outlet load banks Pure Sine wave Pure Sine wave 16A 120V 120V AC 5 20P 20A 10 20A 120V Full load runtime minutes Half load runtime minutes DC system voltage VDC Battery recharge rate included batteries Replacement battery cartridge internal UPS battery replacement Battery Access Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction Severe undervoltage correction 4 5 min 1920w 12 min 960w 48 Less than 4 5 hours from 10 to 90 RBC94 2U Front panel battery
8. ss Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 lt E mail saleshelp tripplite com Model SMART2200RM2UN SmartPro 2 2kVA 1 92kW Line Interactive Sine Wave UPS Pre installed SNMPWEBCARD 2U LCD USB Serial EPO 120V Highlights e 2 2kVA 2200VA 1920W line interactive 2U rack tower UPS 0 87 power factor e 120V nominal output during brownouts to 83V and overvoltages to 145V e Interactive LCD provides UPS status information and advanced configuration options e Hot swap batteries 96 efficiency Sine wave output e USB RS232 amp EPO ports Pre installed SNMPWEBCARD interface e 2 independently switchable output load banks e NEMA 5 20P input 4 NEMA 5 15R amp 4 5 15 20R outlets Description Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network grade power protection for critical server network and telecommunications equipment Line Interactive Uninterruptible Power Supply UPS with built in Auto Voltage Regulation AVR actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure Tripp Lite s unique configuration excels in exceptionally poor power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions Interactive LCD interface reports UPS operating mode detailed UPS and site power data plus
9. tchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time 5 milliseconds AC to battery mode 1 millisecond Battery to AC mode Low voltage transfer 83 to battery power setpoint High voltage transfer 145 to battery power setpoint SPECIAL FEATURES Grounding lug Back panel grounding lug Cold Start startup in Cold start operation supported battery mode during a power failure High availability UPS Hot swappable batteries features Green amp high Greater than 95 efficiency GREEN UPS Individually controllable load banks efficiency features CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category A EMI WARRANTY Product Warranty 2 year warranty 3 year with registration Note registration is required for 3 year warranty Period Worldwide Connected 250 000 Ultimate Lifetime Insurance Equipment Insurance U S Canada amp Puerto Rico Related Items Optional Products Related Model Description Qty WEXT5 2200 3000 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack 1 models 2200 3000VA or less ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires UPS with 1 SNMPWEBCARD monitored PDU or switched PDU SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 2 9USTAND Enables Tower