Home

Tripp Lite ENVIROSENSE User's Manual

image

Contents

1. This model includes an additional 5 15P plug which can be installed in place of the existing plug Installing the additional plug will change the output capacity 4 Converts to ten 5 15 20R two L6 20R and one L6 30R outlets via optional SUPDM12 or SUPDM13 Converts to L6 30P plug via optional SUPDM12 or SUPDM13 Converts to two L6 30R outlets via optional SUPDM11 Converts to L6 30P plug via optional SUPDM11 D Certifications vary by model The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice Actual product may differ slightly from photos Complete up to date specifications including product weight and dimensions available at www tripplite com Also available interactive UPS System selector guide extended warranties owner s manuals and more 11
2. System Rear Panel with Isolation Transformer Module and External Battery Pack GUTT 1 BREAKER 20A 54 yg F tj Caa a i Tita a Reza DRY CONTACT Emergency Power Off Phone DSL Ethernet Surge Protection Select Models A modular jack included with select models allows remote emergency Protect Internet connected or networked computers from damage on shutdown All other models can perform emergency shutdown by a single phone DSL Ethernet line with surge protected jacks featured attaching an optional cable model 73 0909 sold separately to the on select models communication port The optional cable includes a DB9 connector to Variety of Output Options allow server support and a modular jack to allow emergency shutdown 15 20 and 30 amp receptacles on select models ensure maximum T Hardwire Single Phase Input connection flexibility To convert select models to hardwire input and output select optional Front Panel Battery Replacement not shown hardwire input output PDUs To add an input plug and receptacles to 1 000 to 3 000 VA models feature a convenient front access door SU6000RT3U and SU6000RT3UHV select SUPDM alternate back panel to replace internal batteries All models allow hot swap accessories battery replacement Tripp Lite offers a complete line of replacement battery cartridges R B C visit www tripplite com Hot Swappable Modular Models 100 Availability Features Internal Bypass e External Bypa
3. 120 18 4 hardwire 8000 module 3U battery 50 60 2 L6 30R module amp 4U 12 5 15 20R 2 transformer E SU10KRT3UHV 10000 10 4 3U power 156 276 208 240 aa hardwire 8000 module amp 3U 50 60 batter ante E SU10KRT3U 10000 10 4 3U power module 156 276 pane ull hardwire O 8000 3U battery module 50 60 amp 3U transformer E SU16000RT4U 16000 12 5 AU power 100 140 60 208 240 5 5 15 20R 1 hardwire 11200 module amp 4U L N amp 120 A L6 30R 4 wire battery module 6 C19 E SUT6000RT4UHW 16000 12 5 AU power 100 140 60 208 240 hardwire 1 1 hardwire 11200 module amp 4U L N amp 120 4 wire battery module Complete up to date specifications including product weight and dimensions available at www tripplite com Also available interactive UPS System selector guide extended warranties owner s manuals and more COMPLIANT Extend Runtime Runtime minutes with additional external battery packs Load Runtime minutes with Non Expandable Expandable Battery Pack s All models accept external c Watts included batteries Battery Pack 1 2 3 4 l SU750RTXL2U BP24V28 2U BP24V70 3U battery packs to provide BE 300 11 0 88 0 224 4 933 8 extended runtime Without 600 523 3 Wi SU1000RTKL2Ua BP24V28 2U BP24V70 3U enough runtime businesses 400 17 4 77 6 199 6 413 3 628 1 841 1 stand to lose up to 50 000 800 i REZ Pe EC Eee ean PANE TPA l a SUT500RTKL2Ua BP48V
4. 24 2U BP48V60RT3U per hour according to a recent 600 170 80 3 164 6 334 2 506 1 677 5 survey on the cost of lost 1200 320 2 odet an ra SU2200RTXL2Ua BP48V24 2U BP48V60RT3U p y E 800 14 0 56 2 117 0 241 9 370 3 499 3 network downtime Locate 1600 4 5 23 1 49 7 232 f SU3000RTXL3U amp SU3000RTXL3UHV BP72V15 2U BP72V28RT 3U your planned eae ane ana ml 1200 77 6 1578 2419 3073 runtime on the chart to me 2400 6 0 16 8 32 8 149 5 TEN SU3000RTXR3U BP72V15 2U BP72V28RT 3U 1200 33 0 58 8 97 1 178 6 263 1 348 8 Waa A me 2400 159 9 SU5000RT3U amp SU5000RT3UHV BP240V10RT3U 1740 291 0 3500 30 6 70 2 100 0 130 9 SU5000RT4U BP192V12 3U 1740 313 8 Wi 3750 131 7 SU6000RT3U amp SU6G000RT3UHV BP240V10RT3U 2100 237 9 4200 15 0 N A 33 4 55 9 80 0 105 1 Wi SUGO00RT4U BP192V12 3U bia Naka sarap Gad 2100 24 0 256 0 Wa 4200 90 Ho P paa mi SUS000RT4U BP192V12 3U 2800 183 8 mi 5600 81 1 SU8000RT3U SU8000RT3U1TF amp SU8000RT3UHW BP240V10RT3U For additional extended runtime a 30 H E an an ik gt solutions to fit your specific load SU10KRT3U SU10KRT3UHV SU10000RT3U amp SU10000RT3U2TF BP240V10RT3U requirements use Tripp Lite s 4000 110 0 interactive UPS Selector Guide at 13 7 prie 7 34 1 45 3 ee U16000RT4U amp SU16000RT4UHW BP192V18 4 Oe Doge gee 5600 130 9 ot cal UDR Lite SBE caLOn 11200 C w 55 9 Specialists at 77 3 869 1236 Included batteries are contained either internally within the UPS system or are offered as an external mod
5. T4U 5000 17 8 65 140 6 208 240 amp 5 15 20R 1 1 L14 30P 10 3800 L 120 2 L6 20R split phase 2 Ti SOR 4 wire E SU5000RT3U 5000 20 8 3U power 156 276 208 amp 120 2 L6 20R L6 30P 10 3500 module 50 60 2 L6 30R 2U battery 12 5 15 20R module amp 2U transformer E SU5000RT3UHV aaa 20 8 3U power 156 276 208 240 L6 30P 10 3500 module amp 50 60 2U battery modue E SU6000RT4U 6000 24 9 65 rit 208 240 a 15 20R 1 L14 30P 10 4200 amp 120 2 L6 20R split phase 2 iL 30h 4 wire E SU6000RT3U 6000 37 15 3U power 156 276 208 240 hardwire hardwire 4200 module 3U 50 60 amp 120 battery module amp 3U transformer E SU6000RT3UHV 6000 37 15 3U power 156 276 208 240 hardwire hardwire 4200 module amp 50 60 3U battery E SU8000RT4U 8000 12 5 AU 65 140 60 208 240 4 5 15 20R 1 hardwire 5600 L N amp 120 2 L6 20R split phase 2 L6 30R 4 wire ir hardwire E SU8000RT3U 8000 15 6 3U ee 156 276 208 240 4 L6 20R hardwire 6400 module amp 50 60 Oe 30F 3U battery ene E3 SU8000RT3U1TF 8000 15 6 3U power 156 276 208 amp 120 18 4 hardwire 6400 module 3U 50 60 2 battery module 12 5 15 20R amp 2U transformer E SU8000RT3UHW 8000 15 6 156 276 208 240 hardwire hardwire 6400 50 60 0 E SU10000RT3U 10000 10 4 3U power 156 276 208 240 hardwire 8000 module amp 50 60 E SU10000RT3U2TF 10000 10 4 3U power 156 276 208 amp
6. TRIPP LITE RACKMOUNT TOWER UPS SmartOnline Single Phase Intelligent True On Line UPS Systems nn We ya mg SU3000RTXL3UHV amp SU3000RTXR SU3000RTXL a oe SU5000RT3U SU5000RT3UHV SU6000RT3U SUGO00RT3UHV SU8000RT3U SU8000RT3U1TF SU8000RT3UHW SU1T0000RT3U SUTO000RT3U2ZTF SUTOKRT3UHV SU10KRT Power module shown Deliver True On Line Pure Sine Wave Zero Transfer Time Operation SmartOnline Rackmount Tower UPS Systems provide mission critical equipment with the highest level of power protection Double conversion technology continually converts incoming AC power into filtered DC power and then resynthesizes it back into AC power with a pure sine wave Constant on line operation completely isolates sensitive equipment from every power problem on the AC line SmartOnline models accept the widest range of incoming voltage and frequency variations delivering the most consistently pure highly regulated AC power 3 V or 2 V and 0 05 Hz SmartOnline Rackmount Tower UPS Systems provide reliable battery power with zero transfer time to keep networks up and running through short blackouts and allow enough time to safely shut down during longer ones In addition they stop damaging surges and filter disruptive line noise Tripp Lite UPS Comparison Index SmartOnline TRUE ON LINE gt 750 16 000 VA gt Zero Transfer Time Double Conversion gt Wide Input Voltage Range with Precision Regu
7. ackmount Tower UPS Systems include an automatic internal bypass that ensures 100 availability of connected equipment by passing through utility power in the event of an internal fault or overload Hot Swappable Modular models include two additional features that ensure continuous availability an external maintenance bypass switch and a modular design When the external switch is set to bypass the UPS module can be removed for maintenance while the detachable PDU module remains installed continuing to power connected equipment as long as utility power is present Adapt to Rack Tower Stack Applications Adapt all models from rackmount to tower or stacking applications e Removable rack hardware e Optional base stands SU3000RTXL3U tower mount with optional base stands SU6000RT3U or SUIOKRT3U tower mount with optional base stands Optional base stands model 2 9USTAND are available to adapt any combination of models from 2U to 9U wide to tower mounting Display Critical Operational Conditions SmartOnline Rackmount Tower UPS Systems feature a front panel LED display or combination LCD LED display which shows a variety of UPS operational modes and conditions This interface provides more information than comparable models allowing you to react more rapidly to an alert before your systems are put at risk LED Display 1 Battery amp Load Conditions The Load and SEAT cee E Battery Active Meters allo
8. lated Output gt Internal or External Batteries amp Extended Runtime Options gt Automatic Internal Bypass gt Maintenance Bypass amp Detachable PDU Options gt Rack Tower Stack Adaptable Manage Multiple Servers Multiple built in communication ports provide the ability to simultaneously manage multiple servers without the need for accessories Using PowerAlert Software select models with multiple communication ports will simultaneously provide intelligent communications shutdown commands and reporting on multiple servers even if they are running different operating systems Intelligent communications allow you to check UPS status including battery charge level and AC power status as well as reboot Customized Load Management Banks Additional PowerAlert features pages 24 and 25 Control Individual Outlets Prioritize the uptime of mission critical loads during a power failure with Customized Load Management Banks featured on select models Customized Load Management Banks can be controlled independently through PowerAlert Use PowerAlert to reboot a locked up computer by cycling the power on and off to select receptacles on the UPS system You can also program PowerAlert to shut down less important systems during an extended blackout preserving battery runtime for more critical equipment Hot Swap the UPS Module ETAT 0 W ESB U P PDU Module Continues Powering Equipment All SmartOnline R
9. ss Switch e Modular Design Detachable UPS Module PDU Module amp Battery Module e Hot Swappable Batteries Select models feature internal batteries SU6000RT4U UPS System Rear Panel with Internal Batteries AG PUT w ers SC A i SU10000RT3U eee ee i UPS System Rear acesior ak A sa tp NORMAL Panel with External AN Battery Pack BATTE iY INPUT TANAH a E CAUTION GD NOT DISCONNECT UNDER LOAD agan aT k ji Pi Ji oO Tap REJA DRY CONTACT SU5000XFMRT2U Isolation Transformer Module Rear Panel 10 Specifications Communication Ports Smart Contact a Closure Backup Time Capacity Typical Minutes Battery Half Full Load Packs AC Receptacles Quanti NEMA Typ UPS Systems E SU750RTXL2U 750 11 44 aa 65 138 120 100 EJ 5 15ROE TE 5 15P 10 600 50 60 110 120 E su1000RTXL2Ua 1000 14 4 5 ABE w 65 138 120 100 KH 5 15ROe er 5 15P 10 50 60 0 ae 20 E SU1500RTXL2Ua sw 17 5 a A 65 138 120 100 KENI 5 15ROe Mae sea 5 15P 10 1 no 20 a 0 no 1 L5 20R 0 E SU3000RTXL3U mw 14 5 E F 65 138 120 4 5 15R 1 1 L5 30P 10 50 60 110 120 4 5 15 20R 1 L5 30R E SU3000RTXR3U 3000 33 14 E F 65 138 120 i 5 15R 1 L5 30P 10 2400 50 60 110 120 NA 1 50 1 ia 30R me I SU3000RTXL3UHV ad 17 6 E F 160 275 208 240 6 6 15 20R 166 L6 20P 10 50 60 0 2 L6 20R E SU5000R
10. stem s detachable PDU for SU16000KRT4U model only SUPDM11 Converts hardwired to L6 30P plug cord amp two L6 30R outlets 200 208 240V for SUBDDODRT3UHV model only SUPDM12 Converts hardwired to L6 30P plug cord amp 13 outlets ten 120V 5 15 20R two 208V L6 20R one 208V L6 30R for SU6000RT3U model only SUPDM13 Converts hardwired to L6 30P plug cord amp 13 outlets ten 120V 5 15 20R two 240V L6 20R one 240V L6 30R for SU6000RT3U model only SNMPWEBCARD Internal SNMP Web management accessory card connects compatible UPS systems to Ethernet ENVIROSENSE Allows UPS to monitor external temperature humidity amp contact closure inputs requires SNMPWEBCARD 2 9USTAND Tower kit with 2 adjustable base stands 2U to 9U 2POSTRMKITWM Horizontal mounting rails for 2 post rackmount installation For all UPS and battery pack models Common specifications for all UPS systems SNMP Web accessory slot for use with optional SNMPWEBCARD sold separately All models are designed with mounting hardware to fit standard 19 in racks Backup times are expandable using external battery packs A Optional SUS000XFMRT2U isolation transformer is available to provide 100 120V output Backup times will vary depending on battery condition and load Auto selecting frequency D Includes customized load management receptacles Includes phone DSL Ethernet surge protection P Includes a single combination RS 232 and contact closure port
11. ule depending on model Battery packs which are expandable can be connected together for increased runtime Model Description External Battery Packs and Accessories A BP24V28 2U 24V external battery pack and cable 2U Not expandable RED BLACK 2 point connector B BP24V70 3U 24V external battery pack and cable 3U Expandable RED BLACK 2 point connector C BP48V24 2U A8V external battery pack and cable 2U Not expandable BLUE 2 point connector D BP48V60RT3U A8V external battery pack and cable 3U Expandable BLUE 2 point connector E BP72V15 2U 72V external battery pack and cable 2U Not expandable BLACK 3 point connector F BP72V28RT 3U 72V external battery pack and cable 3U Expandable BLACK 3 point connector G BP192V12 3U 192V external battery pack and cable 3U Expandable BLACK 3 point connector H BP192V18 4U 192V external battery pack and cable 4U Expandable YELLOW INSULATED 2 point connector 1 BP240V10RT3U 240V external battery pack and cable 3U Expandable BLACK 3 point connector SU5000XFMRT2U 2U rack tower mount isolation transformer 208V input L6 30P plug 100 120V output Outlets 12 5 15 20R and 1 L6 30R SUPDM56HW Hardwire PDU Replaces UPS system s detachable PDU for SU5000RT4U SUGO000RT4U models only SUPDMB710HW Hardwire PDU Replaces UPS system s detachable PDU for SU8000RT3U SU10000RT3U models only SUPDMB16KHW Hardwire PDU Replaces UPS sy
12. w you to monitor the percentage levels NA 25 100 of two conditions 1 battery charge as equipment is supported by the UPS system during a blackout and 2 the total amount of the UPS system s capacity that the equipment load is utilizing under normal operating conditions 2 Fault Warning amp UPS System Operational Conditions LED set alerts you to several fault conditions including wiring faults in the wall outlet and warning conditions including the need to recharge or replace the UPS system s internal battery It also indicates UPS system operational status including normal on line operation bypass operation due to fault or overload or on battery operation due to a blackout or severe brownout Combination LCD LED Display 3 LCD Display LCD Display lets you access more precise information than provided by LEDs alone View over 45 separate fault warning and UPS system operational SmMarRTOnNnune UPS conditions including operational mode alarm shutdown conditions input output voltage frequency battery voltage load percentage and more 4 LED Display LED set is organized into a flow chart that indicates UPS system operational status including normal on line operation bypass operation due to fault or overload or on battery operation due to a blackout or severe brownout Feature Focus 0 Extended Runtime Capability E Bypass Operation All models feature connectors that accept optional e
13. xternal An external maintenance bypass switch allows the UPS module 6 battery packs for additional runtime External batteries can be to be removed for maintenance while continuously passing hot swapped See Extended Runtime Chart on page 11 to locate the through utility power to connected equipment perfect SmartOnline Rackmount Tower model that fits your runtime needs NMS Integration Detachable PDU Accessory slot accepts an optional internal Passes through power to connected equipment if UPS module is SNMP Web card for remote shutdowns reboots removed for maintenance and more Use card with optional environmental Customized Load Management sensor to remotely monitor environmental Select models feature special load banks that you control conditions or to control alarm security systems Model SNMPWEBCARD Model ENVIROSENSE Short Circuit Protection Circuit breakers help guard against input output short circuits and system overloads independently through PowerAlert Software Server Support Up to two built in communication ports on select models simultaneously provide shutdown commands and reporting on multiple servers without the need for accessories Standard Models 100 Availability Features Internal Bypass e Hot Swappable Batteries SU2200RIXL2Ua UPS System Rear Panel with Internal Batteries SU3000RTXL3U SU3S000RTXR3U UPS System Rear Panel with Internal Batteries SU5000RT3U UPS

Download Pdf Manuals

image

Related Search

Related Contents

杉並区保守点検業務委託標準仕様書  99-10251-IT-2015-01 Libretto Istruzioni.cdr  User`s Manual(S)  Emerson 200kW User's Manual  gebrauchsanweisung brugsanvisning instrucciones de uso  ATMOS® Record 55 - This is the ATMOS Content Delivery Network  télécharger ici  

Copyright © All rights reserved.
Failed to retrieve file