Home

Tripp Lite B022-U08-IP User's Manual

image

Contents

1. 8 _ a METE Gr ee IP KVM N LINE SELECTED ONLINE SELECTED 8 PORT Model B022 U08 IP El Port Selection Pushbuttons These buttons toggle between the computers attached to the corresponding KVM ports e Simultaneously pressing and holding buttons and 2 for three seconds will perform a keyboard mouse reset e Simultaneously pressing and holding buttons 7 and 8 for three seconds will initiate an Auto Scan A Port LEDs The Port LEDs are built into the Port Selection Pushbuttons e An Online LED on the left side of the pushbutton will illuminate Orange to indicate that a powered on computer is connected to the corresponding port e A Selected LED on the right side of the pushbutton will illuminate Green to indicate that the corresponding port has the focus of the KVM El Reset Button Press this recessed button with a thin object to perform a system reset 4 3 2 Rear View ANE TRIPP LITE 8 PORT Model BO22 U08 IP oI El Daisychain Out Port A P772 Series Daisychain Cable sold separately connects between this port and the Daisychain In Port on a B022 U16 or B022 016 KVM switch to expand the number of connected computers KVM Ports The custom wired KVM cable kits that connect to the computers plug in here Grounding Terminal The wire user provided used to ground the B022 U08 IP connects to the KVM here Cable Tie Slot A cable tie can be routed through this slot in order to tie the connected cabl
2. Note 1 The screenshot depicts the Administrator s Main Screen The User Main Screen does not have the F4 and F6 functions since they can t be accessed by ordinary Users and are reserved for the Administrator 2 OSD always starts in List view with the highlight bar at the same position it was when the OSD was last closed 3 Only the ports that have been set accessible by the Administrator for the currently logged in User are visible 4 If the port list is collapsed into stations simply click on the plus sign next to the desired station number or highlight the desired station number and hit the Enter key 6 2 Local Console Port Access Once logged into the KVM you can access connected computers via the local console using the Local Console OSD Local Console Pushbuttons or Hotkey Commands 6 2 1 Local Console OSD Invocation Sequence Once logged into the KVM switch and accessing a connected computer you will need to use one of two sequences to re open the OSD Main Menu Scroll Lock Scroll Lock or Ctrl Ctrl The default OSD invocation sequence is Scroll Lock Scroll Lock 10 6 KVM Operation continued 6 2 2 Local Console OSD Navigation When in the Local Console OSD you can use your keyboard and mouse to access its features e To close out of the Local Console OSD click the X at the upper right corner of the OSD or press the Esc key e To logout press the F8 key click the F8 at the top of the OSD or
3. Read all of these instructions Save them for future reference Follow all warnings and instructions marked on the device Do not place the device on any unstable surface cart stand table etc If the device falls serious damage will result Do not use the device near water Do not place the device near or over radiators or heat registers The device cabinet is provided with slots and openings to allow for adequate ventilation To ensure reliable operation and to protect against overheating these openings must never be blocked or covered The device should never be placed on a soft surface bed sofa rug etc as this will block its ventilation openings Likewise the device should not be placed in a built in enclosure unless adequate ventilation has been provided Never spill liquid of any kind on the device Unplug the device from the wall outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning The device should be operated from the type of power source indicated on the marking label If you are not sure of the type of power available consult your dealer or local power company This device is designed for IT power distribution systems with up to 230V phase to phase voltage The device is equipped with a 3 wire grounding type plug This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not
4. Protocol IPv4 v Network adapter MAC 00 25 64 bd 9b 0d IP 172 18 12 96 IPv4 settings 5 6 3 Browser By default the BO22 U08 IP is set to have an IP address assigned automatically via DHCP server If this is the case you will need to obtain the IP address from your network administrator If connected to a network without a DHCP server it boots with a default IP address The default IPv4 and IPv6 addresses can be found on the sticker on the bottom of the unit l 2 Enter the unit s IP address into your web browser You may be prompted by a screen stating that there is a problem with this website s security certificate Click on the option to continue to the website anyway See Web Browser Login section for details on installing the security certificate You will be brought to a login page Enter the default User Name administrator and the default Password password The Web Management Interface will open upon entering the User Name and Password 5 Installation continued 5 6 3 Browser continued 4 Click on the Network icon at the top of the page to bring up the Network settings page Program 9000 HTTP 80 HTTPS 443 IPv4 Configuration IPv6 Configuration J Obtain an IP address automatically DHCP Set IP address manually Fixed IP IP Address Obtain an IP address automatically DHCP _ Set IP address manually Fixed IP 192 168 1 180 IP Address Subnet Mask 255 255 2
5. Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details FCC Notice Class A This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user must use shielded cables and connectors with this equipment Any changes or modifications to this equipment not expressly approved by Tripp Lite could void the user s authority to operate this equipment WEEE Compliance Information for Tripp Lite Customers and Recyclers European Union Unde
6. attempt to defeat the purpose of the grounding type plug Always follow your local national wiring codes Do not allow anything to rest on the power cord or cables Route the power cord and cables so that they cannot be stepped on or tripped over If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes Consideration should be given to the connection of equipment to the supply circuit and what effect overloading the supply circuit might have on overcurrent protection and supply wiring To help protect your system from sudden transient increases and decreases in electrical power use a Tripp Lite Surge Suppressor Line Conditioner or Uninterruptible Power Supply UPS Position system cables and power cables carefully be sure that nothing rests on any cables When connecting or disconnecting power to hot pluggable power supplies observe the following guidelines e Install the power supply before connecting the power cable to the power supply e Unplug the power cable before removing the power supply e Ifthe system has multiple sources of power disconnect power from the system by unplugging all power cables from the power supplies Never push objects of any kind into or through cabinet slots They may touch dan
7. sure that the stabilizers are secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack e Always load the rack from the bottom up and load the heaviest item in the rack first e Always load the rack so that a hazardous condition is not created due to uneven loading e Make sure that the rack is level and stable before extending a device from the rack e Use caution when pressing the device rail release latches and sliding a device into or out of a rack the slide rails can pinch your fingers e After a device is inserted into the rack carefully extend the rail into a locking position and then slide the device into the rack e Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 of the branch circuit rating e Ensure that proper airflow is provided to devices in the rack e Do not step on or stand on any device when servicing other devices in a rack e Do not connect the RJ11 connector marked Upgrade to a public telecommunication network e Caution Slide Rail LCD KVM mounted equipment is not to be used as a shelf or a work space CAUTION Slide rail mounted equipment is not to be used as a shelf or a workspace 5 Installation continued 5 2 Rack Mounting Instructions Stan
8. 0284 B020 m e020 7 B020 m eoz Baso 68 20 29 JE 3 31 Pm 6 KVM Operation continued 6 4 1 Port Access via Remote OSD The remote OSD displays the ports and KVM stations in the installation in a tree format KVM stations are displayed with a sign next to them which when clicked will display or hide the ports on that KVM To access a port in the installation you can double click on the desired port or use the A and keys to highlight it and hit the Enter key 6 4 2 Port Access via Remote OSD Toolbar In addition to the remote OSD a remote OSD toolbar is provided for greater control of the connected ports The remote OSD toolbar contains icons that when clicked allow you to quickly switch between ports start an auto scan or invoke panel array mode 7 lid doh wT De 101 04 e To open the remote OSD toolbar hit the Scroll Lock key twice The OSD hotkey can be changed from Scroll Lock to Ctrl in the Configuration page of the remote OSD see the Remote OSD Configuration Tab section in the Owner s Manual for details e When the remote OSD toolbar is opened ordinary keyboard and mouse functionality is suspended The mouse functionality will be limited to the remote OSD toolbar only The keyboard functionality will be limited to the hotkey commands mentioned below and the Ctrl Alt Delete command for the local computer Pressing the Esc key will close the remote OSD to
9. 55 0 Prefix Length Default Gateway 192 168 1 1 Default Gateway Obtain DNS server address automatically Obtain DNS server address automatically Set DNS server address manually Set DNS server address manually Preferred DNS server 192 168 1 2 Preferred DNS server Alternate DNS server 192 168 1 3 Alternate DNS server Enabled View Only J Disabled 5 6 4 Non Browser Clients The CD that comes with the product includes Windows and Java Client applications that allow you to remotely access the KVM without using a web browser The applications function the same but the Windows Client is designed for Windows computers whereas the Java client is designed for either Windows or non Windows computers When accessed from a computer that is on the same network as the KVM the client will search the network for the device and display it in a device list for you to access If accessed from a computer that is not on the same network as the KVM you must obtain the IP address from your network administrator and manually enter it into the client See the Browser section above for information on obtaining the IP address To use the Windows or Java client to assign a fixed IP address follow the steps below 1 Save the Windows or Java client from the CD to a desired location on your computer Double click the file to open it 2 When accessing the Windows Client for the first time it will need to be installed on you
10. B022 U16 Tear a ere TO NEXT STATION 5 6 Network Setup IP Address Configuration El Power OFF all computers that are being connected to the KVM switch B Using a P772 Series Daisy Chain Cable sold separately connect the Chain Out port on the back of the first stage KVM to the Chain In port on the back of the next stage KVM The distance between any two KVM switches in a daisy chain must not exceed 49 ft 15 m The distance between the first KVM switch and the last KVM switch in a daisy chain must not exceed 328 ft 100 m regardless of the number of KVM switches in the entire chain E Repeat step 2 for each additional KVM switch you wish to add to the installation with a maximum of 16 levels El Connect a P778 Series USB PS2 Combo KVM Cable Kit between an available KVM port and a computer server P778 Series Cable Kits allow you to connect to a computer with either USB or PS 2 keyboard mouse ports without the need for separate cables Note The distance between the KVM and the connected computer must not exceed 33 ft 10 m El Repeat step 4 for each additional computer server you wish to add to the installation 9 Connect the included external power supply to the BO22 U08 IP and then plug it into a Tripp Lite Surge Suppressor PDU or Uninterruptible Power Supply UPS Turn on the first stage KVM switch The Station ID on the KVM s keyboard panel will display Ol Connect the external power supply inclu
11. OSD will appear with the following page displayed F1 GOTO F3 SET F5 SKP F7 SCAN a F4 ADM F6 BRC F8 LOUT ADMINISTRATOR LIST ALL SN PN QV X AAU S ABC COMP1 ABC COMP2 ABC COMP3 WEB SERVER 1 WEB SERVER 2 FAX SERVER 1 FAX SERVER 2 MAIL SERVER 1 5 Installation continued 5 6 1 Local Console continued 2 3 4 Press the F4 key to bring up the OSD Admin page In the OSD Admin page highlight SET IP ADDRESS and press the Enter key DHCP The first field allows you to enable or disable DHCP When enabled the KVM is assigned an IP address by the DHCP server This setting is enabled by default To disable the DHCP setting and set up a fixed IP address press the Spacebar key Once the DHCP is disabled you will be allowed to edit the remaining fields in the SET IP ADDRESS screen In the remaining fields enter in the IP address subnet mask and default gateway you want to assign to the KVM switch Press the Esc key to exit the SET IP ADDRESS screen and to pull up a prompt asking if you wish to save the settings you just entered If you do not wish to save the settings press the N key If you do wish to save the settings press the Y key Upon pressing the Y key the settings will be saved and the KVM will be reset 5 6 2 IP Installer The CD that comes with the product includes a Windows based ZP 3 Select your KVM from the Device List Note If the list is empty or Installer utility that can be used t
12. Quick Start Guide NetDirector 1U Rackmount KVM Switch with IP Access Model BO22 U08 IP OVER YEARS Manufacturing Excellence TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2013 Tripp Lite All rights reserved All trademarks are the property of their respective owners The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice 1 FCC Information This is an FCC Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 2 User Notice All information documentation and specifications contained in this manual are subject to change without prior notification by the ma
13. able Kits 4 2 3 Remote Console For best results computers that remotely access the KVM switch should have at least a Pentium III 1 GHz processor Users who want to access the KVM switch with the Windows Client must have DirectX 8 0 or higher installed DirectX is available for free download from Microsoft s Website http www microsoft com downloads Users who want to access the KVM switch with the Java Client must have Sun s Java 6 update 3 or higher runtime environment installed Java is available for free download from the Sun Java Website http java com For best results a network transfer speed of at least 128 Kbps is recommended Browsers must support 128 bit data encryption To run the Log Server you must have the Microsoft Jet OLED8 4 0 or higher driver installed Versions Supported The B0O22 U08 IP uses custom P778 Series USB PS2 Combo KVM Cable Kits which can be used to connect to a computer with either USB or PS 2 connectors One cable kit is required for each connected computer 4 2 6 Operating Systems Supported operating systems are shown in the table below Operating System Versions Supported 2000 and higher Linux RedHat 7 1 and higher Core 5 and higher Linux SUSE 9 0 and higher Linux Mandriva Mandrake 9 0 and higher Operating System Versions Supported UNIX AIX 3 51 and higher 4 Introduction continued 4 3 Components 4 3 1 Front View rk RESET 1 pAuTo SCAN
14. and access the connected computers The same as with the AP clients once the Windows Client and Java Applet are opened the screen of the first connected computer on the installation that you have access to 1s displayed as well as the Remote OSD Note The Java applet requires that the Java Runtime Environment JRE be installed on your computer The JRE is available for free download from the Java web site http java com 13 4 A prompt appears asking you to enter your username and password If accessing the KVM for the first time enter in the username administrator and the password password For security purposes it is strongly recommended that you change the username and password on this account to something unique x Username Remember password n Password 5 When you have entered your username and password the screen of the first connected computer on the installation that you have access to is displayed as well as the Remote OSD eF7 O82 Ha cau 10 3 75 1 2 start x 2 david B020 B020 B020 B020 93290 93284 W B020 B020 FA Bo2o 1 B020 C cs70 68 20 29 J 3 31PM 08 19 IP JavaClient Version 1 0 093 lain Configuration Administration isla Coe mrpr 3 iC 75 1 start Eue vavid Bozo m eo20 m eo20 W B020 93290 9
15. appears requesting you to input your serial number The serial number can be found on the CD that comes with the KVM Key in the serial number 5 characters per box then click OK ceca til Number Serial Number I i l f f E 6 KVM Operation continued 6 3 2 Logging In via the AP Windows Client continued 5 Upon entering the serial number the AP Windows Client main screen appears sel xi Server List IP Address 197 165 0 60 Remate view 9000 Ghange Password Login Logout 6 The AP Windows Client will search the network for any KVM switches and display their Model Name and IP Address in the main screen s Server List If the KVM you wish to connect to 1s displayed in the list highlight it and click the Login button If not type in the IP address and port number assigned to the desired KVM switch and click the Login button Note The default port number assigned to the KVM is 9000 7 A prompt appears asking you to enter your username and password If accessing the KVM for the first time enter in the username administrator and the password password For security purposes it is strongly recommended that you change the username and password on this account to something unique x Username Password a n Remember password SUPP cancel 12 8 When you have entered your username and password the Remote View and Change Password buttons on
16. click the zZz symbol in the upper right hand corner of the OSD To move through the OSD list one line at a time click the up and down triangle symbols a W or use the and Ww keyboard keys If there are more entries than appear on the screen the screen will scroll To move up or down one screen at a time click the Up and Down Arrow symbols or use the Pg Up and Pg Dn keyboard keys If there are more entries than appear on the screen the screen will scroll e To activate a port double click it or highlight it and press the Enter key Once a port is accessed the OSD will close and the screen of the computer connected to the port will be displayed 6 3 Logging Into the KVM over IP There are three methods that can be used to connect to the KVM switch over IP Web Browser AP Windows Client and AP Java Client 6 3 1 Logging In via Web Browser 1 Open your web browser and type in the IP address of the KVM See Network Setup IP Address Configuration section in the Owner s Manual for details on determining the KVMs IP address 2 A screen will appear asking you to provide a username and password Note If you are first prompted by a screen that says the website s security certificate cannot be trusted click on the link to proceed anyway the certificate can be trusted 6022 U08 IP Login TRIPPLITE Copyright 2012 Tripp Lite Al rights reserved Al trademarks are the property of their res
17. dard Rack Mounting 1 Depending on whether you want to mount the KVM switch to the front or back of the rack attach the included rackmount brackets to the front or rear sides of the KVM switch 2 Using user supplied screws mount the rackmount brackets of the KVM switch to the rack 5 3 Grounding To prevent damage to your installation it is important that all devices are properly grounded Using a user supplied grounding wire ground the KVM switch by connecting one end of the wire to the grounding terminal on the unit and the other end of the wire to a suitably grounded object 5 4 Single Stage Installation In a single stage installation there are no additional KVM switches daisy chained from the master KVM To set up a single stage installation refer to the following steps and installation diagram TRIPP LITE ie IF ROA e W o cap denmp demo Eo dem demr demp demp as g 7 g 5 4 3 2 7 LAN CHAI IN OUT CON OLE z Q TRIPPLITE ee El Power OFF all computers that are being connected to the KVM switch FA Add an external console to the KVM by connecting the included USB PS2 console cable kit to the console port on the back of the unit and then connecting an external monitor HD15 keyboard USB or PS 2 and mouse USB or PS 2 to the connectors on the cable kit Con
18. ded with the next stage KVM switch and plug it into a Tripp Lite Surge Suppressor PDU or Uninterruptible Power Supply UPS The Station ID on the KVM s front panel will display 02 E Repeat step 7 for each subsequent KVM switch in the installation In each case wait for the previous KVM switches Station ID to be displayed before connecting the power cord to the next KVM switch E Power ON the connected computers When connecting to computers using the PS 2 connectors of a P778 Series Cable Kit the Mouse Sync Mode setting must be set to Manual in order to access the computer over IP If Mouse Sync Mode is set to Automatic you will not have mouse functionality when accessing that computer over IP This setting is set to Manual by default In order to configure a fixed IP address you will need to access the KVM switch in one of four ways Local Console IP Installer Browser or Non Browser Clients 5 6 1 Local Console Note The local console OSD only allows you to configure IPv4 network settings For IPv6 access the Web Management Interface or Remote Session OSD 1 When accessing the KVM switch for the first time a prompt will appear asking for a Username and Password The default Username is administrator and the default Password is password For security purposes it is strongly recommended that you change the username and password on this account to something unique When you have entered your username and password the
19. ected computer try the following methods to help synchronize the local and remote mouse pointers Note Mouse synchronization may require several seconds to take effect Wait 15 to 30 seconds to ensure that the mouse has had enough time to sync e Perform a Video Auto Sync by clicking on the Video Auto Sync icon in the control panel or by opening up the Video Settings screen and clicking on the Auto Sync button In most cases the local and remote mouse pointers will automatically align following the Video Auto Sync e Move the mouse pointer into all four corners of the screen in any order Invoke the Adjust Mouse hotkey command see the Remote Control Panel section in the Owner s Manual for details This hotkey command defaults at Alt M and will bring the local and remote mouse pointers together e If mouse and keyboard response time is slow and choppy adjusting the video settings can help The less data that is being sent over the network the faster the mouse and keyboard response time In particular adjustment of the Quality and Color Depth Control settings in the Video Settings screen can help decrease the amount of data being transferred e Go to the Display Settings in the computer connected to the KVM and decrease the Screen Resolution and Color Quality settings 7 Warranty Registration WARRANTY REGISTRATION Visit www tripplite com warranty today to register the 1 year limited warranty for your new Tripp
20. erial number can be found on the CD that comes with the KVM Key in the serial number 5 characters per box then click OK Serial Mumber 3 Upon entering the serial number the AP Java Client connect prompt appears asking you to enter in the ZP address and Port of the KVM you wish to connect to Enter in this information and click the Connect button Note The default port number assigned to the KVM is 9000 192 168 0 60 e000 cel x Server Pork 6 4 Web Browser and Non Browser Remote Port Access When accessing the KVM switch over IP the connected computers can be accessed using either Windows or Java applications Regardless of which application you use or whether you log in via browser or AP client operation of the KVM switch is the same the only difference is in how you login and connect to the KVM When logging in via the AP Windows and Java clients you are brought directly to the connected computers and the Remote OSD is displayed When logging in via web browser you are brought to the Web Management Interface which includes Windows Client and Java Applet applications for accessing the connected computers Those who login using Internet Explorer will be able to access both the Windows Client and Java Applet whereas users who login using another browser only have access to the Java Applet Once logged into the web interface via browser click on the Windows Client or Java Applet icon to open the applications
21. es together for organizational purposes El USB Peripheral Port A USB 1 1 port is provided for the sharing of USB peripherals among connected computers e g flash drive CD ROM drive etc Note USB peripherals can only be shared among computers that are connected to the KVM switch via the USB connectors on the P778 Series USB PS2 Combo KVM Cable Kit Firmware Upgrade Switch During a firmware upgrade as well as normal operation this switch should be in the NORMAL position If a firmware upgrade does not perform successfully this switch is flipped to the RECOVER position during the firmware upgrade recovery process Firmware Upgrade Port The RJ11 connector on the included firmware upgrade cable connects to the KVM switch here Power LED The Power LED illuminates blue to indicate the unit is receiving power Station ID LED The Station ID LED will display the number of the station that currently has the console s focus Power Jack The included power supply connects to the KVM here LAN Port The cable that connects the KVM switch to a LAN WAN or Internet plugs in here Console Port The included USB PS2 Combo Console Cable Kit connects to the KVM switch here allowing you to attach a VGA monitor and USB or PS 2 keyboard mouse 5 Installation e Ifthe following conditions occur unplug the device from the wall outlet and bring it to qualified service personnel for repair 5 1 General Safety Instructions
22. gerous voltage points or short out parts resulting in a risk of fire or electrical shock Do not attempt to service the device yourself Refer all servicing to qualified service personnel e The power cord or plug has become damaged or frayed e Liquid has been spilled into the device e The device has been exposed to rain or water e The device has been dropped or the cabinet has been damaged e The device exhibits a distinct change in performance indicating a need for service e The device does not operate normally when the operating instructions are followed e Only adjust those controls that are covered in the operating instructions Improper adjustment of other controls may result in damage that will require extensive work by a qualified technician to repair e Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Rack Mounting Safety Instructions e The ambient operating temperature in the rack may be an issue and is dependent upon the rack load and ventilation When installing in a closed or multi unit rack assembly make sure that the temperature will not exceed the maximum rated ambient temperature e Before working on the rack make
23. n the Web Management From here a fixed IP address can be assigned in the same way as Interface but it is presented in a different format when using a web browser See steps 5 through 8 in the Browser section Han Configuranon Admrastraton r Man Condigurabon Administ sson m a ren big Lal rTP CESS pi04 pete D pirg Pra Configuration piw Obtain an IF sidem sutomacaly Deir see B Set F address maway Fooed F BP Acinic id i Tukan haak as JPF ad Definit ary ji ies D pat Ore aren bideti mara Prefered DHE pervert dt Bee ee OS a fa ie Pvt Configurer G Dita at JF acres mibe CHF Tel DP aditi marua Paced IF F hidep Prot Leng Tie fadt Ge bey Obten GAG pmet pider mioa bat ORE uivi biai mally Prefered DHS serve terete ONS pereer 6 KVM Operation 6 1 Local Console Login When accessing the console KVM switch for the first time a prompt FH GOTO FSET will appear asking for a username and password The default username F2 LIST Fas Divi is administrator and the default password is password For security T purposes it is strongly recommended that you change the username and SN PH ov x password on this account to something unique Once the KVM has been set up and user accounts have been created the login prompt will only appear when a user logs out of the KVM When you have entered your username and password the OSD will appear with the following page displayed
24. nect a P778 Series USB PS2 Combo KVM Cable Kit between an available KVM port on the back of the unit and a computer server P778 Series Cable Kits allow you to connect to a computer with either USB or PS 2 keyboard mouse ports without the need for separate cables Note The distance between the KVM and the connected computer must not exceed 33 ft 10 m El Repeat step 3 for each additional computer you wish to connect E Connect the LAN port on the back of the unit to the network using Cat5e 6 cable A Connect the included external power supply to the BO22 U08 IP and then plug it into a Tripp Lite Surge Suppressor PDU or Uninterruptible Power Supply UPS After the KVM switch powers up power on the connected computers When connecting to computers using the PS 2 connectors of a P778 Series Cable Kit the Mouse Sync Mode setting must be set to Manual in order to access the computer over IP If Mouse Sync Mode is set to Automatic you will not have mouse functionality when accessing that computer over IP This setting is set to Manual by default 5 Installation continued 5 5 Multi Stage Daisy chain Installation The number of connected computers can be increased by daisy chaining additional B022 016 or B022 U16 KVM Switches An additional 15 KVM switches can be added for a total of 248 connected computers B022 U08 IP p d aap aap gt Esp aap p m B022 016 or B022 U16 B022 016 or
25. nufacturer The manufacturer makes no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose Any of the manufacturer s software described in this manual is sold or licensed as 1s Should the programs prove defective following their purchase the buyer and not the manufacturer its distributor or its dealer assumes the entire cost of all necessary servicing repair and any incidental or consequential damages resulting from any defect in the software The manufacturer of this system is not responsible for any radio and or TV interference caused by unauthorized modifications to this device It is the responsibility of the user to correct such interference The manufacturer is not responsible for any damage incurred in the operation of this system if the correct operational voltage setting was not selected prior to operation PLEASE VERIFY THAT THE VOLTAGE SETTING IS CORRECT BEFORE USE 3 Package Contents This package consists of e B022 U08 IP KVM Switch e External Power Supply e 6 ft USB PS2 Combo KVM Cable Kits x2 e Rubber Feet e USB PS2 Combo Console Cable Kit e CD with Owner s Manual Quick Start Guide and Device Files e RJ11 to DB9 Firmware Upgrade Cable e Quick Start Guide e Rackmount Hardware Check to make sure that all of the components are present and in good order If anything i
26. o obtain and edit the IP address your device doesn t appear click the Enumerate button to refresh the assigned to the KVM To use the ZP Installer utility the computer you Device List Zf there is more than one device in the list use the MAC are using must be running a Windows operating system and must be on address on the bottom of your unit to determine the desired device the same network as the KVM Also the ZP Installer setting in the Network page of the Web Management Interface must be set to Enabled which it is by default 4 To assign a fixed IP address check the Use the following IP address checkbox and fill in the JP Address Subnet Mask and Default Gateway fields with information appropriate for your network Note The IP Installer settings can only be accessed via the browser IPv4 or IPv6 based Web Management Interface They are not accessible in the Remote OSD l 5 Click the Set IP button to apply the changes to the unit The new IP address will appear in the Device List Save the ZP Installer exe file from the CD to a desired location on a Click the Exit button t it the ZP Installer utility computer that is on the same network as the KVM 6 Click the Exit button to exit the IP Installer utility Locate the JP Installer exe file that you just saved and double click on it A screen similar to the one below will appear E Network Device IP Installer Device list Model Name MAC Address IP Address
27. olbar e When the remote OSD toolbar is opened you can hit the Scroll Lock key once more to open the remote OSD When the OSD toolbar is not opened hitting the Scroll Lock key three times will open the remote OSD e When the remote OSD toolbar is opened pressing the key will skip to the first accessible port prior to the currently selected port e When the remote OSD toolbar is opened pressing the P key will skip to the first accessible port after the currently selected port e When the remote OSD toolbar is opened pressing the f key will skip to the first accessible port in the entire installation e When the remote OSD toolbar is opened pressing the Ww key will skip to the last accessible port in the entire installation 14 B020 U08 19 IP WinClient ersion 1 0 091 Main Configuration Administration All sh 01 08 o 01 02 01 03 01 04 01 05 01 06 01 07 01 08 This table describes the icons in the remote OSD toolbar Ilcon Description ra Skips to the last accessible port in the KVM station prior to the currently selected station y Skips to the first accessible port in the KVM station after the i currently selected station Skips to the first accessible port in the entire installation 4 Skips to the first accessible port prior to the currently selected port Initiates an auto scan pe Skips to the first accessible
28. pective owners 6 3 2 Logging In via the AP Windows Client In the event you do not want to connect to the KVM switch via web browser you can use the AP Windows Client located on the CD to provide non browser access to the KVM switch via a Windows computer Note The AP Windows Client requires that DirectX 8 0 or higher be installed on your computer 1 Save the AP Windows Client from the CD to a desired location on your Windows computer 2 Double click on the file and follow the installation instructions that follow 3 When the installation is complete an icon will be added to your desktop and a program entry will be made in the Windows start menu Start gt All Programs gt BO22 U08 IP Double click on the icon or select the program entry in the start menu to open the AP Windows Client 11 If accessing the KVM for the first time enter in the username administrator and the password password For security purposes it is strongly recommended that you change the username and password on this account to something unique When you have entered your username and password the KVM web interface will appear with the following page displayed B022 U08 IP Q Open Java Chent Log s Apply di i i 5 Logout TRIPPLITE Copyright 2012 Tripp Lite Al rights reserved Al trademarks are the property of their respective owners 4 If this is the first time that you are running the utility a dialog box
29. port after the currently selected port C Skips to the last accessible port in the entire installation TH Opens the remote OSD Invokes Panel Array Mode Closes the remote OSD toolbar Closes out of the remote session 6 KVM Operation continued 6 4 3 Mouse Synchronization When accessing connected computers over IP there are two mouse pointers one for the local computer accessing the KVM and one for the remote computer connected to the KVM When remotely accessing computers connected to the KVM switch a Video Auto Sync is performed at which time the local and remote mouse pointers are automatically aligned If these two mouse pointers do not align properly or if the response time is slow and choppy there are a number of methods to get them synced and working properly Before trying any mouse synchronization procedures it is always a good idea to ensure that you go to your Mouse Properties Settings and set them according to the instructions below The Mouse Properties Settings should be set on the computers attached to the KVM Switch not the computer you are using to access it Windows Note In order for the local and remote mice to synchronize you must use the generic mouse driver supplied with your Windows operating system If you have a third party driver installed such as one supplied by the mouse manufacturer you must remove it Windows 2000 1 Open the Mouse Properties dialog box Control Panel gt Mo
30. r computer Follow the installation prompts that appear Once installed a Windows Client icon will appear on your desktop 3 When accessing either the Windows or the Java client for the first time you will be prompted to enter the product serial number which can be found on the CD that came with the unit Once entered you will not be prompted for it again The non browser client connection screen appears Server List Name IP Address Server IP 12 233 90 229 Remote View Port 9000 5 By default the Obtain IP address automatically DHCP checkbox is checked To set a fixed IP address check the Set IP address manually Fixed IP check box in the IPv4 or IPv6 settings section depending on your network 6 The JP Address Subnet Mask and Default Gateway fields will be activated upon checking the Set IP address manually Fixed IP checkbox Fill in these fields with information appropriate for your network 7 As with the IP Address settings the DNS Server settings can be obtained automatically or assigned manually To manually enter these settings check the Set DNS server address manually checkbox and fill in the Preferred DNS server and Alternate DNS server fields with information appropriate for your network Note The Alternate DNS server field is optional 8 When you have entered the IP Address and DNS Server settings click the Apply button Clicking the Apply button will automatically check the Reset on e
31. r the Waste Electrical and Electronic Equipment WEEE Directive and implementing regulations when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to e Send old equipment for recycling on a one for one like for like basis this varies depending on the country e Send the new equipment back for recycling when this ultimately becomes waste Warning Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended Do not use this equipment in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Tripp Lite follows a policy of continuous improvement Product specifications are subject to change without notice TRIPPLITE Excellence 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 12 12 022 93327A_RevA 16
32. s missing or was damaged in shipping contact your dealer Read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the switch or to any other devices in the installation 4 Introduction VAN 4 1 Features e IU Rackmount KVM Switch with built in IP access e Connect either USB or PS 2 computers using P778 Series USB PS2 Combo KVM Cable Kits no need for separate cable kits e Control up to 8 computers on a single KVM switch e Daisychain multiple KVM switches together to increase the number of connected computers An additional 15 KVM switches can be daisychained from the BO22 U08 IP for a total of 248 connected computers e Remotely access computers via LAN WAN or Internet via the Windows or Java browser clients e AP Windows and Java Clients allow the KVM to be remotely accessed via the network without going through a browser e External USB 1 1 port allows USB peripheral devices to be shared amongst connected computers e Grayscale feature allows you to view remote sessions in black and white reducing the amount of data traveling over the network and improving keyboard mouse response time over IP e Web management interface OSD and toolbars provide convenient user friendly operation e 3 level security Admin User and Select up to 64 accounts can be created e Panel Array Mode remotely monitor multiple ports at the same time e Message board feature allo
33. the main screen become active Click on the Remote View button to remotely connect to the KVM switch Eloi x Server List Name TP Address Remote view Change Password 9000 m 9 Upon clicking on the Remote View button the screen of the first connected computer on the installation that you have access to is displayed as well as the Remote OSD 68 20 227 45 BO20 U08 19 IP JavaClient ersion 1 0 093 Hide 01 08 01 02 01 03 01 04 01 05 01 06 01 07 01 08 MSN Installer HyperTerminal u088 Internet ESEI ee EA E adsa E 2 start Eua oid Bo20 T Bozo W Bo20 22 eoz0 Z s3290 93284 m B020 B020 Z eoz0 w B020 ee 68 20 23 3 31PM 6 KVM Operation continued 6 3 3 Logging In via the AP Java Client Computers not running Windows can use the AP Java Client located on the CD to provide non browser access to the KVM switch Note The AP Java Client requires that the Java Runtime Environment JRE be installed on your computer The JRE is available for free download from the Java web site http java com 1 Save the AP Java Client from the CD to a desired location on your computer 2 Double click on the file you just saved If this is the first time that you are running the utility a dialog box appears requesting you to input your serial number The s
34. use gt Mouse Properties Click the Motion tab Set the mouse speed to the middle position 6 units in from the left Set the mouse acceleration to None Mouse Properties f Buttons Pointers Motion Hardware Acceleration Adjust how much your pointer accelerates as you move it faster 6 Snap to default fC Low Medium C High Ld Move pointer to the default button in dialog boxes Windows XP Server 2003 Vista 7 1 Open the Mouse Properties dialog box Control Panel gt Mouse 2 Click the Pointer Options tab 3 Set the mouse speed to the middle position 6 units in from the left 4 Disable Enhance Pointer Precision 15 Mouse Properties Buttons Pointers Pointer Options Whee Hardware Motion Snap To Automatically move pointer to the default button in a a dialog box Visibility No Display pointer trails i gt Z Hide pointer while typing LI Show location of pointer when press the CTRL key Windows ME e Set the mouse speed to the middle position and disable mouse acceleration Click the Advanced button to get the dialog box for this Windows NT Windows 98 Windows 95 e Set the mouse speed to the slowest position Sun Linux Open a terminal session and issue the following command Sun xset m Linux xset m 0 Mouse Synchronization Procedures If you are having syncing problems after adjusting the mouse properties of the conn
35. ws users who are logged in at the same time to communicate with each other and manage port access e CD includes a Windows based log server that records events on the installation and writes them to a searchable database e Supports RADIUS and LDAP S authentication e Flash firmware upgradable via network and included firmware upgrade cable e Supports both IPv4 and IPv6 e Supports Link Local IPv6 Address and IPv6 Stateless Auto configuration protocol e Web Management Interface Remote OSD and Local OSD can be displayed in English Spanish French German and Japanese e Advanced encryption technologies 128 bit SSL 128 bit RC4 1024 bit RSA 56 bit DES 256 bit AES 168 bit 3DES e Video resolutions up to 2048 x 1536 DDC2B are supported at the local console Video resolutions up to 1600 x 1200 60Hz 24 bit color depth are supported at the remote console 2 4 Introduction continued 4 2 System Requirements 4 2 1 External Console e A VGA SVGA or MultiSync monitor capable of displaying the highest resolution provided by any computer in the installation e PS 2 or USB keyboard and mouse 4 2 2 Computers The following equipment must be installed on each computer e A VGA SVGA or MultiSync video graphics card with an HD15 port Either e PS 2 mouse and keyboard ports 6 pin Mini DIN e USB port 4 2 4 Supported Browsers Browser Internet Explorer Firefox Mozilla Safari Opera Netscape 4 2 5 Custom KVM C
36. xit checkbox located in the Customization page of the Web Management Interface When you log out the unit will be reset and your network changes will be applied See the Network Settings section in the Owner s Manual for complete information on the rest of the settings in this page 4 If you are on the same network as the KVM the client will locate it and display it in the Device List In this case highlight the unit in the Device List and click the Login button If you are not on the same network as the unit it will not be displayed in the list You must manually enter the IP address in the IP Address field and then click the Login button 5 Upon clicking the Login button you will be prompted to enter in a Username and Password Enter the default User Name administrator and the default Password password The Logout button and the Remote View and Change Password buttons on the right of the non browser client main page will be activated The Login button will be deactivated Server List Name IP Address Server IP 12 233 90 229 Port 9000 5 Installation continued 5 6 4 Non Browser Clients continued 6 Click the Remote View button to initiate a remote session which will 7 Click on the Administration tab at the top of the screen On this open with the remote OSD displayed The remote OSD contains page click on the Network Icon amp to pull up the Network page most of the features that are contained i

Download Pdf Manuals

image

Related Search

Related Contents

Samsung S690 User Manual  www.nintendo.com  WT-02 取扱説明書ダウンロード(1.23MB  Fisher & Paykel DD24DTI7 User's Manual  Haier HGN-36100EB User's Manual  T'nB ETDCPULLC  ASUS N550JK C7914 User's Manual  Hardware Guide.fm  2N OMEGA Lite - Operator services LŠ 1486v1.0  Manuel de l`utilisateur friteuse a gaz frymaster  