Home
Transition Networks CPSMP-120 User's Manual
Contents
1. Disconnect the the male end of the AC power cord from the AC rack or wall socket Disconnect the female end of the AC power cord from the external power connector On Off Power Switch LED From the inside edge of the power receptacle insert a small flat blade screwdriver into the groove on the front inside edge of the fuse holder and carefully pry the fuse holder from the power supply module Carefully remove the fuse from the fuse holder Install a same size and rating replacement fuse in the fuse holder Return the fuse holder and fuse to the installation position in the power supply module Snap the fuse holder into place See the Connect to External Power section page 4 for instructions on re connecting the power supply module to the external power source techsupport transition com Click the Transition Now link for a live Web chat 7 CPSMP 120 Technical Specification For use with Transition Networks Model CPSMP 120 or equivalent Standards UL Listed FCC amp CISPR Class A CE Mark Dimensions 3 4 x 2 5 x 11 0 86 mm x 64 mm x 279 mm Weight 1 8 lb 0 82 kg approximate Power Input 100 240 V 50 60Hz 0 4 to 1 0 Amp Power Output typical with a fully loaded chassis 12VDC at 10 83 Amp maximum Fuse 4 Amp 250V MTBF 220 000 hours MIL217F2 V5 0 MIL HDBK 21 7F 538 224 hours Bellcore7 V5 0 Environment Tmra 0 to 50 C 32 to 122 F
2. Storage Temp 20 to 85 C 4 to 185 F Humidity 10 to 90 non condensing Altitude 0 to 10 000 feet Warranty Lifetime Manufacturer s rated ambient temperature Tmra range for this power supply module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem chassis in which this power supply will be installed For the most up to date information on the CPSMP 120 power supply module view the user s guide on line at www transition com Troubleshooting If the power supply module fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the power LED on the CPSMP 120 power supply module illuminated NO e Is the power supply module inserted properly into the chassis e Is the power supply module properly connected to the external power source e Does the external power source provide power e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES e Proceed to step 2 Is the fuse on the CPSMP 120 power supply intact NO e CAUTION See the Replace the Fuse section page 7 for the proper method for replacing the fuse to the CPSMP 120 power supply module e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 YES e Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7
3. 600 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 9 CPSMP 120 Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 TRANSTTION DECLARATION OF CONFORMITY Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model CPSMP 120 Redundant Power Supply 120 240 VAC Part Number s CPSMP 120 Regulation EMC Directive 89 336 EEC Purpose To declare that the CPSMP 120 to which this declaration refers is in conformity with the following standards EN 55022 1998 A1 2000 Class A EN 55024 1998 FCC Part 15 Subpart B UL 1950 EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 21CFR Subpart J l the undersigned hereby declare that the equipment specifie
4. TRAN Pe ee a networks User s Guide CPSMP 120 AC Power Supply Module e PointSystem e CPSMC13xx 100 Accessory The Transition Networks CPSMP 120 power supply is an AC slide in module that provides optional redundant power to the CPSMC13xx 100 PointSystem 13 slot chassis and any installed media converter slide in modules and management modules The figure below illustrates the components of the CPSMP 120 power supply e An On Off switch that when set to I allows the power supply module to supply power to the chassis and any installed modules e A panel fastener screw that secures the power supply module to the chassis e A power LED indicator e A handle for installing and removing the power supply module to from the chassis e A fuse installed in a fuse holder e An external power connector that supplies power from a standard AC wall outlet On Off Switch e Panel Fastener Screw a Power LED Handle Fuse Holder External Power Connector Install the CPSMP 120 3 Connect to External Power 4 Replace the CPSMP 120 5 Replace the Fuse 7 Technical Specifications 8 Troubleshooting 9 Compliance Information 11 CPSMP 120 CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing or servicing the power supply module Failure to obser
5. d above conforms to the above Directive s and Standard s Pa Oe I Oe une 8 2001 Stephen Anderson Vice President of Engineering Date 10 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Compliance Information UL Listed C UL Listed Canada CISPR22 EN55022 Class A CE Mark1 FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Co
6. ide the power supply module to be replaced out of the chassis techsupport transition com Click the Transition Now link for a live Web chat 5 CPSMP 120 Replace the CPSMP 120 Continued 6 Carefully slide the replacement power supply module into the installation slot aligning the module with the installation guides Fastener Screw Ensure that the power supply module is firmly seated inside the chassis Rotate the attached panel fastener screw clockwise to secure the power supply module to the chassis 9 See the Connect to External Power section page 4 for instructions on re connecting the power supply module to the external power source 6 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Replace the Fuse CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution could result in damage to and subsequent failure of the power supply module NOTE The CPSMP 120 power supply module may be hot swapped i e serviced while the chassis is in operation provided the module to be serviced has been disconnected from its external power supply and the module s On Off switch has been set to 0 To replace the fuse in the CPSMP 120 power supply module 1 2 Ensure the On Off switch on the power supply module is set to 0
7. male end of the AC power cord to the male end of the external power connector 3 Connect the male end of the AC power cord into the correct voltage AC rack or wall socket 4 Set the power supply module power switch to I 5 Verify that the CPSMP 120 power supply module is powered by observing the illuminated power LED Panel Fastener Screw Power LED On Off Switch External Power Connector AC Power Cord 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Replace the CPSMP 120 CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution could result in damage to and subsequent failure of the power supply module NOTE The CPSMP 120 power supply module may be hot swapped i e replaced while the chassis is in operation provided the module to be replaced has been disconnected from its external power source and the module s On Off switch has been set to 0 To replace the CPSMP 120 power supply module Ensure the On Off switch on the power supply module is set to 0 2 Disconnect the the male end of the AC power cord from the AC rack or wall socket 3 Disconnect the female end of the AC power cord from the external power connector 4 Rotate the attached panel fastener screw counter clockwise Fastener Screw 5 Carefully sl
8. mmunications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten in weichen Fallen der Benutzer f r entsprechende Gegenma nahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques appropri es techsupport transition com Click the Transition Now link for a live Web chat 11 Trademark Notice All trademarks and registered trademarks are the property of their respective owners Copyright Restrictions 2001 2004 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33209 C
9. provided the module to be installed has been disconnected from its external power source and the module s On Off switch has been set to 0 To install the CPSMP 120 power supply module into the CPSMC13xx 100 chassis 1 Loosen the screw that secures the protective plate to the chassis and pull the plate away from the chassis 2 Ensure the On Off switch on the power supply module is set to 0 Carefully slide the power supply module into the installation slot aligning the module with the installation guides Fastener Screw 4 Ensure that the power supply module is firmly seated inside the chassis 5 Rotate the attached panel fastener screw clockwise to secure the power supply module to the chassis techsupport transition com Click the Transition Now link for a live Web chat 3 CPSMP 120 WARNING Do not connect the power supply module to the external power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or death Connect to External Power CAUTION Ensure that the On Off switch on the power supply module is set to 0 when connecting to the external power source Failure to observe this caution could result in damage to and subsequent failure of the power supply module To power the CPSMP 120 power supply module 1 Set the On Off switch on the power supply module to 0 2 Connect the fe
10. ve this caution could result in damage to and subsequent failure of the power supply module CPSMP 120 in the 13 Slot Chassis The CPSMP 120 power supply module may replace an existing CPSMP 120 module or be installed in the second installation slot see drawing below of the CPSMC1300 100 13 slot chassis to become the optional redundant power supply AC Power Second Supply Installation Slot NOTE The CPSMP 120 power supply module may also be installed as the redundant power supply in either DC powered 13 slot chassis e CPSMC1310 100 48 VDC chassis e CPSMC1320 100 24 VDC chassis For more information see the user s guide for the CPSMC13xx 100 13 slot chassis on line at www transition com 2 24 hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 WARNING Do not connect the power supply module to the external power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or death Install the CPSMP 120 CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution could result in damage to and subsequent failure of the power supply module NOTE The CPSMP 120 power supply module may be hot swapped i e installed in the chassis while the chassis is in operation
Download Pdf Manuals
Related Search
Related Contents
American Standard M962428-YYY0A User's Manual HARBOR-UCLA MEDICAL CENTER Department of Nursing User Manual BE60GL 60 cm Glass chimney hood Moisture analyzer MAC series Port Designs MONZA Irby Tool & Safety Descarga aquí la ficha técnica de este producto SMA BLUETOOTH® REPEATER - Installation Manual Copyright © All rights reserved.