1. DOWN Disables Auto Negotiation on the copper port 2 Copper Mode Applies only if switch 1 is DOWN UP Forces full duplex operation on the copper port DOWN Forces half duplex operation on the copper port 3 Speed Applies only if switch 1 is DOWN UP Forces 100 Mb s operation on the copper port DOWN Forces 10 Mb s operation on the copper port 4 Fiber Mode UP Forces full duplex operation on the fiber port DOWN Forces half duplex operation on the fiber port 2 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 INSTALLATION Continued Set the Jumpers The jumpers are located on the Media Converter circuit board Use small needle nosed pliers or a similar device to set the jumper The Hardware Software jumper is labeled H for hardware and S for software see the drawing below s oG Hardware The Media Converter mode is determined by ERETTE the 4 position switch settings listed above Software The Media Converter mode is determined by eNe H the most recently saved on board microprocessor settings Software Mode The Far End Fault jumper is labeled FE for enable Far End Fault and FD for disable Far End Fault see the drawing below Rao Fp Enable A fault on the fiber link causes the Media Enable Far End Fault Converter to transmit a Far End Fault signal Disable No Far End Fault signal is transmitted when a fault occurs FE ome FD Disab
2. AWG 11 5 dB 100m 5 10 MHz Category 5 REQUIRED for 100 Mb s operation 24 to 22 AWG 22 0 dB 100m 100 MHz e Straight Through Twisted Pair cable must be used Fiber Cable Standards IEEE 802 3 Bit Error Rate lt 10 9 Data Rate 10 Mb s 100 Mb s Singlemode fiber recommended 9 um i P Multimode fiber recommended 62 5 125 pm Dimensions 3 4 x 4 7 x 0 87 86 mm x 119 mm x 22 mm Multimode fiber optional 100 140 85 140 50 125 um Weight 4 oz 114 g approximate CBFTF1011 150 CBFTF1013 150 multimode Power Consumption 4 0 W Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 14 0 dBm MTBF 629 677 hours MIL217F2 V5 0 MIL HDBK 217F Link Budget 11 0 dB 1 630 181 hours Bellcore7 V5 0 CBFTF1014 150 singlemode Packet Size Unicast MAC address 128K bytes 1 Mbit Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Maximum packet size 1522 bytes Fiber optic Receiver Sensitivity min 31 0 dBm max 8 0 dBm Memorv 1K bytes l y y Link Budget 16 0 dB nee oel 4 Environment Tmra O to 60 C 32 to 140 F singiemode e Fiber optic Transmitter Power min 8 0 dBm max 2 0 dBm ta von oe ak o Fiber optic Receiver Sensitivity min 34 0 dBm max 7 0 dBm A Hy E EEEE Link Budget 26 0 dB Altitude 0 1 0 000 feet CBFTF1018 150 multimode Warranty Lifetime sedi ee Power Ta 19 0 au a bee ae Manufacturer s rated ambient tempera
3. If the result is less than or equal to 512 BT the path is good For more information on the 512 Bit Rule see the white paper titled Collision Domains on the Transition Networks website at http www transition com learning whitepapers colldom_wp htm Using SNMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SNMP at an attached terminal or at a remote location to monitor the Media Converter by monitoring e Media Converter power e Copper and fiber link status e Copper and fiber duplex mode e Copper port speed e Hardware switch setting Also use SNMP to enter network commands that e Enable disable Auto Negotiation on Copper e Force 10Mb s or 100Mb s on copper e Force full duplex or half duplex on copper e Force full duplex or half duplex on fiber e Enable disable Far End Fault on fiber 6 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 techsupport transition com Select the Transition Now Link for a Live Web Chat 7 CBFTF10xx 15x CABLE SPECIFICATIONS The physical characteristics must meet or exceed IEEE 802 3 specifications TECHNICAL SPECIFICATIONS For use with Transition Networks Model CBFTF10xx 15x or equivalent Copper Cable Maximum Cable Distance 100 meters Category 3 May be used for 10 Mb s operation Gauge Attenuation Gauge Attenuation 24 to 22
4. an ein Offentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstdsst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformitat Trademark Notice All trademarks and registered trademarks are the property of their respective owners Copyright Restrictions 2002 2003 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33226 B
5. is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la class A prescrites dans le Reglement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkstorgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkstorungen auftreten in weichen Fallen der Benutzer f r entsprechende Gegenmafsnahmen werantwortlich ist Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors a I utilsateur de prende les measures sp cifiques appropri es CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes
6. 16 6 8 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 techsupport transition com Select the Transition Now Link for a Live Web Chat 9 CBFTF10xx 15x FAULT ISOLATION AND RECOVERY If the Media Converter fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the power LED on the Media Converter illuminated NO e s the media converter inserted properly into the chassis e Is the power cord properly installed in the chassis and at the external power source and does the external power source provide power e Contact Technical Support US Canada 1 800 260 1312 International OO 1 952 941 7600 YES e Proceed to step 2 Is the TLNK twisted pair link LED illuminated NO e Check the copper cables for proper connection and pin assignment e Contact Technical Support US Canada 1 800 260 1312 International O0 1 952 941 7600 YES e Proceed to step 3 Is the FLNK fiber pair link LED illuminated NO e Check the fiber cables for proper connection e Verify that the TX and RX cables are connected to the RX and TX ports respectively on the 100Base FX device e Contact Technical Support US Canada 1 800 260 1312 International O0O 1 952 941 7600 YES e Proceed to step 4 Is the TSPD twisted pair speed LED illuminated NO e Check the copper cables for proper connection e
7. 55344 USA Model CBFTF10xx 15x Series Media Converters Part Number s CBFTF1011 150 CBFTF1013 150 CBFTF1014 150 CBFTF1015 150 CBFTF1018 150 CBFTF1029 150 CBFIF1029 151 CBFTF1029 152 CBFTF1029 153 Regulation EMC Directive 89 336 EEC Purpose To declare that the CBFTF10xx 15x to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 801 3 and 801 4 IEC 950 22 CFR subpart J the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s ee ee Ee August 8 2002 Stephen Anderson Vice President of Engineering Date techsupport transition com Select the Transition Now Link for a Live Web Chat 11 COMPLIANCE INFORMATION UL Listed C UL Listed Canada CISPR22 EN55022 Class A CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area
8. Off The Media Converter has selected 10Mb s operation e If the speed is not correct disconnect and reconnect the twisted pair cable to restart the initialization process e Contact Technical Support US Canada 1 800 260 1312 International OO 1 952 941 7600 e On The Media Converter has selected 100Mb s operation e If the speed is not correct disconnect and reconnect the twisted pair cable to restart the initialization process e Contact Technical Support US Canada 1 800 260 1312 International O0O 1 952 941 7600 10 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 CONTACT US Technical Support Technical support is avialable 7 00 AM 6 00 PM CST GMT 6 00 US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 DECLARATION OF CONFORMITY oe aves Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN
9. TRANSITION Nees networks USER S GUIDE CBFTF10xx 15x Slide in Module Media Converter e Copper to Fiber e 10 100 Bridging 2 Port e 10Base T 100Base TX to 100Base FX The CBFTF10xx 15x 2 port Ethernet Fast Ethernet bridging Media Converter is designed to be installed in a Transition Networks PointSystem chassis and connects 10Base T Ethernet or 100Base TX Fast Ethernet twisted pair copper network devices to network devices on a 100Base FX Fast Ethernet fiber network Part Number Port One Copper 10Base T 100Base TX CBFTF1011 150 RJ 45 100 m 328 ft CBFTF1013 150 RJ 45 100 m 328 ft CBFTF1014 150 RJ 45 100 m 328 ft CBFTF1015 150 RJ 45 100 m 328 ft CBFTF1018 150 RJ 45 100 m 328 ft CBFTF1029 150 RJ 45 100 m 328 ft CBFTF1029 151 R 45 100 m 328 ft CBFTF1029 152 R 45 100 m 328 ft CBFTF1029 153 RJ 45 100 m 328 ft Port Two Duplex Fiber Optic 100Base FX ST 1300 nm multimode 2 km 1 2 miles SC 1300 nm multimode 2 km 1 2 miles SC 1310 nm singlemode 20 km 12 4 miles SC 1310 nm singlemode 40 km 24 8 miles MT RJ 1300 nm multimode 2 km 1 2 miles SC 1310 mn TX 1550 nm RX singlemode 20 km 12 4 miles SC 1550 mn TX 1310 nm RX singlemode 20 km 12 4 miles SC 1310 mn TX 1550 nm RX singlemode 40 km 24 8 miles SC 1550 mn TX 1310 nm RX singlemode 40 km 24 8 miles Typical maximum cabl
10. e distance Actual distance is dependent upon the physical characteristics of the network TX transmit RX receive SBFIF1029 150 and SBFIF1029 151 are intended to be installed in the same network where one is the local converter and the other is the remote converter SBFTF1029 152 and SBFIF1029 153 are intended to be installed in the same network where one is the ocal converter and the other is the remote converter Halan seic a oat ame eaaet 2 OPTA aeaaea a 5 Cable Specifications 8 Technical Specifications 9 Fault Isolation and Correction 10 Compliance Information 12 CBFTF10xx 15x INSTALLATION CAUTION Wear a grounding device and observe electrostatic discharge precautions when setting the 4 position switch and the jumper s and when installing the Slide in Module Failure to observe this caution could result in damage to and subsequent failure of the Media Converter Set the 4 Position Switch Auto Negotiation UP Enabled The 4 position switch is located on the ie side of the Media Converter Use a Speed UP 100Mb s small flatblade screwdriver or a similar Fiber Mode device to set the recessed switches Te om UP Full Duplex Refer to the drawing for the locations of the four individual switches 1 Auto Negotiation UP Enables Auto Negotiation on the copper port Advertises 100 Mb s full duplex and half duplex and 10 Mb s full duplex and half duplex
11. figuration This feature does not require operator intervention Far End Fault When the Far End Fault feature is activated a fault on an incoming fiber link causes the Media Converter to transmit a Far End Fault signal on the outgoing fiber link In addition the Far End Fault signal also activates the Link Pass Through which in turn disables the link on the copper portion of the network _ r S Da Copper Fiber Copper aarti En Sends a Far End we te Fault Media Converter ee ee Sends a Far End ee es Fault 100Base TX ab C 100Base FX Device et CRE a Device ooa ee Media Converter Media Converter Sie ee ee ee OPERATION Continued Product Features Continued Full Duplex Network In a full duplex network maximum cable lengths are determined by the type of cables that are used See page 1 front cover for the cable specifications for the different CBFTF10xx 15x models The 512 Bit Rule does not apply in a full duplex network Half Duplex Network 512 Bit Rule In a half duplex network the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e g a terminal switch or router The 512 Bit Rule determines the maximum length of cable permitted by calculating the round trip delay in bit times BT of a particular collision domain
12. le Far End Fault Installing the Slide In Module CAUTION Slots in the PointSystem Chassis without a Slide in Module installed MUST have a protective plate covering the empty slot for Class A and or Class B compliance To install the CGETF10xx 15x Media Converter Slide in Module 1 Locate an empty installation slot on the PointSystem Chassis 2 Carefully slide the Slide in Module into the installation slot aligning the Slide in Module with the installation guides 3 Ensure that the Slide in Module is firmly seated against the back of the chassis 4 Secure the Slide in Module by securing the panel fastener screw attached to the Slide in Module to the chassis front Panel Fastener Screw techsupport transition com Select the Transition Now Link for a Live Web Chat 3 CBFTF10xx 15x INSTALLATION Continued Install the Twisted Pair Copper Cable f Locate or build IEEE 803 2 compliant 10Base T or 100Base TX cables with straight through RJ 45 cable and with straight through RJ 45 connectors installed at both ends Connect the RJ 45 connector at one end of the cable to the RJ 45 port connector on the Media Converter Connect the RJ 45 connector at the other end of the cable to the RJ 45 port connector on the other device switch workstation etc NOTE The MDI straight through or MDI X crossover cable connection is configured automatically according to the netw
13. n to external AC power TSPD Twisted Pair Speed ON 100 Mb s Blinking 10 Mb s TDPX Twisted Pair Duplex ON full duplex copper connection LED off half duplex copper connection TLKN Twisted Pair Link ON copper link connection Blinking copper network activity FDPX FLNK PWR O O TSPD TDPX TLNK x lt XAj ese A001 vs gt lt xl seg00L 0 i CBF TETS0 techsupport transition com Select the Transition Now Link for a Live Web Chat CBFTF10xx 15x OPERATION Continued a ee ee ee a Product Features Auto Negotiation The Auto Negotiation feature allows the Media Converter to be used with 10Base T and 100Base TX twisted pair ports Using Auto Negotiation the Media Converter brings up the copper links in the highest speed and mode possible for all the attached network devices If selected Auto Negotiation allows a twisted pair link to become operational only after the Auto Negotiation function matches network speed capabilities at both ends of the twisted pair copper segment Autocross The AutoCross feature when selected allows either straight through MDI or crossover MDI X cables to be used when connecting to 10Base TX or 100Base TX devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable con
14. ork conditions on the Media RJ 45 port RJ 45 port on the other device switch work station etc Converter Install the Fiber Cable l Locate or build IEEE 803 2 compliant 100Base FX fiber cable with male two stranded TX to RX connectors installed at both ends Connect the fiber cables to the CBFTF10xx 15x Media Converter as described e Connect the male TX cable connector the female TX connector e Connect the male RX cable connector to the female RX connector Connect the fiber cables to the other device another Media Converter hub etc as described e Connect the male TX cable connector the female RX connector e Connect the male RX cable connector to the female TX connector Connect the fiber cable to the other device media converter hub etc as shown Connect the fiber cable to the Media Converter as shown RX TX 4 Tech Support 800 260 1312 International 952 941 7600 7am 6pm CST GMT 6 00 INSTALLATION Continued Power the Media Converter The CBFTF10xx 15x Slide in Module Media Converter is powered through the Point System chassis OPERATION Status LEDs Use the status LEDs to monitor the Media Converter and the network connections FDPX Fiber Duplex ON full duplex fiber connection Blinking half duplex fiber connection FLNK Fiber Link ON fiber link connection Blinking fiber network activity PWR Power ON connectio
15. ture Tmra range for this Slide In Module eee See oes ae aa uu EA depends on the physical characteristics and the installation configuration of the l Transition Networks PointSystem chassis in which this Slide In Module will be CBFTF1029 150 CBFTF1029 151 singlemode installed Fiber optic Transmitter Power min 13 0 dBm max 6 0 dBm Fiber optic Receiver Sensitivity min 32 0 dBm max 3 0 dBm Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Link Budget 19 0 dB Subchapter J applicable at the date of manufacture rae BPTF 1023 193 alge mode l CAUTION Visible and Invisible Laser Radiation When Open Do Not Stare Fiber optic Transmitter Power min 8 0 dBm max 3 0 dBm I B Or View Di lv With Optical Fiber optic Receiver Sensitivity min 33 0 dBm max 3 0 dBm nto Beam Or View Directly With Optical Instruments Link Budget 25 0 dB CAUTION Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure e Shielded Twisted Pair STP OR Unshielded Twisted Pair UTP may be used e Pins 1 amp 2 and 3 amp 6 are the two active pairs in an Ethernet network e Use only dedicated wire pairs for the active pins e g blue white amp white blue orange white amp white orange etc e Do not use flat or silver satin wire Straight Through Cable 1 1 Twisted Pair 1 5 9 Twisted Pair 2

Download Pdf Manuals

image

Related Search

Related Contents

stapile3 - Stewart Technology Associates  Frew Oasys GEO Suite for Windows  取り扱い説明書 GPZ900R / ZEPHYR1100(輸出仕様) 常時  July 2008 - Virus Bulletin  rq 1 - Communauté d`agglomération du Val d`Orge  ASSMANN Electronic DN-19 ORG-47U-SW rack accessory    2003年度 アート・リサーチセンタープロジェクト研究計画書  取扱説明書 ペイントライン引き 品番: 79120100 型式:EST798  here - Steam Vac Australia  