Home

Trane VariTrac Dampers Brochure

image

Contents

1. FRAME Figure 1 Digital Display Zone Sensor Digital Display The digital display zone sensor has the functionality of the full featured Trane DDC zone sensor with a liquid crystal display LCD The zone sensor is compatible with Trane VAV and VariTrac controllers The display can be toggled in the field from zone temperature to zone setpoint and can be viewed in either Fahrenheit or Celsius A communications jack is provided forTrane portable edit terminal devices Additionally the On Cancel buttons allow the system to run in the occupied mode during nighttime operation The ability to override to maximum and minimum airflow or position for field balancing is included in the sensor Please visit trane com or contact a local Trane representative for more information Table 1 Sensor Specifications Zone Sensor Features e LCD Readout of Zone Temperature or Setpoint e Selectable F or C Display e Communication Jack e Occupied Mode Override e Maximum and Minimum Override 2002 American Standard Inc All rights reserved Thermistor Resistance Rating 10k OHM at 77 F 25 C Accuracy at 77 F 25 C 0 4 F 0 2 C Setpoint Resistance Rating 500 Ohms at 70 F 21 2 C Display Zone Temperature Range 40 to 99 F 10 to 35 C Display Setpoint Range 50 to 90 F 10 to 32 C Operating Temperature 0 to 120 F 18 to 49 C Storage Temperature 20 to 1
2. policy of continuous product and product data improvement and reserves the right to change design e mail us at comfort trane com and specifications without notice
3. 30 F 29 to 54 C Humidity Range 5 to 95 non condensing Power Supply 24VAC Maximum VA load 4VA Housing Material Rigid Vinyl Dimensions 4 5 x 2 8 x 1 1 114 mm x 71 mm x 28 mm VAV SLB007 EN Placement of the Sensor AVOID areas such as Table 2 Wiring Terminations at Sensor Choose a mounting location on an e Behind doors interior wall near the return air grille 24VAC Power Supply about five feet above the floor level e On outside walls or walls facing 24V Ground where air circulates freely and is of uncontrolled areas Zone Temperature average temperature for the zone e In direct sunlight or sources of radiant heat that could effect temperature Zone Sensor Ground measurement Zone Setpoint e In line with discharge air from unit being Communication controlled Communication Figure 2 Dimensional Data le 2 8 J 71 mm 4 i ai 3 4 5 mm 114 mm CANCEL Xe J IPE 1 1 ry mE 1 1 28 mm TRANE e U U e E Literature Order Number VAV SLB007 EN File Number SB TD VAV 000 SLB007 EN 0602 Trane An American Standard Company Supersedes New www trane com Stocking Location La Crosse For more information contact your local district office or Trane has a

Download Pdf Manuals

image

Related Search

Related Contents

User`s Manual - EAGLE Technology  Last Updated: dd-Month-yyyy  Termostato control web  König CMP-HEADSET28 headset  User manual Fridge IKE198-0  - Mobiletech Blog  Avaya B159 User's Manual  Product Manual - Lesman Instrument Company  Philo de base  CT-5374 User Manual  

Copyright © All rights reserved.
Failed to retrieve file