1. in first Replace the battery cover by sliding the door into the slots provided in the handle and allow it to snap into place For best performance use quality alkaline batteries Operation Check To verify the operation of the 720b simply turn the unit on and allow it to warm up for approxi mately 1 minute Expose the sensor to a known gas source such as an unlit butane lighter The tick should increase when the gas in applied The tick will decrease when the gas is removed If the unit fails to respond the sensor may need replacing or the unit may need to be sent in for repair CAUTION This unit must be sent to a factory authorized repair center for all repairs Sensor Replacement 1 2 3 4 5 Turn the 720b off Pull off the sensor cap Unplug the old sensor and discard Replace sensor and sensor cap Turn on unit and perform Operation Check Warranty and repair exchange policy Your TPI 720b is warranted to be free from defects in materials and workmanship for a peri od of one year after purchase excluding sensor calibration and batteries If within the warranty period your instrument should become inopera tive from such defects the unit will be repaired or replaced at our option This warranty covers normal use and does not cover damage which results from alteration tampering accident misuse abuse neglect or improper maintenance A purchase receipt or other proof of original date of purchas
2. Combustible Gas Leak Detector 720b The Value Leader pi www tpi thevalueleader com Contents Specifications Product Features Standard Accessories Optional Accessories General Description Operating Instructions Battery Replacement Operation Check Sensor Replacement Warranty Specifications Power Supply 2 C Alkaline Batteries Sensor Solid State Sensitivity 10 ppm Methane Warm up Approx 1 minute Response time Instantaneous Duty Cycle Continuous Battery Life Approx 30 hrs Size 3 0 x 9 5 x 1 75 77 x 240 x 47 mm Weight 1 1 Ibs 500g Probe Length 16 406mm On Off switch Speaker Sensor Visual leak indicator PEE Earphone jack Battery gt Compartment Standard Accessories Sensor A739 Instruction Manual 720b Instruction Manual Soft Pouch A700 Optional Accessories Hard Case A714 Earphone A710 General Description The 720b is an advanced state of the art leak detector capable of detecting many combustible noncombustible and toxic gases The following is a partial list of gases that the 720b is sensitive to Acetone Alcohol Ammonia Steam Carbon Monoxide Butane Gasoline Jet Fuel Hydrogen Sulfide Smoke Industrial Solvents Methane Lacquer Thinner Naphtha Propane Natural Gas Not to be used to quantify the amount of CO present Operating Instructions 1 Turn the unit on in an uncontaminated environment clean air away from the system in quest
3. e will be required before warranty performance will be rendered Instruments out of warranty will be repaired for a service charge Return the unit postpaid and insured to Test Products International Inc 9615 SW Allen Blvd Beaverton OR 97005 503 520 9197 This warranty gives you specific legal rights and you may also have other right which vary from state to state fim The Value Leader www tpi thevalueleader com 750a Instruction Manual Test Products International Inc 9615 SW Allen Blvd Beaverton OR 97005 4814 USA Copyright 2001 Test Products International Inc
4. ion by moving the switch from the OFF position to the ON position The GREEN ready light will illuminate if there is ample battery power The RED LED may flicker and the tick may sound during the warm up To silence the tick rotate the thumb wheel fully counterclockwise Adjust the TICK ADJUST by rotating the thumb wheel in a clockwise direction until a uniform ticking sound is heard The RED light will flash at the same time the tick sounds 4 Approach suspected leak areas with the sensor until the tick begins to increase When the tick increases do not move the sensor from the area rotate the TICK ADJUST slightly counterclock wise to slow the ticking and continue to approach the suspected leak area with the sen sor Continue to slow the tick until the location of the leak is found If the tick stops the con centration level has decreased Move back in the opposite direction to find the leak again If the GREEN LED changes to orange color change the batteries An earphone can be plugged into the earphone jack when using the instrument in noisy environ ments If the instrument does not perform or it has been damaged follow the Operation Check section of this manual Battery Replacement 1 Remove the battery compartment cover from the bottom of the handle by sliding the door away from the front side of the instrument Remove the batteries and replace by sliding the 3 4 negative end of the batteries

Download Pdf Manuals

image

Related Search

Related Contents

CleanOpsStaff-3ed - Hunter Consulting and Training  mode d`emploi du système 04032008 rev 03  Funny Flash  取扱説明書(Verison 6620L)  Accellix User manual  

Copyright © All rights reserved.
Failed to retrieve file