Home

Thermador SB2B User's Manual

image

Contents

1. SECTION I SAFETY PRACTICES TO AVOID PERSONAL INJURY IMPORTANT SAFETY INSTRUCTIONS A READ ALL INSTRUCTIONS BEFORE USING YOUR COOKTOP A LP TANK REQUIREMENTS This model can be converted for use with an LP cylinder which can be purchased locally from an LP supplier or other retail outlet The cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B339 Cylinder Spheres and Tubes for the Transportation of Dangerous Goods To minimize the potential for fire or an explosion the following precautions should be observed when using filling or storing an LP cylinder Never use a dented or rusty LP tank If there is any question as to the soundness of the tank have it checked by your LP supplier Never use a tank with a damaged or defective shut off valve Always close the tank shut off valve after use Do not overfill the LP cylinder Never fill the LP cylinder beyond eighty percent 80 of its capacity Overfilling will cause the pressure relief valve on the cylinder to vent excess gas vapor This vapor is combustible and can ignite causing a fire When transporting an LP cylinder insure it is in an upright position and away from any sources of high heat Do not store additional LP cylinders inside the enclosure for the unit Cylinders must be stored outdoors in a well ventilated
2. a qualified technician If you smell gas when the unit is in use immediately shut off all controls Let the gas dissipate for at least five minutes Relight the burner s and verify that they are operating properly If the burner s fail to relight or are not operating properly shut of the gas to the unit and have the unit checked by a qualified service technician This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Be aware that spiders and insects can nest in the burners of this cooktop This can obstruct the proper flow of gas into the burner and cause improper operation fire hazard and potential damage to the unit Inspect the burners periodically or immediately if any of the symptoms denoted in Section 7 exist Check Burner Air Adjustment Page 12 The burning of gas cooking fuel generates some by products that are on the list of substances which are known by the State of California to cause cancer or reproductive harm California law requires businesses to warn customers of Warning California Proposition 65 B potential exposure to such substances To minimize exposure to these substances always operate this unit according to the instructions contained in this booklet and provide good ventilation when cooking with gas
3. ext rieur seulement Si l appareil est entrepos l int rieur enlever les bouteilles et les laisser a l ext rieur SECTION 2 GAS REQUIREMENTS NATURAL GAS REQUIREMENTS Inlet Connection 1 2 NPT Supply Pressure 6 to 14 W C Manifold Pressure 5 W C PROPANE GAS REQUIREMENTS Inlet Connection 1 2 NPT Supply Pressure 1 to 14 W C Manifold Pressure 10 W C GAS CONSUMPTION The total gas consumption of the Thermador Outdoor Cooktop with all burners on HI is 30 000 BTU HR A IMPORTANT A manual gas shut off valve must be installed external to the appliance ina location accessible with the unit installed in the enclosure Make sure the valve is turned off prior to connecting the appliance A IMPORTANT Un robinet manuel d isolement doit tre install l ext rieur de l appareil dans un emplacement accessible avec l unit install e dans la module Assurez vous que le robinet est ferm avant de brancher l appareil A CAUTION The appliance must be isolated from the gas supply system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa When checking the manifold gas pressure the inlet pressure to the appliance regulator should be at least 7 0 W C for natural gas and 1 0 W C for propane Do notattemptany adjustment ofthe pressure regulator A ATTENTION
4. E Exterior Finish Cover The quality of this material resists most stains and pitting providing Stainless Steel the surface is kept clean and protected with a stainless steel polish Nonabrasive Cleaners detergent and water Fantastik 4099 vinegar Mild abrasive Cleaners liquid Kleen King Stainless Steel Polish Stainless Steel Magic Grates When removing the grates care should be taken in lifting them Be Porcelain Enamel sure to place the grate on a protected surface on Cast Iron NOTE Grates will develop bilsters and chips in the porcelain with use due to the extreme operating temperatures Hot sudsy water and mild abrasive cleaners Bon ami Soft Scrub For stubborn stains a soap filled steel wool pad Wash rinse and dry The occasional use of mild abrasive cleaners or steel wool soap filled pad is okay Abrasive cleaners used vlgorously or too often can eventually harm the enamel Apply with a damp sponge rinse thoroughly and dry Burner Ports and Caps Make certain that burners are turned OFF before cleaning Aluminum Porcelain Ports Clear ports of any soil with a Wire straightened paper clip or needle Wash in hot sudsy water Rinse and dry Caps Wash in hot sudsy water Rinse and dry For hard to remove soil use powdered cleaners such as Ajax Bon ami Comet Control Knobs Bezels Hot sudsy water Plastic Chrome Pullknobs straightforward Wash do not soak Rinse dry and replace Mak
5. HOOK UP Remove the burn FIGURE 5 er orifices Use a 7mm hex socket on a 3 ratchet Foam Tape extension and apply a piece of foam tape to the socket to hold the orifice in the Lag Orifice Size Regulator 5 0 W C k hil eS MM Hex Socket while re 4 1 2 NPT 3 A f moving P as Nipple See Figure 5 eX 7 Adapter 1 27 NM Replace with the to 3 8 flare fittin Threading compound e FIGURE 6 LP orifices supplied y be resistant to Counter Clockwise number 115 meine to remove Tighten until snug See Figure 6 Installer supplied Gas Hose shut off Valve must not supplied be easily accessible Reassemble the burner bases and CONVERSION FROM NATURAL venturis Reinstall GAS TO LP LIQUID PROPANE burner caps and Clockwise to tighten grate Model SB2B is manufactured at the factory for use with natural gas and as such requires conversion for use with an LP gas supply The conversion should be done by a qualified technician or your gas supplier All orifices required for conversion are provided with the unit Steps continue on next page SECTION 5 UNPACKING AND PLACING THE UNIT By pass Jet Location FIGURE 8 The bypass jet must be turned clockwise with a small flat bladed screwdriver until fully seated to set Pin proper low flow rate See Figures 7 and 8 above Position for Propane The cooktop is supplied with a pressure regulator that is
6. L appareil doit tre isol du circuit d alimentation de gaz en fermant son rob lnet manuel d isolement individuel pendant toutes essais sous pression du circuit de tuyauterie d alimentation de gaz aux pressions d essai gales a ou moins de 3 5kPa 1 2 psig En controlant la pression de gaz du tubulure la pression de prise au r gulateur de l appareil devrait tre au moins l 2mm HG pour gaz naturel et 20 5mm HG pour gaz de propane N essayez aucun r glage du r gulateur de pression A CAUTION When connecting to propane gas supply make certain that the propane gas tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the appliance The pressure of the gas at the appliance regulator must not exceed 4 water column BD ec En se reliant a approvisionnement de gaz de propane assurez vous que le r servoir de gaz de propane est quip de son Propre r gulateur haute pression en peus du r gulateur de Pression fourni avec l appareil La pression du gaz au r gulateur de l appareil ne doit pas ex ceder 26 1 mm HG For Massachusetts Installations Shut off valve must be a T handle gas cock Flexible gas connector must not be longer than 36 inches Not approved for installation in a bedroom or a bathroom unless unit is direct vent SECTION 3 SITE PREPARATION BUILT IN INSTALLATIONS Determine a suitable locat
7. Thermador Installation Instructions and Owner s Manual for Thermador Outdoor Cooktop Model SB2B Installer Please leave these instructions with the unit for the owner Owner Please retain these instructions for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Si l information dans ce manuel n est pas suivie exactement A une incendie ou une explosion peut r sulter entrainant des d gats mat riels des blessures ou la mort A Special Message to Our Customers Thank you for selecting the Thermador Outdoor Cooktop We recom mend that you take time to read this entire booklet before using your new appliance for the first time This booklet contains important safety information installation instructions operation and care suggestions Keep it in a handy place as it has the answers to many of your questions that may occur when you start to cook Let us know if we can help you When you write please include the model and serial numbers of your cooktop Sincerely Thermador Test Kitchen Consumer Scientists Contents SECTION I Safety Information SECTION 2 Gas Requirements Natural Gas Requirements Propane Gas Requirements Gas Consumption SECTION 3 Site Preparation Built In Installations Cabinet Preparation SECTION 4 Electrical Cautions Electrical Requirements Gro
8. area out of direct sunlight and or sources of high heat and out of the reach of children LP cylinder supply system must be arranged for vapor withdrawal LP cylinder used must include a collar to protect the cylinder valve The LP cylinder must be disconnected and removed from the appliance if the appliance is to be stored indoors Always check for leaks after every cylinder change See Section 6 of Installation Instructions FOR YOUR SAFETY The gas supply must be turned off at the LP gas supply cylinder when this outdoor cooking gas appliance is not in use The LP gas supply cylinder must be dis connected when this outdoor cooking gas appliance is not in use AVERTISSEMENT L alimentation du gaz doit tre fenn e a la bouteille de gaz de p trole liqu fi lorsque cet appareil de cuisson ext rieur n est pas utilis La bouteille d alimentation en gaz de p trole liqu fi doit tre d branch e lorsque cet appareil de cuisson ext rieur n est pas utilis FORYOUR SAFETY An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance AVERTISSEMENT Une bouteille de propane qui n est pas raccord e en vue de son utilisation ne doit pas etre entrepos e dans le voisinage de cet appareil ou de tout autre appareil FORYOUR SAFETY For Outdoor Use Only If stored indoors detach and leave cylinder outdoors AVERTISSEMENT Pour utlilisation a la l
9. e certain the knobs are reinstalled In the proper location Do not force knobs onto wrong control SECTION 9 SERVICE Before Phoning for Service Troubleshooting Power Failure In the event of a power failure the Thermador Outdoor Cooktop may still be used by lighting the burners with a match If Burners Fail to Ignite If the burners fail to ignite verify that the unit is connected to a properly grounded duplex outlet If electricity is present look for spark to jump from the spark ignitor to the burner when the ignition switch is depressed and held Make sure that the spark ignitors and burners are clean and dry Verify that burner caps are in the correct position on the burner bases Service Information The data rating label shows the model and serial numberfor your cooktop Italso gives information regarding burner rating and installation requirements The data rating label is located on the underside of the unit For handy reference copy the information below from the data rating label Keep your invoice for warranty validation Model Number Serial Number Date of Purchase Dealer s Name Dealer s Phone Number Service Center s Name Service Center s Phone Number To Obtain Replacement Parts order from the dealer where the unit was purchased or dial the telephone number listed below HOW TO OBTAIN SERVICE For authorized service or parts information phone 800 735 4328 We
10. ectly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug AVERTISSEMENT Instruction pour la mise a la terre electrique Cet appareil est muni d une fiche a trots broches misealaterre afin de vous proteger des chocs et doit etre branche dire ement dans une prise de courant a trots broches adequatement mise a la tem Il ne faut pas couper ou enlever la broche de mise a la tem de cette fiche A CAUTION The Thermador Outdoor Cooktop uses an electronic ignition system that requires a 120 VAC 15A 60 Hz power supply A properly grounded duplex outlet must be provided adjacent to the lower left rear corner of the unit See Figure 2 below Figure 2 Cooktop Three Prong Plug and Receptacle SECTION 5 UNPACKING AND PLACING THE UNIT LOCATING YOUR The following steps are necessary to OUTDOOR COOKTOP convert for LP operation Unpackand removeall accessory items packing materials and product literature from the unit Attach the gas FIGURE 4 pressure regulator to the end of the manifold as shown in Figure 3 Note the direction of gas flow Connect one end of an approved outdoor gas supply hose to the regulator inlet Connect the opposite end of the hose to the installer supplied shut off valve Refer to Section 2 for gas requirements Remove the grate burner caps ven turis and burner bases See Figure 4 FIGURE 3 NATURAL GAS
11. instructions accompanying product or write Thermador indicating the model number Thermador reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian distributor or dealer Thermador 555 McFadden Avenue Huntington Beach CA 92649 For the most up to date critical installation dimensions by fax use your fax handset and call 702 833 3600 Use code 8030 had Thermador 5551 McFadden Avenue Huntington Beach CA 92649 800 735 4328 ECO 4028 08 04 638B BSH Home Appliances Corp Litho U S A 4 00
12. ion for the cooktop by taking into account exposure to wind and availability of gas and electrical supplies Insure that the gas supply line and electrical supply are located in close proximity to the unit The 8 foot long electrical cord attached to the cooktop exits from the bottom left rear corner of the rough in box Keep connections to the unit as short as possible and allow for installation and removal of the unit from the enclosure Allow adequate area around the unit for dissipation of smoke produced during cooking Figure Non Combustible Enclosure for SB2B Cooktop 2 X 4 X 18 WOOD SUPPORT CABINET PREPARATION The model SB2B is designed for easy installation into masonry enclosures For noncombustible applications the cooktop drops into the opening shown in Figure below A ledge is required to support the cooktop from the bottom The supporting ledges must be level and flat The counter top should also be level Itis recommended that ventilation holes are provided in the enclosure in the event of a gas leak The installer supplied gas shut off valve must be installed in an easily accessible location Combustible Construction Clearances Minimum horizontal clearance from sides and back of unit to adjacent vertical combustible construction ex tending above top of unit 12 from sides and 12 from back Degagement horizontal minimal a respecter entre les cotes et l ar
13. ition switch The burner will light within 4 10 seconds 3 Adjust control knob to the desired flame setting For Manual Ignition Check that the burner caps are in correct position shown on Page 13 Turn control knob to the LITE position Place the lighted match on the burner cap ports Adjust control knob to the desired flame setting BURNER AIR ADJUSTMENT All burners are adjusted for proper flame characteristics at time of assembly All burners should exhibitflames which are blue and stable with no yellow tipping lifting or excessive noise when operating on either natural or LP gases If any of the flame characteristics noted above are observed check the burner for dirt or residue in the ports spider webs etc and clean or repair as necessary SECTION 7 USING YOUR OUTDOOR COOKTOP GENERAL BURNER INFORMATION Porcelain Each burner is rated at 15 000 BTU on High Enamel Cap Choose a pan base to fit the flame size The BURNER CAP flame should never extend beyond the base of the pan Neverturn ona burner without removing the cover When not in use place the stainless steel cover over the grate USING THE BURNERS Remove the burner cover FIGURE 13 Burner Base Check that the burner caps are in the correct position Tab A on the cap fits notch B on the base Put grate in position Follow Lighting Instructions on Page 12 SECTION 8 CARE AND CLEANING PART and MATERIAL SUGGESTED CAR
14. packed with the unit The regulator is set for natural gas For use with propane it must be converted The regulator will be located on the left rear bottom of the unit Using a flat blade screwdriver remove the cap on the top of the regulator and turn the cap over so that the letters LP are exposed Make sure the spring in the regulator remains in position Reattach the cap to FIGURE 9 the regulator See Figure 9 right Steps continue on next page SECTION 5 UNPACKING AND PLACING THE UNIT 7 If the cooktop will be used with an LP cylinder follow these steps A The Model LPHose is available at your Thermador dealer This assembly can also be purchased locally providing it meets the following specifications Hose length to be 24 Regulator must be a high pressure high volume unit capable of supplying adequate gas flow based on the input rating of the unit refer to Gas Consumption in Section 2 The inlet connector on the LP regulator must be compatible with the LP cylinder valve The hose and regulator assembly must be AGA certified for use with LP gas in an outdoor application Install a 1 2 NPT coupling at the end of the manifold located at the left rear bottom of the cooktop Use a pipe sealant approved for use with LP gases on all threads Attach gas regulator hose assembly to the coupling as shown in Figure 10 right Connect the gas regulator assembly to the LP tank valve Turn on
15. riere de l appareil et une construction combustible verticale adjacent depassant la partie superieure de l appareil soit 12 305mm pounces des cotes et 2 305mm ponces de l arriere Below the cooking surface combustible construction can be placed directly adjacent to the unit Non combustible Construction Clearances Above the cooking surface a minimum of I2 clearance from the sides is required to allow adequate access to pans A minimum of 3 clearance from the rear is required to allow for large pan sizes Below the cooking surface non combustible construction can be placed directly adjacent to the unit In all installations do not locate this outdoor cooking gas appliance under unprotected combustible overhead construction Il est interdit d installer le present appareil au dessous des surfaces combustibles non protegees SECTION 4 ELECTRICAL REQUIREMENTS AND GROUNDING INSTRUCTIONS A CAUTION Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances In the absence of local codes or ordinances the supply should be installed in accordance with the National Electric Code ANSI NFPA No 70 current issue or Canadian Electric Code C22 1 Part WARNING Electrical Grounding Instructions This outdoor cooking gas appliance is equipped with a three prong grounding plug for your protection against shock haz ard and should be plugged dir
16. sent shut off the gas at the supply Tighten any leaking fittings turn on the gas and recheck Leak Test Points Figure 12 Leak Test Points Plumbed Gas Supply SECTION 6 TEST AND ADJUSTMENT INSTALLER CHECKLIST V INSTALLATION Placement of unit Specified clearances maintained to combustible or noncombustible surfaces as applicable The burner box area is free of any packing materials and that the burners are properly located and installed Burner caps properly positioned and seated on burner bases ELECTRICAL Properly grounded receptacle is present for unit GAS SUPPLY Appliance is connected to the proper type of gas supply Manual gas shut off valve is installed in an accessible location with unit installed in enclosure for built in installations Unit tested and free from gas leaks Gas supply pressure does not exceed 14 W C If the unit is to be used with propane gas verify that the LP gas supply has its own high pressure regulator WARNING Remove the stainless steel burner cover before attempting to light the appliance Failure to remove the cover could allow gas to accumulate which could cause an explosion IF YOU SMELL GAS DO NOT ATTEMPT TO LIGHT ANY BURNERS LIGHTING INSTRUCTION For Electronic Ignition Make sure that all knobs are turned to the OFF position 2 Turn the knob to LITE position and immediately press the ign
17. the gas supply but do not attempt to light any burner Check the unit for leaks per the instructions in Section 6 Type Regulator Coupling 1 2 NPT fitting threading compound on these threads must be resistant to LP gas L P Regulator hose assembly 10 W C Regulator Adapter Main Type 1 gt FIGURE 10 SECTION 6 TEST AND ADJUSTMENT GAS AND ELECTRICAL HOOK UP With the unit inside of the enclosure connect the gas supply hose to the manual shut off valve and open valve Check the connection points at the shut off valve for any leaks and repair prior to installation of the unit See Figures I and 12 Connect the power supply cord to the electrical supply outlet CHECKING FOR LEAKS All points of connection to the gas supply should be checked for leaks at time of installation or anytime you smell gas It is also advisable to recheck them periodically Follow the steps outlined below A Makeasoap solution of one part liquid detergent and one part water xS Check h Makesureall controlsare in the OFF position far siis of Regulator Turn on the gas supply to the unit Use a spray abbrasions Assembly bottle brush or rag to apply the solution to all cracks Oneal fittings and points of connection from the supply stub out up to and including the inlet to the manifold See Figures I I and 12 Bubbles will Figure Leak Test Points form where a leak exists LP Cylinder Gas Supply lfa leak is pre
18. the hose assembly check under the unit through access opening in the enclosure Keep the area around the appliance clear and free from combustible materials gasoline and other flammable vapors and liquids Do not place any items in front of the unit while in use This could obstruct the proper flow of air needed for proper combustion and ventilation Keep ventilation opening s ofthe LP cylinder enclosure free and clear of obstructions and debris Keep electrical supply cord and the fuel supply hose away from any heated surfaces Do not leave the cooktop unattended while cooking WARNINGS FOR SAFE GAS INSTALLATIONS A GENERAL SAFETY PRECAUTIONS Read this manual carefully before using the cooktop to reduce the risk of fire electric shock or injury to persons Insure proper installation Have the installer show you where the gas supply shutoff valve is located and how to shut off the gas to the cooktop Always adhere to the minimum clearances to combustible materials as specified in Section 3 Do not repair or replace any part of this appliance unless specifically recommended in this manual All other servicing should be referred to a qualified service technician If you smell gas when the unit is not in use have the unit checked for leaks as defined in Section 6 Finding a gas leak is not a do it yourself procedure as some leaks can only be found with the burner control in the ON position This must be done by
19. ue to other than normal home use Any service visits and labor costs during the limited warranty Travel fees and associated charges incurred when the product is installed in a location with limited or restricted access i e airplane flights ferry charges isolated geographic regions This warranty applies to appliances used in residential application it does not cover their use in commercial installations This warranty is for products purchased and retained in the 50 states of the U S A the District of Columbia and Canada Should the appliance be sold by the original purchaser during the warranty period the new owner continues to be protected until the expiration date of theoriginal purchaser s warranty period The warranty applies even if you should move THERMADOR DOES NOT ASSUME ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may notapply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state or province to province Specifications are for planning purposes only Refer to installation instructions and consult your countertop supplier prior to making counter opening Consult with a heating and ventilating engineer for your specific ventilation requirements For the most detailed information refer to installation
20. unding Instructions SECTION 5 Unpacking Moving and Placing the Unit Locating your Char Glo Barbecue Natural Gas Hook up Natural Gas to Liquid Propane Conversion Liquid Propane Hook up SECTION 6 Test and Adjustment Checking for Leaks Installer Checklist Lighting Instructions Burner Air Adjustment SECTION 7 Using Your Outdoor Cooktop SECTION 8 Care and Cleaning SECTION 9 Service SECTION 10 warranty SECTION I SAFETY INFORMATION FOR YOUR SAFETY If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues immediately call your gas supplier or your fire department FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance AVERTISSEMENT S il y a une odeur de gaz Coupez l admission de gaz de l appariel nteindre toute flamme nue Si l odeur peraiste appeler immediatement votre compagnie de gaz ou votre departement des incendies AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans le voisinage de l appareil ni de tout autre appareil Une bouteille de propane qui n est pas raccord e en vue de son utilisation ne doit pas etre entrepos e dans le voisinage de cet appareil ou de tout autre appareil Installation and service m
21. ust be performed by a qualified installer service agency or the gas supplier TESTED IN ACCORDANCE WITH ANSI Z21 58 1995 ANSI Z21 58a 1998 STANDARD FOR OUTDOOR COOKING GAS APPLIANCES AND CAN CGA 1 6 M95 CGA l 6a M98 STANDARD FOR OUTDOOR COOKING GAS APPLIANCES This unit is for outdoor use only in a well ventilated area Not to be used in a building garage or any other enclosed area Check your local building codes for the proper method of installation In the absence of local codes this unit should be installed in accordance with the National Fuel Gas Code No Z223 Current Issue and National Electrical Code ANSI NFPA No 70 Current Issue or the CAN CGA BI49 Natural Gas Installation Code or CAN CGA B1 49 2 Propane Installation Code and C22 Canadian Electrical Code Part SECTION I SAFETY PRACTICES TO AVOID PERSONAL INJURY A IMPORTANT INFORMATION This outdoor gas cooking appliance is not intended to be installed in or on recreational vehicles and or boats Always inspect the natural gas or LP gas hose assembly before each use of the appliance If there is evidence of excessive abrasion or wear or if the hose is cut it must be replaced prior to the appliance being put into operation Replacement hose assemblies can be purchased at barbecue supply stores or ordered through Thermador If purchased at a retail outlet the hose assembly must be identical to the one supplied with the unit To inspect
22. want you to remain a satisfied customer If a problem does come up that cannot be resolved to your satisfaction please let us know Write Thermador Customer Call Center 5551 McFadden Avenue Huntington Beach CA 92649 or phone 800 735 4328 Please provide us with the Model Number Serial Number and Date of Original Purchase Installation SECTION 10 WARRANTY Wheranly Full One Year Warranty Covers one year from the date of installation or date of occupancy for a new previously unoccupied dwelling Save your dated receipt or other evidence of the installation occupancy date Thermador Will Pay For All repair labor and replacement parts found to be defective due to materials and workmanship Service must be provided by a Factory Authorized Service Agency during normal working hours For a Service Agency nearest you please call 800 735 4328 Thermador Will Not Pay For l Service by an unauthorized agency Damage or repairs due to service by an unauthorized agency or the use of unauthorized parts Service visits to Teach you how to use the appliance Correct the installation You are responsible for providing electrical wiring and other connecting facilities Reset circuit breakers or replace home fuses Damage caused from accident alteration misuse abuse improper installation or installation not in accordance with local electrical codes or plumbing codes or improper storage of the appliance Repairs d