Home
Thermador PG304 User's Manual
Contents
1. 16 Step 9 Test and Adjustment 17 Installer Checklist 18 Important Installation Information INTRODUCTION The Thermador Professional Ranges are free standing units available in a number of configurations Model PG304 is equipped with four sealed gas surface burners and a 30 inch gas convection self cleaning oven with broil capability Models PG364GE PG364GL and PG366 feature a gas cooking surface with four sealed gas surface burners with either an electric griddle or gas grill or six sealed gas surface burners plus a 36 inch gas convection self cleaning oven with broil capability Mod els PG484GGE PG486GE and PG486GL feature a gas cooking surface with four sealed burners electric griddle and gas grill six sealed burners and an electric griddle or six sealed burners and a gas grill PG48 Ranges provide a large gas self cleaning oven the same as used in the PG36 Ranges and a small gas oven with broil capability GAS type verification Verify the type of gas supplied to the location Ensure that the appliance is connected to the type of gas for which it is certified All ranges are certified for use with natural gas or propane LP gas Make certain the range matches the gas type available Important Abackguard must be utilized when there is less than a12 horizontal clearancebetweencombustible mate rials and the back edge of the ran
2. conditions may require readajustments Flame evaluation is performed with burner s control knob at highest setting Burner flames should be blue and stable with no yellow tips exces sive noise or lifting of the flame from the burner If any of these conditions exist check that the air shutter grill only or burner ports are not blocked or clogged Re move any blockages that exist If the flame is too yellow indicating insufficient air increase the shutter opening to increase air inlet grill only The sealed top burner flames should be approximately 1 to 11 2 high The grill flames should be as shown in Fig 17 NOTE No air shutter or low flame adjustment is necessary or pos sible with the sealed top burners FIG 17 Proper Flame Approx Top Bumers To Clean and protect Exterior Surfaces The stainless steel surfaces may be cleaned by wiping with a damp soapy cloth rinsing with clear water and drying with a soft cloth to avoid water marks Any mild glass cleaner will remove fingerprints and smears For discolorations or deposits that persist refer to the Care and Use Manual To polish and protect the stainless steel use a cleaner polish such as Stainless Steel Magic 17 Grill to 1 Y DO NOT allow deposits to remain for long periods of time DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust DO NOT allow salt solutio
3. HNI54YS 2 Hood Placement e For best smoke elimination the lower edge of the hood should be installed aminimum of 30 to a maximum of 36 above the range cooking sur face See Fig 1 e Ifthe hood contains any com bustible materials i e a wood covering it must be a mini mum of 36 above the cooking surface 3 Consider Make Up Air Dueto the high volume of ven tilation air a source of outside replacement air is recom mended This is particularly important for tightly sealed and insulated homes e A qualified heating and venti lating contractor should be consulted ISLAND INSTALLATION BLOWER VTR1000Q VTR1400Q VTR1000Q VTR1400Q VTR1400Q PHI60ZS Notes For wall installations where adequate space is available the installer or user may elect to use a hood that is wider than the range cooking surface This may be particularly beneficial for those cases such as a long duct run or heavy usage of the grill in which improved capturing of the cooking exhaust is desired Thermador offers a choice of remote VTR1000Q or VTR1400Q or in hood VTN1000Q blowers for use in wall installations Step 2 Cabinet Preparation 1 The range is a free standing unit If the unit is to be placed adjacent to cabinets the clearances shown in Fig 1 are required The same clear ances apply to island installations except for the overhead cabinets which must have a space wide enough to accept the flar
4. USA and in accordance with CAN 1 1 M81 Domestic Gas Ranges Canadian It is strongly recommended that this appliance be in stalled in conjunction with a suitable overhead vent hood See Step 1 for Ventilation Requirements Due to the high heat capability of this unit particular attention should be paid to the hood and duct work installation to assure it meets local building codes A CAUTION To eliminate risk of burns or fire caused by reaching over heated surface units cabinet storage located above the surface units should be avoided Check local building codes for the proper method of appliance installation Local codes vary Installation electrical connections and grounding must comply with all applicable codes In the absence of local codes the appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223 1 FNPA 54 current issue and National Electrical Code ANSI NFPA 70 current issue In Canada installation must be in accor dance with the CAN 1 B149 1 and 2 Installation Codes for Gas Burning Appliances and or local codes This appliance is equipped with an intermittent inter rupted ignition device that cycles the two far left surface burners on and off when in the ExtraLow setting Step 1 It is strongly recommended that a suitable exhaust hood be installed above the range Downdraft ventilation should not be used The table below indicates the Thermador hoods by model number
5. gagements requis sont indiqu s la Figure 1 Les m mes d gagements s appliquent aux installations en lot except pour les armoires suspendues qui doivent laisser un espace suffisamment grand pour poser la hotte d lot vas e comme le montre la Figure 1 2 Les cuisini res de 91 4 cm 36 peuvent tre encastr es entre les armoires au del du bord de la partie frontale du four voir Figures 2A et 2B Les cuisini res de 76 2 cm 30 et de 121 9 cm 48 ne sont pas homologu es pour tre install es ras des armoires 44 MISEENGARDE Dans ce type d installation pour les cuisini res de 91 4 cm 36 la porte et l armoire peuvent comporter un risque de pincement 3 Les arriv es d lectricit et de gaz doivent se trouver dans les zones indiqu es a la Figure 3A REMARQUE La profondeur maximum des armoires en hauteur install es d un c t ou de l autre de la hotte est de 33 cm 13 Un d gagement minimum de 91 4cm 36 est n cessaire entre le dessus de la cuisini re et le dessous d une armoire non prot g e Si le dessous de l armoire en bois ou en m tal est prot g par un mat riau ignifuge d au moins 6 35 mm 1 4 rev tu d une feuille d acier no 28 MSG d au moins la m me paisseur de 0 38 mm 0 015 d acier inoxydable de 0 6 mm 0 024 d aluminium ou de 0 5 mm 0 02 de cuivre la distance minimum est de 76 2 cm 30 Les mat riaux ignifuges portent la marque UNDERWRITERS LAB
6. 91 4 cm 36 combustible en etlesmat riaux 18 ou 121 9 cm 48 Le a combustibles Table de cuisson Zone d arriv e d lectricit et de gaz voir Fig 3A Les dimensions etla position de cettezonevarienselonle mod le N Hauteur min de la cuisini re avec pieds l vateurs enti rement r traci s 91 1 cm 35 7 8 A Telque d fini dans le Code national du gaz combustible ANSIZ223 1 Hauteur max de la cuisini re derni re dition La hauteurdela cuisini re estr glable Le dessus dela avec pieds l vateurs enti rement cuisini re doit tre au m me niveau ou plus lev que le plan de travail d ploy s 93 3 cm 36 3 4 25 Chapitre 2 Pr paration de l e FIG 2A Vue lat rale P mie tage re p rieu __ Mat riaux combustibles A 32 5 8 Min 91 4 cm 36 des combustibles A Plaque de 29 112 mplacement Conversion des mesures 9 5 mm 3 8 9 8 cm 3 7 8 30 4 cm 12 32 7 cm 12 7 8 p tection basse Partie frontale 9 5 mm 3 8 Mur Plaque d habillage A Tel que d fini dans le Code national du gaz combustible ANSI Z223 1 version courante 55 9 cm 22 64 7 cm 25 1 2 66 9 cm 26 3 8 72 1 cm 28 3 8 74 9 cm 29 1 2 82 9 cm 32 5 8 120 3 cm 47 3 8 FIG 2B Vue lat rale Dist nce min de 91 4 cm 36 avecles mat riaux combustibles Enjoliveur pou
7. Exigences pour l alimentation de gaz et PAC CORSICA ICO CO nn za 33 Chapitre 6 Exigences pour l alimentation lectrique le branchement et la mise la terre oooooonnnnccicccccnnnnnnn 34 Chapitre 7 Installation de la plaque de protection 35 Chapitre 8 Installation de la porte 36 Chapitre 9 Test et r glage ococoononncccccinnnccncnoccccnnnnos 37 Liste de v rification de l installateur o o 38 21 Informations importantes INTRODUCTION Lescuisini res ThermadorProfessional sontdesappareils monoblocs disponibles enplusieurs configurations Lemod lePG304est quip d unetabledecuissondequatrebr leurs gazherm tiquementencastr setd unfour gaz convectionautonettoyant de76 2 cm 30 avec l mentdegrillage Latabledecuissondesmod les PG364GE PG364GL et PG366 comporte quatre br leurs a gaz herm tiquementencastr savecsoituneplaquedecuisson soitungrilou encoresixbrileursagazherm tiquementencastr splusunfouragaza convectionautonettoyantde91 4cm 36 avec l mentdegrillage La tabledecuissondesmod lesPG484GGE PG486GEetPG486GL est quip edequatrebrilleursagazherm tiquementencastr s d uneplaque decuissonetd ungril desixbr leursherm tiquementencastr setd une plaquedecuissonoudesixbr leursetd ungril Lescuisini res PG48sont quip s d un grand four agaz autonettoyant le m me que celuides cuisini res PG36 etd unpetitfouragazavec l mentd
8. between the gas supply and the appliance manifold pipe which exits the upper rear of the appliance The appli ance manifold pipe connection is 3 4 NPT See Photo A Use caution to avoid crimping the 3 4 flex line when making bends The gas supply connections should be made by a competent technician and in accordance with local codes or ordinances In the absence of a local code the installation must conform to the National Fuel Gas Code ANSI Z223 1 NFPA54 current issue Always use pipe dope or Teflon tape on the pipe threads and be careful not to apply excessive pressure when tightening the fittings Leak testing of the appliance shall be in accor dance with the following instructions e Turn on gas and check supply line connections for leaks using a soap and water solution e Bubbles forming indicate a gas leak Repair all leaks immediately after finding them Do not use a flame of any kind to check for gas leaks Photo A _ Channel for gas line Use 3 4 flex line to connect between the gas supply and the appliance manifold pipe which exits the upper left rear of the appliance Step 6 Electrical Requirements Connection amp Grounding e Prior to servicing appliance always disconnect appliance electrical supply cord from wall recep tacle Chart B Electrical Supply Circuit Requirements MODEL NUMBER VOLTAGE CIRCUIT RATING FREQUENCY PHASE PG304 PG366 PG364GL PG364GE PG4
9. installer une hotte plus large que la table de cuisson pour am liorer les performances de ventilation e Pour les installations en lot la largeur de la hotte devrait d passer d au moins 15 2 cm 6 des deux c t s de la table de cuisson de la cuisini re LARGEUR DE LA CUISINI RE CUISINI RE DE 76 2 CM 30po IMPORTANT Les hottes de ventilation et les ventilateurs sont con us pour une seule conduite murale Certaines r glementations municipales du b timent exigent toutefois une double conduite Consultez les normes applicables et ou la municipalit avant de d buter les travaux pour vous assurer que l installation des conduites r pond aux exigences locales e La vitesse du ventilateur de la hotte doit tre r glable afin de r duire le bruit et la perte d air chaud ou d air climatis lorsque la vitesse de ventilation maximale n est pas n cessaire Normalement la vitesse de ventilation maximale n est requise que lorsque l on utilise le gril INSTALLATION MURALE HOTTE PH30ZS PH30HQS PHE30 36 VENTILATEUR VTR1000Q VTR1400Q ou VTN 1000Q PH36ZS 42ZS VTR1000Q VTR1400Q CUISINIERE DE 91 4 CM 36po PH48ZS PH48HQS PHE48 60 CUISINIERE DE 121 9 CM 48po PHE36 42 HNW36YS HNW42 YS ou VTN 1000Q VTR1000Q VTR1400Q VTR1000Q VTR1400Q VTR1000Q VTR1400Q ou VTN 1000Q HTNI42YS HNI42YS PHI48ZS HTNI48YS HNI48YS HTNI54YS HNI54YS 2 Emplacement de la hotte e Pour une m
10. plaques de protection Modele de cuisini re 22 9 cm 9 30 5 cm 12 55 9 cm 22 9 5 cm 3 3 4 Plaque basse standard Plaque basse Plaque haute tag re Enjoliveur pour ilot Inclus avec la cuisini re N D N D 35 Chapitre 8 Installation de la porte MISE EN GARDE La porte est lourde et doit tre manipul e par deux personnes Hold down bracket Door installation removal pin hole Hinge Locking Pin Retain for future Door height adjustment Hinge Hanger Photo B Ins rez le crochet charni re de la porte dans le passage de charni re du cadre frontal Support Pins Bas de la porte Vis de r glage de hauteur Photo D FIG 16 36 Chapitre 9 Tests et r glages Installez toutes les pi ces d tach es telles que les chapeaux et les grilles des br leurs susceptibles d avoir t enlev es Assurez vous que les chapeaux de br leurs reposent bien sur leurs rainures d alignement plac es dans les bases des br leurs Avant de tester le fonctionnement de l appareil assurez vous que l alimentation en gaz et l appareil lui m me ne pr sentent pas de fuites et que l alimentation lectrique est branch e Ouvrez le robinet manuel d arr t de gaz V rifiez le fonctionnement des br leurs herm tiquement encastr s et du gril en enfon ant et en tournant chacun des boutons dans le sens contraire des aiguilles d une montre sur la po
11. r ceptacle NEMA 5 20 tel qu indiqu ci dessus Il est possible que le code de la construction local exige une m thode diff rente de filtage 27 Chapitre 2 Pr paration de l emplacement Alimentation lectrique pour toutes les cuisini res au gaz L installation des cuisini res a gaz doit tre planifi e de sorte que la boite de d rivation pour la prise ou la connexion de la conduite laisse le maximum d espace l arri re de l appareil Ce point est particuli rement important si la bo te de d rivation murale se trouve juste derri re la boite de d rivation de l appareil une fois celui ci install Afin de minimiser les torsions lors du branchement de l appareil a la prise ou la bo te orientez en premier lieu la prise ou le connecteur de la conduite et faites glisser sur la position FIG 3B RACCORDEMENT AU MUR 5 7cm max 2 1 4 ao tm 5 7 cm 2 1 4 max I une fois branch Cordon d alimentation et prise Bo te de d rivation et conduite IMPORTANT Pour tous les mod les dot s d une plaque de cuisson PG364GE PG486GE et PG484GGE une alimentation d di e de 20 A est requise pour bien fonctionner 28 Chapitre 3 D ballage manutention et mise en place de la cuisini re MISEENGARDE Un quipement adapt manipul par du personnel exp riment doit tre utilis pour d placer la cuisini re afin de ne pas endommager l appareil ni le planche
12. to propane gas ensure that the propane gas supply tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the range See STEP 5 NEMA 5 20 RECEPTACLE Step 2 Cabinet Preparation ELECTRICAL SUPPLY ALL GAS RANGES Installation of All Gas ranges must be planned so that the rough in ofthe junction box for the receptacle or conduit connection will allow maximum clearance to the rear of the unit To minimize binding when the unit is connected to the receptacle or junction box orient the receptacle or conduit connector and slide back into position FIG 3B Wall Connection 2 1 4 E maximum 2 1 4 maximum et when plugged in Power Cord amp Receptacle Junction Box amp Conduit IMPORTANT For all gas range models with electric griddle PG364GE PG486GE and PG484GGE dedicated 20 Amp service is required for proper operation Step 3 Unpacking Moving and Placing the Range A Caution Proper equipment and ad equate manpower must be used in moving the range to avoid injury and to avoid damage to the unit or the floor The unit is heavy and should be handled accordingly The range has an approximate shipping weight as shown in Chart A Itis recommended that the grates griddle plate and frame burner caps front kick panel and oven racks be re moved to facilitate handling This will reduce the weight as shown in Ch
13. 1 mm 3 4 tuyau flexible diam tre minimum Pression d alimentation 27 4 mb a 34 9 mb 11 a 14 a la colonne d eau Pression du collecteur 24 9 mb 10 ala colonne d eau AVERTISSEMENT Le tuyau de gaz ne doit pas passer l int rieur du couvercle arri re de la cuisini re Acheminez le tuyau de gaz parle canal pr vu ceteffet l arri re de l appareil 33 Un robinet manuel d arr t de gaz doit tre install l ext rieur de l appareil un endroit accessible par le devant dans le but de pouvoir couper l alimentation en gaz Le tuyau d arriv e de gaz ne doit pas g ner l arri re de l appareil Assurez vous que le robinet d arr t est ferm avant de raccorder l appareil La cuisini re est fournie avec un d tendeur non amovible qui a t mont l int rieur de mani re permanente Utilisez le tuyau flexible de 19 1 mm 3 4 pour raccorder l arriv e de gaz au tuyau du collecteur de l appareil ce dernier sort du c t sup rieur gauche l arri re de l appareil Le raccord du tube du collecteur est un filetage NPT 3 4 voir Photo A Prenez garde viter les pincements du tuyau flexible de 19 1 mm 3 4 dans les coudes Le branchement l arriv e de gaz doit tre effectu par un technicien comp tent conform ment la r glementation locale A d faut de r glementation locale l installation devra tre conforme la norme en vigueur am ricaine du gaz combusti
14. 4 lb 264 9 kg 584 lb 176 9 kg 390 lb 237 6 kg 524 lb 133 8 kg 295 lb 179 2 kg 395 lb FIG 5 Retrait des deux boulons arri re install s pour l exp dition Boulon afri te eii Ajustement de l angle de la plaque de cuisson V rifiez l ajustement du cadre de la plaque de cuisson en versant deux cuill res soupe d eau sur la surface de la plaque L eau devrait lentement glisser vers le bas graisse Si ce n est pas le cas corrigez l angle l aide des deux vis sous le cadre de la plaque de cuisson Commencez en tournant les vis d un quart de tour dans le sens contraire des aiguilles d une montre Tout ajustement ult rieur devrait tre fait l aide des quart de tour jusqu ce que l eau glisse dans le bac graisse 29 Chapitre 3 D ballage manutention et mise en place de la cuisini re En raison du poids de la cuisini re il convient d utiliser une plate forme roulettes souples pour la d placer Le poids doit tre uniform ment r parti sur la plate forme voir Figure 6 Transportez la cuisini re sur la plate forme pr s de son emplacement d finitif basculez la pour qu elle soit repose sur les pieds arri re puis retirez la plate forme PROT GEZ LE SOL SE TROUVANT SOUS LES PIEDS MORCEAUX DE BOIS TAPIS ETC AVANT DE METTRE LA CUISINI RE EN PLACE Installez le dispositif antibascule Chapitre 4 raccordez le gaz et l lectricit Chapitres 5 et 6 puis installez la plaque de
15. 86GL PG486GE PG484GGE 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 15 Amps 15 Amps 15 Amps 20 Amps 15 Amps 20 Amps 20 Amps Single Single Single Single Single Single Single For the PG All Gas Ranges a neutral supply wire must be provided from the power source breaker fuse panel because critical range components including the surface burner spark reignition modules require 120 VAC to operate safely and properly An improper 120 VAC power supply will cause malfunction damage to this appliance and possibly create a condition of shock hazard If the correct power supply circuit is not provided it is the responsibility and obligation of the in staller and user to have proper power supply connected This must be accomplished in accor dance with all applicable local codes and ordi nances by a qualified electrician In the absence of local codes and ordinances the power supply connection shall be in accordance with the Na tional Electrical Code Observe all governing codes and ordinances when grounding In the absence of these codes or ordinances observe National Electrical Code ANSI NFPA No 70 current issue Electric wiring diagrams and schematics have been placed in the toe kick area of the range for access by a qualified service technician IMPORTANT For all gas range models with electric griddle PG364GE PG486GE and PG484GGE dedicated 20 AMP service is required for prop
16. C re ceptacle is used for gas range models with electric griddle PG364GE PG486GE and PG484GGE with 20 AMP over current protection OPERATION a All internal packing materials removed Check below grates and grill pans and within oven s If used on propane gas verify that the propane gas supply is equipped with its own high pressure regulator in addition to the pressure regulator sup plied with the appliance Burner caps properly seated into burner bases Grill components properly seated not all models Refer to Use amp Care Manual for Grill details Bezels centered on burner knobs and knobs turn freely Each burner lights satisfacto rily both individually and with other burners operating Air Shutter adjustment for proper flame made for Grill See Step 9 and Fig 17 Griddle is tilted slightly forward and does not rock not all mod els Oven door hinges seated and hinge locks in proper position Door opens and closes prop erly Burner grates correctly posi tioned level and do not rock INSTRUCTIONS D INSTALLATION ene Pour toutes cuisini res a gaz Thermador Professional PG304 PG36 PG48 Thermadar Veuillez lire toutes les instructions avant de poursuivre Important Conservez ces instructions pour l inspecteur local de la compagnie de gaz Installateur Veuillez laisser ces instructions d installation avec l appareil pour le propri taire Propri taire Veuillez c
17. INSTALLATION INSTRUCTIONS T For Thermador Professional All Gas Ranges PG304 PG36 PG48 Thermadar Please Read Entire Instructions Before Proceeding IMPORTANT Save these instructions for the Local Gas Inspector s use INSTALLER Please leave these Installation Instructions with this unit for the owner OWNER Please retain these instructions for future reference WARNING Disconnect power before installing Before turning power ON be sure that all controls are in the OFF position IMPORTANT Local codes vary Installation gas connections and grounding must comply with all applicable codes Ah WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance E Do not touch any electrical switch E Do not use any phone in your building E immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions E f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas suppler For Massachusetts Installations 1 Installation must be performed by a qualified or licensed contractor plumber o
18. ORATORIES INC CLASSIFIED MINERAL AND FIBER BOARDS SURFACE BURNING CHARACTERISTICS panneaux de fibres et min raux class s caract ristiques d inflammation des surfaces suivie des taux de progression des flammes et des fum es Ces d signations sontindiqu es par FHC Flame Spread Smoke Developed Progression des flammes Production de fum e Les mat riaux ayant un taux O de progression de flammes sont ignifuges La r glementation municipale peut autoriser un taux de progression des flammes diff rent 24 4 Toute ouverture dans le mur qui se trouve derri re la cuisini re et dans le plancher sous la cuisini re doit tre referm e 5 Si la distance entre un mat riau combustible A et le bord arri re de la cuisini re au dessus de la table de cuisson est de moins de 30 5 cm 12 il est obligatoire d installer une plaque Thermador de protection arri re basse ou tag re sup rieure voir Figure 2A Si la distance du mat riau combustible A est sup rieure a 30 5 cm 12 il est possible d utiliser un enjoliveur Thermador pour lot voir Figure 2B Les Figures 2A et 2B indiquent l espace n cessaire pour chaque type de plaque de protection 6 L appareil ne doit jamais se trouver proximit de mat riaux combustibles d essence et d autres produits inflammables vapeurs ou liquides 7 Lair de combustion et de ventilation arrivant l appareil doit pouvoir circuler librement dans les cond
19. S CARPET PANELING ETC BEFORE PUSHING THE UNIT INTO POSITION The anti tip device must be installed STEP 4 gas and electrical connections should be made STEPS 5 and 6 and the backguard installed STEP 7 before the range is placed in its final position e For proper performance the professional range must be level It is very important for all products that have the griddle feature The range is leveled by adjusting the legs with a wrench e Replace the kick panel and install the oven door To install door see Page 16 Do not install the oven door until the range is in its final location It is important that the two 2 screws retaining the kick panel are secure to prevent accidental access to hot surfaces e Ensure that the burner caps are correctly seated on the burner bases of the range s cooktop Griddle Tilt Adjustment Check the griddle frame adjustment by pouring two tablespoons of water on the back of the griddle plate The water should slowly roll into the grease tray If not adjust the two screws under the back of the griddle frame Start with one half turn CCW of the screws Further adjustment should be made by one quarter turn until water slowly flows into the grease tray Step 4 Installing Anti Tip Device For all 30 and 36 ranges an anti tip device must be installed as per these instructions WARNING RANGE TIPPING HAZARD All ranges can tip and injury can result Topreventaccide
20. ackguard Installed Chart C Backguard Kit Model Numbers Range Model No 9 Std Low Back 12 Low Back 22 High Shelf 3 3 4 Island Trim Included with Range N A N A 15 Step 8 Door Installation CAUTION The dooris heavy and requires two people to handle it properly 1 Insert the door hinge into the hinge pocket in the front frame When the door is properly installed the bottom edge will be parallel to the front of the range and the hinge will click into position and support the weight of the door 2 Tip the door parallel to the floor to free the hinge locking pin 3 Carefully remove the pins The door is now free to close Install the hold down bracket Do not tighten screw Retain pins for future door removal 4 Adjust the door height so the latch lock lever and spacer gauge enters the slot in the door liner as the door is closing and the top of the door should be parallel to the bottom of the control panel Tighten down screw on hold down bracket 5 Oven door hinges seated and hold down bracket is located in proper locked position Now the door opens and closes properly 6 The toe kick panel should be mounted last to prevent damage by the door Photo B nsert the door hinge into the hinge pocket in the front frame Bottom of Door Height adjusting screw Photo D 16 Hold down bracket Door installation removal pin hole Hinge Locking Pin Re
21. ancher gauche Armoire droite gt 695 cm 2 1 2 Bord avant del distance habituelle des l armoire droite Y deuxc t s 32 Chapitre 5 Exigences de l alimentation du gaz et raccordement RACCORDEMENT V rifiez le type de gaz utilis l endroit o la cuisini re est install e Celles ci sont pr par es lusine avant exp dition pour tre aliment es par du gaz naturel ou du gaz propane La cuisini re doit correspondre au type de gaz utilis sur le site En cas d installation de l appareil haute altitude veuillez consulter la compagnie locale de gaz pour conna tre les dimensions correctes des orifices et autres r glages n cessaires permettant une bonne combustion du gaz l altitude indiqu e MISEENGARDE Si l appareil est aliment par du gaz propane le r servoir de gaz propane doit tre quip de son propre d tendeur en sus du d tendeur fourni avec la cuisini re La pression du gaz l entr e du d tendeur de la cuisini re ne doit pas d passer 34 9 mb 14 pouces la colonne d eau Exigences pour le gaz naturel Raccord d entr e 3 4 N P T externe 1 2 N P T interne Minimum 19 1 mm 3 4 tuyau flexible diam tre minimum Pression d alimentation 14 9 34 9 mb 6 a 14 a la colonne d eau Pression du collecteur 12 5 mb 5 a la colonne d eau Exigences pour le gaz propane Raccord d entr e 3 4 N P T externe 1 2 N P T interne Minimum 19
22. art A and allow the range to pass through 30 door ways See Figs 2A and 2B on Page 6 Do not remove the grill or griddle assemblies Remove the outer carton and packing material from the ship ping base The all gas ranges are held to the skid by four 4 bolts see Fig 4 and 5 After removing the bolts the range mustbe lifted and removed from the skid Remove angle mounting brack ets from range This requires the installer to remove two screws holding each bracket then remove bracket and rein stall screws Chart A 335 lbs 285 lbs Shipping Weight Weight without packing materials Without door s burner caps front kick panel and oven racks 215 lbs FIG 4 Removal of Two Front Shipping Bolts 30 Range 36 Range 48 Range 444 lbs 390 lbs 584 lbs 524 lbs 295 lbs 395 lbs FIG 5 Removal of Two Rear Shipping Bolts Left Rear Shipping Step 3 Unpacking Moving and Placing the Range e Due to the weight a dolly with soft wheels should be used to move this unit The weight must be supported uniformly across the bot FIG 6 Dolly Positioning Range tom See Fig 6 Must bo Uniformly e After transporting the professional range by Supported dolly close to its final location the range can on 2 rovided be tipped back and supported on the rear legs FSk on Bottom while the dolly is carefully removed THE FLOOR UNDER THE LEGS SHOULD BE PROTECTED WOOD STRIP
23. as install conform ment ces instructions En d pla ant la cuisini re pour nettoyage r paration ou autre assurez vous que le dispositif antibascule s est bien r enclench lorsque vous repoussez la cuisini re contre le mur Sinon dans l hypoth se d une utilisation anormale personne montant s asseyant ou s tendant sur une porte ouverte la cuisini re risque de basculer et de provoquer des blessures dues aux liquides chauds renvers s ou au poids de la cuisini re AVERTISSEMENT TOUTES LES CUISINI RES PEUVENT BASCULER DES PERSONNES PEUVENT TRE BLESS ES INSTALLEZ LES DISPOSITIFS ANTIBASCULE FOURNIS AVEC LA CUISINIERE e CONSULTEZ LES INSTRUCTIONS D INSTALLATION AVERTISSEMENT RISQUE D LECTROCUTION Soyez tr s prudent lorsque vous percez des trous dans le mur ou le plancher Des fils lectriques peuvent tre dissimul s dansles murs ou dans le plancher Identifiez les circuits lectriques pouvant se trouver l endroit o le dispositif antibascule estinstall puis d branchez les Le non respect de ces instructions risque d entra nerune lectrocution ou des blessures MISE EN GARDE Dommages caus s l quipement Contactez un installateur ou un entrepreneur qualifi pour d terminer la bonne m thode de per age des murs ou du plancher carrelage bois franc etc Ne faites pas glisser la cuisini re sur un plancher no
24. ble ANSI Z223 1 NFPA54 ou la norme canadienne Utilisez toujours de la p te joint ou du ruban Teflon sur les filets du tuyau et prenez garde ne pas serrer excessivement les raccords Les tests de fuite de l appareil seronttoujours r alis s conform ment aux instructions du fabricant Ouvrez le gaz et assurez vous qu il n y a pas de fuites l aide d une solution savonneuse N utilisez pas de flamme pour faire cette v rification Sach a Sea _ Canal pour le tuyau de gaz b Utilisez un tuyau flexible 19 1 mm 3 4 pour raccorder le tuyau du collecteur se trouvant dans la partie sup rieure gauche de l arri re de l appareil l arriv e de gaz Chapitre 6 Exigences pour l alimentation lectrique le branchement et la mise la terre e Avant d intervenir sur l appareil d branchez toujours le cordon d alimentation lectrique de la prise murale Tableau B Exigences pour les circuits d alimentation lectrique NUMERO DU MOD LE TENSION INTENSIT DU CIRCUIT FR QUENCE PHASE PG304 120 VAC PG366 120 VAC PG364GL 120 VAC PG364GE 120 VAC PG486GL 120 VAC PG486GE 120 VAC PG484GGE 120 VAC 15 Amps 15 Amps 15 Amps 20 Amps 15 Amps 20 Amps 20 Amps Monophas Monophas Monophas Monophas Monophas Monophas Monophas Pour tous les mod les PG de cuisini res gaz un fil d alimentation neutre doit tre install partir de la sour
25. ce d lectricit disjoncteur panneau de fusibles car certains composants de la cuisini re dont le module de production d tincelle pour les br leurs de la table de cuisson fonctionnent de mani re s re et ad quate sur le 120 VCA Une mauvaise alimentation lectrique entra nera des dysfonctionnements endommagera la cuisini re et peut provoquer un risque d lectrocution Si le circuit lectrique ne remplit pas les conditions n cessaires l installateur ou l utilisateur est responsable et tenu de faire faire une installation correcte et conforme la r glementation locale applicable par un lectricien qualifi A d faut de r glementation locale le branchement lectrique sera conforme au Code national de lectricit La mise la terre doit tre conforme l ensemble de lar glementation applicable d faut la norme am ricaine d lectricit ANSI NFPA N 70 en vigueur ou la norme canadienne sera appliqu e Les sch mas de c blage lectrique l intention du technicien qualifi ont t plac s dans la plaque d habillage de l appareil IMPORTANT Pour tous les mod les de cuisni res gaz dot s d une plaque de cuisson PG364GE PG486GE et PG484GGE une alimentation lectrique d di e de 20 A est requise pour un bon fonctionnement ATTENTION L appareil doit tre isol du syst me d arriv e de gaz en fermant le robinet manuel d arr t pendant tous les tests de pression d ali
26. ceptacle within the Electrical and Gas Supply Zone is acceptable NOTE A Manual Gas Shut Off Valve not shown must be easily accessible through an adjacent cabinet without moving the range 2 Maximum Protrusion from Wall for Gas Supply 3 4 Flex Line to Appliance 1 2 NPT 120 VAC Receptacle Shown or Junction Box Centerline of Electrical upply Zone Model A B C D PG30 8 12 10 6 1 2 5 1 4 PG36 10 1 2 15 10 1 2 6 1 2 5 1 4 PG48 16 1 2 16 15 1 2 6 1 2 5 1 4 NOTE Any opening in the wall behind the appliance and any opening in the floor under the appliance must be sealed IMPORTANT The cord supplied with gas ranges having electric griddle PG364GE PG486GE and PG484GGE requires a NEMA 5 20 receptacle shown here Local codes may require a different wiring method The All Gas ranges may be con nected to the power supply with a range supply cord supplied with range or by hard wiring to the power supply Itis the responsibil ity of the installer to provide the proper wiring components cord or conduit and wires and com plete the gas connection as dic tated by local codes and ordi nances and or the National Elec tric Code The units must be prop erly grounded Refer to Step 6 for details The range must be connected only to the type of gas for which it is certified If the range is to be connected
27. d air ou la flamme basse des br leurs herm tiquement encastr s de la table de cuisson Br leurs herm tiquement encastr s 254 mm 11 38 1 mm 1 1 2 Gril A 2 7 mm 11 25 4 mm 11 Y Nettoyage et protection des surfaces externes Les surfaces en acier inoxydable se nettoient en passant un chiffon mouill l eau savonneuse Rincez l eau claire puis s chez avec un chiffon sec pour viter les traces d eau Retirez les traces de doigts et les train es avec un produit vitres doux En cas de d coloration ou de tache persistante consultez le Manuel d utilisation et d entretien Pour faire briller et prot ger l acier inoxydable utilisez un produit nettoyant ou un poli comme Stainless Steel Magic 37 NE laissez PAS les taches s incruster N utilisez PAS de tampons ni de brosses m talliques De petits morceaux de m tal risquent d adh rer la surface et de la faire rouiller NE laissez PAS les solutions salines les d sinfectants l eau de Javel ou les produits de nettoyage en contact avec l acier inoxydable Ces produits contiennent en g n ral des produits chimiques susceptibles de l endommager Rincez les l eau puis s chez avec un chiffon sec Liste de v rification pour l installateur LISTE FINALE DE VERIFICATION A L appareil a t mis en place Q Les distances sp cifi es entre l appareil et les armoires adjacentes sont respect es Q Le nivellement de l ap
28. e hardwood etc Do not slide the range across an unpro tected floor Failure to follow these instructions may result in damage to wall or floor cover ings Tools Needed for Installation of Anti Tip Device Screwdriver Phillips Drill metal Hammer electric or hand Pencil or other marker Measuring tape or ruler 1 8 drill bit wood or metal wall or floor 3 16 carbide tipped masonry drill bit concrete or concrete block wall or floor 3 16 anchors drywall or concrete 2 each not required if mounting bracket is being attached to solid wood or 11 Step 4 Installing Anti Tip Device PG30 and PG36 All Gas Ranges Figures 8A and 8B Thermador Service Part No Qty Description 415078 4 Screw Phillips 10 x 1 1 2 487310 1 Anti Tip Bracket Floor Mounted IMPORTANT INSTALLATION INFORMATION e The anti tip bracket may be attached to a solid wood cio pan an ca inen tap E sue cabinet having a minimum wall thickness of 3 4 SnD O E For walls or floors composed of concrete or The thickness of the wall or floor may require use of concrete block dril 346 holes to a minimum ilabl local hardwar re o SPONS VATAN t ONE eal Ne depth of 1 3 4 then tap concrete anchors into e Inall cases at least two 2 of the bracket mounting each of the holes using a hammer screws must be fastened to solid wood or metal deal For walls or floors having ceramic tile covering Use appropriate anchors whe
29. e grillage V RIFICATION DU TYPE DE GAZ V rifiezletyped alimentationaugazfournidulieudinstallation L appareil doit tre raccord autype de gaz pour lequelilestcertifi Toutes les cuisini res sontcertifi es pourune utilisation avecdugaznatureloudu gazpropane Assurez vousquelacuisini recorrespondautypedegaz disponible IMPORTANT e On doit mettre en place une plaque de protection lorsque l espace horizontal entre les mat riaux com bustibles et le bord arri re de la cuisini re est de moins de 30 5 cm 12 On doit commander s par ement la plaque de protection basse Thermador et on doit l installer l arri re de la cuisini re Pour les installations en lot et autres installations avec un espace de plus de 30 5 cm 12 un enjoliveur en acier inoxydable est vendu en option afin de recouvrir les brides de montage de la plaque de protection e Assurez vous que l appareil convient au type de gaz fourni Consultez le Chapitre 5 de la page 33 avant de proc der l installation Alimentation en gaz Gaznaturel 14 9mbmin 6pouces lacolonned eau 20mb 8pouces nominal Gazpropane 27 4mb 11poucesalacolonned eau 34 9mb 14pouces max Alimentation lectrique Mod lesde 76 2cm 30 PG304 120VCA 60Hz monophas circuitde 15A Mod les de 91 4cm 36 PG366 120VCA 60Hz monophas circuitde 15A PG364GL 120 VCA 60Hz monophas circuitde 15A PG364GE avec plaque decuisson 120VCA 60 Hz monophas circui
30. ed island hood as indicated in Fig 1 2 The 36 ranges may be recessed into the cabi nets beyond the edge of the front face of the oven See Figures 2A and 2B The 30 and 48 ranges are not approved to be installed flush with the cabinets Caution In these installations the door and cabinet on 36 inch models can cause a pinching hazard 3 The gas and electrical supply should be within the zones shown in Fig 3A Note The maximum depth of over head cabinets installed on either side of the hood is 13 A 36 inch minimum clearance is required between the top of the range and the bottom of an unprotected cabinet A 30 inch minimum distance is necessary when the bottom of the wood or metal cabinet is protected by not less than 1 4 inch of a flame retar dant material covered with not less than No 28 MSG sheet steel 0 015 inch 0 4 mm thick stainless steel 0 024 inch 0 6 mm aluminum or 0 020 inch 0 5 mm thick copper Flame retardant materials bear the mark UNDERWRITERS LABORATORIES INC CLASSIFIED MINERAL AND FIBER BOARDS SURFACE BURNING CHARACTERISTICS Followed by the flame spread and smoke ratings These designations are shown as FHC Flame Spread Smoke Developed Materials with O flame spread ratings are flame retardant Local codes may allow other flame spread ratings 4 Any openings in the wall behind the range and in the floor under the range must be sealed When there is less tha
31. ee Figs 3 Min to 2A and 2B 36 Range width combustible Min to combustible l terial A or 48 side wall gt ma PE 30 36 or 48 material A from cooking both sides surface le Cooking Surface For Electrical and Gas Supply Zone see Figure 3A Zone size and position differ according to the model retracted 36 3 4 Max Range Height with Leveling Legs fully extended A as defined in the National Fuel Gas Code ANSI Z223 1 Latest Edition The range height is adjustable The level of the range top must be at the same level or above the countertop level Step 2 Cabinet Preparation FIG 2A Side View ai pelear I 32 5 8 eli l 29 112 i ame et A FIG 2B Side View Note For Island trim installations counter surface should have a cantilever edge meeting the back section of the island trim accessory 12 Min to i Combustibles A 36 Min del without Backguard Combustibles A or with Island Trim Island Trim Y il El Front Face Cantilever Countertop Note If an inner wall is used under the cantilever counter top there should be a 1 8 gap from the rear of the range to the inner wall Step 2 Cabinet Preparation GAS AND ELECTRIC SUPPLY ZONES FIG 3A Gas 4 Electrical Supply Zones for All Gas Ranges Typical placement shown Other placement of Electrical Supply and Re
32. eilleure limination des fum es le bord inf rieur de la hotte doit tre plac a une distance minimale de 76 2 cm 30 et maximale de 91 4 cm 36 au dessus de la table de cuisson voir Figure 1 e Si la hotte contient des mat riaux combustibles comme par exemple un placage en bois elle doit tre plac e au moins 91 4 cm 36 au dessus de la table de cuisson 3 Apport d air e Un important volume d air tant n cessaire pour la ventilation il est recommand de pr voir un apport d air de l ext rieur Cet aspect rev t une importance particuli re dans les logements bien isol s et tr s tanches e ll est conseill de consulter un entrepreneur en chauffage et en climatisation INSTALLATION EN LOT HOTTE HTNI42YS HNI42YS PHI48ZS VENTILATEUR VTR1000Q VTR1400Q VTR1000Q VTR1400Q VTR1400Q PHI60ZS Remarques Pour les installations murales si l espace est suffisant l installateur ou l utilisateur peut choisir une hotte plus large que la table de cuisson de la cuisini re Elle am liorera l vacuation des fum es si Pon utilise par exemple beaucoup le gril ou si la conduite est longue Pour les installations murales Thermador propose des mod les de ventilateurs distance VTR1000Q ou VTR1400Q ou incorpor s la hotte VTN1000Q 23 Chapitre 2 Pr paration de l emplacement 1 La cuisini re est un appareil monobloc Si elle est plac e au milieu des armoires les d
33. er operation CAUTION The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kPa The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig 3 5kPa When checking the manifold gas pressure the inlet pressure to the regulator should be at leas 6 0 14 9 mb W C for natural gas or 11 0 27 4 mb for propane Do not attempt any adjustment of the pressure regulator 14 Step 7 Backguard Installation The backguard must be attached before sliding the range into the final installed position A Low Back or FIG 14 High Shelf backguard must be installed when there is less than a 12 clearance between combustibles and the back of the range above the cooking surface See Fig 2A and 2B on Page 6 Front of Unit An Island Trim is available for covering the backguard N mounting flanges for island installations where there is a minimum of 12 of horizontal clearance between combustibles and the back of the range See Fig 2B on Page 6 e The backguard is inserted as shown in Fig 14 into the guide channels on the back of the range Secure the backguard with the 4 sheet metal screws pro vided B
34. ge The Thermador Low Back backguard must be ordered separately and installed atthe rear of the range Forisland installations and other installations with more than 12 clearance an optional stainless steel Island Trim is available to cover the backguard mounting flanges Verify that the appliance is correct for the type of gas being provided Refer to Step 5 on Page 13 before proceeding with the installation Gas Supply Natural Gas 6 inch water column 14 9 mb min 8 inch 20 mb nominal Propane Gas 11 inch water column 27 4 mb 14 inch 34 9 mb maximum Electric Power Supply 30 Model PG304 120 VAC 60 Hz 1Ph 15 Amp circuit 36 Models PG366 120 VAC 60 Hz 1Ph 15 Amp circuit PG364GL 120 VAC 60 Hz 1Ph 15 Amp circuit PG364GE with electric griddle 120 VAC 60 Hz 1Ph 20 Amp circuit CAUTION When connecting the unit to propane gas make certain the propane gas tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the range The maximum gas pressure to this appliance must not exceed 14 0 inches water column 34 9 mb from the propane gas tank to the pressure regulator CAUTION This unit is designed as a cooking appliance Based on safety considerations never use it for warming or heating a room This appliance has been tested in accordance with ANSI Z21 1 Standard for Household Cooking Appliances
35. il est conseill d viter d installer des armoires au dessus des tables de cuisson des appareils V rifiez lar glementation locale applicable pourconna trela bonne m thode d installation de l appareil Les r glementations locales varient L installation le branchement lectrique etla mise alaterre doiventrespectertouteslesr glementations applicables d faut de r glementation l appareil doit treinstall conform mentauxnormes am ricainesenvigueursurlegazcombustibleANSIZ223 1 NFPA54 etl lectricit ANSI NFPA70 Au Canada l installation doit tre conforme aux normes canadiennes CAN 1 B149 1 et 2duCodedu b timent pour l installation d appareils fonctionnantaugaz et ou le code de constructionlocal Cetappareil est quip d un syst me d allumage intermittent qui allume et teintles deux br leurs de gauchelorsqu ils sontr gl s sur ExtraLow Chapitre 1 Exigences pour la ventilation Il est fortement recommand d installer une hotte de ventilation appropri e au dessus de la cuisini re Une ventilation par contre tirage ne devrait pas tre utilis e Le tableau ci dessous num re par num ro de mod le les hottes Thermador que l on conseille d utiliser avec les cuisini res 1 Choix du mod le de hotte et de ventilateur e Pour les installations murales la largeur de la hotte doit tre au moins gale celle de la table de cuisson de la cuisini re Si l espace le permet il est souhaitable d
36. laquelle cet appareil est install 2 Le robinet d arr t de gaz doit tre pourvu d une poign e en T 3 La longueur maximum autoris e du tuyau de gaz est de 91 4 centim tres 36 AVERTISSEMENT Toutes les cuisini res peuvent basculer Des personnes peuvent tre bless es Installez un dispositif antibascule Consultez les instructions d installation AFIN DE DIMINUER LES RISQUES DE BASCULEMENT INSTALLEZ UN DISPOSITIF ANTIBASCULE ASSUREZ VOUS QUE LE DISPOSITIFANTIBASCULE EST BIEN EN PLAC CONFORM MENT AUX INSTRUCTIONS D INSTALLATION REMARQUE LE DISPOSITIF ANTIBASCULE EST OBLIGATOIRE POUR TOUTES LES CUISINI RES DE 76 2 CM 30 ET DE 91 4 CM 36 1 Remarque Cette cuisini re N EST PAS con ue pour les maisons mobiles ni pour les v hicules r cr atifs NE PAS installer cette gamme dehors o e 8 066 000 Mod le 304 Mod le PG364GL Mod le PG484GGE Mod le LB36R a plaque de Mod le LB48R a plaque de protection basse protection basse Table des matieres Pee CANES y PUC a aai 21 Information importante concernant l installation 22 Chapitre 1 Exigences pour la ventilation 23 Chapitre 2 Pr paration de l emplacement 24 28 Chapitre 3 D ballage manutention et mise en place de la cuisini re ssssssrsssrsssennanseeriass 29 30 Chapitre 4 Installation du dispositif antibascule 31 32 Chapitre 5
37. ll provide proper gas combustion at specified altitudes CAUTION When connecting unit to propane gas make certain the propane gas tank is equipped with its own high pressure regulator in addition to the pressure regulator supplied with the appliance The pressure of the gas supplied to the appli ance regulator must not exceed 14 34 9 mb water column Natural Gas Requirements Inlet Connection 3 4 N P T external 1 2 N P T internal Minimum 3 4 dia flex line Supply Pressure 6 to 14 water column 14 9 to 34 9 mb Manifold Pressure 5 water column 12 5 mb Propane Gas Requirements Inlet Connection 3 4 N P T external 1 2 N P T internal Minimum 3 4 dia flex line Supply Pressure 11 to 14 water column 27 4 mb to 34 9 mb Manifold Pressure 10 water column 24 9 mb Warning Gas line must not come in contact with any components inside back cover of range Run gas line in channel in back of range 13 HOOK UP A manual gas shut off valve must be installed external to the appliance in a location accessible from the front for the purpose of shutting off the gas supply The supply line must not interfere with the back of the unit Make sure the gas supply is turned off at the manual shut off valve before connecting the appliance The range is supplied with its own pressure regu lator that has been permanently mounted within the range body Use 3 4 flex line to connect
38. mballage ont t enlev s l int rieur V rifiez sous les grilles les lechefrites et dans le four 38 Q Si le cuisini re fonctionne au gaz propane assurez vous que l alimentation en propane est pourvue de son propre d tendeur en plus du d tendeur fourni avec l appareil Q Les chapeaux des br leurs reposent bien sur leurs bases Q Les composantes du gril sont bien en place certains modeles Voir le Manuel d utilisation et d entretien pour plus de d tails sur le gril Q Les cadrans des boutons sont bien centr s et les boutons tournent librement Q Chaque br leur s allume correctement seul ou avec d autres br leurs allum s O Le r glage de l obturateur d air pour obtenir la flamme d sir e pour le gril a t effectu Voir Chapitre 9 et Figure 17 Q La plaque de cuisson est l g rement inclin e vers l avant et ne bouge pas certains mod les Q Les crochets charni res de porte s du des four s sont bien en place et se verrouillent correctement La porte s ouvre et se ferme correctement Q Les grilles des br leurs sont bien plac es nivel es et ne bougent pas Notes Notes Notes Specifications are for planning purposes only Refer to installation instructions and consult your countertop supplier prior to making counter opening Consult with a heating and ventilating engineer for your specific ventilation requirements For the most detailed information refer to installation i
39. mentation en gaz lorsque ces pressions sont gales ou inf rieures 3 5 kPa 1 2 psig L appareil et son robinet individuel d arr t doivent tre d branch s du syst me d arriv e de gaz pendant tous les tests de pression du syst me si ces pressions d passent 3 5 kPa 1 2 psig Pour la v rification de la pression de gaz du collecteur la pression d entr e du d tendeur doit tre de 14 9 mb 6 au minimum pour le gaz naturel et de 7 4 mb 11 pour le propane 34 Chapitre 7 Installation de la plaque de protection La plaque de protection doit tre mise en place avant de placer la cuisini re son emplacement d finitif La plaque basse ou haute avec tag re est obligatoire si la distance au dessus de la table de cuisson entre les parois combustibles et l arri re de la cuisini re est inf rieure 30 5 cm 12 voir Figures 2A et 2B la page 26 Un enjoliveur pour installation en flot est disponible il recouvre les brides de montage de la plaque de protection la ou la distance horizontale entre les parois combustibles et l arri re de la cuisini re est d au moins 30 5 cm 12 voir Figure 2B page 26 La plaque de protection s ins re dans les glissi res l arri re de la cuisini re comme indiqu a la Figure 14 et est fix e par les quatre 4 vis a t le fournies FIG 14 Avant de l appareil Plaque de protection install e Tableau C R f rences pour les
40. n a 12 horizontal clear ance between combustible material A and the back edge of the range above the cooking sur face a Thermador Low Back or High Shelf backguard mustbe installed See Fig 2A When clearance to combustible material Ais over 12 a Thermador Island Trim may be used See Fig 2B Figures 2A and 2B indicate the space required for each type of backguard Always keep appliance area clear and free from combustible materials gasoline and other flam mable vapors and liquids Do not obstruct the flow of combustion and ven tilation air to the unit Step 2 Cabinet Preparation 44 CAUTION Do not install the Models PG304 and PG48 ranges such that the oven door is flush with the cabinet face A flush installation could result in damage to the cabinets due to exposure to high heat A As defined in the National Fuel Gas Code ANSI 2223 1 Latest Edition FIG 1 Cabinet Clearances For 30 Ranges 30 or 36 Wide Hood 42 or 48 for Island For 36 Ranges 36 or 42 Wide Hood 42 or 48 for Island For 48 Ranges 48 or 60 Wide Hood 48 54 or 60 for Island 30 Min to 36 Max bottom of overhead Hood Depth to cooking surface 36 if hood contains combustib materials A 35 7 8 Min Range Height with Leveling Legs fully Min Distance Between Overhead Cabinets of Combustible Material A 30 Range 30 36 Range 36 k 48 Range 48 13 Max ve Cabinet x CAUTION S
41. n fastening the mounting drill 3 16 holes through the tile only then drill into bracket to any material other than hardwood or metal the material behind the tile as indicated immedi e Prepare holes at fastener locations as identified below ately above For walls wall studs or floors composed of solid Ifthe range is moved to a new location the Anti Tip wood or metal drill 1 8 pilot holes Device must be removed and reinstalled For walls or floors composed of drywall sheet rock or other soft materials drill 3 16 holes to a The alternative floor mounted bracket shall be installed as follows a Place bracket on floor in position shown in Figure 8B b Secure to floor or wall stud c Later when the unitis installed the adjustable leg Po MOUNTING ANTI TIP BRACKET YOOO O O O a O will slide under the bracket FIG 8B Placement of Anti tip Bracket Top View gt 2 1 2 Le from edge of range Wall Line Cabinet Front Edge of Right Cabinet 12 Step 5 Gas Requirements and Hookup Verify the type of gas being used at the installation site As shipped from the factory units are configured for use with natural gas or propane LP gas Make certain the range matches the type of gas available at this location For installation of the appliance at high altitude please consult your local gas company for their recommen dation of the correct orifice sizes and any other necessary adjustments that wi
42. n prot g Le non respect de ces instructions comporte des risques de dommages des rev tements muraux ou de sol Outils n cessaires pour l installation du dispositif antibascule Tournevis Phillips e Perceuse lectrique ou manuelle Rubanamesurer ou r gle Foretde 3 2 mm 1 8 mur ou sol en bois ou m tal Foret b ton pointe carbure de 19 mm 3 4 mur ou sol en b ton ou blocs de b ton Ancrages de 4 8 mm 3 16 cloison en pr fabriqu ou b ton 2 inutile si le support de montage est fix sur du bois dur ou du m tal e Marteau e Crayon ou autre marqueur Chapitre 4 Installation du dispositif antibascule Toutes cuisinieres a gaz PG30 et PG36 Figures 8A et 8B R f rence pi ce d tach e Thermador Quantit Description 415078 4 Vis Phillips no 10 3 81 cm 1 1 2 487310 1 Patte antibascule montage ausol INFORMATIONS IMPORTANTES PROPOS DE L INSTALLATION La patte antibascule peut tre fix e une armoire en bois massif ayant une paroi d une paisseur minimum de 19 mm 3 4 Selon l paisseur du mur ou du plancher il peut tre n cessaire d utiliser des vis plus longues disponibles chez votre quincaillier Au moins deux 2 vis de montage de la patte doivent tre fix es sur le bois massif ou le m tal Utilisez des ancrages appropri s pour monter la patte antibascule sur un mat riau autre que le bois dur ou le m tal Pr parez les trous des emplacements de fixation tel qu indi
43. ns disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which could prove harmful Rinse with water after exposure and wipe dry with a clean cloth INSTALLER CHECKLIST FINAL CHECK LIST a a Placement of unit Specified clearances main tained to cabinet surfaces Unit Level front to back side to side Burner caps positioned prop erly on sealed burner bases All packaging material re moved Island trim or backguard at tached if horizontal clearance to combustible materials be hind cooking surface is less than 12 Check door adjustment and hold down brackets Kick panel in place and two 2 screws secure The griddle plate and frame is correctly positioned tilted slightly forward See page 10 for adjustment procedure GAS SUPPLY a Connection 3 4 N P T with a minimum 3 4 diameter flex line The appliance is connected only to the type of gas for which it is certified for use Manual gas shut off valve in stalled in an accessible loca tion without requiring removal of range Unit tested and free of gas leaks Gas supply pressure does not exceed 14 W C 34 9 mb ELECTRICAL a D Receptacle with correct over current protection is provided for service cord connection Proper ground connection Proper polarity at receptacle A NEMA 5 20 120 VA
44. nstructions accompanying product or write Thermador indicating model number We reserve the rightto change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the U S for use in Canada Check with your local Canadian distributor or dealer For the most up to date critical installation dimensions by fax use your fax handset and phone 775 833 3600 Use code 8030 Les sp cifications ne sont fournies qu a titre pr visionnel Consultez les instructions d installation et le fournisseur de votre plan de travail avant de le modifier Consultez un entrepreneur en chauffage et en climatisation pour vos conditions sp cifiques de ventilation Pour une information plus d taill e reportez vous aux instructions d installation jointes au produit ou bien crivez a Thermador en indiquant le num ro du mod le Nous nous r servons le droit de modifier les caract ristiques ou le design sans pr avis Certains mod les sont approuv s pour le Canada Thermador n est pas responsable des produits transport s des tats Unis pour tre utilis s au Canada Veuillez vous renseigner aupr s de votre distributeur ou d taillant canadien Pour obtenir les dimensions d installation tr s pr cises par t l copieur veuillez nous contacter par t l copieur et par t l phone au 775 833 8600 Utilisez le code n 8030 Thermador BSH Home A
45. ntaltipping of the range attach it to the floor wall or cabinet by installing the Anti Tip Device supplied A risk of tip over may exist if the appli ance is not installed in accordance with these instructions If the range is pulled away from the wall for cleaning service or any other reason ensure that the Anti Tip Device is prop erly reengaged when the range is pushed back against the wall In the event of abnormal usage such as a person stand ing sitting or leaning on an open door failure to take this precaution can result in tipping of the range Personal injury might result from spilled hot liquids or from the range itself WARNING ELECTRICAL SHOCK HAZARD Use extreme caution when drilling holes into the wall or floor There may be con cealed electrical wires located behind the wall or under the floor Identify the electrical circuits that could be affected by the installation of the Anti Tip Device then turn off power to these circuits Failure to follow these instructions may result in electrical shock or other per sonal injury WARNING e ALL RANGES CAN TIP e INJURY TO PER SONS COULD RE SULT e INSTALL ANTI TIP DEVICES PACKED WITH RANGE e SEE INSTALLATION INSTRUCTIONS CAUTION PROPERTY DAMAGE Contacta qualified installer or contractor to determine the proper method for drill ing holes through the wall or floor mate rial such as ceramic til
46. onserver ces instructions pour consultation ult rieure AVERTISSEMENT Coupez l lectricit avec d installer l appareil Avant de remettre l lectricit assurez vous que toutes les commandes sont sur la position OFF IMPORTANT Les r glementations locales varient L installation les raccordements au gaz et les mises la terre doivent tre conformes toutes les r glementations applicables AVERTISSEMENT L information fournie dans le pr sent manuel doit tre tr s rigoureusement respect e sous peine d incendie ou d explosion entra nant des dommages des blessures ou la mort Ne stockez pas et n utilisez pas d essence ou autres produits inflammables proximit des appareils SI VOUS D TECTEZ UNE ODEUR DE GAZ M Nallumez aucun appareil M Ne touchez pas aux interrupteurs lectriques M N utilisez pas les t l phones du b timent M Appelez imm diatement votre compagnie de gaz de chez un voisin Suivez les instructions de la compagnie E Sivous n arrivez pas contacter votre compagnie de gaz appelez les pompiers L installation etles r parations doivent tre r alis es par un installateur qualifi un centre de r paration agr ou la compagnie de gaz Pour les installations au Massachusetts 1 L installation doit tre r alis e par un entrepreneur qualifi ou agr un plombier ou un installateur de gaz qualifi ou autoris par l tat ou la r gion dans
47. ou au Code national de l lectricit On doit installer une mise alaterre ad quate pour les appareils Voir le Chapitre 6 pour plus de d tails Prise 120 VCA ilustr e ou boite de d rivation Zone d arriv e lectrique N REMARQUE On doit pouvoir acc der facilement l une des armoires adjacentes au robinet manuel d arr t de gaz non montr sur la Fig sans avoir d placer la cuisini re Saillie max de 5 1 cm 2 partir du mur de l arriv e des gaz La cuisini re ne doit tre raccord e qu au type de gaz pour lequel elle est certifi e Si elle est raccord e au gaz propane le r servoir de propane doit tre dot de son propre d tendeur en plus du d tendeur fourni avec la cuisini re voir Chapitre 5 Plancher AS Cu Modele A B C D PG30 20 3 cm 30 5 cm 25 4 cm 16 5 cm 13 3 cm PG36 26 4 cm 38 1 cm 26 4 cm 16 5 cm 13 3 cm PG48 41 9 cm 40 6 cm 39 4 cm 16 5 cm 13 3 cm REMARQUE Toute ouverture dans le mur se trouvant derri re l appareil ou dans le plancher sous l appareil doit tre bouch e Conversion des mesures 20 3cm 8 30 5cm 12 25 4cm 10 16 5 cm 6 1 2 13 3 cm 5 1 4 26 4 cm 10 1 2 38 1 cm 15 R CEPTACLE 39 4cm 15 1 2 NEMA5 20 40 6 cm 16 41 9 cm 16 1 2 IMPORTANT Les cordons fournis avec les cuisini res au gaz dot es d une plaque de cuisson PG364GE PG486GE et PG484GGE requi rent un
48. pareil d avant vers l arri re et d un c t l autre a t effectu Q Les chapeaux de br leurs ont bien plac s sur les bases A Tous les mat riaux d emballage ont t enlev s Q L enjoliveur pour lot ou la plaque de protection a t pos e si la distance horizontale avec mat riaux combustibles au dessus de la table de cuisson est inf rieure 30 5 cm 12 Q La porte et les plaques de maintien inf rieures ont t pos es Q La plaque d habillage a t fix e l aide de deux 2 vis ALIMENTATION EN GAZ Q Raccord filetage NPT de 3 4 3 4 avec tuyau flexible diam tre minimum 19 1 mm 3 4 A L appareil est bien raccord au type de gaz pour lequel il est certifi Q Le robinet manuel d arr t de gaz a t install un endroit accessible sans devoir d placer la cuisini re Q L appareil a t test et n a pas de fuites de gaz Q La pression d alimentation de gaz est inf rieure 34 9 mb 145 LECTRICIT Q La prise de courant a laquelle le cordon d alimentation est branch est bien prot g e contre les surtensions Q Une mise la terre ad quate a t install e Q Une polarit ad quate existe pour la prise le r ceptacle Q Une prise NEMA 5 20 de 120 VCA sert pour les mod les de cuisini res gaz avec plaque de cuisson PG364GE PG486GE et PG484GGE avec protection de surintensit de 20 A FONCTIONNEMENT Q Tous les mat riaux d e
49. ppliances Corp 5551 McFadden Avenue Huntington Beach CA USA 1 800 735 4328 ECO 5U008BG 9000051327 Rev A 2004 BSH Home Appliances Corp Litho USA 10 04
50. protection Chapitre 7 avant de placer d finitivement la cuisini re Pour garantir son bon fonctionnement la cuisini re professionnelle doit tre nivel e Ce point est important pour tous les produits quip s d une plaque chauffante La cuisini re se nivelle en r glant les pieds avec une cl Remettez la plaque d habillage en place puis installez la porte du four Pour installer la porte voir la page 36 Les deux 2 vis qui maintiennent la plaque d habillage doivent tre solidement fix es pour viter un contact accidentel avec les surfaces chaudes Assurez vous que les chapeaux des br leurs sont correctement assis sur les bases des br leurs delatable de cuisson dela cuisini re 30 FIG 6 Miseen place sur la plate forme roulettes Le poids de la cuisini re doit tre uniform ment r parti en s aidant des supports plac s sur le dessous de la cuisini re Chapitre 4 Installation du dispositif antibascule Pour toutes les cuisinieres de 76 2 cm 30 et de 91 4 cm 36 un dispositif antibascule doit tre install conform ment aux instructions suivantes AVERTISSEMENT DANGER DE BASCULEMENT Toutes les cuisini res peuvent basculer et blesser quelqu un Pour viterun basculementaccidentel elles doivent tre attach es au sol au mur ou une armoire au moyen de l installation du dispositif antibascule qui vous est fourni Unrisque de basculement demeure si l appareil n est p
51. qu ci dessous Pour les murs montants de mur ou sols en bois massif ou en m tal percez des trous de guidage de Pour les murs ou les sols de type pr fabriqu carton pl tre ou autres mat riaux mous percez des trous de 4 8 mm 3 16 une profondeur minimum de 4 45 cm 1 3 4 puis enfoncez les ancrages en plastique dans tous les trous l aide d un marteau Pour les murs ou les sols en b ton ou en blocs en b ton percez des trous de 4 8 mm 3 16 une profondeur minimum de 4 45 cm 1 3 4 puis enfoncez les ancrages b ton dans les trous l aide d un marteau Pour les murs ou les sols rev tus de carrelage percez des trous de 4 8 mm 3 16 de la profondeur du carrelage puis percez derri re le carrelage comme indiqu ci dessus Si la cuisini re doit tre ult rieurement plac e un nouvel endroit le dispositif antibascule sera enlev et r install 3 2 mm 1 8 MONTAGE DE LA PATTE ANTIBASCULE L option patte mont e au sol doit tre install e comme suit a Placez la patte sur l emplacement comme indiqu la Figure 8B b Fixez au plancher ou au montant de mur c Lorsque la cuisini re est install e le pied r glable se glissera sous la patte FIG 8A Montage de la patte antibascule Figure 8B Mise en place de la patte antibascule vue du gt 16 35 cme partir du bord de la haut 2 12 cuisini re Lien Ligne du mur Armoire Pl
52. r La cuisini re est lourde et repose sur des pieds r glables en acier Le poids approximatif de la cuisini re l exp dition est celui qui est indiqu au Tableau A Il est recommand d ter les grilles des br leurs la plaque de cuisson les chapeaux des br leurs la plaque d habillage et les grilles du four pour faciliter la manutention Le poids de l appareil s en trouvera diminu tel quindiqu au Tableau A et permettra la cuisini re de passer par une porte de 76 2 cm 30 Voir Figures 2A et 2B la Page 26 N tez pas le gril ni la plaque de cuisson Retirez l emballage externe et les mat riaux d emballage de la palette d exp dition Toutes les cuisini res gaz sont fix es sur une palette l aide de quatre 4 boulons voir Fig 4 et 5 Apr s avoir enlev les boulons soulevez la cuisini re et enlevez la de la palette Retirez les querres de la cuisini re Pour ce faire l installateur doit retirer les deux vis qui fixent chacune de ces querres Enlevez l querre puis remettez les vis Tableau A Poids l exp dition Poids sans mat riaux d emballage Poids hors porte s chapeaux de br leurs plaque d habillage et grilles de four FIG 4 Retrait des deux boulons avant install s pour l exp dition Cuisini re de 76 2 cm 30 152 kg 335 lb 129 3 kg 285 lb 97 5 kg 215 lb Cuisini re de 121 9 cm 48 Cuisini re de 91 4 cm 36 201 4 kg 44
53. r flot Distance min de 30 4 cm 12 entre les mat raux combustible sans arri re inifuge ou avec installation en il t Conversion des mesures 91 4 cm 36 30 5 cm 12 3 2 mm 1 8 Mat riaux F combustibles REMARQUE Pour installer l enjoliveur pour flot le plan de travail doit avoir un bord en porte faux venant se placer bord bord avec l arri re de l enjoliveur Aire de travail en porte a faux REMARQUE Si une paroi interne est utilis e sous l aire de travail en cantile ver la distance entre cette paroi et l arri re de la cuisini re doit tre de 3 2 mm 1 8 26 Chapitre 2 Pr paration de l emplacement GAZ ET ZONE ET LECTRIQUE D ARRIV E FIG 3A Gaz et zone lectrique d arriv e de toutes les cuisini res Installation typique illustr e Un autre type d installation du gaz et de l alimentation lectrique et du r ceptacle dans la zone d alimentation Tuyau flexible de 19 mm 3 4 vers l appareil Toutes les cuisini res gaz peuvent tre raccord es au secteur l aide du cordon d alimentation fourni avec la cuisini re ou bien directement cabl es L installateur doit fournir les l ments de c blage quiconviennent cordon ou conduite et c bles et du gaz et de l alimentation lectrique est acceptable Zone d arriv e du gaz Filetage NPT 12 7 mm 1 2 r aliser le raccordement au gaz conform ment la r glementation locale et
54. r gas fitter qualified or licensed by the state province or region where this appliance is being in stalled Shut off valve must be a T handle gas cock Flexible gas connector must not be longer than 36 inches WARNING M All Ranges can tip E Injury to Persons could result E Install Anti Tip Device H See Installation Instructions TO REDUCE THE RISK OF TIPPING OF THE APPLIANCE IT MUST BE SECURED BY A PROPERLY INSTALLED ANTI TIP DEVICE VERIFY THAT THE ANTI TIP DEVICEISENGAGED PER INSTALLATION INSTRUCTIONS NOTE ANTI TIP DEVICE IS REQUIRED ON ALL 30 AND 36 RANGES Note This Range is NOT designed for installa tionin manufactured mobile homes or for instal lation in Recreational Park Trailers Do Not install this range outdoors 066 9089 Model PG304 Model PG364GL Model PG484GGE Low Back Model LB36R Low Back Model LB48R Contents Introduction oooocccccccccncncncncnnnnnnnnnnnnnnninnnno 1 Important Installation Information 2 Step 1 Ventilation Requirements 3 Step 2 Cabinet Preparation 4 8 Step 3 Unpacking Moving and Placing the Range s 9 10 Step 4 Installing Anti Tip Device 11 12 Step 5 Gas Requirements and Hookup 13 Step 6 Electrical Requirements Connection and Grounding sesssseee 14 Step 7 Backguard Installation 15 Step 8 Door Installation
55. sition HI Les allumeurs des br leurs mettent des d clics jusqu a allumage de la flamme Les deux br leurs les plus gauche ont une fonctionnalit XLO grace a laquelle la flamme s allume et s teint lorsque le bouton est sur la position XLO MISE EN GARDE Les r glages des br leurs doivent tre r alis s par un technicien qualifi au moment de l installation Renforcezles pr cautions pour effectuer les r glages apr s l installation Des r glages incorrects ou noneffectu s peuventcauser des dommages collat raux ou annuler votre garantie II s agit d un fonctionnement normal Les flammes des br leurs doivent tre tout fait bleues pas de jaune l extr mit et stables ne pas produire un bruit excessif ni se d tacher du br leur Si l une de ces conditions appara t assurez vous que FIG 17 Flamme correcte Pobturateur d air gril seulement ou les orifices des br leurs ne sont pas bouch s ou obstru s Eliminez toute obstruction Si la flamme est trop jaune ce qui indique une insuffisance d air r glez l obturateur dans le sens contraire des aiguilles d une montre afin d augmenter l entr e d air gril seulement La hauteur des flammes des br leurs doit tre d environ 2 54 cm 1 3 81 cm 1 1 2 Les flammes de la plaque chauffante et du gril doivent pr senter l aspect indiqu a la Figure 17 REMARQUE II n est ni possible ni n cessaire de r gler l obturateur
56. t de 20 Mod les de 121 9 cm 48 PG486GL 120 VCA 60 Hz monophas circuit de 15 A PG486GE avec plaque de cuisson 120 VCA 60 Hz monophas circuit de 20 A PG484GGE avec plaque de cuisson 120 VCA 60 Hz monophas circuit de 20 A 22 a propos de l installation 44 MISEENGARDE Si l appareil est aliment au gaz propane assurez vous que le r servoir de propane est quip de son propre d tendeur en sus du d tendeur fourni avec la cuisini re La pression maximum d arriv e du gaz de cet appareil ne doit pas d passer les 34 9 millibars 14 pouces la colonne d eau entre le r servoir de propane et le d tendeur MISE EN GARDE Cet appareil est con u pour un usage culinaire Pour des raisons de s curit ne utilisez jamais pour chauffer une pi ce Cetappareila t test conform ment lanormeam ricaineANSIZ21 1 pour les appareils lectrom nagers de cuisson au gaz etalanorme canadienne CAN 1 1 M81 surlescuisini res gaz domestiques Onrecommandetortementd installerunehottede ventilaionadapt eau dessusdecetappareil voir Chapitre 1 Conditionsdeventilation Comme cetappareil peutd gager unefortechaleur ondoitporter une attention particuli re aux travauxd installationsdesconduits ete lahotte lesquels doivent tre conformes ala r glementation locale de construction mise EN Afin d liminer les risques de br lures ou d incendie provoqu s par la chaleur
57. tain for future door removal Door height adjustment Hinge Hanger Support Pins FIG 16 Step 9 Test and Adjustment Install any loose components such as burner caps and grates that may have been removed earlier Be certain that burner caps seat properly into the alignment slots in the burner bases Before testing operation of the appliance verify that the unit and the gas supply have been carefully checked for leaks and that the unit has been connected to the electrical power supply Turn the manual gas shut off valve to the open position Check operation of the sealed gas burn ers and grill by pushing and turning each knob counterclockwise to HI The burner igniters will click until the flame ignites The two far left sealed burners feature XLO causing the flame to cycle on and off when the knob is set to the XLO range This is normal operation CAUTION Burner adjustments must be made by a qualified technician at the time of installation Extreme care should be used when adjustments are made after installation Improper or lack of adjustments may cause harmful by products or void your warranty EACH GAS BURNER MUST BE EVALUATED FOR CORRECT FLAME PERFORMANCE IMME DIATELY AFTER INSTALLATION OF THIS APPLIANCE In PG Rangle models the air shutter for grill burner NOT top burners is preadjusted at the factory How ever environmental or installation
58. that are recommended for use with all ranges 1 Select Hood and Blower Models e Forwallinstallations the hood width must at a minimum equal the width of the range cooking surface Where space permits ahood larger in width than the cooking surface may be desirable for improved ven tilation performance e For island installations the hood width should at a mini mum overhang the range cooking surface by 6 on each side RANGE WIDTH 30 RANGE 36 RANGE 48 RANGE PH48ZS PH48HQS PHE48 60 Ventilation Requirements IMPORTANT Ventilation hoods and blowers are designed for use with single wall ducting However some local building codes or inspectors may require double wall ducting Con sult local building codes and or local agencies before starting to assure that hood and duct instal lation will meet local requirements e Hood blower speeds should be variable to reduce noise and loss of heated or air con ditioned household air when maximum ventilation is not required Normally the maxi mum blower speed is only re quired when using the grill WALL INSTALLATION HOOD PH30ZS PH30HQS PHE30 36 BLOWER VTR1000Q VTR1400Q OR VTN 1000Q PH36ZS 42ZS VTR1000Q VTR1400Q PHE36 42 HNW36YS HNW42 YS or VTN 1000Q VTR1000Q VTR1400Q VTR1000Q VTR1400Q VTR1000Q VTR1400Q or VTN 1000Q eJ0 HTNI42YS HNI42YS PHI48ZS HTNI42YS HNI42YS PHI48ZS HTNI48YS HNI48YS HTNI54YS
59. uites Chapitre 2 Pr paration de l emplacement MISEEN GARDE N installez pas les mod les de cuisini res PG304 et PG48 de telle sorte que la porte du four soit au ras de la partie frontale des armoires Une installation m me niveau risque d endommager les armoires d a leur exposition a la chaleur A Tel que d fini dans le Code Conversion des mesures nationaldugaz combustible 76 2 cm 30 versionen vigueur de lanorme 91 4 cm 36 ANSIZ223 1 106 7 cm 42 121 9 cm 48 137 2 cm 54 152 4 cm 60 FIG 1 D gagement des armoires Cuisini re de 76 2cm 30 Hotte de 76 2 cm 30 oude 91 4cm 36 106 7 cm 42 ou 121 9 cm 48 pour installation en lot it ais m 36 ou 42 Hotte uisini re de 91 4cm 36 106 7 om 42 ou 121 9 cm 48 pour installation en jlo Hotte de 121 9 cm 48 ou 152 4cm 60 121 9cm 48 137 2cm 54 ou 52 4 cm 60 pouninBtallatio en lot k Distance minimum entre les armoires suspendues compos es de mat riaux uisini re de 121 9cm 48 combustibles Cuisini res de 30 76 2 cm Profondeur N Cuisini res de 36 91 4 cm max de Distancemin de76 2 cm 30 et Cuisini res de 48 121 90m 33 em 13 MISE EN GARDE Voir distance max 91 4 cm 36 entre Fe 2h on Diane i ledessous de la hotte etla table or iT fa min de 91 4 cm 36 db elas M ra A Es lat rale 3 gt entre la table de cuisson de 45 8 cm eS nau 76 2 cm 30