Therma-Stor Products Group Santa-Fe Rx Free-Standing Dehumidification User's Manual

image

Contents

1. Keyholes lt ee ae za sa a Se teal Filter Senses qeWensge t MISS Catch Put this filter side in first under nuts then push other Strike side down aay a cee 10 Santa Fe Rx Installer s amp Owner s Manual SANTA FE Rx LAMINATE TOP KIT Please read these instructions before modifying the Santa Fe Rx to use the Laminated Top 1 Tools required A medium size phillips screwdriver 2 Remove the posts using the phillips screwdriver 3 Remove the release paper from the 1 diameter by 14 high bumper pad and attach it over the locating hole as indicated 4 Attach the 34 diameter by 1 high rubber bumpers to the outer holes as indicated using the phillips screwdriver and the screws provided 5 Place the laminated top so the holes in the bottom of the laminated top rests over the 34 diameter by 1 high rubber bumpers y2 diameter x 1 4 Locating high bumper N WA Hole Outer Holes er 34 diameter x 1 Posts pr high bumper 11 Santa Fe Rx Installer s amp Owner s Manual Santa Fe Rx Dehumidifier Limited Warranty WARRANTOR Therma Stor LLC PO Box 8680 Madison WI 53708 Telephone 1 800 533 7533 WHO IS COVERED This warranty extends only to the original residentia
2. ccccscesssscsssscesssssseeeeseeeseeees 4 5 OOIVICO is iii anette a eae h a E E 4 5A Waray ois cies csestccesdesedceidaacccvideccitabdas sdeaitaesdcsHesitactdenazceed 4 5 2 Technical description ccsccscscssesescssesssesssseeessessseecsees 4 iS IMOUDIGSMOOUNG e nann lca lect ectieelectccetectecsds 4 5 4 Refrigerant CharQing cccccecsceeseseeeeeeereessieeseesetees 5 5 5 Blower Replacement c ccccccesssscsssscseescssssssseessesessessees 5 5 6 Compressor Capacitor Replacement ccccsceseseseeees 5 5 6A Replacing A Burned Out Compressor c ccseessesesseeseesens 6 5 6B Replacing a Compressor Nonburn OUt cesesseeseeseens 6 5 7 Humidity Control 00 cee eseseseesssecessscssesseesseeessesessesaees 6 5 8 Defrost Thermostat ccccccccscssesssscsssscsssscssessecssseeessessees 6 5 9 Condensate PUMP c cccccssesesesssscssssssssscsssesecessesesseseees 6 B10 Relay 4262 4 sGk ed PAN Ao REEL AAE REALE AG 6 5 11 Low Pressure Contrl c cccccsssscsssscssesssessssessseceseessees 6 Wiring Diagrama seasiesccseseeescisesaetet en reesseendeetdeer raaa eesti 7 Service Parts List ccssscsesssesssessseessssesesssseessseesssansseaesess 8 Filter Frame Assembly cccccccscseesesssscssessecsesessssesssssssseesseees 9 Set Up Instructions ccceccscsceescssesssecsssessssecsssesssessseesatees 10 Laminate Top Kit cccccscessccsesssscsssecssesssssessesessessssessseesatees
3. The pump also contains a safety float switch If the pump fails this switch opens the compressor control circuit and stops water production before the reservoir overflows The compressor will stop but the blower will not 5 10 Relay The relay provides power to the compressor via the black wire Current passes through relay contacts between terminals 4 and 6 The contacts are closed when power is applied to relay terminals 0 and 1 by the dehumidistat pump safety defrost control and low pressure control are all closed If there is no continuity between terminals 4 and 6 when power is applied to terminal 0 and 1 by the control circuit the relay is defective and must be replaced The relay is also defective if there is continuity between 4 and 6 when no power is applied to 0 and 1 5 11 Low Pressure Control If the low side refrigerant pressure drops to 15 PSIG the low pressure control opens this opens the blower circuit and the control circuit that controls the compressor It is an automatically reset control it will close if the pressure rises to 37 PSIG It s primary function is to prevent damage to the compressor if a leak develops in the refrigeration system Santa Fe Rx Installer s amp Owner s Manual SANTA FE Rx WIRING DIAGRAM BLOWE SAFETY EMUMIDISTAT SWITCH SWITCH BLOWER MOTOR DENSATE LO PRESSURE jee CONTROL CAPACITOR COMPRESSOR COMP
4. 4021395 1 Evaporator Coil 16 4020955 1 Filter Drier 17 4023747 1 Hose Vinyl 19 ID x20 18 4023660 1 Humidity Controller 19 4021495 1 Knob 25 Shaft 20 4023857 1 Label Wiring Diagram not shown 21 4023868 1 Metal Top not shown 4024140 1 Laminated Top Kit optional 22 4022219 1 Low Pressure Control 23 1970010 1 Relay 25A 24 4025560 1 Rocker Switch For Fan 25 4023870 1 Safety Float Switch Remote Reservoir optional not shown e f H H n H H H e a Figure 3 Santa Fe Rx Installer s amp Owner s Manual SANTA FE Rx FILTER FRAME ASSEMBLY This kit attaches to the back of the Santa Fe Rx The back is the side where the air comes out of the lower section 1 Remove the protective plastic from the frame top amp sides Assemble the frame top Item 1 amp bottom Item 2 to the frame sides Items 3 with 8 screws Item 6 The frame bottom has 3 4 thick by 1 wide foam on one outer edge The frame top has 1 2 thick by 1 2 wide foam on the equivalent edge 2 Push the plastic nuts into the 6 square holes on the unit back If they are difficult to push in gently tap them in with a hammer or rubber mallet NOTE The service panel on the back of the unit 261 4 high x 181 2 wide held with 6 screws must remain in place when using this filter frame assembly DO NOT REMOVE 3 Place a rug or cardboard down and lay the Santa Fe Rx on its front Screw the frame to the Santa
5. Fe Rx back with 6 screws Item 6 into the plastic nuts starting with the middle screws Stand unit upright 4 Remove the 4 screws that attach the frame top to the frame sides 5 Attach the C shaped filter guides Items 4 to the inside of the frame sides with machine screws and lock nuts Items 5 amp 7 Place the nuts to the inside 6 Slide the air filter s into the filter guides from the top 7 Reattach the top 8 Reposition the Santa Fe Rx with the back of the unit at least 1 5 from a wall with the optional filter frame Without the filter frame at least 3 is required Filter Test The optional 95 efficiency and HEPA filters have long lives when prefitered by the standard pleated inlet filter they can last many years in certain conditions How long they last can however vary widely depending upon the following Unit run time air contamination level and standard inlet filter cleanliness Due to the optional filters expense it can be costly to change them prematurely The following test helps determine when they should be changed Air exiting the bottom rear of the unit enters the filter frame then passes through the optional filter and into the room If the filter is dirty air pressure builds up before the filter To check this pressure remove the plastic plug from the filter frame top you will feel air coming out of the hole with the unit running Place the ping pong ball that came with
6. from the incoming air and evaporates The evaporator operates in a flooded condition which means that all the evaporator tubes contain liquid refrigerant during normal operation A flooded evaporator should maintain constant pressure and temperature across the entire coil from inlet to outlet The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil The accumulator prevents any liquid refrigerant from reaching the compressor The compressor evacuates the cool refrigerant gas from the accumulator and compresses it to a high pressure and temperature gas to repeat the process 5 3 Troubleshooting No dehumidification Neither blower nor compressor run with AUTO FAN and humidity control turned ON 1 Unit unplugged or no power to outlet 2 Humidity control set too high or defective Sec 3 1 amp 5 7 3 Loose connection in internal wiring Fig 2 4 Safety float switch in remote reservoir has turned unit off Sec 2 5 No dehumidification Compressor does not run but blower runs with AUTO FAN and humidity control turned to ON 1 Defective compressor run capacitor Sec 5 6 2 Loose connection in compressor circuit See Fig 2 Santa Fe Rx Installer s amp Owner s Manual FOR HVAC INSTALLER ONLY 3 Defective compressor overload Sec 5 6A 4 Defective compressor Sec 5 6 5 Defrost thermostat open Sec 5 8 6 Defective relay Sec 5 10 7 Pump Safety switc
7. machine and adds 6 1 2 to the units depth It allows the choice of using either 95 efficient HEPA grade or activated carbon filters in addition to the standard filter These filters are accessible by removing the 4 screws from the filter frame top cover The 95 efficient filters MERV 14 as rated by ASHRAE 52 76 Dust Spot Test capture about 95 of all particles greater than 1 micron Actual filter size is 19 38 wide x 15 38 high x 3 75 deep Two filters are stacked to form a 32 high filter bank These filters can be tested for replacement using the optional filter test listed in Section 4 1B The HEPA media filter captures 99 97 of all particles 0 3 microns or larger that pass through it Actual filter size is 19 38 wide x 30 75 high x 3 75 deep These filters can be tested for replacement using the optional filter test listed in Section 4 1B Optional Carbon filter Pleated filter combination The carbon filter is actually a blend of activated carbon and potassium permanganate This blend removes the vast majority of gaseous contaminants encountered in most filtering applications The activated carbon removes the heavier volatile organics while the potassium permanganate removes the lower molecular weight contaminates The life of this disposable filter depends upon both the hours used and the contamination level The filter contains 8 7 pounds of active media 17 4 pounds with two filters Another advantage o
8. the filter frame on the hole and let go any marked regulation sized ping pong ball will work If the ball does not move or only bounces slightly and does not spin continuously the filter is clean enough for continued use If the ball floats above the hole and starts to spin and perhaps wobble within 30 seconds the filter needs to be changed Parts List Item No Quantity Description 1 1 Frame Top 2 1 Frame Bottom 3 2 Frame Side 4 2 Filter Guide C shaped 5 4 Machine Screw 8 32 x 1 2 long 6 15 Thread Forming Screw 8 18 x 1 2 long 1 spare 7 4 Lock Nut 8 32 8 10 Plastic Nut 4 spares 9 1 Ping Pong Ball used for Filter Test Save Santa Fe Rx Installer s amp Owner s Manual SANTA FE Rx SET UP INSTRUCTIONS Before operating this unit please read the Installers amp Owners Manual How to prepare the Santa Fe Rx for operation 1 Locate the unit per the manual 2 Cut the cable tie holding the cord and hose on top 3 Route the hose to a drain see manual 4 Dehumidistat is preset at the factory See manual for adjustment instructions 5 Blower switch is set in the off position at the factory See manual for blower operation options 6 Install the filter as shown in Figure Air flow arrow must point down 7 Lower the top down so the keyhole slots in the top drop over the posts Slide the top until the catch latches to the strike as shown in Figure
9. 11 Wali aMity 22 2253 265 sxiovis RRE 12 Read the installation operation and maintenance instructions carefully before installing and using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Santa Fe Rx Dehumidifier 1 Specifications Part Number 4023673 Model Santa Fe Rx Dehumidifier Electrical 110 120 VAC 6 3 Amps grounded Capacity 86 pints day 80 F 60 RH Operating Temp 65 F min 100 F max Range Air Flow 230 CFM 0 0 WG Refrigerant Charge 1 Ibs 14 oz R 22 Unit Size 20 D x 23 W 37 H w top Weight 130 Ibs 2 Installation 2 1 Location The Santa Fe Rx can be installed in a variety of locations to meet the owner s needs as listed below In all cases keep the following cautions in mind 1 It is designed to be installed INDOORS ONLY 2 If used near a pool or spa be certain there is NO chance the unit could roll into the water or be splashed and that it is plugged into a GROUND FAULT INTERRUPTER 3 DO NOT use the Santa Fe as a bench or table 4 Avoid discharging the air directly at people especially in pool areas Consider the following points when choosing a location for your Santa Fe Rx 1 The Santa Fe Rx is most effective if it is centrally located in the space to be dehumidified It is designed to be placed with its back 3 or more from a wall the air outlet is located at the lower portion of the back This will reduce nois
10. C voltmeter If voltage is resent go to step 3 If there is no voltage either the pump safety switch defrost thermostat low pressure control or relay are open or there is a loose connection in the continuity see the appropriate section if a defect is suspected N Se Check continuity between overload terminals 1 and 3 if there is none the overload may be tripped Wait 10 minutes and try again If there is still no continuity it is defective and must be replaced p Unplug the unit then replace the run capacitor with one of the same microfarad rating and equal or greater voltage rating If such a capacitor is unavailable a hard start kit sized for this compressor may be used If the compressor does not start and run correctly the compressor is defective and must be replaced Santa Fe Rx Installer s amp Owner s Manual FOR HVAC INSTALLER ONLY 5 6A Replacing a Burned out Compressor The refrigerant and oil mixture in a compressor is chemically very stable under normal operating conditions However when an electrical short occurs in the compressor motor the resulting high temperature arc causes a portion of the refrigerant oil mixture to break down into carbonaceous sludge a very corrosive acid and water These contaminants must be carefully removed otherwise even small residues will attack replacement compressor motors and cause failures Test the failed compressor oil with a test kit If it indicates a b
11. INSTALLER S amp OWNER S MANUAL HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNER Sant aFe Free standing dehumidification for your home E ncludes installation operating and safety instructions warranty information and all ancillary products ENERGY STAR Read and save these instructions nA Therma Stor uc P O Box 8680 Madison WI 53708 e TOLL FREE 1 800 533 7533 e www thermastor com sales thermastor com 2006 Therma Stor LLC e Manual P N TS 235 8 07 TABLE OF CONTENTS Table of Contents 1 Specifications cccccccescsssssssssesssesssssesssensssaesesseseesssessseenaes 2 2 Installati n 2 2A LOGAUOM sis eids A eesetiedeeeatiiinestiedsvaadedliaaiiins 2 2 2 Electrical Requirements cccccsessesesesssseessseessessseeaees 3 2 3 Condensate Removal c cccsccesssccsssscsssssssessseesssecsseeesees 2 2 4 Optional Reservoir COntainer cccccsseceessssesssseseeeeeees 3 2 5 Safety Overflow Switch ccccescscsssesssssssessseeesseseseeesees 3 3 OperatiON 56 nos cacada cascada dadeid aaraa aA EErEE e 3 3 1 TOP REMOVAI cccccccsscscsessessssseessssssesssseesscensesansesseseess 3 3 2 Humidity Control Adjustment 3 3 3 POW T SWIT ieia ra aE 3 A M iNteNane cccccccccssseseescssesssecessecessessssesssesseeesseseseneess 3 AeA Ait FING isisisi 3 A 1A Filter Options ccccscseessessseesssecsssssssssssseesseeeseeees 4 4 1B Optional Filter TeSt
12. Lifting off the top accesses the blower switch It is located near the humidity control dial Turning the blower switch to FAN ON will cause the blower to run continuously whether the unit is dehumidifying or not This function is desirable if the unit is used for air filtering 4 Maintenance 4 1 Air Filter The Santa Fe Rx is equipped with a standard MERV 11 65 Efficient disposable pleated fabric air filter Optional 95 efficiency 99 97 efficiency HEPA grade and activated carbon filters are available see Section 4 1A The standard filter is located beneath the removable top The filter is removed by lifting the front edge up first then the back It should be checked every 6 months Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency f dirty the pleated fabric filter can generally be vacuumed cleaned several times before needing replacement Replacement filters can be ordered from the factory or purchased locally if available Its nominal size is 16 x 20 x 2 thick Its efficiency is 65 per ASHRAE std 52 1 1992 DO NOT operate the unit without the filters or with a less effective filter The heat exchange coils inside the unit could become clogged which would reduce performance and require disassembly to clean Santa Fe Rx Installer s amp Owner s Manual FOR HVAC INSTALLER ONLY 4 1A Filter Options An optional filter frame is available that attaches to the back of the
13. ONENT WIRING rc Therma Stor uc PART NO 4025857 Figure 2 Electrical Schematic of the Santa Fe Rx Dehumidifier 7 Santa Fe Rx Installer s amp Owner s Manual SANTA FE Rx SERVICE PARTS LIST o To order contact your reseller or call 1 800 533 7533 ITEM PART NO QTY DESCRIPTION 1 4022254 1 Accumulator 2 4021475 1 Air Filter 2 x 16 x 20 Nominal 4024145 1 Air Filter 4 x 20 x 32 Nominal HEPA optional requires kit Item 3 4023612 2 Air Filter 3 x 16 x 20 Nominal Carbon optional requires kit Item 3 order with Pleated Filter 4024264 4024264 2 Air Filter 1 x 16 x 20 Nominal order with Carbon Filter 4023612 4022164 2 Air Filter 4 x 16 x 20 Nominal 95 optional requires kit Item 3 3 4023869 1 Air Filter Frame Kit optional not shown 4 4022037 1 Blower with Capacitor 350CFM 115V 5 4023871 1 Top Catch amp Strike Set not shown 6 4024912 1 Capacitor Run 25 Mfd 7 4021589 2 Capillary Tube 050 I D X 144 0 D X 28 Long 8 4023604 4 Caster Swivel 2 9 4021396 1 Condenser Coil 10 4023648 1 Compressor Carlyle 7 0 Kbtu Carlyle p n EAA070111A ITEM PARTNO QTY DESCRIPTION 4020530 3 Compressor Mounting Grommet 11 4023649 1 Condensate Pump Low Profile 12 4023661 1 Cord Wire Harness not shown 13 4021470 1 Defrost Control Thermostat 14 4021648 1 Defrost Thermostat Mounting Clip 15
14. e and the likelihood that discharge air will blow directly at someone The water removed by the APD will be pumped through the white 20 long hose coming from under its base The hose about the diameter of a TV coaxial cable must be routed to a drain or outside It can pump 15 above the unit and can be extended see section 2 3 The top can serve as a light duty table maximum load 20 Ibs but it must be removed periodically to check the air filter N Se p gt 2 2 Electrical Requirements The Santa Fe Rx plugs into a common grounded outlet on a 15 Amp circuit It draws between 6 and 7 Amps under normal operating conditions If used in a wet area pool spa room or basement prone to flooding a ground fault interrupter protected circuit is required 2 3 Condensate Removal The Santa Fe Rx is equipped with a condensate pump to remove the water that is condensed during dehumidification This allows the water to be discharged to a distant location or to be pumped up to 15 above the Santa Fe Rx Santa Fe Rx Installer s amp Owner s Manual SAFETY PRECAUTIONS The water is discharged through a 20 long white hose coming from the unit bottom The hose is about the diameter of a TV coaxial cable and can be routed in much the same way If a drain is not convenient a small hole can be drilled through the floor or wall to access a drain or outside The hose can be extended if needed it should however b
15. e extended with a hose of larger inner diameter 1 4 D or greater to avoid overloading the pump Larger diameter hose is available from the factory or may be purchased from many hardware stores If the hose can not be routed to a drain or outside a reservoir container with an overflow switch can be used If the hose is routed outside it must exit the building with a downward slant This will allow the water in the hose to drain from it when the pump shuts off preventing it from freezing Pump failure will cause the unit to stop dehumidifying via a safety switch 2 4 Optional Reservoir Container If the condensate discharge hose cannot be routed to a drain or outside it can empty into a conveniently located container This container supplied by the customer can be any size greater than 1 2 gallon It can be emptied manually or by a pump supplied by the customer CAUTION It is strongly recommended that a safety overflow switch be used to prevent the container from overflowing and causing potentially costly water damage 2 5 Safety Overflow Switch A Safety Overflow Switch is available from the factory see parts list It consists of a float switch on a weighted cord with a male female piggyback plug The cord is secured to the container with the float and weight inside the weight is separated from the float and container wall 3 Operation 3 1 Top Removal The top of the unit must be removed to access the humidity con
16. f this blend versus an all carbon filter is that this one changes color as it loads up with contaminates It starts out black then turns pink then brown and finally white It is best changed when it passes the brown stage and begins to turn white It has lost most of its effectiveness at that point Actual filter size of the carbon filter is 19 38 wide x 15 38 high x 2 88 deep The 88 deep pleated filter is the same nominal size and is installed downstream of the carbon dust The two filter combos are stacked to form a 32 high filter bank 4 1B Optional Filter Test The optional 95 efficiency and HEPA filters have long lives when prefiltered by the standard MERV 11 65 efficient pleated inlet filter they can last many years in certain conditions How long they last can however vary widely depending upon the following unit run time air contamination level and standard inlet filter cleanliness Given the expense of the optional filter it can be costly to change them prematurely The following test helps determine when they should be changed Air exiting the bottom rear of the unit enters the filter frame then passes through the optional filter and into the room If the filter is dirty air pressure builds up before the filter To check this pressure remove the plastic plug from the filter frame top you will feel air coming out of the hole with the unit running Place the ping pong ball that came with the filter frame on t
17. h open Sec 5 9 CONDENSER Blower runs with AUTO FAN but compressor cycles on amp off 1 Low ambient temperature and or humidity causing unit to cycle through defrost mode 2 Defective compressor overload Sec 5 6A 3 Defective compressor Sec 5 6 4 Defrost thermostat defective Sec 5 8 Blower does not run with fan switch in either position Compressor runs briefly but cycles on amp off 1 Loose connection in blower circuit see Fig 2 2 Obstruction prevents impeller rotation 3 Defective blower Sec 5 5 4 Blower switch defective Evaporator coil frosted continuously low dehumidifying capacity 1 Defrost thermostat loose or defective Sec 5 8 2 Low refrigerant charge 3 Dirty air filter or air flow restricted Sec 4 1B 5 4 Refrigerant Charging If the refrigerant charge is lost due to service or a leak a new charge must be accurately weighed in If any of the old charge is left in the system it must be removed before weighing in the new charge Follow EPA recovery regulations Refer to the unit nameplate for the correct charge weight and refrigerant type 5 5 Blower Replacement The centrifugal blower has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug the power cord 2 Remove the unit top 3 If optional HEPA 95 efficient or carbon filters are attached to the unit back the filter s and their frame m
18. he hole and let go any marked regulation sized ping pong ball will work If the ball does not move or only bounces slightly and does not spin continuously the filter is clean enough for continued use If the ball floats above the hole and starts to spin and perhaps wobble within 30 seconds the filter needs to be changed 5 Service CAUTION Servicing the Santa Fe with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qualified service people should service this unit 5 1 Warranty A warranty certificate has been enclosed with this unit Read it before any repair is initiated If a warranty repair is required call the factory first at 1 800 533 7533 for warranty claim authorization and technical assistance 5 2 Technical Description The Santa Fe RX uses a refrigeration system similar to an air conditioner s to remove heat and moisture from incoming air and add heat to the air that is discharged see figure 1 Hot high pressure refrigerant gas is routed from the compressor to the condenser coil The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat
19. l end user of the SANTA FE RX Dehumidifier and may not be assigned or transferred FIRST YEAR WARRANTY Therma Stor LLC warrants that for one 1 year the SANTA FE RX dehumidifier will operate free from any defects in materials and workmanship or Therma Stor LLC will at its option repair or replace the defective part s free of any charge SECOND THROUGH FIFTH YEAR WARRANTY Therma Stor LLC further warrants that for a period of five 5 years the condenser evaporator and compressor of the SANTA FE RX dehumidifier will operate free of any defects in material or workmanship or Therma Stor LLC at its option will repair or replace the defective part s provided that all labor and transportation charges for the part s shall be borne by the end user END USER RESPONSIBILITIES Warranty service must be performed by a Servicer authorized by Therma Stor LLC If the End user is unable to locate or obtain warranty service from an authorized Servicer he should call Therma Stor LLC at the above number and ask for the Therma Stor LLC Service Department which will then arrange for covered warranty service Warranty service will be performed during normal working hours The End user must present proof of purchase lease upon request by use of the warranty card or other reasonable and reliable means The end user is responsible for normal care This warranty only applies to residential applications and does not cover any defect malf
20. s do not allow limitations on how long an implied warranty lasts and some do not allow the exclusion or limitation of incidental or consequential damages so one or both of these limitation may not apply to you LEGAL RIGHTS This warranty gives you specific legal rights and you may also have other rights which vary from state to state Santa Fe Rx Installer s amp Owner s Manual Therma Stor c Information in this document is subject to change without notice No part of PO Box 8680 e Madison WI 53708 this document may be reproduced or transmitted in any form or by any means Phone 608 222 5301 Fax 608 222 1447 electronic or mechanical for any purpose without the express written permission Web www thermastor com Email sales thermastor com of Therma Stor LLC 2006 Therma Stor LLC All rights reserved
21. trol knob blower switch and standard air filter The standard metal top is removed by pulling it horizontally toward the front about 3 4 then lifting it upward the unit front is opposite from the side that the air comes out 3 2 Humidity Control Adjustment The humidity control knob is located under the removable top top must be lifted off to access Turning the knob clockwise lowers humidity Turning it counter clockwise to the stop shuts it off The dehumidifier will run continuously until the relative humidity RH is reduced to the humidity control setting Setting the humidity control to lower RH levels will NOT increase the unit s dehumidification rate it will simply run longer to reduce the area s RH to the setting The Santa Fe Rx unit and refrigerant based dehumidifiers in general will reduce a warm space s RH to a lower level than that of a cool space For example the Santa Fe Rx may reduce an 80 F space to 30 RH However if the same space is 65 F it may only reduce to a 40 RH It is therefore pointless to set the humidity control to excessively low levels in cool rooms Doing so will result in long periods of ineffective dehumidifier run time and will consume electricity needlessly A quality humidity meter is supplied upon return of the warranty registration card it is recommended to accurately monitor humidity levels Additional meters are available for purchase from the factory 3 3 Blower Switch
22. unction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLCs reasonable control lt j SKS LIMITATIONS AND EXCLUSIONS If any SANTA FE RX Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable there to but all warranty periods will be extended by the period of time if any that the SANTA FE RX Dehumidifier is out of service while awaiting covered warranty service SSE RESE SRR NV SKK RRR LLL Upon the expiration of the written warranty applicable to the santa fe rx dehumidifier or any part thereof all other warranties implied by law including merchantability and fitness for a particular purpose shall also expire All warranties made by therma stor lic are set forth herein and no claim may be made against therma stor llc based on any oral warranty In no event shall therma stor lic in connection with the sale installation use repair or replacement of any santa fe rx dehumidifier or part thereof be liable under any legal theory for any special indirect or consequential damages including without limitation water damage the end user should take precautions against same lost profits delay or loss of use or damage to any real or personal property x SLS NIIS Some state
23. urn out follow EPA regulations for disposing of the old refrigerant and oil Follow standard procedures for replacing a burned out compressor These would include replacement of the liquid line filter drier and addition of an oversized suction line filter drier if it was a running burn out Several changes of the liquid and suction filter driers may be necessary to cleanse the system 5 6B Replacing a Compressor Nonburn Out Dispose of the old refrigerant per EPA guidelines Replace the compressor and liquid line filter drier Weigh in the refrigerant quantity listed on the nameplate 5 7 Humidity Control The humidity control is an adjustable switch that closes when the relative humidity of the air in which it is located rises to the dial set point It opens when the RH drops 4 to 6 below the set point 5 8 Defrost Thermostat The defrost thermostat is attached to the refrigerant suction tube between the accumulator and compressor It will automatically shut the compressor off if the low side refrigerant temperature drops due to excessive frost formation on the evaporator coil The blower will continue to run causing air to flow through the evaporator coil and melt the ice When the ice has melted the evaporator temperature will rise and the thermostat will restart the compressor 5 9 Condensate Pump Condensate is automatically pumped to a remote location when the water level in the pump s reservoir rises to close the float switch
24. ust be removed 4 Remove the back cover 4 screws 5 Remove the cabinet 6 screws Disconnect the blower leads black from the black wire at wire nut and white from the run capacitor Remove the foam pieces at the blower outlet at the bottom back to access the blower screws Remove the 4 screws holding the blower outlet flange and remove the blower Reassembling with the new blower is the above procedure reversed o N oo 5 6 Compressor Capacitor Replacement CAUTION ELECTRIC SHOCK HAZARD Electrical power must be present to perform some tests these test should be performed by a qualified service person This compressor run capacitor is accessed by following steps 1 through 4 in section 5 5 on blower replacement the compressor is accessed by following steps 1 through 5 This compressor is equipped with a two terminal external overload run capacitor but no start capacitor or relay see Fig 2 Perform the following tests if the blower runs but the compressor does not with the AUTO FAN and the humidity control ON 1 Unplug the unit follow steps 1 through 5 of section 5 5 to access the compressor Remove the electrical connection cover on the compressor top Plug in the unit and turn the humidity control to ON If the compressor tries to start but cycles on the over load go to step 4 If the compressor remains silent check for 110 volts from compressor terminal R to overload terminal 3 using an A