Home

Tecumseh VSAG511ZXTXM Performance Data Sheet

image

Contents

1. TECUMSEH HERMETIC CONDENSING UNIT Model VSAGS11ZXTXM BOM 32T2642 2 Air Cooled 2 34 HP Application Low Temp Refrigerant R404A 00 16 00 LIQUID 1 2 SUCTION 7 8 i 31 50 Ie VSAG511ZXTXM TPC__ preliminary October 14 2011 H Dimensions inch Line connections Pumpdown Air flow Oil Ch Gross weight VSAG511ZXTXM L Ww H Suction Liquid 90 90 F SCFM Oz Lbs 25 00 33 50 19 44 7 8 Sweat 1 2 Sweat 20 44 1525 55 200 Mounting Holes 16 00 x 31 50 Factory charge 20 psig dry air MUST BE EVACUATED Evaporator Ambient Temperatures a CO BTUH Wats Head Cond T BTU J Walls Head CondT BTOH Walls Head Cond T BTUH Walls Head CondT 7 301 118 8 0 304 118 308 119 311 120 315 121 20 15 319 122 114 ee em 4 on 2 5 ae 2510 a 13600 2600 5 365 15000 2680 0 130 Performance 60 Hz Return gas 40 F SubCooling 5 F PRELIMINARY PERFORMANCE DATA 11600 F 120 eoj e r VSAG511ZXTXM TPC__ preliminary October 14 2011 Parts Specifications Unit BOM paraz Fan Motor Unit MODEL Fan Motor Qty Fan Motor RLA Refrigeration RANGE _ 40 F to 10 F Fan Blade Design Pressure Low 181 Fan Guard Design Pressure High 450 Shroud Volts HZ Ph 200 230V 3 6
2. 0HZ Voltage Range High Pressure switch Min Circuit Ampacity Low Pressure Control 84026 2 Max Fuse Size Dual Pressure Conrol Compressor MODEL Condenser 50858 Compressor BOM Head Master Vave ss Compressor LRA Bo Check Valve OoOo OE Compressor RLA Process Valve Oo O Po Liquid Vave Pp OverLoad Suction Valve Relay E E Run Capacitor Receiver Run Capacitor Rating Receiver Qty Go OE Start Capacitor P Accumulator Start Capacitor Rating Liquid Filter Contactor Sight Glass i Suction Filter Unit Drawing ess Wiring Diagram CrankCase Heater Po IMPORTANT N OT E S COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR ALLOW TIME FOR RESET USE COPPER CONDUCTORS ONLY EMPLOYER DES CONDUCTEUERS DE CUIVER FIELD WIRING NOTES 1 ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES CONNECT INCOMING POWER LEADS FROM POWER SUPPLY SEULEMENT TO L1 L2 AND L3 IN COMPRESSOR CONTACTOR OR TO L1 L2 AND L3 IN DISCONNECT SWITCH IF PROVIDED USE COOPER CONDUCTORS ONLY EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT PROVIDE EQUIPMENT GROUNDING CONDUCTOR USE 75 C MIN WIRING IF REQUIRED INSTALL SYSTEM REMOTE CONTROL BETWEEN P1 AND P2 IN TERMINAL BLOCK AND REMOVE THE JUMPER FAN1 FAN 2 GENERAL NOTES A CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR ALLOW TIME FOR RE
3. SET SOLENOID M HQUID INJECTION COMPRESSOR CONTACTOR NO AUXILIARY SWITCH FFC1 FFC2 FAN CONTROL 1 2 COMPRESSOR HP or Lp CONTACTOR COIL gt 3 FFCt FFC2 see note A Lp LOW PRESSURE CONTROL TERMINAL EN BOARD p a 6 Serre 2ra RECEIVER Sm ot S HP HEATER THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208 230 60 3 Ls 13 oT 0 DISCHARGE LINE THERMOSTAT Le 2 u 1 i FACTORY COMPONENTS GRD CRANK CASE 4 H S L2 3 OPTIONAL FACTORY COMPONENTS COMPRESSOR xX CONTACTOR TT UT mo m OPTIONAL FIELD COMPONENTS COMPRESSOR ERMINAL i CONDENSING UNIT WIRING 230V 60Hz 3 Ph l OAN BLACK Liquid Injection Solenoid Fan control RED REL REVISION YELLOW WD23 2FL DEC 21 2010

Download Pdf Manuals

image

Related Search

Related Contents

Premier Mounts CPD10WALLARM User's Manual  取扱説明書 赤外線ハウジング一体型カメラ  General Ledger  Your Ademco Fir&Burglar Alarm System  

Copyright © All rights reserved.