Home
Taylor Scale TE150 User's Manual
Contents
1. General Operation cont OVERLOAD The scale can be overloaded by a maximum of 5 above the scale s capacity as follows Max Load TE150 157 4 lb 71 4 kg TE400 420 lb 190 4 kg POWER OFF To turn the scale off press the OFF button Calibration Function Occasionally the scale s accuracy should be verified by measuring a known weight of the scale s approximate capacity Tare the scale by pressing ZERO place the weight on the platform and note the reading Calibrate the scale if necessary Calibration Procedure You must use a CALIBRATED weight ONLY to properly recalibrate the scale e For the TE150 use a 150 lb calibrated weight or 60 kg if operating in kilos For the TE400 use a 400 lb calibrated weight or 150 kg if operating in kilos 1 While the scale is off press and hold down the TARE HOLD and lb kg buttons While holding down both these buttons press the ON button to turn the scale on When the display shows 8888 gt CAL the scale is in calibration mode 2 Release the buttons The display will show CX with a number CX150 for the TE150 CX400 for the TE400 Next the display will show a number the zero count between 4700 and 6000 Note if operating the scale in kilograms the scale will instead show C60 for the TE150 or C150 for the TE400 If the zero count is outside the range please contact customer service 3 Press the TARE HOLD b
2. DO NOT clean the unit with an abrasive or corrosive material This may scratch the plastic parts and corrode the electronic circuits 4 DO NOT subject the units to excessive force shock dust temperature or humidity This may result in malfunction shorter electronic life span damaged battery and distorted parts 5 DO NOT tamper with the unit s internal components Doing so will invalidate the warranty on the units and may cause damage The unit contains no user serviceable parts Only use fresh batteries as old batteries may leak and cause damage to the unit Remove the batteries if the scale will not be used for a long period of time 8 DO NOT dispose of batteries in fire Disposing of this product in fire could cause batteries to explode or leak Specifications Platform Size 8 1 16 x 5 Power 120V adaptor included or six 6 AA batteries not included Dimensions 12 1 4 x 12 x 2 1 8 Weight 9 3 4 lbs 4 4 kgs Operating Temperature Range 40 F to 104 F Accuracy 1 1 division Capacity TE150 150 lbs x 0 2 lb 150 Ibs x Ib 68 kgs x 0 1 kg TE400 400 lbs x 0 5 Ib 400 Ibs x lb 181 kgs x 0 2 kg Overload TE150 157 4 lbs 71 4 kgs TE400 420 lbs 190 4 kgs Platform TE150 Stainless steel TE400 Tread painted steel One Year Limited Warranty This product is warranted against defects in materials or workmanship for one 1 year from date of original purchase It does not cover damages or
3. platform the display will show 50 0 J the minus value exceeds 99 9 lbs the display will show To reset the minus warhe to zero press the TARE HOLD button HOLD OPERATION The HOLD function may be used to lock the weight on the display even after the load is removed from the platform To use the hold function press and hold the HOLD button for 3 seconds The display will show H on indicating the hold feature is on To cancel the hold function press and hold the HOLD button for 3 seconds The display will show H oF indicating the hold feature is off When the Hold function is on the weight will continue to display even after the item has been removed from the platform UNIT CONVERSION Press the Ib kg button on the front panel to switch between pound and kilogram units of measurement A small triangle appears in the upper left corner of the display for kg mode or on the lower left corner for lb mode
4. eps 1 and 2 The LCD shows 8888 then A_on then 0 0 The auto off is enabled Battery Installation The Digital Receiving Scale operates with 6 AA batteries not included alkaline recommended 1 Remove the battery Replace the Place the scale upright on a flat surface Lift the platform cover from the top of the scale compartment door and z insert batteries into the K i compartment compartment door Replace the platform cover on the scale Mounting the Scale 1 2 Mount the bracket to a wall using 2 screws not included that are appropriate anchors for the mounting surface Lower the control panel into the mounted bracket Insert the flat tip of the included screws through the round holes in the mounting bracket Drive the screws into the existing threaded hold in the lower half of the control panel to secure the control panel to the bracket LLL YOUR SCALE IS NOW READY FOR USE Display and Function oz g kg Display Button sai kg m 7 oat L Ib LD Ib Display LCD Hold Display Button sen General Operation POWER To turn the scale on press the button marked ON The display will first show 8888 followed by 0 0 The scale is ready for use WEIGHING When the display shows 0 0 the scale is ready to weigh an object If the object exceeds the capacity of the scale by more than 5 the display will show oooo for
5. orm Coil Cord LCD Display J x z Control Panel j X i Tare Hold Button off On Button Button Main Features e LCD Screen 1 0 digits display weight e Tare Hold Button When pressed once the scale will tare zero out the weight on the platform When presses and held for 3 seconds the weight will continue to display even after the weight is removed e Ib kg Button When pressed the weight display converts from pounds to kilograms On Button When pressed turns the scale ON Off Button When pressed turns the scale OFF e Auto Shut Off Powers off after 2 minutes of non use e Low Battery Indicator Appears on LCD screen when battery is low Cord 6 coiled cord e Control Panel Can be stationary or mounted to a wall e Platform Model TE150 has a stainless steel finish Model TE400 has a tread painted steel finish Before You Begin 1 Remove the scale from its box along with the control panel and the 120V adaptor 2 If using the 120V adaptor plug one end into the receptacle connector at the rear of the scale Insert the other end the transformer into a 120V outlet Auto Shut Off Feature To disable the 2 minute auto shut off feature 1 While the scale is off press and hold Ib kg then press ON 2 The LCD shows 8888 then A_oF Release the buttons The scale shows will show 0 0 The auto off is disabled 3 To enable the auto off feature repeat St
6. overload Until the overload condition is reached additional objects may be placed on the platform The display will show the sum of the weights of all the objects When one of multiple objects is removed from the platform the weight of the remaining objects will display TARE OPERATION To tare zero out a load on the platform example the weight of a container press the TARE HOLD button The display will show the value 0 0 During the TARE mode a new item can be added to the platform The display will show the sum of the weights of the added items Another item may be added if desired The display will show the sum of all additional item weights above and beyond the tared out load TARE CAPABILITY A load of up to the capacity of the scale can be tared zeroed out while still allowing the weighing of an additional object up to the full capacity of the scale Example Model TE150 has a capacity of 150 lbs If an item weighing 20 pounds is on the scale and the weight is tared zeroed out and additional load or loads of up to 130 Ibs can be weighed On a 10 pound scale TE10 a load of 5 lbs 50 can be tared out MINUS WEIGHT If a weight is tared zeroed out and is then removed from the platform the display will show a minus value For example if a load of 50 lbs is placed on the platform and the TARE HOLD button is pressed the display will show 0 0 If the weight is then removed from the
7. utton The display will show XXX0 4 Place a calibrated weight on the scale platform e For the TE150 use a 150lb or 60 kg calibrated weight e For the TE400 use a 400 lb or 150 kg calibrated weight The display will show a number between 1800 and 2300 the span count Note the span count must be stable on the display before proceeding to step 5 If the span count is outside this range please contact customer service 5 Press the TARE HOLD button The following will appear on the display e For the TE150 the display will show C150 gt End gt 150 0 or C60 gt End gt 60 0 if operating in kilograms e For the TE400 the display will show C400 gt End gt 400 0 or C120 gt End gt 120 0 if operating in kilograms 6 The calibration is complete Remove the weight from the scale Display Signals LCD Shows Low Battery eoeeeeeeeeeeeeeeeee bAtt Load is greater than Maximum Overload eeeeeeee0e0e00 0000 Precautions This scale is engineered to give you years of satisfactory service if you handle it carefully Here are a few precautions 1 Always read instructions thoroughly to ensure that you have the full benefit of all the unit s features 2 DO NOT immerse unit in water as doing so will cause damage to internal components and void the warranty If you spill liquid on it dry it immediately with a soft lint free cloth 3
8. wear resulting from accident misuse abuse or amend adjustment and or repair Should this product require service or replacement at our option while under warranty please pack the item carefully and return it prepaid along with receipt showing date of purchase and a note explaining reason for return to Taylor Precision Products 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 Customer Service Phone 1 800 225 4834 Customer Service Fax 1 575 526 4347 www taylorusa com There are no expressed warranties except as listed above This warranty gives you specific legal rights and you may also have other rights which vary from state to state 2009 Taylor Precision Products and its affiliated companies all rights reserved Taylor and Leading the Way in Accuracy are registered trademarks of Taylor Precision Products and its affiliated companies All rights reserved N Made to our exact specifications in China NOT LEGAL FOR TRADE TE150 TE400 11 09 TAYLOR TE150 TE400 Digital Receiving Scale Leading the Way in Accuracy Model TE400 Model TE150 Instruction Manual Thank you for purchasing a Taylor Digital Receiving Scale Your scale is an example of superior design and craftsmanship In order to optimize its function be sure the read this instruction manual carefully before use Keep instructions handy for future reference Description of Parts Model TE400 Shown Platf
Download Pdf Manuals
Related Search
Related Contents
KitchenAid KCS12KLLS Use and Care Manual Ventura Dokument Installation Instructions Instructions d`Installation Instrucciones de IE-703116-MC-EM1 In-Circuit Emulator Option Board UM ALEOS User Guide 4.0.9.book MANUAL DO USUÁRIO Compex MI-FITNESS® Frigidaire FPGC3087MS Product Specifications Sheet Sony VAIO VPCSB4AFX scheda tecnica Copyright © All rights reserved.