Home
Sunrise Medical Guardian Easytrack System 900-0880 User's Manual
Contents
1. a Guardian Easytrack System We want to hear your guestions or comments about this manual the safety and reliability of your Easytrack System and the service you receive from your Sunrise Medical Supplier Please feel free to write or call us at the address and telephone number below Sunrise Medical Customer Service Department 7477 East Dry Creek Parkway Longmont Colorado 80503 303 218 4600 or 800 333 4000 FOR ANSWERS TO YOUR OUESTIONS Your authorized supplier knows your Easytrack System best and can answer most of your guestions about its safety use and maintenance For future reference fill in the following Supplier Address Telephone Serial Date Purchased Bath Base Kit Important Safeguards 3 IMPORTANT SAFEGUARDS AWARNING Do not operate this eguipment without first reading and understanding this manual AWARNING Should you be unable to understand the warnings cautions and instructions contact our technical support or your local dealer before attempting to use this eguipment otherwise injury or damage may result Important information is highlighted by these terms A WARNING Notices as used in the manual apply to hazards or unsafe practices which could result in serious bodily harm CAUTION Notices as used in this manual apply to hazards or unsafe practices which could result in minor personal injury or property damage NOTES Highlight procedures and contain informat
2. the bath base rail out of the box and place it on its supports or screws that hold the metal anchor to allow the rail to extend and retract freely to fit on your tub Figure 2 Using the same key loosen the plas tic post bath base so that it will w slide easily Figure 3 4 Place the bath base rail on the edge of the tub next to the wall and extend the base so that it reaches each corner Figure 4 OI end of the tub Figure 5 Slide the plastic post base so that it is approximately 16 18 from the NOTE Edge of the bath tub must be thoroughly cleaned and dried before placing the bath base on the tub An Easytrack Bath Base that has been installed on an unclean or wet surface may cause injury or damage 6 Once the bath base is in place tight en the metal anchor inside with the allen key DO NOT OVER TIGHTEN 7 Tighten the post base in place with the Allen key DO NOT OVER TIGHTEN The post base should be snug and not able to slide once tightened NOTE Round foot pads under the bath base must be in contact with the tub com pletely The edge of the foot pad cannot be partially off the corner of the tub See Requirements section Figure 1 1240 Figure 5 Bath Base Kit 6 Assembly of Bath Base Kit 8 Measure the distance between the post base and the end of the bath base rail Cut and install the blue bath base cover into the bath base
3. Guardian Easytrack System Installation Bath Base Kit Assembly e Model 900 0880 Instruction Manual SUNRISE MEDICAL 2 Introduction TABLE OF CONTENTS INtrOductOonssa sst E TTI Ne HT MET 2 Important Safeguards ss ssse sia L ase e aR eaat 3 Requirements n sa musaa LRK Saa s cuadsvedtens Mucseensecea Saa N 4 Kit Contents amp Part Numbers 5 Assembly of Bath Base Kit 5 Bath Base Kit Specifications ssccscescsccsescetecaszssecedesccessscccous cdetssugeccescsccesees 8 Mantenan g us uuu ua uu uu un u SS uuu ke nine 8 Easytrack Products amp Accessories 10 Warranty resdan ennn saaa eao Mian S a A a aaa sassa huss 11 AWARNING This manual contains important safety and maintenance instructions Please read it carefully before using your Easytrack System and refer to it as often as needed for safe and efficient use If you have guestions regarding the safe use and or assembly maintenance or specifications of your Easytrack System you should call Customer Service at 800 333 4000 303 218 4600 or from Canada at 800 263 3390 For service and repair remember your authorized Sunrise supplier is able to provide the assistance you need Save this manual for future reference SUNRISE LISTENS Thank you for choosing
4. ack System Installing a post directly under a joist or truss is not reguired but preferable Floor Reguirements Bath Reguirements Ensure your tub is made of porcelain or metal and has sufficient structure underneath the tub to withstand the Supporting 1 5 min N Ensure flooring meets local building code standards Termites or water fs damage may affect the structure of the floor gt Ensure floor is clear of any dust grease water or any foreign substance Floor must not have a slope of more X 12 300mm 24 600mm 36 900mm 48 1200mm than 0 5 See drawing below to Y 0 10 2 6mm 0 21 5 2mm 0 31 7 9mm 0 42 10 5mm determine the floor slope Use a level or contact a contractor if unsure of floor slope Structure weight required see drawing below If you are unsure of the structural integrity of the tub contact the manu facturer or a contractor to evaluate the structure k 53 65 Ensure you have 3 of ledge space 1350 1650mm available on each end of the tub see drawing The round foot on the bath base must entirely be in contact with the tub ledge The tub length must be between 53 65 1350 1650 mm Any protrusion from the wall next to the tub must be removed to provide space for the post A molded plastic tub with a protruding wall may obstruct the post or base if there is not a straight line between the corners of the tub Tub must be clean of any soap
5. ctions should be reported in writing to your supplier Upon receipt of your Easytrack Bath Base Kit 1 U W N Make sure you received all components listed in Figure 1 Inspect all parts for possible damage in transit Ensure all components are in working order Repair replace any faulty parts Keep a log of any repair replacement reguired Item Number 900 0880 Weight Capacity 440lbs 200 kg Length of Base Rail 53 65 1350 1650mm Length of Post 67 90 5 1700 2300mm Post base travel zone 10 24 250 610mm Material Anodized Aluminum Stainless Steel Weight 25 5 lbs 11 5 kg Ceiling Plate 20 510 mm Bath Base Kit Maintenance Before each time you use the Easytrack Bath Base Kit 1 Clean the outside and inside of the rail and wipe out any water in the rail Failure to do so for a long period of time can cause corrosion that will weaken the rail Check with the level if the posts are straight In they are not straight remove rail and reinstall posts see Assembly instructions Check that the rail is secure in place Press the rail upwards to make sure that the rail is locked onto the post Check for any appearance of damage If there is apparent damage do not use the Easytrack System Make sure the red zone at t
6. he top of the post is not visible If the red zone is visi ble tighten posts according to the assembly instructions Every month 1 2 Use level supplied to ensure all posts are straight Clean inside of rail with a damp cloth to ensure there is no dust or grease build up inside of rail Make sure the red zone is not visible If red zone is visible tighten posts according to assembly instructions Check to ensure you still have all your original parts If any parts are missing they should be replaced BEFORE USING THE EASYTRACK AGAIN Check to make sure that the trolley in the rail moves freely Trolley may need to be cleaned or replaced Check for the appearance of rust If rust is starting to appear simply scrub the piece clean Examine all joints and pieces for wear and fatigue Replace any part that looks dam aged or worn Document inspection and any repairs If eguipment is moved on a regular basis 1 2 Make sure all components are accounted for Check Requirements and Important Safeguards before reinstalling the Easytrack System Make sure the padding on the foot and top plate is clear of any foreign substance and is not damaged If neoprene rubber on either top or bottom plate appears dam aged then the plate must be replaced 4 Make sure the level is still working Look for signs of wear or breakage on all parts Replace any parts that appear worn or damaged AWARNING Follow guidelines
7. in your portable lift manual for maintenance and procedures on the Lift Bath Base Kit 10 Easytrack Products amp Accessories EASYTRACK PRODUCTS amp ACCESSORIES Description Part Easytrack 2 Post System ooo u aa a a Aaa a a aa a nanna isnin 92000 Easytrack 3 Post System sisses asos ana m ananaw a Eiaa iinei 93000 Easytrack 4 POSt SYstem sisssse ton kassaan as aa ma kA ASSA eee MA KAAN N Vaa TUNA aak kraai 94000 Easytrack 2 Post with Tub Bracket 92001 Easytrack 3 Post with Tub Bracket 93001 Easytrack Portable Carry Bag ccccssssseeccccceesseeccceeeeseeeccseeesseecceseeeeeeees 92341 Bath Base Kit Warranty 11 WARRANTY This warranty is extended only to the original purchaser user of Sunrise products Sunrise Medical Inc warrants its products to be free from defects in material under normal use and service and will within the periods stated below from the date of purchase If within such warranty period any such product shall be proven to be defective such product shall be repaired or replaced at Sunrise Medical s option This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product Sunrise Medical s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and or rep
8. ion which assist the operator in understanding the information contained in this manual NOTE The information contained in this document is subject to change without notice SAVE THESE INSTRUCTIONS AND KEEP WITH EASYTRACK AT ALL TIMES AWARNING The Easytrack System and its accessories are intended to be used as an assistive device for transferring a person between the posts The Easytrack system is only to be used with the Guardian Voyager Portable lift AWARNING USE ONLY AS INTENDED This product may cause serious injury if not installed and operated according to the instruction manual Failure to observe warnings listed below could result in serious injury Before You Install the Easytrack AWARNING e Carefully inspect product upon arrival If any pieces are missing or appear damaged do not install Contact your local supplier for further instructions e If you are unsure of the strength or stability of your floor and or ceiling do not install the Easytrack System consult you local supplier e Easytrack can not be used with any type of suspended ceiling including suspended drywall acoustic tile etc e Installation on a plaster ceiling may cause cracking Sunrise Medical cannot be held responsible for damage Do not install on a ceiling with water damage Do not over tighten ceiling plate as this may cause ceiling to crack If flooring is not according to local building code standards flooring may be damaged Do no
9. lacement Lifter including hydraulics 1 year Accessories on Lifter 1 year Slings 1 year Batteries 3 months Easytrack System 1 year For warranty service please contact the provider from whom you purchased the Sunrise Medical product In the event that you do not receive satisfactory warranty service please contact Sunrise Medical customer service at 1 800 333 4000 Do not return products to our factory without prior authorization Sunrise Medical will issue a Return Merchandise Authorization RMA Number C 0 D shipments will be refused all shipments to Sunrise Medical must be prepaid For this warranty to be valid the purchaser must present its original proof of purchase at the moment of the claim The defective unit assembly or part must be returned to Sunrise Medical for inspection The part or compo nents repaired or replaced are guaranteed for the remaining period of the initial warranty Limitations and Exclusions The above warranty does not apply to serial numbered products if the serial number has been removed or defaced No warranty claim shall apply where the product or any other part thereof has been altered varied modified or damaged either accidentally or through improper or negligent use and storage Warranty does not apply to products modified without Sunrise Medical s express written consent including but not limited to products modified with unauthorized parts or attachments products damaged by reason of repair
10. late This will not lower the post The post must turn to enable you to attach the rail 18 Place the rail onto the pins of the bath post Figure 15 Refer to the drawing to find out which set of pins to use to hang the rail a For the 2 post assembly use the higher set of pins Figure 16 b For 3 post assembly with the bath bracket installed on pivot ing rail use the lower set of pins Figure 17 19 Place one round blue cap on the top of the post Figure 18 20 Slide the blue plastic strips into the slides of the posts by pinching the strip on each side to press it into the grooves Start at the bottom of the posts Figure 19 Figure 16 Figure 17 Figure 18 Figure 19 Bath Base Kit Specifications Maintenance BATH BRACKET SPECIFICATIONS 67 90 5 1700 2300 mm MAINTENANCE AWARNING Maintenance must be performed only by qualified personnel AWARNING Failure to follow maintenance instructions below when indicated could result in injury or damage AWARNING Periodic inspection should be performed by a person who is suitably and properly qualified and well acquainted with the design use and care of the Easytrack System Inspection should be carried out both routinely at least as often as specified and as necessary All defects and damages that have lead to corrective actions should be noted signed and dated by the inspector Defects and resulting a
11. or dust and must be dry before placing the tub base onto the tub DO NOT ATTEMPT TO INSTALL THE BATH BASE WITHOUT THOROUGHLY CLEANING AND DRYING THE SURFACE OF THE TUB Floor beneath the tub must be according to local building code standards Water damage or termites may affects the integrity of the floor or wall structure If you have any doubt with respect to the ceiling or bath structure consider installing the Easytrack System with a wall mount The wall mount must be installed by a licensed contractor AWARNING Ensure posts are straight using the level provided failure to do so may cause injury Every month a maintenance check should be done to ensure all posts are level See Maintenance section in this manual Make sure the padded surface of the top plate and foot plate are kept clean and are intact Protect the Easytrack System and its accessories during transport Bath Base Kit Assembly of Bath Base Kit EASYTRACK BATH BASE KIT KIT CONTENTS amp PART NUMBERS FIGURE 1 Description Part Oty 1 Bath base rail N A 1 2 Bath post N A 1 3 Blue locking handle N A 1 4 Round blue cap 900 0720 1 5 Allen key 6mm 900 3280 1 6 Top plate 900 0400 1 7 Flat blue cap 900 1050 1 8 Blue plastic strips 2 post 900 0230 2 9 Blue bath base cover N A 1 ASSEMBLY OF BATH BASE KIT Tools Reguired e Step ladder e Tape measure e Scissors or knife e An assistant gt feet 2 Using 6mm Allen key loosen the Take
12. rail by sgueezing the sides of the sides of the strip into the edges of the rail Figure 6 NOTE The plastic post base only slides on one end of the bath base It may be neces sary to turn the bath base rail around to place the plastic post base in the proper position 9 Take the bath post and the top plate out of the box 10 Place the top plate into the top of the post press firmly and evenly downward until the top plate clicks into place Figure 7 11 Place the clip on level on the post at about waist height Figure 8 12 Take the bath post and press it down onto the plastic post base Pay attention to the shape of the post and post base before pressing down onto the post base 13 Extend the post guickly towards the ceiling by pulling the top portion and holding the bottom portion The post should be within 3 76 mm to touching the ceiling If the top of the post is more than 3 76 mm from the ceiling a Raise the top portion of the post slightly Figure 9 b Pressin metal pin on both sides of the post Figure 10 NOTE Metal pins cannot be pressed in when there is downward pressure on them Pressure must be released to press in pin Click Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 c Pull top portion of post up towards the ceiling d Repeat until the top of the post is less than 3 76 mm from the ceiling 14 Lift the blue locking handle out of the lower po
13. rtion of the post Using the blue piece as a handle twist the post as follows Figure 11 a Turn top portion counterclockwise b Hold bottom portion firmly 15 Before the Easytrack post tightens against the ceiling check the clip Figure 12 on level to make sure the bubble is in the center of the circle Tilt the post until the bubble reaches the center of the circle Figure 12 Bath Base Kit Assembly of Bath Base Kit 7 AWARNING Make sure clip on level is fully attached to the post Failure to attach level properly could give an incorrect reading Level should ase click into place 16 Once the bubble is in the center of the clip on level continue to tighten ONLY until the red zone at the top of the post is no longer visible Figures 13 A amp B AWARNING Red zone must not be visible for the post to be safely secure AWARNING Do not over tighten the post Tighten only until red zone disap pears Overtightening of the post may cause damage to ceiling Figure 13 A Figure 13 B 17 Remove the level from the post by sliding it up off the bottom portion E n of the post Slide the blue locking Figure 14 Figure D handle down to fit into the bottom part of the post to lock the post in place Figure 14 NOTE Once the blue locking handle is pressed into the bottom portion of the post the post can be turned as a whole except the top and foot p
14. s made to any component without the specific consent of Sunrise Medical or to products damaged by circumstances beyond Sunrise Medical s control Evaluation of warranty claim will be solely determined by Sunrise Medical The warranty does not apply to problems arising from normal wear or failure to adhere to the instructions in this manual Sunrise Medical Inc slings are void of warranty if not laundered as per instructions on the Sling Label Sunrise Medical Inc shall not be liable for damages losses or inconveniences caused by a carrier This warranty replaces any other warranty expressed or implicit and constitutes Sunrise Medical Inc s only obligation towards the purchaser Sunrise Medical shall not be liable for any consequential or incidental damages whatsoever Bath Base Kit SUNRISE MEDICAL www sunrisemedicalonline com Distributed by Sunrise Medical 7477 East Dry Creek Parkway Longmont Colorado 80503 800 333 4000 In Canada 800 263 3390 Printed in Canada 2001 Sunrise Medical 10 01 900 0660 Rev A
15. t install on a sloped floor Do not drop product may cause breakage Do not completely submerge in water Do not attempt to over extend the rail past the locking point Do not install product if neoprene on top or bottom plate appears to be damaged or absent When the Easytrack is in Use AWARNING Do not hit posts this might cause unit to become unstable If posts are hit reassemble Easytrack System to ensure the posts are straight e If you use a power wheel chair use extreme care Hitting posts may cause unit to become unstable If posts are hit reinstall the Easytrack System to ensure the posts are straight Do not lean against posts Do not use the Easytrack System as a swing e Refrain from swinging user sideways of rail Bath Base Kit Reguirements REOUIREMENTS Ceiling Reguirements AWARNING Failure to meet reguirements listed below could result in serious bodily harm Install to a rigid ceiling must have a framework above it en j T h Must have a maximum of 24 610mm Joists i Joists between the trusses in the ceiling T N s E I Suspended Ceiling must be made of wood or amp I mre Or pode 1 2 12 7mm sheet rock or thicker I Fe Ensure ceiling and floor are clear of S Sheet rock T Sheet rock any dust grease water or any foreign or tile substance AWARNING A build up of nicotine grease or water on the ceiling will affect the integrity of the Easytr