Home
Sun Microsystems FIRE V20Z User's Manual
Contents
1. Subcommand Description access add trust Creates a host based trust relationship for the specified host access delete trust Removes a host based trust relationship for the specified host access get trusts Requests a list of hosts involved in trust relationships with the SP Access Add Trust Subcommand Description Creates a host based trust relationship for the specified host Adding host based trusts provides many to one scripting solutions Once a host equivalence relationship has been created with a client users on that client can remotely execute commands on the SP without being prompted for a password provided one of the following conditions is met m their login on the client has the same user name as a local user on the SP m their login on the client is in a directory service group that is mapped to an SP administrative group Format Command format access add trust c client HOST k keyfile PUBLIC KEY FILE TABLE B 20 lists the arguments for this subcommand TABLE B 20 Arguments for Subcommand access add trust Arguments Description c client Specifies the host for which to create the relationship k keyfile Specifies the public key file Appendix B Access Commands 91 If the login is authorized through a mapping of a directory service group the ssh command is executed as the proxy user on the SP either rmonitor radmin or rmanager Support is available for SSH protocol ve
2. Proxy Agent The SP acts as an SNMP proxy agent intermediary for the platform Queries made from a management station to the SNMP agent on the SP are intercepted by the proxy agent on the SP and forwarded to the platform the SP proxy agent contacts the platform to retrieve the requested information The proxy agent then receives the data from the platform and sends the request back to the management station The management station never knows that the request was proxied The SP and the platform communicate over an internal private network To enable this facility you must first run an SNMP agent on your platform operating system see your operating system vendor to obtain this agent This enables platform level management transparently through the SP Querying MIBs other than the server MIB for example the Host Resource MIB and the MIBII System MIB on the SP obtains information from the platform by proxying the request to the platform SNMP agent Ensure that the SP can identify the read only and read write community names that are configured for your platform SNMP agent Refer to Setting the Community Name on page 46 Chapter 3 SNMP Server Management 45 Setting the Community Name The SNMP agent on the SP acts as a proxy for the SNMP agent running on the platform Refer to Configuring SNMP on Your Server on page 44 To properly proxy you must use the community string The community string needed to do so is the val
3. SP MasterAgent MIB mib SP INVENTORY MIB mib SP SST MIB mib SP PLATFORM MIB mib SP EVENT MIB mib SP GROUP MIB mib 1 3 6 1 4 1 9237 1 3 6 1 4 1 9237 2 1 1 1 1 3 6 1 4 1 9237 2 1 1 1 2 1 3 6 1 4 1 9237 2 1 1 1 3 1 3 6 1 4 1 9237 2 1 1 4 1 3 6 1 4 1 9237 2 1 1 5 1 3 6 1 4 1 9237 2 1 1 6 1 3 6 1 4 1 9237 2 1 1 7 Creates the main trunk of the server MIB tree All other MIBs of the SP branch from this tree To be loaded first while integrating with any third party framework Used for querying inventory information for all Sun Fire V20z and Sun Fire V40z servers hardware and software components Hardware Inventory Table Collects all hardware component inventory Software Inventory Table Collects all software component inventory Defines objects for the System State Table in the SP Contains all sensor readings including the name of the sensor its current value maximum allowed value measurement type scale and scanning interval Defines objects for the platform SNMP which includes osstate platform state and platform IP table Identifies the OIDs associated with all SNMP traps originated from the SP Defines objects for the SP including host name DNS a reboot node a node to hold the last port 80 postcode a clone tree and an IP table Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 The events listed in TABLE 3
4. TABLE H 62 Arguments for Subcommand sp get mount Arguments Description 1 local Specifies the local mount point If you do not specify 1 mnt is implicit as the local mount point H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE H 63 lists the return codes for this subcommand TABLE H 63 Return Codes for Subcommand sp get mount Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NotFound 5 Entity user service file path or other not found NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused 204 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 63 Return Codes for Subcommand sp get mount Return Code ID Description NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down NWSE_NotMounted 21 File system is not mounted SP SMTP Subcommands The subcommands in TABLE H 64 manage SMTP communications TABLE H 64 SP SMTP Subcommands Subcomma
5. The following software components are included with the server Platform BIOS SP base software SP value add software Update file for downloading Java Runtime Environment JRE packages Network share volume software which includes diagnostics Platform software Motherboard platform drivers All of these software packages are packaged with the NSV and are installed on the file server when the external file system is installed and configured For instructions on extracting and installing the NSV software refer to the Sun Fire V20z and Sun Fire V40z Servers Installation Guide Network Share Volume Structure The following compressed packages are included with your server on the Sun Fire V20z and Sun Fire V40z Servers Network Share Volume CD TABLE 4 1 Network Share Volume Compressed Packages File Name File Contents nsv_V2 1 0 x zip Service processor software nsv redhat_V2 1 0 x zip Drivers for Red Hat Linux OS nsv solaris9_V2 1 0 x zip Drivers for Solaris 9 OS nsv suse_V2 1 0 x zip Drivers for SUSE Linux OS 68 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 When extracted the compressed packages in TABLE 4 1 populate the following files on the NSV mnt nsv diags logs scripts snmp spupdate sw_images this folder appears after you extract one of the OS specific Zip files TABLE 4 2 Extracted Files on the Network Share Volume File Name Description diags Offline location
6. Enabling IPMI Access on a Solaris Based x86 Server In Band 1 Log in to the server and authenticate as the user root 2 Run the following command to install the LIPMI Solaris x86 kernel driver and the IPMItool management control application These files are located on the Documentation and Support Files CD in the support sysmgmt solaris9 directory pkgadd d Confirm installation of all packages when prompted 3 Reboot the server 16 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Enabling IPMI LAN Access This section contains three alternate procedures two in band procedures and one out of band procedure Use the procedure that corresponds to your OS a Enabling IPMI LAN Access on a Linux Based Server In Band on page 17 a Enabling IPMI LAN Access on a Solaris Based x86 Server In Band on page 18 a Alternate Method for Enabling IPMI LAN Access Out of Band on page 18 Enabling IPMI LAN Access on a Linux Based Server In Band If the server is powered off boot the local OS Log in to the server and authenticate as the user root Load the OpenIPMI kernel device driver as installed in Part III Step 3 modprobe ipmi_kcs_drv Using IPMItool configure the network setting for the SP Note For more information on the syntax for IPMItool commands refer to Syntax on page 30 ipmitool I open lan set ipmitool I open lan set ipmitool I
7. When prompted press lt F2 gt to enter BIOS setup Select the Advanced menu from the category selections along the top Select Console Redirection Note Make note of all settings in this menu as they are required for configuring the remote console access and the Serial Over LAN SOL feature Select I O Device Configuration Select On board COM A from the Port option to enable console redirection to serial Ensure that COM A is enabled on I O port 3F8 FRQ4 m To change the baud rate you can select the desired bit rate from the Baud Rate option m To disable console redirection to serial you can select Disabled from the Port option Save the changes to the BIOS settings Press lt F10 gt to exit the BIOS setup For the new settings to take effect you must reboot the server Chapter 4 Further Management Information 67 Network Share Volume NSV CD ROM A network share volume NSV structure is included with the server on the Sun Fire V20z and Sun Fire V40z Servers Network Share Volume CD Although the SP functions normally without access to an external file system a file system is required to enable several features including event log files software updates diagnostics and the troubleshooting dump utility You can configure the NSV to be shared among multiple SPs Admin and manager level users can configure the external file system regular users can only view the current configuration
8. Command format platform console You must configure the BIOS settings using the BIOS Setup utility To refresh the BIOS Setup screen press Control R Choose the Advanced tab to set the configuration 134 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE F 3 lists common COM1 values TABLE F 4 lists common values for console redirection TABLE F 3 Common COMI Values VO Device Configuration Serial port A Enabled Base I O address 3F8 Interrupt IRQ 4 TABLE F 4 Common Values for Console Redirection Console Redirection Com Port Address On board COM A Console connection Direct Baud Rate 19 2K Flow Control None Console Type ANSI Note You can change these values as long as they are the same as serial port values for the operating system OS If your operating system supports the COM2 4 values you can set these for the BIOS settings The serial console settings in the platform OS should be set to match the BIOS settings Enter the following while you are connected to the console Ec character where E represents Control E and character is one of the entries in TABLE F 5 TABLE F 5 Serial Console Values Character Function Disconnects an attach read write b Sends a broadcast message c Toggles flow control d Takes down a console e Changes the escape sequence Appendix F Platform Commands 135 TABLE F 5 Serial Console Values Char
9. D delim Specifies to delimit columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE B 37 lists the return codes for this subcommand TABLE B 37 Return Codes for Subcommand access get users Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage He Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid Appendix B Access Commands 103 Access Update Password Subcommand Note This command is for managers to change other users passwords all users can change their own passwords Description Changes the password of an existing user Format Command format access update password p password PASSWORD u user USER TABLE B 38 lists the arguments for this subcommand TABLE B 38 Arguments for Subcommand access update password Argument Description u user The name of the user whose password you wish to update If a username is not specified the current user is implied You must have manager level access to change another user s password
10. Format Command format access unmap a all DIRECTORY SERVICES GROUP TABLE B 10 lists the arguments for this subcommand TABLE B 10 Arguments for Subcommand access unmap Argument Description DIRECTORY SERVICES GROUP a a11 The name of the directory services group for which you wish to remove a mapping Removes mappings for all of the directory services groups 84 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 11 lists the return codes for this subcommand TABLE B 11 Return Codes for Subcommand access unmap Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage t Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation Appendix B Access Commands 85 86 Access Directory Services Subcommands Services defines a directory services mechanism that determines the group memberships for a user Remote users gain access to the Service Processor features only through these group mappings that relate a directory services group to
11. User Level Auth enabled Access Mode always available userinfo channel Note Channels 6 and 7 are not supported on Sun Fire V20z servers Displays information about configured user information on a specific LAN channel EXAMPLE ipmitool I open userinfo 6 Maximum User IDs 4 Enabled User IDs tro lt Fixed Name User IDs 1 Access Available call in callback Link Authentication disabled IPMI Messaging enabled chassis status identify interval restart_cause Returns information about the high level status of the server chassis and main power subsystem Controls the front panel identification light The default value is 15 seconds Enter 0 to turn it off Queries the chassis for the cause of the last server restart Chapter 2 IPMI Server Management 33 TABLE 2 2 Expressions and Parameters for IPMItool 3 of 4 Expression Parameter Sub parameter Description and examples power status on off cycle reset lan print set channel channel parameter ipaddr x x x x netmask x x x x macaddr XXEXX XX XX XX XX defgw ipaddr X X X X defgw macaddr XXEXXXXEXX XX XX bakgw ipaddr X X X X bakgw macaddr XXEXXXX XX XX XX password pass user access on off ipsrc source Performs a chassis control command to view and change the power state Shows the current status of the chassis power Powers on the chassis Powers off chass
12. Using a Third Party MIB Browser The following example demonstrates integrating the server MIBs into an SNMP node manager From the Manager Preferences menu choose Load Unload MIBS SNMP Locate and select the SP MasterAgent MIB mib Click Load Specify the directory in which the server MIBs are placed and click Open Repeat steps 2 through 4 to load other MIBS for example SP SST MIB mib SP INVENTORY MIB mib SP EVENT MIB mib SP PLATFORM MIB mib SP GROUP MIB mib and so on Exit the Manager Preferences menu Open an SNMP MIB browswer The SNMP standard tree displays in the MIB Browser Locate the Newisys branch located under private enterprises Refer to FIGURE 3 1 for a sample view of the MIB tree Setting Logging Options You can also easily integrate SP generated traps and set logging options The following example demonstrates the necessary steps when using HP OpenView NNM Load the SP EVENT MIB mib according to the previous procedure Choose Options gt EventConfiguration Select the spEvent module from the Enterprises list Double click an event from the Events for Enterprise spEvent list Select the Event Message tab Select the Log and display in category radio dialog and choose a category from the corresponding dropdown list or create your own event category Select the severity of the event from the Severity dropdown list Enter a message or to display all information in th
13. warnhigh w warnlow N name d description S sensor type p parent comp s severity verbose I noid H noheader D delim lt DELIMITER gt 154 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE G 2 lists the arguments for this subcommand TABLE G 2 Arguments for Subcommand sensor get Arguments i id t type v value n nominal c crithigh e critlow W warnhigh w warnlow N name d description S sensor type p parent comp s severity verbose Description SENSOR_ID PRODUCT ID BOARD REVISION PRS REVISION Specifies the sensor for which the data is desired You can specify this argument multiple times in which case the sensor data is reported in the order specified You can also retrieve the product ID board revision number and PRS revision number using this flag Specify vIH following the ID to convert the output to the appropriate product ID For example product ID 255 indicates the 2100 server and product ID 239 indicates the 4300 server You can also obtain this information using the inventory get hardware command Specifies the sensor class for which the data is desired You can specify this argument multiple times in which case the sensor output is grouped by type in the order specified Current sensor classes
14. C Makes the output suitable for parsing where possible by separating fields with commas instead of spaces 8 Attempts to make IPMI over LAN communications more robust V Displays the version information v Increases the amount of text output This option may be specified I interface H address P password more than once to increase the level of debug output If given three times you receive hexdumps of all incoming and outgoing packets Selects the IPMI interface to use The possible interfaces are LAN or open interface Displays the address of the remote server it can be an IP address or host name This option is required for the LAN interface connection Displays the password for the remote server the password is limited to a maximum of 16 characters The password is optional for the LAN interface if a password is not provided the session is not authenticated Chapter 2 IPMI Server Management 31 Expressions TABLE 2 2 lists the expressions and parameters available for IPMItool Note For each of these expressions the beginning command is always ipmitool followed by the expression and parameter s Note The sol command is not supported in these servers but you can enable a Serial over LAN feature See Serial Over LAN on page 70 TABLE 2 2 Expressions and Parameters for IPMItool 1 of 4 Expression Parameter Sub parameter Description and examples help Can be used to get
15. Date Subcommands 162 SP Get Date Subcommand 162 Format 162 Return Codes 163 SP Set Date Subcommand 163 Format 163 Return Codes 164 SP DNS Subcommands 165 SP Disable DNS Subcommand 165 Return Codes 165 SP Enable DNS Subcommand 166 Format 166 Return Codes 166 SP Get DNS Subcommand 167 Format 167 Return Codes 167 SP Events Subcommands 168 SP Delete Event Subcommand 168 Format 168 Return Codes 169 SP Get Events Subcommand 169 Format 169 Return Codes 170 SP Hostname Subcommands 171 SP Get Hostname Subcommand 171 Format 171 Return Codes 172 SP Set Hostname Subcommand 172 Contents xiii Format 172 Return Codes 173 SP IP Subcommands 174 SP Get IP Subcommand 174 Format 174 Return Codes 175 SP Set IP Subcommand 175 Format 175 Return Codes 176 SP JNET Address Subcommands 177 SP Get JNET Subcommand 177 Format 177 Return Codes 178 SP Set JNET Subcommand 178 Format 178 Return Codes 179 SP Locate Light Subcommands 180 SP Get Locatelight Subcommand 180 Format 180 Return Codes 180 SP Set Locatelight Subcommand 181 Format 181 Return Codes 181 SP Logfile Subcommands 182 SP Get Logfile Subcommand 182 Format 182 Return Codes 183 SP Set Logfile Subcommand 183 xiv Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Format 183 Return Codes 184 SP Miscellaneous Subcommands SP Create Test Events Subcommand Format 185 Return Codes 186 SP Get Port 80 Subcommand Format 186 Return Codes 187 BIO
16. Entity user service file path etc was not found 80 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Access Get Groups Subcommand Description Returns a list of the groups defined including the standard groups Format Command format access get groups Return Codes TABLE B 4 lists the return codes for this subcommand TABLE B 4 Return Codes for Subcommand access get groups Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server Appendix B Access Commands 81 Access Map Subcommands The subcommands in TABLE B 5 manage mappings between existing site specified groups and one of the standard administrative groups TABLEB 5 Access Map Subcommands Subcommand Description access get map Returns the names of all the site specified groups mapped to a specific administrative group access map Maps an existing site specified group name the directory service group to one of the standard administrative groups access unmap Removes the directory service group and administrative group mapping Access Get Map Subcommand Description Returns
17. H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string 174 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 24 lists the arguments for this subcommand TABLE H 24 Return Codes for Subcommand sp get ip Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down SP Set IP Subcommand Description Sets or modifies the SP network configuration Format Command format sp set ip dhcp nowait sp set ip static i ipaddress IP ADDRESS n netmask NETMASK g gateway GATEWAY w nowait Appendix H Service Processor Commands 175 TABLE H 25 lists the arguments for this subcommand TABLE H 25 Arguments for Subcommand sp set ip Argument i ipaddress n netmask g gateway w nowait Description Specifies the IP address you wish to set Specifies the netmask the default value is 255 255 255 0 Spec
18. IPMI Compliance and LAN Channel Access The server supports IPMI through the SP software version 2 0 and later These servers meet compliance standards for IPMI version 1 5 The IPMI implementation on these servers also support LAN channel access Refer to the IPMI specification version 1 5 for details The LAN channel access is disabled by default To enable it use the ipmi enable channel command and specify the ID of the channel to enable for the LAN Interface as follows Note This ID is case sensitive and must be lowercase ssh spipaddr 1 spuser ipmi enable channel sms lan For more information about enabling or disabling the IPMI channel refer to Appendix B Usernames and Passwords Operator and administrator level access over the LAN channel requires a valid user ID and password These servers come preconfigured with an administrator level user with a null user ID However you can re add the anonymous user at a later time if you wish You can configure both the user ID and password to be null Note For security reasons the LAN channel access is disabled by default Note IPMI user identities are in no way associated with user accounts defined for server management capabilities Refer to Initial Setup of the Service Processor on page 9 for more information about these server management user accounts Chapter 2 IPMI Server Management 29 Lights Out Management LOM On these servers Ligh
19. NWSE_InvalidUsage t Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation NWSE_FileError 18 FileFile open file missing or a read or write error occurred NWSE_Exist 19 Entity user service or other already exists Access Delete Trust Subcommand Description Removes a host based trust relationship for the specified host Format Command format access delete trust CLIENT HOSTNAME a all q quiet TABLE B 22 lists the arguments for this subcommand TABLE B 22 Arguments for Subcommand access delete trust Argument Description CLIENT HOSTNAMI pg Specifies the name of the client to remove a all Removes all trust relationships q quiet If the trust relationship to delete is not found this argument specifies that no error be returned Appendix B Access Commands 93 Return Codes TABLE B 23 lists the return codes for this subcommand TABLE B 23 Return Codes for Subcommand access delete trust Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 R
20. Refer to the following appendices in this user guide for each subcommand and the corresponding return codes for that subcommand TABLE A 2 Return Codes 1 of 2 Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were NWSE_NotFound incorrect or invalid 5 Entity user service file path etc was not found 76 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE A 2 Return Codes 2 of 2 Return Code ID Description NWSE_NoPermission 6 Not authorized to perform this operation NWSE_MissingArgument 7 Missing argument s NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_NotImplemented 10 Function not implemented NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down NWSE_UnknownError 15 Miscellaneous error not captured by other errors NWSE_GatewayOffNet 16 Gateway address is not on network NWSE_NetMaskIncorrect 17 An inappropriate netmask was speci
21. SP menu Menu SP menu Press the Select operator panel button to display the SP menu options SP Menu Set SP IP info Press the Select operator panel button The following prompt displays with the default response SP use DHCP No Press the Select operator panel button The LCD displays as follows SP IP Address 0 0 0 0 With the cursor in the first field increase or decrease the value using the Back and Forward operator panel buttons This field can hold a value between 0 and 255 SP IP Address 10 0 0 0 After reaching your desired value press the Select operator panel button to advance the cursor to the next field SP IP Address 10 0 0 0 Chapter 1 Introduction 11 Note The Back and Forward operator panel buttons automatically scroll repeating the action as long as the button is held down 8 Repeat Step 6 and Step 7 for each field until the desired IP address is displayed then use the Enter button combination to save the IP Address The process continues to the next network setting the Subnet Mask The LCD displays as follows SP netmask 255 255 255 0 9 Edit the subnet mask setting in the same manner as you did for the IP address When finished use the Enter button combination to save the subnet mask The process continues to the next network setting the default gateway The LCD displays as follows SP IP Gateway 10 10 30 1 10 Edit the default gateway setting in the same ma
22. SP remains in the Communicating state even though it can no longer communicate with the platform Refer to Platform Get OS State Subcommand on page 142 for a list of possible states Return Codes TABLE F 15 lists the return codes for this subcommand TABLE F 15 Return Codes for Subcommand platform set os state Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation NWSE_Busy 9 Device or resource is busy NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_InvalidOpForState 22 Invalid operation for current state Platform Set OS State Boot Subcommand Description This command serves as an alias for the subcommand platform set os state reboot and only functions when the platform power state is off Format Command format platform set os state boot f forced b bios q quiet W nowait Appendix F Platform Commands 145 TABLE F 16 lists the arguments for this subcommand TABLE F 16 Arguments for Subcommand platform set os state boot Arguments Descriptio
23. Subcommand Description sp get jnet Retrieves the JNET address sp set jnet Sets the JNET address SP Get JNET Subcommand Description Retrieves the IP address of the platform JNET driver Format Command format sp get jnet H noheader D delim lt DELIMITER gt TABLE H 28 lists the arguments for this subcommand TABLE H 28 Arguments for Subcommand sp get jnet Argument Description H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Appendix H Service Processor Commands 177 Return Codes TABLE H 29 lists the return codes for this subcommand TABLE H 29 Return Codes for Subcommand sp get jnet Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_HostDown 14 Host is down SP Set JNET Subcommand Description Sets or modifies the SP and platform network addresses for JNET Because of the firewall between these drivers you must specify both addresses at the same time Both the SP and Platform JNET addresses must be on the same Class C subnet Format Command format sp set jnet p platform IP ADDRESS s sp IP ADDRESS
24. This argument is repeatable to update multiple user s passwords at one time p password The user s new password If a password is not specified a prompt appears to enter the password and again to confirm the password Return Codes TABLE B 39 lists the return codes for this subcommand TABLE B 39 Return Codes for Subcommand access update password Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage ae Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server 104 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE B 39 Return Codes for Subcommand access update password Return Code ID Description NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation Access Update User Subcommand Description Updates the login information password or group for the user Format Command format access update user u user USER p password PASSWORD g group GROUP TABLE B 40 lists the arguments for this subcommand Note The p and
25. V40z service processor using settings on a Sun Fire V20z service processor To perform autoconfiguration of an SP follow these steps You can start autoconfiguration either when you are prompted at the completion of setting the IP address of the SP or by selecting Autoconfigure from the SP menu option on the operator panel at any time 1 On the operator panel press the Forward or Back buttons until the following prompt shows Yes SP Auto Setup No For instructions on setting an IP address refer to the Sun Fire V20z and Sun Fire V40z Server Installation Guide 2 Press the Select button The SP attempts to locate an IP address m If the SP successfully locates an IP address the following prompt appears displaying an IP address for this SP Setup Server IP XK eL Where x x x is the first three octets of the SP IP address For example if the address is 10 10 30 19 the address that displays in the prompt appears as 10 10 30 1 In this case press the Select operator panel button to start autoconfiguration 24 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 m If the SP does not locate an IP address the following message appears Unable to get SP IP address In this case you must manually enter an IP address before you press the Select operator panel button to start autoconfiguration 3 Wait until the autoconfiguration is complete at which point the SP automatically reboots The fo
26. a local Service Processor administrative group Therefore using the command access map the administrator must set up the appropriate directory services configuration and create mappings from the directory services groups to local Service Processor administrative groups TABLE B 12 lists the Access Directory Services subcommands TABLE B 12 Access Directory Services Subcommands Subcommand Description access disable service Disables a directory service access enable service Enables a directory service access get services Defines a directory services mechanism that determines the group memberships for a user Access Disable Service Subcommand Description Disables a directory service either NIS or ADS from the name service lookup system on the SP Format Command format access disable service nis ads TABLE B 13 lists the argument for this subcommand TABLE B 13 Argument for Subcommand access disable service Argument Description nis ads Specifies the service type NIS or ADS Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 14 lists the return codes for this subcommand TABLE B 14 Return Codes for Subcommand access disable service Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was iss
27. are voltage fan temperature current power and switch Displays the current value of the sensor Displays the nominal value of the sensor Displays the critical high threshold value for the sensor Thresholds configured to a value other than the factory value display with a trailing asterisk character Displays the critical low threshold value for the sensor Displays the warning high threshold value for the sensor Displays the warning low threshold value for the sensor Displays the name of the sensor Displays a description of the sensor Displays the type of sensor for use with type Displays the parent component list for the sensor These are the components that are affected by changes in the value of a sensor for example the components that change severity as the sensor changes severity Displays the current severity lever of the sensor nominal warning or critical Displays all columns you cannot use this argument with any of the other column addition options Appendix G Sensor Commands 155 TABLE G 2 Arguments for Subcommand sensor get Arguments Description I noid Suppresses the display of the sensor ID column By default this column always displays when more than one sensor is selected H noheader Suppresses the column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or stri
28. columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE D 7 lists the return codes for this subcommand TABLE D 7 Return Codes for Subcommand inventory get software Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server Appendix D Inventory Commands 121 Inventory Get All Subcommand Description Returns detailed information for all field replaceable hardware components and all installed or uninstalled software Format Command format inventory get all a all v verbose H noheader D delim lt DELIMITER gt TABLE D 8 lists the arguments for this subcommand TABLE D 8 Arguments for Subcommand inventory get all Arguments Description a all Optional Looks in the directory sw_images on the Service Processor for software packages and uninstalled software v verbose Displays all columns H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless supp
29. command line help on IPMItool commands It may also be placed at the end of commands to get help on the use of options EXAMPLES ipmitool I open help Commands chassis fru lan sdr sel ipmitool I open chassis help Chassis Commands status power identify policy restart_cause ipmitool I open chassis power help Chassis Power Commands status on off cycle reset diag soft raw netfn cmd data Allows you to execute raw IPMI commands for example to query the POH counter with a raw command EXAMPLE ipmitool I open raw 0x0 0x1 RAW REQ netfn 0x0 cmd 0x1 data_len 0 RAW RSP 3 bytes 60 00 00 32 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE 2 2 Expression Expressions and Parameters for IPMItool 2 of 4 Parameter Sub parameter Description and examples chaninfo channel Displays information about the selected channel If no channel is specified the command displays information about the channel currently being used EXAMPLES ipmitool I open chaninfo Channel Oxf info Channel Medium Type System Interface Channel Protocol Type KCS Session Support session less Active Session Count 0 Protocol Vendor ID 7154 ipmitool I open chaninfo 7 Channel 0x7 info Channel Medium Type 802 3 LAN Channel Protocol Type IPMB 1 0 Session Support multi session Active Session Count 1 Protocol Vendor ID 7154 Alerting enabled Per message Auth enabled
30. console tty0 After modifying the file etc lilo conf run lilo from the command line to activate the change For more information on LILO run the commands man lilo or man lilo conf Chapter 4 Further Management Information 65 66 getty You can run a service called getty to enable login on the serial interface To enable getty append the following line to the list of gettys in the etc inittab file 7 12345 respawn sbin agetty 9600 ttyS0O Note It does not matter where you append this line in the list Note Make certain that the first number is unique within the inittab file The list of gettys currently looks like the following Run gettys in standard runlevels 2345 respawn sbin mingetty ttyl 2345 respawn sbin mingetty tty2 2345 respawn sbin mingetty tty4 I 2 3 2345 respawn sbin mingetty tty3 4 5 2345 respawn sbin mingetty tty5 6 2345 respawn sbin mingetty tty6 securetty To add the serial console device dev ttyS0 to the file etc securetty run the following command echo ttyS0 gt gt etc securetty Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Enabling and Configuring BIOS Console Redirection Note Console redirection is enabled by default in the BIOS If the default settings have been changed in the BIOS the following procedure explains how to change the console redirection settings Boot or reboot the server
31. enable for the LAN Interface not case sensitive If you are activating the LAN channel for the first time you are prompted for a password to associate with the null user Return Codes TABLE E 5 lists the return codes for this subcommand TABLE E 5 Return Codes for Subcommand ipmi enable channel Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage L Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_ServiceNotAvailable 24 Requested service is not available Appendix E IPMI Commands 125 IPMI Get Channels Subcommand Description Displays the list of IPMI channels and whether they are enabled or disabled Format Command format ipmi get channels Return Codes TABLE E 6 lists the return codes for this subcommand TABLEE 6 Return Codes for Subcommand ipmi get channels Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified 126 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 IPMI Disable PEF Subcommand Description Allows you to disable platform event filtering PEF Format Command format ipmi disable pef Return Codes TABLE E 7 lists the return codes for t
32. exists Appendix H Service Processor Commands 213 SP Delete SNMP Destination Subcommand Description Deletes a single SNMP destination either IP address or host name Format Command format sp delete snmp destination IP_ADDRESS HOSTNAME a all q quiet TABLE H 78 lists the arguments for this subcommand TABLE H 78 Arguments for Subcommand sp delete snmp destination Arguments Description IP ADDRESS HOSTNAMI GJ Specifies the IP address or hostname of the destination to remove This argument is repeatable to remove multiple destinations at one time a all Removes all SNMP destinations q quiet If the SNMP destination to delete is not found this argument specifies that no error be returned Return Codes TABLE H 79 lists the return codes for this subcommand TABLEH 79 Return Codes for Subcommand sp delete snmp destination Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage L Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NotFound 5 Entity user service file path or other not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_
33. format access map d dsgroup DIRECTORY SERVICES GROUP g group LOCAL GROUP v verify TABLE B 8 lists the arguments for this subcommand TABLE B 8 Arguments for Subcommand access map Argument Description d dsgroup The name of the directory services group for which you wish to map to a standard administrative group g group The name of the standard administrative group to which you wish to map to the directory services group v verify Verifies the group existence Appendix B Access Commands 83 Return Codes TABLE B 9 lists the return codes for this subcommand TABLE B 9 Return Codes for Subcommand access map Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NotFound 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_InvalidOpForState 22 Invalid operation for current state Access Unmap Subcommand Description Removes the directory service group and administrative group mapping
34. open lan set ipmitool I open lan set ipaddr ipaddr netmask netmask defgw ipaddr gwipaddr password ipmipasswd e SE OE nn Chapter 1 Introduction 17 Enabling IPMI LAN Access on a Solaris Based x86 Server In Band 1 If the server is powered off boot the local OS 2 Log in to the server and authenticate as the user root 3 Using IPMItool configure the network setting for the SP by using the following commands Note For more information on the syntax for IPMItool commands refer to Syntax on page 30 ipmitool I lipmi lan set ipmitool I lipmi lan set ipmitool I lipmi lan set ipmitool I lipmi lan set ipaddr ipaddr netmask netmask defgw ipaddr gwipaddr password ipmipasswd OE nan Alternate Method for Enabling IPMI LAN Access Out of Band 1 Using an SSHv1 client or SSHv2 client log in to the IP address of the SP 2 Authenticate as the newly created management user see Part II Securing the Service Processor on page 13 ssh spipaddr 1 spuser 3 Enable IPMI LAN access and assign a password when prompted ipmi enable channel lan exit Note This password will be referred to as ipmipasswd in subsequent examples 4 Using IPMItool test the IPMI LAN access ipmitool I lan H spipaddr P ipmipasswd chassis status 18 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Upgrading the Linux Kernel Upgrading the installed
35. path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation Note There are some sensors whose value does not change some that are there to provide information in the event of a problem and others to facilitate the proper operation of the software Many of these sensors do not have a related component parent associated with them For example the die temperature sensor for a CPU has the CPU as its parent component and a fan speed sensor has the fan as its parent component the product id sensor however only reports a static value and has no parent relationship This relationship establishes the component s which is affected by changes in the value of the sensor You cannot modify the thresholds for sensors without a parent relationship since an event will never occur for these threshold crossings Appendix G Sensor Commands 159 160 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX H Service Processor Commands The sp command gets or sets the configuration values for the Service Processor SP generates or manages events and notices or adds or modifies subscribers event routes and email notification groups for the SP event manager TABLE H 1 lists the groups of sp subcommands Note Every command returns a return code upon completion TABLE H 1 Service Processor Subcommand Groups Subcommand Description Date Sets or retrieves
36. request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation Appendix B Access Commands 99 Access User Subcommands The subcommands listed in TABLE B 31 allow you to manage a single user or group of users TABLE B 31 Access User Subcommands Subcommand Description access add user Adds the specified local user to the specified group access delete user Deletes the specified user access get users Retrieves all the users in an administrative group or all users in all groups access update password Updates the password of the specified user access update user Updates the login information for the specified user Access Add User Subcommand Description Adds the specified local user to the specified group with the specified user ID and password Format Command format access add user p password PASSWORD g group GROUP u user USERNAME TABLE B 32 lists the arguments for this subcommand TABLE B 32 Arguments for Subcommand access add user Arguments Description p password Specifies the password for the new user The password is optional and if not specified a prompt displays requesting confirmation g group Specifies the group to which the new user will belong u use
37. securetty using 66 creating initial manager account 13 D daisy chain server configuration 20 diagram of server interconnections 20 227 diagram of server management options 5 diags commands cancel tests 108 get state 110 get tests 111 run tests 112 start 114 subcommands summary table 107 terminate 116 documentation related xx E enabling IPMI access 14 enabling IPMI LAN access 17 F flash ROM boot block codes 192 G getty using for console redirection 66 grub using for console redirection 64 H host key pairs for scripting 59 host keys scripting 57 l initial manager account creating 13 integration of SNMP protocol 42 intelligent platform management interface see IPMI interface interconnecting servers diagram 20 interfaces supported list 3 inventory commands compare versions 118 get all 122 get hardware 119 get software 121 subcommand summary table 117 IP address DHCP setting 9 IP address static setting 11 IPMI access enabling 14 in band enabling on Linux server 14 in band enabling on Solaris x86 server 16 upgrading the kernel 19 ipmi commands disable channel 124 disable pef 127 enable channel 125 enable pef 128 get channels 126 get global enables 129 reset 132 set global enable 130 subcommand summary table 123 IPMI interface baseboard management controller 28 compliance 29 IPMItool 30 LAN channel access 29 LAN interface for the BMC 36 lights out management 30 Linux kernel devic
38. service file path etc was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_InvalidOpForState 22 Invalid operation for current state SP Get Events Subcommand Description Returns detailed information about all active SP events By default event ID last update component severity and a message are displayed Administrators can view detailed information about all the currently active system events and perform various actions related to each event You can view this information in the System Events table which contains a row for each unique active system event or using this command For a list of all possible events refer to the TABLE 3 4 in Chapter 3 Format Command format sp get events i id lt EVENT ID gt d detail v verbose H noheader D delim lt DELIMITER gt Appendix H Service Processor Commands 169 TABLE H 15 lists the arguments for this subcommand TABLE H 15 Arguments for Subcommand sp get events Argument i id d detail v verbose H noheader D delim Return Codes Description Specifies to display only information about this event otherwise information for all existing events returns Specifies to display the history of either one or all events Specifies to display all columns Suppresses column headings Specifies to delimit columns wit
39. shutting down When the platform is in the Communicating state in which the OS is communicating with the SP if the platform drivers are uninstalled the SP remains in the Communicating state even though it can no longer communicate with the platform Refer to Platform Set OS State Subcommand on page 144 for more information about setting the state Return Codes TABLE F 13 lists the return codes for this subcommand TABLE F 13 Return codes for Subcommand platform get os state Return Code NWSE_Success NWSE_InvalidUsage NWSE_RPCTimeout NWSE_RPCNotConnected NWSE_NoPermission ID 0 Description Command successfully completed Invalid usage bad parameter usage conflicting options specified Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server Unable to connect to the RPC server Not authorized to perform this operation Appendix F Platform Commands 143 Platform Set OS State Subcommand Description Provides the ability to reboot the platform into the default OS BIOS setup or BIOS update or to shut down the platform Rebooting to BIOS setup allows you to configure the BIOS parameters while BIOS update allows you to reflash the BIOS image Format Command format platform set os state reboot W nowait b bios forced q quiet platform set os state reboot to diag
40. those listed in a release manifest Returns detailed information for all field replaceable hardware components Returns inventory information for all installed or uninstalled software Returns detailed information for all hardware and software components Note Every command returns a return code upon completion Inventory Compare Versions Subcommand Description Returns a list of all installed software packages and the version differences with those listed in a release manifest You can use this command to verify that your installation is consistent with a supported release and to determine the packages that have been updated in a new release Format Command format inventory compare versions f file RELEASE MANIFEST FILE v verbose TABLE D 2 lists the arguments for this subcommand TABLE D 2 Arguments for Subcommand inventory compare versions Arguments Description file The file describing all of the packages and versions within a release of software These files are at the root directory of an unzipped NSV file and are usually accessed via the share point at mnt v verbose Displays additional information including the path to the matching package on the NSV the installed package description and the matching manifest package description 118 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE D 3 l
41. troubleshooting 53 sp commands add mount 201 add snmp destination 212 create test events 185 date subcommands summary 162 delete event 168 delete mount 203 delete snmp destination 214 disable dns 165 disable ssl required 218 dns subcommands summary 165 enable dns 166 enable ssl required 219 get date 162 get dns 167 get events 169 get smtp subscribers 208 get snmp proxy community 216 get snmp destinations 215 get ssl 220 get status 194 get tdulog 195 hostname subcommand summary table 171 ip subcommands summary 174 JNET address subcommand summary 177 load settings 193 locatelight subcommand summary 180 logfile subcommand summary 182 miscellaneous subcommand summary 185 mount subcommands summary 201 reboot 197 reset 198 set date 163 set hostname 172 set ip 175 set jnet 178 set locatelight 181 set logfile 183 set smtp server 207 set snmp proxy community 216 set ss 221 smtp subcommands summary 205 snmp subcommands summary 212 SP events subcommand summary 168 ssl subcommands summary 218 subcommand group summary table 161 update diags 226 update flash all 222 update flash applications 224 update flash pic 225 update smtp subscriber 209 update subcommands summary 222 SSH access using public keys enabling for scripting 60 SSH access using trusted hosts enabling for scripting 59 230 get hostname 171 get ip 174 get jnet 177 get locatelight 180 get logfile 182 get mount 204 get
42. 0 lists the arguments for this subcommand TABLE H 60 Arguments for Subcommand sp delete mount Argument Description LOCAL MOUNT POINT Specifies the mount point to remove If you do not specify the local mount point mnt is implicit as the default value q quiet If the mount point to delete is not found this argument specifies that no error be returned Return Codes TABLE H 61 lists the return codes for this subcommand TABLE H 61 Return Codes for Subcommand sp delete mount Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down NWSE_UnknownError 15 Miscellaneous error not captured by other errors Appendix H Service Processor Commands 203 SP Get Mount Subcommand Description Displays the current mount points on the SP Format Command format sp get mounts 1 local MOUNTPOINT H noheader D delim lt DELIMITER gt TABLE H 62 lists the arguments for this subcommand
43. 08 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE C 3 lists the return codes for this subcommand TABLE C 3 Return Codes for Subcommand diags cancel tests Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform operation NWSE_MissingArgument 7 Missing argument s Appendix C Diagnostics Commands 109 Diags Get State Subcommand Description Returns the state of the platform diagnostics control server Format Command format diags get state If the result returned from the command is that the platform is up and ready for diagnostics then you can submit platform diagnostic tests for execution Success Text message The Platform Diagnostics are up and are available to receive test requests Error Text Message The Platform Diagnostics are not up Return Codes TABLE C 4 lists the return codes for this subcommand TABLE C 4 Return Codes for Subcommand diags get state Return Code ID Description NWSE_Succ
44. 178 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 30 lists the arguments for this subcommand TABLE H 30 Arguments for Subcommand sp set jnet Argument Description p platform Specifies the IP address for the platform s sp Specifies the IP address for the SP Note If you change the default addresses of JNET using this command and then re install the platform operating system or reset the SP through the subcommand sp reset to default settings you must re issue the subcommand sp set jnet to re establish the JNET connection Otherwise the connection will be out of sync one address will be modified and one will be re set to the default address Return Codes TABLE H 31 lists the return codes for this subcommand TABLE H 31 Return Codes for Subcommand sp set jnet Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_HostDown 14 Host is down Appendix H Service Processor Commands 179 SP Locate Light Subcommands The subcommands in TABLE H 32 manage the locatelight switch TABLE H 32 SP Locatelight Subcommands Subcommand Description sp get locatelight Reads the value of the locatelight s
45. 4 are sent to the SNMP destination by SP EVENT MIB mib TABLE 3 4 SP Events 1 of 2 Enterprise Trap ID Event 1 2 21 22 23 24 25 26 27 28 spGenericEventInformational spGenericEventWarning spGenericEventCritical spTemperatureEventInformational spTemperatureEventWarning spTemperatureEventCritical spVoltageEventInformational spVoltageEventWarning spVoltageEventCritical spFanEvent Informational spFanEventWarning spFanEventCritical spPlat formMachineCheckEvent Informational spPlat formMachineCheckEventWarning spPlatformMachineCheckEventCritical spPlatformStateChangeEventInformational spPlat formStateChangeEventWarning spPlatformStateChangeEventCritical spPlatformBIOSEventInformational spPlatformBlOSEventWarning spPlatformBiOSEventCritical spGenericEventInformational spGenericEven spGenericEven spTemperaturel spTemperaturel spTemperaturel spVoltageEven tWarning tCritical EventInformational EventWarning EventCritical tInformational Chapter 3 SNMP Server Management 51 52 TABLE 3 4 SP Events 2 of 2 Enterprise Trap ID Event 29 30 31 32 33 37 38 39 40 41 42 spVoltageEventWarning spVoltageEventCritical spFanEventInformational spFanEventWarning spFanEventCritical spPlat formStateChangeEvent Informational spPlat formStateChangeEventWarning spPlatformStateChangeEventCritical spPlatformBIOSEventInformational spPl
46. 5 The leading Os are removed See Step 3 in Updating the Service Processor Base Component on page 23 for more information 7 Press Select to move to the next digit 8 Press Select when finished to return to the left most column 9 Press the button combination for Enter 22 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Updating the Service Processor Base Component To update the SP base component Start the spupdate server on a machine with a Java Runtime Environment JRE by running the following command java jar spupdate jar filename p port The spupdate jar file is located in the spupdate folder of the Network Share Volume NSV In this command filename is an SP image file located in sw_images sp spbase version This sw_images directory contains an SP base image file for each version available By default the server uses port number 52708 If this port number is already in use specify another port using the optional p flag The update server does not start if the file is not found in the specified path Otherwise the server is ready to receive update requests from any SP The update server can simultaneously accept multiple update requests from different SPs Log in to the SP by running the following command ssh spipaddr 1 spuser Run the sp command to start the update process on the SP sp update flash all i ipaddress IPADDRESS p por
47. COM A Note The variable spuser is the user account created when securing the SP The variable spipaddr is the IP address assigned to the SP For more information see Initial Setup of the Service Processor on page 9 You can enable or disable the SOL feature through the SP Enabling the SOL feature To enable the feature run the following command ssh 1 spuser spipaddr platform set console s sp e S 9600 70 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 N Q N Note Ensure that the baud rate value passed to the S argument matches the speed that was specified for the serial redirection feature of the BIOS and the speed used for your boot loader and OS configuration Disabling the SOL feature To disable the feature run the following command ssh 1 spuser spipaddr platform set console s platform Launching an SOL Session To launch an SOL session run the following command ssh spipaddr 1 spuser platform console Terminating an SOL Session To terminate an SOL session Press Control E Press the C key Press the period key You can also terminate an SOL session by terminating the ssh session Press Enter Press the tilde key Press the period key Chapter 4 Further Management Information 71 72 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX A Server Management Commands Summary T
48. Codes for Subcommand platform set power state Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation NWSE_MissingArgument 7 Missing argument s NWSE_Timedout 23 Operation timed out Appendix F Platform Commands 149 Platform Get Hostname Subcommand Description Displays the host name of the current primary platform The data is refreshed only when the platform is rebooted Format Command format platform get hostname H noheader TABLE F 22 lists the argument for this subcommand TABLE F 22 Argument for Subcommand platform get hostname Arguments Description H noheader Suppresses column headers Return Codes TABLE F 23 lists the return codes for this subcommand TABLE F 23 Return Codes for Subcommand platform get hostname Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC clien
49. Codes for Subcommand sp update flash pic Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_Not Found 5 Entity user service file path etc was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_DeviceError 25 Unable to read or write to the device Appendix H Service Processor Commands 225 SP Update Diags Subcommand Description Updates the current version of diagnostics available While the SP functions normally without access to an external file system a file system is required to enable several features including diagnostics The SP software uses a default version of diagnostics However if a new version is released and stored on the Network Share Volume you must explicitly point to that new version to use it Format Command format sp update diags p path lt PATH_TO_DIAGS_FOLDER gt TABLE H 98 lists the argument for this subcommand TABLE H 98 Argument for Subcommand sp update diags Argument Description p path Points to the location of the new diagnostics Return Codes TABLE H 99 lists the return codes for this subcommand TABLE H 99 Return Codes for Subcommand sp update diags Return Code ID Description N
50. Command format sp add snmp destination IP ADDRESS HOSTNAME 212 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 76 lists the argument for this subcommand TABLE H 76 Argument for Subcommand sp add snmp destination Arguments IP ADDRESS HOSTNAMI GJ Description Specifies the IP address or name of the host for the destination you wish to add This argument is repeatable to add multiple destinations at one time however the number of destinations you can create is limited due to memory constraints Return Codes TABLE H 77 lists the return codes for this subcommand TABLE H 77 Return Codes for Subcommand sp add snmp destination Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_RPCConnRefused 12 RPC connection refused NWSE_UnknownError 15 Miscellaneous error not captured by other errors NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_Exist 19 Entity user service or other already
51. D Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation Appendix H Service Processor Commands 181 SP Logfile Subcommands The subcommands in TABLE H 35 manage the SP log files TABLE H 35 SP Logfile Subcommands Subcommand Description sp get logfile Retrieves the event log file configuration sp set logfile Configures the event log file that is the destination of all Event Manager events and notices SP Get Logfile Subcommand Description Retrieves the event log file configuration Format Command format sp get logfile H noheader D delim lt DELIMITER gt TABLE H 36 lists the arguments for this subcommand TABLE H 36 Arguments for Subcommand sp get logfile Argument Description H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string 182 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 37 lists the return codes fo
52. Linux kernel to a newer version requires you to recompile the upgraded IPMI kernel device driver Install the kernel source RPM that matches the version of the upgraded kernel binary RPM package Log in to the server and authenticate as the user root Change to the following directory cd usr src kernel modules openipmi Recompile the module by running the following commands make clean make make install Re test the IPMI kernel device driver and client application by running the following command ipmitool I open chassis status Successful output should look similar to the following System Power on Power Overload false Power Interlock inactive Main Power Fault false Power Control Fault false Power Restore Policy unknown Last Power Event Chassis Intrusion inactive Front Panel Lockout inactive Drive Fault false Cooling Fan Fault false Note On a subsequent reboot the IPMI kernel driver may have to be loaded with the following command modprobe ipmi_kcs_drv Chapter 1 Introduction 19 Daisy Chaining the Servers You can interconnect multiple servers in a daisy chain configuration by using the SP connectors to form a management LAN as shown in FIGURE 1 5 This figure also shows how the servers are connected to external LANs using the platform gigabit connectors C sP 10 100 GB 100 1000 connectors for connectors for management LAN external LANs Mngmt con
53. MI is an industry standard hardware manageability interface specification that provides an architecture defining how unique devices can all communicate with the CPU in a standard way It facilitates platform side server management and remote server management frameworks by providing a standard set of interfaces for monitoring and managing servers With IPMI the software becomes less dependent on hardware because the management intelligence resides in the IPMI firmware layer thereby creating a more intelligently managed server The IPMI solution increases server scalability by distributing the management intelligence closer to the devices that are being managed 27 Baseboard Management Controller In order to perform autonomous platform management functions the processor runs embedded software or firmware Together the processor and its controlling firmware are referred to as the Baseboard Management Controller BMC which is the core of the IPMI structure Tightly integrating an IPMI BMC and management software with platform firmware facilitates a total management solution The BMC is a service processor integrated into the motherboard design providing a management solution independent of the main processor The monitored server can communicate with the BMC through one of three defined interfaces which are based on a set of registers shared between the platform and the BMC Note In these servers the SP has software that emulate
54. Management Commands Command Description access Allows the authorized user to manage and monitor access control and security features of the SP such as users groups SSL and so on See Appendix B Access Commands diags Manages diagnostics tests that are included with your server See Appendix C Diagnostics Commands inventory Allows the authorized user to monitor hardware and software inventory information See Appendix D Inventory Commands ipmi Manages IPMI functions See Appendix E IPMI Commands platform Allows the authorized user to manage and monitor platform activities such as rebooting the platform operating system gathering system status and so on See Appendix F Platform Commands Appendix A Server Management Commands Summary 75 TABLE A 1 Command Server Management Commands Description sensor sp help Reports or sets the value of an environmental sensor or control See Appendix G Sensor Commands Allows the authorized user to manage and monitor the SP configurations such as networking external file system SNMP SMTP SSL event logs and so on See Appendix H Service Processor Commands Returns the following text Available Commands platform access sp sensor inventory ipmi Each of these commands includes help option help Return Codes Every subcommand returns one or more of the following return codes upon completion
55. NoMemory 8 Insufficient memory 214 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 79 Return Codes for Subcommand sp delete snmp destination Return Code ID Description NWSE_RPCConnRefused 12 RPC connection refused NWSE_UnknownError 15 Miscellaneous error not captured by other errors NWSE_FileError 18 File open file missing or a read or write error occurred SP Get SNMP Destinations Subcommand Description Displays the available SNMP destinations IP address or host name to which the SP is configured to send Many networking programs use this information to identify the machine Format Command format sp get snmp destinations Return Codes TABLE H 80 lists the return codes for this subcommand TABLE H 80 Return Codes for Subcommand sp get snmp destinations Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoMemory 8 Insufficient memory NWSE_UnknownError 15 Miscellaneous error not captured by other errors NWSE_FileError 18 File open file missing or a read or write error occurred Appendix H Service Processor Comma
56. PMI Keyboard Controller Style KCS interface driver for the message handler 3 ipmi devintf Linux character device interface for the message handler To force IPMItool to use the device interface you can specify it on the command line ipmitool I open option Installing and Compiling the Driver To install and compile this kernel device driver see Initial Setup of the Service Processor on page 9 LAN Interface for the BMC Note In these servers the SP has software that emulates a BMC The IPMItool LAN interface communicates with the BMC over an Ethernet LAN connection using User Datagram Protocol UDP under IPv4 UDP datagrams are formatted to contain IPMI request response messages with IPMI session headers and Remote Management Control Protocol RMCP headers 36 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Remote Management Control Protocol is a request response protocol delivered using UDP datagrams to port 623 IPMI over LAN uses version 1 of the RMCP to support management both before installing the OS on the server or if the server will not have an OS installed The LAN interface is an authenticated multi session connection messages delivered to the BMC can and should be authenticated with a challenge response protocol with either a straight password key or an MD5 message digest algorithm IPMItool attempts to connect with administrator privilege level as this
57. S POST Codes 187 Boot Block Codes for Flash ROM SP Load Settings Subcommand Format 193 Return Codes 194 SP Get Status Subcommand Format 194 Return Codes 195 SP Get TDULog Subcommand Format 195 Return Codes 197 SP Reboot Subcommand Format 197 Return Codes 198 SP Reset Subcommand 198 Format 198 Return Codes 200 SP Mount Subcommands 201 SP Add Mount Subcommand 197 185 185 186 192 193 194 195 201 Contents xv Format 201 Return Codes 202 SP Delete Mount 203 Format 203 Return Codes 203 SP Get Mount Subcommand 204 Format 204 Return Codes 204 SP SMTP Subcommands 205 SP Get SMTP Server Subcommand 205 Format 205 Return Codes 206 SP Set SMTP Server Subcommand 207 Format 207 Return Codes 207 SP Get SMTP Subscribers Subcommand 208 Format 208 Return Codes 209 SP Update SMTP Subscriber Subcommand 209 Format 209 Return Codes 211 SP SNMP Subcommands 212 SP Add SNMP Destination Subcommand 212 Format 212 Return Codes 213 SP Delete SNMP Destination Subcommand 214 Format 214 Return Codes 214 xvi Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Get SNMP Destinations Subcommand 215 Format 215 Return Codes 215 SP Get SNMP Proxy Community Subcommand 216 Format 216 Return Codes 216 SP Set SNMP Proxy Community Subcommand 216 Format 216 Return Codes 217 SP SSL Subcommands 218 SP Disable SSL Required Subcommand 218 Format 218 Return Codes 218 SP Enable
58. SSL Required Subcommand 219 Format 219 Return Codes 219 SP Get SSL Subcommand 220 Format 220 Return Codes 220 SP Set SSL Subcommand 221 Format 221 Return Codes 221 SP Update Subcommands 222 SP Update Flash All Subcommand 222 Format 222 Return Codes 223 SP Update Flash Applications Subcommand 224 Format 224 Contents xvii Return Codes 224 SP Update Flash PIC Subcommand 225 Format 225 Return Codes 225 SP Update Diags Subcommand 226 Format 226 Return Codes 226 xviii Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Preface This guide explains how to manage the Sun Fire V20z and Sun Fire V40z servers How This Book Is Organized Chapter 1 provides an overview of the ways in which a user can manage the servers See Introduction on page 1 Chapter 2 describes how to manage the servers through the Intelligent Platform Management Interface IPMI See IPMI Server Management on page 27 Chapter 3 describes how to manage the servers through the Simple Network Management Protocol SNMP See SNMP Server Management on page 41 Chapter 4 provides further management information such as how to enable scripting capability Console Redirection over Serial on a Linux based server and Serial over LAN See Further Management Information on page 55 Appendix A contains an overview of the server management commands that you can use to manage the server Following appendi
59. Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Configuring SNMP Trap Destinations Although SNMP traps are generated for events that occur on the SP you must configure where these traps are to be sent There is no default destination for traps You can use the server management subcommands see TABLE 3 2 on the SP to configure SNMP destinations For more information on these subcommands refer to Appendix B TABLE 3 2 Subcommands for Configuring SNMP Destinations Subcommand Description sp get snmp destinations Displays all the available SNMP destination IP addresses and host names to which the SP will send sp add snmp destination Adds a new SNMP destination one IP address or host name at a time sp delete snmp Removes an existing SNMP destination one IP address destination or host name at a time Configuring SNMP Destinations Administration and manager level users can define SNMP destinations to which SNMP events alerts will be sent using this option All users can view the current destinations using read only access The number of destinations you can create is limited due to memory constraints Chapter 3 SNMP Server Management 49 Server MIB Details SNMP uses object identifiers OIDs to provide name variables by which objects are grouped together for easier reference These servers provide agents for the MIBs shown in TABLE 3 3 TABLE 3 3 SNMP MIBs OID Description
60. TABLE F 8 Supplementary Output Column Description Enabled Displays No if the external serial port is connected to the platform Otherwise the external serial port is connected to the SP console you can access the platform serial console through the SP command line by running the subcommand platform console 138 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE F 8 Supplementary Output Column Description Speed Indicates the communications speed of the link Prune Indicates whether ANSI escape code and duplicate information pruning is enabled Log Trigger Indicates the approximate size at which log rotation occurs for example when the file console 0 is removed the current log is moved to console 0 and a new log file is opened Pruning of log file contents happens only when rotation occurs The minimum size for a log file is 64KB the maximum size is 1024KB Return Codes TABLE F 9 lists the return codes for this subcommand TABLE F 9 Return Codes for Subcommand platform get console Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_N
61. This command helps you test and validate different types of configurations that you might be considering for the SP for example configurations involving event forwarding such SNMP SMTP log files or directory services Typically you would have to wait for an event to be generated on the SP in order to validate that these configurations are working properly However using this command you can generate test events that will be routed appropriately according to these configurations Format Command format sp create test events Appendix H Service Processor Commands 185 Return Codes TABLE H 41 lists the return codes for this command TABLE H 41 Return Codes for Subcommand sp create test events Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_NoMemory 8 Insufficient memory SP Get Port 80 Subcommand Description Retrieves the last Port 80 post code from the PRS Port80 register The register is written by platform BIOS during platform boot This command is used to debug platform boot problems Format Command format sp get port80 m monitor TABLE H 42 lists the arguments for this subcommand TABLE H 42 Arguments for Subc
62. WSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_UnknownError 15 Miscellaneous error not captured by other errors 226 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Index A B access commands base component of SP updating 23 add public key 96 baseboard management controller IPMI 28 add trust 91 BIOS POST codes table 187 add user 100 BIOS settings for console redirection 67 delete public keys 98 BMC see baseboard management controller delete trust 93 delete user 101 directory services subcommands 86 disable service 86 enable service 87 get group 80 get groups 81 get map 82 get public key users 97 get services 89 get trusts 94 get users 103 groups subcommands 80 map 83 map subcommands 82 public key subcommands 96 subcommand groups summary 79 trust subcommands 91 unmap 84 update password 104 update user 105 user subcommands 100 Agent X for SNMP 46 autoconfiguring the SP 24 boot block codes for flash ROM 192 buttons operator panel 7 C commands command type overview table 75 return codes summary table 76 ssh using protocol 74 community name for SNMP 46 configuring service processor 9 console redirection over serial BIOS settings configuring 67 getty using 66 grub using 64 LILO using 65 overview 63
63. achine Format Command format sp reboot f forced TABLE H 53 lists the argument for this command TABLE H 53 Argument for Subcommand sp reboot Argument Description f forced Results in a hard power off Appendix H Service Processor Commands 197 Return Codes TABLE H 54 lists the return codes for this command TABLE H 54 Return Codes for Subcommand sp reboot Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoMemory 8 Insufficient memory SP Reset Subcommand Description Restores selected settings of the SP to the default factory configuration The SP configuration files are stored in the directory pstore When you boot the system the SP copies these configuration files from pstore to etc whenever the files are missing from etc Resetting the SP to its default configuration is accomplished by deleting the configuration files in the directory pstore A reboot of the SP is necessary for the SP reset to take effect By default the SP reboots 60 seconds after the subcommand sp reset to default settings executes unless you specify the
64. acter Function f Forces an attach read write g Groups information i Information dump L Toggles logging on off 1 Breaks the sequence list 10 Sends a break per configuration file 11 9 Sends a specific break sequence o Re opens the tty and log file p Replays the last 60 lines x Replays the last 20 lines s Spy read only u Shows the host status v Shows the version information w Shows who is logged on to this console x Shows the console baud information Zz Suspends the connection lt cr gt Ignores aborts the command Prints this message R Replays the last line 000 Sends the character by octal code Under certain circumstances it might be necessary to send a serial break sequence to the platform OS for example to simulate the SysRq key when CONFIG_MAGIC_SYSRQ is defined and enabled in a Linux kernel To perform this operation use the following sequence Ec10 Control E followed by the lowercase letter C the lowercase letter L and the digit 0 The platform console command responds by displaying the string halt sent confirming that the break sequence has been generated In the event that console output becomes corrupted Ecd Eco usually restores proper operation this problem is normally due to flow control issues 136 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Example The following example lists the steps you would perf
65. age section of your configuration files directly Copy the working image section and paste it within the configuration file Make your editing changes to this copied section Chapter 4 Further Management Information 63 64 grub If you use grub there are three steps to enable console redirection over serial these steps all involve editing the grub configuration file m If you are using Red Hat Linux the grub file is etc grub conf a If you are using SUSE Linux the grub file is boot grub menu 1st Note On Red Hat Linux systems the file etc grub conf might be a symbolic link to the file boot grub grub conf 1 Pass the proper console parameters to the kernel 2 Configure the grub menu system to redirect to the proper console 3 Remove any splash images that would prevent the proper serial console display For more information on the parameters refer to the file kernel parameters txt in your kernel documentation For more information on grub run the command info grub Note If the arrow keys do not work through your remote serial concentrator you can use the keystroke combinations of lt CTRL P gt and lt CTRL N gt to highlight the Previous and Next entry respectively Pressing Enter then boots that entry The parameter console ttyS0 tells the system to send the data to the serial port first The parameter console tty0 tells the system to send the data to the KVM second Sun Fire V20z and Sun Fir
66. al POST values 0E Initialize 1 0 component OF Initialize the local bus IDE 10 Initialize power management 11 Load alternate registers with initial POST values 12 Restore CPU control word during warm boot Appendix H Service Processor Commands 187 TABLE H 44 BIOS POST Codes POST Code Description 20 22 24 26 28 29 2A 2C 2E 2F 30 32 33 36 38 3A 3C 3D 41 42 45 46 47 Initialize PCI bus mastering devices Initialize keyboard controller BIOS ROM checksum Initialize cache before memory autosize 8254 programmable interrupt timer initialization 8237 DMA controller initialization Reset programmable interrupt controller Test DRAM refresh Test 8742 keyboard controller Set ES segment register to 4GB Enable gate A20 line Autosize DRAM Initialize POST memory manager Clear 512KB base RAM RAM failure on address line xxxx RAM failure on data bits xxxx of low byte of memory bus Enable cache before system BIOS shadow RAM failure on data bits xxxx of high byte of memory bus Test CPU bus clock frequency Initialize Phoenix Dispatch Manager Warm start shut down Shadow system BIOS ROM Autosize cache Advanced configuration of chipset registers Load alternate registers with CMOS values Initialize extended memory for RomPilot Initialize interrupt vectors POST device initialization Check ROM copyright notice Initialize I20 support 188 Sun Fire V20z and Sun Fire V40z Servers Server Manageme
67. ameters o and 1 are permitted at a time o ou For ADS only Returns the organization unit information Only one of the parameters o and 1 are permitted at a time H noheader Suppresses header output D delim Delimits columns with the specified delimiter Headings are lt DELIMITER gt also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE B 18 lists the return codes for this subcommand TABLE B 18 Return Codes for Subcommand access get services Return Code NWSE_Success NWSE_InvalidUsage NWSE_RPCTimeout NWSE_RPCNotConnected NWSE_InvalidArgument ID 0 Description Command successfully completed Invalid usage bad parameter usage conflicting options specified Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server Unable to connect to the RPC server One or more arguments were incorrect or invalid 90 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Access Trust Subcommands Adding host based trusts provides many to one scripting solutions Once a host equivalence relationship has been created with a client users on that client can remotely execute commands on the SP without being prompted for a password TABLE B 19 lists the commands related to trusted host relationships TABLE B 19 Access Trust Subcommands
68. and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 3 lists the return codes for this subcommand TABLEH 3 Return Codes for Subcommand sp get date Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory SP Set Date Subcommand Description Sets the date and time on the SP RTC Format Command format sp set date DATE_STRING TABLE H 4 lists the argument for this subcommand TABLE H 4 Argument for Subcommand sp set date Arguments Description DATE STRING Specifies the date and time on the Service Processor RTC The date string is a UTC date of the form YYYY MM DD HH MM SS You can use this command to initially set the platform RTC after the platform has lost CMOS backup power If the platform is in the state in which the operating system OS is communicating with the SP the platform time will override the SP time which allows the platform and sp event times to be in sync in the event log Appendix H Service Processor Commands 163 Return Codes TABLE H 5 lists the return codes for this command TABLEH 5 Return Codes for Subcommand sp set date Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad
69. are provided by default for output with more than one column Single column output does not include a heading To suppress headings use the H argument Chapter 4 Further Management Information 61 62 m Data for each column is left aligned with at least one space between columns Numeric data might be right aligned m The D argument allows you to specify a delimiter character when scripting This is very useful in parsing fields with white space m Ifall lines have the same number and type of data values each row is printed to a separate line so variable data can be parsed easily For example executing access get users g monitor returns a list of monitor users each on a separate line Commands that return multiple columns such as inventory get hardware may have a minimal default set of columns and a verbose argument to display all columns Some commands include arguments that allow you to select specific columns to output Other Tips For Best Results m Externalize the set of SP IP addresses into a file to be shared across all of your scripts Consider using a script to create the initial manager account and upload its public key on your SPs Test the output and return codes of each command manually by using SSH to log in to the SP and run the commands individually m Test your scripts on a single staging machine before applying them to your remaining machines m To configure all of your SPs identically cons
70. at formBI0SEventWarning spPlatformBIOSEventCritical Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SNMP Troubleshooting TABLE 3 5 describes a potential issue with SNMP and provides a solution TABLE 3 5 SNMP Troubleshooting Issue Solution SNMP queries to the SP time out The platform OS requires both the NPS driver suite RPM and an active SNMP daemon sharing the SP s community string Chapter 3 SNMP Server Management 53 54 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 CHAPTER 4 Further Management Information Configuring Scripting Capabilities A system administrator can log in to the Service Processor SP using secure shell SSH and issue commands or more commonly write a shell script that remotely invokes these operations Note You must create a valid initial manager account before using SSH The SP includes a setup account that can be used to set up an initial manager account This initial manager user can create additional users The SP includes a suite of commands that enables management and monitoring of the server this suite of commands is referred to as server management commands From the command line for instance you can write data driven scripts that automate configuration of multiple machines The Sun Fire V20z and Sun Fire V40z Servers Network Share Volume CD contains sample scripts for getting started which yo
71. been set the update fails Ensure that the IP address has been set prior to attempting an update For more information refer to the Sun Fire V20z and Sun Fire V40z Servers Installation Guide Refer to Operator Panel on page 6 for general orientation and usage of the operator panel Note Prior to executing this procedure you must start the Java Update Server Refer to Updating the Service Processor Base Component on page 23 for details about starting the Java Update Server To update the SP software When the LCD displays the Service Processor information as shown in the following example press any button 123 45 67 89 OS running The LCD displays the first menu option Menu Server Menu Chapter 1 Introduction 21 2 Press the Forward button until you reach the SP menu Menu SP menu 3 Press Select or Enter to display the SP menu s options SP Menu Set SP IP info 4 Press the Forward button until you reach the Update SP Flash menu option SP Menu Update SP Flash 5 Press Select or Enter 6 A string of 0s displays with the cursor at the left digit Use the Forward and Back buttons to increment or decrement a digit Note You are prompted for an IP address If you attempt to update the SP software using the operator panel when the IP address for the SP has not been set the update fails Note If you need to supply a port address it can be any number between 0 and 6553
72. ber 817 5249 11 Preface xxi xxii Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 CHAPTER 1 Introduction Overview Strong server management capabilities are crucial to maintaining mission critical servers Advance notification of problems and rapid diagnosis and correction are critical functions to an environment in which a few servers bear the bulk of the workload The Sun Fire V20z and Sun Fire V40z servers and their extensive server management capabilities lower costs by reducing failure and by potentially eliminating hands on management This document describes how to perform remote management on the Sun Fire V20z and Sun Fire V40z servers The Sun Fire V20z server is an AMD Opteron processor based enterprise class one rack unit 1U two processor 2P server The Sun Fire V40z server is also an AMD Opteron processor based server but is a three rack unit 3U four processor 4P server The AMD Opteron processor implements the x86 64 bit architecture which delivers significant memory capacity and bandwidth with twice the memory capacity and up to three times the memory bandwidth of existing x86 32 bit servers These servers include an embedded Service Processor SP flash memory RAM a separate Ethernet interface and server management software They come equipped with superior server management tools for greater control and minimum total cost of ownership You can use the command
73. ce xix How This Book Is Organized xix Related Documentation xx Accessing Sun Documentation xxi Third Party Web Sites xxi Contacting Sun Technical Support xxi Sun Welcomes Your Comments xxi Introduction 1 Overview 1 Acronyms 2 Server Management 3 Service Processor 3 Server Management Interfaces 3 SNMP Integration 4 Operator Panel 6 User Groups 8 Initial Setup of the Service Processor 9 Part I Assigning Network Settings to the SP 9 Assigning SP Network Settings Using DHCP Assigning Static SP Network Settings 11 Part Il Securing the Service Processor 13 Creating the Initial Manager Account 13 Enabling IPMI Access on the Server 14 Enabling IPMI Access on a Linux Based Server In Band 14 Enabling IPMI Access on a Solaris Based x86 Server In Band 16 Enabling IPMI LAN Access 17 Enabling IPMI LAN Access on a Linux Based Server In Band 17 Enabling IPMI LAN Access on a Solaris Based x86 Server In Band 18 Alternate Method for Enabling IPMI LAN Access Out of Band 18 Upgrading the Linux Kernel 19 Daisy Chaining the Servers 20 Site Integration 21 Updating the SP Software 21 Updating the Service Processor Base Component 23 Autoconfiguring the SP Optional Method 24 Determining SP and Platform Network MAC Addresses 25 2 IPMI Server Management 27 Baseboard Management Controller 28 Manageability 28 IPMI Compliance and LAN Channel Access 29 Usernames and Passwords 29 Lights Out Management LOM 30 Description 30 Furth
74. cified the Test Details display following the test result line The following data displays after a test is run m Submitted Test Name m Test Handle 112 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 a Test Result for example Passed Failed m Details If you specify the v option the Test Details are displayed indicating detailed information about the test such as high low and nominal values actual values and so on Upon failure the Failure Details are displayed with a text message indicating the cause of failure Return Codes TABLE C 8 lists the return codes for this subcommand TABLEC 8 Return Codes for Subcommand diags run tests Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_MissingArgument 7 Missing argument s Appendix C Diagnostics Commands 113 Diags Start Subcommand Description Starts the SP and platform diagnostics framework You must execute this command before running any tests After
75. curetty 66 Enabling and Configuring BIOS Console Redirection 67 Network Share Volume NSV CD ROM 68 Network Share Volume Structure 68 Serial Over LAN 70 Enabling or Disabling the SOL Feature on the Server 70 Launching an SOL Session 71 Terminating an SOL Session 71 A Server Management Commands Summary 73 Using the ssh Protocol 74 Interactive Shell on the SP 74 Preface Text 74 vi Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Commands 75 Return Codes 76 Access Commands 79 Access Groups Subcommands 80 Access Get Group Subcommand 80 Format 80 Return Codes 80 Access Get Groups Subcommand 81 Format 81 Return Codes 81 Access Map Subcommands 82 Access Get Map Subcommand 82 Format 82 Return Codes 83 Access Map Subcommand 83 Format 83 Return Codes 84 Access Unmap Subcommand 84 Format 84 Return Codes 85 Access Directory Services Subcommands 86 Access Disable Service Subcommand 86 Format 86 Return Codes 87 Access Enable Service Subcommand 87 Format 87 Return Codes 88 Access Get Services Subcommand 89 Contents vii Format 89 Return Codes 90 Access Trust Subcommands 91 Access Add Trust Subcommand 91 Format 91 Generating Host Keys 92 Return Codes 93 Access Delete Trust Subcommand 93 Format 93 Return Codes 94 Access Get Trusts Subcommand 94 Format 94 Return Codes 95 Access Public Key Subcommands 96 Access Add Public Key Subcommand 96 Format 96 Return Codes 97 Access Get Public Key Us
76. d management environment you might want to take advantage of these services There are certain prerequisites and setup required on both the SP and the platform in order to enable and utilize each of these services m SNMP agent on the SP m Proxy forwarder application ProxyAgent RFC 2271 m Agent X RFC 2741 The following diagram illustrates the SNMP architecture and communication paths between the SP and the platform SERVICE PROCESSOR PLATFORM PROXY FORWARDER Default OS SNMP Agent platform object trap path RESPONSE PRIVATE NETWORK PUBLIC NETWORK RESPONSE AGENT X port 705 RESPONSE FIGURE 3 2 SNMP Architecture and Communications 44 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SNMP Agent on the Service Processor The SNMP agent running on the SP facilitates the management and monitoring of the server The SNMP agent can be used to query various types of SP information Refer to FIGURE 3 1 for a list of the MIBs refer to TABLE 3 3 for a detailed description of the MIBs There is no configuration required to use this functionality other than integrating the server MIBs with your desired management station Refer to the procedure for using the SNMP agent on the SP as explained in Integrating MIBs with Third Party Consoles on page 43 Note The SNMP agent on these servers supports SNMP v1 v2c For security reasons there are no settable attributes in this agent
77. d trademarks of Sun Microsystems Inc in the United States and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc Netscape and Mozilla are trademarks or registered trademarks of Netscape Communications Corporation in the United States and other countries The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees wie implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyrigh
78. data is gathered and stored on the Service Processor in a compressed tar file Format Command format sp get tdulog f filename FILENAME or STDOUT c cpuregs CPU REGISTERS p pciregs PCI REGISTERS r reset RESET PLATFORM Appendix H Service Processor Commands 195 TABLE H 50 lists the arguments for this subcommand TABLE H 50 Arguments for Subcommand sp get tdulog Argument filename c cpuregs p pciregs r reset Description Optional The name of the output file to which the log files are copied or the fully qualified path name File names cannot contain the backward relative path reference or the less than symbol lt The following log files are created by default envLog contains the environment variables vpdLog contains raw VPD data Additional log files are created for CPU2 and CPU3 registers The TDU data can also be redirected to stdout If the file name is stdout the output is sent to stdout and the log files are not created An NFS mounted file share must be used to store the output file If you do not provide a file name it creates a file named tdulog tar in logs lt hostname gt where the lt hostname gt is the host name of the SP If the host name is localhost then the MAC address is used instead Reads the K 8 registers GPRs MSRs TCB and machine check from up to four CPUs Reads all PCI registers o
79. de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc Netscape et Mozilla sont des marques de Netscape Communications Corporation aux Etats Unis et dans d autres pays L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconnait les efforts de pionniers de Xerox pour la recherche et le developpement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation i graphique Xerox cette licence couvrant galement les licenci es de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS D CLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON SA Ca Adobe PostScript Contents Prefa
80. dress of the remote server on which the Java spUpdate program is running p port Optional The port number on the remote server on which the Java spUpdate program is listening for SP flash update requests If the port number is not provided the command tries to connect to the default port The default port number is 52708 Return Codes TABLE H 93 lists the return codes for this subcommand TABLE H 93 Return Codes for Subcommand sp update flash all Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage T Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_UnknownError 15 Miscellaneous error not captured by other errors NWSE_ServiceNotAvailable 24 Requested service is not available Appendix H Service Processor Commands 223 SP Update Flash Applications Subcommand Description The SP file system is divided into two componenets Base and Value Add The Base component includes the repository and the Value Add component includes the application software This command copies the file Value Add to the Value Add component of the SP flash The new Value Add image takes effect after you reset the SP Format Command format sp update flash applications f filename TABLE H 94 lists the arguments for this subcommand TABLE H 94 Arguments fo
81. ds for sensors without a parent relationship since an event will never occur for these threshold crossings Appendix G Sensor Commands 157 Sensor Set Subcommand Description Allows you to set some of the data associated with a specific sensor or a class of sensors Format Command format sensor set i id SENSOR_ID i id SENSOR_ID c crithigh VALUE c critlow VALUE w warnhigh VALUE w warnlow VALUE v value on off r reset sensor set t type TYPE_ID C crithigh VALUE c critlow VALUE w warnhigh VALUE w warnlow VALUE v value onloff r reset sensor set R resetall TABLE G 4 lists the arguments for this subcommand TABLEG 4 Arguments for Subcommand sensor set Arguments Description i id Specifies the specific sensor on which to operate You can specify multiple sensors by repeating id t type Specifies the specific sensor class on which to operate for example fan voltage and so on C crithigh Specifies the critical high threshold value for the sensor Setting the string to clear disables the threshold e Setting the string to reset sets the value to the original factory specified value If the value specified ends in a percent sign the threshold is set to that percentage of the nominal value for the sensor e Any other value
82. e Initialize Memory size 192 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 45 Boot Block Codes in Flash ROM Post Code Description EE Shadow Boot Block EF System memory test FO Initialize interrupt vectors F1 Initialize Run Time Clock F2 Initialize video F3 Initialize System Management Manager F4 Output one beep F5 Clear Huge Segment F6 Boot to mini DOS F7 Boot to Full DOS SP Load Settings Subcommand Description Configures an SP with the same configuration as that of another SP You can also perform autoconfiguration from the operator panel to perform this same function For more information see Autoconfiguring the SP Optional Method on page 24 Format Command format sp load settings s sp SP_IP_OR_HOST H noheader TABLE H 46 lists the arguments for this subcommand TABLE H 46 Arguments for Subcommand sp load settings Argument Description s sp The IP address of the machine from which to copy the configuration information H noheader Suppresses header output Appendix H Service Processor Commands 193 Return Codes TABLE H 47 lists the return codes for this subcommand TABLE H 47 Return Codes for Subcommand sp load settings Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgumen
83. e Event Log Message field Click OK Chapter 3 SNMP Server Management 47 SNMP Traps SNMP traps are network management notifications of an event occurring at a managed network node These events can identify problems in the network machines up or down and so on These servers use traps to signal conditions related to the server s health including critical conditions related to physical components the return to a normal state for these components and other situations related to the state of the software running on the SP for example network settings being reconfigured Traps are defined in the MIB files and are generated received and processed by an SNMP management station SNMP trap data is uniquely identified by the MIB Each SNMP trap contains information identifying the server s name IP address and other relevant data about the event Within the server event MIB each trap has the following variables and event bindings see TABLE 3 1 TABLE 3 1 Server Event Traps Event Description EventID Uniquely identifies the event on the SP from where it came EventSource Denotes the source module that generated the event EventComponent Denotes the component ID about which the event refers EventDescription The event message received from its source EventTimeStamplnitial The time at which this event ID was initially generated EventTimeStampLast The most recent time at which this event ID was generated 48
84. e IPMI System Event Log You can use commands to clear the contents of the IPMI SEL Use one of the following commands depending on your OS m For Linux ipmitool I open sel clear m For Solaris ipmitool I lipmi sel clear Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 IPMI Troubleshooting TABLE 2 3 describes some potential issues with IPMI and provides solutions TABLE 2 3 IPMI Troubleshooting Issue You cannot connect to the management controller using IPMItool over LAN You cannot authenticate to the management controller using IPMItool over LAN You have forgotten the password for IPMI access over LAN IPMItool fails when using the open interface Solution Verify the network connection to the management controller and its IP address and verify the channel is enabled using the ipmi get channels command Ensure that you are using the password assigned when you enabled IPMI LAN access from the management controller shell prompt 1 You can reset the IPMI setting reset the SDRR and purge the SEL from the management controller shell by running the command ssh spipaddr 1 spuser ipmi reset a 2 Now re enable IPMI on LAN with the following commands ssh spipaddr 1 spuser ipmi enable channel lan exit He Ensure that the Linux kernel module ipmi_kcs_drv is loaded by running the 1smod command Chapter 2 IPMI Server Management 39 40 Sun Fire V20
85. e V40z Servers Server Management Guide May 2004 A working image section in your grub configuration file should have an entry for the kernel image to boot The stock kernel entry looks like kernel vmlinuz kernel_revision ro root dev sda5 where kernel_revision is simply the kernel version that you are using Change the stock kernel entry of your image to include the console kernel parameters as follows kernel vmlinuz kernel_revision ro root dev sda5 console ttyS0 9600 console tty0 Note These options should all be on one line with no wrap to a second line Add the following two lines to the top of your grub configuration file serial unit 0 speed 9600 terminal serial console Adding these two lines at the beginning of the file sets up your serial port or your KVM as your grub console so that you can remotely or locally select a boot image from the grub menu Comment out or remove the following line from your grub configuration file splashimage hd0 1 boot grub splash xpm gz Removing the splashimage line allows for greater compatibility during your serial connection with this line removed the splash image does not prevent the proper grub menu from displaying LILO LILO uses the append feature in an image section in order to pass to the kernel the proper parameters for using the serial console Enter the consoles in the append statement of the file etc lilo conf append console ttyS0 9600
86. e driver 36 manageability features 28 overview 27 system event log viewing 38 troubleshooting 39 IPMI kernel upgrading 19 IPMI LAN access enabling 17 in band enabling on Linux server 17 in band enabling on Solaris x86 server 18 out of band enabling on Linux server 18 IPMItool command expressions and parameters 32 command options 31 command syntax 30 download sources 30 L LAN diagram 20 lights out management IPMI 30 228 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 LILO using for console redirection 65 logging in with setup account 13 LOM see lights out management M MAC addresses determining 25 management information base MIB for SNMP 42 MIB browser 47 MIB tree diagram 42 N network share volume extracted content 68 structure 68 O operator panel buttons functions defined 7 illustration 6 organization of this book xix overview of book chapters xix overview of server management options 3 P platform commands console 134 console subcommands summary 134 get console 138 get hostname 150 get os state 142 get power state 147 get product id 151 os state subcommands summary 142 power state subcommand summary 147 set console 140 set os state 144 set os state boot 145 set power state 148 subcommand summary table 133 platform MAC address 25 POST codes table 187 propagating SP settings 24 public keys for scripting 58 R related documentation xx return codes summary
87. e is not available 220 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Set SSL Subcommand Description Allows you to use site SSL certificates in the Service Processor environment This command allows you to replace the Server Certificate in the SP Value Add image with your own internally generated certificate and to restore the factory settings Format Command format sp set ssl f sp set ssl c certfile lt FULL PATH OF THE SERVER CERTIFICATE FILE gt k keyfile lt FULL PATH OF PRIVATE KEY FILE gt TABLE H 89 lists the arguments for this subcommand TABLE H 89 Arguments for Subcommand sp set ssl Argument Description Restores factory settings c certfile Flags the names of the files to be installed k keyfile Flags the names of the files to be installed Return Codes TABLE H 90 lists the return codes for this subcommand TABLE H 90 Return Codes for Subcommand sp set ssl Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_ServiceNotAvailable 24 Requested service is not available Appendix H Service Processor Commands 221 SP Update S
88. ed Host Relationships on page 58 and Adding Public Keys on page 58 Authorization Levels Access changes such as adding users or uploading keys typically requires manager level access while most other management tasks can be performed by an administrator level user Return Codes Every subcommand returns a return code upon completion Nowait Argument Most commands complete their execution fairly quickly and are therefore performed synchronously For some longer operations such as rebooting the platform a nowait option is provided so that a script can initiate the operation without waiting for it to return Quiet Argument The delete and update operations such as access delete user sp delete event accept multiple targets To ensure a certain set of targets is deleted on a set of SPs you can use the quiet argument to suppress errors if one of the targets is not found or to suppress interactive warning messages from the platform command Command Output The following list defines common general output Commands that complete successfully return 0 with no success return string Some exceptions are commands that also return vital information Table output interactive warnings and any other non error messages are directed to standard output Commands that return errors display the return codes and a descriptive error string Following are common characteristics of table output from a get command Heading columns
89. ed for passwordless access Chapter 4 Further Management Information 57 58 Note Use scp to copy the files to either tmp or to your home directory The sp commands will then install the file specified on the command line Creating Trusted Host Relationships Adding a trusted host relationship is one way to allow for passwordless access and thus is a means for one to many scripting Once a host equivalence relationship has been created with a client users on that client can remotely execute commands on the Service Processor without being prompted for a password provided one of the following conditions is met m The user s login name on the client is the same as that of a local user on the SP m The user s login on the client belongs to a directory service group that is mapped to an SP administrative group In this case the SSH command executes as a well known auxiliary user on the SP either rmonitor radmin or rmanager Note Support is available for SSH protocol version 2 key types RSA or DSA only If DNS is enabled on the SP the client machine must be specified with its DNS name not an IP address Manager level users can create a trusted host relationship for the specified host from the command line using the access add trust command access add trust c client HOST k keyfile PUBLIC KEY FILE Adding Public Keys Adding a user s public key is another way to allow for passwordless acc
90. equest was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_DeviceError 25 Error deleting trusted host Insufficient space in tmp Access Get Trusts Subcommand Description Requests a list of hosts involved in trust relationships with the SP Format Command format access get trusts 94 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 24 lists the return codes for this subcommand TABLE B 24 Return Codes for Subcommand access get trusts Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation Appendix B Access Commands 95 Access Public Key Subcommands The subcommands listed in TABLE B 25 allow you to manage public keys and public key users TABLE B 25 Access Public Key Subcommand
91. er Guide 817 5248 TABLE C 1 Diagnostics Subcommand Groups Subcommand Description diags cancel tests diags diags diags diags diags get state get tests run tests start terminate Cancels one or more diagnostic tests resulting in the deletion of the results data Returns the state of the platform diagnostics control server Returns data describing the diagnostic tests that are available and their requirements and parameters Submits one or more diagnostic tests for execution Starts the Service Processor SP and platform diagnostics framework Terminates all diagnostics tests and terminates the diagnostics subsystem Note Every command returns a return code upon completion 107 Diags Cancel Tests Subcommand Description Cancels one or more diagnostic tests resulting in the deletion of results data Format Command format diags cancel tests t test TEST HANDLE a all H noheader TABLE C 2 lists the arguments for this subcommand Note Specifying no arguments cancels all tests for each device in the server TABLE C 2 Arguments for Subcommand diags cancel tests Arguments Description t test Specifies the test to cancel NOTE The TEST HANDLE is the same TEST HANDLE that is output to the screen when you submit the test a all Cancels all tests H noheader Suppresses header output 1
92. er Information 30 Syntax 30 Options 31 Expressions 32 iv Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 IPMI Linux Kernel Device Driver 36 LAN Interface for the BMC 36 Files 37 Viewing the IPMI System Event Log 38 Clearing the IPMI System Event Log 38 IPMI Troubleshooting 39 SNMP Server Management 41 Simple Network Management Protocol 41 SNMP Integration 42 SNMP Management Information Base MIB 42 Sun Fire V20z and Sun Fire V40z Servers MIB Tree 43 Integrating MIBs with Third Party Consoles 43 Configuring SNMP on Your Server 44 SNMP Agent on the Service Processor 45 Proxy Agent 45 Setting the Community Name 46 AgentX 46 Using a Third Party MIB Browser 47 Setting Logging Options 47 SNMP Traps 48 Configuring SNMP Trap Destinations 49 Configuring SNMP Destinations 49 Server MIB Details 50 SNMP Troubleshooting 53 Further Management Information 55 Configuring Scripting Capabilities 55 Using Shell Scripts 56 Contents v Remote Scripting Using SSH 56 Configuring Multiple Systems for Scripting 57 Generating Host Keys 57 Creating Trusted Host Relationships 58 Adding Public Keys 58 Generating a Host Key Pair 59 Enabling SSH Access Using Trusted Hosts 59 Enabling SSH Access Using Public Keys 60 Guidelines for Writing Server Management Command Scripts 61 Command Output 61 Other Tips For Best Results 62 Console Redirection Over Serial on a Linux based Server 63 grub 64 LILO 65 getty 66 se
93. ers Subcommand 97 Format 97 Return Codes 98 Access Delete Public Key Subcommand 98 Format 98 Return Codes 99 Access User Subcommands 100 Access Add User Subcommand 100 Format 100 Return Codes 101 Access Delete User Subcommand 101 viii Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Format 101 Return Codes 102 Access Get Users Subcommand 103 Format 103 Return Codes 103 Access Update Password Subcommand 104 Format 104 Return Codes 104 Access Update User Subcommand 105 Format 105 Return Codes 106 Diagnostics Commands 107 Diags Cancel Tests Subcommand 108 Format 108 Return Codes 109 Diags Get State Subcommand 110 Format 110 Return Codes 110 Diags Get Tests Subcommand 111 Format 111 Return Codes 111 Diags Run Tests Subcommand 112 Format 112 Return Codes 113 Diags Start Subcommand 114 Format 114 Return Codes 114 Diags Terminate Subcommand 116 Contents ix x Format 116 Return Codes 116 Inventory Commands 117 Inventory Compare Versions Subcommand 118 Format 118 Return Codes 119 Inventory Get Hardware Subcommand 119 Format 119 Return Codes 120 Inventory Get Software Subcommand 121 Format 121 Return Codes 121 Inventory Get All Subcommand 122 Format 122 Return Codes 122 IPMI Commands 123 IPMI Disable Channel Subcommand 124 Format 124 Return Codes 124 IPMI Enable Channel Subcommand 125 Format 125 Return Codes 125 IPMI Get Channels Subcommand 126 Format 126 Return Code
94. es automatic redirect to secure HTTP URLs With SSL disabled HTTP requests are serviced directly without redirecting to HTTPS HTTPS requests continue to be secure Format Command format sp disable ssl required Return Codes TABLE H 85 lists the return codes for this command TABLE H 85 Return Codes for Subcommand sp disable ssl required Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage il Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation 218 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 85 Return Codes for Subcommand sp disable ssl required Return Code ID Description NWSE_NoMemory 8 Insufficient memory NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_ServiceNotAvailable 24 Requested service is not available SP Enable SSL Required Subcommand Description Enables automatic redirect to secure HTTP URLs With SSL enabled HTTP requests are automatically redirected to equivalent HTTPS requests to maintain site security SSL version 0 9 6j is supported Format Command format sp enable ssl required Return Codes TABLE H 86 lists the return codes for this command TABLE H 86 Return Codes for Subcommand sp enable ssl required Return Code ID Description NWSE_Success 0 Command successf
95. ess 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_DeviceError 25 Unable to read or write to the device 110 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Diags Get Tests Subcommand Description Returns data describing the diagnostic tests that are available This data includes the specific test name and the module to which the test applies Format Command format diags get tests a all H noheader D delim lt DELIMITER gt TABLE C 5 lists the arguments for this subcommand TABLEC 5 Arguments for Subcommand diags get tests Arguments Description a all Specifies to return information for all tests in the server Specifying no arguments also returns all tests available for each device in the server H noheader Suppresses header output D delim Delimits columns with the specified delimiter Headings are also lt DELIMITER gt delimited unless suppressed The delimiter can be any character or string Return Codes TABLE C 6 lists the return codes for this subcommand TABLEC 6 Return Codes for Subcommand diags get tests Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by
96. ess and thus provide one to many scripting Once a public key for a specific user has been installed on the SP that user can remotely execute commands on the SP without being prompted for a password if that user has installed the associated private key on the client Note Support is available for SSH protocol version 2 key types RSA or DSA only Only local users can add public keys Users who obtain authorization from directory services group mappings are not able to add public keys Local admin level or manager level users can add public keys using the access add public key command Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 access add public key 1 PUBLIC KEY FILE u user The public key file is your RSA or DSA key Up to 10 users can install public keys only one key per user is allowed Admin level users can only add their own public key Manager level users can add a public key for any local user If the user is not specified in the command the current user is the default Note The maximum supported key length is 4096 bits Generating a Host Key Pair To establish a trusted host relationship you must set up a host key which is used to authenticate one host to another Follow these steps to generate a host key pair by copying the public key to the SP to which you want passwordless access Execute the following command ssh keygen t rsa N Accept the defau
97. ettings Note Every command returns a return code upon completion 123 IPMI Disable Channel Subcommand Description Allows you to disable one of two IPMI channels Format Command format ipmi disable channel sms lan TABLE E 2 lists the arguments for this subcommand TABLEE 2 Arguments for Subcommand ipmi disable channel Arguments Description sms The ID of the channel to disable for the System Interface not case sensitive lan The ID of the channel to disable for the LAN Interface not case sensitive Return Codes TABLE E 3 lists the arguments for this subcommand TABLE E 3 Return Codes for Subcommand ipmi disable channel Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation 124 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 IPMI Enable Channel Subcommand Description Allows you to enable one of two IPMI channels Format Command format ipmi enable channel sms lan TABLE E 4 lists the arguments for this subcommand TABLEE 4 Arguments for Subcommand ipmi enable channel Arguments Description sms The ID of the channel to enable for the System Interface not case sensitive lan The ID of the channel to
98. f the community to configure There are no restrictions on the length of the community strings common names are private and public The default name of the community string is private If you run the subcommand sp get snmp proxy community without setting it the return valule is private Otherwise you can set it to any string Return Codes TABLE H 83 lists the return codes for this subcommand TABLE H 83 Return Codes for Subcommand sp set snmp proxy community Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server Appendix H Service Processor Commands 217 SP SSL Subcommands The subcommands in TABLE H 84 manage SSL capabilities TABLE H 84 SP SSL Subcommands Subcommand Description sp disable ssl required Disables forced use of the secure HTTP https protocol sp enable ssl required Enables forced use of the secure HTTP https protocol sp get ssl Determines if the Apache Web server is using factory supplied files or user supplied files sp set ssl Allows you to use site SSL certificates in the SP environment SP Disable SSL Required Subcommand Description Disabl
99. fied NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_Exist 19 Entity user service or other already exists NWSE_NotRecognized 20 Request not understood NWSE_NotMounted 21 File system is not mounted NWSE_InvalidOpForState 22 Invalid operation for current state NWSE_TimedOut 23 Operation timed out NWSE ServiceNotAvailable 24 Requested service is not available NWSE_DeviceError 25 Unable to read or write to the device NWSE_LimitExceeded 26 Limit has been exceeded Appendix A Server Management Commands Summary 77 78 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX B Access Commands The access command validates a user s authority or controls authorization services Using the access command you can retrieve information about user groups add a user to or delete a user from a group and specify a mapping between site defined administrative groups and the administrative groups that are used to authorize actions on the Service Processor TABLE B 1 lists the groups of access subcommands TABLE B 1 Access Subcommand Groups Subcommand Group access access access access access access groups map public key services trust user Description Returns the authorization group for a specific user or a list of defined groups Maps unmaps and returns a list of existing site specified group names the directory se
100. form command reports or changes some aspect of the state of the platform TABLE F 1 lists the groups of platform subcommands TABLE F 1 Platform Subcommand Groups Subcommand Group Description platform platform platform platform platform console os state power state get hostname get product id Manages access to the platform serial console Manages the current state of the operating system OS Manages the state of the platform power Displays the host name of the current primary platform Displays the product ID for the current system Note Every command returns a return code upon completion 133 Platform Console Subcommands The subcommands listed in TABLE F 2 allow you to manage access to the platform serial console TABLE F 2 Platform Console Subcommands Subcommand Description platform console Provides access to the platform serial console platform get console Retrieves the configuration of the Service Processor SP access to the platform serial console platform set console Configures the SP access to the platform serial console Platform Console Subcommand Description For remote management capability this command provides access to the platform serial console Used in conjunction with the subcommand platform set console and the appropriate BIOS platform OS settings this command enables you to view the platform serial console while logged in to the SP Format
101. g arguments are optional but you must specify at least one TABLE B 40 Arguments for Subcommand access update user Argument Description u user The name of the user to update p password The user s new password The p and g options are optional but you must specify at least one g group The new group to which to reassign to the user The p and g options are optional but you must specify at least one Appendix B Access Commands 105 Return Codes TABLE B 40 lists the return codes for this subcommand TABLE B 41 Return Codes for Subcommand access update user Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation 106 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX C Diagnostics Commands The diags commands allow you to manage the diagnostics tests TABLE C 1 lists the groups of diags subcommands Note The diagnostics commands are also provided in the Sun Fire V20z Server Us
102. g ssh to access the SP from a remote system that had previously logged into the SP causes a failure with a message about the Remote Host Identification changing because the ssh key on the SP has changed The remote system must delete its ssh public key entry for the SP in order to ssh into the SP successfully This option deletes all the files in the directory pstore ssh Resets user authentication settings to their default configuration When the SP reboots all user accounts will have been deleted and you cannot log into the SP remotely through ssh Reboots the SP immediately Note If you change the default addresses of JNET using this command and then re install the platform operating system or reset the SP by running the subcommand sp reset to default settings you must re issue the subcommand sp set jnet to re establish the JNET connection Otherwise the connection will be out of sync one address will be modified and one will be re set to the default address Appendix H Service Processor Commands 199 Return Codes TABLE H 56 list the return codes for this command TABLE H 56 Return Codes for Subcommand sp reset Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may
103. ge body and a descriptive subject line the same subject as used for long messages The short email format is intended to be used with pagers and other wireless access devices with which message size constraints may prevent reception of the long format message 208 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 71 lists the return codes for this subcommand TABLE H 71 Return Codes for Subcommand sp get smtp subscribers Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage TL Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5 Entity user service file path etc was not found SP Update SMTP Subscriber Subcommand Description Updates the information for an existing SMTP subscriber Format Command format sp update smtp subscriber n name NAME r recipients ADDRESS LIST TABLE H 72 lists the arguments for this subcommand TABLE H 73 lists the default SMTP subscribers Appendix H Service Processor Commands 209 Note All options replace the existing values with the new value Unspecified options leave existing settings as they are For example if y
104. h the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string TABLE H 16 lists the return codes for this subcommand TABLE H 16 Return Codes for Subcommand sp get events Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage ai Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NotFound 5 Entity user service file path or other not found NWSE_NoMemory 8 Insufficient memory 170 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Hostname Subcommands The subcommands in TABLE H 17 manage the SP host and domain TABLE H 17 SP Hostname Subcommands Subcommand Description sp get hostname Displays the current host name and optionally the domain name of the SP sp set hostname Resets the host name or domain name of the SP to the specified name SP Get Hostname Subcommand Description Displays the current host name and optionally the domain name of the SP This name is used by many of the networking programs to identify the machine It is also used to identify a logging subdirecto
105. he idle background state For every action that you confirm feedback displays on the panel to indicate success failure or that the action has been initiated The Back and Forward buttons automatically scroll repeating the action as long as the button is held down After holding the button down a few seconds auto scrolling begins and rapidly increments or decrements the value Chapter 1 Introduction 7 User Groups Administrators can define several different user groups or types on the server Capabilities of the different user types are defined in TABLE 1 3 For example when you log in to the system the first time using the setup account the first thing you must do is set up the initial manager account so that other user accounts can be managed see Creating the Initial Manager Account on page 13 for details TABLE 1 3 User Types User Type Capability monitor Read only access for sensor data and log displays admin All capabilities except user account management and SP field upgrades manager All capabilities except SP field upgrade service SP field upgrades 8 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Initial Setup of the Service Processor This procedure describes the steps for the initial setup of the SP Part I Assigning Network Settings to the SP This section contains two alternate methods you can use to define SP network settings a Assigning SP Netwo
106. he initial manager account by following this procedure Using an SSHv1 or SSHv2 client connect to the IP address of the SP Authenticate as the user setup with no password required ssh sp_ip_address 1 setup Follow the on screen prompts to create the initial manager account After you create the initial manager account the setup account is deleted and you are logged out of the server You can then log in using the new manager account from which you can create other user accounts Note If you are prompted for a password this indicates that the SP has already been secured If you do not know the management user name and password you can reset the SP from the operator panel Note The IP address user name and password that you configure are referred to in subsequent examples as the spipaddr spuser and sppasswd Chapter 1 Introduction 13 Enabling IPMI Access on the Server This section contains two alternate procedures one for a Linux based server and one for a Solaris based x86 server Use the procedure that corresponds to your OS a Enabling IPMI Access on a Linux Based Server In Band on page 14 m Enabling IPMI Access on a Solaris Based x86 Server In Band on page 16 Enabling IPMI Access on a Linux Based Server In Band 1 Log in to the server and authenticate as the user root 2 Install the custom openIPMI Linux kernel driver from the Sun Fire V20z and Sun Fire V40z Servers Documentat
107. he request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation Access Delete Public Key Subcommand Description All users can execute this command to remove their own public key Manager level users can execute this command to remove the public key for any user Format Command format access delete public key u user USER a all q quiet TABLE B 29 lists the arguments for this subcommand TABLE B 29 Arguments for Subcommand access delete public key Arguments Description u user The user whose public key will be removed Defaults to the current user If USER is not specified This argument is repeatable to remove multiple public keys at one time a all Removes all public keys q quiet If the user to delete is not found this argument specifies that no error be returned 98 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 30 lists the return codes for this subcommand TABLE B 30 Return Codes for Subcommand access delete public key Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the
108. he service processor SP includes a suite of commands that enables management and monitoring of the server this suite of commands is referred to as the server management commands Note This appendix provides an overview of the server management command types that are available on the SP For a detailed description of the subcommands arguments and return codes for each command type refer to the appendixes in this guide as described in TABLE A 1 73 Using the ssh Protocol You must use ssh to execute these commands on the service processor SP There are two ways to do this m Use the interactive shell on the SP m Preface each command with a set piece of text Interactive Shell on the SP To use the interactive shell Log into and authenticate on the interactive shell by running the command ssh 1 spipaddr spuser Preface Text Preface each command with the following text ssh 1 spipaddr spuser 74 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Commands The server management commands take arguments perform one or more actions and display the result or text to the standard output device Commands are grouped by similar function each command has numerous subcommands supporting functions within that grouping Note Every command except help returns a return code upon completion See Return Codes on page 76 for a summary TABLE A 1 Server
109. his account to authenticate itself to the LDAP interface of the active directory server A Windows administrator can create the keytab for this account using the following command ktpass princ lt logon gt lt domain gt pass lt password gt mapuser lt logon gt out lt output filename gt The keytab file must then be securely transferred to the SP using an encrypted file transfer mechanism The clock on the SP must be accurate and DNS must be set up meaning that the SP must have a DNS record If a directory service has been previously enabled you can specify the following command and options the saved settings are then used to re enable the service access enable service t lt nis ads gt Return Codes TABLE B 16 lists the return codes for this subcommand TABLE B 16 Return Codes for Subcommand access enable service Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server 88 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE B 16 Return Codes for Subcommand access enable service Return Code ID Description NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more a
110. his subcommand TABLEE 7 Return Codes for Subcommand ipmi disable pef Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation Appendix E IPMI Commands 127 IPMI Enable PEF Subcommand Description Allows you to enable platform event filtering PEF Format Command format ipmi enable pef Return Codes TABLE E 8 lists the return codes for this subcommand TABLEE 8 Return Codes for Subcommand ipmi enable pef Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage i Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_ServiceNotAvailable 24 Requested service is not available 128 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 IPMI Get Global Enables Subcommand Description Displays the list of IPMI global enables and their current value Format Command format ipmi get global enables Return Codes TABLE E 9 lists the return codes for this subcommand TABLEE 9 Return Codes for Subcommand ipmi get global enables Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options spec
111. ider configuring a single SP and then using the sp load settings command to synchronize that configuration on the remaining machines Note If running the script from the SP there are a limited number of commands not a full bash environment Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Console Redirection Over Serial on a Linux based Server Caution Redirecting the console over serial is a procedure intended for advanced users of Linux only You can seriously disrupt the proper functioning of the server or render the server unbootable if you introduce a problem in the configuration files Note Instructions for console redirection on a Solaris based server are not yet available Redirecting the console interaction over the serial port allows the user another method to monitor the server The goal of these configurations is to configure the bootloader to redirect its output pass the kernel the proper parameters and configure a login session on the serial port This section describes how to configure these options The BIOS redirects console output to serial by default 9600 8N1 no handshake until a bootloader program is run from the hard disk drive The bootloader must be configured to support the serial console in addition to the keyboard video and mouse KVM console Two common bootloaders are grub and Linux Loader LILO Caution Do not edit the working im
112. ified Appendix E IPMI Commands 129 IPMI Set Global Enable Subcommand Description Allows you to set the value of several IPMI global enable variables Format Command format ipmi set global enable n name GLOBAL NAM d disabled TABLE E 10 lists the arguments for this subcommand TABLE E 11 provides information about the aliases e enabled TABLE E 10 Arguments for Subcommand ipmi set global enable Arguments Description n name The name of one of the IPMI global enable variables see TABLE E 11 You can use either a quoted long string or an alias without quotes for the list of global enables e enabled Turns the channel on d disabled Turns the channel off TABLE E 11 Information about the aliases Alias Name String Values Default oem0 OEMO Enable Enabled Disabled Disabled oem1 OEM1 Enable Enabled Disabled Disabled oem2 OEM 2 Enable Enabled Disabled logging Enable System Event Logging Enabled Enabled Disabled 130 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE E 11 Information about the aliases Alias Name String Values Default msg_buf Enable Event Message Buffer Enabled Disabled msg_buf_interrupt Enable the Event Message Buffer Enabled Full Disabled msg_queue_interrupt Enable Receive Message Queue Enabled Enabled Interrupt Disabled Return Codes TABLE E 12 lists the return codes for this subcom
113. ifies the gateway the default value is the existing gateway If you specify the nowait option loss of connectivity will occur some time after the command returns If you do not specify the nowait option your connections to the SP will be lost before the command returns Return Codes TABLE H 26 lists the return codes for this subcommand TABLE H 26 Return Codes for Subcommand sp set ip Return Code NWSE_Success NWSE_InvalidUsage NWSE_InvalidArgument NWSE_NoPermission NWSE_NoMemory NWSE_Busy NWSE_RPCConnected NWSE_RPCConnRefused NWSE_NoRouteToHost NWSE_HostDown NWSE_UnknownError NWSE_GatewayOf fNet NWSE_NetMaskIncorrect ID 0 Description Command successfully completed Invalid usage bad parameter usage conflicting options specified One or more arguments were incorrect or invalid Not authorized to perform this operation Insufficient memory Device or resource is busy RPC client already connected RPC connection refused No route to host network down Host is down Miscellaneous error not captured by other errors Gateway address is not on network An inappropriate netmask was specified 176 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP JNET Address Subcommands The JNET address is used for communications between the SP and the platform The subcommands in TABLE H 27 manage the SP JNET address TABLE H 27 SP JNET Subcommands
114. inate Subcommand Description Terminates all diagnostics tests and the diagnostics session Format Command format diags terminate Return Codes TABLE C 10 lists the return codes for this subcommand TABLE C 10 Return Codes for Subcommand diags terminate Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_MissingArgument 7 Missing argument s 116 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX D Inventory Commands The inventory command reports on the inventory of hardware and software for a Sun Fire V20z server TABLE D 1 lists the groups of inventory subcommands that you can use to retrieve specific information about hardware or software TABLE D 1 Inventory Subcommands Groups Subcommand Description inventory compare versions Returns a list of all installed software packages and the inven inven inven tory get hardware tory get software tory get all version differences with
115. ion and Support Files CD The drivers are located in the CD directory support sysmgmt Browse to the OS variant installed on your server The options are m redhat rhel3 for Red Hat Enterprise Linux version 3 32 bit mode uses the architecture type i386 64 bit mode uses architecture type x86_64 m suse sles8 for SUSE Enterprise Linux version 8 32 bit mode uses the architecture type 1386 64 bit mode uses architecture type x86_64 m suse suse9 for SUSE 9 Professional 3 Ensure that the kernel source RPM is already installed on your distribution by running the command rpm qvi kernel source If this utility reports that the kernel source software package is not installed install the kernel source RPM that is current for your installed Linux distribution m On SUSE distributions install the kernel source RPM by running the command yast2 m On RedHat distributions download the current kernel source RPM to a temporary directory such as tmp Install the package by running the command rpm ivh tmp kernel source rpm 4 Install the openIPMI Linux kernel driver RPM a Browse to the OS variant installed on your server The options are a redhat rhel3 for Red Hat Enterprise Linux version 3 32 bit mode uses the architecture type i386 64 bit mode uses architecture type x86_64 a suse sles8 for Suse Enterprise Linux version 8 32 bit mode uses the architecture type i386 64 bit
116. is active Cannot be used with d 1 log size Select the trigger size in KB for console log rotation The acceptable values for log size are between 64 and 1024 inclusive 140 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE F 10 Arguments for Subcommand platform set console Arguments Description n noprune Indicates that the platform console log should be the raw console data Cannot be used with p p prune Indicates that the platform console log is to be cleaned of ANSI sequences and pruned of duplicated information Cannot be used with n s serial Specify whether the serial port is connected to the platform sp platform COMA port or the SP serial console Cannot be used with e platform d platform p platform n platform s platform 1 platform Return Codes TABLE F 11 lists the return codes for this subcommand TABLE F 11 Return Codes for Subcommand platform set console Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or i
117. is interpreted as the actual value to which to set the threshold c critlow Specifies the critical low threshold value for the sensor Setting the w warnhigh w warnlow string to clear disables the threshold Specifies the warning high threshold value for the sensor Setting the string to clear disables the threshold Specifies the warning low threshold value for the sensor Setting the string to clear disables the threshold 158 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLEG 4 Arguments for Subcommand sensor set Arguments Description v value Sets the value of the sensor r reset Resets all thresholds for the specified sensor s to the factory defaults R resetall Resets all thresholds for all sensors to the factory defaults Return Codes TABLE G 5 lists the arguments for this subcommand TABLEG 5 Return Codes for Subcommand sensor set Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NotFound 5 Entity user service file
118. is into the soft off state S4 S5 state NOTE This command does not initiate a clean shutdown of the operating system prior to powering off the server Provides a power off interval of at least 1 second No action should occur if chassis power is in 54 55 state but it is recommended to check the power state first and then only issue a power cycle command if the server power is on or in a lower sleep state than 54 55 Performs a hard reset Prints the current configuration for the given channel Sets the given parameter on the given channel Sets the IP address for this channel Sets the netmask for this channel Sets the MAC adddress for this channel Sets the default gateway IP address Sets the default gateway MAC address Sets the backup gateway IP address Sets the backup gateway MAC address Sets the null user password Enables the user access mode Sets the LAN channel access mode Sets the IP address source As a source you can indicate none unspecified static manually configured static IP address dhcp address obtained by BMC running DHCP bios address loaded by BIOS or system software 34 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE 2 2 Expressions and Parameters for IPMItool 4 of 4 Expression Parameter Sub parameter Description and examples arp respond Sets the BMC generated ARP responses on off arp generate Sets the BMC generated gratuitou
119. is required to perform chassis power functions With the I option you can direct IPMItool to use the LAN interface ipmitool I lan option address password To use the LAN interface with IPMItool you must provide a host name on the command line The password field is optional if you do not provide a password on the command line IPMItool attempts to connect without authentication If you specify a password it uses MD5 authentication if supported by the BMC otherwise it will use straight password key Files The file dev ipmi0 is a character device file used by the OpenIPMI kernel driver Examples If you want to remotely control the power of an IPMI over LAN enabled server you can use the following commands ipmitool I lan H spipaddr P sppasswd chassis power on The result returned is Chassis Power Control Up On ipmitool I lan H spipaddr P sppasswd chassis power status The result returned is Chassis Power is on Chapter 2 IPMI Server Management 37 38 Viewing the IPMI System Event Log To view the System Event Log SEL use IPMItool The out of band command is ipmitool I lan H spipaddr P ipmipasswd sel list The in band command using OpenIPMI on a Linux based server or LIPMI on a Solaris based server is ipmitool I open sel list Note To receive more verbose logging messages you can run the following command ssh 1 spuser spipaddr sp get events Clearing th
120. ists the return codes for this subcommand TABLE D 3 Return Codes for Subcommand inventory compare versions Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server Inventory Get Hardware Subcommand Description Returns detailed information for all field replaceable hardware components By default the name type OEM manufacture date hardware revision and part number display for each component Format Command format inventory get hardware v verbose H noheader D delim lt DELIMITER gt TABLE D 4 lists the arguments for this subcommand TABLE D 4 Arguments for Subcommand inventory get hardware Arguments Description v verbose Displays all columns H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Appendix D Inventory Commands 119 To obtain the board revision product ID and PRS revision you can run the following commands inventory get hardware D awk F PRS print 8 invent
121. le to connect to the RPC server 206 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Set SMTP Server Subcommand Description Configures the SP SMTP client with the information for the remote SMTP server including the address and optional port number Format Command format sp set smtp server f from FROM FIELD IP OR HOSTNAME OF SMTP SERVER TABLE H 67 lists the arguments for this subcommand TABLE H 67 Arguments for Subcommand sp set smtp server Arguments Description from Specifies the from field for the SMTP server IP OR HOSTNAME OF SMTP SERVER Specifies the IP address or the host name of the SMTP server The value you supply is prepended onto amp hostname ip_address The default value is system For example if you enter admin for sp_22 email messages are sent from admin sp_22 If the host name is not set the IP will be used as follows admin 10 10 30 55 Return Codes TABLE H 68 lists the return codes for this subcommand TABLE H 68 Return Codes for Subcommand sp set smtp server Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 U
122. line interface CLI SNMP integration with third party frameworks or IPMI to configure and manage the platform with the SP The dedicated SP provides complete operating system independence and maximum availability of server management Acronyms TABLE 1 1 defines the acronyms found in this document TABLE 1 1 Acronyms Acronym Explanation ACPI Advanced Configuration and Power Interface ARP Address Resolution Protocol BMC Baseboard Management Controller CRU Customer Replaceable Unit DPC Direct Platform Control FRU Field Replaceable Unit grub Grand Unified Bootloader IPMI Intelligent Platform Management Interface KCS Keyboard Controller Style KVM Keyboard video and mouse LAN Local Area Network LILO Linux Loader LOM Lights Out Management MIB Management Information Base RMCP Remote Management Control Protocol SDR Sensor Data Record SEL System Event Log SNMP Simple Network Management Protocol SOL Serial Over LAN SP Service Processor SSU System Setup Utility SunMC Sun Management Center UART Universal Asynchronous Receiver Transmitter UDP User Datagram Protocol WAN Wide Area Network 2 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Server Management There are several options for remotely managing a Sun Fire V20z or Sun Fire V40z server m Lights Out Management LOM through IPMItool a Simple Network Management Protocol SNMP Service Processor The Sun Fire V20z a
123. llowing message displays when autoconfiguration is running SP AutoConfigure in progress Note If the autoconfiguration is unsuccessful a failure message displays Press any button to clear it Determining SP and Platform Network MAC Addresses Use the following commands if you need to determine the MAC address of your server s SP or platform ssh spipaddress 1 spusername sp get mac ssh spipaddress 1 spusername platform get mac Chapter 1 Introduction 25 26 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 CHAPTER 2 IPMI Server Management Server manufacturers today have to re invent how each new server manages itself The hardware and software design for one server does not necessarily work with another Every server supplier provides basic monitoring and data collection functions but no two do it exactly the same These proprietary implementations for manageability only complicate the problem The standardization of server based management called Intelligent Platform Management Interface IPMI provides a solution IPMI allows you to interconnect the CPU and devices being managed It allows for Easy replication of the monitoring functions from server to server Support for a reasonably large number of monitoring devices Common driver level access to management instrumentation More cost effective implementations Increased scalability of the server management functions IP
124. lt values installing to the following directory SHOME ssh id_rsa The following files are created SHOME ssh id_rsa SHOME ssh id_rsa pub Enabling SSH Access Using Trusted Hosts Follow these steps to add users to the local etc password file to attempt trusted host access to the Service Processor Set up your host keys by executing the following command ssh host config Enable access for clients by launching a Bash shell a If you want all network accounts added execute mkpasswd gt gt etc passwd a If you want just local accounts added execute mkpasswd 1 gt gt etc passwd Issue the following commands as a manager level user on the client to establish a trusted host relationship manager1 is used in the example in this step a Copy the client key to tmp on the SP scp etc ssh_host_dsa_key pub manager1 sp test com tmp Chapter 4 Further Management Information 59 b Authenticate yourself for the scp command by entering the password for your manager level user c Add the client key to the set of trusted hosts for this SP ssh sp test com access add trust c client test com k tmp ssh_host_dsa_key pub d Authenticate yourself for the ssh command From this point any user with the same login on both sp test com and client test com has access without requiring a password to the like named account on sp test com 4 Create or modify the file etc ssh_config to ensure it contains the followi
125. mand TABLE E 12 Return Codes for Subcommand ipmi set global enable Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation Appendix E IPMI Commands 131 IPMI Reset Subcommand Description Resets IPMI information back to default factory settings Format Command format ipmi reset s sdrr c config p password a all TABLE E 13 lists the arguments for this subcommand TABLE E 13 Arguments for Subcommand ipmi reset Arguments Description s sdrr Copies the original database file to pstore c config Deletes the configuration file and global enables p password Deletes the password file a all Performs the functions of all the parameters Return Codes TABLE E 14 lists the return codes for this subcommand TABLE E 14 Return Codes for Subcommand ipmi reset Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation 132 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX F Platform Commands The plat
126. mode uses architecture type x86_64 a suse suse9 for Suse 9 Professional 14 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 b Install the openIPMI RPM file by running the command rpm ivh openipmi rpm Note The kernel driver will be compiled using the kernel source code during installation Install IPMItool IPMItool is the command line interface CLI server management client a If the installed Linux distribution uses the 32 bit i386 architecture run the following command rpm ivh ipmitool i386 rpm a If the installed Linux distribution uses the 64 bit x86_64 architecture run the following command rpm ivh ipmitool x86 64 rpm Test the IPMI kernel device driver and client application by running the following command ipmitool I open chassis status Successful output should look similar to the following System Power on Power Overload false Power Interlock inactive Main Power Fault false Power Control Fault false Power Restore Policy unknown Last Power Event Chassis Intrusion inactive Front Panel Lockout inactive Drive Fault false Cooling Fan Fault false n Note On a subsequent reboot the IPMI kernel driver may have to be loaded with the following command modprobe ipmi_kcs_drv Note If you upgrade your Linux kernel refer to Upgrading the Linux Kernel on page 19 Chapter 1 Introduction 15
127. n forced Results in a hard power off This option is ignored b bios Allows you to reflash the BIOS image q quiet Suppresses interative warning messages No error messages are blocked w nowait If specified the command returns immediately instead of waiting for the operation to complete Return Codes TABLE F 17 lists the return codes for this subcommand TABLE F 17 Return Codes for Subcommand platform set os state boot Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation NWSE_Busy 9 Device or resource is busy NWSE_InvalidOpForState 22 Invalid operation for current state 146 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Platform Power State Subcommands The subcommands listed in TABLE F 18 allow you to manage the platform power TABLE F 18 Platform Power State Subcommands Subcommand Description platform get power state Provides the ability to determine the platform power state for example whether it is on or off platform set power state Provide
128. n a script However there are equivalent less destructive commands available This command does not notify the platform OS of the request through the supplied channels Format Command format platform set power state W nowait f forced t timeout TIME off on cycle 148 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE F 20 lists the arguments for this subcommand TABLE F 20 Arguments for Subcommand platform set power state Arguments Description W nowait If specified the command returns immediately instead of waiting for the operation to complete forced Results in a hard power off t timeout Specifies the maximum time to wait for the operation to complete in seconds off on cycle Specifies whether to turn the platform power on or off or to cycle Specifying the cycle argument causes platform power to be turned off then on The subcommand platform set power state does not affect the platform if the platform is already on if the platform is off it powers on and boots the OS In other words the subcommand platform set power state ensures that the platform is on but does not reboot it if it is not on The subcommand platform set os state waits for the platform to boot the subcommand platform set power state only waits for the power to come on Return Codes TABLE F 21 lists the return codes for this subcommand TABLE F 21 Return
129. n also add a public key for SSH authentication allowing you to log in via SSH and execute remote commands without being prompted for a password Refer to Adding Public Keys on page 58 3 Configure your client for scripting You must configure the client machine on which you will be running scripts 4 Create your scripts Remote Scripting Using SSH Remote scripting to the SP is done by using a program called SSH For example as a user on the UNIX machine client company com with the SP name sp company com you could execute a command on the SP from the UNIX client using the following format ssh sp company com command Because the SSH server must authenticate the remote user the user must either enter a password or a trusted host relationship must exist or the remote user s public key must be installed on the SP 56 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 If using trusted host relationships for passwordless access the SP must have a local user of the same name as the remote user or the remote user should be a member of a directory service group that is mapped to a local SP administrative group You can also add your public key file instead of creating a trusted host relationship to be authenticated via SSH Refer to Adding Public Keys on page 58 When configured for passwordless access the ssh daemon on the SP allows the remote user access to sp company com without a pass
130. n the system Resets the platform if unable to access HDT mode The register name address and data are logged to a file For example the information for CPUO is shown in TABLE H 51 TABLE H 51 Sample Information for Subcommand sp get tdulog on CPUO Reg Name Reg Addr Reg Data MSR_MCG_CAP_MSR 0xc0020179 0x0000000000000105 MSR_MCG_STAT_MSR 0xc002017a 0x0000000000000000 MSR_MCG_CTL_MSR 0xc002017b 0x000000000000001F MSR_MCO_CTL 0xc0020400 0x000000000000007F 196 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 52 lists the return codes for this subcommand TABLE H 52 Return Codes for Subcommand sp get tdulog Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NotFound 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_MissingArgument 7 Missing argument s NWSE_UnknownError 15 Miscellaneous error not captured by other errors NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_NotMounted 21 File system is not mounted NWSE_ServiceNotAvailable 24 Requested service is not available SP Reboot Subcommand Description Restarts the SP This command is useful in emergency situations in which you may not have physical access to a m
131. nable to connect to the RPC server Appendix H Service Processor Commands 207 SP Get SMTP Subscribers Subcommand Description Returns detailed information about one or all SMTP subscribers Format Command format sp get smtp subscribers n name lt NAME gt H noheader D delim lt DELIMITER gt TABLE H 69 lists the arguments for this subcommand TABLE H 70 lists the default SMTP subscribers TABLE H 69 Arguments for Subcommand sp get smtp sebscribers Arguments Description n namserver Specifies the name of the SMTP subscriber for which to retrieve information If you do not specify this option the command returns information for all subscribers H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string TABLE H 70 Default SMTP Subscribers Subscriber Description SMTP_Info_Short Short email message informational severity SMTP_Info_Long Long email message informational severity SMTP_Warning_Short Short email message warning severity SMTP_Warning_Long Long email message warning severity SMTP_Critical_Short Short email message critical severity SMTP_Critical_Long Long email message critical severity Long email messages contain full event details in the message body while short email messages contain no messa
132. nd Description sp get smtp server sp get smtp subscribers sp set smtp server sp update smtp subscriber Retrieves the SMTP server information Returns detailed information about one or all SMTP subscribers Configures the SP SMTP client with the address for the remote SMTP server Updates the information for an existing SMTP subscriber SP Get SMTP Server Subcommand Description Retrieves the SMTP server information including the from address Format Command format sp get smtp server H noheader D delim lt DELIMITER gt Appendix H Service Processor Commands 205 TABLE H 65 lists the arguments for this subcommand TABLE H 65 Arguments for Subcommand sp get smtp server Argument Description H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE H 66 lists the return codes for this subcommand TABLE H 66 Return Codes for Subcommand sp get smtp server Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unab
133. nd Sun Fire V40z servers include a dedicated chipset for complete operating system independence and maximum availability of server management functions This chipset called Service Processor SP is an embedded PowerPC chip providing the following m Environmental monitoring of the platform such as temperatures voltages fan speeds and panel switches m Alert messages when problems occur m Remote control of server operations boot shutdown and reboot of the server s operating system turning the server s power on and off stopping the server s boot process in BIOS and upgrading the BIOS Note In this document you might see references to a Baseboard Management Controller BMC A BMC is a dedicated IPMI controller The SP found in these servers is a general purpose embedded CPU that contains software to emulate a BMC Server Management Interfaces These servers include local and remote server management capabilities through the SP the SP supports four server management interfaces a IPMI using a Keyboard Controller Style KCS interface and an IPMI kernel driver in band a IPMI over local area network LAN out of band SNMP integration with third party SNMP management consoles Command line interface CLI LOM Chapter 1 Introduction 3 Command Line Interface Server management capabilities are available from the command line See Appendix B for a list of server management commands that you can use with these
134. nds 215 SP Get SNMP Proxy Community Subcommand Description Returns the community name the SP is currently using to proxy the platform SNMP agent Format Command format sp get snmp proxy community Return Codes TABLE H 81 lists the return codes for this subcommand TABLE H 81 Return Codes for Subcommand sp get snmp proxy community Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server SP Set SNMP Proxy Community Subcommand Description The SNMP agent on the SP acts as a proxy for the master SNMP agent running on the platform These proxy entries specify the OID to be referred the IP address to which they are referred and the community string to use while proxying The community string is the value configured on the platform side SNMP configuration Format Command format sp set snmp proxy community COMMUNITY STRING 216 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 82 lists the argument for this subcommand TABLE H 82 Argument for Subcommand sp set snmp proxy community Argument Description COMMUNITY STRING Specifies the name o
135. ng Return Codes TABLE G 3 lists the arguments for this subcommand TABLEG 3 Return Codes for Subcommand sensor get Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation 156 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Note There are some sensors whose value does not change some that are there to provide information in the event of a problem and others to facilitate the proper operation of the software Many of these sensors do not have a related component parent associated with them For example the die temperature sensor for a CPU has the CPU as its parent component and a fan speed sensor has the fan as its parent component the product id sensor however only reports a static value and has no parent relationship This relationship establishes the component s which is affected by changes in the value of the sensor You cannot modify the threshol
136. ng entry Host HostbasedAuthentication yes Enabling SSH Access Using Public Keys Follow these steps to install public keys to enable SSH access 1 Set up your host keys Refer to Generating a Host Key Pair on page 59 2 Install your public key using the access add public key command 3 Run the following command ssh keygen t rsa N This command generates ssh id_dsa and ssh id_dsa pub 4 Run the following command scp ssh id_rsa pub SP IP tmp Enter your password when prompted 5 Run the following command ssh SP_IP access add public key k tmp id_rsa pub Enter your password when prompted 6 Run the following command ssh SP_IP rm tmp id_rsa pub From this point you have access without requiring a password 60 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Guidelines for Writing Server Management Command Scripts This section describes some basic guidelines for managing your systems by writing scripts for remote execution on one or more SPs Shell Scripts You should be familiar with standard shell scripting Refer to Using Shell Scripts on page 56 SSH You must currently use an SSH Secure Shell client to execute automated command scripts Refer to Remote Scripting Using SSH on page 56 Authentication To avoid being prompted each time you run a script on an SP upload a public key or trusted host key to each SP Refer to Creating Trust
137. nner as you did for the IP address and the subnet mask When finished use the Enter button combination to save the default gateway The LCD displays the following confirmation prompt Use new IP data Yes 11 Press the Select operator panel button to use the new data or use the Cancel button combination to disregard The SP address is now configured and the server is ready for use Note A prompt appears that asks if you want to perform autoconfiguration As an alternative to configuring an SP manually you can run autoconfiguration which replicates the configuration of one SP to another Refer to Autoconfiguring the SP Optional Method on page 24 for instructions on autoconfiguration 12 Continue with Part Il Securing the Service Processor on page 13 12 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Part II Securing the Service Processor After you install the server and configure the SP you must create the initial manager account to secure and access the server You can then perform initial configuration of the server and create additional user accounts Creating the Initial Manager Account A setup account is included with each server This setup account has no password When you log in to the SP the first time using the setup account you are prompted to define the initial manager account with a password and an optional public key Log in to the setup account and create t
138. not have been serviced by the server NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 14 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down 200 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Mount Subcommands The subcommands in TABLE H 57 manage the SP mount points TABLE H 57 SP Mount Subcommands Subcommand Description sp add mount Creates or resets a mount point sp delete mount Deletes the specified mount point sp get mounts Displays the current mount points on the SP SP Add Mount Subcommand Description Creates or resets a mount point Format Command format sp add mount 1 local MOUNTPOINT r remote SERVER FILESYSTEM u user USER p password PASSWORD TABLE H 58 lists the arguments for this subcommand TABLE H 58 Arguments for Subcommand sp add mount Argument Description 1 local Optional Specifies the local mount point The only mount point supported is mnt r remote Specifies the remote server and file system If SERVER specifies a host name DNS must be properly configured u user Specifies the user name for the mount Only required for SMB p password Specifie
139. nowait option in which case the reboot occurs immediately Format Command format sp reset to default settings a all c config n network s ssh u users W nowait 198 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 55 lists the arguments for this command TABLE H 55 Arguments for Subcommand sp reset Argument a all c config n network s ssh u users w nowait Description Resets all SP settings to their default configuration When the SP reboots the settings are reset to their default values Resets other system configuration settings to their default configuration When the SP reboots the system settings are reset to their default values Resets network settings to their default configuration When the SP reboots it has no network capabilities or host name Its NFS mounts fail and you cannot log into the SP remotely through ssh Set up the network configuration for the SP through the operator panel to restore network functions Set the host name for the SP in order to refer to the SP by name and set up the file resolv conf in order to refer to other systems by name instead of by dot quad IP addresses This option deletes all the network files in the directory pstore Resets SSH settings to their default configuration When the SP reboots new ssh public and private keys are generated Usin
140. nsible for performing the management functions requested by the management stations SNMP is used to communicate management information between the management stations and the agents In other words SNMP is the protocol by which the agent and the management station communicate The monitoring of state through SNMP at any significant level of detail is accomplished primarily by polling for appropriate information on the part of the management station Managed nodes may also provide unsolicited status information to management stations in the form of traps which is likely to guide the polling at the management station Communication of information between management entities in a network is accomplished through the exchange of SNMP protocol messages both in the form of queries get set by the management station and in the form of unsolicited messages traps indicated by the agent Your server includes SNMP agents that allow for health and status monitoring The SNMP agent runs on the SP and therefore all SNMP based management of the server should occur through the SP The SNMP agent on these servers provides the following capabilities Event management Inventory management Sensor and system state monitoring SP configuration monitoring SNMP Management Information Base MIB The Management Information Base MIB is a text file that describes SNMP data as managed objects These servers provide SNMP MIBs so that you can manage and monit
141. nt Guide May 2004 TABLE H 44 BIOS POST Codes POST Code Description 48 Check video configuration against CMOS 49 Initialize PCI bus and devices 4A Initialize all video adapters in system 4B QuietBoot start optional 4c Shadow video BIOS ROM 4E Display BIOS copyright notice AF Initialize MultiBoot 50 Display CPU type and speed 51 Initialize EISA board 52 Test keyboard 54 Set key click if enabled 55 Enable USB devices 58 Test for unexpected interrupts 59 Initialize POST display service 5A Display prompt Press F2 to enter SETUP 5B Disable CPU cache 5C Test RAM between 512KB and 640KB 60 Test extended memory 62 Test extended memory address lines 64 Jump to UserPatch1 66 Configure advanced cache registers 67 Initialize Multi Processor APIC 68 Enable external and CPU caches 69 Setup system management mode SMM area 6A Display external L2 cache size 6B Load custom defaults optional 6C Display shadow area message 6E Display possible high address for UMB recovery 70 Display error messages 72 Check for configuration errors Appendix H Service Processor Commands 189 TABLE H 44 BIOS POST Codes POST Code Description 76 7C 7D 7E 80 81 82 83 84 85 86 87 88 89 8A 8B 8c 8F 90 91 92 93 95 96 97 98 99 9A 9c 9D Check for keyboard errors Set up hardware interrupt vectors Initialize Intelligent System Monitoring Initialize coprocessor if present Disable onboard
142. nvalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_DeviceError 25 Unable to read or write to the device Appendix F Platform Commands 141 Platform OS State Subcommands The subcommands listed in TABLE F 12 allow you to manage the operating system OS TABLE F 12 Platform OS State Subcommands Subcommand Description platform get os state Retrieves the current state of the platform OS for example running booting off and so on platform set os state Reboots the platform into the default OS BIOS setup or BIOS update or shuts down the platform platform set os state boot Serves as an alias for the subcommand platform set os state reboot and only functions when the platform power state is off The subcommand platform set os state reboot causes the platform to turn on and boot the OS if the platform is off but reboots the OS if the platform is on The subcommand platform set os state waits for the platform to boot the subcommand platform set power state only waits for the power to come on Platform Get OS State Subcommand Description Retrieves the current state of the platform OS Format Command format platform get os state The values for the current state include Off On Communicating Diagnostics Sleeping BIOS booting BIOS setup OS booting 142 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 m OS
143. oPermission 6 Not authorized to perform this operation Appendix F Platform Commands 139 Platform Set Console Description Enables the configuration of SP access to the platform serial console sets the speed of the connection and limits the size of the log files created Format Command format platform set console serial s platform This option configures the external serial port so that it is connected to the platform serial console This is the default setting platform set console serial s sp enable e disable d prune p noprune n speed s 1200 2400 4800 9600 19200 38400 115200 log 1 size This option configures the external serial port so that it is connected to the SP serial console You can then access the platform serial console through the SP command line by running the subcommand platform console TABLE F 10 lists the arguments for this subcommand Note If s is set to platform none of the following arguments can be used TABLE F 10 Arguments for Subcommand platform set console Arguments Description S speed 1200 Select the port speed for the platform console BIOS the 2400 4800 9600 19200 platform OS and the console must all be configured for the 38400 115200 same speed d disable Indicates that the platform console monitor is inactive Cannot be used with e e enable Indicates that the platform console monitor
144. of the server diagnostics logs Offline location of the log files for the SP scripts Sample scripts that can be used for scripting commands snmp SNMP MIBS Refer to the Sun Fire V20z and Sun Fire V40z Servers Server Management Guide for details spupdate The server for updating the SP Refer to the Sun Fire V20z and Sun Fire V40z Servers Server Management Guide for details sw_images Contains a directory hierarchy of OS specific drivers and files Chapter 4 Further Management Information 69 Serial Over LAN The Serial Over LAN SOL feature lets servers transparently redirect the serial character stream from the baseboard Universal Asynchronous Receiver Transmitter UART to and from the remote client system over LAN Serial over LAN has the following benefits compared to a serial interface m Eliminates the need for a serial concentrator m Reduces the amount of cabling a Allows remote management of servers without video mouse or keyboard headless servers Serial over LAN requires a properly configured LAN connection and a console from which an ssh session can be established In a Linux environment you can use a shell such as csh or ksh as your console This console works well in a scripting environment in which you might want to monitor many servers Enabling or Disabling the SOL Feature on the Server Note When the SOL feature is enabled you cannot access the server through the external DB9 serial port
145. ommand sp get port80 Argument Description m monitor Allows for continuous monitoring of the port 80 traffic You can also retrieve the last ten Port 80 post codes using the operator panel For more details about using the operator panel menus refer to the Sun Fire V20z Server User Guide 817 5248 xx See TABLE H 44 for a list of the Power On Self Test POST codes for the Phoenix BIOS See TABLE H 45 for a list of the boot block codes on Flash ROM 186 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 43 lists the return codes for this subcommand TABLE H 43 Return Codes for Subcommand sp get port80 Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_ServiceNotAvailable 24 Requested service is not available BIOS POST Codes TABLE H 44 lists the POST codes for the Phoenix BIOS TABLE H 44 BIOS POST Codes POST Code Description 02 Verify real mode 03 Disable non maskable interrupt NMI 04 Get CPU type 06 Initialize system hardware 07 Disable shadow and execute code from the ROM 08 Initialize chipset with initial POST values 09 Set IN POST flag OA Initialize CPU registers 0B Enable CPU cache oc Initialize caches to initi
146. or your server using any SNMP capable network management system such as HP OpenView Network Node Manager NNM Tivoli CA Unicenter IBM Director and so on The MIB data describes the information being managed reflects current and recent server status and provides server statistics 42 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Sun Fire V20z and Sun Fire V40z Servers MIB Tree FIGURE 3 1 illustrates the MIB tree STE ccitt iso A S org dod E G internet CA directory mgmt CA experimental private A enterprises E ga newisys 3 6 mibs nsserver serviceprocessor spinventory H E spSST G platformGroup spE vent G spGroup Ca platform CA security E snmp 2 FIGURE 3 1 MIB Tree Integrating MIBs with Third Party Consoles You use the server s MIBs to integrate the management and monitoring of the server into SNMP management consoles The MIB branch is a private enterprise MIB located at object identifier OID 1 3 6 1 2 1 9237 The standard SNMP port 161 is used by the SNMP agent on the SP Chapter 3 SNMP Server Management 43 Configuring SNMP on Your Server Note There are several services that are supplied by the SNMP agent on the server Depending on your business needs and the configuration of your current office network an
147. orm to enable and run the platform console Check or set the BIOS settings Run the command platform set console s sp S 19200 e Run the command platform set console Return Codes TABLE F 6 lists the return codes for this subcommand TABLE F 6 Return Codes for Subcommand platform console Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified Appendix F Platform Commands 137 Platform Get Console Subcommand Description Retrieves the configuration information regarding the Service Processor SP access to the platform serial console Format Command format platform get console H noheader D delim lt DELIMITER gt TABLE F 7 lists the arguments for this subcommand TABLE F 7 Arguments for Subcommand platform get console Arguments Description H noheader Suppresses column headers D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string The following output displays when successful Rear Panel Enabled Speed Pruning Log Trigger SP Console Yes 115200 No 1024KB or Platform COMA No 19200 Yes 64KB One of the other lines of data displays depending on whether the rear panel serial port is connected to the platform or to the SP See TABLE F 8
148. ory get hardware D awk F PRS print 7 awk print 4 inventory get hardware D awk F PRS print 6 You can also obtain this information by running the sensor get command Return Codes TABLE D 5 lists the return codes for this subcommand TABLE D 5 Return Codes for Subcommand inventory get hardware Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server 120 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Inventory Get Software Subcommand Description Returns the inventory information for all installed or uninstalled software located on the optional external file system Format Command format inventory get software a all H noheader D delim lt DELIMITER gt TABLE D 6 lists the arguments for this subcommand TABLE D 6 Arguments for Subcommand inventory get software Arguments Description a all Optional Looks in the directory sw_images on the Service Processor for software packages and uninstalled software H noheader Suppresses column headings D delim Delimits
149. ou only specify the r option for an existing subscriber the existing email address list is replaced with the new list specified in the command TABLE H 72 Arguments for Subcommand sp update smtp subscriber Arguments Description n name Specifies the name of the SMTP subscriber to update This argument is repeatable to update multiple SMTP subscribers at one time r recipients Specifies the address list of recipients for the SMTP subscriber TABLE H 73 Default SMTP Subscribers Subscriber Description SMTP_Info_Short Short email message informational severity SMTP_Info_Long Long email message informational severity SMTP_Warning_Short Short email message warning severity SMTP_Warning_Long Long email message warning severity SMTP_Critical_Short Short email message critical severity SMTP_Critical_Long Long email message critical severity Long email messages contain full event details in the message body while short email messages contain no message body and a descriptive subject line the same subject as used for long messages The short email format is intended to be used with pagers and other wireless access devices with which message size constraints may prevent reception of the long format message 210 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 74 lists the return codes for this command TABLE H 74 Return Codes for Subcommand sp
150. parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_FileError 18 File open file missing or a read or write error occurred 164 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP DNS Subcommands The subcommands in TABLE H 6 manage the DNS configuration on the SP TABLEH 6 SP DNS Subcommands Subcommand Description sp disable dns Disables the DNS configuration on the SP sp enable dns Configures the DNS configuration on the SP sp get dns Displays the current DNS configuration on the SP SP Disable DNS Subcommand Description Disables the DNS configuration on the SP sp disable dns When the SP is configured to use Dynamic Host Control Protocol DHCP DHCP automatically configures DNS settings Changes to the DNS settings in this configuration can be replaced with the DHCP client Return Codes TABLE H 7 lists the return codes for this command TABLEH 7 Return Codes for Subcommand sp disable dns Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced b
151. ple users at one time a all Removes all user accounts The manager level user executing the command is not removed q quiet If the user to delete is not found this argument specifies that no error be returned Return Codes TABLE B 35 lists the return codes for this subcommand TABLE B 35 Return Codes for Subcommand access delete user Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage HE Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NotFound 5 Specified user was not found NWSE_NoPermission 6 Not authorized to perform this operation 102 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Access Get Users Subcommand Description Retrieves all the local users in an administrative group Format Command format access get users g group H noheader D delim lt DELIMITER gt TABLE B 36 lists the arguments for this subcommand TABLE B 36 Arguments for Subcommand access get users Argument Description g group Specifies that group from which to retrieve all users H noheader Specifies that column headings should be suppressed
152. port80 186 get smtp server 205 ssh command protocol 74 SSH using for remote scripting 56 summary of command types 75 system event log IPMI 38 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 T traps server events with SNMP 48 troubleshooting dump utility TDU 195 troubleshooting IPMI 39 troubleshooting SNMP 53 trusted host relationship scripting 58 types of users defined 8 U updating service processor software 21 updating SP base component 23 user groups defined 8 user types defined 8 Index 231 232 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004
153. pt appears with the default response SP use DHCP No 5 Press the Forward button to change to Yes then press the Select button 6 Press the Select button at the confirmation prompt SP use DHCP Yes The server attempts to contact a DHCP server for an IP address Once a DHCP server is contacted the LCD panel displays the default SP settings The SP address is configured and the server is ready for use 7 Continue with Part II Securing the Service Processor on page 13 for instructions on creating the initial manager account Note A prompt appears that asks if you want to perform autoconfiguration As an alternative to configuring an SP manually you can run autoconfiguration which replicates the configuration of one SP to another Refer to Autoconfiguring the SP Optional Method on page 24for instructions on autoconfiguration 10 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Assigning Static SP Network Settings Follow these steps to set the SP network settings using a static IP address You must specify a subnet mask and default gateway This example uses the following sample settings IP Address 192 168 1 2 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 254 Press any operator panel button on the server front panel see FIGURE 1 4 The LCD panel displays the first menu option Menu Server Menu Press the Forward operator panel button until you reach the
154. r Specifies the name of the new user to add This argument is repeatable to add multiple users at one time 100 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 33 lists the return codes for this subcommand TABLE B 33 Return Codes for Subcommand access add user Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid The group specified with g is an invalid local SP administrative group or the length of the user name or password exceeds the maximum length NWSE_NoPermission 6 Not authorized to perform this operation NWSE_Exist 19 The user already exists Access Delete User Subcommand Description Deletes a user Format Command format access delete user USERNAME a all q quiet Appendix B Access Commands 101 TABLE B 34 lists the arguments for this subcommand TABLE B 34 Arguments for Subcommand access delete user Argument Description USERNAME Specifies the name of the user to remove This argument is repeatable to remove multi
155. r Subcommand sp update flash applications Argument Description filename Specifies the full path of the file Return Codes TABLE H 95 lists the return codes for this subcommand TABLE H 95 Return Codes for Subcommand sp update flash applications Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_DeviceError 25 Unable to read or write to the device 224 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Update Flash PIC Subcommand Description This command updates the PIC firmware to a newer version An input PIC update image file is provided Format Command format sp update flash pic f filename FULL PATH OF THE FILE v version TABLE H 96 lists the arguments for this subcommand TABLE H 96 Arguments for Subcommand sp update flash pic Argument Description filename Specifies the full path of the file v version Outputs the current version of the firmware Return Codes TABLE H 97 lists the return codes for this subcommand TABLE H 97 Return
156. r get Returns all data associated with a sensor sensor set Sets some of the data associated with a specific sensor or a class of sensors Note Every command returns a return code upon completion Note There are some sensors whose value does not change some that are there to provide information in the event of a problem and others to facilitate the proper operation of the software Many of these sensors do not have a related component parent associated with them For example the die temperature sensor for a CPU has the CPU as its parent component and a fan speed sensor has the fan as its parent component the product id sensor however only reports a static value and has no parent relationship This relationship establishes the component s which is affected by changes in the value of the sensor You cannot modify the thresholds for sensors without a parent relationship since an event will never occur for these threshold crossings 153 Sensor Get Subcommand Description Returns all data associated with a sensor By default only the sensor ID and its current value are displayed You can specify on the command line the order of the data output Note The identifier field is always displayed first unless you suppress it with the I option Format Command format sensor get i id ID t type TYPE_ID v value n nominal c crithigh c critlow W
157. r this subcommand TABLE H 21 Return Codes for Subcommand sp set hostname Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down Appendix H Service Processor Commands 173 SP IP Subcommands The subcommands in TABLE H 22 manage the SP network configuration TABLE H 22 SP IP Subcommands Subcommand Description sp get ip Retrieves the ethernet based network configuration information for the SP sp set ip Sets or modifies the SP network configuration SP Get IP Subcommand Description Retrieves the ethernet based network configuration information for the SP including IP address network mask and gateway In addition it indicates whether the SP is configured to use DHCP or a static IP address Format Command format sp get ip H noheader D delim lt DELIMITER gt TABLE H 23 lists the arguments for this subcommand TABLE H 23 Arguments for Subcommand sp get ip Argument Description
158. r this subcommand TABLEH 37 Return Codes for Subcommand sp get logfile Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage ik Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoMemory 8 Insufficient memory SP Set Logfile Subcommand Description Configures the event log file that is the destination of all Event Manager events and notices Format Command format sp set logfile f file FILENAME s size SIZE You must specify the name of the file to which the Event Manager sends logs When setting the log file using this command specify only the name of the log file without the path File names cannot contain the forward slash character backward relative path reference or the less than symbol lt TABLE H 38 lists the arguments for this subcommand TABLE H 38 Arguments for Subcommand sp set logfile Argument Description file Specifies the name of the file within the directory to which the Event Manager sends logs s size Specifies the size of the file in megabytes A minimum size of 0 01 MB is required for this log file Appendix H Service Processor Commands 183 Re
159. repare boot BA Initialize DMI parameters BB Initialize PnP option ROMs BC Clear parity checkers BD Display multiboot menu BE Clear screen BF Check virus and backup reminders co Try to boot with interrupt 19 c1 Initialize POST Error Manager PEM c2 Initialize error logging C3 Initialize error display function c4 Initialize system error handler C5 PnP dual CMOS optional c6 Initialize notebook docking optional Appendix H Service Processor Commands 191 TABLE H 44 BIOS POST Codes POST Code Description C7 c8 C9 CA CB cc CD D2 Initialize notebook docking late Force check optional Extended checksum optional Redirect Int 15h to enable remote keyboard Redirect Int 13 to Memory Technologies Devices such as ROM RAM PCMCIA and serial disk Redirect Int 10h to enable remote serial video Re map I O and memory for PCMCIA Initialize digitizer and display message Unknown interrupt Boot Block Codes for Flash ROM TABLE H 45 lists the boot block codes in Flash ROM TABLE H 45 Boot Block Codes in Flash ROM Post Code Description EO El E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED Initialize the chipset Initialize the bridge Initialize the CPU Initialize the system timer Initialize system I O Check force recovery boot Checksum BIOS ROM Go to BIOS Set Huge Segment Initialize Multi Processor Initialize OEM special code Initialize PIC and DMA Initialize Memory typ
160. ressed The delimiter can be any character or string Return Codes TABLE D 9 lists the return codes for this subcommand TABLE D 9 Return Codes for Subcommand inventory get all Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server 122 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX E IPMI Commands The ipmi command manages the Intelligent Platform Management Interface IPMI functions TABLE E 1 lists the groups of ipmi subcommands TABLEE 1 IPMI Subommands Groups Subcommand Description ipmi disable channel Disables one of two IPMI channels ipmi ipmi ipmi ipmi ipmi ipmi ipmi enable channel get channels enable pef disable pef get global enables set global enable reset Enables one of two IPMI channels Displays the list of IPMI channels and whether they are enabled or disabled Enables platform event filtering Disables platform event filtering Displays the list of IPMI global enables and their current value Enables one of two IPMI channels Resets IPMI information back to default factory s
161. rguments were incorrect or invalid NWSE_NotFound 5 Entity user service file path etc was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_InvalidOpForState 22 Invalid operation for current state Access Get Services Subcommand Description Returns a string containing the current naming services option NIS or ADS Format Command format access get services t type nis d domain s server H noheader D delim lt DELIMITER gt access get services t type ads d domain s server 1 logonID o ou H noheader D delim lt DELIMITER gt TABLE B 17 lists the arguments for this subcommand TABLE B 17 Arguments for Subcommand access get services Argument Description t type Returns information about the configuration of either the NIS or ADS service You must specify t to return a list of enabled services d domain Returns domain information Only one of the parameters d and s are permitted at a time s server Returns server information Only one of the parameters d and s are permitted at a time Appendix B Access Commands 89 TABLE B 17 Arguments for Subcommand access get services Argument Description 1 ID For ADS only Returns the ADS logon ID Only one of the par
162. rk Settings Using DHCP on page 9 a Assigning Static SP Network Settings on page 11 Note As an alternative if no DHCP server or physical access is available you can configure the SP using IPMItool in conjunction with an IPMI kernel driver To configure your server for IPMI perform the correct procedures for your operating system in Enabling IPMI Access on the Server on page 14 then Enabling IPMI LAN Access on page 17 Assigning SP Network Settings Using DHCP The following procedure describes how to set the SP network settings using DHCP from the Operator Panel If your network does not use DHCP or you want to assign a static IP address to the SP follow the instructions in Assigning Static SP Network Settings on page 11 Note This procedure assumes that you have cabled the server and powered it on as described in the Sun Fire V20z and Sun Fire V40z Servers Installation Guide At least of the server s SP ports must be connected to a LAN Press any operator panel button on the server front panel see FIGURE 1 4 The LCD panel displays the first menu option Menu Server Menu Chapter 1 Introduction 9 Press both for Cancel Press both for Enter FIGURE 1 4 Operator Panel Buttons 2 Press the Forward button until you reach the SP menu Menu SP menu 3 Press the Select button to display the SP menu options SP Menu Set SP IP info 4 Press the Select button The following prom
163. rs User 817 5248 xx Diagnostics Guide Release notes and Sun Fire V20z and Sun Fire V40z Servers Release 817 5252 xx updated information Notes xx Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Accessing Sun Documentation You can view print or purchase a broad selection of Sun documentation including localized versions at http www sun com documentation Third Party Web Sites Sun is not responsible for the availability of third party web sites mentioned in this document Sun does not endorse and is not responsible or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content goods or services that are available on or through such sites or resources Contacting Sun Technical Support If you have technical questions about this product that are not answered in this document go to http www sun com service contacting Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun Fire V20z and Sun Fire V40z Servers Server Management Guide part num
164. rsion 2 key types RSA or DSA only If DNS is enabled on the SP the client machine must be specified with its DNS name and not the IP address Generating Host Keys The host s ssh install should generate the host keys If it does not follow these steps to manually generate the key pair 1 Enter the following command ssh keygen q t rsa f rsa_key C N 2 Copy rsa_key to etc ssh ssh_host_rsa_key 3 Ensure that only root has read or write permission to this file The rsa_key pub file is the file you will transfer to the SP Note Only protocol version 2 key types and 1024 bit key sizes the default generated by ssh keygen are supported 4 Copy the host s public key the rsa_key pub file to the SP using scp secure copy or by copying the host key to an external file system that has been mounted on the SP Note Use scp to copy the files to either tmp or to your home directory The sp commands will then install the file specified on the command line to pstore Note If DNS is enabled on the SP you must specify the client that is used in the trust commands with its DNS name and not the IP address 92 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 21 lists the return codes for this subcommand TABLE B 21 Return Codes for Subcommand access add trust Return Code ID Description NWSE_Success 0 Command successfully completed
165. running this command you can immediately run Service Processor tests or wait for the subcommand diags get state to return the result platform diags available at which point you can run platform tests The platform state must be either off or OS Communicating Refer to the subcommand platform get os state for details about these states Format Command format diags start noplatform Arguments Description noplat form Lets you enable diagnostics when the platform power is on and the OS is running Return Codes TABLE C 9 lists the return codes for this subcommand TABLEC 9 Return Codes for Subcommand diags start Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server 114 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLEC 9 Return Codes for Subcommand diags start Return Code ID Description NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_InvalidOpForState 22 Invalid operation for current state Appendix C Diagnostics Commands 115 Diags Term
166. rvice group mapped to one of the standard administrative groups Manages public keys and public key users Enables disables or defines a directory services mechanism that determines a user s group memberships Creates a host based trust relationship for the specified host Manages local users or a group of users Note Every command returns a return code upon completion 79 Access Groups Subcommands The subcommands in TABLE B 2 return the authorization group for a specific user or a list of defined groups TABLE B 2 Access Group Subcommands Subcommand Description access get group Returns the authorization group for the specified user access get groups Returns a list of the groups defined including the standard groups Access Get Group Subcommand Description Returns the authorization group for the specified user Format Command format access get group Return Codes TABLE B 3 lists the return codes for this subcommand TABLE B 3 Return Codes for Subcommand access get group Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5
167. ry for event logs Format Command format sp get hostname f fqdn TABLE H 18 lists the argument for this subcommand TABLE H 18 Argument for Subcommand sp get hostname Argument Description fadn Causes the fully qualified hostname to display Appendix H Service Processor Commands 171 Return Codes TABLE H 19 lists the return codes for this subcommand TABLE H 19 Return Codes for Subcommand sp get hostname Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down SP Set Hostname Subcommand Description Resets the host name or domain name of the SP to the specified name This name is used by many of the networking programs to identify the machine Format Command format sp set hostname HOSTNAME TABLE H 20 lists the argument for this subcommand TABLE H 20 Argument for Subcommand sp set hostname Argument Description T HOSTNAME Specifies the name of the host to set 172 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 21 lists the return codes fo
168. s Subcommand Description access add public key Installs a public key for SSH authentication access get public key users Determines which users have public keys installed access delete public key Removes a user s public key Access Add Public Key Subcommand Description Installs a public key for SSH authentication which enables SSH logins and remote command execution without being prompted for a password You must first generate a key pair RSA or DSA which you can generate using the ssh keygen command included with OpenSSH m Only local users can install public keys not users who gain authorization through a mapping of a directory services group a Managers can add keys for any local user a Up to 10 users can install public keys one key per user a The maximum key length supported is 4096 bits Format Command format access add public key k keyfile PUBLIC_KEY_FILE u user USER TABLE B 26 lists the arguments for this subcommand TABLE B 26 Arguments for Subcommand access add public key Arguments Description k keyfile Specifies the user s public RSA or DSA key u user Specifies the user for which this key will be installed The default is the current user if no user is specified 96 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 27 lists the return codes for this subcommand TABLE B 27 Return Codes for Subcommand acces
169. s f forced START STOP platform set os state shutdown w nowait f forced q quiet platform set os state update bios q quiet w nowait BIOS_IMAGE TABLE F 14 lists the arguments for this subcommand TABLE F 14 Arguments for Subcommand platform set os state Arguments Description w nowait If specified the subcommand returns immediately instead of waiting for the operation to complete forced Results in a hard power off b bios Only applicable to the subcommand platform set os state reboot Takes you to the BIOS Setup utility q quiet Suppresses interative warning messages No error messages are blocked update bios Command option for flash updating the BIOS image BIOS_IMAGE Only applicable to the subcommand set os state update bios Indicates the name of the file containing the new BIOS image to use when updating the BIOS The subcommand platform set os state waits for the platform to boot the subcommand platform set power state only waits for the power to come on The subcommand platform set os state reboot causes the platform to turn on and boot the OS if the platform is off but reboots the OS if the platform is on 144 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 When the platform is in the Communicating state in which the OS is communicating with the SP if the platform drivers are uninstalled the
170. s The subcommands in TABLE H 12 manage events on the SP TABLE H 12 SP Events Subcommands Subcommand Description sp delete event Clears an existing event using the event ID sp get events Returns detailed information about all active SP events SP Delete Event Subcommand Description Clears an existing event using the event ID Format Command format sp delete event EVENT ID a all q quiet TABLE H 13 lists the arguments for this subcommand TABLEH 13 Arguments for Subcommand sp delete event Argument Description EVENT ID Specifies the existing event to clear This argument is repeatable to clear multiple events at one time a all Removes all events q quiet If the event to delete is not found this argument specifies that no error be returned 168 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 14 lists the return codes for this subcommand TABLE H 14 Return Codes for Subcommand sp delete event Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5 Entity user
171. s 126 IPMI Disable PEF Subcommand 127 Format 127 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes 127 IPMI Enable PEF Subcommand 128 Format 128 Return Codes 128 IPMI Get Global Enables Subcommand 129 Format 129 Return Codes 129 IPMI Set Global Enable Subcommand 130 Format 130 Return Codes 131 IPMI Reset Subcommand 132 Format 132 Return Codes 132 Platform Commands 133 Platform Console Subcommands 134 Platform Console Subcommand 134 Format 134 Return Codes 137 Platform Get Console Subcommand 138 Format 138 Return Codes 139 Platform Set Console 140 Format 140 Return Codes 141 Platform OS State Subcommands 142 Platform Get OS State Subcommand 142 Format 142 Return Codes 143 Contents xi Platform Set OS State Subcommand 144 Format 144 Return Codes 145 Platform Set OS State Boot Subcommand 145 Format 145 Return Codes 146 Platform Power State Subcommands 147 Platform Get Power State Subcommand 147 Format 147 Return Codes 148 Platform Set Power State Subcommand 148 Format 148 Return Codes 149 Platform Get Hostname Subcommand 150 Format 150 Return Codes 150 Platform Get Product ID Subcommand 151 Format 151 Return Codes 151 G Sensor Commands 153 Sensor Get Subcommand 154 Format 154 Return Codes 156 Sensor Set Subcommand 158 Format 158 Return Codes 159 H Service Processor Commands 161 xii Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP
172. s ARPs on off arp interval Sets the interval for the BMC generated gratuitous ARPs seconds s auth level This command sets the valid authtypes for a given auth type level Levels can be callback user operator admin Types can be none md2 md5 fru print Reads all inventory data for the Customer Replaceable Units CRUs and extracts such information as serial number part number asset tags and short strings describing the chassis board or product sdr list Reads the Sensor Data Record SDR and extracts sensor information then queries each sensor and prints its name reading and status sel info Queries the BMC for information about the system event log SEL and its contents clear Clears the contents of the SEL The clear command cannot be undone list Lists the contents of the SEL Chapter 2 IPMI Server Management 35 IPMI Linux Kernel Device Driver The IPMItool application utilizes a modified MontaVista OpenIPMI kernel device driver found on the Sun Fire V20z and Sun Fire V40z Servers Documentation and Support Files CD The driver has been modified to use an alternate base hardware address and modified device IO registration This driver must be compiled and installed from the Documentation and Support Files CD The following kernel modules must be loaded in order for IPMItool to work 1 ipmi_msghandler The message handler for incoming and outgoing messages for the IPMI interfaces 2 ipmi_kcs_drv An I
173. s a BMC The BMC is responsible for m Managing the interface between server management software and platform management hardware m Interfacing to the system sensors such as fan speed and voltage monitors m Providing access to the system event log a Providing autonomous monitoring event logging and recovery control m Acting as a gateway between the management software and the IPMB ICMB Monitoring the system watchdog timer Facilitating the remote management tasks even when the main server hardware is in an inoperable state The BMC provides the intelligence behind IPMI In these servers the SP serves as the BMC providing access to sensor data and events through the standard IPMI interfaces Manageability IPMI defines a mechanism for server monitoring and recovery implemented directly in hardware and firmware IPMI functions are available independent of the main processors BIOS and operating system IPMI monitoring logging and access functions add a built in level of manageability to the platform hardware IPMI can be used in conjunction with server management software running under the OS which provides an enhanced level of manageability IPMI provides the foundation for smarter management of servers by providing a methodology for maintaining and improving the reliability availability and serviceability of expensive server hardware 28 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004
174. s add public key Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid The group specified with g is an invalid local SP administrative group or the length of the username or password exceeds the maximum length NWSE_Not Found 5 Entity user service file path or other was not found NWSE_NoPermission 6 Not authorized to perform this operation NWSE_Exist 19 The user already exists NWSE_LimitExceeded 26 Limit has been exceeded Access Get Public Key Users Subcommand Description Determines which users have public keys installed Format Command format access get public key users Appendix B Access Commands 97 Return Codes TABLE B 28 lists the return codes for this subcommand TABLE B 28 Return Codes for Subcommand access get public key users Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and t
175. s the ability to turn the platform power on or off The subcommand platform set power state does not affect the platform if the platform is already on if the platform is off it powers on and boots the OS In other words the subcommand platform set power state ensures that the platform is on but does not reboot it if it is not on The subcommand platform set os state waits for the platform to boot the subcommand platform set power state only waits for the power to come on Platform Get Power State Subcommand Description Provides the ability to determine the platform power state from within a script whether the platform is on or off Format Command format platform get power state Appendix F Platform Commands 147 Return Codes TABLE F 19 lists the return codes for this subcommand TABLE F 19 Return codes for Subcommand platform get power state Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation Platform Set Power State Subcommand Description Provides the ability to turn the platform power on or off from withi
176. s the password for the mount user Only required for SMB Appendix H Service Processor Commands 201 Note Several error messages may appear when executing an smb mount while mounting windows partitions Check that the mount succeeded after the call by running the subcommand sp get mount The required formats for remote NFS and SMB mounts are as follows m For NFS server_name server_exported_mountpoint m For SMB server_name windows_share_name Return Codes TABLE H 59 lists the return codes for this subcommand TABLE H 59 Return Codes for Subcommand sp add mount Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_Busy 9 Device or resource is busy NWSE_RPCConnected 11 RPC client already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down NWSE_UnknownError 15 Miscellaneous error not captured by other errors 202 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Delete Mount Description Deletes a mount point Format Command format sp delete mount LOCAL_MOUNT_POINT q quiet TABLE H 6
177. sS R SUN microsystems Sun Firem V20z and Sun Fire V40z Servers Server Management Guide Sun Microsystems Inc www sun com Part No 817 5249 11 May 2004 Revision A Submit comments about this document at http www sun com hwdocs feedback Copyright 2004 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to tecnnology fiat is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the SAONE may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Java JumpStart Solaris and Sun Fire are trademarks or registere
178. servers as well as a description the command format a list of arguments and a list of return codes for each command SSH and Scripting Capabilities A system administrator can log in to the Service Processor using SSH and issue commands or more commonly write a shell script that remotely invokes these operations The server management commands enable you to efficiently manage each area of the server From the command line you can write data driven scripts that automate the configuration of multiple machines For example a central management system can cause many servers to power on and boot at a specified time or when a specific condition occurs For more information about scripting see Configuring Scripting Capabilities on page 55 SNMP Integration SNMP management provides remote access by SNMP compliant entities to monitor the health and status of the server The SP sends SNMP alerts to external management functions when warranted For more information about SNMP refer to SNMP Server Management on page 41 The diagram in FIGURE 1 1 illustrates the communications paths for the different server management options 4 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 FIGURE 1 1 Sun Control Station MODULES Health Monitoring Lights Out Management Software Management AllStart and others IPMItool Third Party Management CLI LOM SNMP based solutions HP Open View CA UniCen
179. sole Server Cross over Server External LANs Cross over Zz lt l C D es FIGURE 1 5 Daisy Chain Architecture To interconnect the servers you must use an RJ 45 cross over cable Cables can be connected to either the top or bottom SP port To configure servers in a daisy chain connect the first and last server in the chain to different switches Managed spanning tree capable switches are required to redundantly connect both the top and bottom of the chain If the switch is not capable of spanning tree discovery then only connect either to the top or the bottom of the chain but not both 20 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Site Integration When deploying your server ensure that you determine the best integration strategy for your environment These servers include network connections for the service processor SP that are separate from network connections for the platform This allows you to configure the server so that the SP is connected to an isolated management network and is not accessible from the production network Updating the SP Software Note For complete information about the menu options available through the operator panel refer to the Sun Fire V20z and Sun Fire V40z Servers User Guide If you attempt to update the SP software using the operator panel when the IP address for the SP has not
180. super I O ports and IRQs Late POST device initialization Detect and install external RS232 ports Configure non MCD IDE controllers Detect and install external parallel ports Initialize PC compatible PnP ISA devices Reinitialize onboard I O ports Configure motherboard configurable devices optional Initialize BIOS data area Enable non maskable interrupts NMIs Initialize extended BIOS data area Test and initialize PS 2 mouse Initialize floppy controller Determine number of ATA drives optional Initialize hard disk controllers Initialize local bus hard disk controllers Jump to UserPatch2 Build MPTABLE for multi processor boards Install CD ROM for boot Clear huge ES segment register Fixup multi processor table Search for option ROMs Check for SMART drive optional Shadow option ROMs Set up power management Initialize security engine optional 190 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 44 BIOS POST Codes POST Code Description 9E Enable hardware interrupts 9F Determine number of ATA and SCSI drives AO Set time of day A2 Check key lock A4 Initialize typematic rate A8 Erase F2 prompt AA Scan for F2 key stroke AC Enter setup AE Clear boot flag BO Check for errors B1 Inform RomPilot about the end of POST B2 POST done prepare to boot operating system B4 One short beep B5 Terminate QuietBoot optional B6 Check password B7 Initialize ACPI BIOS B9 P
181. t PORT Note This command includes the optional p flag to denote that the server is running on a port other than the default port This command pings the update server to see if the update server is up and running If successful your connection is closed when the SP reboots and the update process begins Refer to Appendix B for more information about the sp commands Monitor progress of the update process on the server Messages display as the installation process progresses When complete the SP reboots with the new version installed Chapter 1 Introduction 23 Autoconfiguring the SP Optional Method Autoconfiguration replicates the majority of configuration files from an SP that has already been configured to another SP so that the two servers have identical configurations except for the host name and IP address For example after you configure a single SP set up users hosts certificates mounts and so on you then run autoconfiguration on each additional SP so that the settings are identical In addition if you modify the configuration of one SP you can update all of them by re running autoconfiguration on each one For this reason set the IP address of the autoconfigure server to x x x 1 Note Autoconfiguration does not merge configurations it overwrites the existing configuration Note Autoconfiguration does not work across diffrent server platforms That is you cannot configure a Sun Fire
182. t 2004 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propriate intellectuelle relatants la technologie qui est d crite dans ce document En particulier et sans la limitation ces droits de propri t intellectuelle peuvent inclure un ou plus des brevets am ricains num r s a http www sun com patents et un ou les brevets plus suppl mentaires ou les applications de brevet en attente dans les tats Unis et dans les autres pays Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Java JumpStart Solaris et Sun Fire sont des marques de fabrique ou des marques d pos es
183. t 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_HostDown 14 Host is down SP Get Status Subcommand Description Returns the status of the overall system Format Command format sp get status TABLE H 48 lists the arguments for this subcommand TABLE H 48 Arguments for Subcommand sp get status Argument Description Nominal All components are operating within normal parameters Warning One or more components are operating at warning levels Critical One or more components are operating out of specification or have failed 194 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE H 49 lists the return codes for this subcommand TABLE H 49 Return Codes for Subcommand sp get status Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation SP Get TDULog Subcommand Description The Troubleshooting Dump Utility TDU captures debug data When you execute this command this
184. t already connected NWSE_RPCConnRefused 12 RPC connection refused NWSE_NoRouteToHost 13 No route to host network down NWSE_HostDown 14 Host is down 150 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Platform Get Product ID Subcommand Description Displays the product ID for the current system Format Command format platform get product id Note You can also retrieve the product ID board revision number and PRS revision number by running the subcommands sensor get and inventory get hardware Return Codes TABLE F 24 lists the return codes for this subcommand TABLE F 24 Return Codes for Subcommand platform get product id Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_Not Found 5 Entity user service file path or other was not found NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_ServiceNotAvailable 24 Requested service is not available Appendix F Platform Commands 151 152 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 APPENDIX G Sensor Commands The sensor command reports or sets the value of an environmental sensor or control TABLE G 1 lists the groups of sensor subcommands TABLE G 1 Sensor Subcommand Groups Subcommand Group Description senso
185. table 76 S scripts using command output 61 guidelines 61 host key generation 57 host key pair generation 59 multiple system configuration 57 overview 55 public keys adding 58 remote scripting with SSH 56 shell scripts overview 55 SSH access using public keys 60 SSH access using trusted hosts 59 tips for best results 62 trusted host relationship 58 securetty using for console redirection 66 sensor commands get 154 set 158 subcommand summary table 153 serial over LAN feature disabling 71 enabling 70 launching and terminating sessions 71 server management interfaces list 3 server management options diagram 5 server management overview 3 service processor assigning network settings DHCP 9 assigning network settings static 11 autoconfiguration 24 initial setup 9 MAC address 25 securing with accounts 13 SNMP agent 45 updating SP base component 23 Index 229 updating SP software 21 service processor commands see sp commands setup account logging in 13 shell scripts using 55 simple network management protocol see SNMP interface SNMP interface agent on the SP 45 Agent X 46 architecture diagram 44 community name setting 46 configuring 44 integration overview 42 logging options setting 47 management information base MIB 42 MIB details 50 overview 41 prerequisites 44 proxy agent 45 server event trap destinations 49 server event traps 48 SP events table 51 third party MIB browser 47
186. ter etc N 1 _ LOM Pos CE P Platform NICs Le SN l Service ee S NZ Processor NIC Server Platform IPMI management through IPMItool OpenIPMI Linux LIPMI Solaris N 10 100 Mb s Out of band KCS In band Service Processor SP Diagram of the Server Management Options Chapter 1 Introduction Operator Panel You can use the operator panel to configure network settings for the SP See FIGURE 1 2 or FIGURE 1 3 for the operator panel location on your server Note The SP defaults to Dynamic Host Configuration Protocol DHCP networking if the operator panel is not interactively engaged on the first power up Operator panel buttons Operator panel display FIGURE 1 2 Sun Fire V20z Server Operator Panel and Buttons Operator panel displa Operator panel buttons 3 F P si FIGURE 1 3 Sun Fire V40z Server Operator Panel and Buttons 6 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 The operator panel displays information on the LCD display in two lines and you respond to prompts or initiate actions using the following buttons TABLE 1 2 Operator Panel Buttons Buttons Function Back No 19 Select A Forward Yes gt ve Enter rX Cancel 19 d If a menu or data entry screen displays for more than 30 seconds with no action taken the menu or data entry is cancelled and the display returns to t
187. the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server Appendix C Diagnostics Commands 111 TABLEC 6 Return Codes for Subcommand diags get tests Return Code ID Description NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_MissingArgument 7 Missing argument s Diags Run Tests Subcommand Description Submits one or more diagnostic tests for execution Format Command format diags run tests n name TEST NAME a all H noheader P noprogress m module MODULE NAME v verbose TABLE C 7 lists the arguments for this subcommand TABLEC 7 Arguments for Subcommand diags run tests Arguments Description n name Specifies the specific test s to execute Run diags get tests for a list of individual test names a all Specifies that all tests are to be executed Run diags get tests fora list of all available tests Specifying no arguments also runs all tests for each device in the server H noheader Suppresses header output P noprogress Suppresses progress dots when waiting for test results m module Specifies that only tests for the specified module are to be executed Run diags get tests for a list of modules v verbose If spe
188. the date and time on the SP RTC DNS Displays or configures the DNS client configuration on the SP Events Returns detailed information or clears an event Hostname Displays or resets the host name or domain name of the SP IP Sets modifies or retrieves the SP network configuration JNET Address Locate Light Logfile Miscellaneous Mount SMTP Sets or retrieves the jnet address Sets the state or reads the value of the locatelight switch Retrieves or configures the event log file Reads status for a component retrieves the last port 80 postcode restores settings to defaults stores data in tar zipped format or captures debug data Displays creates resets or deletes a mount point Manages information about SMTP email delivery 161 TABLE H 1 Service Processor Subcommand Groups Subcommand Description SNMP Manages SNMP functions SSL Manages SSL capabilities Update Flash Sets the update flag to start the full flash update or copies the Value Add file to the Value Add component of the SP flash SP Date Subcommands The subcommands in TABLE H 2 manage the date and time on the SP TABLEH 2 SP Date Subcommands Subcommand Description sp get date Retrieves the date and time from the SP RTC sp set date Sets the date and time on the SP RTC SP Get Date Subcommand Description Retrieves the date and time from the SP RTC Format Command format sp get date 162 Sun Fire V20z
189. the names of all the site specified groups mapped to a specific administrative group Format Command format access get map H noheader D delim lt DELIMITER gt TABLE B 6 lists the arguments for this subcommand TABLE B 6 Arguments for Subcommand access get map Argument Description H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string To return mappings for all groups omit the group name from the command line 82 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Return Codes TABLE B 7 lists the return codes for this subcommand TABLE B 7 Return Codes for Subcommand access get map Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage i Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid Access Map Subcommand Description Maps an existing site specified group name the directory services group to one of the standard administrative groups Format Command
190. this operation 166 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Get DNS Subcommand Description Displays the current DNS configuration on the SP Format Command format sp get dns n nameserver s searchdomain H noheader D delim lt DELIMITER gt TABLE H 10 lists the arguments for this subcommand TABLE H 10 Arguments for Subcommand sp get dns Argument Description n nameserver Displays the name server s If there is more than one nameserver they print on separate lines s searchdomain Displays the searchdomain s If there is more than one searchdomain they print on separate lines H noheader Suppresses column headings D delim lt DELIMITER gt Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE H 11 lists the return codes for this subcommand TABLE H 11 Return Codes for Subcommand sp get dns Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server Appendix H Service Processor Commands 167 SP Events Subcommand
191. ts Out Management is performed through IPMItool a utility for controlling IPMI enabled devices Description IPMItool is a simple command line interface CLI to servers that support the Intelligent Platform Management Interface IPMI v1 5 specification It provides the ability to Read the Sensor Data Record SDR and print sensor values Display the contents of the System Event Log SEL Print information about Field Replaceable Units FRUs Read and set LAN configuration parameters Perform chassis power control Originally written to take advantage of IPMI over LAN interfaces IPMItool is also capable of using a system interface as provided by a kernel device driver such as OpenIPMI Further Information a For up to date information about IPMItool visit http ipmitool sourceforge net a For more information about the IPMI specification visit http www intel com design servers ipmi spec htm m For more information about the OpenIPMI project MontaVista IPMI kernel driver visit http openipmi sourceforge net Syntax The syntax used by IPMItool is as follows ipmitool ghcvV I lan H address P password expression ipmitool ghcvV I open expression 30 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 Options TABLE 2 1 lists the options available for IPMItool TABLE 2 1 Options for IPMItool Option Description h Provides help on basic usage from the command line
192. turn Codes TABLE H 39 lists the arguments for this subcommand TABLE H 39 Return Codes for Subcommand sp set logfile Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory 184 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Miscellaneous Subcommands The subcommands in TABLE H 40 manage miscellaneous SP functions TABLE H 40 Miscellaneous SP Subcommands Subcommand Description sp create test events Tests and validates different types of configurations you may be considering for the SP sp get port 80 Retrieves the last port 80 postcode from the PRS Port80 register sp get status Returns the status of the overall system sp get tdulog Captures data and stores it on the SP in compressed format sp load settings Configures an SP with the same configuration as that of another Service Processor sp reboot Restarts the SP sp reset Restores selected settings of the SP to the default factory configuration SP Create Test Events Subcommand Description
193. u can access after you extract the files on the CD See Network Share Volume NSV CD ROM on page 68 for more information about the script locations 55 Using Shell Scripts An administrator can make configuration changes for a single SP by using SSH to log in and run commands For a multi system environment in which configurations for all SPs must be synchronized you can automate configuration changes As a Unix Linux administrator you can use SSH trusted host relationships or public key authentication and Unix Linux shell scripting to automate tasks that need to be performed on multiple SPs 1 Set up your system for scripting Sun Fire V20z and Sun Fire V40z remote scripting solutions depend on SSH for authentication and data encryption If you do not already have SSH you can obtain a free implementation OpenSSH available at www openssh org The SP allows the use of SSH v2 only Refer to Remote Scripting Using SSH on page 56 2 Create a trusted host relationship or add your public key for SSH authentication In order to use SSH in a scripted environment such that you are not prompted for a password upon the execution of each command you can establish a trusted host relationship between the machine from which the commands are sent and the SP on which the commands are executed This requires the prior creation of a manager level user on the SP Refer to Creating Trusted Host Relationships on page 58 You ca
194. ubcommands The subcommands in TABLE H 91 manage the SP flash TABLE H 91 SP Flash Subcommands Subcommand Description sp update flash all Sets the update flag to start the full flash update on the next reset of the SP sp update flash applications Copies the file Value Add to the Value Add component of the SP flash sp update flash pic Updates the PIC firmware to a newer version sp update diags Updates the diagnostics to a newer version SP Update Flash All Subcommand Note Before using this command you must start the Java Update Server For instructions on starting Java Update Server see Updating the Service Processor Base Component on page 23 Description Updates the entire SP flash image kernel base file system and value add as part of a major SP software update This command requires the use of the Java Update Server and verifies that it is available before beginning the update process Once verified the SP is rebooted and the update process is initiated When completed the SP is automatically rebooted using the updated image Format Command format sp update flash all i ipaddress lt IP ADDRESS XXX XXX XXX XXX gt p port lt PORT gt 222 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 TABLE H 92 lists the arguments for this subcommand TABLE H 92 Arguments for Subcommand sp update flash all Argument Description i serverip The IP ad
195. ue defined when you configured the platform for SNMP If you find that your SNMP queries are not being proxied to the platform SNMP agents validate that the community string on the SP matches that on the platform The SP proxy community string can be changed to match the platform community string using the following command sp set snmp proxy community There are no restrictions on the length of the community strings common names are private and public The default name is public For more information refer to SP Set SNMP Proxy Community Subcommand on page 109 Agent X A sub agent using SNMP Agent X protocol on the platform can connect to the SNMP agent on the SP through a special port and forward query responses or unsolicited traps through the SP This allows server management traffic to be kept secure from the production network connected to the platform if required To properly enable this facility you must identify the IP address and port number pair associated with the SP as seen from the platform The Agent X port is fixed at 705 TCP However the private network IP address is configurable and by default this address is 169 254 101 2 Refer to your application documentation for instructions on configuring the sub agents Note You can use the subcommand sp get jnet on the SP to retrieve the JNET IP address of the SP 46 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004
196. ued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid NWSE_NoPermission 6 Not authorized to perform this operation NWSE_InvalidOpForState 22 Invalid operation for current state Access Enable Service Subcommand Description Enables a directory service either NIS or ADS to name service lookup system on the SP Format Command format access enable service nis d domain DOMAIN NAME s server SERVER access enable service ads d domain DOMAIN NAME s server SERVER k keytab KEYTAB FILENAME o ou ORGANIZATIONAL UNIT 1 logon LOGON Appendix B Access Commands 87 TABLE B 15 lists the arguments for this subcommand TABLE B 15 Arguments for Subcommand access enable service Argument Description d domain Specifies the domain name s server Specifies the server k keytab For ADS only Specifies the ADS keytab file name o ou For ADS only Specifies the organizational unit under which the name service library looks for group data 1 logon For ADS only Specifies the logon ID for the active directory account To use ADS as a directory service on the SP you must create an active directory account The name service library on the SP uses t
197. ully completed NWSE_InvalidUsage L Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_FileError 18 File open file missing or a read or write error occurred NWSE_ServiceNotAvailable 24 Requested service is not available Appendix H Service Processor Commands 219 SP Get SSL Subcommand Description Determines if automatic redirect to secure HTTP is required or optional and whether Apache Web Server is using factory or user supplied SSL certificate files Format Command format sp get ssl H noheader D delim lt DELIMITER gt TABLE H 87 lists the arguments for this subcommand TABLEH 87 Arguments for Subcommand sp get ssl Arguments Description H noheader Suppresses column headings D delim Delimits columns with the specified delimiter Headings are also delimited unless suppressed The delimiter can be any character or string Return Codes TABLE H 88 lists the return codes for this subcommand TABLE H 88 Return Codes for Subcommand sp get ssl Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_NoPermission 6 Not authorized to perform this operation NWSE_NoMemory 8 Insufficient memory NWSE_ServiceNotAvailable 24 Requested servic
198. update smtp subscriber Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_Not Found 5 Entity user service file path etc was not found NWSE_NoPermission 6 Not authorized to perform this operation Appendix H Service Processor Commands 211 SP SNMP Subcommands The subcommands in TABLE H 75 manage SNMP communications TABLE H 75 SP SNMP Subcommands Subcommand sp add snmp destination sp delete snmp destination sp get snmp destinations sp get snmp proxy community sp set snmp proxy community Description Adds an SNMP destination Deletes the SNMP destination Displays the available SNMP destinations IP address or hostname to which the Service Processor is configured to send Returns the community name currently being used by the Service Processor SNMPD to proxy the platform SNMP agent Sets the proxy entries that specify the OID to be referred the IP to which they are referred and the community string to use while proxying SP Add SNMP Destination Subcommand Description Adds a single SNMP destination either IP address or host name Format
199. witch which represents the state of the front and rear panel identification lights sp set locatelight Sets the state of the locatelight switch SP Get Locatelight Subcommand Description Reads the value of the locatelight switch which represents the state of the front and rear panel identification lights The possible states are blinking or off Format Command format sp get locatelight Return Codes TABLE H 33 lists the return codes for this subcommand TABLE H 33 Return Codes for Subcommand sp get locatelight Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage 1 Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_RPCNotConnected 3 Unable to connect to the RPC server NWSE_NoPermission 6 Not authorized to perform this operation 180 Sun Fire V20z and Sun Fire V40z Servers Server Management Guide May 2004 SP Set Locatelight Subcommand Description Sets the state of the locatelight switch which describes the state of the front and rear panel identification lights Format Command format sp set locatelight blink off Return Codes TABLE H 34 lists the return codes for this subcommand TABLE H 34 Return Codes for Subcommand sp set locatelight Return Code I
200. word either for logging in or for issuing remote ssh commands from the command line or from a script Configuring Multiple Systems for Scripting There are two ways to configure multiple SPs for scripting m Execute the procedure to configure the client machine on which you will be running scripts for each SP m Set up the trust relationship or add your public key file on an initial machine and use the autoconfiguration feature to duplicate the configuration on each of the additional machines Refer to Creating Trusted Host Relationships on page 58 and Adding Public Keys on page 58 Generating Host Keys To establish a trusted host relationship you must set up a host key which is used to authenticate one host to another The host s SSH install should generate the host keys If it does not follow these steps to generate a host key pair Enter the following command ssh keygen q t rsa f rsa key C N Move rsa_key to etc ssh ssh_host_rsa_key Move rsa_key pub to etc ssh ssh_host_rsa_key pub Ensure that only the root user has read or write permissions to etc ssh ssh_host_rsa_key The ssh_host_rsa_key pub file is the file you will transfer to the SP Note Only protocol version 2 key types and 1024 bit key sizes the default generated by ssh keygen are supported Continue with Creating Trusted Host Relationships on page 58 for instructions on creating public keys that can be us
201. xes describe each command type in detail See Server Management Commands Summary on page 73 Appendix B contains detailed descriptions of Access commands See Access Commands on page 79 Appendix C contains detailed descriptions of Diagnostics commands See Diagnostics Commands on page 107 Appendix D contains detailed descriptions of Inventory commands See Inventory Commands on page 117 xix Appendix E contains detailed descriptions of IPMI commands See IPMI Commands on page 123 Appendix F contains detailed descriptions of Platform commands See Platform Commands on page 133 Appendix G contains detailed descriptions of Sensor commands See Sensor Commands on page 153 Appendix H contains detailed descriptions of service processor sp commands See Service Processor Commands on page 161 Related Documentation Application Title Part Number Safety notices and Sun Fire V20z and Sun Fire V40z Servers Safety 817 5251 xx international and Compliance Guide compliance certification statements Safety information Important Safety Information for Sun Hardware 816 7190 xx Systems Hardware installation Sun Fire V20z and Sun Fire V40z Servers 817 5246 xx and initial Installation Guide configuration Operating system Sun Fire V20z and Sun Fire V40z Servers Linux 817 5250 xx installation Operating System Installation Guide Service and Sun Fire V20z and Sun Fire V40z Serve
202. y the server NWSE_NoPermission 6 Not authorized to perform this operation Appendix H Service Processor Commands 165 SP Enable DNS Subcommand Description Configures the DNS configuration on the SP Because applications do not see updated DNS resolver configurations in etc resolv conf until they are restarted this command restarts server processes that depend on DNS This currently includes the sshd daemon and the Security Manager Format Command format sp enable dns n nameserver NAMESERVER IP s searchdomain SEARCH DOMAIN TABLE H 8 lists the arguments for this subcommand TABLEH 8 Arguments for Subcommand sp enable dns Argument Description n nameserver Displays the nameserver IP addresses If there is more than one the addresses print on separate lines s searchdomain Displays the search domain s If there is more than one the search domains print on separate lines Return Codes TABLE H 9 lists the return codes for this subcommand TABLEH 9 Return Codes for Subcommand sp enable dns Return Code ID Description NWSE_Success 0 Command successfully completed NWSE_InvalidUsage L Invalid usage bad parameter usage conflicting options specified NWSE_RPCTimeout 2 Request was issued but was not serviced by the server RPC procedure timed out and the request may or may not have been serviced by the server NWSE_NoPermission 6 Not authorized to perform
203. z and Sun Fire V40z Servers Server Management Guide May 2004 CHAPTER O SNMP Server Management You can manage your server using the Simple Network Management Protocol SNMP Simple Network Management Protocol Simple Network Management Protocol SNMP is a network management protocol used almost exclusively in TCP IP networks SNMP provides a means to monitor and control network devices and to manage configurations statistics collection performance and security on a network SNMP based management allows for third party solutions to be used This includes products such as HP OpenView and CA Unicenter The base component of an SNMP solution is the Management Information Base MIB The MIB is included on the Sun Fire V20z and Sun Fire V40z Servers Network Share Volume CD This configuration is beneficial when for example you have a cluster of machines serving Web content and the platform is connected to the Internet but the SP is protected and only accessible on an internal network 41 SNMP Integration SNMP is an open network management technology that enables the management of networks and entities connected to the network Within the SNMP architecture is a collection of network management stations and managed nodes Network management stations execute management applications which monitor and control managed nodes Managed nodes are devices such as hosts gateways and so on which have management agents respo
Download Pdf Manuals
Related Search
Related Contents
Manual 450.cdr IISI Cockpit V2 TXG1, TXE30 – 200, TXE-E Samsung UN32F5000 User's Manual Targus Zierra Microsoft SQL Server User Guide Benutzerhandbuch - Amazon Web Services Manuel Technique Crochets Monkey Hook® Pelican Water PC1000-R Instructions / Assembly BENEFICIOS Copyright © All rights reserved.