Home
Sub-Zero UC-24CI4 User's Manual
Contents
1. Refer to specifications on the following pages IMPORTANT NOTE To operate properly the door must open a minimum of 90 Use a minimum 3 76 filler in corner installations to assure a 90 door opening Allow enough clearance in front of the unit for full door swing 5 subzero com specs TOOLS AND MATERIALS REQUIRED Appliance dolly able to support 130 Ibs 59 kg Level 2 6 m 4 1 2 m recommended Phillips slotted screwdriver sets e Wrench set allen wrench set e Crescent wrenches e Various sized pliers e 5 16 hex bolt nut driver e Drill and assorted drill bits e Model 24 1 4 1 2 m of 1 4 copper braided stainless steel or PEX tubing and saddle valve for water line do not use self piercing valves e Model UC 24CI Tubing cutter Masonite plywood 1 pressed fiberboard cardboard or other suitable material to protect finished flooring Site Preparation Electrical Requirements The electrical supply should be located within the shaded area shown in the illustration below Follow the National Electrical Code and local codes and ordinances when installing the receptacle A separate circuit servicing only this appliance is required IMPORTANT NOTE The electrical outlet must be placed so the grounding prong is to the right of the thinner blades The outlet must be flush with the back wall Model UC 24RO is designed and safe for use in outdoor applica
2. There are key details that you should take special care to observe during the installation By reading these instruc tions carefully you will make the installation process easier problem free and most importantly safe Any questions or problems regarding the installation should be directed to your authorized Sub Zero dealer or Sub Zero customer care at 800 222 7820 You may also check the contact amp support section of our website subzero com Location of rating plate Important product information including the model and serial number of your unit are listed on the product rating plate located inside the cabinet in the upper left area of the unit Refer to the illustration Undercounter Specifications Undercounter Models OVERALL DIMENSIONS lt 237 8 606 gt lt 24 610 gt 34 864 14 102 1 253 8 645 13 4 44 SPECIFICATIONS Shipping Weight Ibs kg All Models 130 59 OPENING DIMENSIONS lt 24 610 OPENING DEPTH SIDE VIEW K 24 610 OPENING DEPTH 341 2 876 OPENING HEIGHT TOP VIEW 24 610 OPENING WIDTH FRONT VIEW Site Preparation Before You Start Make sure the opening dimensions door clearance electrical service and plumbing are correct for the model you are about to install
3. osmosis water filter system may not be able to maintain the minimum water pressure consistently Plumbing Requirements Water Supply Line 1 4 OD copper braided stainless steel or PEX tubing Water Pressure 20 100 psi 1 4 6 9 bar Excess Water Line for Connection 26 660 min SHADED AREA EXTENDS 1 2 13 FROM BACK WALL 2 51 1151 2 394 3 76 FRONT VIEW Location of water supply Undercounter Installation Unpack the Unit Before moving the undercounter unit into position make sure all opening dimensions electrical and plumbing requirements are complete and accurate IMPORTANT NOTE The floor under the undercounter unit must be at the same level as the surrounding finished floor to allow for removal of the unit for servicing Use an appliance dolly to move the undercounter unit near the installation opening Position the dolly at the side of the unit to prevent damage to finished surfaces Remove and discard all packing materials and tape IMPORTANT NOTE Do not discard the kickplate anti tip bracket hardware and the shipping bolts that hold the wood to the bottom of the unit leveling legs These items will be needed for the installation For models UC 24BG 24 the roller assembly wine shelves should be removed to reduce weight and prevent them from rolling To remove pull the shelf out to its full extension gently and evenly lift up
4. INSTALLATION GUIDE Undercounter Refrigeration SUB ZERO Contents Undercounter Refrigeration 3 Undercounter Specifications 4 Site Preparation 5 Undercounter Installation 7 Service Information 14 Features and specifications are subject to change at any time without notice Visit subzero com specs for the most up to date information IMPORTANT NOTE Throughout this guide dimensions in parentheses are millimeters unless otherwise specified Important Note To ensure the safe and efficient installation of Sub Zero equipment please take note of the following types of highlighted information throughout this guide IMPORTANT NOTE highlights information that is especially relevant to a problem free installation CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed SUB ZERO Undercounter Refrigeration 3 subzero com specs Sub Zero Undercounter Refrigeration IMPORTANT NOTE The importance of the installation of the Sub Zero undercounter unit cannot be overempha RATING PLATE sized Installation should be done by a qualified installer Before you begin the installation process it is recom mended that you read this entire installation guide
5. al frame on the door has numerous mounting holes on each side of the door This is to accommodate Sub Zero accessory handles and provide for easy attach ment of the handle through the door frame If you choose not to use the pre drilled handle mounting holes it will be necessary to fasten the handle from the rear of the door panel only or drill one or more additional holes through the metal frame of the door The cross section illustration shows how the hole passes through the door frame The hole center is on the small locator groove in the front of the frame A 1 4 6 diameter hole is made in the front wall of the extrusion and a 13 32 11 diameter hole through the rest of the frame Undercounter Installation 12 Overlay Panel Installation CAUTION The model UC 24BG glass door is made with a sealed double wall tempered glass core The drill must not contact this core when drilling Be sure the hole is centered on the small groove in the front of the door frame and the drill passes squarely through the frame If you are inexperienced with drilling fasten the handle from the rear of the door panel only IMPORTANT NOTE For model UC 24BG install screws in all the mounting holes in the door frame The nature of the door panel with a narrow outer rim and no connecting center member requires the support provided by the glass door After the door panel installation is complete apply the cover patches or plugs provided
6. ed Child entrapment accidents can be tragic J SUB ZERO The information and images in this guide are the copyright property of Sub Zero Inc Neither this guide nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Sub Zero Inc Sub Zero Inc all rights reserved Wolf Wolf 8 Design Wolf Gourmet W amp Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance Inc Sub Zero Sub Zero amp Design Dual Refrigeration Constant Care and The Living Kitchen are registered trademarks and service marks of Sub Zero Inc collectively the Company Marks All other trademarks or registered trademarks are property of their respective owners in the United States and other countries SUB ZERO SUB ZERO INC 44848 MADISON WI 53744 SUBZERO COM 800 222 7820
7. ilt into cabinetry and cannot be used in a freestanding applica tion gt lt 7 8 Undercounter Installation Overlay Panel Installation MODELS UC 24R AND UC 24C I Inspect the overlay door panel for minimum thickness weight limit Remove the two panel mounting brackets attached to the front of the door and set aside Place the overlay panel lying face down on a protected surface to ensure that the front is not scratched or damaged Position the plastic template provided flush with the lower edge of the door panel Be sure you are following the exact location for the right hand RH or left hand LH door swing Refer to the illustration below for placement of the mounting brackets Once you have located the proper placement for the brackets mark the pilot holes remove the template and drill pilot holes for mounting the brackets It is best to start with a few holes position the bracket drill the remaining pilot holes and then secure the mounting bracket with the 8 x 1 2 screws provided A CAUTION Exercise caution when drilling holes for mounting hardware This is especially critical with inset panels 6 21 5 8 549 gt Lo 23 RH DOOR SWING 151 16 382 35 8 31 2 92 89 Y t 233 4 603 LH DOOR SWING Overlay panel bracket location 10 Before attaching the overlay panel to the door insert two
8. ndles must be attached directly to the overlay panel BEVERAGE CENTER MODEL UC 24BG Stainless steel model UC 24BG S is shipped from the factory with the stainless steel door panel and tubular or pro handle in place No panel installation is required For overlay model UC 24BG O a decorative frame door panel must be provided to surround the glass The inside edges of the panel that will be visible through the glass must be finished Refer to the chart for panel specifica tions You may also use your own handle hardware to match sur rounding cabinetry If you do not use the pre drilled holes on the door of the unit you will need to attach the handle directly to the overlay panel IMPORTANT NOTE For installations at or above 5 000 1524 m in altitude a special high altitude glass door unit must be ordered A CAUTION A solid panel must not be installed over the glass door as this may cause moisture to form behind the panel 9 subzero com specs Panel Specifications OVERLAY PANEL w H UC 24R UC 24BG 24 233 4 603 301 16 764 RAILS AND STILES w UC 24BG 21 4 57 min MAX PANEL WEIGHT UC 24R and UC 24C I 20 Ibs 9 kg UC 24BG 10 Ibs 5 kg MIN PANEL THICKNESS Overlay Panels 5 8 16 OUTDOOR MODEL UC 24RO Model UC 24RO is shipped from the factory with the stainless steel door panel and tubular or pro handle in place No panel installation is required IMPORTANT NOTE Model UC 24RO must be bu
9. nit This will remove any debris that may be present in the tubing from installing the new water line IMPORTANT NOTE Let your customer know that the ice maker will not produce ice immediately and that the first few batches of ice produced should be discarded Allow 24 hours for proper ice production IMPORTANT NOTE Water lines must not be exposed to freezing temperatures Exposure could cause damage to the unit and home INSTALL KICKPLATE Install the kickplate using the two 10 x 1 2 stainless steel screws that are provided with the kickplate Refer to the illustration below The kickplate must be removed for servicing The floor cannot interfere with removal Do not cover the louvered section of the kickplate to allow proper air circulation Turn power back on to the electrical outlet LEVELING LEGS Location of leveling legs Kickplate installation Undercounter Installation Door Panel MODELS UC 24R AND UC 24C l Models UC 24R and UC 24C I can be fitted with a custom overlay or stainless steel door front panel A stain less steel door panel with tubular or pro handle is available as sales accessory Installation of the stainless steel panel will be required For the overlay application a decorative door panel and handle hardware must be provided Refer to the chart for panel specifications You can match your handle hardware with surrounding cabinetry or use a Sub Zero accessory handle Ha
10. on both sides of the front of the shelf and remove Reverse the procedure to reinstall the shelf A CAUTION Before moving the undercounter unit into position protect any finished flooring with appropriate materials and secure the door closed 7 subzero com specs Anti Tip Bracket To prevent the unit from tipping forward and provide a stable installation the unit must be secured in place with the anti tip bracket An anti tip bracket and hardware is provided with the undercounter unit Placement of the anti tip bracket is critical to a stable installation The anti tip bracket must be installed securely The anti tip bracket should be attached to the wall behind the unit with the bracket flange located immediately above the top of the unit Refer to the illustration below For installations that cannot accommodate the anti tip bracket the optional countertop bracket provided can be used to secure the undercounter unit This bracket will secure the front of the unit to the underside of the coun tertop above the unit Refer to the illustration below If it is not possible to use the countertop bracket wedge shims along the sides and top of the unit to secure COUNTERTOP BRACKET ANTI TIP BRACKET Anti tip bracket Countertop bracket Undercounter Installation Installation IMPORTANT NOTE If the undercounter unit has been laid on its back or side you must allow the unit to stand uprigh
11. over the holes on the inside surface of the door CAUTION The cover patches or plugs are part of the insulation system on the door of the undercounter unit Be sure to cover all the holes in the door that were used Hinge Adjustment IMPORTANT NOTE The undercounter unit should be properly leveled before door hinge adjustments are made The top and bottom cabinet hinges are held in place with three permanent adjustment screws If the door needs adjustment loosen the adjustment screws and reposition the door Once in position tighten the adjustment screws Refer to the illustrations below TOP DOOR HINGE ADJUSTMENT SCREWS BOTTOM DOOR HINGE ADJUSTMENT SCREWS o A Bottom hinge adjustment Top hinge adjustment Undercounter Installation Installation Checklist To ensure a safe and proper installation the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked Has all packing material been removed Turn the unit on Is it operating properly If not is the unit plugged in Is the control turned on Is the power cord plugged into a properly grounded 3 prong outlet which has been installed in accordance with all applicable electrical codes Has the unit been secured in place with the anti tip bracket Is the unit level Are all leveling legs making contact with the floor Is the kickplate installed
12. properly Is the water supply connected model 24 1 Have you checked for leaks Is the door panel attached securely and properly aligned Is the door aligned for proper appearance and operation Have any installation or service problems been noted on the product registration card Has the registration card been mailed in Has the stainless steel door or panel been inspected for any imperfections This is to be done by the dealer or installer with the customer upon completion of the installation Stainless steel panels are covered by a limited 60 day parts and labor warranty for cosmetic defects 13 subzero com specs Service Information Service Information If service is necessary maintain the quality built into your undercounter unit by calling Sub Zero factory certified service For the name and number of Sub Zero factory certified service nearest you check the contact amp support section of our website subzero com or call Sub Zero customer care at 800 222 7820 When calling for service you will need the model serial numbers of your unit Both numbers are listed on the product rating plate located inside the cabinet in the upper left area of the unit Refer to the illustration below RATING PLATE Location of rating plate 14 If you are storing or disposing of your old refrigerator or freezer please do it safely Remove the doors or tightly secure the doors clos
13. screws one in the center of each mounting position just far enough that the slotted holes on the hinge side door panel bracket will slide under the heads These positioning screws will support the door panel during installation and adjustment Refer to the illustration below Install the door panel by engaging the tabbed bracket to the handle side of the door first and then sliding the hinge side mounting bracket onto the positioning screws on the hinge side of the door The panel can be adjusted 1 4 6 up and down and side to side Once the door panel is in place and adjusted correctly attach the four remaining 10 x 1 2 screws to the hinge side mounting bracket and install the magnetic decorative caps as shown in the illustration below DOOR PANEL BRACKET SCREW Panel installation Undercounter Installation Overlay Panel Installation BEVERAGE CENTER MODEL UC 24BG Inspect the overlay door panel for minimum thickness weight limit and finished inside edges Decide if the handle will be attached through the glass door frame or just through the decorative door panel If it is just through the door panel the handle must be attached first The overlay door panel is attached using 8 x 5 square drive screws passing through the door frame from the rear behind the gasket into the panel The door panel is marked for screw locations by the use of tenon centers which are temporarily inser
14. t for a minimum of 24 hours before connecting power With the undercounter unit near the installation opening plug the power cord into the electrical outlet With power applied to the unit check for lighting and cooling Once you are satisfied that the unit is operating properly shut off power to the electrical outlet at the circuit breaker and proceed LEVEL THE UNIT Level the unit before sliding it into position Leveling cannot be completed with the unit pushed back in the installation opening Using an adjustable wrench or pliers turn each of the four leveling legs clockwise to raise the unit and counterclock wise to lower the unit For the location of the leveling legs refer to the illustration AWARNING To reduce the possibility of the unit tipping forward the front leveling legs must be in contact with the floor POSITION THE UNIT Slide the undercounter unit back into position in the installation opening Make sure it contacts the anti tip bracket for a stable installation The undercounter unit provides the best access to its contents when the front surface of the door panel extends out from surrounding cabinets approximately 1 4 6 WATER LINE CONNECTION MODEL 24 For model UC 24Cl connect the plastic tubing from the ice maker to the house water supply line with the fitting connection kit provided Check all water line fittings for leaks Purge the water line prior to final connection to the u
15. ted into the 1 4 6 diameter holes in the front of the door frame Refer to the illustration below With the unit secured in place and the door closed the panel is held in the desired position on the door and rapped by hand from the front putting center marks on the rear surface of the panel If the door panel is made of such a material that pre drilling is needed all of the mounting holes should be marked If not only enough holes to hold the panel in place temporarily are necessary GASKET F 13 32 11 lt DIAMETER 1 4 6 DIAMETER TENON CENTER Tenon centers Door frame cross section 11 subzero com specs Remove the door panel from the door frame and remove tenon centers Open the door Using the center marks to locate screws drive the screws into the panel through the black tape on the door frame The screw holes inside the door are hidden under a cover flap on the door gasket It is necessary to lift the flap to insert the screws Use as many screws as necessary to hold the door panel in place securely IMPORTANT NOTE After the first three or four mounting screws are in place but not completely tightened close the door and check the panel fit This is the time to make small adjustments Once you are satisfied with the appear ance open the door and add the rest of the screws Check all screws for tightness The met
16. tions When installed outdoors a ground fault circuit interrupter is required to reduce the risk of electrical shock A GFCI is not recommended for use with other undercounter models and may cause interruption of operation Do not use an extension cord or two prong adapter Electrical ground is required on this appliance Electrical Requirements Power Supply 115 V AC 60 Hz Circuit Breaker 15 amp Receptacle 3 prong grounding type LEFT SIDE OF OPENING 2 51 151 2 394 3 76 FRONT VIEW Location of electrical supply Plumbing Requirements MODEL UC 24Cl For model UC 24Cl the water supply line for the ice maker should be located within the shaded area shown in the illustration below Connect the water line from the ice maker water valve to the house water supply line Use an easily accessible shut off valve between the water supply and the unit Do not use self piercing valves A saddle valve kit is available from your authorized Sub Zero dealer A line filter is required when water conditions have a high sediment content The ice maker operates on water pressure of 20 psi 1 4 bar to 100 psi 6 9 bar A reverse osmosis system can be used provided there is a consistent water pressure of 20 psi 1 4 bar to 100 psi 6 9 bar supplied to the water valve at all times A copper line is not recommended for this application IMPORTANT NOTE In some cases a reverse
Download Pdf Manuals
Related Search
Related Contents
Pelonis WM-HO202C Oil Filled Radiator Heater - Oil Heater manual HO INTEGRAL - Leroy Merlin Appliance Manual ( A Government of India Enterprise ) PO Udayan Service-Manual Mini State Industries SEH-200 User's Manual balança eletrônica pesadora / contadora modelo 3400 取扱説明書 - 日立工機 品番AKFーPV383N Copyright © All rights reserved.