1. as follows 22 x OLD TDO CODE SILIL NEW TDO CODE NEW TDO CODE DELETING THE Time DeLay Overrive Cope The TDO code is deleted as follows 7 4 master code or supervisor code 9 position number r oe 7 MANAGEMENT EmpLoyee Access Mone wp Types oF MaNAGEMENT EMPLoYEE Access Management employee access is an alternate way to operate this lock to meet special security needs Your lock can be programmed so that during everyday operation the master code holder or supervisor code holder can enable the lock It can then be opened using any valid lock code master supervisor or user code until it is disabled There are two varieties of the enable disable function In the first version only the holder of the master code and supervisor code can enable and disable the lock In the second version user code holders can also disable the lock The master code and supervisor code holders are the only persons who can both enable and disable the lock PROGRAMMING THE Lock FOR MaNAGEMENT EmpLoyee Access Mone Your lock can be programmed so that the master code holder or supervisor code holder can use his code to enable the lock for opening by any valid lock code When either the master code or supervisor code is again to toggle the lock it can no longer be opened This process can be repeated whenever appropriate DU ya ae 3 2 K master code 24 2 anm d SARGENT AND GREENLEAF Page 6 gt ENABLING THE Lock IN MAN
2. The time delay override code if set is designated as code 9 e Each time a button is pressed the lock acknowledges it by sounding a beep and the LED on the keypad will light momentarily as the beep sounds If it does not check your battery or batteries to make sure it is fresh and connected properly then try again e All codes must contain six digits or six letters Any digit or letter can be used as many times as you wish For instance the following codes while not recommended will operate the lock 555555 OR JJJJJJ e All codes end with This signals the lock that you have finished entering all digits of the code To 2asc 30er e f you pause more than 10 seconds DR between button presses when entering a code the lock will assume you do not want to continue and it will reset itself to the original code To open the lock begin the code entry sequence once again from the first step Tres Bruv Ow 0z e f you realize you have pressed an incorrect button when entering a code press x or simply pause ten seconds or more then begin entering your code again e f five incorrect codes are entered in a row the S amp G X D Drive lock will shut down for a period of ten minutes This is a security feature Entering a code during this period will result in two long error tones braps Pressing any buttons during the lockout period will not affect the penalty timer After
3. If the battery in your lock needs to be replaced twenty consecutive beeps will be heard after the The ensuing beep pattern will tell you if your lock is configured last number of the code and have been pressed The battery in single user multiple user or dual control mode will have to be replaced before the lock can be opened peerpamern fT Note If the battery is getting low but the lock still has enough power to function it will emit five sets of two short high pitch 2ND SET OF 1 BEEP INDICATES 2 BEEPS INDICATE 3 BEEPS INDICATE beeps before opening This is an early signal that battery failure BEEPS A DICATES SINGLE USER MULTIPLE USER DUAL CONTROL is a p p roa ch i ng BEEP PATTERN REFERENCE TABLE Lock Activity Beep Pattern Emitted A code has been entered to start a time delay 3 short high pitch beeps An incorrect code has been entered 1 long continuous bee A code has been entered during a penalty 2 long continuous lockout period Enter 4 3 x eeps Time delay countdown period in effect 1 short high pitch beep every 10 seconds Time delay countdown finished 10 short high pitch beeps Opening window period in effect 2 short high pitch beeps every 6 seconds Low battery warning 5 sets of 2 short high pitch beeps Battery too low for lock to function 20 short high pitch beeps lock does not open Optional audit trail download completion Lock is enabled in Management Employee mode Lock is disabled in Management Employe
4. any valid code other than the TDO code Then within one minute enter the TDO code The lock will open immediately This type of time delay override places a secondary control on the TDO code holder adding a measure of extra security w gt Turnine Sinece Controt Time DeLay Overrive ON If your lock was ordered with time delay override capability single control TDO can be turned on as follows DIDID fat 46 mastercole 2 2 7 w gt Turnine Duar Controt Time Decay Overrive ON If your lock was ordered with time delay override capability dual control TDO can be turned on as follows 4 6 K master code Pi 1 7 w gt Turnine Time Derav Overrive OFF 4 6 K master code 0 0 7 When time delay override is turned off the time delay override code is erased PIN position 9 can now be used to store a regular user code anm d SARGENT AND GREENLEAF OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series After this programming procedure is completed the lock will be disabled If a valid code is entered the lock will emit a double beep but will not open CREATING THE TIME DeLay Overrive Cope The TDO code is located in position 9 It is programmed as follows Pp JIS 7 4 master code or supervisor code 9 position number pay py new TDO code new TDO code gt CHANGING THE Time DeLay Overrive Cove An existing TDO code can only be changed by the holder of that code
5. control on the TDO code holder adding a measure of extra security The following example uses the factory set master code 1 2345 6 to start the time delay then a TDO code of 98765 4 is used to open the lock without waiting for the time delay period to expire Enter123456 987654 gt USEFUL OPERATING INFORMATION The lock will emit a long error tone if an incorrect or incomplete code is entered If five or more incorrect codes are entered in a row the lock will go into a ten minute lockout period If you attempt to enter a code during this lockout period two long error tones will be heard Simply wait ten minutes then attempt to operate the lock again The lockout period cannot be bypassed You must wait for it to time out anma d SARGENT AND GREENLEAF OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series w gt Cuancine Your Own Cove Cuancine Creatine Devetine CODES Creatine A Management Reset Cove A management reset code can only be created before the lock s master code is changed for the first time It can later be used to reset the lock in the event the master code is lost Resetting the lock this way deletes the time delay override code supervisor code and all user codes and it allows you to set a new master code at the same time This reset does not affect the time delay or opening window duress audit trail or lock access method It is important to note that the
6. re lock the S amp G X D Drive turn the keypad back counterclockwise to stop When the mechanism re locks it will emit a double beep consisting of a low tone followed by a slightly higher tone If you do not hear the double beep the mechanism is not properly locked gt With Time DeLay Active Time delay enforces a waiting period between entry of the first code and opening of the safe This feature is a proven deterrent to armed robbery Any valid lock code can be used to start the time delay When this code is entered the lock beeps three times and begins counting down the delay period The lock will beep once every ten seconds during the delay period At the end of the delay period the lock will beep ten times rapidly Enter a valid code for the lock After the code is entered the lock will release for six seconds to allow you to turn the keypad and open the safe WiTH Duress Active Duress sometimes referred to as silent alarm is a feature that causes an alarm signal to be sent when a code is entered This capability must be enabled in the lock and an optional duress module must be added to the lock and connected to an existing alarm system for this feature to work A duress code one which triggers the alarm signal is simply any valid lock code with 1 added to the last digit For instance if you create a user code of 2 2 2 2 2 2 the duress version of this code is 2 2 2 2 2 3 This code is valid for operating th
7. AGEMENT EmpLovee Access Mone Before valid codes can be entered to open the lock it will be necessary to perform the following procedure JIDD 5 5 amp master code or supervisor code Note that the lock emits four beeps to indicate that it can now be opened by any valid code gt Disaiing THE Lock iN MANAGEMENT EMPLoyeE Access Mone To make the lock inoperable by any code simply repeat the same programming procedure ay 5 5 master code or supervisor code Note that the lock emits two beeps to indicate that it is now disabled and cannot be opened by any code This sequence simply toggles the lock on and off to determine whether or not it can be opened by the master code supervisor code or any user code When the lock is disabled it will emit a double beep when a code is entered but will not open w gt Lettine Users Disapte THE Lock in MaNaGeMENT EmpLoyee Access Mone Only the holder of the master code or supervisor code can enable the lock but there may be circumstances under which you want user code holders to also be able to disable the lock To allow this perform the following procedure DP ha 5 6 K master code 1 1 Now after the lock is enabled by the master code or supervisor code holder any user code holder can disable it by entering the following sequence 5 5 gt any user code When the lock is disabled it will emit a double beep when a code is entered but will not open Copyri
8. IABILITY FOR DAMAGE TO OR LOSS OF PROPERTY SOUGHT TO BE PROTECTED BY ANY SUCH LOCK ax Sargent amp Greenleaf Inc SARGENT AND GREENLEAF Sargent amp Greenleaf S A A Wholly Owned Subsidiary of Stanley Security Solutions Inc 9 chemin du Croset PO Box 930 Nicholasville Kentucky 40356 USA 1024 Ecublens Switzerland Phone 859 885 9411 Phone 41 21 694 34 00 Phone 800 826 7652 FAX 41 21 694 34 09 FAX 859 887 2057 FAX 800 634 4843
9. OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series The S amp G X 3 D Drive lock combines ease of operation with security and flexibility Its advanced electronic circuit design makes it easy to open and easy to change codes Follow these instructions carefully to get the best possible use from your lock INTRODUCTION e This S amp G X D Drive lock is shipped from the factory in multi user mode with a factory master code of 123456 This code can be used to open the lock and set or change codes You should set the lock to your own unique master code e Your lock can be programmed with a management reset code that can be used to regain control of the lock in the event the master code is lost The management reset code must be programmed into the lock before the master code is changed for the first time e At your discretion the lock can be set to accept a supervisor code up to seven different user codes and a time delay override code The master code holder and the supervisor code holder if a supervisor code is set are responsible for maintaining the number of active users programmed into each lock The master code holder and the supervisor code holder can create and delete user codes e The master code is designated as code 0 The supervisor code if set is designated as code 1 The user codes if set are designated by user position numbers 2 3 4 5 6 7 and 8
10. Page 4 Any code holder can change his own code The process is 22 OLD CODE NEW CODE NEWCODE DIDID For example changing a user code of 2 2 2 2 2 2 to a new code of 2 4 6 8 3 3 would be accomplished as follows 2222222224 246833 246833 JIII gt Creating A New Cone The holder of the master code position 0 can create new codes and delete existing codes The master code can also be used to set or delete a time delay override code The holder of the supervisor code position 1 can create and delete user codes and the time delay override code The supervisor code cannot be used for any operations affecting the master code There are several code storage positions in the lock designated 0 through 9 They store the following types of codes position 0 master code position 1 supervisor code positions 2 through 8 user codes position 9 time delay override code Here is the process for creating a supervisor code JIII 7 4 amp master code 1 a ID mr new supervisor code new supervisor code To create a new user code use the following sequence In this example a new user code is being created in position 5 JIII 7 4 2 master code or supervisor code JSD BF y 5 position number new user code new user code User codes can be set in any storage position from 2 through 8 To create a new time delay override code see the time delay section Copyright 2006 Sargent am
11. e base then turn it clockwise until the yellow tab snaps back into its normal position Figure 6 Check your lock operation at least three times with the container Figure 4 door open before closing it Figure 5 E Figure 6 SARGENTANDGREENLEAF Page 10 Copyright 2006 Sargent amp Greenleaf 0z EA CH 4 p i wa WARRANTY Seller warrants that for one year from the date of shipment from Seller s point of manufacture the goods shall be free from defects in material and workmanship provided the goods are normally and properly used according to the Seller s written instructions THIS WARRANTY IS EXPRESSLY MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED S amp G DOES NOT WARRANT THAT THE GOODS ARE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE EXCEPT AS EXPRESSLY PROVIDED HEREIN Seller s entire liability and Buyer s exclusive remedy in the event that the goods do not conform to the foregoing warranty shall be Seller s repair or replacement of the goods including payment of freight costs to and from point of manufacture UNAUTHORIZED USE OF DIAL DIAL RINGS AND OR SPINDLES NOT MANUFACTURED BY THE SELLER IN CONJUNCTION WITH ITS COMBINATION LOCK PRODUCTS INVALIDATES THE WARRANTY SELLER SHALL HAVE NO LIABILITY FOR ANY CONSEQUENTIAL INCIDENTAL INDIRECT OR SPECIAL DAMAGES SELLER DOES NOT WARRANT ITS LOCK PRODUCTS TO BE IMPERVIOUS TO FORCIBLE OR SURREPTITIOUS ENTRY AND SELLER SHALL HAVE NO L
12. e lock and simultaneously triggering the duress alarm signal When the duress feature is turned on lock codes 0 1 2 3 and 9 are capable of triggering the silent alarm signal If a time delay is programmed into the lock a duress code can be used to start Copyright 2006 Sargent amp Greenleaf Page 3 code 9 is available Usine a Time DeLay OVERRIDE Cove This lock is capable of using a time delay override code if it was originally ordered with this feature and if the TDO time delay override feature is enabled As the name implies the time delay override code can be used to open the lock without waiting for the time delay period to expire This is useful for armored car cash pickups The TDO code only works when your lock uses a time delay Your lock is capable of two different types of time delay override Single control time delay override allows the TDO code holder to simply enter his code to open the lock The time delay period is completely bypassed For example if the TDO code is 987654 it would only be necessary to press the following keypad buttons to unlock the safe Enter 987654 The other type of time delay override is dual control TDO To use this type of time delay override it is necessary to start the lock s time delay by entering any valid code other than the TDO code Then within one minute enter the TDO code The lock will open immediately This type of time delay override places a secondary
13. e mode Quick REFERENCE TABLE Command Function oo Master code holder enables or disables the optional duress feature Anyone identifies the lock type Master code holder enables or disables the optional time delay override feature Master code holder enables or disables management employee mode SARGENT AND GREENLEAF Page 8 Copyright 2006 Sargent amp Greenleaf BATTERY CHANGING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series Low Bartery Conpition The S amp G X 3 D Drive lock uses one 9 volt alkaline battery which is housed in the keypad We recommend Duracell brand If the battery needs to be replaced the lock will emit five double beeps whenever it is opened If this signal is ignored and the battery becomes so weak that it will no longer operate h de Zane CJA the lock you ll hear twenty quick beeps when you enter a code 4cm Sna mno but the lock will not open You will have to replace the batte Tee i i Z Ters ruv Oww before your lock can be opened NERC Ee 4 iS p Banery REPLACEMENT PROCEDURE Always perform a battery change with the container door open The lock will NOT forget your code s during battery change The circuitry is designed to hold this information for extended periods of time even if there are no batteries installed Codes are stored in non volatile memory Step 1 Pull the yell
14. ght 2006 Sargent amp Greenleaf OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series Manacine Aupit TRAIL gt C anceLLING User Disaste in MANAGEMENT Emptovee Access Move If you decide user code holders should no longer have the ability to disable the lock perform the following procedure DU ya ae 5 6 K master code of 0 User code holders will no longer be able to disable the lock although the master code holder and supervisor code holder will still have the ability to do so Takina THE Lock Out oF Manacement Emptoyee Access Mone If you no longer want the lock to function in the management employee access mode enter the following sequence a a an 3 2 K master code or supervisor code 1 1 The lock will now operate on any valid code at any time Manacine Duress w gt Turnine Duress ON If your lock was ordered with time duress capability and an optional duress module is installed the feature can be turned on as follows 3 8 K master code p 1 Turnie Duress OFF The duress feature can be turned off as follows 3 8 K master code 9 0 VERIFYING Duress If duress is enabled you can tell if the lock has sent a silent alarm Fifteen minutes or more after a duress signal has been sent press and hold down the gt button for at least four seconds The lock will emit a continuous alternating series of high and low pitch beeps to indicate that a duress signal ha
15. lock makes no sound when any of the keys are pressed dead batteries are likely to be the cause Follow the battery replacement procedure in this manual 4 Your lock may be in penalty mode If the lock interprets your button presses as four or more incorrect codes in a row it will lock you out for ten minutes During this period the lock will ignore any keypad inputs At the end of ten minutes enter a valid code to open the lock If all of the preceding remedies have been exhausted and the lock still does not open contact a qualified safe technician in your area for professional service Copyright 2006 Sargent amp Greenleaf OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series the time delay for the opening code at the end of the time delay or for both codes The silent alarm signal will be sent each time a duress code is entered Note Lock codes 4 8 are not available if the duress feature is turned on If time delay override is disabled or not used lock OPENING THE Lock Wirth No Time Detay A valid code is needed to open the lock This is how to open the lock with the original factory master code of 1 2 3 4 5 6 Make sure the keypad is turned counterclockwise to stop Enter 123456 Then within six seconds turn the keypad clockwise about 70 degrees until it comes to a positive stop Do not put any pressure on the safe handle until after the keypad has been turned To
16. management reset code can only be set or changed before the lock s master code is changed for the first time It is recommended that the management reset code be stored off premises as an additional security measure The management reset code is different from other lock codes It is composed of seven digits two of which are pressed at the same time This two digit pair must be either 0 1 or 0 3 For instance a management reset code could be 3 6 2 0 3 1 9 The 0 and 3 must be pressed simultaneously The 0 1 or 0 3 can be located anywhere in the management reset code and the digits 0 1 and 3 can also be used as individual digits anywhere in the code For instance 0 3 1 0 0 1 0 would be an acceptable MRC Only the 0 1 in brackets would be pressed simultaneously The lock s MRC management reset code may have been preset at the factory A factory MRC can be set or changed using the following procedure 67 123456 DIII NEW MRC NEW MRC Usine a Management Reset Cove Use the MRC only when you have lost or forgotten the master code for the lock You should make up a new six digit master code before implementing the reset Following is the procedure 6 7 k MRC NEW 6 DIGIT MASTER CODE NEW 6 DIGIT MASTER CODE DIDID After the final three beeps indicating completion of the reset the lock will beep once for each time the MRC has been used including the current usage anma d SARGENT AND GREENLEAF
17. me delay to expire then begin the appropriate programming sequence rather than opening the lock The programming sequence for setting changing or deleting a time delay period is as follows The period can be anywhere from 1 to 99 minutes 7 4 master code 9 0 a JID JID length of desired time delay period length of desired time delay period To delete a time delay enter 0 for the desired time delay length Copyright 2006 Sargent amp Greenleaf Page 5 The length of the opening window period is set as follows The period can be anywhere from 1 to 10 minutes 7 4 2 master code 9 1 7 Eai length of desired opening window period JID length of desired opening window period Manacine Time DELAY OVERRIDE This optional feature determines whether or not you can override the time delay waiting period There may be special circumstances that make it desirable to open the lock before time delay expires such as during cash pickups by an armored car service Time delay override only works when the lock is being operated in time delay mode Your lock is capable of two different types of time delay override Single control time delay override allows the TDO code holder to simply enter his code to open the lock The delay period is completely bypassed The other type of time delay override is dua control TDO To use this type of time delay override it is necessary to start the lock s time delay by entering
18. ow spring loaded tab at the top of the keypad Figure 1 toward you slightly It is not meant to separate from the keypad Once it s pulled forward carefully turn the l keypad ring counterclockwise to stop Then pull the ring away Figure 2 from its base far enough to expose the battery compartment Step 2 Put your finger in the battery compartment and carefully pull out the battery cables Figure 2 There should be enough slack to allow you to pull the connector and old battery outside the compartment Disconnect the old battery Step 3 S amp G strongly recommends Duracell brand alkaline batteries No matter what brand is used the battery must be alkaline Align the battery and connector terminals and snap the battery to the connector Figure 3 Figure 3 Copyright 2006 Sargent amp Greenleaf Page 9 SARGENT AND GREEMLEAT BATTERY CHANGING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series Step 4 Carefully slide the battery behind the keypad into the cavity that is designed to hold it Figure 4 Be sure the battery has dropped all the way to the bottom of the cavity Step 5 Gently place any excess wire into the cavity Make sure it is not in a position to be caught between the keypad ring and the keypad base when the ring is pushed back against the base Figure 5 Step 6 Once the wires are safely positioned out of harm s way push the keypad ring back up against th
19. p Greenleaf OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series CHANGING THE OPENING Winpow Duration DELETING AN Existine Cove The holder of the master code position 0 can delete any other code The master code cannot be deleted under any circumstances The holder of the supervisor code position 1 can delete user codes The supervisor code cannot be used to delete the master code or itself Here is the process for deleting a supervisor code Tg ID be 7 4 2 master code 1 JIS To delete a user code in position 5 use the following sequence Piy E IT ee IH 7 4 2 master code or supervisor code To delete a time delay override code see the time delay section Manacine Time DeLay CREATING CHANGING DELETING A Time DELAY Time delay is a security feature that enforces a predetermined waiting period between the entering of a valid lock code and the actual opening of the lock The delay period can be set from 1 to 99 minutes The opening window is a period of time immediately after the time delay during which you can enter a valid lock code to open the lock The factory default opening window is 2 minutes but it can be changed to any value between 1 and 10 minutes Note Changes to an existing time delay or opening window can only be accomplished during the opening window period This means you must enter a valid operating code for the lock wait for the ti
20. s been sent Reset the duress indication by entering the lock s master code within one minute after the verification signal ends Copyright 2006 Sargent amp Greenleaf Page 7 CAPTURING AN AupiT TRAIL Your lock must have been ordered with this option Using the audit trail feature also requires an optional keypad extension S amp G part number 6101 201 as well as an audit trail software kit S amp G part number 6103 100 The lock records the last 63 events in the order they occurred After the 63rd event the lock overwrites the oldest event with the new one so you always have access to the most recent 63 events To download the audit trail through the optional keypad extension hold the Dallas iButton key provided in the audit trail kit to the receptacle in the keypad extension and enter the following 2 8 K master code The lock will beep three times when the download is complete You may then remove your iButton key from the keypad extension s receptacle The information now stored in the key is a copy of what is in the lock The lock s audit information is not erased in the download process anm d SARGENT AND GREENLEAF OPERATING INSTRUCTIONS S amp G Z D Drive Multi User Electronic Safe Lock 2005 Series INFORMATION TABLES Low Bartery Conpition DETERMINING Your Lock s Mone oF OPERATION The S amp G X 3 D Drive lock uses a 9 volt alkaline battery We recommend Duracell brand
21. ten minutes the lock should operate normally The lock can also go into the lockout period during programming if it interprets an incorrect programming sequence as five or more consecutive incorrect code entries If the lock emits two long error tones braps during repeated programming attempts it is in lockout mode Wait ten minutes then try again e For UL installations the maximum number of working codes allowed is one e Personal data which can be directly related to a code holder such as a birthdate should not be used in making up a lock code Avoid codes which can be easily guessed e After the lock is changed to a new code the lock function must checked by locking and unlocking it several times with the container door open Make sure it functions correctly before closing the door Note This lock has been Listed by Underwriters Laboratories for use with the following S amp G keypad s 6130 2XX and 6130 3XX cam Sargent amp Greenleaf Inc A Wholly Owned Subsidiary of Stanley Security Solutions Inc PO Box 930 Nicholasville Kentucky 40356 USA Phone 859 885 9411 Phone 800 826 7652 FAX 859 887 2057 FAX 800 634 4843 Copyright 2006 Sargent amp Greenleaf SARGENT AND GREENLEAF Sargent amp Greenleaf S A 9 chemin du Croset 1024 Ecublens Switzerland Phone 41 21 694 34 00 FAX 41 21 694 34 09 Document 630 735 Revised 7 25 06 OPERATING INSTRUCTIONS S amp G Z D Drive M
22. ulti User Electronic Safe Lock 2005 Series 2 If the lock chirps when keys are pressed but it will not open the batteries may be drained to the point that they will not operate the lock s solenoid Follow the battery replacement procedure in this manual To Open THE Lock Make sure the keypad is turned counterclockwise to stop Press the code digits or letters in order followed by Then within six seconds turn the keypad clockwise about 70 degrees until it comes to a positive stop Do not put any pressure on the safe handle until after the keypad has been turned To re lock the S amp G D Drive turn the keypad back counterclockwise to stop Note The Master Code Holder is responsible for maintaining the number of active users programmed into each lock In Case oF TROUBLE If your lock should fail to open when a valid code is entered check for the following 1 The boltwork of a safe can under certain conditions place pressure on the side of the lock s bolt This is often caused by something inside the safe pressing against the door or by something caught between the safe door and its frame When this occurs the lock will not operate properly To relieve side pressure on the lock bolt move the safe s handle to the fully locked position make sure the keypad is turned counterclockwise to stop then re enter a working code The lock should open anma d SARGENT AND GREENLEAF Page 2 3 If the