Home
SPX Cooling Technologies Marley Sigma Wood CoolingTower 1000 User's Manual
Contents
1. Marley Sigma 1000 1200 Cooling Tower SP COOLING TECHNOLOGIES The Marley Difference You ll enjoy single source responsibility and reliability because we design and manufacture virtually all major cooling tower components All Marley components are designed and selected to be part of an integrated system For example the spray pattern from nozzles and the pressure drop through drift eliminators both affect a fill s heat transfer capacity So we include that impact in our thermal analysis Drift eliminators must be effective at the air velocities where fill is most efficient So we ve carefully designed both components to work together efficiently o o o o o o o o o o How many other cooling tower companies can offer you this assurance They may use Brand A nozzles with Brand B fill and Brand C drift eliminators When they all come together the whole may be less than the sum of the parts Our total system approach assures that all the parts work together to provide you the greatest total performance And because we design specifically for cooling towers all our components will provi
2. Easily removable Choose either treated fir frames or galvanized steel U edge frames Removable treated fir plywood covers keep upper basins free of leaves and debris They also tend to retard growth of algae by keeping ultraviolet radiation away from the warm water in the basins Covers may be used as a working surface for tower maintenance Accessory Additional Access Door Wood Stairway Steel Ladder Ladder Safety Cage Plenum Walkway Ladder Extensions Premium Hardware Fire Protection Redwood Fan Deck Description and Remarks Extra access door on single cell towers offers easy access through either endwall Pressure treated Douglas fir 45 stairway located at tower endwall provides access to the fan deck Choose a stairway in place of one endwall ladder or use both ladders as well as the stairway Handrails and kneerails are standard so design conforms to OSHA standards Galvanized steel ladder conforms to OSHA standards May be in place of or in addition to standard aluminum ladders Galvanized steel circular framework bolts to ladder siderails and conforms to OSHA standards Cages extend from the top of the guardrail to about 7 above the base of the ladder If the tower fan deck is more than 20 above roof or grade OSHA requires safety cages Pressure treated Douglas fir plenum walkways extend the full length of the tower from access door to access door above the water line Guardrails ar
3. Motors supplied on Marley towers meet rigorous specifications developed from environmental chamber tests at our Development Center These specifications represent prudent minimum design requirements Unless otherwise specified motors provided on Marley cooling towers are TEFC 1 0 or 1 15 service factor appropriate to the applied load 1800 RPM Other enclosures Such as Explosion Proof and motors specially wound for non standard voltages are available at extra cost Two speed motors are also available and their advantages are discussed on page 22 Cold Water Collection Basins If you plan to locate your tower above grade a treated Douglas fir Marley cold water collection basin is available complete with the necessary operating accessories The basin floor is exterior grade pressure treated fir plywood Supported on joists Basin sides are plywood machined to fit the basin floor providing a water tight joint after sealing The standard wood basin includes at least one depressed side outlet sump The number and size of sumps depends on the circulating water rate and the overall size of the tower Unless otherwise specified sumps include plugged drains and hot dip galvanized debris screens Standard sumps are FRP construction or hot dip galvanized steel depending on outlet size Stainless steel sumps and screens are available as options at extra cost Each basin includes an overflow cleanout connection consisting of a galv
4. on Marley right angle Geareducer units TEFC 1 15 service factor motors and heavy duty mechanical equipment supports assure long service life with minimal maintenance All Season Reliability Sigma towers perform as specified in the heat of summer They respond well to energy management techniques in the spring and fall They operate virtually ice free in the dead of winter And they offer simple maintenance all year long We guarantee it Single Source Parts Availability SPX designs manufactures guarantees and stocks all major components of the Sigma cooling tower except motors We ll have the parts if you ever need them Construction and Components Fill Louvers Drift Eliminators Marley high performance film fill is the heart of every Sigma tower A repeating chevron pattern provides the wetted surface and air turbulence necessary for proper heat transfer while minimizing resistance to airflow so you ll save on fan power Molded protrusions on each fill sheet assure uniform spacing Fill sheets are vacuum formed 15 mil 015 thick polyvinyl chloride PVC capable of service at hot water temperatures up to 125 F Stainless steel structural tubes resting in stainless steel hangers support the fill and PVC tubes control alignment Series 1000 fill includes two stainless supports and Series 1200 fill uses four stainless supports This system also holds the bottom of the fill sheets above the cold water basin floor to
5. simplify basin cleaning Fill sheets include both louvers and drift eliminators The louvers in this patented arrangement keep water on the fill sheets and in your tower and also assure proper heat transfer throughout wide variations in airflow Users find this fill operates ice free even in extremely cold weather Integral drift eliminators prevent the costly nuisance of drift spotting on objects in the surrounding environment Their unique shape induces the air flow through three distinct direction changes as illustrated above The final turn directs air toward the fan to save you fan horsepower Moisture carried in the air stream can t make these abrupt turns so drift is 0 010 or less of the circulating water flow rate Mechanical Equipment You ll receive a 5 year warranty against failure of any mechanical component in the fan drive system except the motor which is warranted by its manufacturer The Marley Geareducer speed reducers used in the Sigma line contribute a long record of dependability long service life and low maintenance to this assurance of reliability Their designs meet or exceed the requirements of CTI STD 111 and AGMA Std 420 04 We run in every Geareducer unit under load prior to shipment to make sure that it will operate properly on your tower Housings are gray cast iron Gears are high strength case hardened alloy steel And all bearings are tapered roller bearings A variety of available hor
6. through the Sigma galvanized crossover pipe Inlet connections for your piping are standard 125 flanges Marley flow control valves balance the flow to both distribution basins of each cell Water flows from each valve through a splash suppression chamber into the treated fir plywood distribution basin Polypropylene patented Spiral Target nozzles in the basin floor then distribute the water uniformly over the fill All materials in the water distribution system offer long life and minimal maintenance Valves consist of cast iron bodies and grease lubricated stainless steel operating stems All plywood is treated exterior grade The nozzles are chemically and biologically inert so they ll last indefinitely Structure and Materials Sigma tower design conforms to the latest edition of the National Design Specification for Wood Construction NDS oublished by the National Forest Products Association Wind load criterion is normally 30 pounds per square foot of projected area and the design meets 5 g seismic loading based on a maximum water temperature of 120 F Pressure treated Douglas Fir is the standard material for structural members in Sigma towers because it offers predictably consistent structural strength and provides long service life in cooling towers Treated redwood structure is available as an option However you will benefit in the long run from specifying redwood very selectively and very car
7. towers have doors in both endwalls plus accessways through any and all partition walls Removable fan guards on Series 1000 models keep personnel away from operating fans The galvanized heavy gauge welded rod guards lift off for easy access to Construction and Components the mechanical equipment The taller fan cylinders used on Series 1200 models effectively keep personnel away from the fan eliminating the need for guards All mechanical equipment is accessible both from the interior of the tower and through the fan cylinder Every component of every tower is removable and replaceable Casing Tower endwalls are cased with gray 8 oz sq ft rib type fiber reinforced polyester sheets Water and corrosion proof EH LINKS j FRP is immune to biological deterioration and requires no maintenance Casing ribs run vertically Vertical joints between sheets are overlapped one rib and are sealed in the fill areas Casing attaches to the structural members with stainless steel fasteners and neoprene bonded washers Corner trim pieces are 12 oz sq ft molded FRP Cold Water Collection Basin Most Sigma owners install their towers over concrete cold water basins provided by others However you can choose a Marley wood collection basin as an optional accessory See page 11 Consult your Marley sales representative for detailed dimensioned drawings and load schedules to help you with your basin design Available Optio
8. anized full coupling and standpipe The normally installed standpipe ensures adequate freeboard in the cold water basin and removes easily for flush out basin cleaning A float operated mechanical make up valve provided with each basin automatically replenishes water lost from the system The valve is located in the plenum chamber between fill banks just inside the endwall access door to facilitate adjustment and maintenance 11 Special Component Options High Design Loadings Our engineers will make sure that your Sigma tower will withstand any higher than normal design loadings wind earthquake decking etc that you may specify Clearly define any special design requirements in your tower specifications We ll make any necessary changes to the tower s structural design This is equally true if you anticipate incoming hot water temperatures above 120 F The specification should also describe the type of load system served by the tower and include the expected water quality analysis so that our engineers can select and recommend appropriate changes in component materials to assure satisfactory service Discuss any questions about technical requirements with your trained Marley sales representative Additional Services SPX Cooling Technologies is dedicated to satisfying the needs of our customers needs which begin far in advance of the actual purchase of a new Marley cooling tower and vary over the operati
9. d applied to maximize fan performance Cylinder height varies from 3 5 to 7 O depending on fan diameter Cylinders less than 6 O tall include galvanized welded fan guards See Access and Safety on page 7 Marley manufactured driveshafts transmit power from the motor to the Geareducer assembly All Marley driveshafts include 304 stainless steel tubes with welded on stainless steel flanges and bonded neoprene flexible elements to transmit torque Marley driveshafts are full floating assemblies with non lubricated flexible couplings on each end Their tolerance to misalignment and torsional shock is unequalled in nonspecialized units All Marley driveshafts are dynamically balanced at the factory to minimize operating vibrations Welded unitized hot dip galvanized steel supports maintain alignment throughout the mechanical equipment system Marley torque tubes provide superior strength and stability Their cylindrical shape also keeps operating costs down by minimizing airflow restrictions and reducing air turbulence in the fan entrance region Construction and Components Water Distribution System The gravity flow water distribution system designed into the Sigma tower essentially reduces pump head to its most basic component static lift saving you money on pump power You won t have to force water through internal piping and pressure spray nozzles as you would in a counterflow tower Warm water enters the system
10. de many years of service with minimal maintenance Series 1200 Cross Section o o o o o o o o o o oo Series 1000 Cross Section Guaranteed Performance Don t rely on outside agencies with limited enforcement powers We ll stand by our responsibility for reliable thermal performance We designed it We rate it We guarantee it Exclusive 5 Year Mechanical Warranty Your no cost assurance of trouble free mechanical operation for 5 years Isn t that where a lot of your tower maintenance dollars have gone in the past Long Service Life We ve carefully chosen all the materials used in Sigma towers for their corrosion resistance and suitability for cooling tower service Pressure treated lumber heavy galvanized steel stainless steel PVC and fiberglass keep your Sigma tower working year after year Efficient Field Assembly Precise factory fabrication assures that every component in your Sigma tower will fit as designed And SPX Cooling Technologies offers an unparalleled nationwide construction organization to build your tower quickly and economically Sigma Advantage Low Operating Costs Marley s high efficiency fill and fans gravity flow water distribution and efficient Geareducer drive work together to offer maximum cooling with minimum power use Low Maintenance Costs Induced draft propeller fans
11. e optional However OSHA requires guardrails if the walkway is 4 O or more above the basin floor Used when tower is elevated appreciably above working level Extensions attach to the normal ladder and may require base anchorage depending on length Choose from several corrosion resistant hardware options providing different degrees of protection Sprinkler systems and overlay materials let you choose from a range of fire protection options See page 10 You can choose redwood instead of Douglas fir Distribution Basin or for any or all of these tower elements Tower Structure Cell Partition Options Every Sigma tower includes plenum chamber partitions and hot water distribution basin partitions between adjacent cells Plenum partitions ensure consistent thermal performance as you shut off one fan at a time They keep air from entering an operating cell through an adjacent idle fan maintaining efficient thermal performance Basin partitions let you inspect and clean individual basins while the rest of the tower continues to operate Specify extra partitions carefully because excess partitions can sometimes discourage routine maintenance and good housekeeping procedures Two options are available to meet specific design goals e Fill area partitions are available but usually not necessary The solid sheet design of film fill prevents water and air migration between the fill areas of adjacent cells regardless of operat
12. efully Unless otherwise specified all lumber regardless of species is pressure treated after fabrication Lumber treatment is CCA infused into the wood by the full cell process to 0 40 lb ft retention The primary structural elements of all Sigma towers are the 4 x 4 columns Column bent lines occur on 4 0 longitudinal centers The 4 x 4 tower diagonals carry loads to heavy duty hot dip galvanized steel anchor plates or hot dip galvanized anchor weldments The system of longitudinal and transverse diagonal bracing provides stability in a true tension compression design All structural framing connections use 1 2 dia galvanized machine bolts with either fiber reinforced nylon shear connectors or FRP connector straps The fan deck is pressure treated exterior grade fir plywood designed for a uniform live load of 60 psf Access and Safety The Sigma tower is designed to meet all OSHA requirements A 3 6 high guardrail system complete with toprails intermediate rails and toeboards surrounds the entire top perimeter of the tower Aluminum ladders attached to the tower endwalls provide access to the fan deck level Ladders begin at the cold water basin level and end at the top of the guarddrail Each tower normally includes two ladders one at each endwall Hinged doors through the endwall casing permit access to the interior of the tower at the basin level Single cell towers have one door Multicell
13. ice can return your tower to as new condition Performance Improvement Service Systems served by cooling towers grow in response to demand for the product produced by that system Most customers find that they could produce more product if the cooling tower could deliver colder water Fortunately cooling tower technology advances with time and we can ap ply this increased technology to upgrade your tower s thermal performance Tower Replacement Service Occasionally customers will benefit from replacing an installed tower rather than refurbishing it SPX Cooling Technologies stands ready to assist you in that endeavor and in most cases the replacement will require little or no change to your concrete basin or support structure SP COOLING TECHNOLOGIES 7401 WEST 129 STREET OVERLAND PARK KANSAS 66213 UNITED STATES 913 664 7400 spxcooling spx com spxcooling com In the interest of technological progress all products are subject to design and or material change without notice 2008 SPX Cooling Technologies Inc Printed in USA SIG 07
14. ing mode e Complete watertight partitions provide total cell isolation These partitions let you use adjacent cells to serve separate loads with incompatible system temperatures Watertight partitions extend from louver face to louver face and cover the full internal height of the tower including the cold water basin Partitions usually consist of exterior grade pressure treated fir plywood sealed to cold water basin partitions made from the same material as the basin sides For concrete basin partitions design drawings are available that specify the appropriate Marley dimensions Optional weir gates in wood basin partitions let you mix or segregate the water in the basin to meet your operating needs Marley weir gates come with removable cover plates Available Options Wood Stairway with Access Platform Oil Level Sight Glass Special Component Options Fire Protection Options The PVC fill louvers and drift eliminators used on Sigma towers are fire retardant having flame spread ratings less than 25 per ASTM E 84 Standard fan decking material is pressure treated fir plywood which ignites poorly and burns slowly For these reasons governing agencies Such as Factory Mutual may not require fire protection sprinkler systems on Sigma towers On specific jobs you may want to weigh the cost of various modifications against the cost and maintenance of a sprinkler system or the cost of higher insurance premi
15. ng lifetime of the project Here is a partial listing of the additional services offered by SPX Cooling Technologies to help you do your job most effectively Application Sizing Layout Services Sales Engineers are trained to help you choose the proper type and size of cooling tower and will guide you in its appropri ate location on site They will also help you write the specifications for its purchase As the only manufacturer who makes all types of cooling products SPX Cooling Technologies can offer you a wide range of options to meet your requirements Construction Service We can supply supervision only or a complete experienced crew to handle construction Parts Service We maintain a stock of spare parts specific to your Marley tower Maintenance Service lIn addition to providing complete instructions and continuing guidance we will provide as much hands on maintenance as you require or will recommend a local service contractor for your consider ation Condition Inspection Service From time to time for your peace of mind our engineers can give your tower a thorough inspection to evaluate its current condition This usually allows you to foresee and forestall problems before they become serious Reconstruction Service Due to operating or atmospheric conditions or age sooner or later your tower will be in need of repairs above and beyond those categorized as normal maintenance Our reconstruction serv
16. ns Accessory Plywood Cold Water Collection Basin Bottom Outlet Sump Extended Columns for Deep Collection Basin Fan Cylinder Extensions Cell Partitions Vibration Limit Switch Oil Level Sight Glass Air Inlet Screens Plywood Distribution Basin Covers Description and Remarks Pressure treated Douglas fir plywood collection basin for towers located above grade See page 11 Square plan galvanized steel sump with bottom outlet Outlet connection is a hole and bolt circle conforming to 125 ASME pipe connection Includes a plugged drain connection in sump bottom Interior tower columns can be extended to permit concrete basin depth of up to 5 6 Some exceptions apply so consult your Marley sales representative Optional flared fan cylinder extensions improve fan efficiency to reduce your operating costs Extensions on Sigma 1000 Series towers conform to OSHA requirements without fan guards Extra partitions between fan cells for specific operating considerations See page 9 Robertshaw or Metrix single pole double throw vibration switches in NEMA 4 housing Double pole double throw models are also available A brass fitted oil level sight glass takes the place of the dip stick on the external oil fill and drain system Permits easy reading of oil level and also lets you change oil through the lube line Galvanized wire mesh screens over the air inlets keep leaves and trash out of the tower
17. sepower capacities and reduction ratios lets us choose the optimum Geareducer model and fan speed for your job Service factors are always at least 2 0 as applied Splash type lubrication and integral cooling fins preclude the need for maintenance intensive oil pumps and coolers A constant oil bath or flow lubricates every bearing in forward or reverse motion at full or half soeed All Marley Geareducer assemblies are right angle type with motors located outside the tower s saturated airstream A galvanized steel lube line runs from the Geareducer unit to a Standpipe near the motor on each cell so you can check oil level and change or add oil while standing on the fan deck All Sigma Series 1000 1200 towers offer the benefits of adjustable pitch propeller tyoe Marley fans The H 3 series fans normally used on smaller models incorporate cast aluminum blades and machined aluminum hubs HP 7 series Construction and Components fans used on larger models include hollow GRE glass reinforced epoxy blades and epoxy coated cast iron hubs Blades on both fan types are adjustable in pitch so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual job site restrictions The true airfoil blades designed specifically for cooling towers offer efficient quiet operation and long service life Fans operate inside structural GRP glass reinforced polyester eased inlet fan cylinders designed an
18. ums One or more of the following tower modifications may negate the need for a sprinkler system e Fire retardant fan cylinders and optional casing offer flame spread less than 25 per ASTM E 84 e A 1 4 thick fiber reinforced cement board FRC overlay on the fan deck acts as a fire stop and provides a nonskid walking surface e A 1 4 FRC overlay on the distribution basin covers acts as a fire stop e Barrier walls keep fire from spreading between cells in multicell towers Specify barrier wall design by containment period such as a 20 minute fire wall Barrier walls are full width full height of the tower interior except cold water basin and consist of oressure treated fir plywood both sides of the column line between cells Plywood thickness and cost vary according to the specified containment time e Steel construction Remember that the Sigma series is available in steel construction either galvanized or stainless as are a number of other Marley series all of which meet all established fire code requirements If your insurance carrier insists on a sprinkler system for your tower consult your Marley sales representative We can orovide a sprinkler system to fit your needs or work with your people to be sure that the sprinkler system and tower will meet your specification 10 Non Standard Motors Although you can buy your Sigma tower less motor at a cost reduction it is not normally recommended
Download Pdf Manuals
Related Search
Related Contents
6 - Drivista ダウンロード(PDF 0.69MB) Butler 4056/4056C TELEVIZOR LED(FULL HD) 22” CU PLAYER DVD Sanyo LNS-T21 Mode d`emploi - Roland Central Europe Samsung UE22ES5400W JVC RD-EZ15 3G/GPS トラッカー 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file