Contents
1. SMS command messages intended for getting parameter configuration of each input output 1 8 The GB 051 unit will return sender a message with the required configuration information related to the particular IO e Actual value of logical level of the particular input Pre set phone number for ALARM call Pre set number A for ALARM SMS for the particular input Pre set SMSNO B for the input Pre set SMSTXT text of the message of the input IO value acall aSMSnoA aSMSnoB SMStxt In case the command SMS message is sent with no parameter the GB 051 unit will respond to the sender with message containing five basic configuration data infoSMS number infoSMS interval icall number icall interval mcall number 4 12 CALLBACK Monitoring of Protected Area If you want to find out by listening e g during alarm what is happening in place of installation it is possible to require by SMS message to get further call from GB 051 with switched on microphone for room monitoring Command XXppppCALLBACKVnumber pppp Four digits of current PIN Number Maximum 14 digits of any phone number 7 1 The space is between key word of command CALLBACK and number 2 If no number is specified GB 051 calls back the number of sender of SMS command Number can be entered in national format e g 606445566 but also in international format e g 420606445566 16 5 The call will take 25
2. 4 6 ACALL Automatic Alarm Calling By activation of any of SMS inputs set phone number is automatically chosen together with sending SMS message Dispatched SMS message can be highlighted if you set ACALL number identical to SMSNO number or you can report alarm on fixed phone lines where SMS messages cannot be received After answering warning tone is generated into speaking line Command XXppppACALLiVnumber Pppp Four digits of current PIN i Number of input 1 to 8 Number Maximum 14 digits of number of any phone which allows display of caller s number 1 The space is between key word of command ACALLI and number 2 Number can be entered in national format e g 606445566 but also in international format e g 420606445566 No number is activated from production If you want to deactivate this function set command without parameter tm XXppppACALLi without further parameters 4 7 INFOSMS Sending of Information Messages about Operation GB 051 allows set up of one cell phone number where all information SMS messages about change of PIN reset initialization power supply failure change in configuration operation time and input activation are subsequently sent Command XXppppINFOSMSVnumber no number activated from production Pppp Four digits of current PIN Number Maximum 14 digits of cell phone number 7 1 The space is between key word of command I
3. GSM REMOTE SUPERVISION GB 051 Set for cellular phone Siemens C35i M35 or S35 Automatic Information Transfer over the GSM Network USER GUIDE SS LEVEL Dear Customers We would like to congratulate you on purchasing our product GSM Remote Supervision GB 051 This way you are getting a high class and technically highly modern product GSM Remote Supervision GB 051 allows first class and highly effective protection of cars or properties It provides protection which cannot be easily disabled by cutting the phone line protection which sends an ALARM message within 3 seconds and which allows also continuous control of protected area Information about disturbance is sent in a form of phone call with warning signal or in a form of SMS message to your cell phone or by fax even by e mail if required GB 051 also allows monitoring of protected area and remote control of household appliances by cell phone or by e mail Cell phone connected to GB 051 can be used simultaneously for outgoing and incoming calls without restriction of the unit s security function Thanks to high reliability of information transfer and low purchasing and operation costs GB 051 can be used also for transmission of technological information GB 051 is universal communication device which can be configured by PC or cell phone to carry out requested functions handling during operation is easy Before setting Remote Supervision GB 051 into operation plea
4. mail level levelna cz www levelna cz 24
5. not place GSM Remote Supervision or aerial mast close to phone exchange or other electronic devices or lines Due to high frequency electromagnetic field these devices could be interfered Due to interference it is not advisable to operate device close to other power or high frequency devices Before assembly prove by cell phone if there is sufficient level of signal required by GSM network in selected place Pay attention to delay in indicating of signal level When using for protection of property arrange protection of area against break in by detector 3 2 Wiring and connecting the GSM Remote Supervision unit Top view Connector description 1 input output No 12345678910 2 input output No 3 input output No 4 input output No 5 input output No 6 input output No 7 ground 8 input output No 7 9 input output No 8 10 power supply 12 V Bottom view Connector description Init Ground Reset TxD RxD Ucc OORUN 123456 OOT GON RESET By connection clips no 2 and 3 ground and reset the unit reset will be run while all the set configuration value will remain in place The value of days in service will be set to 0 INIT Detailed description of how to carry on the initialization can be found in Chapter 4 1 The GSM Remote Control device will be set into default manufacturer s settings by the initialization Recommended linkage of outputs Rec
6. of current PIN GSM Remote Supervision will be set to initial set up from production Sender of Command receives message about correct reception of Command In case you do not know pre set PIN or you are not able to program for another reason then carry out hardware initialization described in chapter 4 1 ICALL Regular Calling Free of Charge If you want to be informed free of charge about correct function of GB 051 in set regular intervals following parameters provide it Command XXppppICALLVnumber Pppp Four digits of current PIN Number Maximum 14 digits of number of any phone which allows display of caller s number 1 The space is between key word of command ICALL and value of parameter number 2 Number can be entered in national format e g 606445566 but also in international format e g 420606445566 Command XXppppICALLINTVh Pppp Four digits of current PIN H Length of intervals in hours time interval of two successive calls Value from 1 to 240 hours can be set 168 hours set from production 1 The space is between key word of command ICALLINT and value of parameter h After set up of these parameters calling to set number will be automatically activated Phone rings only 5s and does not await pick up This way record about calling from GB 051 is entered on display of cell phone without any charges unless called
7. on the lower side of the box is intended for connecting a mobile phone Siemens one of those C35i M35 S35 There is also a connector for data cable for connection to a PC that enables comfortable set up of required configuration data All configuration parameters can also be set using SMS messages sent from a mobile phone or Internet Red light emitting diode LED on the left side signalizes basic operational states e g correct function function from backup power supply GSM connection in ready mode action in progress etc It is possible to prepare separate text of SMS message and to specify two numbers of cell phones to which message shall be sent for each of the 8 inputs Prepared text of SMS message is sent to specified numbers by activation of one of the 8 inputs and phone call with warning alarm signal is carried out to a predefined number In case it is not possible to send SMS message or call the attempt is repeated 10 times in the intervals of 5 minutes Each input can be used at the same time as output and it is possible to set up reguested value of inputs using SMS message sent from cell phone or Internet It is possible to reguest call with additional sound monitoring of the room by incoming SMS message It is still possible to use cell phone connected to GB 051 to carry out outgoing and incoming calls GB 051 is self controlled it sends information about failure of power supply messages about reset initializat
8. over of completely filled in Guarantee Certificate and hand over of device intended for repair including equipment 21 STATEMENT OF CONSENSUS We LEVEL Ltd Plhovska 1997 547 01 Nachod Registration No 47469374 V A T No 243 47469374 declare hereby our exclusive responsibility that hereinafter mentioned product meets requirements of technical regulations that product is save when used on specified conditions and that we took all actions which ensure consensus of all products of hereinafter mentioned type placed on the market with technical documentation and with requirements of relevant government regulation Product Remote Supervision Type GB 051 010 Product is designed for telecommunication purposes Way of consensus judging 12 4 a of law No 22 1997 of Col Above mentioned product is conformable with 8 of law No 22 1997 of Col and government regulation No 169 1997 of Col and standards for electromagnetic compatibility CSN 342895 CSN EN 55 022class B and government regulation for electrical safety No 168 1997 of Col Additional information Power supply is carried out by safe voltage of 10 16 V direct current Device is compatible only with cell phone Siemens C35 M35 and S35 Released in Nachod Name Ing Michal Falta Date of release 01 08 2003 Function Managing Director Stamp and signature 22 23 GB 051 1 02 LEVEL 2003 LEVEL Ltd Plhovska 1997 Nachod 547 01 CZECH REPUBLIC E
9. 5 seconds unless you end it sooner by hang up Sensitivity of cell phone built in microphone might be relatively low Therefore it is necessary to select a suitable placement of the unit in order to use this feature Programming from PC Comfortable way of setting of all GB 051 parameters from PC by the means of configuration program and serial cable with converter can be used Program and cable can be bought additionally as set for configuration from PC supply No ED 051 011 Program shall be installed under MS WINDOWS by command Axsetup Connect GB 051 through interconnecting cable with converter ED 051 011 Program allows reading of actual configuration from GB 051 changing of configuration and exporting of new configuration into GB 051 Configuration can also be saved and read from files Operation during Failure of External Power Supply During failure of external power supply GB 051 operates with unchanged output for approx 12 hours from battery However it is not able to switch on the cell phone without external power supply and therefore command RESET is ignored Configuration which you enter in GB 051 will be saved in memory type EEPROM for arbitrarily long time even during disconnection or total discharge of backup battery 7 List of Programming Commands Control SMS Messages Command XXpppp Without no calls back Description 4 Range Set Set PI
10. N PINVNNNN nnnn 4 digits of PIN 0000 RESET of GSM Supervision RESET 3 Initialisation of parameters INIT M Regular information calling ICALLVn n max 14 digits 5 Length of interval of calling ICALLINTVh h 1 240 hours 168 Monthly calling MCALLVh n max 14 digits Alarm calling ACALLIVN n max 14 digits M Information number INFOSMSVAn n max 14 digits Interval of sending information SMSINTVn n 1 255 days 7 SMS messages Alarm SMS messages SMSTXT1V text text of 4 144 digits put in ALARM1 SMSTXT2V text a ALARM2 SMSTXT8V text ALARM3 SMSTXT4V text ALARM4 SMSTXTS5V text ALARM5 SMSTXTE6V text ALARM6 SMSTXT7V text ALARM7 SMSTXT8V text ALARM8 Numbers for 101 SMS nA SMSNOA1Vn n max 14 digits sending 101 SMS n B SMSNOB1Vn ALARM SMS 102 SMS nA SMSNOA2Vn messages 102 SMS nB SMSNOB2Vn 103 SMS nA SMSNOA3Vn 103 SMS nB SMSNOB3Vn 104 SMS nA SMSNOA4Vn 104 SMS nB SMSNOB4Vn 105 SMS nA SMSNOA5Vn 105 SMS nB SMSNOB5Vn 106 SMS nA SMSNOA6Vn 106 SMS nB SMSNOB6Vn IO7 SMS nA SMSNOA7Vn 107 SMS nB SMSNOB7Vn 108 SMS nA SMSNOA8Vn 108 SMS nB SMSNOB8Vn Set output No 1 terminal No 1 OUT1W y 0 output in logical 1 Set output No 2 terminal No 2 OUT2W value 0 1 Set output No 3 terminal No 3 OUT3W y 1 output in logical 1 Set output No 4 terminal No 4 OUT4W value 1 1 Set output No 5 terminal No 5 OUT5W without y logical value 1 Set output No 6 terminal
11. NFOSMS and number 2 Number can be entered in national format e g 606445566 but also in international format e g 420606445566 13 4 8 4 9 If you want to deactivate this function set command without parameter tm XXppppINFOSMS without further parameters SMSINT Interval for Dispatch of SMS Messages about Operation Interval for sending regular SMS messages to INFOSMS number which include time of operation can be set Command XXppppSMSINTVn interval of one day is set from production pppp Four digits of current PIN Number Number from 1 to 30 It is interval for sending successive message about operation 1 The space is between key word of command SMSINT and value of parameter n ALARMSMS Alarm SMS Messages When one of 8 inputs is activated GB 051 allows in addition to phone call to common ACALL number also sending one of 8 prepared texts of SMS message to two cell phone numbers Change of texts of SMS messages p Order on the Command Initial set up Input terminal board XXppppSMSTXT1V text ALARM1 101 1 XXPPPPSMSTXTAV text ALARM2 102 2 XXPPPPSMSTXTAV text ALARM3 103 3 XXppppSMSTXTA4V text ALARM4 104 4 XXppppSMSTXT5V text ALARM5 105 5 XXppppSMSTXT6V text ALARM6 106 6 XXppppSMSTXT7V text ALARM7 107 8 XXPPPPSMSTXTAV text ALARM8 108 9 PPPP Four digits of current PIN text 4 144 digits always put
12. No 6 OUT6W 0 1 Set output No 7 terminal No 8 OUT7W 1 Set output No 8 terminal No 9 OUT8W 1 Find out set up LISTVn n input No 1 to 8 7 Without n returns common set up Call with monitoring CALLBACKVn n max 14 digits 1 Always start with text XXpppp where pppp is PIN of GB 051 18 Basic Technical Parameters GB 051 ALARM tone 400 Hz Inputs of SMS messages No 1 8 Logical 0 0 0 5 V Logical 1 4 6 V Outputs of SMS messages No 1 8 Logical 0 max 08V forlz 5mA Logical 1 3 5 4 5 V for Iz 0 03 mA GSM network GSM 900 1800 MHz SIM card Plug in Device Power supply voltage 10 16 VDC Peak power consumption during charging 350 mA for 12 V Max time of charging 4 hours Power consumption with charged battery lt 20 mA Time of operation from backup battery Min 12 hours Size 65 x 70 x 17mm Weight 50 g Operational temperatures from 5 to 40 C GUARANTEE CERTIFICATE Product NAME 00 eee eeeeeeeeeesteeeneeeeeees MYC aerea a i Production number n se Daterof sale 1 02c6023111 nora thee Signature ooroon nr Seller stamp oooooooo non non Information about guarantee repairs Date of Date of Signature Description of defect receipt return Producer LEVEL ltd Plhovsk 1997 547 01 N chod Czech Rep Tel Fax No 420 491 44 66 11 e mail
13. about Operation 13 4 8 SMSINT Interval for Dispatch of SMS Messages about Operation 14 4 9 ALARMSMS Alarm SMS Messages oooooonnnnncnn iu rn 14 4 10 OUT Set up of Level of Outputs by SMS messages sooonoriim 15 4 11 LIST Detection of Set Up oooonnnonn nosne rn 16 4 12 CALLBACK Monitoring of Protected Area oooonnnornn nic rr 16 5 Programming from PO 2 aise na a van idu a 17 6 Operation during Failure of External Power Supply oooonos nnnnvnn rn 17 7 List of Programming Commands Control SMS Messages 18 8 Basic Technical Parameters oooososnvnnoce te on rn 19 GUARANTEE CERTIFICATE raen anaa o seeeeeenaaes 20 GUARANTEE CONDITIONG ccecceeeeeeeeeeeee Rn nn 21 STATEMENT OF CONSENSUS oooon iron niek kn nn 22 1 Product Description 1 1 Description of Function GSM Remote Supervision GB 051 consists of plastic box which is firmly joined to the battery of cell phone Communication cable with connector gets out of this box into cell phone which is used by GB 051 for realization of phone connection and reception and sending of SMS messages On the upper side of the box there is a cut off terminal board with terminals for power supply for interface to PC control inputs and 8 input output cables to alarm switchboard to detectors or to switching electronics Cable with a connector
14. ent is 500mA While cover is removed parts under voltage can be exposed Device must be disconnected from all power sources including backup battery before maintenance or exchange of parts or filled boards While fitting together and assembling the equipment avoid cut off of interconnecting cables or their damage by edges No fluids must enter the device Danger of fire destruction of device or injury by electric current impend In case it occurs pull power source out of the plug immediately and consult specialist Avoid forceful mechanic stress of device Do not place device into rooms with high temperatures strong vibrations or high humidity In case you moved device from cool to warm room do not set it into operation immediately Water condenses on device and operation under these circumstances can cause damage of device Let device warm up to temperature of room Wait until condensed water evaporates The GB 051 unit must be stocked always with the mobile phone connector disconnected when disconnected from external power supply the GB 051 is supplied from the mobile phone battery and the battery can be damaged by getting completely flat 3 Installation and Setting into Operation 3 1 Assembly of GSM Remote Supervision GSM Remote Supervision by LEVEL is designed for operation in dry places During assembly avoid hot places and places where device would be exposed to direct solar radiation or places close to heating elements Do
15. h includes in text XXppppINSTRUCTIONWparameter XX Two capital letters X pppp Four digits of current PIN in GSM Remote Supervision INSTRUCTION Key word of the command no difference with capital or small letters v Space follows parameter Set up value End of seguence by space or end of SMS message One SMS can include up to 4 commands The message then can look like this XXppppCOMMAND1Vparameter 1VCOMMAND2 Vparameter2VCOMMAND3 parameter8V A confirming message is sent to the number the command message came from this message includes information about the new set parameter value 4 1 PIN in GSM Remote Supervision So as GSM Remote Supervision works correctly it is necessary that PIN on SIM card corresponds with PIN of GSM gate and is different from 0000 In phone menu SIM card must be blocked tm control of PIN after switch on must be activated If the SIM card is blocked by a PIN code connect the GB 051 to the mobile phone only after the PIN in GB 051 was set to the same value otherwise there is a great risk of the SIM card getting blocked Change of PIN Command XXppppPINVnannn pppp Four digits of current PIN in GSM Remote Supervision nnnn Four digits of new PIN Space must be between the key word of command PIN and value of parameter nnnn GB 051 confirms reception of Command to sender and draws his attention to necessity of correspondence of PIN i
16. in quotes guestion 1 The space is between key word of command SMSTXT and text Change of numbers for sending ALARM SMS messages Text of SMS message No 1 2 3 4 5 6 7 or 8 will be sent by activation of input No 1 2 3 4 5 6 7 or 8 by connection with terminal No 7 ground on terminal board of GB 051 Each prepared text of SMS message of particular input can be sent to two cell phone numbers No number is activated from production These numbers can be set Activated by input Order on the commana No terminal board XXppppSMSNOA1Vnumber 101 1 XXppppSMSNOB1Vnumber 101 1 XXppppSMSNOA2Vnumber 102 2 XXppppSMSNOB2Vnumber 102 2 XXppppSMSNOA3Vnumber 103 3 XXppppSMSNOB3Vnumber 103 3 XXppppSMSNOA4Vnumber 104 4 XXppppSMSNOB4Vnumber 104 4 XXppppSMSNOA5Vnumber 105 5 XXppppSMSNOB5Vnumber 105 5 XXppppSMSNOA6Vnumber 106 6 XXppppSMSNOB6Vnumber 106 6 XXppppSMSNOB7Vnumber IO7 8 XXppppSMSNOB7Vnumber IO7 8 XXppppSMSNOB Vnumber 108 9 XXppppSMSNOB8Vnumber 108 9 pppp Four digits of current PIN Number Maximum 14 digits of cell phone number 1 The space is between key word of command and number 2 Number can be entered in national format e g 606445566 but also in international format e g 420606445566 If you want to deactivate the number set command without number tm e g XXppppSMSNOAS3 without further parameters 4 10 OUT Set up of Level of Outputs by SMS mes
17. in the GB 051 and the SIM card for security reasons This will also verify the correct functionality of the GB 051 device by confirming it can receive the command SMS and set reply message back After the inguiry on the phone display enter PIN with phone keyboard and wait until phone logs in From this moment GSM Remote Supervision is able to accept control SMS messages Therefore send control message command to cell phone connected to GB 051 XX0000PINVpppp Where XX means two capital letters X 0000 is the current PIN in GB 051 manufacturer setting is 0000 PIN is the key word of the command v is the space symbol pppp is the new PIN value 4 3 4 If the PIN code on the SIM card is the same as the PIN in GB 051 and SIM is blocked by PIN then after setting new PIN to the GB 051 unit the PIN will be changed in both the SIM and GB 051 unit GB 051 replies to this SMS message and draws sender s attention to necessity of unification of PIN in Remote Supervision and phone and to necessity of switch off of cell phone After reception of this SMS message verify correct PIN code change by switching the phone off with the red phone button If PIN is set correctly and external power supply is connected GB 051 automatically switches on the phone sets PIN and LED starts to flash in slow rhythm It signalizes readiness of Remote Supervision for reception and sending messages At the same time new PIN is entered into memo
18. ion about configuration change but also information messages about operation in set intervals 1 2 Contents of Delivery Sets ellela SA ASAJASA ES Label Component description ip 5 ip o 8 6 8 o 9 GB 051 010 GSM Remote Control only e o GB 051 011 GSM Remote Control with the Siemens C35i mobile phone ele SA 012 602 AC DC Adapter 220 V 12 V DC 600 mA cable 1 5 m long e Connector e o o 13 004 027 Siemens C35i mobile phone only o lo 13 004 028 External FME antenna reduction cable for the Sg lea ie Siemens C35i mobile phone ED 001 001 External 3 dB antenna with magnet 3 meter cable ED 001 002 Flat external antenna to be glued on glass or plastic Converter for connection between a PC and the GB ala att 051 k PC configuration software included SE Ns ED 051 050 Connector reduction for the ED 050 001 converter olo lo lo 01 002 008 NiMH battery for the Siemens C35i mobile phone olo lo lo ED 050 300 Double power switch 230 V 5 A olo lo lo ED 050 400 Motion detector olo lo lo ED 050 401 Motion detector with remote control olo lo lo ED 060 601 Push button connectable into a panel o o o lo e included in the predefined set 0 optional accessory for the product type 2 Safety Commands GB 051 is conformable with technical standards for operation in our mains Power source with voltage 10 16 V DC must be used for power supply Dimension for peak curr
19. level levelna cz www levelna cz 20 GUARANTEE CONDITIONS Length of guarantee period is 24 months from the date of sale Guarantee applies only to goods registered or identified by company LEVEL Guarantee repair will be carried out at latest within 10 working days after receipt of defective goods by company LEVEL provided that spare part is disposable in store If it is not possible alternative solution will be offered to user for time of repair Guarantee repairs will be carried out in company seat Technician is solely responsible for choosing the way of transport Guarantee is not provided in following cases Loss or replacement of Guarantee Certificate or its additional correction Damage of device caused by natural disaster or damage of device during transport Damage caused by unsuitable positioning unsuitable handling operation of device in unsuitable conditions Any unauthorized repair or adjustment carried out on device Damage or removal of sealing labels Guarantee does not apply to expendable property dyeing ribbons floppy discs etc It does not apply to malfunction caused by installed software or interference either Company is not responsible for possible losses which originate from device failure either Guarantee does not apply to malfunction caused by change of external conditions as change in legislation change of phone network change of supply network etc Guarantee is exerted by hand
20. n GSM Remote Supervision and on SIM card of cell phone At the same time advises of necessity of switching off the phone by red key This way new PIN is entered into GSM Remote Supervision memory and connected cell phone is automatically switched on Information about GB 051 reset and change of PIN is sent to INFOSMS number after action is successfully carried out In case the PIN code is the same on the SIM card and in the GB 051 unit and the SIM is blocked by PIN then after entering a new PIN into GB 051 the PIN code on the SIM card will be changed as well 4 2 Value of PIN of GSM gate set from production and after initialization is 0000 PIN 0000 shall not be set into cell phone from gate so that blockage of phone is not caused during first contacts with gate Example Original PIN of GSM gate is 0000 SIM card which you use in cell phone in GSM gate has PIN 1234 and is blocked by PIN Insert the SIM card into the mobile phone but do not connect the GB 051 connector yet Insert the required PIN in the mobile phone e g 1234 Go into the mobile phone menu and select Settings Security Codes Change PIN then insert the old PIN and the new PIN according to the mobile phone instructions Send a command SMS message with text XXOOOOPINV1234 from cell phone or Internet on cell phone number in the unit As soon as a confirmation SMS message comes back to sender s cell phone the new PIN is set to value 1234 User can
21. of the two ways described below a If SIM is not blocked by PIN code then the PIN value in GB 051 is irrelevant in this case you can skip this instruction and continue to assembly the GB 051 and the cell phone b If SIM is blocked by PIN and then the PIN in GB 051 must be the same with the PIN at the SIM in mobile phone The default PIN code in the GB 051 unit is set from production as 0000 This will also be the PIN value after unit s initialization How to change PIN code in the Siemens mobile phones In menu select Setup Security Codes Change PIN and the phone will ask you to enter first the current PIN and then to enter and verify the new PIN code enter PIN 00007 Description of first assembly 1 Insert the SIM card and battery into the cell phone put on the back cover 2 Stick the GB 051 unit together with the back cover of the mobile phone connectors must be faced down 3 Interconnect the GB 051 with connector in the cell phone 4 Connect the 12 V external power supply connector 5 After the power supply is connected the GB 051 will automatically turn on the phone and if the PIN code is reguested by the phone the unit will automatically enter the PIN predefined in configuration 6 Wait to see the cell phone to connect to the GSM network the LED should start blinking slowly 7 Following this it is recommended to send a command SMS as described below to set a new PIN other than 0000
22. ommended linkage of inputs 12V 0 I 101 101 106 BC 517 o 3 3 If GSM signal is insufficient external antenna can be connected to cell phone Professional solution of switching electrical devices on and off is provided by the 230 V 5 A double power switch ED 050 300 that can be purchased as optional accessory For connection with a PC use always the ED 051 011 converter with cable that connects into the connector at the bottom side of the unit and into the RS 232 interface in your PC If you need to connect the PC using the older ED 050 001 converter use the new optional accessory ED 051 050 cable with reduction Control Panel software included The GB 051 device is able to work fully without external power supply for approximately 12 hours being supplied from the mobile phone battery Inserting the SIM Card and Connecting to the Cell Phone GSM Remote Supervision can be used only with cell phones Siemens C35 M35 and S35 Do not attempt to connect other phones it may cause device or phone damage Always use only NiMH battery with the GB 051 Using a Li lon battery might result in unstable function of the GSM Remote Supervision this type of battery can cause the mobile phone to turn off without the possibility of starting up automatically 7 Cell phone must be in basic configuration only parameters specified further can be changed A SIM card inserted in the GB 051 device must be configured in one
23. party picks it up If you want to deactivate this functions set send the command without parameter for example XXppppICALL or XXpppICALLINT without further parameters MCALL Monthly Calling Some GSM operators require requires to carry out at least one paid phone connection in 3 months from this card in order to keep the SIM card working otherwise the prepaid credit might expire In order to prevent this from happening it is possible to enter a number into GB 051 which the unit will automatically call every month of operation the phone call will be hung up 10 seconds after pick up 12 Command XXppppMCALLVnumber Pppp Four digits of current PIN Number Maximum 14 digits of number of any phone 1 The space is between key word of command MCALL and value of parameter h 2 Number can be entered in national format e g 606445566 but also in international format e g 420606445566 No number is activated from production After entering this parameter GB 051 calls set number once a month in order to spend at least one tariff impulse If you want to use this service it is recommended to set up number of your fax or number of time information It is not recommended to set your cell phone number because GB 051 does not use real time and call can come during night If you want to deactivate this function set command without parameter for example XXppppMCALL without further parameters
24. ry of GB 051 It is possible to set up volume of cell phone ringing according to your need in main menu Ringing of the phone can be eventually switched off completely It is possible to change or switch off the sound indicating reception of SMS message either Furthermore volume of conversation can be changed only the volume of speaker is concerned If SMS centre is not correctly set on SIM card it is necessary to set it up in cell phone menu Indication by LED Indicating LED on the side of GB 051 indicates basic operating states Slow regular flashing Remote Supervision is prepared for operation Occasional short flash Remote Supervision is prepared but runs from backup battery 6 quick flashes Action in progress after an input is activated 3 quick flashes Incoming SMS command message Quick flashing Not ready for ALARM no connection to the GSM Programming by SMS Messages Number of functions and parameters which allow adjustment of GSM Remote Supervision to environment and users requirements can be configured by programming At the same time programming allows control of functions by user Programming can be carried out either remote by SMS message from cell phone or Internet if available or comfortably using the Control Panel software and the ED 051 011 communication converter with cable connected to the serial port of your PC Send a control SMS message from cell phone or Internet whic
25. sages Required logical level of outputs No 1 to 8 can be set by incoming SMS message If output is set to logical value 0 it is not possible to activate it as input 1 Order on the fe sr Oui terminal board XXppppOUT1VW 101 1 XXppppOUT2Wy 102 2 XXppppOUT3VWy 103 3 XXppppOUT4W 104 4 XXppppOUT5W 105 5 XXppppOUT6W 106 6 XXppppOUT7Ww 107 8 XXppppOUT8Vy 108 9 PPPP Four digits of current PIN y Figure 0 or 1 determines logical level of output By sending value 0 output is set to OV By sending value 1 output is set to 4 5V 1 The space is between key word of command and value of parameter y All outputs are set to logical level 1 4 5 V from production Inputs can be therefore activated 15 If you only want to change value of output regardless of previous state send command without parameter y e g XXppppOUT5 changes value of output No 5 to reverse Newly set actual values of all 8 inputs outputs are sent back to sender and to INFOSMS number 4 11 LIST Detection of Set up If you want to find out which values of parameters are set in GB 051 it is possible to send control SMS message which initiates sending messages with detailed description of set up back to sender Command XXppppLiSTV PPPP Four digits of current PIN i IO number 1 to 8 with no parameter will return the shared configuration 1 The space is between key word of command LIST and i
26. se read this command manual carefully It will not only introduce you the correct installation and handling of this product but at the same time will help you fully utilize all its technical potentialities TABLE OF CONTENTS GSM Remote Supervision GB 051 12 Product DOSCrPtlON sisters sschegenedeatesgitey rn 4 1 2 Contents of Delivery oooono nn noone cece eeeeeeeeeeeaaeeeseaeeetene seneeeeeeeneees 5 2 Safety Commands nss aa a un on 5 3 Installation and Setting into Operation ooooonn cocn u rnnnnrrnnnn nn 6 3 1 Assembly of GSM Remote Supervision oooororononnvone oernnnnnn nn 6 3 2 Wiring and connecting the GSM Remote Supervision unit 6 3 3 Inserting the SIM Card and Connecting to the Cell Phone 7 3 4 Indication DYLED ssena ino TN a geese ie 9 4 Programming by SMS Messages oooonnnonn iii krrtnnnn nn eee 9 4 1 PIN in GSM Remote Supervision ooroorrnnovnnnnnne nrnnn nn nn 10 4 2 RESET of GSM Remote Superision ooooroonnnnnnnniu onnnnnnnn nn 11 4 3 INIT Re initialization of Values Set from Production 12 4 4 ICALL Regular Calling Free of Charge o ooooon vonnnnie ceeeeeeseeees 12 4 5 MCALL Monthly Calling oo ooooonnnocn noone rn tees 12 4 6 ACALL Automatic Alarm Calling oooonnnnnonnnnic nrronnnnn nn 13 4 7 INFOSMS Sending of Information Messages
27. verify the PIN change by switching the phone off Initialization In case you forget current PIN of GSM Remote Supervision you have no choice than to carry out initialization of parameters to original set up from production It shall be carried out in following steps 1 Disconnect external power supply throw up power adapter 2 Disconnect the mobile phone connector 3 Interconnect inputs GROUND and INIT terminals No 1 and 2 see Chapter 3 2 on terminal board 4 Connect external power supply throw in power adapter 5 Remove connection GROUND INIT 6 Disconnect external power supply throw up power adapter 7 Connect the mobile phone to the GB 051 unit the PIN must be preset to value 00007 8 Connect external power supply 9 PINand other reguired parameters have to be set up again RESET of GSM Remote Supervision If you want to carry out remote reset of counters of days and months in operation then send SMS message with Command RESET Command is rejected if GB 051 runs from backup battery Command XXppppRESET Pppp Four digits of current PIN Function is equivalent to disconnection of gate from power supply also backup one and its re connection 4 3 4 4 4 5 INIT Re initialization of Values Set from Production In case you lost view of GB 051 set up you can carry out remote re initialization of parameter values set in production Command XXppppINIT Pppp Four digits
Download Pdf Manuals
Related Search
Related Contents
manuale d`uso e installazione manuel d`emploi et FRITADORES ELÉTRICOS CFE-550 CFE-270 CFE-190 Viewsonic VT1602-L 15.6" Grey LED TV LS-T10 Systèmes d`enceintes TV Manuel d`utilisateur Sony MDR-IF140K headset USB Protocol Suite User Manual Kawai CL25 Electronic Keyboard User Manual Bau- und Bedienungsanleitung für ‚Clear Tube' Clock IN-8 Copyright © All rights reserved.