Home

Siemens 140 User's Manual

image

Contents

1. Adjusting the fan speed e Press the fan mode button until the desired fan mode is reached e In Automatic mode A the fan speed is automatically selected by the thermostat depending on the setpoint and the actual room temperature When the room temperature reaches the setpoint the fan stops factory setting or runs at low speed P15 e In Manual mode the fan operates independently and always runs at the same speed Low medium high Low Medium High Note If desired you can change the fan mode selector option via P03 Manually only or manually including Protection mode Use P15 to set the fan speed in dead zone Selecting Comfort mode O 4 A Fy e Press the operating mode button until symbol 4 appears indicating that Comfort mode is selected e In Comfort mode the thermostat maintains the setpoint which can be readjusted with the rotary knob Selecting Protection mode r e Press the operating mode button until symbol Or appears indicating that Protection mode is selected e In Protection mode the plant stops operating If the room temperature falls below 8 C heating is switched on however to protect the room against frost The setpoints for Protection mode can be changed by your HVAC installer if desired Changes made by installer Frost protection CHeat protection C Selecting Economy mode CC d In Economy mode the room temperature is maintained at a lower or higher setpoint
2. 9 30 b Turn the rotary knob counterclockwise to extend Economy mode Display 4 0 9 30 Release the operating mode button and the mode is temporarily changed indicated by X After the temporary timer has elapsed the thermostat will resume operation in the operating mode that was active before New operating mode Economy New operating mode Comfort Extended Comfort mode Extended Economy mode If Economy cannot be selected via the operating mode button PO2 2 Protection mode will be used for extended absence instead The temporary timer function is aborted whenever a new setting is made Note Extended Comfort mode is also possible when an external contact such as a keycard switch or central time clock is active To enable this function the time for the extended period must be set via parameter P68 Changing from heating to cooling mode Depending on the type of plant the changeover from heating to cooling or vice versa is made either automatically by a changeover sensor or a remote change over switch or manually by pressing the operating mode button see parameter P0O1 e To select cooling or heating manually PO1 2 press the operating mode button until the desired mode appears e With automatic changeover or continuous heating cooling symbols 2 indicate that the system currently operates in heating or cooling mode e With manual changeover symbol 4 appears indicating that the system c
3. temperature display 0 O Room temperature 1 Setpoint PO7 Additional display information 0 no display i Candi sr PO8 Comfort basic setpoint A 3E 540 C PO9 Minimum setpoint limitation in Bee 5 40 C Comfort mode P10 Maximum setpoint limitation in 35 C 5 40 C Comfort mode P11 Setpoint for heating in Economy 15 C OFF 5 C WcoolEco mode WheatEco P12 Setpoint for cooling in Economy 30 C OFF WheatEco 40 C mode WcoolEco P13 Electric heater in cooling mode ON OFF Disabled ON Enabled P14 Button lock 0 0 Disabled 1 Automatic 2 Manual P15 Fan speed in dead zone 0 0 Disabled Comfort mode 1 Stage 1 H or C 2 Stage 1 Cooling only The control parameters displayed depend on the DIP switch settings made Siemens Switzerland Ltd Subject to change B3181 1en 21 Oct 2011
4. SIEMENS Operating Instructions n RDG100 110 140 160 RDG the electronic room thermostat that allows you to set the ideal room temperature you want The thermostat satisfies your individual needs in all operating modes Comfort Economy and Protection The fan operates either in Automatic mode or at the selected speed when using Manual mode You can either rely on the factory settings or make adjustments that suit your individual needs Main display Operating mode SIEMENS ogg Room ee 4 eae temperature D Sie reas pu SOP RE N aux Electric heater on degrees Celsius Room temperature in i Cooling mode degrees Fahrenheit Button lock active 30 Comfort Alert indicator Economy Protection mode Protection against frost Indicator for selecting mode QA Condensation in the room Temporary timer function active agaaa Additional user information a Operating mode F d button Sn q Fan mode button Automatic AUTO Rotary knob Manual q oI Low medium high Changing the room temperature T e The room temperature setpoint can be adjusted with the rotary knob when E Comfort mode 2O 4is active e Turn the rotary knob clockwise to increase or counterclockwise to decrease the current room temperature setpoint for Comfort mode The setting range is from 5 40 C unless limited by parameters PO9 and P10 for parameter settings see reverse side
5. thus saving energy and money e When selecting Economy make sure that parameter PO2 is set to 2 e Press the operating mode button until symbol 4 appears e You can change the preselected setpoint by adjusting parameters P11 and P12 for parameter settings see reverse side Important The setpoint for Economy can be set to OFF This means that the thermostat is deactivated Risk of frost i e no protective heating or cooling function is provided Energy saving tips without sacrificing comfort e Air out rooms for short periods of time only but properly with the windows wide open e Never allow the room temperature to exceed 21 C through heating and to fall below 25 5 C through cooling Button lock e To lock or unlock the buttons manually press and hold the fan mode button for 3 seconds The buttons are locked or unlocked in this manner if P14 is set to 2 e If P14 is set to 1 the thermostat automatically locks the buttons 10 seconds after the last adjustment Temporary timer for extended presence or absence The Comfort and Economy modes can be temporarily extended by 0 5 to 9 5 hours using the temporary timer 1 2 SIEMENS To set the temporary timer press and hold the operating mode button for maximum 3 seconds While holding the button turn the rotary knob clockwise or counterclockwise as required a Turn the rotary knob clockwise to extend Comfort mode Display lt 4 0
6. urrently operates in heating or cooling mode amp 4 _ au oY SFER Po nT E H E Ta h 1 z R a lv g lv ERI Le _e BEN NX N R M i O me Sy a If you want to change control parameters proceed as follows 1 Press both buttons simultaneously for at least 3 seconds 2 Release them and within 2 seconds press the right button again for 3 seconds The display shows P01 3 Select the required parameter by turning the rotary knob 4 Press button w OK The current value of the selected parameter starts blinking and can be changed by turning the rotary knob 5 Press button w OK to confirm the adjusted value or lf Esc to cancel the change If you wish to adjust additional parameters repeat steps 3 through 5 or press f Esc to leave the parameter setting mode Parameter list No Parameter name PO1 Control sequence Default value 2 pipe 2 stage 1 cooling only Setting range Adj 0 heating only 1 cooling only 2 H C changeover manually 3 H C changeover auto 4 pipe 4 heating and cooling 4 HandC PO2 Mode selection via operating 1 1 Comfort Protection mode mode button 2 Comfort Economy Protection mode PO3 Mode selection via fan mode 0 O Auto Manual button 1 Manual 2 Auto Manual Protection mode P04 Selection of C or F 0 0 1 F PO5 Sensor calibration 0 0K 3 3K PO6 Standard