SharkRack 42U User's Manual
Contents
1. S h ar k R ac k OFFICIAL COPY 1D 00210 000 Enclosure Installation Guide 37U Cabinet 37 DP 42 DP 42U Cabinet 37 DP 42 DP 45U Cabinet 37 DP 42 DP Figure 1 42U X 42 DP Shown ID 00210 000 REV D ECO2773 Page 1 of 46 Proprietary Information of SharkRack Inc 32920 Alvarado Niles Rd Suite 250 Union City CA 94587 510 477 7900 e 510 324 1664 e www sharkrack com SharkRack Enclosure Installation Guide Table of Contents Wale Ol Contes cocine ENEE E 2 E A O o A 3 A SIN TON se Se Baa A ence tN hand cadet E cadena d ebadined E E T 4 Important Safety Notes For Installation oooonnnncnnnncccccccccccncccnnnnnananancnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 4 Chapter TESTO Preparation re ects crake Sas tated barca cores acetate ceca iia 6 o Check Facility Provisions a a Sa aS e A e ds lts lo e de 6 o Cabinet with Full Rear and Front DOOFS ccccccnnccccccccnncccconnnananoncnonnnnnnnnnnnnnnnnnncnnnnnnnnnnnnnns 7 a Cabinet with Split Rear Dosis lia 8 Chapter 2 Receiving and Unpacking cccccccccnncnonococnnonoconananenannnonnnncnnnnnnnnnnnnnnnnnncnnnnnnnnnnnnnnnnnnn 9 a Unpacking Instructions Standard Packaging ccccccccccnnncccnccncnnncccnnnnnnananancnnnnncnnnnnnnns 10 o Unpacking Instructions Integration Packaging ccccccccnnccccccccnnnnccnnnnnanaaancnnnnnncnnnnnnns 12 Chapter 3 Configure Accessories into the Cabinet ooooncnninnccccnnnnnnnncnnconancccnccncnnnnnnnnnnnnnnnos 14 o Co
2. on page 15 5 Use a Phillips head screwdriver to remove the hinge pin brackets and latch bracket s from the cabinet frame Figure 16 42U X 37DP Shown 1D 00210 000 REV D ECO2773 Page 19 of 46 SharkRack Enclosure Installation Guide How to Reverse the Door Swing cont Step Detail 6 Reinstall the hinge pin brackets and latch bracket s on the opposite side of the cabinet 7 Reinstall the door CAUTION Ensure that the door and its hinge a pins are secured into the hinge brackets after the door is reinstalled Figure 17 42U X 37DP Shown 1D 00210 000 REV D ECO2773 Page 20 of 46 SharkRack Enclosure Installation Guide Adjusting the Leveling Feet Step Detail The leveling feet help stabilize the cabinet and keep the cabinet level on uneven floors This should be done before you install products into the cabinet 1 Locate the 4 leveling feet There is one in each corner as shown 2 Loosen the Jam Nut Figure 18 42U X 37DP Shown 3 Lower the leveling feet Rotate the leveling feet clockwise from inside the cabinet using E a straight blade screwdriver or from underneath the cabinet using the supplied 9 16 wrench The levelers should plant firmly to the floor Dua ES y eo A ONS Hg Figure 19 42U X 37DP Shown 1D 00210 000 REV D ECO2773 Page 21 of 46 SharkRack Enclosure Installation Guide Installing the Retractable Ti
3. 19 inch EIA Power Strip CONt ooooonnnccccccccnnnncccnnnncnnnancnnnnnnnnnnnnnns 30 o Installing a Typical 19 inch EIA Power Strip COnt ccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 31 o Cable Manageme nt cccccceeeeeeceececeeeeeeeeeeeeeeaeeaeeeeeeeeeeeaaaaaaaeeeeeeeeeeeesecnaaeaeeeeeeeeteneas 32 o Installing a MultiBay stas erica erste ee nde neta ete dete a arta ceda 33 Chapter 4 Install Computer EQUIP tics sac vada sac eo eee ance i ands sae Uae rei 34 o Cabinet settings for various manufacturers GOVICES ccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 34 Chapter 5 Final ASSOMDIV caricia tico 36 Appendix AGS ica rl cielos 37 Appendix B Basic Cabinet Components ooococcccccccconononananononnnnccnnnnnnnnnnnnnnnnncnnnnnnnnnnnnnnnnnncnnnnnnnes 40 Appendix C Cabinet SpecificatiONS o oooooccccnnccccnonoccconcncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn cnn nnnnnnnnnnnnnnns 42 A a ON 46 1D 00210 000 REV D ECO2773 Page 2 of 46 SharkRack Enclosure Installation Guide Introduction Thank you for buying a SharkRack computer cabinet The SharkRack family of computer cabinets has been designed with great care and made with the highest quality materials to provide you with many years of satisfactory use The SharkRack cabinet provides a top of the line cabinet with features that make installation management and ongoing maintenance fast easy and safe We sincerely hope you enjoy using your SharkRack cabinet and we always
4. AO ta aidan A data ddr 38 Foure Aisen i tee da tel tian lee atdatin beaten wade patel en beara Heda a tein teen lee eda 38 A dante ther lee dat td Ace A Leute deena tena ude iced as 38 FOUE A sation lle dati ii lee heat ws 39 FIQUIO AA add didas 40 Figure Ai o died 43 Foure Aita 44 1D 00210 000 REV D ECO2773 Page 45 of 46 SharkRack Enclosure Installation Guide Warranty LIMITED WARRANTY AND WARRANTY DISCLAIMER Seller warrants that the System will be free from defects in materials and workmanship for a period of one 1 year from date of delivery to customer premises Seller s sole liability and Customer s sole and exclusive remedy for any breach of this warranty is at Seller s option and expense to repair or replace any defective System that is returned to it by Customer Seller will have no obligation under this section to the extent any defect in the System is caused by or is attributable to negligence accident misuse abuse use of the System than in accordance with Sellers documentation or user manual modifications alterations or repairs to the System made by a party other than Seller or actions of third parties or like events outside Seller s reasonable control EXCEPT AS EXPRESSLY SET FORTH IN THIS SECTION TO THE EXTENT PERMITTED BY APPLICABLE LAW SELLER DISCLAIMS ANY AND ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR
5. Grounding Kit for details 3 Release the latches and lift the Side Panel up and off the cabinet frame 4 Remove the Side Panel and set aside To install a Side Panel 1 Approaching the cabinet from the side set the bottom edge of the Side Panel onto the Cabinet Frame 2 The bottom edge of the panel must securely engage with the cabinet frame before pushing the top of the panel forward into place 3 Lock the panel using the key if preferred Detail Figure 26 42U X 37DP Cabinet Shown 1D 00210 000 REV D ECO2773 Page 26 of 46 SharkRack Enclosure Installation Guide Installing a Grounding Kit Step Detail Grounding points are provided on the various cabinet components so that each component can be electrically bonded to the frame Detail A Shows how to route the grounding cables through the frame of the cabinet Connection 1 attaches to either of the door assemblies Connection 2 attaches to the side panel Detail B Shows where connection 2 attaches to the corner of the Side Panel Detail C Shows how to route the grounding cable to the top panel Detail D Shows the door grounding cable being routed through the face of the corner post reverse side of Detail A DETAIL A 4 PLACES DETAIL D Figure 27 Grounding Points 42U X 37DP Cabinet Shown ID 00210 000 REV D ECO2773 Page 27 of 46 SharkRack Enclosure Installation Guide Using the SharkTRA
6. SharkRack offers an optional line of electronic door handles which use HID or keypad entry These locks can be networked together for remote management and access tracking To install follow the steps CAM 1 Open the door 2 Rotate the handle to align the cam pointing down 3 Use a screwdriver to push the snaps inward Lift the handle off the door Obb 4 Install new door handle Note The installation of some door handles may require gt additional steps Consult the installation guide with for your specific door handle option Figure 14 Snap In Handle and Lock 1D 00210 000 REV D ECO2773 Page 17 of 46 SharkRack Enclosure Installation Guide How to Reverse the Door Swing Step Detail Reverse the door handle 4 1 Open the door A 2 Rotate the handle to align the cam pointing 4 down Mae My A 3 Use a screwdriver to push the snaps inward Lift 7 X Y the handle off the door CAM g 4 Remove the cam screw securing the cam and i A Ly rotate the cam 180 Re secure with the cam Sx Z screw in 5 Rotate the door handle assembly 180 and Sy i reinstall it e hg Y Bi E Fi Abe Figure 15 Snap In Handle and Lock 1D 00210 000 REV D ECO2773 Page 18 of 46 SharkRack Enclosure Installation Guide Step Detail Reverse the door hinge brackets 4 Remove the door See Installing and Removing Doors
7. Table 1 Cabinet Dimensions DIM 37 CABINET 42 CABINET 45 CABINET A 86 91 82 B 41 46 49 6 37 40 45 eine Feet 35 40 43 Floor E brackets 38 or 40 43 or 45 46 or 48 REV D ECO2773 Page 7 of 46 SharkRack Enclosure Installation Guide Rack Cabinet Footprint and Mounting Locations for Cabinet with Split Rear Door 1D 00210 000 24 Rear Doors om HD ao Front Door Figure 4 42U X 37DP TOP VIEW and 42U X 42DP BOTTOM VIEW Shown Table 2 Cabinet Dimensions DIM 37 CABINET 42 CABINET 45 CABINET A 74 79 82 B 41 46 49 C 37 42 45 RR Feet 35 40 43 eae ati ae ae 38 or 40 43 or 45 46 or 48 REV D ECO2773 Page 8 of 46 SharkRack Enclosure Installation Guide Chapter 2 Receiving and Unpacking Check package and receiving area e Verify contents and condition e Move the packaged cabinet on its pallet as close to its final destination as possible e Be sure there is enough room to unload the cabinet from its packaging In front of the pallet it requires at least 7 feet for standard packaging with or without pallet and 13 feet for integration crate packaging to unload the cabinet e Many SharkRack cabinets come on casters which allow the cabinet to
8. a power device to ensure that it does not exceed the maximum rating of the power strip or any UPS to which it may be connected Each installed server or other device might have more than one power cord Be sure to disconnect all power cords in the cabinet before servicing any device in the cabinet CAUTION Removing components from the top portion of the rack improves cabinet stability during relocation Follow these general guidelines whenever you relocate a populated cabinet within a room or building Reduce the weight of the rack by removing equipment starting at the top of the rack When possible restore the cabinet to the configuration as you received it If this is not possible or the configuration is unknown remove all devices in the 11U position and above before moving the cabinet Inspect the route that you plan to take and eliminate any potential hazards Verify that the route that you choose to move the rack cabinet can support the weight of the loaded rack cabinet which may exceed 2500 Ibs Verify that all doorways can accommodate the cabinet Ensure that all devices drawers doors and cables are secure Ensure that all leveling feet are raised to their highest position Ensure that the floor mounting brackets are removed see Figure 6 Once the cabinet is in its new location repopulate the cabinet from the lowest position to the highest position If long distance relocation is required pack the cabinet in the orig
9. are level and square to each other 3 Secure the 4 MultiBay plates to the cabinets using 4 M6 screws in each plate Figure 38 MultiBay Kit 1D 00210 000 REV D ECO2773 Page 33 of 46 SharkRack Enclosure Installation Guide Chapter 4 Install Computer Equipment To install computer equipment into the cabinet e Plan component locations in the cabinet e Install computer equipment e Route and secure all loose cables accordingly Note Refer to important safety note for installation on page 4 prior to installing equipment Cabinet settings for various manufacturers devices Note Always review equipment manufacturer s manual for specific mounting specifications Compaq e Most Compaq rack mountable products require 3 8 square holed L style mounting rails e Distance between the front and rear mounting rails needs to be 29 12 inches Many rack mount kits from Compaq use fixed depth side rails and require the cabinet mounting rails to be exactly 29 12 inches apart e Typically products use 6mm cage nuts and screws Dell e Most Dell rack mountable products require 3 8 square holed L style mounting rails e Typically products use 10 32 cage nuts and screws e If a front door is required use a fully vented front door Hp e Most HP rack mountable products use a 3 8 square holed L style mounting rails e Typically products use 10 32 cage n
10. details 5 With one person on each side of the enclosure carefully roll it out of the wooden crate 6 Unwrap packing material from around the cabinet Optional Store all packing materials in a safe place for future use Figure 11 Shipping Crate with 42U X 37DP Cabinet Shown 1D 00210 000 REV D ECO2773 Page 13 of 46 SharkRack Enclosure Installation Guide Chapter 3 Configure Accessories into the Cabinet Configure Optional Accessories The SharkRack cabinet can be configured using multiple optional accessories The configuration depends on your specific application and may vary from cabinet to cabinet The following list of processes is organized to help guide you through the typical steps of configuring optional accessories Since each configuration is different some processes may be excluded Also some processes will refer back to previous processes Installing and Removing Doors Changing Door Handles How to Reverse the Door Swing Adjusting the Leveling Feet Installing the Retractable Tip Guard Installing the Floor Mounting Brackets Adjusting or Replacing the Mounting Rails Installing Side Mounting Brackets How to Remove or Install a Top Panel How to Remove or Install Side Panels Installing a Grounding Kit Using the SharkTRAC and SharkSNAP Installing a 19 inch EIA Power Strip Cable Management Installing a MultiBay Kit Tools Required for Cabinet setup ID 00210 000 2 Phillips Screwdrive
11. gt Remove the hardware from the brackets as required o gt Rotate the mounting brackets as required Reinstall the hardware Figure 31 1c Secure the strip using 6 10 32 x 1 2 inch panhead screws 1d Connect necessary cables Figure 32 ID 00210 000 REV D ECO2773 Page 29 of 46 SharkRack Enclosure Installation Guide Installing a Typical 19 inch ElA Power Strip cont Detail Step 2 Secure to the SharkTRAC using SharkSNAP Brackets Note There must be two SharkSNAP brackets installed which allows a power strip to clip in between them 2a Install a pair of SharkKSNAP brackets into the SharkTRAC See Using the SharkTRAC and SharkSNAP on page 28 for further details 2b Approach the SharkSNAP brackets with the power strip Align the pins of the SharkSNAP bracket with the screw holes on the strip mounting brackets and push the strip straight onto the bracket There is a spring that La holds the strip into place 2c Connect necessary cables Figure 33 1D 00210 000 REV D ECO2773 Page 30 of 46 SharkRack Enclosure Installation Guide Installing a Typical 19 inch ElA Power Strip cont Step 3 Secure to the SharkTRAC using screws 3a Install 10 32 cage nuts The SharkTRAC requires the use of cage nuts install them into the appropriate holes using the method shown Detail Figure 34 Cage Nut instillation 3b As required Adju
12. nut you must specify the thread size as well as the thickness of the mounting rail they will be attaching to Figure 40 Cage Nut Clip Nut A fastener typically used on round hole universal type racks similar to a Cage Nut They come in different shapes and sizes You must specify the thread type as well as the thickness of the mounting rail they will be attaching to GEN VA Figure 41 Clip Nut SharkSNAP SharkSNAP is a family of tool less clip in devices that attach to the SharkTRAC SharkSNAP devices reduce time and hassle when installing things such as power strips patch panels routers and environmental monitoring products into a cabinet 1H Figure 42 SharkSNAP 1D 00210 000 REV D ECO2773 Page 38 of 46 SharkRack Enclosure Installation Guide Appendix A Glossary cont SharkTRAC M The SharkTRAC is a platform consisting of a series of holes which allows attachment of various devices such as the family of SharkKSNAP tool less clip in devices Figure 43 SharkTRACTM 1D 00210 000 REV D ECO2773 Page 39 of 46 SharkRack Enclosure Installation Guide Appendix B Basic Cabinet Components Note Before you begin configuring your SharkRack cabinet it is best to verify that you have received all necessary items to begin your installation Also verify that your equipment has arrived free of damage Rack configurations may vary Figure 44 42U X 42DP Cabinet Exploded View 1D 0021
13. 0 000 REV D ECO2773 Page 40 of 46 SharkRack Enclosure Installation Guide Parts List REF Description Quantity REF gt Cabinet Frame 7 Front Door Kit Grommet Bumper Bracket Latch Front Door Front Hinge Bracket Top Left Bottom Right Front Hinge Bracket Top Right Bottom Left Front Door Perforated Snap In swing Handle 10 32X 375 Flat Head Screw oo po Full Rear Door Kit Bracket Latch Full Rear Door Snap In swing Handle Grommet Bumper Rear Hinge Bracket Top Left Bottom Right Rear Hinge Bracket Top Right Bottom Left 10 32X 375 Flat Head Screw Full Rear Door Perforated Split Rear Door Kit Rod Latch 10 32 Flat Head Screw Sl o 10 Hex Nut w Tooth Washer Rear Hinge Bracket Top Left Bottom Right Rear Hinge Bracket Top Right Bottom Left Grommet Bumper Right Hand Split Door Left Hand Split Door 5 Filler Panel Side Panel Casters Leveling Feet Floor Mounting Bracket Non Perforated Top Panel I ej O mim Mounting Rails Set of 4 N A BY PO DN NY PO Po N ID 00210 000 Table 1 Parts List REV D ECO2773 Page 41 of 46 SharkRack Enclosure Installation Guide Appendix C Cabinet Specifications Note The information listed on the chart in Table 2 is taken from SharkRack s latest gen
14. 1D 00210 000 REV D ECO2773 Page 24 of 46 SharkRack Enclosure Installation Guide How to Remove or Install a Top Panel Step Detail The Top Panel can be removed To remove a Top Panel 1 Unlock the Top Panel using the key 2 With the key turned in the unlocked position lift up until you can grab the top panel with your free hand Note If using a grounding kit remove the cable prior to lifting the panel from the Cabinet Frame See Installing a Grounding Kit for details 3 Remove the Top Panel and set aside To install a Top Panel 1 Set the Top Panel on the top of the Cabinet Frame When installed properly it should sit flush with the rest of the cabinet 2 Lock the Top Panel using the key if preferred Figure 25 42U X 37DP Cabinet Shown 1D 00210 000 REV D ECO2773 Page 25 of 46 SharkRack Enclosure Installation Guide How to Remove or Install Side Panels Step The Side Panels can be removed to provide further access to equipment mounted inside the cabinet This is a great way to get added access for cable management or installing powerstrips To remove a Side Panel 1 Unlock the Side Panel using the key if necessary 2 Slide both Side Panel latches inward towards each other at the same time and tilt the panel outward Note If using a grounding kit remove the cable prior to lifting the panel from the Cabinet Frame See Installing a
15. C and SharkSNAP Step The SharkTRAC is a patent pending platform consisting of a series of holes which allows attachment of various devices We have also developed a family of SharkSNAP tool less clip in devices that attach directly to the SharkTRAC SharkSNAP devices reduce time and hassle when installing things such as power strips patch panels routers and environmental monitoring products Detail SharkSNAP SharkTRAC ee Figure 28 1 To install a SharkSNAP align the small metal fingers over the holes of the SharkTRAC Drop the fingers through the holes and slide the SharkSNAP into the track until the retention pin snaps into place 2 To remove a SharkSNAP pull up on the retention pin and slide the SharkKSNAP back and away from the SharkTRACTM Figure 29 1D 00210 000 REV D ECO2773 Page 28 of 46 SharkRack Enclosure Installation Guide Installing a Typical 19 inch ElA Power Strip Step Detail 1 Secure to the Cabinet Mounting Rails 1a As required Install 10 32 cage nuts Some mounting j 7 7 gt rails require the use of cage nuts install them into the f i appropriate holes as shown Or Or Install 10 32 clip nuts as shown Some mounting rails require the use of clip nuts install them into the appropriate holes as shown Figure 30 1b As required Adjust the mounting brackets orientation iy e
16. Cabinet Dimensions 1D 00210 000 REV D ECO2773 Page 43 of 46 SharkRack Enclosure Installation Guide Mounting Rail Dimensions Front View EA n Bs E H G E Figure 46 Mounting Rails 1D 00210 000 REV D ECO2773 Page 44 of 46 SharkRack Enclosure Installation Guide FIQUIO Misa ta dd tdi de add delata 1 A NN 7 A O O NTE 8 IQUITOS a r ENEE ENE ey cell ea Ie lubes ie ETN T A AE ETENA dupes tdubeeeyceubeety teint a lala 10 Figure Diarrea ica diia eiii 10 IQUITOS a IO A A E 11 FIQUING A A E et sway Sates cae dante eccee ducted Saute peaceatat sub auate I A agate eeagedi T 11 A a 12 FIQUING a 12 A Wii act ceeds tech wa ctsccacee tic tes neces E tat alte tad A E N I T TT 13 EQU Ti I INA E N E IN 15 EERE A A TA A E A N A E T 16 EER A 17 DAE E E A A E NAA N E E N N 18 FIQUES rca A E E A E A A E A E 19 FUG 17 T A A T EA A ng EAI T A OE T E 20 EA EEE thes E E E A E E E E A E A 21 Fiare o N 21 Fore aO aa a R E N E A ONON 22 HU ad 22 IU Llaca oa O late 23 AU Ta 23 IU A a laca nano La 24 IU A Ta 25 IU 2G a aca nai O la 26 EU A erence eerrecrer rr E N 27 FU 2G se ce cas sccht als 2 hea ansehen aca naaa rae 28 ENE EE E ao ai ao T 29 A A 29 FOUTE li a Ati 29 FOUE li ded Le ees ee eee eee eed 30 FEU 34 ithe diate a Mead ee eet A noe ee ee ee 31 PIQUIO 35 ict hi did eid A Le eet ee eee eee eed 31 FU O iii A Me aed eet A nea ee eed 31 FOUTE I 7th neti eta A ee eed eee ee ed 32 FIGURA 33 EU Oi a 37 FOUC
17. PURPOSE QUALITY OR NONINFRINGEMENT AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE LIMITATIONS OF LIABILITY IN NO EVENT WILL SELLER BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOST PROFITS OR REVENUE LOSS OF USE LOST BUSINESS OPPORTUNITIES OR LOSS OF GOODWILL OR FOR THE COSTS OF PROCURING SUBSTITUTE PRODUCTS ARISING OUT OF OR IN CONNECTION WITH THESE TERMS OF SALE OR THE USE OF THE SYSTEM WHETHER SUCH LIABILITY ARISES FROM ANY CLAIM BASED UPON CONTRACT WARRANTY TORT INCLUDING NEGLIGENCE PRODUCT LIABILITY OR OTHERWISE WHETHER OR NOT SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSS OR DAMAGE IN NO EVENT WILL SELLER S TOTAL CUMULATIVE LIABILITY FROM ALL CAUSES OF ACTION AND ALL THEORIES OF LIABILITY EXCEED THE TOTAL AMOUNTS ACTUALLY PAID TO SELLER BY CUSTOMER UNDER THE ORDER THAT GIVES RISE TO ANY LIABILITY HEREUNDER During the warranty period purchaser must promptly call SharkRack 877 427 5722 to log any such defects in materials and workmanship ID 00210 000 REV D ECO2773 Page 46 of 46
18. able to bolt down the cabinet Refer to Site Preparation Information Figure 22 Floor Mounting Bracket 2 Secure the Floor Mounting Brackets to the front and rear of the cabinet base using supplied hardware 3 Have a qualified professional fasten the brackets to your data center floor Figure 23 Floor Mounting Bracket on 42U X 37DP cabinet ID 00210 000 REV D ECO2773 Page 23 of 46 SharkRack Enclosure Installation Guide Adjusting or Replacing the Mounting Rails Step Adjusting the mounting rails The mounting rails are factory set at 29 12 inches apart However both the front and rear mounting rails are adjustable to any depth within the cabinet 1 Loosen the screws securing each mounting rail using a Phillips screwdriver 2 Adjust the mounting rail to the desired location Make sure each mounting rail is adjusted parallel and square inside the cabinet 3 Tighten the screws 4 Repeat steps for any other rail to be adjusted Replacing the mounting rails To replace any of the mounting rails you must 1 Loosen the screws securing the mounting rail CAUTION Remove bottom screws first to help eliminate the possibility of the rail falling on your head 2 Remove the rail and replace with another style rail available from SharkRack 3 Secure the mounting rail with the screws that were previously removed Detail Section view of 42 w 7DP Cabinet
19. ays install a stabilizing anti tip device such as Floor Mounting Brackets or a Retractable Tip Guard Always install the UPS uninterruptible power supply in the bottom of the rack Always install the heaviest equipment in the bottom of the rack Always install servers and power devices in the rack from the bottom to the top Do not extend more than one sliding device at a time The center of gravity for an extended unit cannot exceed 16 inches from the face of the cabinet If an extended device exceeds this distance the configured cabinet might be unstable The maximum allowable weight for devices on slides is dependant upon the specific slide Do not install sliding devices exceeding maximum allowed weight 1D 00210 000 REV D ECO2773 Page 4 of 46 SharkRack Enclosure Installation Guide WARNING CONT Plug cabinet power cords into electrical outlets that are located near the cabinet and are easily accessible Connect all devices installed in a rack to power devices installed in the same cabinet Do not plug into a power device installed in a different cabinet Check the equipment power rating before plugging into a cabinet power device Check that both the voltage range and current draw are within the limitations of the power device The voltages of the power device receptacles are typically equal to the voltages of the UPS or AC source To avoid overloading check the total input current rating of the equipment being connected to
20. be rolled to its destination after unpacking Note Ensure clear passage from the receiving site to the uncrating site Do not lift an unpackaged cabinet with a forklift Do not move the packaged cabinet without adequate assistance Be sure leveling feet are raised before rolling to prevent tipping or damage to the feet ID 00210 000 REV D ECO2773 Page 9 of 46 SharkRack Enclosure Installation Guide Unpacking Instructions Standard Packaging Step Detail Note Unpacking of a cabinet requires at least two people There must be at least 7 feet of clear area in front of the loaded pallet to unload the cabinet 1 Unwrap packaging material from around the cabinet Figure 5 42U X 42in DP Shown o E ES 2 Remove the 4 bolts securing the front Floor Mounting Bracket to the pallet and cabinet 3 Repeat Step 2 for the rear Floor Mounting Bracket Figure 6 42U X 42in DP Shown Removal of Floor Mounting Bracket 1D 00210 000 REV D ECO2773 Page 10 of 46 SharkRack Enclosure Installation Guide Step Detail CAUTION Be sure the leveling feet are fully raised to prevent accidental tipping Figure 7 View of Caster and Leveling Foot 4 With one person on each side of the enclosure carefully roll it toward the rear of the pallet until the rear casters clear the back edge of the pallet Continue to slide the enclosure rearward until the rear casters ma
21. eration of racks Previous generations vary from that listed bellow Note The Reference column of Table 2 references the Figures and the following pages All Measurements are listed in Inches unless otherwise specified Cabinet Depth Reference 37 42 45 19 985 19 985 18 42 18 42 17 925 17 925 1046 12 Gage 1046 12 Gage 28 91 28 91 19 78 19 78 Distance Between Frame Members Mounting Rail Mounting Holes Center to Center i Mounting Flange Inside Width Mounting Rail Thickness in N co oO Front Mounting Flange to Rear Mounting Flange Interior Clearance Front Mounting Rail to Inside of Front Door Rear Mounting Rail to Inside of Rear Door in Cabinet Width fin Inside Front Door to Inside Rear Door in Distance from frame to Fornt Door Handle i Distance from frame ro Rear Door Handle in 9 13 23 09 40 23 In N oo wo q 5 Cabinet Depth With Doors Front Door Perforation Open Area 64 6 64 t E O CA a OREA IE 40 09 wo Cabinet Depth Frame Only Rear Door Perforation Open Area 6s 64 64 Service Clearance Front inp _ 235 5 5 Service Clearance Rear Split Rear 24 12 24 12 24 12 Table 2 Cabinet Specifications All dimensions are nominal unless indicated otherwise 1D 00210 000 REV D ECO2773 Page 42 of 46 SharkRack Enclosure Installation Guide Cabinet Dimensions Top View us Figure 45
22. inal packaging material or equivalent Also use the floor mounting brackets to bolt the cabinet to the pallet ID 00210 000 REV D ECO2773 Page 5 of 46 SharkRack Enclosure Installation Guide Chapter 1 Site Preparation Check Facility Provisions Ensure that the following conditions are met 1D 00210 000 Floor is level and of sufficient strength to support the rack and your equipment At maximum gross weight the floor must be able to support 1000 lb in A qualified professional should complete site electrical power supply set up Ensure the types of outlets are consistent with the type of plugs on the power devices to be used Check with a qualified HVAC technician to make sure the environment will support the heat load of the products being installed in the cabinet Select a location for the cabinet that will allow adequate space for the door to open freely and slide mounted equipment to be extended Check that the site can accommodate the cabinet footprint and mounting locations according to the illustrations in Figure 3 and Figure 4 REV D ECO2773 Page 6 of 46 SharkRack Enclosure Installation Guide Rack Cabinet Footprint and Mounting Locations for Cabinet with Full Rear and Front Doors 1D 00210 000 ae H je Poci 120 T Rear Door 23 82 Figure 3 42U X 37DP TOP VIEW and 42U X 42DP BOTTOM VIEW Shown
23. ke contact with the floor 5 While one person carefully tips the enclosure slightly away from the pallet have the other person pull the pallet away from the enclosure Optional Store all packing materials in a safe place for future use Figure 8 42U X 42DP Shown ID 00210 000 REV D ECO2773 Page 11 of 46 SharkRack Enclosure Installation Guide Unpacking Instructions Integration Packaging Step WARNING A fully loaded cabinet is very heavy Take proper precautions when moving the cabinet Note Unpacking of a cabinet requires at least two people There must be at least 13 feet of clear area in front of the loaded crate to unload the cabinet 1 Open the Crate Loosen the 6 clips securing the front of the crate The front of the crate is used as a ramp to unload the cabinet Detail Figure 9 Shipping Crate Shown for 42U X 37DP Cabinet 2 Position the loading ramp onto the front of the crate 3 Remove the 2 wing nuts securing the piece of wood at the base of the cabinet 4 Remove the 4 bolts securing the front Floor Mounting Bracket to the crate and cabinet Figure 10 Shipping Crate with 42U X 37DP Cabinet Shown 1D 00210 000 REV D ECO2773 Page 12 of 46 SharkRack Enclosure Installation Guide Unpacking Instructions Integration Packaging cont Step Detail CAUTION Be sure the leveling feet are fully raised to prevent accidental tipping See Figure 7 for
24. nfigure Optional ACCCSSOreS initial iii tii 14 o Installing and Removing DOOFS ooooooccccccccccnccccononccccncncnnnnnnnnnannncnnnnnnnnnnnnnnnnnnnnncnnnnnnnnnnnns 15 o Installing and Removing Doors CONt ooooonnnnnccccncnnncnccnnanonccnncncnnnnnnnnnnnnnnncncnnnnnnnnnnnnns 16 El POOF PIAMQNSS net annee a acl wes duaaiine caved A E A A Cowes mene ueacusimeceencaviayed 17 o How to Reverse the Door Wii nac aaa 18 o How to Reverse the Door Swing CONt ocoocnnnnnccccccnnnccccnnnconoocnncnnnnncnnnnnnnnnnncnnnnnnnnnnnnnns 20 o Adjusting the Leveling Feet ooooonnnncccnnnnnnnncnnnnnncccccncccnnnnnnnnnnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 21 o Installing the Retractable Tip Guard cccccccccnnnccccccccnnncccnnnnnennnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnes 22 o Installing the Floor Mounting BracketS oooonncccccnnnncncccncononcccconononnnnnnnnnnnnnnnnnnnnnnnnnnnnns 23 o Adjusting or Replacing the Mounting Rails oooooccccccccccccncccocccoccninononanananannncnnnnncnanannns 24 o How to Remove or Install a Top Panel ooooccnnncnncccccnncccccnananananncnnncnnnnnnnnnnnnnncnnnnncnnnnnnnns 25 o How to Remove or Install Side Panels ooonmnnccccnnnnnccccccnononcccccccccnnnnnnnnnnancnnnnnnnnnnnnnnnns 26 o Installing a Grounding Md ita 27 o Using the SharkTRACTM and SharkSNAP aiii ic era nieceeeiesae 28 o Installing a Typical 19 inch EIA Power Strip CONt ooooconincccccccccnnncconnncnanaoccnnnnnnonanannns 29 o Installing a Typical
25. ove or Install a Top Panel How to Remove or Install Side Panels Installing a Grounding Kit Using the SharkTRAC and SharkSNAP TM Installing a 19 inch ElA Power Strip Cable Management Installing a MultiBay Kit Figure 2 Common Cabinet Installation Diagram Page 3 of 46 SharkRack Enclosure Installation Guide Symbols in Text A WARNING Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life damage to equipment or loss of information ES CAUTION Text set off in this manner indicates that failure to follow directions could result in Note Text set off in this manner presents commentary sidelights or interesting points of information Important Safety Notes For Installation Note The information contained in this document is subject to change without notice SharkRack makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose SharkRack shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material SharkRack assumes no responsibility for the use or reliability of the software or hardware installed into a SharkRack cabinet Pictures in this manual represent a typical configuration Your actual configuration may vary WARNING Alw
26. p Guard Step The Retractable Tip Guard should be used when the cabinet is not secured to the floor and equipment is being slid in and out of the cabinet This feature is used to prevent the cabinet from tipping over 1 Insert the legs of the tip guard into the base of the cabinet Detent the spring latches towards the rear of each leg Detail Figure 20 42U X 37DP Shown 2 Check the operation of the Retractable Tip Guard It should freely cycle through its full range of motion Note Some adjustment of the center section may be required for smooth operation To adjust loosen the 4 screws at the front of the Tip Guard Reposition the pieces as required Tighten the screws Note When in use remember to fully lower both leveling feet on the retractable stabilizer kit until they are firmly planted on the floor Figure 21 42U X 37DP Shown 1D 00210 000 REV D ECO2773 Page 22 of 46 SharkRack Enclosure Installation Guide Installing the Floor Mounting Brackets Step Detail The Floor Mounting Brackets should be used when sliding equipment in and out of the cabinet and no other stabilizing provisions are in place This safety feature is used to prevent the cabinet from tipping over or to keep it ina fixed location Consult a contractor or trained professional on the best method of fastening your cabinet to the floor 1 Prepare the location Check the location to make sure the area is suit
27. que values are o 10 32 30 inch lbs o M5 24 inch lbs o M6 40 inch lbs Re install the doors See Installing and Removing Doors for details Power up devices REV D ECO2773 Page 36 of 46 SharkRack Enclosure Installation Guide Appendix A Glossary ElA For more than 72 years the Electronic Industries Alliance has been the national trade organization representing U S electronics manufacturers Committed to the competitiveness of the American producer ElA represents the entire spectrum of companies involved in the design and manufacture of electronic components parts systems and equipment for communications industrial government and consumer uses U or RU A Rack Unit or sometimes referred to as U is the measure of space in a rack cabinet enclosure equal to 1 75 inches as defined by the ElA 310 standard Each Rack Unit in an EIA rack cabinet enclosure will have three holes The first hole is spaced at 25 inches from the bottom of the U to the center followed by 2 holes spaced at 625 center to center and then 25 inches to the top of the RU N Figure 39 U Spacing Zero U Zero U is any rack unit that is not a part of the main stacked rack unit in a cabinet 1D 00210 000 REV D ECO2773 Page 37 of 46 SharkRack Enclosure Installation Guide Appendix A Glossary cont Cage Nut A fastener typically used in square hole universal type racks similar to a Clip Nut When selecting the correct cage
28. r 1 2 9 16 Open End Wrench Included with leveling foot kit 9 16 Hex Socket and Ratchet with 3 Extension Bar Optional Straight Blade Screwdriver Optional for adjusting the leveling feet REV D ECO2773 Page 14 of 46 SharkRack Enclosure Installation Guide Installing and Removing Doors Step Detail To remove doors Open the door N Pull down on the spring loaded hinge pin attached to the top of the door 3 Move top of door away from enclosure and lift the bottom of door up from the cabinet and set aside O Figure 12 42U X 37DP Shown ID 00210 000 REV D ECO2773 Page 15 of 46 SharkRack Enclosure Installation Guide Installing and Removing Doors cont Step Detail To install doors 1 Align the lower door hinge pin with the hole in the bottom hinge bracket and slide the hinge pin into the hole 2 Pull down the upper hinge pin 3 Align the upper hinge pin with the hole in the upper hinge bracket and release the hinge pin into the hole 4 Make sure the door opens and closes properly CAUTION Ensure that hinge pins are secured into the hinge brackets If not properly installed the door may unexpectedly fall Figure 13 42U X 37DP Shown ID 00210 000 REV D ECO2773 Page 16 of 46 SharkRack Enclosure Installation Guide Door Handles Step Detail Remove door handle To enhance your cabinet
29. st the mounting brackets orientation Remove the hardware from the brackets as required Rotate the mounting brackets as required Reinstall the hardware Figure 35 Mounting Bracket 3c Secure the strip using 6 10 32 x 1 2 inch panhead screws 3d Connect necessary cables AS LPS Figure 36 PDU installation 1D 00210 000 REV D ECO2773 Page 31 of 46 SharkRack Enclosure Installation Guide Cable Management Step Detail The SharkRack cabinet has been designed with integrated cable management There are numerous provisions for running cables in the corner posts of the frame as well as out the top bottom in both the front and back of the cabinet There are also many places that cables can be tied down to the frame by using nylon ties or hook and loop strips or ties Figure 37 Cable Management 1D 00210 000 REV D ECO2773 Page 32 of 46 SharkRack Enclosure Installation Guide Installing a MultiBay Kit Step Detail MultiBay kits are used to group two or more SharkRack cabinets together MultiBay kits can be installed prior to installing computer equipment into the rack cabinet or after equipment is already loaded Optional Remove the two side panels facing each other from the two cabinets being bayed together See How to Remove or Install Side Panels on page 26 1 Move the two cabinets together 2 As necessary adjust the leveling feet until the cabinets
30. uts and screws but some use M5 fasteners e Ifa front door is required use a fully vented front door e If a front door is required you may need to set all mounting rails back ID 00210 000 REV D ECO2773 Page 34 of 46 SharkRack Enclosure Installation Guide Cabinet settings for various manufacturers devices cont IBM e Most IBM rack mountable products use a 3 8 square holed L style mounting rails e Typically products use 10 32 cage nuts and screws e If a front door is required use a fully vented front door e If a front door is required you may need to set all mounting rails back e Sun has not published a corporate wide set of racking requirements for 3 party cabinets e Check with a SharkRack Representative or www sharkrack com for recommended racking hardware e Most equipment works with the use of SharkRack s 3 8 square holed L style mounting rails e Many of Sun rack mount kits use 10 32 cage nuts and screws but some of their newer equipment uses M6 hardware ID 00210 000 REV D ECO2773 Page 35 of 46 SharkRack Enclosure Installation Guide Chapter 5 Final Assembly Check for Functionality 1D 00210 000 Have a qualified electrician verify the power sources for your specified power requirements Check that there is no obstruction to any device that needs to be accessed for maintenance Check that there is easy access to the power strips Check that all fasteners are tight Typical tor
31. welcome your feedback If you have technical questions about any aspect of installing or using your computer cabinet please call us at 87 SHARKRACK 877 427 5722 SharkRack intends this manual to guide you through a smooth cabinet installation SharkRack assumes that you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with high energy levels SharkRack also assumes you are qualified to move heavy pieces of equipment All the instructions here are presented in great detail This document contains general installation instructions for the various SharkRack cabinet configurations and many of the common optional devices that can be installed into a SharkRack cabinet Always consult the documentation that comes with your computer product or accessory for detailed installation instructions The following diagram shows an overview of a common cabinet installation Chapter 1 Site Preparation Installing and Removing Doors Changing Door Handles Chapter 2 Receiving And Unpacking Chapter 3 Configure Accessories Into the Cabinet Chapter 4 Install Computer Equipment Chapter 5 Final Assembly 1D 00210 000 0D OOO OOOO OO O0 O0 O0 O O O REV D ECO2773 How to Reverse the Door Swing Adjusting the Leveling Feet Installing the Retractable Tip Guard Installing the Floor Mounting Brackets Adjusting or Replacing the Mounting Rails Installing Side Mounting Brackets How to Rem