Home

SECO-LARM USA Enforcer SK-910R4Q User's Manual

image

Contents

1. Installation Manual ENFORCER SK 910R3Q 3 Channels 315MHz SK 910R3 4Q 3 Channels 433 92MHz SK 910R4Q 4 Channels 315MHz SK 910R4 4Q 4 Channels 433 92MHz D SK 910R4A pictured Three and Four Channel RF Receivers e Flexible operating voltage 11 24 VAC VDC Reia e Up to 500ft 152m range Modes e Independently programmable channels Note Products with model numbers that end with Q or that have a round green Q sticker are RoHS compliant Also Available from SECO LARM SK 910RBQ o oo cccccccccccceeccccceesecseneeeseneeessneeesenes One channel receiver 315MHz SK 910RLQ ooo ee ceeeseeeeeeeees Low voltage one channel receiver 315MHz SK 910RVQ 00 ccccccccceeseecsececsseessesseseseeaeeaes Low voltage one channel receiver transistor ground output 315MHZ SK 910R 4Q o oo ccccccccccccccceccceseneeecenseeseeeeesenenes One channel receiver 433 92MHz SK 910RL 4Q oon ees Low voltage one channel receiver 433 92MHz SK 910RV 4 resis catnsceedscrsnusaotasasrerunasortasarentnecs Low voltage one channel receiver transistor ground output 433 92MHz SK 910RB2Q o oo ccccccccceeccccceececeneeesenseeeesereeeenes Two channel receiver 315MHz SK 910RB2 4Q ooo eeen Two channel receiver 433 92MHz This manual covers only the three and four channel receivers For information on all other receivers please contact SECO LARM Introduction The SK 910R3Q and SK 910R4Q are wireless receivers
2. associated with that channel have been deleted Display Channel Memory To see how many codes have been learned in a channel press that channel s transmitter programming button once The number of codes stored in the channel s memory is equal to the number of LED flashes Programming Each Channel Relay Output Mode Each receiver channel can be programmed for one of five different modes and each individual channel may operate at a different output mode depending on the user s application The five modes are 1 Timed Output Press the transmitter button once The timed output relay will activate from 1 60 seconds depending on the set output time See page 3 for information on programming the output time DEFAULT 1 second timed output 2 Toggle Output Works much like a toggle switch to turn a device ON amp OFF alternately Press the transmitter button once and the relay turns ON Press the transmitter button again and the relay turns OFF 3 Latch Output Press the transmitter button once and the relay turns ON and stays ON The relay will remain ON until the appropriate channel s transmitter programming button is pressed once to reset regardless of whether a compatible transmitter button is pressed again or not Validity Output The channel will turn the relay ON for as long as the transmitter button is pressed NOTE Due to possible interference or drops in transmitter battery power while the transmitter butto
3. s LED will start to flash quickly to indicate that it is in the learning mode While the LED is flashing press the button of the transmitter to be learned once The LED will flash once to indicate a successful learning of that button s code After the button has been learned the receiver will automatically exit the learning mode Repeat step 1 to re enter the learning mode NOTE e The transmitter programming buttons can be found at the rear of the receiver s case The button number corresponds with the channel number For example button 1 is the programming button for channel 1 The channel s LED will flash for a maximum of 15 seconds If no transmitter button is pressed during this time the receiver will exit the code learning mode and the LED will turn off If the code being learned has already been learned the LED for the channel which learned the code will turn steady ON and then start flashing again The code will not be learned a second time Each channel can learn the codes of a maximum of 15 transmitter buttons If you attempt to learn a sixteenth transmitter code the earliest code will be deleted N Clear Channel Memory To clear all codes in the channel s memory press the transmitter programming button for that channel for 3 seconds or more until the LED flashes Release and then press that button again for 3 seconds or more until the LED stops flashing The LED will then flash twice to indicate that all codes
4. lopment and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2012 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM SECO LARM U S A Inc 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com aff PITSW1 Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com MiSK 910R3Q_SK 910R4Q_1204 docx 4 SECO LARM U S A Inc
5. ly learned transmitter buttons were deleted or the relay is in toggle output mode Three flashes Latch output Four flashes Validity output In the normal operation mode pressing the channel mode button once will display the number of 0 15 flashes codes learned Extended Range Antenna Optional Extends RF receiver range up to 1 000ft 304m open air with SK 91ERSD existing remotes Comes with a 9ft cable that easily plugs into the 3 pin antenna port located on the RF receiver NOTE e lf an extended range antenna is used the LP3 on the receiver PC board must be cut e Actual antenna range will vary greatly depending on the operating environment oo SECO LARM U S A Inc ENFORCER Three and Four Channel RF Receiver Sample Applications Positive Output Negative Output Positive Power Source Negative Power Source NO Positive Power Output NO Negative Power Output Power for receiver Power for receiver Typical N C Application Typical N O Application SD 996C NUQ Electric Door Strike E 941SA 1200 Electromagnetic Lock N C Application with Independent Power Sources N O Application with Independent Power Sources DC Power 90 o9 SD 996C NUQ Electric Door Strike JAC Power E 941SA 1200 Source Source Electromagnetic Lock Specifications ae Screw terminals with NO NC COM per chan
6. n is continuously pressed even for short periods of time the receiver may lose the transmitter s signal and turn the relay OFF amp e Press the programming mode switch once to program a channel s output mode That channel s LED will flash a number of times equal to the output mode that it is in Timed Output To change modes press the desired channel s 1 flash mode button Each press moves to the next mode in the sequence shown in the diagram to the right Latch Output After changing modes count the number of times 3 flashes the channel LED flashes to verify the channel is in the correct mode e The programming procedure for each channel is Toggle Output 2 flashes Validity Output the same 4 flashes in programming press the programming mode NOTE For a diagram of the PC board including the location switch again of the mode buttons please see Overview page 3 2 SECO LARM U S A Inc ENFORCER Three and Four Channel RF Receiver Overview SW SW2 SW3 CH 3 Mode switch CH 4 Mode switch 4 Channel models only CH 2 Mode switch Programming mode switch CH 1 Mode switch Time programming DIP switch a a NOI ON ez TIMER 1 2 3 4 5 K r OFF MODE SWITCH Off Off On Off On Off On ci A mi A n w db db db d Mw mMm a me j e D IE m 7 g N ee da 172 166 g2 s ECBECB If an opti
7. nel 5 3 x3 9 x1 1 135x100x27 5mm Compatible Transmitters Operating frequency 315MHz 433 92MHz Fixed Code 68 billion codes SK 919 Series Fixed Code SK 939 Series Fixed Code CODEBUMP 18 quintillion 1 8x1019 codes SK 917 Series CODEBUMP SK 937 Series CODEBUMP WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual deve
8. onal antenna is used LP3 must be cut and the antenna slot on the receiver case must be chipped off to accommodate the extended range antenna wire Power Input 11 24 VAC VDC Channel 1 Channel 2 Channel 4 4 Channel models only Channel 3 PC Board shown Remove the front cover of the receiver to access the mode buttons and terminal block Transmitter Programming Button Operation One per Channel Clearer Press and hold the transmitter programming button for three seconds or more then when the Y LED starts flashing press again for three seconds to delete all previously learned codes Resetiahed outi If this channel was programmed for latch output once the relay is turned ON with a transmitter P button press the transmitter programming button of that channel once to turn the relay OFF demond Press and release the transmitter programming button to show the number of codes stored The ry CisPlay LED will flash a number of times corresponding to the number of codes stored LED Indication One per Channel Steady ON Senses signal from a transmitter button in normal operation or indicates a transmitter button s y code already exists in the receiver s memory during code learning In the code learning mode or channel memory display mode or during the programming channel Fast flash output mode One flash A transmitter button code was learned or the relay is in timed output mode Two flashes All previous
9. that meet the growing demand for multi channel receivers with multiple and independently controlled output modes RF receivers can be used to control a variety of home automation devices such as garage door openers lights motorized gates lifts or other devices remotely These receivers are compatible with both fixed code and code hopping transmitters Code hopping transmitters such as SECO LARM CODEBUMP transmitters change codes every time transmitter sends a signal for extra security See page 4 of this manual for a list of compatible transmitters Installation Notes 1 Mount the receiver out of sight in a location where it is not exposed to the weather or moisture and where it is not surrounded by metal Metal will block the RF signal resulting in a reduced range 2 For best range pull the antenna wire as long and straight as possible If the receiver receives interference from local RF activity e g an airport or military base the antenna wire can be folded DO NOT CUT THE ANTENNA WIRE ENFORCER Three and Four Channel RF Receiver Code Learning a New Transmitter Button Each receiver channel can learn the codes of up to 15 different transmitters on a first in first out basis Below is the procedure for code learning a new transmitter button The same procedure applies to each of the receiver s channels Press the transmitter programming button of the desired channel to be programmed for 3 seconds or more The channel

Download Pdf Manuals

image

Related Search

Related Contents

Wireless 2D Scanner  Manual del Usuario  quadriga service manual do not copy nor distribute  0150-0203G Generic WaveReader User Manual.book  Inhalt - STEP Systems  EVOKE-1 XT Tri-Band Owners Manual  2gBPummING    Teclado Numérico/Lector de proximidad/Controlador  AMX TPI-PRO-DVI  