Home

Sanyo VCC-5974 User's Manual

image

Contents

1. gt LJ SNEXT PAGE END im Press the CURSOR A W button to select APERTURE get it flashing then press the SET button The adjustment sub menu ADJUSTMENT FOR APERTURE will be displayed Press the CURSOR lt d or gt button to adjust the aperture setting 0 to 15 range The on screen marker Bil will move and the adjustment value will flash according to the aperture setting At this time the menu display will be cancelled and you cannot return from this display to the menu display This happens even if the PRESET setting is set to ON To return to the camera display use the CURSOR buttons to select END get it flashing then press the SET button A higher setting value will give a sharp pictures a lower setting value will give a soft pictures Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial values just return the PRESET setting to ON then press the SET button when finished Refer to step 3 on page 15 English 25 MENU FOR ADJUSTMENT AD ON APERTURE 4 ADJUSTMENT FOR APERTURE PRESET OFF END TROUBLESHOOTING Before taking the camera for repairs please check below to make sure that the camera is used correctly If it still does not perform correctly please consult your dealer or a Sanyo Authorized Service Centre II No picture on the moni
2. Genlock Automatic switching 470 TV lines horizontally 350 TV lines vertically 1 0 Vp p 75 ohms composite More than 48 dB AGC switch ON Normal More than 50 dB AGC switch OFF Approx 2 lux with a F 1 2 lens AGC ON Gain Normal 50 IRE Approx 0 9 lux with a F 1 2 lens AGC ON Gain High 50 IRE Manual ON OFF switching Active zone light measuring system Active when using an auto iris lens Manual Electric iris El Auto iris Al switching 2 lux to 100 000 lux F 1 2 lens 2 7 lux to 130 000 lux F 1 4 lens 8 speeds selectable by switches 1 60 1 100 1 250 1 500 1 1000 1 2000 1 4000 1 10000 sec 12 5mm 0 5mm ATW AWB LOCK PRESET MANUAL switching Manual ON Normal 30 dB Hi 36 dB OFF switching Manual ON y 0 45 OFF 1 switching CS mount or C mount with the supplied adaptor Temperature 10 C 50 C Humidity less than 90 no condensation 24 V AC 4 V 60 Hz Approx 3 4 W ens Weight Approx 330 g without HE Dimensions mm 108 5 1 5 99 5 oo 9 12 22 20 UNC Features and specifications are subject to change without prior notice or obligations English 29
3. camera ID 123AB Press the CURSOR buttons to select the desired alphanumeric character or symbol i e S then press SET The first or character in the camera ID will change to S Repeat the same method to enter the desired camera ID maximum of 6 characters or symbols Note The symbol indicates a blank space When entered a camera ID it will be displayed as a blank space 5 When finished entering the camera ID Press the CURSOR or gt button to select MENU get it flashing then press the SET button to return to the MENU FOR ADJUSTMENT display 6 To correct the entered camera ID repeat steps 2 to 5 7 when finished Press the CURSOR A or W button to select END get it flashing then press the SET button to return to the normal camera display MENU FOR ADJUSTMENT CAMERA ID 20N APERTURE TEN 1 CAMERA ID SETTING NNNM CAMERA ID 15 2222222 CAMERA ID SETTING ABCDEFGHI JKLM NOPQRSTUVWXYZ 0123456789 5 CAMERA ID IS 222222 CAMERA ID SETTING ABCDEFGHI JKLM NOPQRSTUVWXYZ 0123456789 MENU FOR ADJUSTMENT CAMERA ID ON APERTURE WRITE PROTECT ON PREVIOUS PAGE END 24 English ADJUSTMENTS 7 APERTURE 1 Press the CURSOR or W button to select NEXT PAGE get it flashing then press the SET button The second page of the MENU FOR ADJUSTMENT will be displayed CURSOR s SHUTTER 60 WRITE PROTECT OFF
4. indoors fluorescent lighting 5100 K MODE 3 Can be set for outdoors sunlight 5100 K MANUAL Set to the initial value The value can be changed manually in the adjustment sub menu see page 22 English 11 ON OFF Table 1 AWB LOCK E Backlight compensation BLC setting The backlight compensation ON OFF is set using the BLC ON OFF switch 9 in the camera setup section ON Default setting backlight compensation function on However depending on the camera installation location and conditions of use if the backlight compensation function need to be set with the BLC switch set to ON press the SET button to select one of PRESET 1 2 or MANUAL 1 2 modes indicated below PRESET 1 Basic setting see Fig 1 When the subject is dark and moving within the image the brightness control is done independently for the 5 windows W 0 4 This setting is recommended when the subject will be moving across or within the image PRESET 2 Basic setting see Fig 2 The windows are regrouped in 2 sections W 1 and 4 and W 0 2 and 3 and the lens iris is set automatically so that the backlight correction is optimum for the section composed of windows W 1 and 2 This setting is recommended when the subject will be centred in the image MANUAL 1 or MANUAL 2 Fig 1 3 The size and position of window W 4 and the windo
5. more and connect as shown by the illustration CAUTION To prevent camera and or AC adaptor failure pay close attention to polarity when making the connections To prevent fire hazard any UL listed wire rated VW 1 should be used for the 24 V AC cable input terminal 6 English PARTS NAMES E Flange back adjustment If the pick up surface is not correctly positioned with relation to the lens focal point the picture will be out of focus in particular when using auto iris power zoom lenses sold separately If that is the case adjust the flange back position as described below 1 Using a screwdriver loosen the FLANGE BACK LOCK 12 ab 1LocKk screw 2 i O O Set the zoom lens to the maximum telephoto position set 1 3 the focus using the focus ring on the lens 2 Set the zoom lens to the maximum wide angle position set the focus using the FLANGE BACK ADJ screw 3 Repeat steps 2 and 3 until the image stays in focus when changing from a telephoto shot to a wide angle shot When the setting is complete tighten the FLANGE BACK LOCK screw MOUNTING THE LENS Check the lens mount Do not use a lens if the length L is more than 5 mm That p may damage the camera and prevent proper installation L Bi Installation of DC type auto iris lens sold separately A 1 3 inch CS mount type lens without EE amplifier circuit that only uses a DC
6. or modifications not expressly approved by Sanyo may void the user s authority to operate this camera 2 English PRECAUTIONS Bl In case of problem Do not use the camera if smoke or a strange odour comes from the unit or if it seems not to function correctly Disconnect the power cord immediately and consult your dealer or a Sanyo Authorized Service Centre Do not open or modify Do not open the cabinet as it may be dangerous and cause damage to the unit For internal settings and repairs consult your dealer or a Sanyo Authorized Service Centre Do not put objects inside the unit Make sure that no metal objects or flammable substance get inside the camera If used with a foreign object inside it could cause a fire short circuits or damages If water or a liquid gets inside the camera disconnect the power cord immediately and consult your dealer or a Sanyo Authorized Service Centre Be careful to protect the camera from rain sea water etc Be careful when handling the unit To prevent damages do not drop the camera or subject it to strong shock or vibration Bl Install away from electric or magnetic fields If installed close to a TV radio transmitter magnet electric motor transformer audio speakers the magnetic field they generate will distort the image Protect from humidity and dust To prevent damages to the camera do not install it where there is greasy smoke or steam whe
7. power source This camera can receive the A I LENS switch to the DC type a CS mount type lens without the need of an adaptor If the lens plug shape or wiring does not correspond please install the supplied plug as indicated in the pin layout table English 7 MOUNTING THE LENS Bi Installation of a VIDEO type auto iris lens sold separately A 1 2 or 2 3 inch C mount type lens with EE amplifier circuit that uses the video signal and a DC power source 1 Remove the lens mount cap 2 Attach the supplied mount adaptor A to the auto iris lens B then install the assembly on the camera 3 Connect the lens plug to the LENS connector on the side of the camera If the lens plug shape or wiring does not correspond to the specifications below connect the supplied plug as indicated When using lenses from other makers make sure that the pins connections in the plug correspond to the ones of the camera Refer to the lens specifications to check the pins connections in the plug A e V f they are different than indicated remove the original plug and connect the supplied plug according to the 4 diagram M poo 4 Set the A I LENS switch in the camera setup section to the i VIDEO position Pin layout DC type lenses VIDEO type lenses gt gt Brake coil 12 V DC 50 mA max M a Br
8. 6 MENU DISPLAY a 27 SPECIFICATIONS sse 29 ACCESSORIES C mount adaptor 5 1 pc The C mount adaptor must be used to be able to install a C mount lens on the camera Lens iris plug 4 1 pc English 1 FEATURES Builtin interline transfer method 1 3 CCD approx 410 000 picture elements Low smear anti blooming low lag no burning and no geometric distortion using the CCD solid state image device 10096 solid state components giving excellent immunity to shock and vibration Not subject to interference from magnetic or electrostatic fields High sensitivity minimum required illumination is 0 9 lux F1 2 AGC Gain High incandescent lighting Horizontal resolution more than 470 TV lines Power supply 24 V AC operation INFORMATION TO USER Sa fety Guard This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide THIS SYMBOL INDICATES THAT THERE ARE IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS reasonable protection against harmfu IN THE LITERATURE interference in a residential installation ACCOMPANYING THIS UNIT This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the WARNING instructions may cause harmful TO
9. ATW 51 10 AGC ON SHUTTER 60 SAIS ul ADJUSTMENT FOR Al WRITE PROTECT L O IRIS LEVEL NEXT PAGE END 4 9 23 BLC ADJUSTMENT t SW9 ON OFF UP SOND 4 S MENU FOR ADJUSTMENT CAMERA ID ZoN APERTURE WHITE BALANCE SETTING SW7 8 all ON ADJUSTMENT FOR WB u e r DER ON OFF Nur WRITE PROTECT ON PREVIOUS PAGE END WB PRESET 1 mmu gt AE gt PEE OFF ON i MANUAL all OFF ADJUSTMENT FOR WB GAIN R H 09 gt 86 lB AGC SETTING r SW6 ON OFF cem Te lol 4 9 Gui lll SHUTTER SETTING SW1 2 3 all OFF 1 60 sec 1 5602 r gt OFF OFF ON AT ON OFF ON OFF ON OFF gt ON ON OFF p AT OFF ON ON e gt DDD ON ON ON Tr ON OFF OFF s Li ll CAMERA ID SETTING ts CURSOR button ON OFF UP SONS ui as _ APERTURE ADJUSTMENT t SET button push SNMP J APERTURE rere English 27 31 3 ADJUSTMENT FOR VBS PHASE H SYNC PHASE H lt 9 8 280 4 gt 280 SC 4 8 0 gt 90 ADJUSTMENT FOR BLC IRAN PI BLC MODE PRESETi lt STUN SBLC LEVELS a ee ADJUSTMENT FOR BLC BLC LEVEL ADJUSTMENT FOR VS gt TN p D TU ADJUSTMENT FOR L L V SYNC PHASE 4 E 518 A
10. DJUSTMENT FOR BLC SIZE ADJUSTMENT FOR BLC Peers 2222 2 gt 15 POSITION OFFSET R g 0 gt A B lt g 255 WINDOW WEIGHTING gt OFFSET wo R 4N gt 29 wi w2 w3 B lt N 189 W4 F1X OFFSET R g gt 7 B 4 m 255 GAMMA _ ON GAMMA OFF AGC GAIN NORMAL allt GH AGC GAIN NORMALE gt CAMERA ID SETTING NNI CAMERA ID IS 7222222 runes gt ADJUSTMENT FOR APERTURE CAMERA ID SETTING ABCDEFGH I JKLM NOPQRSTUVWXYZ 0123456789 MENU gt CAMERA ID IS 28 English SPECIFICATIONS II Camera Scaning system Interlace Image device Picture elements Effective picture elements Synchronizing system External sync Resolution Video output level Video S N ratio Minimum required illumination incandescent lighting Backlight compensation Iris function Electronic iris range Electronic shutter Flange back White balance Gain control Gamma correction Lens mount Environmental conditions Power supply Power consumption NTSC standard TV system 525 TV lines 30 frames sec PLL 2 1 interlace 1 3 inch solid state image device CCD 811 H x 508 V 768 H x 494 V Internal sync Line lock manually switchable External sync VBS or VS signal
11. MENT FOR BLC will be displayed ON CURSOR m SET MENU FOR ADJUSTMENT t gt gt Q SYNC INT gt OFF F m IRIS Al BLC ANI Press the CURSOR 4 or gt button until MANUAL 1 is selected then press the SET button The adjustment sub menu SIZE will be displayed ADJUSTMENT FOR BLC gt NNI BLC MODE MANU d 1 PRESET1 PRESET2 MANUAL 1 MANUAL 2 ALI vas Press the CURSOR buttons to set the size of the area then press the SET button The adjustment sub menu POSITION will be displayed CURSOR C CURSOR ADJUSTMENT FOR BLC ADJUSTMENT FOR BLC SIZE gt SIZE gt gt Gi uj CURSOR Y Press the CURSOR buttons to move up down right left the area to the desired position then press the SET button The adjustment sub menu WINDOW WEIGHTING will be displayed CURSOR ADJUSTMENT FOR BLC POSITION The WINDOW WEIGHTING default values are W0 1 W1 1 W2 3 W3 3 WA 15 the value for W4 is fixed to 15 and cannot be modified ADJUSTMENT FOR BLC Pn PDA BLC MODE PRESET 1 nd ADJUSTMENT FOR BLC SIZE ADJUSTMENT FOR BLC POSITION WINDOW WEIGHTING sla wt w2 3 w3 3 W4 FIX 15 PRESET END ADJUSTMENTS 5 Press the CURSOR A or W button to select the desired window get its value f
12. PREVENT THE RISK OF FIRE OR interference to radio communications ELECTRIC SHOCK DO NOT EXPOSE THIS However there is no guarantee that APPLIANCE TO RAIN OR MOISTURE interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna For the customers in Canada This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Increase the separation between the equipment and receiver Connect the equipment into an outlet Pour la client le canadienne on a circuit different from that to which Cet appareil numerique de la Classe B respecte the receiver is connected toutes les exigences du Reglement sur le Consult the dealer or an experienced material brouilleur du Canada radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the This installation should be made by a qualified following two conditions 1 This device service person and should conform to all local may not cause harmful interference and codes 2 this device must accept any interference received including interference that may cause undesired operation Changes
13. SANYO INSTRUCTION MANUAL VCC 5974 COLOR CCD Camera About this manual Before installing and using the camera please read this manual carefully Be sure to keep it handy for later reference SANYO INDUSTRIAL VIDEO COLOR VIDEO CAMERA LIMITED WARRANTY OBLIGATIONS In order to obtain warranty service the product must be delivered to and picked up from an Authorized Sanyo Service Center at the user s expense unless specifically stated otherwise in this warranty The names and addresses of Authorized Sanyo Service Centers may be obtained by writing to SFS Corporation SFC s warranty administrator at any of the addresses listed below or by calling toll free 1 800 421 5013 New Jersey Office 210 Riser Road Little Ferry NJ 07643 LAf g 4213 3 43 621 apick4Af nSzeYTy sE eg E 4213 3 43 621 5 gUci4213 3wtrsey Off NDUSTRIAL c or r ey h hElcRso Depending on the conditions of use installation and environment please be sure to make the appropriate settings and adjustments If you need help with installation and or settings please consult your dealer CONTENTS INFORMATION TO 2 PRECAUTIONS 3 PARTS NAMES 4 MOUNTING THE LENS 7 CONNECTIONS 9 SETTINGS 10 USING THE ON SCREEN MENUS 13 ADJUSTMENTS a 14 TROUBLESHOOTING 2
14. SET MODE 1 du ADJUSTMENT FOR WB OFFSET 4 2 MANUAL setting adjustment 1 Set the WB switches to the MANUAL mode both switches 7 and 8 to OFF ADJUSTMENTS 5 AGC 1 Set the AGC switch 6 to ON The on screen setting for AGC will automatically switch to ON Press the CURSOR A or W button to select the on screen ON setting get it flashing then press the SET button The adjustment sub menu will be displayed 2 setting the GAMMA Press the CURSOR or gt button to select ON or OFF according to the conditions described below ON 0 45 For natural looking images The image signal is compressed and this setting is recommended under normal conditions OFF 1 The image signal is not compressed This setting is recommended when processing the images When finished setting the gamma press the CURSOR W button 6 CAMERA ID 1 Press the CURSOR amp or W button to select NEXT PAGE get it flashing then press the SET button The second page of the MENU FOR ADJUSTMENT will be displayed Refer to page 13 CURSOR SET SHUTTER 60 WRITE PROTECT ON tm 277 2 With the CAMERA ID ON setting flashing press the SET button The sub menu CAMERA ID SETTING will be displayed The camera ID will be displayed If no ID has been previously 3 To change or enter a camera ID press the SET button again The input sub menu CAMERA ID SETTING will be displayed 4 Example To enter the
15. ake coil Not used 8 Drive coil Video output 1 0 Vp p high S impedance Drive coil Ground for video signal and DC power 8 English MOUNTING THE LENS Compatible auto iris lenses 1 3 inch Sanyo DC type lens 1 2 or 2 3 inch VIDEO type lens VCL CS8LY Standard angle f 8 mm Standard angle f 9 mm VCL CSALY Wide angle f 4 mm Telephoto angle f 12 mm VCL CS2LY Ultra wide angle f 2 8 mm More telephoto angle f 16 mm Wi If using a VIDEO type auto iris lens Set the ALC and LEVEL controls on the lens to adjust the iris Normally the ALC volume should be turned all the way to Av Average Depending on the type of lens used the lens may not perform properly In such a case adjust the LEVEL volume on the lens casing to correct CONNECTIONS Basic connection for monitoring or recording The peripheral devices VCR monitor lens etc and cables are sold separately 1 Make the video signal connection between the camera and the monitor or time lapse VCR 2 Insert the plug of this power cord into a wall outlet The POWER indicator A will light Adjust the picture on the monitor using the Brightness and Contrast controls Coaxial cable type and maximum length pa Cable type RG 59U 3C 2V 250 m maximum i Cable type RG 6U 5C 2V 500 m maximum 4h i Cable type RG 11U 7C 2V 600 m maximum i CAUTION The RG 59U type
16. cable should not be run through electrical I e a conduits or through the air lt Using CCTV Video grade coaxial cable Video signal connections gt gt gt VIDEO IN 55 VIDEO OUT English 9 SETTINGS The illustration shows the factory default settings for the switches in the camera setup section Depending on the camera installation location and conditions of use it may be necessary to select other settings without having to make adjustments The selected settings can be confirmed using the on screen menu If adjustments are required they can be entered using on screen adjustment sub menus see ADJUSTMENTS page 14 HHBHBHB 5 6 7 8 9 10 INT OFF OFF 7 8 OFF EI E High speed electronic shutter ES setting Normally the three speed setting switches 1 2 and 3 for the high speed electronic shutter are all set to the OFF position This sets the electronic shutter speed to 1 60 sec The three switches in the camera setup section can be set as indicated in table A to select one of the 8 speeds available Notes When using the high speed electronic shutter the BLC switch must be set to the OFF position Using the high speed electronic shutter indoors with low lighting will give darker pictures In such a case add some lights to make sure the lighting is sufficient If
17. e adjustment sub menu ADJUSTMENT FOR will be displayed Al CURSOR SET MENU FOR ADJUSTMENT QY gt SYNC QNT gt EI IRIS SAIS BLC CN 2 Press the CURSOR lt or p gt button until the desired iris level is obtained The on screen marker Bl will move and the adjustment value will flash according to the iris level setting Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial value just return the PRESET setting to ON then press the SET button 3 when finished Refer to step 3 on page 15 Notes f IRIS is set to El electronic iris mode the SHUTTER setting function will not operate When the AGC switch is set to OFF the IRIS cannot be set to El English 17 ADJUSTMENT FOR AI IRIS LEVEL I 4 8 60 223 ADJUSTMENT FOR Al IRIS LEVEL Example When the image is dark press the CURSOR or P button to move the on screen marker close to the position indicated above 3 BLC 3 1 Setting the light measuring area 1 2 3 4 Note characteristics size position and distribution for the MANUAL 1 setting Set the BLC switch 9 to ON The onscreen setting for BLC will automatically switch to ON Press the CURSOR A or W button to select the on screen ON setting get it flashing then press the SET button The adjustment sub menu ADJUST
18. hen press the SET button The adjustment sub menu BLC LEVEL will be displayed ADJUSTMENT FOR BLC BLC MODE BLC LEVEL ar ee ee es PRESET1 4 While looking at the image on the monitor press the CURSOR lt or gt button until the BLC level is obtained The on screen marker I will move and the adjustment value will flash according to the BLC level setting Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial value just return the PRESET setting to ON then press the SET button 5 When finished Refer to step 3 on page 15 Note The BLC level adjustments should be entered under the PRESET 1 or MANUAL 1 settings The BLC level adjustments entered under the PRESET 2 or MANUAL 2 settings will not be effective ADJUSTMENT FOR BLC A se BLC MODE PRESET1 E E ADJUSTMENT FOR BLC BLC LEVEL ute 4 gt 7158 ADJUSTMENT FOR BLC BLC LEVEL PRESET END Example If the backlight compensation BLC correction is insufficient press the CURSOR or button to move the on screen marker close to the position indicated above 20 English ADJUSTMENTS 4 WHITE BALANCE 4 1 PRESET MODE 2 indoors fluorescent lighting setting adjustment 1 Set the WB switches to the PRESET mode switch 7 to OFF and switch 8 to ON The on screen setting for WHITE BALANCE will automatically switch to PRESET Pres
19. ion High speed electronic shutter All OFF 1 60 sec switches ES Internal Line lock switch SYNC INT Auto gain control switch AGC ON White balance switch WB all ON ATW B 2 3 4 5 7 A 9 A m 1 2 3 WT OF OF 7 8 OFF El Backlight compensation switch ON BLC Electronic iris EI Al Auto iris Al switch Auto iris lens switch LENS DC Notes When using a 1 2 or 2 3 inch C mount VIDEO with EE internal amplifier auto iris type lens set the A I LENS switch to the VIDEO position The settings entered in the camera setup section can be displayed using the on screen menu f not using an autoris lens make sure the BLC switch is set to OFF Video output connector VIDEO OUT BNC type Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector External sync composite video signal input connector VBS IN BNC type Connect to this connector the synchronizing signal output from a synchronizing signal device or the composite signal of a video distributor D Power indicator POWER Comes on when the power to the camera is on B 24 V AC input terminal 24 V AC GND With this camera use only the 24 V AC power adaptor model No VPT 115 available from Sanyo Power supply connections Use a 3 wire grounded cable 22 AWG or
20. lashing then press the CURSOR lt 4 or gt button to set the desired value maximum 15 for each of the 4 windows 0 1 2 and 3 Example WO 5 W1 5 W2 10 and W3 10 WINDOW WEIGHTING WINDOW WEIGHTING WINDOW WEIGHTING wo wi 35 w2 gt w3 w3 3 W4 FIX W4 FIX 15 PRESET PRESET END END CURSOR CURSOR CURSOR CURSOR CURSOR A i A ANZ ANE lt E lt P lt lt Y y Y Y v 1 gt 2 gt 3 gt 4 gt 5 Mr 3 4 5 A hj 6 7 8 9 10 WINDOW WEIGHTING w3 W4 FIX PRESET END 2 2 4 P lt gt Y v n 8 9 410 Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial value just return the PRESET setting to ON then press the SET button 6 when finished Refer to step 3 on page 15 English 19 3 2 BLC level adjustment for the PRESET 1 setting 1 Set the BLC switch 9 to ON The on screen setting for BLC will automatically switch to ON Press the CURSOR A or W button to select the on screen ON setting get it flashing then press the SET button The adjustment sub menu ADJUSTMENT FOR BLC will be displayed ON CURSOR MENU FOR ADJUSTMENT 1 gt Mx gt SYNC INT gt j IRIS Al uid E EM BLC 2 Press the CURSOR or gt button until PRESET 1 is selected 3 Press the CURSOR W button to select BLC LEVEL get it flashing t
21. lly switch to L L Press the CURSOR A or W button to select the on screen L L setting get it flashing then press the SET button The adjustment sub menu ADJUSTMENT FOR L L will be displayed LL CURSOR SET MENU FOR ADJUSTMENT 1 gt gt Q SYNC INT ify Be ON 2 Switch the display on the monitor from camera 1 to camera 2 Press the CURSOR or gt button until the vertical sync phase is obtained The on screen marker Bil will move and the adjustment value will flash according to the vertical sync phase setting CURSOR Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial value just return the PRESET setting to ON then press the SET button 3 when finished D Press the CURSOR A or W button to select END get it flashing then press the SET button to return to the normal camera display or 2 Press the CURSOR A or W button to select MENU get it flashing then press the SET button to return to the MENU FOR ADJUSTMENT display English 15 ADJUSTMENT FOR L L V SYNC PHASE ADJUSTMENT FOR L L V SYNC PHASE x 4 0 8 7415 1 1 2 VBS phase adjustment 1 Connect a VBS signal source to the VBS IN connector on the camera The on screen setting will automatically switch to VBS Press the CURSOR A or W button to select the on screen VBS setting get it flashi
22. nect the camera to the monitor then press the SET button for about 3 seconds to display the on screen menu Cursor button CURSOR A Press this button to move the cursor up Press this button to move the cursor to the right or to turn the settings ON OFF etc lt Press this button to move the cursor to the left or to turn the settings ON OFF Press this button to move the cursor down Flange back lock screw FLANGE BACK LOCK Flange back adjustment screw FLANGE BACK ADJ Lens mount cap The cap is installed to protect the lens mount section Remove the lens mount cap before installing a lens sold separately Q Camera installation bracket The bracket can be fixed at the top or bottom of the camera When fixing the bracket be sure to use the longer screws and install the shorter screws on the opposite side to seal the openings CAUTION When installing the camera support select a location that can support the total weight of the camera and accessories 4 English PARTS NAMES Camera setup section under the cover This unit factory settings are as indicated below These settings are for when using a 1 3 inch CS mount DC without EE internal amplifier type lens However if due to installation conditions or environment the settings may need to be modified for best results see SETTINGS To access the controls remove the cover fixing screw then remove the cover Control name Posit
23. ng then press the SET button The adjustment sub menu ADJUSTMENT FOR VBS will be displayed CURSOR ADJUSTMENT FOR VBS SET MENU FOR ADJUSTMENT PHASE A ue gt G SYNC vss gt 9 g 280 IRIS At mos 9 8 72803 E BLC ON SC 4 N 9 gt 90 Press the CURSOR lt or gt button to adjust the horizontal phase The on screen marker Bil will move and the adjustment value will flash according to the horizontal phase setting When finished setting the horizontal phase H press the CURSOR W button to select the sub carrier SC phase Press the CURSOR or gt button to adjust the sub carrier SC phase The on screen marker Il will move and the adjustment value will flash according to the sub carrier phase setting Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial values just return the PRESET setting to ON then press the SET button when finished Refer to step 3 on page 15 Note If using a VS sync signal the H sync phase adjustment is made by following the same method as described for the VBS phase adjustment 16 English ADJUSTMENTS 2 IRIS 2 1 Auto iris level adjustment 1 Set the IRIS switch 10 to Al The on screen setting will automatically switch to Al Press the CURSOR A or W button to select the on screen Al setting get it flashing then press the SET button Th
24. re the dampness may get too high or where there is a lot of dust English 3 Protect from high temperatures Do not install close to stoves or other heat generating devices such as spotlights etc or where it could be subject to direct sunlight as that could cause deformation discoloration or other damages Be careful when installing close to the ceiling in a kitchen or boiler room as the temperature may raise to high levels Install where the temperature range will stay between 10 C and 50 C no condensation II Cleaning Dirt can be removed from the cabinet by wiping it with a soft cloth To remove stains wipe with a soft cloth moistened with a soft detergent solution and wrung dry then wipe dry with dry soft cloth Do not use benzine thinner or other chemical product on the cabinet as that may cause deformation and paint peeling Before using a chemical cloth make sure to read all accompanying instructions Make sure that no plastic or rubber material comes in contact with the cabinet for a long period of time as that may cause damage or paint peeling PARTS NAMES Shorter screws M3 x 4 Longer screws M3 x 6 8 Camera mounting screw hole 1 4 20 UNC Lens iris output connector 4 pin This 4 pin connector is used to send the DC control signal and power supply to an auto iris type lens Auto white balance push lock button AWB LOCK Menu setting button SET Con
25. s necessary to enter new settings or adjustments press the CURSOR A or W button to select the WRITE PROTECT function setting then press the CURSOR 4 or gt button to select OFF then press the SET button CURSOR CURSOR SET A ify 7 CONTENTS OF ADJUSTMENTS 1 SYNC 1 1 V sync phase adjustment 15 1 2 VBS phase adjustment esee 16 2 IRIS 2 1 Auto iris level adjustment 17 3 BLC 3 1 Setting the light measuring area characteristics size position and distribution for the MANUAL 1 setting 18 3 2 BLC level adjustment for the PRESET 1 setting 4 WHITE BALANCE 4 1 PRESET MODE 2 indoors fluorescent lighting setting adjustment interire akaqa 21 4 2 MANUAL setting adjustment 22 f c c O a 23 6 CAMERA ID oum Rene 24 4 APERTURE ime 25 Menu 1 MENU FOR ADJUSTMENT B WHITE BALANCE AGC SHUTTER WRITE PROTECT NEXT PAGE 14 English ADJUSTMENTS 1 SYNC 1 1 V sync phase adjustment When using a camera switcher to connect 2 cameras or more to one monitor there may be a vertical roll of the images when switched In such a case set as described below 1 set the SYNC switch 4 to LLL The on screen setting will automatica
26. s the CURSOR A or W button to select the on screen PRESET setting get it flashing then press the SET button The adjustment sub menu ADJUSTMENT FOR WB will be displayed WB CURSOR MENU FOR ADJUSTMENT SYNC INT ta Ht lt gt IRIS Al gt 4 BLC SN 1 7 7 8 1 tn WHITE BALANCE PRESETS wal AGC oN 2 Press the CURSOR lt or gt button until MODE 2 is selected then press the SET button The adjustment sub menu OFFSET will be displayed ADJUSTMENT FOR WB gt MIX WB PRESET MODI 0 2 Press the CURSOR lt or gt button to adjust the R red offset The on screen marker Bl will move and the adjustment value will flash according to the red offset setting When finished setting the red offset press the CURSOR V button to select B blue Press the CURSOR or gt button to adjust the B blue offset The on screen marker will move and the adjustment value will flash according to the blue offset setting Note When an adjustment is made the PRESET setting will automatically switch to OFF To return to the initial values just return the PRESET setting to ON then press the SET button When finished Refer to step 3 on page 15 Note The OFFSET settings for MODE 1 and MODE 3 are made by following the same method as described for MODE 2 English 21 ADJUSTMENT FOR WB v A WB PRE
27. the lighting is very bright pay attention to the light angle in order to avoid or minimize the smear phenomenon effect f IRIS is set to El electronic iris mode then the high speed electronic shutter speed will not correspond to the set speed SETTINGS ll Automatic Gain Control AGC setting The automatic gain control can be turned ON or OFF using the AGC ON OFF switch 6 in the camera setup section ON Auto gain control function on setting used under normal conditions see page 23 GAMMA ON 0 45 OFF 1 AGC GAIN NORMAL 30 dB HIGH 36 dB OFF Fixed gain Note When the AGC switch is set to OFF the GAMMA and backlight compensation are automatically set to OFF and the IRIS is set to Al E White balance WB setting Under normal conditions the white balance is set to ATW Auto Tracing White Balance However depending on the camera installation location and conditions of use the white balance mode can be set using the two WB switches 7 and 8 in the camera setup section see table 1 ATW Initial setting The initial value cannot be changed LOCK The white balance is done automatically while the AWB LOCK button is pressed then it is locked when the button is released PRESET The white balance is done according to one of the three preset modes The preset modes can be adjusted manually in the adjustment sub menu see page 21 MODE 1 Setting for incandescent lighting 2660 K MODE 2 Setting for
28. tor screen Are all the signal connecting cables correctly connected Is the lighting sufficient Has the lens cap been removed Is the lens type DC or VIDEO correctly selected Depending on the type of lens the A I LENS switch must be set accordingly Is the iris control correctly set A When using a DC type lens the CORSOR button should be adjusted B When using a VIDEO type lens the LEVEL volume on the lens should be adjusted Uv he power turned on to all connected devices Is the voltage correct v Uv v The picture is not clear Is the monitor correctly adjusted Is the flange back position correctly set Is the lens focus correctly adjusted Are the lens surfaces clean If there is dust or finger prints on the lens the image quality will deteriorate To clean the lens use a soft cloth or a commercially available lens cleaning set SERVICE This camera is a precision instruments and if treated with care will provide years of satisfactory performance However in the event of a problem the owner is advised not to attempt to make repairs or open the cabinet Servicing should always be referred to your dealer or Sanyo Authorized Service Centre 26 English MENU DISPLAY ll SYNC ADJUSTMENT SWA LL INT 4 gt GX insert VBS signal 08 insert VS signal MENU FOR ADJUSTMENT gt st TANE IRIS ADJUSTMENT M 0 BLC ON gt WHITE BALANCE
29. tup section is changed the corresponding sub menu is displayed To adjust the values or settings press the CURSOR or gt button to select the desired value or setting then press the SET button CURSOR SET ANZ Q8 initial values protection WRITE PROTECT ON Default setting The initial values cannot be modified ZS Z Z OFF Press the CURSOR or gt button to select OFF then Y R press the SET button The write protection is cancelled i and the initial values can then be changed CURSOR CURSOR ET 4 To exit the menu Press the CURSOR A or W button to select END get it flashing then press the SET button 5 To switch to the second page of the MENU FOR ADJUSTMENT Press the CURSOR or W button to select NEXT PAGE get it flashing then press the SET button 6 switch back to the first page of the MENU FOR CURSOR ser ADJUSTMENT gt gt Press the CURSOR A or Y button to select PREVIOUS x L PAGE get it flashing then press the SET button 7 To enter a camera ID CAMERA ID See page 24 8 Aperture display APERTURE See page 25 English 13 ADJUSTMENTS To enter settings or adjustments for the camera it must be connected to a monitor The settings and adjustments are made by ways of on screen displays Wl Concerning the WRITE PROTECT function In order to protect the settings and adjustments the WRITE PROTECT function is set to ON If it i
30. ws W 0 4 distribution WINDOW WEIGHTING can be set manually to control a bigger area of the screen e g when the subject will be moving in the screen area and stored under one of the two manual settings OFF Fixed backlight compensation Notes The backlight compensation will operate when using an autoris lens DC or VIDEO type Ifin the MENU FOR ADJUSTMENT AGC is set to OFF the backlight compensation will not operate Bi Iris level setting The iris is set using the IRIS AI Auto lris El Electronic Iris switch 10 in the camera setup section Al Initial setting When using a DC type autoris lens the iris level settings can then be entered in the adjustment sub menu see page 17 El Electronic iris mode setting Note If the AGC switch is set to OFF setting the IRIS switch to El will not set the electronic iris mode W2 10 W4 15 W3 10 Fig 2 WINDOW WEIGHTING w3 FIX PRESET MENU END Fig 3 Al El 12 English USING THE ON SCREEN MENUS Menu 1 Menu 2 MENU FOR ADJUSTMENT MENU FOR ADJUSTMENT SYNC UNT CAMERA ID OFF 7 IRIS AD BLC WHITE BALANCE AGC SHUTTER WRITE PROTECT 5 iN 1 1 To display the menu stl Press the SET button for about 3 seconds The MENU FOR dd NT ADJUSTMENT is displayed 2 To switch between menus and selection gEBBHBBBHB 1 When the setting of a switch in the camera se