Sanyo SPW-K095XH User's Manual

image

Contents

1. Receiver 68 View in direction of arrow Z 1375 Data subject to change without notice Liquid pipe 29 52 Length Approx 570 mm Q Gas pipe 215 88 Length Approx 500 mm Length Approx 450 mm Drain hose VP13 Installation fitting Fitting fixing hole 5 hole or 5 x 13 slot Installation fitting piping wiring inlet 080 Xx jJ IL IL IL I I I X J It X X I It 20 17 bx27 5P 55 55 Receiver View in direction of arrow Z Dimensions mm WALL MOUNTED UNITS CONCEALED FLOOR STANDING UNITS FLOOR STANDING UNITS Tl MEA m V e Option Wired remote controller Wireless remote controller Simplified remote controller RCS TM80BG RCS BH80BG WL RCS KR1AGB Realization of perimeter air co
2. Within 35 Within 35 7 25 type 36 60 type 256 319 Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more 15 mm or more from the lower surface of the body as shown in the figure When the suspension bolt length is long it hits the ceiling panel and installation is not possible SEMI CONCEALED CASSETTE 4 WAY AIR DISCHARGE Option e Wired remote controller e Wireless remote controller eSimplified ePanel did remote controller E ee t RCS SS80BG WL i z PNR XM184EHAB ae RCS TM80BG a RCS BH80BG WL RCS KR1AGB New dimensions 600 x 600 mm suitable for European under ceiling standards Three speed centrifugal fan Anti mould and anti bacteria washable filters Low operating sound Indoor units specifications XMR74EXH56B XMR94EXH56B XMR124EXH56B XMR164EXH56B 220 230 240V 1 phase 50 Hz XMR184EXH56B 22 2 8 3 6 45 5 6 7 500 9 600 12 000 15 000 19 000 kW 25 32 4 2 50 63 BTU h 8 5
3. Power source 220 230 240V 1 phase 50 60 Hz Cooling capacity kV 22 2 8 26 45 56 18 10 6 14 0 16 0 D 7 500 9 600 12 000 15 000 19 000 25 000 36 000 47 800 54 600 67 25 97 4 2 50 6 3 8 0 114 16 0 18 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 39 000 54 600 61 400 Cooling kW 0 094 0 100 0 106 0 096 0 102 0 109 0 180 0 195 0 210 0 312 0 327 0 342 0 308 0 325 0 341 Heating kW 0 082 0 088 0 094 0 084 0 090 0 097 0 168 0 183 0 198 0 300 0 315 0 330 0 296 0 313 0 329 Running Cooling A 0 45 0 46 0 47 0 44 0 45 0 46 0 83 0 86 0 89 1 44 1 45 1 46 1 42 1 43 1 44 amperes Heating A 0 40 0 41 0 42 0 39 0 40 0 41 0 78 0 81 0 84 1 39 1 40 1 41 1 36 1 37 1 38 Type Sirocco fan 1 Sirocco fan 2 Sirocco fan 3 Fan motor ow rate H MIL mimi 10 8 5 7 12 10 5 9 18 15 13 30 26 21 33 30 25 Output kW 0 05 0 07 0 14 alc pa 4969 40 62 50 92 79 122 78 113 Power sound level H M L dB A 40 37 33 41 39 36 45 41 38 49 44 42 51 48 44 Pressure sound level H M L dB A 32 29 26 22 33 30 28 25 38 34 30 27 42 38 33 31 44 40 3 7 33 Height mm STO Dimensions Width mm 700 1000 1480 Depth mm 630 Liquid Flare mm 6 35 9 52 Piping Gas Flare 12 7 15 88 connections Drain piping VP 25 Net weight kg 24 25 97 47 Rated conditions The values in for the external static pressure and operating sound are for use of booster cab
4. Power source 220 230 240V 1 phase 50Hz Cooling capacity kW 22 28 3 6 4 5 56 75S 9 0 10 6 14 0 16 0 BTU h 7 500 9 600 12 000 15 000 19 000 25 000 30 000 36 000 47 800 54 600 Heating kW 2218 32 2 5 0 63 8 0 10 0 16 0 18 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 34 000 39 000 54 600 61 400 Power Cooling kW 0 094 0 100 0 106 0 109 0 102 0 096 0 096 0 102 0 109 0 180 0 195 0 210 0 187 0 203 0 219 0 312 0 327 0 342 0 308 0 325 0 341 input Heating kW 0 082 0 088 0 094 0 097 0 090 0 084 0 084 0 090 0 097 0 168 0 183 0 198 0 176 0 191 0 207 10 300 0 315 0 330 0 296 0 313 0 329 Running Cooling A 0 45 0 46 0 47 046 045 044 044 045 046 083 086 089 088 091 0 144 145 146 142 143 144 amperes Heating A 0 40 0 41 0 42 0 41 0 40 0 39 0 39 0 40 0 41 0 78 0 81 0 94 084 087 090 139 140 141 38 Sirocco fan 1 Sirocco fan 2 Sirocco fan 3 Fan Airflow rate H M L 10 8 5 7 12 105 8 18 15 12 20 17 14 30 26 21 Soy S025 motor Output kW 0 05 0 07 0 14 External static Pa 49 69 40 62 50 92 791122 You Power sound level H M L dB A 40 37 33 41 39 36 45 41 38 45 41 38 49 44 42 51 48 44 Pressure sound level H M L dB A 33 29 26 22 33 30 28 25 38 34 30 27 38 34 30 27 42 38 33 31 44 40 37 33 Height mm ST Dimensio
5. e Wireless remote controller S eWired remote controller ida BH am RCS TRPSOBG WL RCS BH80BG WL RCS TM80BG Simplified remote controller RCS KR1AGB Newly developed DC fan motor with variable speed Drastic reduction of the power input by adoption of a Sirocco fan with a new shape a heat exchanger etc kW 0 21 08 0 074 0 032 J Current 4 series Current 4series model model Weight reduction for all models All models have light weight in the top class of the industry and the installation work also have been improved Body height and depth have been unified for all models and functional design permits clean and good looking installation also for several units 40 9 30 20 10 23 21 ee 4 series 4 series model model 12 16 18 type 36 48 type ll New design with lower operating sound The operating sound has been reduced by max 2 dB A by use of heat exchanger fins and Sirocco fans with a new shape and reduced wind path resistance Model Operation noise 25 type 48 type 43 37 dB A 38 33dB A Realization of the most suitable air flow for heating and for cooling Heating F1 to F5 Cooling F1 to Automatic setting of the blowing angle according to heating or cooling In case of swing operation the flap moves automatically and smoothly in the range from F1 to
6. entire circumference ee ee 290 _ 130 bolt pitch S 8 16 3 2 holes entire circumference F a 4x100 400 500 980 Electric equipment box 4 920 for suspension bolts Suspension bolt pitch 1010 T 55 940 Power source 220 230 240V 1 phase 50 60Hz o kW Je 10 6 14 0 224 28 0 BTU h 25 000 36 000 47 800 76 400 95 500 e kW 8 0 16 0 250 BTU h 27 000 39 000 54 600 85 300 107 500 Power input Cooling kW 0 480 0 505 0 530 0 520 0 545 0 570 0 600 0 660 0 710 0 870 0 900 0 930 152704 5550 45590 Heating KW 0 480 0 505 0 530 0 520 0 545 0 570 0 600 0 660 0 710 0 870 0 900 0 930 1770 950 1390 A 22002 2 2 46 2 46 2 47 2 80 2 90 3 00 4 05 4 06 4 07 6 04 6 06 6 07 Heating A 2292 023 2 46 2 46 2 47 2 80 2 90 3 00 4 05 4 06 4 07 6 04 6 06 6 07 Type Sirocco fan 1 Sirocco fan 2 ETUR Airflow rate H M L m min 23 22 21 30 28 25 36 35 33 56 53 1496 72 70 66 Output kW 0 2 0 35 0 2 2 0 4 2 External static pressure Pa 186 176 167 176 216 Power sound level H M L dB A 55 54 53 56 55 53 58 57 55 59 58 57 62 61 60 Pressure sound level H M L dB A 44 43 42 45 44 42 47 46 44 48 47 46 51 50 49 Height mm 420 450 467 Dimensions Width mm 1065 1428 Depth mm 620 1230 Liquid
7. System signal x 4 Polarity shield wire Prohibition 1 The remote controller cannot be used for ON OFF All other operations are possible from the remote controller The remote controller cannot be used for ON OFF operation mode Prohibition 2 change and temperature setting All other operations are possible from Communication the remote controller Linked system No 3 adapter gt a Linked system No 4 The remote controller cannot be used for operation mode change and SHA KA128AGB Prohibition 3 temperature setting All other operations are possible from the remote controller Prohibition The remote controller cannot be used for operation mode change All other operations are possible from the remote controller System signal x 4 Max 4 links can be connected for Communication adaptor SHA KA128AGB Note Avoid joint use of the AMY system and the intelligent controller on the same indoor outdoor operation line the indoor outdoor operation line Max 64 indoor units x 4 256 units Max 30 outdoor units x 4 120 units mom j Wai in D Dimensions H 260 x W 200 x D 68 mm Power supply AC 100 to 240 V 50 Hz 3 W separate power supply e Required to connect three or more linked wiring systems indoor
8. 730 ceiling opening dimensions 659 suspension bolt pitch Panel center suspension bolt pitch ceiling opening dimensions Data subject to change without notice Dimensions mm Air intake grille Air outlet Ari OA Refrigerant piping liquid pipes 26 35 flared Refrigerant piping gas pipes 212 7 flared Drain connection VP25 outer 32 Power supply inlet Suspension holes 4 12 x 30 slot Wireless remote controller receiver opening lt Dimensions of Filter gt 350 x 241 x 12 x 1 piece SEMI CONCEALED CASSETTE 1 WAY AIR DISCHARGE 29 Our slim model which is only 200mm in depth can air condition spaces with ceiling heights up to 4 2m Ed Option WIDE OPERATION E e Wireless remote controller eWired remote controller z EN RCS TRP80BG WL a ER RCS TM80BG RCS BH80BG WL Simplified remote controller ud FE TUT RCS KR1AGB ePanel PNR LD254GHAB Top industrial capacity to handle ceiling heights up to 4 2m e Attained height ceiling height based on fan motor speed setting m 9 Indoor unit type 9 type 18 type Fan speed setting Ceiling height 25 type Attained heigh
9. COP Inc Hot water Cooling 1 85 1 87 Size Height x Width x Depth 2 248 x 1 800 x 1 000 60 Weight 820 1 580 Starter Amperes Gas 9 31 75 Liquid 915 88 Pipe Balance 2 9 52 Fuel gas R3 4 Bolt thread Exhaust drain 25 Rubber hose Operation sound 58 60 Indoor Outdoor capacity ratio 50 200 Number of connection indoor In case of these combination EGW190M2G2W is able to connect sa W multi system instead of EW190M2G2W 1 Low temp condition Outdoor temperature 2 C 36 W MULTI 190 112 0 127 0 142 0 90 0 91 5 1 01 0 90 0 100 0 103 0 113 0 126 0 143 0 160 0 5 5 106 0 109 5 120 0 134 0 142 0 150 0 28 0 32 0 32 0 36 0 40 0 45 0 50 0 2 20 2 70 2 20 270 2 20 2 70 2 70 2 02 2 10 2 02 2 02 2 02 55 3 08 501 53 2 62 8 69 9 76 6 99 2 1216 64 2 22 lel 79 1 86 0 101 0 116 0 84 1 94 6 952 1037 112 8 2 129 8 1 38 1 97 1 1 39 A 25 1 14 1236 1 35 1 41 1 39 RAS 1 38 1 34 1 97 1 36 1 41 1 39 1 42 1 31 1 24 1 86 65 1 90 1 89 1 92 1 69 IRSA 2 248 x 1 800 100 min distance 1 800 in case of straight installation x 1 000 60 1 580 1 580 1 610 1 610 1 640 1 670 1 700 30 31 75 31 75 9 31 75 31 75 9 38 1 9 38 1 9 38 1 219 05 919 05 1905 219 05 919 05 219 05 619105 9 52 R3 4 Bolt thread 25 Rubber hose 60 60 61 61 61 63 65 50 130 48 Spec
10. ll Discharge opening and flap with new shape The condensate and dirt appearing near the discharge ports of the conventional ceiling cassettes have been reduced gt Current New ceiling cassette The discharged air hits the Upward air flow is suppressed ceiling and causes dirt The flap can be removed easily for washing with water I EET ll Lighter and thinner easier installation S Height 283 mm 7y drain height of approx 850 mm from the ceiling surface The drain height could be increased by approx 350 mm over the conventional value by adoption of a eren high lift drain pump and correspondence to long Up to 850 mm horizontal piping is possible Up to 300 mm Indoor units specifications XM075XH XMO095XH XM125XH XM165XH XM185XH Power source 220 230 240V 1 phase 50 60Hz 22 as 3 6 7 55 7 500 9 600 12 000 15 000 19 000 VERTS teen kW 25 3 2 4 0 5 0 6 3 BTU h 8 500 11 000 14 000 17 000 21 000 Moisture Removal High Liters h 0 2 0 6 1 1 5 1 9 Power input Cooling KW 0 024 0 025 0 025 0 026 0 027 0 027 0 030 0 031 0 031 0 037 0 038 0 038 COT COIS C05 0 017 0 017 0 018 0 020 0 021 0 021 0 029 0 029 0 029 Running amperes Cc 0 16 0 16 0 15 0 18 0 18 0 17 02 020 0 29 0 29 0 28 0130137012 QUIS SOT 0 26 0
11. 4 Discharge around duct adapter flange 3 0 200 Inspection lid 1480 10 7 1560 Electric equipment box Suspension bolt pitch Wind shielding panel lS Suction angle duct flange field supply 33 H 7 f DRY Ld 25 Option e Wired remote controller eWireless remote controller eSimplified remote controller D RCS TM80BG RCS BH80BG WL RCS KR1AGB la The static pressure outside the unit can be W Unified body height of approx 310 mm for all increased models By using the booster cable the static pressure outside the unit Even models with different capacities can be installed can be increased DS smoothly in the ceiling System example An inspection port 450 mm x 450 mm or more is required at the With booster senan e e 62 92 122 113 cable use 69 lower side of the indoor unit body ll Drain pump with increased power Rectangle duct Canvas duct By adoption of a high lift drain pump Up to 300 mm the drain piping rise height could be increased to 785 mm from the ee lower surface of the body ii Intake grille 450 x 450 mm or more Easy maintenance by external installation of the electric equipment box Body electric equipment box Bl Anti mould washable filters included i Indoor units specifications
12. The length of the suspension bolts should be selected so that there is a gap of 30 mm or the ceiling 17 mm or more below the lower surface of the main unit as shown in the bolts is too long it will contact the ceiling panel and the unit cannot be installed figure at right If the suspension w SEMI CONCEALED 4 WAY AIR DISCHARGE Hu SEMI CONCEALED CASSETTE 4 WAY AIR DISCHARGE Option Wired remote controller eWireless remote controller Simplified Panel Air intake chamber remote controller Air intake box RCS SH80BG WL N CMB GS140AGB PNR XD484GHAB d i CS ra Air intake plenum CMB FS140AGB RCS TM80BG RCS KRIAGB Both Air intake plenum and Air intake box is necessary lll Turbo fans and heat exchanger fins with new ll Lighter and thinner easier installation shapes are adopted and the operating sound The top class lightest weight with 26 kg could be reduced by max 6 dB A for type 36 60 body height only 256 mm 7 25 so that installation is S Height 256 mm 45 dB A possible even in narrow ceilings d b Easy fine adjustment of the body suspension 35 height A 30 The four corners of the ceiling panel have adopted 4 series aren 4 series SE 4 series removable corner pockets E Wide reduction of the power consumptio
13. Lack of sufficient space for servicing may prevent the unit from being properly maintained and cared for place that is unsafe for maintenance work If the unit is installed on the roof of a building even if the spot is level and it is not prevented from falling with a guardrail or similar means not only will maintenance work become impossible but the unit may fall or other accident may occur A place where a ladder must be used to access the unit An installation that requires maintenance workers to go up and down a ladder or stairs makes safe and reliable maintenance work not only difficult but dangerous as well A poorly ventilated location If the top side or front of the unit is close to a wall or other obstruction poor ventilation and lack of sufficient air circulation may not only cause trouble but also prevent the unit from operating normally Near a street lamp or tree Insects attracted by street lamps in large numbers and leaves from trees can get sucked into the unit and cause it to malfunction Other locations to avoid Places where chemicals are used Places where the unit will disturb others Near a chimney or exhaust outlet Places exposed to strong winds An installation that has no vibration proof pad Near a wall other than a soundproof wall Places where salt damage may occur and no preventive measures are taken Places with no protection from snow In addition if the area below t
14. Panel Air Discharge PNR XM185 PNR XM185 PNR XM185 PNR XM185 PNR XM185 SPW X075XH SPW X095XH SPW X125XH SPW X165XH SPW X185XH semi Concealed Panel Panel Panel Panel Panel Cassette 4 Way E M PNR XD484GHAB PNR XD484GHAB PNR XD484GHAB PNR XD484GHAB PNR XD484GHAB Air Discharge SPW XMR74EXH56B SPW XMR94EXH56B SPW XMR124EXH56B SPW XMR164EXH56B SPW XMR184EXH56B Semi Concealed Panel Panel Panel Panel Panel Cassette 4 Way an PNR XM184EHA PNR XM184EHA PNR XM184EHA PNR XM184EHA PNR XM184EHA Air Discharge gt t pe d SPW SR74GXH56B SPW SR94GXH56B SPW SR124GXH56B SPW SR164GXH56B SPW SR184GXH56B Semi Conceale Pane Panel Panel Pane Pane Cassette 2 Way Air Discharge PNR S124GHB PNR S124GHB PNR S124GHB PNR S124GHB PNR S124GHB type SPW ADR74GXH56B SPW ADR94GXH56B SPW ADR124GXH56B Semi Concealed Panel Panel Panel Cassette 1 Way PNR AD124GHB PNR AD124GHB PNR AD124GHB Air Discharge LDR type SPW LDR94GXH56B SPW LDR124GXH56B SPW LDR164GXH56B SPW LDR184GXH56B Semi Concealed Panel Panel Panel Panel Slim Cassette PNR LD254GHAB PNR LD254GHAB PNR LD254GHAB PNR LD254GHAB U type Concealed Duct SPW U075XH SPW U095XH SPW U125XH SPW U165XH SPW U185XH UR type Concealed Rectangle SPW U075SXHT SPW U095SXHT SPW U125SXHT SPW U165SXHT SPW U185SXHT Duct US type 7 SPW US075XH SPW US095XH SPW US125XH SPW US165XH SPW US185XH Concealed Duct FUR type Floor Ceiling Slim
15. 0 023 Elm A 0 16 0 16 0 16 0 19 0 19 0 20 Heating A 0 17 0 17 0 18 0 20 0 20 0 20 Sirroco fan Fan motor Airflow rate H M L m min 9 7 5 6 10 8 5 6 5 Output kW 0 047 Power sound level H M L dB A 46 43 39 48 44 40 Pressure sound level H M L dB A 35 32 28 37 33 29 Height mm 285 Dimensions Width mm 825 Depth mm 217 Liquid Flare mm in 6 35 1 4 Piping connections Gas Flare mm in 12 7 1 2 Drain piping VP 13 Net weight kg 10 Data subject to change without notice Dimensions mm Refrigerant tubing gas tube 912 7 flared Refrigerant tubing liquid tube 6 35 flared Drain hose VP13 outer dia 18 Rear panel PL BACK Rear panel fixing holes 5 holes or 5 x 13 oval holes Piping amp coiling holes 265 WALL MOUNTED UNITS El WALL MOUNTED UNITS OPERATION en au Option Wired remote controller eWireless remote controller eSimplified remote controller Ll Cms 5 RCS TM80BG RCS SH1BG RCS BH80BG WL RCS KR1AGB Closed discharge port Elegant color and round shape design When operation is stopped the flap closes completely to adoption of horizontal stripes prevent entry of dust into the unit and to keep the The compact design matches the interior and installatio
16. efficiency 100 d 40 3 Power generation ic Ae i 3 w n m Generated electricity KW Increase in gas consumption due to power generation HHV Higher Heating Value standard 100kg lighter compared to K Series GHP Due to the light weight reduction of physical distribution costs is possible Furthermore it is an advantage when setting up on the roof GHP 2 Series Engine Power generator 1 00Kg lighter j A Power Converter Compressor GHP 1 Series 970kg Variable Refrigerant Flow products HP Cooling capacity kW 56 0 101 0 112 0 1270 Capacity Heating STD kW 63 0 103 0 113 0 126 0 143 0 capacity Low temp kW 67 0 109 5 120 0 134 0 142 0 Hot water Cooling mode kW 22 0 34 0 37 5 44 0 52 0 Power generator capacity at rating kW DC 2 5 Max 4 3 DC 2 5 Max 4 3 DC 2 5 Max 4 3 DC 5 0 Max 8 6 DC 2 5 Max 4 3 Electricity Power kW 05 2 20 270 20 270 Power kW 1 01 2 02 2 07 2 07 29b kW 44 0 38 3 68 5 75 6 88 0 104 9 Gas consumption H STD KW 48 7 43 0 76 8 84 8 97 4 101 0 H LOW kW 62 1 56 4 9919 109 4 24 2 1124 3 A Cooling 1 29 29 1 23 IRIS Air conditioning n COP Heating 1 34 1 43 Tel 1 30 1 27 1 38 AVE 1 34 1 42 1 30 1 30 1 25 1 26 Max Cooling 1 78 1 81 1 80 1 78 1 69 Size Height x Width x Depth 2 248 x 1 800 x 1 000 60 2
17. 28 1 35 5 Over 36 5 628 58 031 75 225 4 219 05 e Tubing size after branch In 2 2 5 6kW 212 7 29 52 15 88 212 7 29 52 ZT 16 0 615 88 69 52 015 88 212 7 99 52 Branch Kit table Under 8 9kW e e 9 0 16 0 16 1 28 0 e 35 6 45 0 Over 45 0 gt m WATER HEAT EXCHANGER INSTALLATION INSTRUCTION Installation instruction of GHP Water Heat Exchanger Thermometer Pressure Gauge Pump Strainer EG c eL 80 eee Flow Switch Refrigera nt eee ee t oc E ion Tank liquid tub Rescuers 2 xpansion lan Iquid tube Dd eee eee E eL AC AE CA 0 Maximum ANO allowable x EEUU EDDA m flow rate Communication cable 0090909090900 5 lt RRR 2 5 minimum dos p po UU Remote CUS ae controller 0 00 2 00 400 6 00 800 10 00 12 00 14 00 8 o 5 Cold hot water flow rate lt X 3 xl 170 To the buffer Tank gt lt Q 400 Vraximum Tk 7 amp 35 0 allowable L 30 0 flow rate Refrigerant gas tube 0 FS 2 standard wes OO Es oe ow rate From the buffer Tank lt W 8 400 minimum D gt NEY ater Outlet S 100 required 7 T n BEES IMEEM Water pump
18. 36 34 33 36 35 34 38 36 34 45 40 36 Height mm 200 lt 20 gt Dimensions Width mm 1 000 1 230 Depth mm 710 800 Liquid Flare mm 6 35 9 52 Piping connections Gas Flare mm 27 15 88 Drain piping VP 25 Net weight kg 211 lt 55 gt 221 lt 55 gt Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data The values in for external dimensions and net weight are the values for the optional ceiling panel The values in forair flow rate and operating sound are for use of the accessory cable Data subject to change without notice Dimensions mm Air intake grille Air outlet Refrigerant piping 9 18 6 35 flared liquid pipes 25 SEMI CONCEALED SLIM CASSETTE B 9 52 flared Refrigerant piping 9 18 12 7 flared gas pipes 25 15 88 flared Power supply entry Drain connection VP25 outer diameter 32 for descending ceiling Discharge duct connection port Wireless remote control receiver option Panel center X p 1000 X 20 1190 ceiling opening dimension 20 Fresh air intake 100 ceiling opening dimension Suspension bolt pitch Suspension mounting 4 12 x 30 slot
19. gt Q 3 Zone 4 mode Zone 4 central control Zone 4 remote control Example 5 All central control 1 1 Con 1 1 System controller remote controller ee ee ee eee ee ea Se Se 1 el lt All mode Example 1 All remote control ES E E Zone 1 mode c ples da control Zone 1 remote control Group control 1 I 1 iE Y us al vale QOO Zone 2 System controller Control mode example 3 Remote control for zone 2 Maga aaa Individual remote controller Control mode example 4 Central control for zone 3 Co SS 67 5 L e o D System controller System without a remote controller Control of a group without remote controller 0 i Control mode example 5 Remote control for zone 4 Dl trol mode example 1 61 lll intelligent controller SHA KT256EG Power supply O part Dimensions H 240 x W 280 x D 138 mm OAC 100 to 240 V 50 Hz 20 W separate power supply ORemote input voltage free contact All on off output voltage free contact All ON All alarm external power supply within DC 30 V Total wiring length O1 km for each system Only for embedding in the panel Limitation contents for prohibited operation Prohibition means limitation of the operation contents from the remote
20. ll Wired remote controller RCS TM80BG e Basic remote controller ON OFF OOperation mode changeover Cooling Heating Dry Auto Fan O Temperature setting Cooling Dry 18 30deg Heating 16 30 deg OAir volume adjustment HH H LL Auto OAir flow direction adjustment Time Function O24 hours real time clock ODay of the week indicator Weekly Program Function OA maximum of 6 action can be programmed for each day Outing Function OThis function can be prevent the room temperature from dropping or rising when the occupants are out for a long time Sleeping Function OThis function controls the room temperature for comfortable sleeping Dimensions H 120 x W120 x D16 mm Max 8 indoor units can be controlled from one remote controller Remote control by main remote controller and sub controller is possible 2 remote controller main remote controller and sub controller can be installed for one indoor unit ll Wireless remote controller e Ventilation independent operation is possible OWhen commercial ventilation fans or heat exchange B B ventilation fans have been installed they can be a operated with this remote control interlocked operation i with the indoor unit or independent ventilation ON OFF m a 1 i i nem T a Easy installation for the 4 way cassette type simply by replacing the corner part DTE 24 hours timer function XM t
21. 0 070 0 100 0 109 0 117 Cooling A 0 45 0 45 0 45 0 44 0 45 0 45 0 44 0 45 0 45 0 45 0 45 0 45 0 64 0 65 0 66 Heating A 0 29 0 29 0 30 0 28 0 29 0 30 0 28 0 29 0 30 0 29 0 29 0 30 0 46 0 48 0 49 Type Sirocco fan 1 Sirocco fan 2 Fan motor Airflow rate H M L m min 8 7 6 9 8 7 9 6 8 6 7 6 11 9 8 19 16 14 Output kW 0 03 0 05 Power sound level H M L dB A 40 38 35 44 40 37 45 42 39 46 44 40 49 46 44 Pressure sound level H M L dB A 30 27 24 33 29 26 34 31 28 35 33 29 38 35 33 Height mm SON Dimensions Width mm 840 lt 1060 gt 1140 lt 1360 gt Depth mm 600 lt 680 gt Liquid Flare mm 6 35 9 52 Piping connections Gas Flare mm 27 15 88 Drain piping VP 25 Net weight kg 23 30 lt 9 gt Rated conditions The values in lt gt for external dimensions and net weight are the values for the optional ceiling panel Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Data subject to change without notice Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Dimensions mm Air intake 7 18 type 25 type Air outlet 940 1 140 Ceiling opening dimensions 480 630 1 020 1 320 Refrigerant piping liquid pipes 1 060 1 360 Refrigerant piping gas pipes Suspension fitting notch 12 mm SEMI CONCEALED CASSETTE 2 WAY AIR DISCHARGE Ceiling opening dimensions 1 020x
22. 26 0 25 Type Centrifugal fan Fan motor Airflow rate H M L m min 8 7 06 9 8 7 10 7 8 5 7 5 12 5 10 5 9 Output kW 0 020 Power sound level H M L dB A 46 43 41 49 46 42 bay 467 45 58 54 50 Operating sound H M L dB A 30 27 25 32 29 26 36 32 28 41 37 33 Height mm 283 Dimensions Width mm 575 lt 625 gt Depth mm 575 lt 625 gt Liquid Flare mm 6 35 1 4 Piping connections Gas Flare mm 1277202 Drain piping VP 20 Net weight kg 16 2 4 Rated conditions The values in lt gt for external dimensions and net weight are the values for the optional ceiling panel Data subject to change without notice Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Discharge outlet Ceiling opening dimensions Refrigerant tubing liquid tube 7 18 type 26 35 flared 534 Suspension bolt pitch Refrigerant tubing gas tube 7 18 type 012 7 flared Power supply port Drain tube connection port VP20 outer dia 226 CD Suspension bolt hole 4 12 x 30 hole Fresh air intake duct connection port 2100 Dimensions mm 534 Suspension bolt pitch 600 Ceiling opening dimensions
23. F5 independent of the mode Further comfort improvement The wide air discharge opening widens the air flow to the left and the right so that a comfortable temperature is obtained in the entire room The unpleasant feeling caused when the air flow directly hits the human body is prevented by the Draft prevention position which changes the swing width so that the degree of comfort is increased Correspondence to ceiling heights up to 4m Indoor units specifications T125XH T165XH T185XH T255XH T365XH T485XH Power source 220 230 240V 1 phase 50 60Hz Salina se etes kW 3 6 45 5 6 7 3 10 6 14 0 BTU h 12 000 15 000 19 000 25 000 36 000 47 800 e kW 4 2 5 0 6 3 8 0 11 4 16 0 BTU h 14 000 17 000 21 000 27 000 39 000 54 600 Cooling kW 0 028 0 029 0 029 0 031 0 032 0 032 0 043 0 043 0 044 0 073 0 074 0 075 0 085 0 086 0 088 Heating kW 0 028 0 028 0 029 0 031 0 031 0 032 0 042 0 042 0 043 0 072 0 073 0 074 0 084 0 085 0 086 Swaine AU aS 2521018 0 26 0 24 0 23 0 28 0 26 0 24 0 38 0 35 0 33 0 62 0 57 0 53 0 69 0 63 0 60 Heating A 0 26 0 24 0 23 0 28 0 26 0 25 0 38 0 35 0 34 0 62 0 57 0 55 0 69 0 63 0 62 Type Sirocco fan 2 Sirocco fan 3 Sirocco fan 4 Fan motor Airflow rate H M L m min 12 10 9 13 11 9 18 5 15 14 27 5 23 20 30 26 22 Output kW 0 03 0 04 0 08 Power sound level H M L dB A 46 43 41 47 44 41 49 47 4
24. GESSISSE kW 22 2 8 3 6 45 56 BTU h 7 500 9 600 12 000 15 000 19 000 Heating capacity kW 25 22 4 2 50 6 3 BTU h 8 500 11 000 14 000 17 000 21 000 FOROR E Cooling kW 0 036 0 036 0 036 0 040 0 040 0 040 0 042 0 042 0 042 0 049 0 049 0 049 0 064 0 064 0 064 Heating kW 0 026 0 026 0 026 0 030 0 030 0 030 0 032 0 032 0 032 0103970099 0039 0 054 0 054 0 054 Cooling A 0 26 0 26 0 26 0 30 0 30 0 30 Ors U20 O 0 48 0 48 0 48 Heating A 0237 023 023 T 21 0 28 0 28 0 28 0 34 0 34 0 34 0 45 0 45 0 45 Type Sirocco fan posed Airflow rate H M L m min B 7 6 ove 5 09 er AG Output kW 0 05 External static pressure Pa 10 30 15 30 15 40 Power sound level H M L dB A 43 42 40 45 44 42 47 45 43 49 47 45 52 50 48 Pressure sound level H M L dB A 28 27 25 30 29 27 32 30 28 34 32 30 35 33 31 Height mm 200 Dimensions Width mm 150 Depth mm 640 Liquid Flare mm 6 35 1 4 Piping connections Gas Flare mm 12 7 1 2 Drain piping VP 20 Net weight kg 19 Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Inspection access PA Data subject to change without notice Dimensions mm Refrigerant tubing joint narrow tube Refrigerant tubing Joint wide tube Upper and bot
25. How GHP works from the inside of the room by liquefaction of refrigeran Compressor Gas engine Absorption of heat from the room by liquefaction of refrigerant Absorption of heat from the a ine waste heat 1 outside air by evaporation of refrigerant Compressor Gas engine Discharge of heat generated by condensation of refrigerant The advantages of GHP Speedy and powerful Advantage High energy and powerful High energy high power only possible for fuel gas power Quick start up Fast start up is achieved by collection and reusing the waste heat produced by the combustion No need for a defrosting operation There is no interruption of heating operation so unpleasant cold air in the room is avoided comparison of the start up times for heating operation comparison of heating capacity Room temperature Heating capacity 96 25 px Gas heat pump Covers up to 20 degrees with standard specifications Gas heat pump 5 Electric heat pump Electric heat pump 20 15 10 5 0 5 10 Elapsed time The case of same load Outside air temperature C Always comfortable Advantage The engine speed is computer controlled and is determined by N 2 the room temperature The room temperature is therefore kept comfortable at all times A gas engine is used to drive the compressor The speed of the engine is controlled efficiently by a microcomputer according
26. ON OFF operation mode fan speed air flow direction only when used without a remote controller operation monitoring alarm monitoring ventilation remote controller local operation prohibition etc Individual All operations are possible also from the remote controller However the contents will be changed to the contents of the controller operated last The remote controller cannot be used for ON OFF Central 1 other operations are possible from the remote controller Dimensions 160xW 160x D21 69 embedding dimension mm Central 2 The remote controller cannot be used for ON OFF mode change and entra 2 temperature setting All other operations are possible from the remote controller Power supply OAC 220 to 240 V O part O Remote input effective voltage DC 24 V Central 3 The remote controller cannot be used for mode change or temperature setting All OFF change All other operations are possible from the remote controller Remote output voltage free contact All OFF Central 4 he remote controller cannot be used for operation mode change external power supply within DC 30 V All other operations are possible from the remote controller Total wiring length 1 km Joint use with a remote controller an intelligent controller a schedule timer etc is possible The maximum number of connectable system controllers is 10 including other cent
27. S medium pressure liquid n 120m piping allows effective system designs Suction pipe low temperature Allowable piping length is a max of 120m actual length of 145m This allows flexible installation and low pressure gas pipe system designs Up to 28 indoor units are capable of simultaneous heating cooling operation Discharge pipe high temperature high pressure gas pipe Additional parts Solenoid valve kit Solenoid valve controller eATK RZP56BGWB eACC 3WAY AGB For 74 to 254 indoor unit eATK RZP160BGWB For 364 to 604 indoor unit esses Distribution joint kits e APR RZP224BGB 16 0 kW or less e APR RZP680BGB 28 0 kW or less For conference rooms and other locations where low noise is required e APR RZP1350BGB pay attention to the installation location and install on a corridor etc More than 35 kW The industry s smallest SVK box 166 x 147 x 217mm Water Heat Exchanger Water Heat Exchanger available up to 56 kW for Cooling capacity GHP Chiller Water Heat Exchanger Water Piping M Refrigerant Piping Outdoor unit X T E gt El E Fan Coil Unit b x We cU Duct cu gt 7 cu Air Handling Unit The GHP WHE can provide water at a wide range of temperatures suitable for a wide variety of commercial applications from comfort air conditioning to food processing or the replacement of boilers and other systems e
28. Water Inlet T 00 To the To the To the 0 00 5 00 10 00 15 00 20 00 drain pipe drain pipe drain pipe Cold hot water flow rate ms h Water piping construction Warning e Only use water as the heat medium for the hot and cold water and the chilled water Otherwise this could result in fires or explosions Caution e Use water that complies with water standards for hot and cold water and for cooling water Poor quality water can cause breakdown or water leaks e Dispose of brine and cleaning fluid in accordance with the applicable regulations If these items are illegally disposed not only will this result in legal matters but it will also have bad effect on the environment and health 7 Adjust the water pressure so that the pressure in the water heat exchanger is less than 0 69N mm 1 Water pipes can be connected to either the front or the rear of the water heat exchanger unit When shipped from the factory rubber stoppers are fitted to the openings Openings that are not being used should be closed with the rubber stopper 8 Install an expansion tank within the water pipe system 2 Connect the hot and cold water circulation pump to the inlet pipe side of the water heat exchanger 3 Make the opening of the water pipe larger than the opening of the connector 50A and use as few bends as possible in order to reduce the pipe resistance as much as possible Also use unions or flanges near the unit so that the unit
29. Weight with grille panel Kg 21 23 28 22 36 FW K011EH5 FW K021EH5 FW K031EH5 FW K041EH5 Main power supply V Ph Hz 230 1 N 50 Total cooling capacity Max Med Min kW 1 24 0 80 1 67 0 96 2 90 1 57 3 50 2 95 Sensible cooling capacity Max Med Min kW 0 94 0 58 1 30 0 74 2 20 1 20 2 70 1 80 Heating capacity Max Med Min kW lea 2 38 1 49 3 90 2 45 5 40 3 60 Air flow Max Med Min m h 220 150 210 180 585 360 120 410 Absorbed power Max Med Min W 24 19 20 16 75157 06 57 Water flow Max Med Min l h 215 135 290 165 500 274 615 415 Sound power level Lw Max Med Min 44 3 45 35 50 46 55 48 Sound pressure level Lp Max Med Min 35 28 36 26 41 37 46 39 Water connections inch 1 2 female Dimensions H W D mm 270x805x177 270x805x177 285x995x206 285x995x206 Weight Kg 8 0 8 0 12 12 FW FT021EH5 e FW FT031EH5 e FW FT041EH5 Performance FW FT021EH5 FW FTO31EHS FW FTOA1EHS Main power supply V Ph Hz 230 1 N 50 Total cooling capacity Max Med Min kW 2 10 1 20 0 90 3 19 2 10 0 90 3 90 3 10 1 65 Sensible cooling capacity Max Med Min kW 1 50 1 00 0 70 2 47 1 50 0 70 3 00 2 50 1 25 Heating capacity Max Med Min kW 3 10 2 00 1 60 4 07 3 00 1 60 5 00 4 40 2 10 Air flow Max Med Min m h 430 300 210 520 430 210 675 570 327 Absorbed power Max Med Min W 40 30 26 46 37 26 70 53 35 Water flow Max Med Min l h 360 206 160 550 360 160 670 530 285 Sound power level Lw Max Med Min dB A 48 43 35 50 45 35 54 51 40 Sound pressure
30. atmosphere is recovered via the heat exchanger and effectively used as hot water so the GHP Chiller acts as a sub system that alleviates the load on the client s main hot water system and therefore offers free hot water Capacity at cooling standard point Outlet temp 75 C LI I Outdoor unit SGP EW120M2G2W kW 12 0 SGP EW150M2G2W 16 0 G H P SGP EW190M2G2W 20 0 SANYO SGP EGW190M2G2W 22 0 SGP EW240M2G2W 25 0 ROE Hot water piping allowable pressure MPa 0 7 I Hot water circulation rate m h 3 9 Hot water tube size Rp 3 4 9 4 Electric connection 240AC 3A t Dg EN Manometer Expansion tank Electric Design Boiler Ce Cold water Pump Valve e All the items illustrated in this draw exception outdoor unit are not Sanyo s supply e During start up set temperature value of the water in the outdoor unit s parameter Magnetic Relay 17 INDOOR UNITS FOR DIRECT EXPANSION SYSTEM Wide choice of models depending on the indoor requirements Model size 7 9 12 16 18 22 KW Cooling 2 2 2 8 3 6 4 5 5 6 6 4 Heating 25 3 2 42 5 0 6 3 7 0 Capacity BTU h Cooling 7 500 9 600 12 000 15 000 19 000 22 000 Heating 8 500 11 000 14 000 17 000 21 000 24 000 p SPW XM075XH SPW XM095XH SPW XM125XH SPW XM165XH SPW XM185XH Cassette 4 Way
31. eSeri Para I O unit for each indoor unit SHA KC16KAGB ACC SP16TAG 4 90 5 hole ACC SP1AGB 75 e 1 420 7 5 50 50 520 18 231 0 hole opposite side included 15 o id 10 ow eLonWorks interface eSeri Para 1 0 unit for outdoor unit fe SHA LN16UGB ACC XSP4U1GB z 500 Qa 270 Co Lo 255 AE 0 5 LE lt i E Of 5 A 5 g LLI cc Detail of the potbellied hole e 64 S nyo otal j ntelligent IVI NL ystem SANYO STAIMS STAIMS Basic software TECS 5000 Up to 1024 indoor units can be controlled by one PC eStandard remote control for all indoor units eMany timer schedule programs can be set on the calender eDetailed information display for alarms eCSV file output with alarm history operating status eAutomatic data backup to HDD With 4 upgrade packages the basic software can be upgraded to sult individual requirements STAIMS optional software lt STAIMS optional software TECS 5000A for Load distribution TECS 5000G for Object layout display Load distribution calculation for each tenant Whole system can be controlled visually E m e Air conditioner load distribution ratio is z e Operating status monitor is available on calculated for each unit tenant with 1 3 the layout display used energy consumption data kWh ye e Object s la
32. electricity in using the power generated by the air conditioning IU 22 Lights computers etc amp lt Generator l Power Converter Power Inverter Gas Engine 8 300V DC 220 240V 50Hz T v Cooling Heating M Dp Max 4 3kW Max 4 0kW ain power P EM 4 supply med Compressor Generation by air conditioning Integrated generator 4 kW No destruction of ozone layer HFC type R410 refrigerant 40 Generation efficiency realised Progress in energy use efficiency Reducing C02 emission by up to 30 by improving energy efficiency By harnessing excess energy created during air conditioning electrical power generation efficiency of over 40 is achieved during cooling and heating value standard Due to energy efficiency when compared to using commercial electricity CO2 emissions can be reduced by 30 1 Compared to our GHP standard multi for building use Calculated according to the unit CO2 emission standard for thermal power generation House in demand Power generation Primary energy p mercial 100 25 p efficiency electricity 0 loss during Loss during 36 A fuel power generator wa DONGEUSRISITISSIOR x5 2 Power generation efficiency Heat efficiency of 36 9 at the house in demand according to the law of energy conservation House in demand Power generation with engines using excess i Power generation G power ous
33. level Lp Max Med Min dB A 40 35 21 42 31 21 46 43 32 Water connections Dimensions amp Weic Dimensions H W D Weight 1 2 female 680x900x190 28 NOMINAL CONDITIONS Cooling Heating Sound pressure level Entering Air Temperature 27 C db 19 C wb 2020 At 2m distance in closed environment Entering Water Temperature IB 50 C at same water flow as for cooling 100m volume with 0 5 sec reverberation time Leaving Water Temperature A236 60 maximum water entering temperature 55 Very wide and complete line up cen trifugal or cross flow fan 2 pipe or 4 pipe design e Decorative cabinet can easy match with any kind of rooms e Cleanable air filter included FAN COIL UNIT e Easy to install and very simple maintenance Large choice of accessories either separately supplied or factory Electronic controllers available for mounted unit mounting and remote installation ensure precise control of the room temperature HM S VMT HMT VHT 151 251 351 Main power supply V Ph Hz 230 1 N 50 CROSS FLOW Total cooling capacity Max Med Min kW 1 40 1 20 1 04 2 40 2 08 1 70 3 40 2 80 2 30 Sensible cooling capacity Max Med Min kW 1 17 0 92 0 78 2 02 1 62 1 31 2 87 2 30 1 89 Heating capacity standard coi Max Med Min kW 2 08 1 66 1 46 3 10 2 70 2 30 4 30 3 60 2 90 Heating capacity add 1 row Max Med Min KW 1765 1 35 120
34. lift drain pump and correspondence to Up to 850 mm long horizontal piping is possible 21 Indoor units specifications SPW X075XH X095XH X125XH X165XH X185XH X255XH X365XH X485XH X605XH Power source 220 230 240V 1 phase 50 60 Hz o 25 28 3 6 4 5 5 6 10 6 140 16 0 7 500 9 600 12000 15000 19000 25000 36000 47800 54600 25 32 42 5 0 6 3 8 0 11 4 16 0 18 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 39 000 54 600 61 400 Cooling kW 0 035 0 035 0 036 0 039 0 040 0 041 0 042 0 043 0 044 0 052 0 052 0 053 0 082 0 083 0 083 0 111 0 112 0 113 0 117 0 119 0 122 Heating kW 0 027 0 027 0 028 0 030 0 031 0 032 0 032 0 033 0 034 0 042 0 043 0 043 0 074 0 076 0 077 0 103 0 103 0 104 0 108 0 108 0 111 ee Cooling JA 0 27 0 27 0 26 0 31 0 30 0 30 0 34 0 33 0 32 0 43 0 42 0 41 0 67 0 63 0 60 0 91 0 88 0 84 0 97 0 92 0 92 Heating A 0 23 0 23 0 22 0 26 0 25 0 25 0 29 0 28 0 28 0 38 0 36 0 35 0 64 0 63 0 62 0 89 0 88 0 86 0 96 0 95 0 93 Type Turbo fan 1 Fan motor Airflow rate H M L m min 15 5 14 13 16 14 13 20 16 14 zo 1 33 25 22 922 272 Output kW 0 05 0 09 Power sound level H M L dB A 42 40 38 45 42 39 50 47 44 53 49 45 55 51 47 Pressure sound level H M L dB A 31 29 27 34 31 28 39 36 33 42 38 34 44 40 36
35. to the room temperature so that there is no temperature loss Gas heat pump air conditioner Electric air conditioner At the time of cooling Room temperature Energy loss temperature temperature High speed Operation Operation condition condition engine Sow Sheed motor OFF ON OFF ON OFF ON with speed efficiently controlled by microcomputer Large electric load at the time of start Low power consum pti on Electricity consumption Advantage Reduce power consumption significantly c As gas is used as a heat source electricity is only needed Gas heat pump Electric heat pump to power auxillary equipment such as fans etc Electricity consumption depends Comfortable air conditioning even during power capacity shortage on the conditions of use The power consumption at around 8 horsepower is only 0 70 kw 50Hz during cooling Reduction of power receiving equipment GHP LINE UP G PO WER Reduction of running costs Highly efficient power generation is possible by using excess energy from the engine while air conditioning Air Power Hot water This is a revolutionary model The generated electricity can be used not only 9 89 60 for GHP operation but also for the external devices oe la The Electrical Power Consumption required for air conditioning is practically zero It contributes to the reduction of contract power Power generation effect is over 4
36. 00 11 000 14 000 17 000 21 000 0 087 0 087 0 087 0 087 0 087 0 087 0 41 0 41 0 41 0 41 0 41 0 41 Centrifugal fan 1710 6 3 1225 5 5 6 0 06 0 06 54 51 48 55 51 48 43 40 37 44 40 37 296 570 STOP 575 lt 720 gt 6 35 1 4 VP 18 gJ 16 5 lt 2 5 gt P257 Rated conditions Data subject to change without notice Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Dimensions mm Suspension j Suspension bracket bracket L ll T Fresh air intake side Suspension bracket Electrical component box side Suspension bolt 2 f T 4 Refrigerant Nuts and tubing side Washers D 18mm 2 9 Fresh air intake port Refrigerant tubing side Condensate drain piping Refrigerant tubing joint o narrow tube 270 Refrigerant tubing joint 90 wide tube SEMI CONCEALED CASSETTE 4 WAY AIR DISCHARGE Option OPERATION Y E ZW e Wired remote controller e Wireless remote controller eSimplified
37. 096 which is better than thermal power generation During cooling and Heating l For lightings laptops Substation OA equipment etc Electrical Equipment LEO 7772 W MLLTI For Indoor units etc Generated electrical power Cooling Heating L Commercial electrical power W MULTI The Industry s largest horsepower GHP Achievement of industry s largest horsepower around 50HP by combining 2 outdoor units The Appropriate Load Divider Function ensures energy saving and thus a reduction of running costs Non stop operation even during maintenance Long lifetime ECOG W MULTI SWAY MULTI Simultaneous cooling and heating P operation SE Within the same refrigerant system it is possible for cooling heating to be run at the same time This is optimal for use in buildings that contains rooms with large temperature Ga differences or rooms which require cooling throughout the year ECOG 3 WAY MULTI PX ME Example Hotroom Increased efficiency and even lighter than before Now GHP has even greater reliability than before Excellent performance on partial load When it is partial load the average COP for warm and cold The 190 models achieved 1 85 It is more leading as of December 2007 Partial COP Partial interim capacity Partial gas consumption K2 series 2 series 190 model Lon
38. 2 60 2 25 1 95 3 50 3 00 2 45 Air flow Max Med Min m h 300 240 190 450 360 290 600 480 380 Absorbed power Max Med Min W 40 30 27 50 45 37 65 50 42 Water flow cooling Max Med Min l h 240 210 180 240 210 180 585 485 400 Water pressure drop heating Max Med Min kPa 4 0 3 2 2 4 14 7 11 8 8 5 13 2 10 0 7 0 Water flow heating Max Med Min 145 120 105 225 195 170 300 260 210 Water pressure drop heating Max Med Min kPa SIA 8 9 6 9 5 4 Sound power level Lw Max Med Min dB A 48 40 34 41 42 36 48 43 39 Sound pressure level Lp Max Med Min dB A 39 31 25 38 33 21 39 34 30 Dimensions H W D S VMT mm 530x775x225 530x990x225 530x1205x225 Dimensions H W D S HMT mm 225x775x530 225x990x530 225x1205x530 Dimensions H W D S VHT mm 530x567x218 530x782x218 530x1007x218 Weight S VMT kg 18 26 20 Weight S HMT kg 18 26 29 Weight S VHT kg 17 29 28 S VMC HMC VHC 151 251 351 401 501 601 701 151 4 251 4 351 4 401 4 501 4 601 4 701 4 Main power supply V Ph Hz 230 1 N 50 Total cooling capacity Max Med Min kW 1 50 1 30 1 10 2 50 2 15 1 80 3 50 2 90 2 47 4 00 3 44 2 90 4 80 4 15 3 60 5 95 5 08 4 30 6 60 5 50 4 60 Sensible cooling capacity kW 1 25 1 00 0 83 2 10 1 68 1 39 2 95 2 35 1 95 3 95 2 69 2 21 4 05 3 24 2 67 5 00 4 00 3 30 5 50 4 40 3 64 Heating capacity standard coil Max Med Min kW 2 06 1 70 1 40 3 30 2 70 2 30 4 45 3 70 3 00 5 20 4 35 3 65 6 60 5 50 4 70 8 00 6 70 5 50 8 80 7 30 6 00 Heating capacity add 1 row coil M
39. 248 x 1 800 100 Min distance 4 1 800 x 1 000 60 Weight kg 875 1 660 1 685 1 740 1 720 Starter amperes A 30 30 Gas 028 58 931 75 031 75 038 1 038 1 Liquid 15 88 9 19 05 Pipe Balance g 9 52 2 9 52 Fuel gas R3 4 Bolt thread R3 4 Bolt thread 2 25 Rubber hose Exhaust drain port o 25 Rubber hose Operation sound dB 58 61 61 61 63 Indoor Outdoor capacity ratio 50 13096 50 13096 Number of connection indoor 32 48 In case of not generator working Specifications subject to change without notice 1 Low temp condition Outdoor temperature 2 C G POWER W MULTI The inustry s largest horsepower of around 50HP is achieved by combining 2 outdoor units As of March 2007 ECO W Multi for Heat Pump Flexibility to design the sytsem according to the surrounding space Applications Freedom in designing the system Connectable indoor unit models are W Multi is a system which even allows the 22 280 and up to 48 units are able to be connected connection of 2 outdoor units SANYO s W Multi uses the indoor outdoor multi method Number of indoor units that can be connected Up to 36 units per 1 outdoor unit Up to 48 units There exist some un connectable indoor units Easy to add additional units in the future Load can easily be increased in the future by the addition of indoor and outdoor units without having to plumb pipe shafts When specifying plumbing please choo
40. 3 Depth mm 1000 1120 1220 Liquid Flare mm 6 35 1 4 Piping connections Gas Flare mm 12 7 1 2 Drain piping VP 25 Connection Duct Diameter mm 250 300 Net weight kg 134 153 168 Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Service space The values in forthe external static pressure and operating sound are for use of booster cable 1 Heat recovery capacity by heat exchanger Data subject to change without notice Suspension bolt pitch m Dimensions mm Refrigerant piping liquid pipes Refrigerant piping gas pipes Suspension bolt pitch 4 15 x 52 holes M12 bolts Electric equipment box Communication line inlet 100 or more 0 Power supply inlet Drain VP25A male thread amp Humidifier Option Total heat exchanger TOTAL HEAT EXCHANGER WITH DX COIL n Long life Filter Highly efficient filter Option Air filter Mogi A 1 BDB EG I _ GUO55 1000 1785 890 1835 426 194 205 425 290 175 INDOOR UNIT FOR HYDRONIC APPLICATION WATER TERMINAL UNIT e 3 way valve kit features precise temperature co
41. 4 52 49 46 54 51 48 Pressure sound level H M L dB A 35 32 30 36 33 30 38 36 33 41 38 35 43 40 37 Height mm 210 Dimensions Width mm 910 1180 1595 Depth mm 680 Liquid Flare mm 6 35 9 52 Piping connections Gas Flare mm 12 7 15 88 Drain piping VP 20 Net weight kg 21 25 33 Rated conditions Cooling Indoor air temperature 27 DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Data subject to change without notice Dimensional data Dimensions mm Drain port VP20 inner 226 hose accessory Drain for left piping Upper piping outlet port knock out hole Right piping outlet port knock out hole Power supply entry port knock out hole 240 Wireless remote control receiver mounting part 25 B suspension bolt pitch Refrigerant piping gas pipes Refrigerant piping Suspension bolt pitch 015 88 015 88 Suspension bolt pitch CEILING MOUNTED UNITS SSIS Air outlet A 4 250 or more 250 or more Service space Service space f 500 or more Air intake FLOOR CEILING MOUNTED UNITS Option Three speed centrifugal fan Low operating sound Anti mold a
42. 640 1 320x640 Drain connection VP25 outer diameter 32 Inlet for option cord between power supply and unit Y Inspection lid 450 E Refrigerant piping 96 35 39 52 liquid pipes 0 Drain pan drain pump inspection lid Z Drain pump inspection lid ss Refrigerant piping 12 7 915 88 gas pipes Round flange field supply mounting part fresh air inlet 125 z 2 Duct connection port only on the right side 2x 1 pc 2x 2 pc Discharge duct field supply mounting part Ceiling panel and ceiling installation possible only on the right side opening center Wireless remote controller option signal receiver installation part 26 OPERATION 7 es a Fv 2 PFA Option e Wired remote controller e Wireless remote controller eSimplified remote controller ePanel E d p m RCS TRP80BG WL C c Ws N mat RCS TM80BG am RCS BH80BG WL RCS KR1AGB PNR AD124GHB E Compact Size in the top class of the ind
43. 6B DR484GXH56B DR764GXH56B DR964GXH56B Ed OPERATION T DRY SPW T255XH SPW T365XH SPW T485XH V Ln DRY au e OPERATION w OPERATION RY 0 SPW OPERATION 7 I 1 KR254GXH56B EA 2 SPW T 7 9 2546 56 EA SPW FT 7 v 7 FR254GXH56B F3 ns Oo Rating Conditions Cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB 24 C WB Heating Indoor 20 C DB Outdoor 7 C DB 6 C WB 18 SEMI CONCEALED 4 WAY AIR DISCHARGE Option e Wired remote controller e Wireless remote controller eSimplified remote controller RCS XIM18BG WL A p m RCS TM80BG RCS BH80BG WL RCS KR1AGB New turbo fans and heat exchanger fins with new shapes are adopted and the operating sound could be dramatically reduced by max i dB A 35 0 ___ 25 31 31 5 5 26 Seis Sseres gg Series Wide reduction of the power consumption by adoption of newly developed DC fan motors with variable speed new heat exchangers etc kW 0 10 0 05 HH series 4 ven 4 series 2 Makal 5 series XDRiyp 5 series XDR type 5 series type 7 9 ePanel PNR XM185
44. 8 W Achieved a total capacity of 1 million HP in Japan type Concealed Floor Standing Units 2001 W Achieved a total of 100 000 Systems in Japan ape na World First li Selling GHP W multi system in Japan GUy e 2003 W Achieved a total capacity of 2 million HP in Japan Selling GHP R407C J series in Europe 2004 World First W Selling GHP with R410A system in Japan 2006 ll Achieved a total of 1 000 Systems in Europe 2008 W Selling GHP W Multi and G Power in Europe lll Achieved a total of 2 000 Systems in Europe Convenient system control e e 9 9 09 0e 09 09 09 09 09 09 09 O 09 9 O 09 9 09 Ol 09 09 Ol Ol Ol 09 0 09 06 O0 06 09 e e o o0 0 0G O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O oO How GHP works If you are short of electrical power SANYO gas heat pumps are the perfect solution Runs on gas and just needs single phase supply Enables the building s electrical power supply to be used for other critical electrical demands Reduces capital cost to upgrade power substations to run heating and cooling systems Reduces power loadings within a building especially during peak periods Electricity supply freed up for other uses such as IT servers commercial refrigeration manufacturing lighting etc High performance surprisingly low operating cost by using gas fuel
45. AC GHP control network From the host connected to LonWorks basic settings and status monitoring is possible for up to 16 groups of A C units FUNCTIONS A C unit settings from the LonWorks communicator Settings for each group of indoor units Settings for all units Emergency stop Option 1 settings A C unit status notifications made to the LonWorks communicator Transmission intervals settings Configuration properties E Minimum time secured for transmission Select two of the following remote controller prohibit fan speed setting air direction setting filter sign reset Indoor outdoor uni control line System Controller LonWorks Center Control communication line Device Remote sensor E ON OFF controller SHA KC16KAGB e ART K45AGB m Dimensions H 121 x W 122 xD14 52 embedding dimension mm O AC 220 to 240 V ORemote input effective voltage within DC 240V All ON OFF O Remote output allowable voltage within DC 30V All ON All alarm Power supply O part his is a remote sensor which can be used with 4 series indoor unit Please use it to detect the room temperature when no 16 groups of indoor units can be controlled Collective control and individual group unit control can also be performed remote controller sensor or body sensor is used Correspondence to a system wit
46. CONCEALED DUCT Option E LA e Wired remote controller eWireless remote controller RCS TM80BG RCS BH80BG WL eSimplified remote controller RCS KR1AGB Realized comfortable space by dispersed arrangement of discharge ports The static pressure outside the unit can be increased By using the booster cable the static pressure outside the unit can be increased Pa e _ With booster cable use E Drain pump with increased adoption of a high lift drain Up to 300 mm pump the drain piping rise ae height could be increased to 785 Up to 500 mm Easy maintenance by external installation of the mm from the lower surface of the body electric equipment box Body electric equipment box 31 An inspection port 450 mm x 450 mm or more is required at the lower side of the indoor unit body Canvas Duct field supply Flange Canvas duct Inspection port 450 x 450 mm or more Inspection port 450 x 450 mm or more Distributor field supply Inspection port 450 x 450 mm or more Unified body height of approx 310 mm for all models Even models with different capacities can be installed smoothly in the ceiling Indoor units specifications SPW U075XH U095XH U125XH U165XH U185XH U255XH U365XH U485XH U605XH
47. Concealed Duct SPW FUR74EXH56B SPW FUR94EXH56B SPW FUR124EXH56B SPW FUR164EXH56B SPW FUR184EXH56B SPW FUR224EXH56B UMR type Concealed Duct SPW UMR74EXH56B SPW UMR94EXH56B SPW UMR124EXH56B SPW UMR164EXH56B SPW UMR184EXH56B SPW UMR224EXH56B DR type Concealed Duct High Static Pressure 25 48 type 76 96 type type Ceiling Mounted Units SPW T125XH SPW T165XH SPW T185XH FTR type Floor Ceiling Mounted Units SPW FTR74EXH56B SPW FTR94EXH56B SPW FTR124EXH56B SPW FTR164EXH56B SPW FTR184EXH56B SPW FTR224EXH56B i Wall Mounted K type m Units SPW K075XH SPW K095XH SPW K125XH KR type Wall Mounted Units 4 i SPW KR74GXH56B SPW KR94GXH56B SPW KR124GXH56B SPW KR164GXH56B SPW KR184GXH56B FIVIR type Concealed Floor Standing Units SPW FMR74GXH56B SPW FMR94GXH56B SPW FMR124GXH56B SPW FMR164GXH56B SPW FMR184GXH56B FR type Floor Standing Units J SPW FR74GXH56B SPW FR94GXH56B SPW FR124GXH56B SPW FR164GXH56B SPW FR184GXH56B GU type Total Heat Exchanger with DX coil SPW GU055XH SPW GU075XH SPW GU105XH OPERATION MA wider operation 4 ll Comfortable auto flap Self diagnosing function Automatic restart Er Automatic fan operation Mild Dr
48. Drain piping VP 20 Net weight kg 29 39 Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 DB 6 C WB Dimensional data Concealed Floor Standing type 4 x 912 holes for floor fixing Indoor unit A B 7 12 type 904 672 665 500 86 16 type type 2b type 18 10071002 980 900 51 Air filter Discharge duct connection flange Refrigerant connection outlet liquid pipes Refrigerant connection outlet gas pipes Drain filter 46 166 C nner dimension F E hole pitch 100 F im Drain pan Level adjustment bolt Drain outlet VP20 with vinyl hose Floor Standing type Data subject to change without notice 4x 212 holes for floor fixing Power supply outlet Indoor unit 3 Air filter 1912 type pipes pipes Refrigerant piping liquid pipes 16 type Level adjustment bolt 26 35 1212 7 Refrigerant piping gas pipes Refrigerant piping connection port bottom or rear Drain outlet VP20 with vinyl hose 29 52 1015 88 Operation switch remote controller RCS SH80AG mounting part Electric equipment bo
49. Flare mm 9 52 Piping connections Gas Flare 15 88 19 05 DD 277 Drain piping VP 25 Net weight kg 47 50 54 110 120 Data subject to change without notice Dimensions mm Refrigerant piping liquid pipes Refrigerant piping gas pipes Power supply inlet Drain 25A or VP25 Duct connection for suction Duct connection for discharge 76 96 type 800 or more service space 2 View in direction of arrow X Ix 1310 1070 28 0 4 33 5 holes entire circumference 10x100 pitch 1000 if 435 60 320 iq 1100 or more service space Suspension bolt pitch _9x 100 pitch 900 964 Le port 6007 SL 1200 Suspension bolt pitch 26035 holes 4 37 x 12 holes for suspension bolts Refrigerant piping liquid pipes 29 52 Refrigerant piping gas pipes 76 type 219 05 96 type 222 22 Power supply outlet 025 grommet rubber Power supply outlet spare 030 knock out Drain port 25A male thread Duct connection for suction Duct connection for discharge CONCEALED DUCT HIGH STATIC PRESSURE 43 Option
50. Height mm 256 35 319 35 Dimensions Width mm 840 950 Depth mm 840 950 Liquid Flare mm 6 35 9 52 Piping connections Gas Flare 127 15 88 Drain piping VP 25 Net weight kg 21 A45 22 lt 4 5 gt 26 lt 4 5 gt Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB The values in lt gt for external dimensions and net weight are the values for the optional ceiling panel Data subject to change without notice Dimensional data Dimensions mm 860to 910 pe ceiling opening dimension a Air intake grill Air outlet Refrigerant piping liquid pipes Type 7 to 18 6 35 flared Type 25 to 60 9 52 flared Refrigerant piping gas pipes Type 7 to 18 12 7 flared Type 25 to 60 15 88 flared Drain outlet VP25 outer 32 Power supply entry Discharge duct 150 Suspension bolt hole 4 12 x 37 slot Outside air inlet duct connection port 100 SEMI CONCEALED CASSETTE 4 WAY AIR DISCHARGE io suspension bolt pitch _ eet om Panel center 86010910 ceiling opening dimension Ze suspension bolt pitch
51. NOMINAL CONDITIONS Cooling Heating additional 1 row coil Sound pressure level Entering Air Temperature 27 C db 19 C wb 20 C At 2m distance in closed environment Entering Water Temperature 70 C 100m volume with 0 5 sec reverberation time Leaving Water Temperature 12C 60 56 Convenient system control Sanyo control equipment meets the needs of various of customers Operation system Individual control systems Operation from Quick and Daily and MEAE erac each seat easy operation weekly program External appearance Wired remote Wireless remote Simplified remote Schedule ti controller controller controller model name RCS TM80BG RCS XM18BG WL RCS KR1AGB SHA TM64AGB RCS SH80BG WL RCS SS80BG WL RCS BH80BG WL RCS TRP80BG WL RCS SH1BG Number of indoor 64 units which can be 1 group 8 units 1 group 8 units 1 group 8 units groups controlled max 64 units Power supply from the system controller to 2 units be to 2 units can be Up to 2 units can be When there is no Use limitations connected per group connected per group connected per group system controller connection is possible to the T10 terminal of an indoor unit Connectable 4 amp 5 series indoor unit 4 amp 5 series indoor unit 4 amp 5 series indoor unit 4 amp 5 series indoor unit indoor unit ON OFF 57 Mode setting Tempera
52. Reduced installation cost and circulating pump power The water heat exchanger is a split type which reduces installation costs and allows the use of a less powerful circulating pump improved PCB of water heat exchanger Because of S Link Communication protocol It is able to be controlled by system controller as normal indoor system One touch changeover between cooling and heating operation e Can handle up to 120m of piping i r The system can accommodate up to 120m actual length of a piping between the outdoor unit and the water heat exchanger so a Y uz choosing an installation location is easy RCS TM80BG Water Heat Exchanger unit Model No SGP WE80M1 SGP WE170M1 Cooli ty kW w SGP EW120M2G2w OO racy Heating capacity kW 30 39 5 Cooli t kW 2 T SGP EWi150M2G2W O 2222077 2 Heating capacity kW 30 45 SGP EW190M2G2W Cooling capacity kW 25 50 SGP EGW190M2G2W Heating capacity kW 30 60 Cooling capacit kW 25 56 SGP EW240M2G2W Heating capacity kW 30 67 Cooling power kW Electrical consumption 0 kW 0 01 0 01 Power supply 220 230 240 V Single Phase 50 Hz Height mm 1 000 External dimensions Width mm 550 Depth mm 965 Weight kg 125 160 Standard cold hot water flow rate m h 4 3 8 6 Hydrostatic loss kPa 8 5 11 3 Holding water quantity inside the unit m 0 01 0 02 Minimum holding water q
53. Think GAIA SAWYO Gas Heat Pump Air Conditioners M Series ELECTRIC VRF COMMERCIAL SPLIT SYSTEMS ROOM AIR CONDITIONERS M Grower ECOG 7777 W MULTI W MLLTI as SWAY MULTI ECOG SWAY MULTI HM ink GAIA 3 and the Earth GAIA is a term the infini It des i 7 EE OA AP Ia O I O ee Ld G Power ES W Mutti 3 WAY Multi Water Heat Exchanger XM Semi Concealed Cassette 600x600 4 Way Air Discharge Xt Semi Concealed Cassette 9P 4 WayAir Discharge XMR Semi Concealed Cassette 600 x 600 qe 4 Way Air Discharge Semi Concealed Cassette SR 2 Way Air Discharge Semi Concealed Cassette ADR ype 1 Way Air Discharge Semi Concealed Slim Cassette U type Concealed Duct Concealed Rectangle UR Duct US Concealed Duct Floor Ceiling FUR Slim Concealed Duct UMR Concealed Duct Concealed Duct DR ype High Static Pressure History of SANYO GHP SANYO is one of leading company of GHP system in the world T type Ceiling Mounted Units Floor Ceiling Mounted FTR Units type Wall Mounted Units 1981 Development of GHP as a national project 1985 World First W Selling GHP 15HP launched in Japan KR type Wall Mounted Units 199
54. al dimension 171 186 Flange external dimension 186 1000 irae 5096 SM 700 E Flange external 1080 dimension 150 dimension Suspension bolt pitch 1 65 TODO r 1 Discharge side Discharge side Suspension bolt pitch 580 ee bolt pitch 364 604 262 Flange external dimension w e Suction side o Piping connection Liquid Flared Piping connection Gas Flared 1 00 O1 w Flange external dimension 1426 100Px13 1300 00 2 200 100 E 26 03 1 hole Q Drain piping connection port VP25 outer 232 200 flexible hose accessory port 4507 field supply Lower drain port VP25 outer 32 Suspension fitting 4 12 x 37 slot Power supply inlet 2 230 6 Outside air inlet 2150 irregular opening mamma O a aa m amp Discharge angle duct adapter flange 43 100 43 100Px11 1100 NET 1 262 Flange external dimension Inspection li
55. ange of oil and refrigerant through a balance pipe gas pipe fluid pipe balance pipe i p System chain diagram electronic electronic control Y control valve Indoor units Indoor units Outdoor units Outdoor units Saving Energy Energy savings achieved by the Appropriate Load Divider Function Energy savings are achieved by the Appropriate Load Divider Function which enables efficient operation by concentrating the cooling heating capacity to one outdoor unit and stopping the other Compared to conventional machines with a similar COP this function allows an achievement of energy savings and thus reduces the running costs especially in part load seasons like spring and autumn Non stop operation even during maintainance System will not stop even during maintenance due to Manual Backup Operating Function Maintenance is possible during weekdays because it can continue operating during maintenance Automatic Backup Operating Function enables continuous operation even during trouble If one outdoor unit stops due to unexpected trouble backup function in operational outdoor units will automatically kick in and continue operating Even when a necessity for a service arises one can cut off the system being served with the closing valve in the outdoor unit enabling continuous operation with functional outdoor units Depending on the content of trouble automatic backup operation might not b
56. ated conditions Cooling Indoor air temperature 27 DB 19 C WB outdoor air temperature 35 DB The values in forthe external static pressure and operating sound are for use of booster cable Data subject to change without notice Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Air conveyor Optional part J 801 DEREN 782 o o o 3 3 o Condensate drain piping tubing joint narrow tube 164 224 type Front view Refrigerant Dimensions mm Refrigerant tubing joint wide tube Rear view Air conveyor Optional part D 18mm Condensate drain piping 0200 9200 9200 Refrigerant tubing joint narrow tube ee oe CN 70 943 Front view Refrigerant tubing side Refrigerant tubing joint wide tube Rear view Refrigerant tubing side CONCEALED DUCT 41 Option E lt 76 96 type Wired remote controller RCS TM80BG RCS BH80BG WL eWireless remote controller Simplified remote controller RCS KR1AGB Rap valve kit The types 76 and 96 require two rap valve kits for each unit ATK RX160AGB High static pressure low noise des
57. ating capacity kW 215 59 4 2 5 0 6 3 70 BTU h 8 500 11 000 14 000 17 000 21 000 24 000 Cooling kW 0 03 7 0 037 0 037 0 065 0 065 0 065 0 088 0 088 0 088 Heating 0 037 0 037 0 037 0 065 0 065 0 065 0 088 0 088 0 088 Cooling A OMEN 0 29 0 29 0 29 0 41 0 41 0 41 Heating A 0 17 0 17 0 17 0 29 0 29 0 29 0 41 0 41 0 41 Type Sirocco fan Airflow rate H M L m min 7 8 6 3 5 6 10 3 9 7 5 11 3 10 8 7 Output kW 0 04 0 07 0 09 External static pressure Pa 75 10 Power sound level H M L dB A 48 41 37 56 52 44 60 56 51 Pressure sound level H M L dB A 37 30 26 45 41 33 49 45 40 Height mm 190 Dimensions Width mm 890 Depth mm 614 Liquid Flare mm 6 35 1 4 Piping connections Gas Flare mm 12 7 1 2 Drain piping VP 26 Net weight kg 25 Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data The values in for the external static pressure and operating sound are for use of booster cable Data subject to change without notice Dimensions mm FLOOR CEILING SLIM CONCEALED DUCT CONCEALED DUCT Option e Timer remote controller g RCS BH80AG WLB RCS TM80BG eWireless remo
58. ax Med Min kW TISS 21012 352 085 3 60 3 10 2 65 E599 30 295 5 30 4 50 3 90 5 50 5 00 4 20 5 50 5 00 4 20 Air flow Max Med Min m h 300 240 190 450 360 290 600 480 380 150 600 480 1000 800 650 1200 950 750 1200 950 750 Absorbed power Max Med Min W 50 37 25 60 50 45 87 80 60 95 80 65 130 85 65 180 145 120 180 145 120 Water flow cooling Max Med Min l h 260 225 190 430 370 310 600 500 425 690 590 500 825 715 620 1020 875 740 1135 950 795 Water pressure drop heating Max Med Min kPa 5 7 4 3 3 2 14 1 10 6 7 9 19 21070 SNS 21 8 20 5 16 8 2i 10120 4 5 3 3 2 4 Water flow heating Max Med Min l h 150 120 110 235 205 180 310 270 230 315 285 250 460 390 340 415 435 365 415 435 365 Water pressure drop heating Max Med Min kPa 219 8 6 6 7 5 3 PANN LT MAES SBMA 6 9 5 8 4 3 6 9 5 8 4 3 Sound power level Lw dB A 51 45 40 54 50 42 51 42 37 54 48 45 59 54 48 60 55 48 60 55 48 Sound pressure level Lp Max Med Min dB A 42 36 31 45 41 33 42 33 28 45 39 36 50 45 39 51 46 39 51 46 39 Dimensions H W D S VMC mm 530x775x225 530 990 225 530x1205x225 530x1205x225 530x1420x225 530 1420 255 530x1420x255 Dimensions H W D S HMC mm 225x775x530 225x990x530 225x1205x530 225x1205x530 225x1420x530 255x1420x530 255x1420x530 Dimensions H W D S VHC mm 530x510x218 530x725x218 530x940x218 530x940x218 530x1155x218 530x1155x248 530x1155x248 Weight kg 17 24 21 28 33 43 48 Weight kg 17 24 27 28 2 43 48 Weight S VHC kg 16 23 26 27 i 40 45
59. been raised 300 mm by 63 mm over existing models mere O so operation can be started from the ceiling and pipe layout design has greater 850 mm freedom or less Indoor units specifications Power source ADR74GXH56B ADR94GXH56B ADR124GXH56B 220 230 240V 1 phase 50 60 Hz Cooling capacity ON 2 2 28 3 6 BTU h 7 500 9 600 12 000 Heating capacity 25 2 ur BTU h 8 500 11 000 14 000 p Cooling kW 0 060 0 061 0 063 0 064 0 064 0 067 ower Input Heating kW 0 037 0 037 0 038 0 039 0 039 0 04 22210168 0 24 0 23 0 22 0 25 0 24 0 24 Heating A 0 16 0 16 0 16 017 017017 Type Sirocco fan 1 Fan motor Airflow rate H M L m min 8 7 6 9 8 7 Output kW 0 02 Power sound level H M L dB A 44 42 40 47 45 42 Pressure sound level H M L dB A 33 31 29 36 34 31 Height mm 300 lt 30 gt Dimensions Width mm 600 lt 760 gt Depth mm 560 lt 620 gt Liquid Flare mm 6 35 Piping connections Gas Flare 12 7 Drain piping VP 25 Net weight kg 17 1T lt 25 gt Rated conditions The values in lt gt for external dimensions and net weight are the values for the optional ceiling panel Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data
60. binations are possible Operation local permission stop local prohibition only local permission etc O Local prohibition and the combination of the three items of temperature setting mode change and operation stop can be set at the time of installation A function for pausing the timer in case of national holidays has been added and timer operation also can be stopped for a long time O By setting holidays or operation stop within one week the timer can be paused just for that week OAII timer settings can be stopped with the timer ON OFF effective button Return to timer operation is made by pressing the button again Connection example 2 power supply from the central controller System controller Schedule timer Indoor outdoor operation wire Zone 1 Centralized addresses 1 to 16 Zone 2 Centralized addresses 17 10 32 Zone 3 Centralized addresses 33 to 48 Timer group 6 Centralized addresses 41 to 48 i nr Zone 1 Centralized addresses 49 to 64 1 Sees eee Soe eee eee eee 0220500111751 60 CONVENIENT SYSTEM CONTROL Convenient system control System controller SHA KC64AGB e Individual control is possible for max 64 groups 64 indoor units O Control of 64 indoor units divided into 4 zones One zone can have up to 16 groups and one group can have up to 8 units O Control is possible for
61. can be easily removed 4 Install a suitable water removal valve and air removal valve in the water pipes If air becomes mixed with the liquid in the pipes this can cause noise corrosion and reduced performance 5 Make sure that there is always at least the minimum quantity of water 0 3m in the system if the water quantity is small provide a storage tank or similar If there is insufficient water in the unit this will cause the system to stop frequently or to breakdown 6 Provide a water thermometer and flow rate adjustment valve so that during test running it is possible to adjust the cold hot water flow rate while watching the water temperature Also after adjusting do not touch the adjustment valve 9 The hot and cold water flow rate should be within the range shown in Figure 3 If used outside this range then it could cause breakdown due to corrosion or freezing of the water heat exchanger unit 10 Provide sufficient insulation to the water pipes If insufficient insulation is provided then this will result in loss of heat Also in a severe cold period damage due to freezing of the pipes can occur 11 Within the water heat exchanger unit there is a circuit such that if the external air temperature and the temperature of the water within the unit fall the hot and cold water circulation pump automatically starts to prevent freezing within the water heat exchanger unit However if the unit location or
62. controller SHA KT256EG IM LLL It is also possible to change the prohibition items application Display sample e Max 256 indoor units 4 systems x 64 units can be controlled In case of three or more systems a communication adapter SHA KA128AG must be installed on the outside Operation is possible as batch in zone units in tenant units and in group units ON OFF operation mode setting temperature setting for speed setting air flow direction setting when used without a remote controller and remote controller local operation prohibition prohibition 1 2 3 4 can be done system without a remote controller is possible Joint use with a remote controller or a system controller etc also is possible Use of a schedule timer and holiday setting also can be done Proportional distribution of the air conditioning energy is possible 9 Input pulse signal from Electric or Gas consumption meter n case of joint use with a wireless remote control system there are limitations for the control mode Please use only with Permission and Prohibition 1 Pus Linked system No 1 Intelligent controller Limitation contents There is no limitation for the operation of the remote controller However Individual the contents will be changed to the contents of the controller operated last RS 485 Last pressed priority pez Linked system No 2
63. ct for your Sanyo Gas Heat Pump a great value because it not only ensures Energy saving that problems will be fixed but it helps reduce running costs and improve comfort and economical efficiency as well 24 CERTIFIED mM 45001 8801 52 Indicates conformation ISO 9001 2001 ISO 14001 2001 with EC Directives Certificate Number JO116B Certificate Number ECOOJ0303 33 SANYO reserves the right to make any variation in specifi cation to the equipment described or to withdraw or replace products without prior notification or public announcement All descriptions illustrations drawings and specifi cations in this publication are given in good faith but are intended to present only general particulars and shall not form any part of the contract For full installation details please contact your SANYO distributor REF GHPMSGO8V1 Rating Conditions The cooling and heating capacities are based on the following conditions Cooling Indoor temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Indoor temperature 20 C DB Outdoor Temperature 7 C DB 6 C WB co Printed using paper produced from 5096 recycled material and 5096 from sustainable forestry Www sanyoaircon eu SANYO Electric Co Ltd SANYO Airconditioners Europe S r l 2008 5 SANYO SSP030
64. d Flange sms 1480 Electric equipment box dimension CUT RN IP MCI Wind shielding panel Suction angle duct adapter flange JL AK AK AK 9 Discharge angle duct adapter flange m Suspension bolt pitch 28 03 3 hole Discharge side Option D e Timer remote controller RCS TM80BG RCS BH80BG WL eWireless remote controller eSimplified remote controller RCS KR1AGB Ultra slim profile 200 mm for all models ll Drain pump with increased power By adoption of a high lift drain pump Up to 300 mm the drain piping rise height could be increased to 785 mm from the 500 285 lower surface of the body ideal for hotel application with very thin false ceiling ll Extremely silent 25 dB A at low speed Class 7 Bl Anti mould washable filters included Easy maintenance and service by external PCB box ll Three speed centrifugal fan by wired or wireless remote controller Indoor units specifications Power source US075XH US095XH US125XH US165XH 220 230 240V 1 phase 50 60Hz US185XH
65. e packing pad can be used for the ceiling opening dimensions and for adjustment of the height of the indoor unit Panel opening holes and panel center M5xL40 accessory black screw e Even large ceiling panels can be installed easily by the provisional fastening method Movable fitting side Fixed fitting side ll Adoption of a power up drain pump Drain up is possible up to 500 mm from the drain port i ER mm or less A i 500 mm or less v F310 mm ms e Maintenance of the drain pump is possible from two sides from the left piping side and from the inside of the unit Simple maintenance The drain pan is equipped with site wiring and can be removed The fan case has a split construction and the fan motor and the fan can be removed easily when the lower case is removed Indoor units specifications SPW SR74GXH56B SR94GXH56B SR124GXH56B SR164GXH56B SR184GXH56B SR254GXH56B Power source 220 230 240V 1 phase 50 60 Hz Cooling capacity kW 202 2 8 9 4 5 56 13 BTU h 7 500 9 600 12 000 15 000 19 000 25 000 capacity kW 25 92 4 2 5 0 6 3 8 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 Seer THN Cooling kW 0 086 0 090 0 095 0 086 0 092 0 097 0 088 0 093 0 099 0 091 0 097 0 103 0 135 0 145 0 154 Heating kW 0 055 0 058 0 062 0 055 0 060 0 064 0 057 0 061 0 066 0 060 0 065
66. e possible Automatic backup operation is provisional Please contact the service immediately During backup operation please limit the number of operating indoor units If too many indoor units are operating ability of air conditioning could be lost Long lifetime Energy savings achieved by the Appropriate Load Divider Function Due to the appropriate load divider up to 3096 of operating hours can be reduced During the period such as spring and autumn when the load is low appropriate load divider will stop excess outdoor units When comparing the total of operating hours maximum of up to 3096 reduction is possible Reduction effects can vary depending on the combination of machines and operating condition trial by our company a Renewal period prolonged due to rotation function Rotation function which is run from outdoor units with low operating time will average the operating hours of each outdoor unit This will result in prolongation of maintanance or replacement period Ease of construction Ease of construction is improved by introducing large capacity common pipe By combining all pipes which were needed for each indoor unit into a common pipe in each system the number of pipes are reduced by half which leads to ease of construction Furthermore space of pipes within pipe shafts can be reduced by 2 3 System with approximately 40hp 20hp x 2 units around 10hp System stops during mai
67. g piping as of December 2007 Long piping lengths of 170m are possible with The longest in a real length of 200 m 3 the fiam This is the longest in the Industry LL The vertical interval The 3WAY multi and renewed W multi are considerable of the system is 50m length of 145 m real length of 120 m The real length 170 m The ries aad length of 200 m Between the indoor unit The vertical interval 15m Reduced driving sounds and vibration levels Quieter design means sound levels reduced by up to 2dB A When in quieter mode the capacity is 10 down The driving sound of M Series dB A 120 model 150 model 190 model 240 model Remarkably quiet Comparing the driving sound dB A Sound levels have been reduced to such a degree that Series GHP is now 65 P 60 58 quieter than a normal speaking voice 60 dB A B series H1series series D m m 190 model 1990 2001 Powerful electricity generation This is a commercial use gas heat pump air conditioner for the next generation New GHP with electrical power generator Generation G Power Power does only compensate the electic usage of the outdoor unit but also supplies electricity outside the unit thanks to the power conditioner It comsumes no electricity for cooling or Generation capacity KW heating Generation efficiency Increased consumption of gas by the power generation kW FAN FAN Save
68. he outdoor unit is to be used make sure the installation pad is constructed so that water drops and oily or greasy dirt will not drip down into the area below Do not use a pad fabricated by metal punching or similar process FEATURES High technology features WIDE Wider operation Cooling can be performed throughout the E Automatic restart year for computer rooms banquet halls function for power etc Wider operation range covers outdoor failure cnn temperatures of as low as 10 C DB for Rated E n o cooling and 21 C WB for heating Even when power failure occurs preset Condition programmed operation can be Heating reactivated once power is resumed 2 e 3 E 5 Self diagnosing function By using electronic control valves for E E Details of past record of warnings are O igs A stored and can be verified on the liquid crystal display This makes it easier to C eraser aE diagnose malfunctions greatly reducing Indoor air intake temp WB Indoor air intake temp C DB Service labor Simple convenient features Indoor Units Automatic fan operation Mild Dry Comfortable auto flap en DRY control AUTO Convenient microprocessor control By intermittent control of compressor When the unit is first turned on flap automatically adjusts fan speed to High and indoor unit s fan New Mild Dry position is automatically adjusted Medium or Low corresponding to r
69. hout a remote controller is possible For joint use with a remote control switch use the remote control switch as main remote controller Up to 8 on off controller 4 main 4 sub can be installed in one link system The operation status can be determined immediately As operation mode and temperature settings are not possible with the ON OFF controller it must be used together with a remote controller a system controller etc 63 CONTROL EQUIPMENT EXTERNAL APPEARANCE DRAWINGS eSimplified remote controller RCS KR1AGB eTimer remote controller eWireless remote controller eRemote sensor RCS TM80BG ART K45AGB A T EN 61 195 eSeparate receiver for Em wireless remote controller 70 4 4 9 4 slot Ws eo N 1 E Y 4 4 x 5 4 slot 4 x 5 4 slo Me 120 13 oT aaa eSystem controller elntelligent controller eCommunication adapter SHA KC64AGB SHA KT256EG SHA KA128AG B 116 280 200 238 20 118 1 O FIN N NIN N 8 e ON OFF controller eSeri Para I O unit for 16 groups indoor unit
70. if the insulation to the water pipes is insufficient the temperature of the water in the pump and hot and cold water pipes might fall and freeze before the temperature of the water in the unit falls In this situation provide a circuit which detects the outdoor air temperature at the position of the whole water circulation system where the water temperature falls fastest so that the hot and cold water circulation pump can automatically start Attach suitable suspension fittings to the pipes so that no unreasonable load is applied to the water heat exchanger unit 3 WAY MULTI Design of tubing WATER HEAT EXCHANGER INSTALLATION INSTRUCTION 72 75 Precautions Securing adequate space for servicing 1 Several units can be installed in series Install the outdoor unit in a well ventilated location that will help the heat exchanger work at its optimum level Be sure to secure enough space for maintenance work referring to the diagram below for minimum clearances When installing up to three units in series provide a passageway between units for servicing When installing one unit x A passageway for servicing can be provided on either the left or right side of the unit At least 2000 Be sure to secure an installation space with the following clearances When installing more than one unit in series Atleast 100 At least 100 Atleast 100 At least 100 At least 350 At lea
71. ifications subject to change without notice 12 13 SWAY MULTI With a refrigerant piping system it is possible to have both cooling and heating at the same time This is a heat recovery system highly effective in saving energy and heating simultaneously with outdoor unit energy Heater S Electromagnetic valve kit Example The heat recovery system is excellent for saving Normally the heat extracted from the room which is to be cooled is discharged from outdoor units It reduces the load for compressors and heat exchangers on outdoor units and contributes to saving energy Heater Electromagnetic Ss OV valve kit Heater RO NS Variable Refrigerant Flow products Cooling capacity kW 45 0 56 0 71 0 Capacity STD kW 50 0 63 0 80 0 Low temp kW 53 0 67 0 75D Electricity C Power kW 16 1 35 1 35 Power kW 1 07 1 01 1 54 9 kW 31 6 SOLO 60 9 Gas consumption H STD kW 36 1 43 0 58 0 H LOW kW ANY 56 4 64 9 Cooling 1 37 141 1 14 Heating 1199 8 1 34 AVE 1 36 1 42 1 24 Size Height x Width x Depth mm 2 248 x 1 800 x 1 000 60 Weight kg 845 845 875 Starter Amperes A 30 Gas 928 58 Discharge 9 22 22 225 4 Liquid 2 19 05 Fuel gas R3 4 Bolt thread Exhaust drain mm 9 25 Rubber hose Operation sound dB 57 58 62 Indoor Outdoor ca
72. ign Embedded ceiling type with high static pressure and excellent low operating sound features As the discharge port also can be set freely it is suitable for the office space lll Rap valve kit Except for use as a single system two rap valve kits are required for each unit for the type 76 and the type 96 Single system ul Distribution joint kit APR RP160AG APR P160 for type 76 APR RP680AG APR P680 for type 96 e Short duct use of the type DR When the type DR is used with a short duct duct length of 4 to 5 m external static pressure around 49 Pa 5 mm Aq the air volume and the operating sound maybe too large and an air volume adjustment damper or similar should be installed The external static pressure for this model is 147 Pa 15 mm Ag or more In such a case we recommend that you check use of the type UR Indoor units specifications DR254GXH56B DR364GXH56B DR484GXH56B DR964GXH56B DR764GXH56B Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data 25 48 type 7 X 100 700 22 3 2 holes 55
73. le Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Data subject to change without notice Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Dimensions mm CONCEALED DUCT 5 gt lt D 260 ge external imension Flan dimension 4 Flan d 24 662 ig 962 Flange external dimension Flange external dimension 31 200Px3 600 31 12 03 3 hole 3 180P x 5 900 31 16 233 hole 200 nspection port 4507 ma Inspection port 450 field SD n i s 180 tel 2 d supply sion bolt pitch 580 25 Suspension bolt pitch zr O1 25 IEE 700 1000 _ 40 1 780 Suspension bolt pitch inspection port 4507 1080 Suspension bolt pitch 150 field supply Li a port 4507 field supply 364 604 Refrigerant piping _9 18 6 35 flared liquid pipes 25 60 9 52 flared Refrigerant piping 9 18 12 7 flared gas pipes o 15 88 flared Flange external dimension Flange external dimension D 1442 fie 230P x6 1380 Drain piping connection port VP25 outer Inspection pon 4507 32 200 flexible hose accessory Suspension fitting 4 12 x 37 slot Power supply inlet 2 0 30 Outside air inlet 2 150 irregular opening 580 25 Suspension bolt pitch
74. n equipment clean without a sense of incongruity is possible even in a small space Lighter and smaller units make the installation easy il Washable front panel The height has been removed by approx 2096 and an extremely thin design has been realized The indoor unit s front panel can be easily removed and washed for trouble free cleaning Ao o m m f NEW Current 1000 mm 28 Current 3 Silent design Piping outlet in three directions Low sound in the top class of the industry has Piping outlet is possible in the three directions of rear been realized making these models most suitable for ane SHG Gack hotels and hospitals 9 dB A 50 _ _ ll Anti mold filters are standard equipment 40 35 IMPORTANT When indoor unit are installed in a calm place where low Current 4 series Current 4 series Current 4 series noise is required such as hotel rooms bed rooms or VIP rooms and so on noise from Electronic Expansion Valve controlling refrigerant flow may be offensive to ear during cooling and heating operation In order to prevent the noise please install optional External Electronic Expansion Valve Kit ATK SVRK56BG ATK SVRK160BG with 254 type at narrow tube 5 to 15m away from indoor unit 49 Power source Indoor units specificati
75. n by adoption of newly developed DC fan motors with variable speed new heat exchangers etc Even after installation fine adjustment of the suspension height is possible easily by removing 025 the corner pockets 0 20 Ne W Light thin and attractive design with easy installation 0 10 The direction of the air intake grille 0 08 1 can be changed 0 0 035 A wireless remote control light model 4series 4 series CUN 4 series receiver can be installed by changing CETT D the corner cover The installation can be done in a short time W Discharge opening and flap with new shape Wt The condensate and dirt appearing near the discharge ports 5i Easy servicing of the drain pan of the conventional ceiling cassettes have been reduced A large diameter 45 mm drain pan inspection port has been provided and gt drain and drain pump can be cleaned easily us r Lm i gr cT 2 Z o gt b TN mer z Current New ceiling cassette n EU d The discharged air hits the Upward air flow is suppressed ceiling and causes dirt i CBS nspection The flap can be removed easily for washing with water drain height of approx 850 mm from the ceiling surface Up to 300 mm The drain height could be increased by approx 350 mm over the conventional value by adoption of a high
76. nd anti bacteria washable filters Horizontal flap swinging or set on a fixed position Ceiling Installation Indoor units specifications FTR74EXH56B FTR94EXH56B FTR124EXH56B FTR164EXH56B FTR184EXH56B FTR224EXH56B Power source 220 230 240V 1 phase 50 Hz capa kW 22 2 8 36 45 56 6 4 BTU h 7 500 9 600 12 000 15 000 19 000 22 000 25 32 42 5 0 6 3 7 0 BTU h 8 500 11 000 14 000 17 000 21 000 24 000 Power i Cooling kW 0 65 0 65 0 65 0 88 0 88 0 88 ower input Ere Heating kW 0 65 0 65 0 65 0 88 0 88 0 88 coca 0 29 0 29 0 29 0 41 0 41 0 41 pU Heating 0 29 0 29 0 29 0 41 0 41 0 41 Type Sirocco fan Fan motor Airflow rate H M L m min 106076 12 10 8 9 7 15 13 5 12 Output KW 0 07 0 09 Power sound level H M L dB A 60 54 49 62 58 54 63 60 57 Pressure sound level H M L dB A 49 43 38 51 47 43 52 49 46 Height mm 680 Dimensions Width mm 900 Depth mm 190 Liquid Flare mm 6 35 1 4 Piping connections Gas Flare 2702 Drain piping VP 26 Net weight kg 2505 Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air tempera
77. ndition with Effective perimeter handling is possible high interior quality with simple work execution Compact and effective air conditioning is performed with As indoor units of a multi system the perimeter zone embedding in perimeter counters Most suitable for is handled effectively perimeter air handling in hotels etc ll Large window space can be taken The simple external appearance and the streamlined layout make it possible to secure a large window space unit height 615mm Most suitable for perimeter air conditioning in hotels etc A wired remote controller can be installed in the body Indoor units specifications Concealed Floor Standing type Power source 220 230 240V 1 phase 50 60 Hz kW A 2 8 26 45 56 el BTU h 7500 9 600 12 000 15 000 19 000 24 000 Heating capacity kW 25 3 2 2 50 6 3 8 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 Soar o Cooling kW 0 051 0 056 0 061 0 079 0 085 0 091 0 116 0 126 0 136 0 150 0 160 0 1 70 Heating kW 0 036 0 040 0 045 0 064 0 070 0 076 0 079 0 091 0 101 0 110 0 120 0 130 Running amperes Cooling A 0 24 0 25 0 26 0 37 0 38 0 39 0 54 0 56 0 58 0 70 0 72 0 73 Heating A 0 30 0 31 0 32 0 37 0 41 0 43 0 52 0 54 0 56 Ty
78. ns Width mm 700 1000 1480 Depth mm 630 Piping Liquid Flare mm 6 35 1 4 9 52 3 8 connections Gas Flare mm 17252 CUP 15 88 5 8 Drain piping VP 25 Net weight kg 24 25 52 47 Rated conditions The values in for the external static pressure and operating sound are for use of booster cable Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Data subject to change without notice Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Dimensions mm Filter 437x241 x2 74 184 Filter 608x241 x1 2 254 304 dimension Flange external Suction side 2 Suction side E 310 319 A zl I z o A 25d Flange external dimension 5 262 Flange SE dimension 27 mS 31 a 946 T ad 100Px5 500 78 175 100Px9 900 M 5 cR du He 5 T E 19 Ea g 18 3 1 hole 26 3 1 hole 1 lal b S b D Si 4 262 ange dimension N oO CONCEALED RECTANGLE DUCT TYPE Hi 1243 3 hole 20 03 3 hole Y 4 2 n B t c T 43 hool 43 96 00Px3 300 196 ae Tho b gt 5 41 L141 to0px7 700 700 41 492 1161 020 extern
79. ntenance Machine in need of maintenance Maintenance during holidays Up to this time around 10hp PEN Up to this time t A A Operating Y Operating 4 Machine in need of maintenance Continuous operation under the maintenance W MULTI Example 40hp approximately 20hp x 2 load of around 20hp 8 operating hours around 20hp t Fiscu Maintenance during weekdays Example of the rotation function stop stop 1 Operating hours 2100hr 2050 realization of averaging operating hours Operating hours A 2105hr B 2058hr Load reduced Only machine is operating Example of a system with System startup Only unit 1 operating Operating hours 2100 2053 Load increased Machine A and Gare operating approximately 40hp Combining all pipes which were needed for each outdoor unit into a pipe in each system Number of pipes is reduced by half Up to this time 20hp 20hp 10 11 W MULTI Variable Refrigerant Flow products HP 26 Cooling capacity 450 7 0 DRE SI 50 0 80 0 Capacity Heating capacity ERE T TT Hot water Cooling mode 16 0 24 0 Electricity C Power 1 35 70 H Power 1 01 2 02 G 5 49 0 Gas consumption H STD 36 1 56 2 H LOW ATES Vo Cooling 187 1 40 Heating 1 35 1 37 AVE 1 36 1 39
80. ntrol in the room FT also available with infrared remote controller e Wide model range for 2 pipe and 4 pipe design system X type size 031 and 051 e Silent operation ensures maximum Cleanable air filter standard included comfort Suitable for any commercial buildings and even for hotels and residential applications type FW X031EH5 e FW X051EH5 FW X061EH5 FW X081EH5 e FW X101EH5 fay 5 Main power supply V Ph Hz 230 1 N 50 Total cooling capacity Max Med Min kW 35 215 4 70 4 10 3 60 6 00 5 00 4 20 7 60 6 00 5 00 9 92 8 09 6 23 Sensible cooling capacity Max Med Min kW 3172 5 20 2 90 4 70 3 80 3 20 6 00 4 70 3 80 1 90 6 22 4 62 Heating capacity Max Med Min kW 3 49 3 11 2 83 5 70 4 85 4 35 7 70 6 40 5 40 9 00 7 70 6 40 13 00 10 60 8 16 Air flow Max Med Min mh 520 460 400 750 630 530 1300 1060 850 1470 1300 1060 2300 1700 1200 Absorbed power Max Med Min W 60 50 40 90 70 60 120 90 80 150 120 90 180 130 110 Water flow Max Med Min l h 430 395 360 190 690 600 1030 860 720 1300 1030 860 1700 1400 1070 Sound power level Lw Max Med Min dB A 46 44 41 56 51 48 51 44 40 55 51 44 57 49 43 Sound pressure level Lp Max Med Min dB A 37 95 92 41 42 39 42 35 31 46 42 35 48 40 34 Water connections inch 1 2 female 3 4 female Dimensions H W body mm 296x575x575 296x575x575 310x760x760 340x760x1050 340x760x1050 grille panel mm 41x730x730 41x730x730 30x860x860 30x860x1150 30x860x1150
81. ommunication x d 65 DESIGN amp EXECUTION Refrigerant tubing In regard to the refrigerant tubing length Header tube purchased separately System Example Branch tube purchased separately cq T tee provided by installer X Closed pinch weld Li Distance cm from flammable materials LA L2 LB LC LG 8 Bea 1 branch tube Unit main tube Indoor unit between unit branch tubes No 1 branch Unit branch tube Over 4m Limit of elevation difference between indoor units after the final branch ez Difference between longest and a Allowable tubing length A L L2 L4 shortest tubing lengths after the tj No 1 branch first branching point dd 21502 09 Maximum length of each branch tube Maximum length between outdoor units If outdoor unit is above e If outdoor unit is below Allowable elevation difference Maximum difference between indoor units Maximum difference between outdoor units Allowable header L3 Maximum length from the first tubing length tees to the front seal 1 Equivalent length 2 If cooling mode is expected to be used when the external temperature is 10 C or below install so the maximum length is 30 m 3 Install so that the height difference between indoor units afte
82. onger than 90m Equivalent length more than 130 connection ratio Main tubing size LA and Balance tubing size 1204 120 1204150 1504150 1504 190 101 0 31 75 19 05 238 1 22 22 1904 190 1904240 2404 240 e Main tubing size after branch LB LC eindoor unit connection size In 7 18 2 2 5 6 12 7 9 52 Under 16 0kW 22 60 6 4 16 0 15 88 9 52 16 1 22 4 76 22 4 19 05 9 52 22 5 28 0 96 28 222 22 29 52 28 1 5 225 4 212 7 628 58 15 88 35 6 45 0 45 1 71 0 71 1 101 0 Over 101 1 38 1 19 05 38 1 22 22 e Branch Kit table Under 5 6kW 16 1 22 4 22 5 28 0 45 1 71 0 e e E um Over 71 0 lt Regarding more detail information please refer to the Installation manual or Technical data W MULTI Design of tubing Single MULTI Design of tubing WAY MULTI Design of tubing Refrigerant tubing size D In case of standard installation 2 L1 longer than 90m Equivalent length or more than 130 connection ratio Main tubing size LA and Balance tubing size e Main tubing size after branch LB LC Under 8 9kW 9 0 16 0 16 1 28 0 28 1 35 5 028 58 031 75 Under 8 9kW 9 0 16 0 16 1 28 0 28 1 35 5 628 58 628 58 222 22 215 88 Over 36 5 628 58 31 75 25 4 19 05 Under 8 9kW 9 0 16 0 16 1 28 0
83. ons KR74GXH56B KR94GXH56B KR124GXH56B KR164GXH56B 220 230 240V 1 phase 50 60Hz KR184GXH56B KR254GXH56B kW 2 2 2 8 3 6 4 5 5 6 73 BTU h 7 500 9 600 12 000 15 000 19 000 25 000 erie epos kW 2 5 32 4 2 5 0 6 3 8 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 Cooling kW 0 031 0 033 0 035 0 049 0 052 0 055 ower input Heating kW 0 031 0 033 0 035 0 049 0 052 0 055 Sum cape 2221016 0 15 0 15 0 15 0 23 0 23 0 24 Heating A 0 15 0 15 0 15 0 23 0 23 0 24 Cross flow fan 1 Fan motor Airflow rate H M L m min 10 8 6 12 10 8 16 14 10 Output kW 0 011 0 015 0 023 Power sound level H M L dB A 47 43 39 53 49 46 Pressure sound level H M L dB A 36 32 28 42 38 35 Height mm 285 330 Dimensions Width mm 995 1140 Depth mm 203 228 Liquid Flare mm 6 35 9 52 Piping connections Gas Flare mm 12 7 15 88 Drain piping VP 13 Net weight kg 14 21 Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Liquid pipe 26 35 Length Approx 470 mm Gas pipe 212 7 Length Approx 400 mm Drain hose VP13 Length Approx 450 mm Installation fitting Fitting fixing hole 25 hole or 5 x 13 slot Installation fitting piping wiring inlet 280
84. oom gives you comfort It realizes efficient accordance with the cooling or heating sensor and maintains comfortable airflow dehumidification according to room operation This initial flap position can be throughout the room temperature preset within a certain range for both cooling and heating Auto button Is included for continuous movement of to vary airflow direction Air Sweep DP Built in drain pump b 3 Al Auto flap section The air sweep function moves the flap Max head 50cm or 75cm U type from up and down in the air outlet directing the bottom of the unit air in a Sweeping motion around the room and providing comfort in every corner Maintenance and inspection is a must for gas heat pump air conditioning systems Just like an automobile a heat pump air conditioning system requires periodic servicing so that it can perform efficiently Maintenance and inspection Main maintenance and inspection items 1 Changing the engine oil 2 Checking the coolant level A 3 Inspecting the engine system Efficient operation 4 Checking the safety protection system 5 Checking and adjusting the running conditions collecting operating data etc Preserving durability Safe and reliable operation Since a heat pump air conditioning system uses a gas engine as its power source it should be periodically inspected to avoid trouble and keep it running efficiently We recommend a maintenance contra
85. outdoor operation lines to the intelligent controller Also required for connection of the AMY software For more detail please take a look at page 58 Two linked wiring systems can be connected to one SHA KA128AG but max 4 systems can be connected for the entire intelligent controllers As this is not a splash proof design it must be installed indoors or in the control panel etc 62 CONVENIENT SYSTEM CONTROL CONVENIENT SYSTEM CONTROL Seri Para 1 Unit ACC SP16TAG This is the interface for connecting signals from the center control device with the SANYO air condi tioner unit control network This unit can control and monitor the status up to 16 groups of indoor units Max 64 indoor units Up to 4 seri para units can be connected in one system From the center control device it is possible to set the temperature and to monitor the room tempera ture or intake air temperature lll System example Seri para I O 1 On Alarm Answer back Filter sign 2 Room temp Analog DC4 20mA 3 All On Off 1 On Off Pulse DC24V 2 Local prohibit Continuous DC24V 3 Temp setting Analog DC1 5V 4 All On Off Pulse DC24V 5 All local prohibit amp Emergency stop Continuous DC24V 19 U29 Bi LonWorks Interface SHA LN16UGB This interface is a communications converter for connecting LonWorks to the Sanyo air conditioner unit P
86. pacity ratio 50 200 Number of connection indoor 36 36 36 ow temp condition Outdoor temperature 2 C 1 Indoor unit can be connect up to 16kW model Model size 60 Specifications subject to change without notice SWAY MULTI Excellent performance SANYO 3 WAY multi system is capable of simultaneous heating cooling and individual operation of each indoor unit by only one outdoor unit As a result efficient individual air conditioning is possible in buildings having diverse room temperatures Improved maintenance intervals The unit only needs to be serviced every 10 000 hours This is the best in the industry Up to 35 energy saving Effective heat recovery system enables up to 35 energy saving SANYO estimate 22 215 3 WAY MULTI The waste heat removed from the cooled room is effectively used as heat source for the room to be heated As a result the load on the compressor and heat exchanger on the outdoor unit can be Max 36 indoor units reduced enabling excellent heat recovery 3 WAY GHP MULTI enables simultaneous heating and cooling operation through each solenoid valve kit DE de E System example Stop Heating Solenoid Valve Kit ATK RZP56BGWB ATK RZP160BGWB Liquid pipe 7 Flexible system design Dm UE an
87. pe Sirocco fan 1 Sirocco fan 2 Fan motor Airflow rate H M L m3 min 7 6 5 9 7 6 12 9 8 iste 17 14412 Output kW 0 01 0 02 0 02 0 03 0 06 Power sound level H M L dB A 44 41 39 50 46 40 49 46 42 49 46 42 52 49 46 Pressure sound level H M L dB A 33 30 28 39 35 29 38 35 31 39 36 31 41 38 35 Dimensions HxWxD mm 616x904x229 Liquid Flare 6 35 9 52 Piping connections Gas Flare mm 127 15 88 Drain piping VP 20 Net weight kg 21 28 Floor Standing type Power source 220 230 240V 1 phase 50 60 Hz Cooling capacity kW 22 2 8 3 6 AL 5 6 7 1 BTU h 7 500 9 600 12 000 15 000 19 000 24 000 Heating capacity kW 235 22 4 2 50 6 3 8 0 BTU h 8 500 11 000 14 000 17 000 21 000 27 000 Cooling kW 0 051 0 056 0 061 0 079 0 085 0 091 0 116 0 126 0 136 0 150 0 160 0 1 70 Heating kW 0 036 0 040 0 045 0 064 0 070 0 076 0 079 0 091 0 101 0 110 0 120 0 130 siiis Cooling JA 0 24 0 25 0 26 0 37 0 38 0 39 0 54 0 56 0 58 0 70 0 72 0 73 Heating A 0 17 0 18 0 19 0 30 0 31 0 32 0 37 0 41 0 43 0 52 0 54 0 56 Type Sirocco fan 1 Sirocco fan 2 Fan motor Airflow rate H M L m3 min 7 6 5 9 7 6 12 9 8 1518 11 HAA Output kW 0 01 0 02 0 02 0 03 0 06 Power sound level H M L dB A 44 41 39 50 46 40 49 46 42 50 47 42 52 49 46 Pressure sound level H M L dB A 33 30 28 39 35 29 38 35 31 39 36 31 41 38 35 Dimensions HxWxD mm 615 1065 230 615 1360 230 Liquid Flare 6 35 9 52 Piping connections Gas Flare mm 27 15 88
88. peration Setting the flap in the smudge free position suppresses soiling around the air outlet that is seen in conventional ceiling cassettes so the ceiling stays clean at all times The hanging height of the unit can be easily adjusted The up down position of the unit can be easily adjusted by simply removing the panel side covers without having to remove the ceiling panel Separation distance from nearest obstacle Drain height 1 000mm or more 200 AU mm or more T qii or less r 850mm or less 200mm or 200mm or more 1 000mm or more More Indoor units specifications LDR94GXH56B LDR124GXH56B LDR164GXH56B LDR184GXH56B LDR254GXH56B Power source 220 230 240V 1 phase 50 60 Hz Ges kW 2 9 3 6 4 5 5 6 7 3 BTU h 9 600 12 000 15 000 19 000 25 000 erie Gael kW 3 2 4 2 5 0 6 3 8 0 BTU h 11 000 14 000 17 000 21 000 27 000 Power input 2221016 kW 0 050 0 051 0 052 0 058 0 060 0 061 0 086 0 087 0 089 Heating kW 0 039 0 040 0 042 0 046 0 048 0 049 0 075 0 076 0 077 EDO A 0 40 0 39 0 39 0 46 0 46 0 46 0 71 0 70 0 69 Heating A 0 36 0 35 0 35 0 42 0 41 0 41 0 66 0 65 0 63 Type Sirocco fan 2 Fan motor Airflow rate H M L m min 12 10 9 12 11 10 13 11 5 10 18 15 13 Output kW 0 05 Power sound level H M L dB A 47 45 44 47 46 45 49 47 45 56 51 47 Pressure sound level H M L dB A
89. r supply line Em gt P These valves and line is necessary only when humidification is used Using duct unit for supply and circulation air sing duct unit for supply air using back of ceiling for circulation air Indoor units specifications GU055XH GU075XH GU105XH Air circulation H m h 500 750 1 000 Power source 220 230 240V 1 phase 50 Hz Fresh Air Load Cooling kW 82 26 10 7 3 4 Treatment Capacity Heating kW 652 9 8 3 5 12 6 4 6 Enthalpy Exchange Cooling 99 Efficiency Heating 67 Temp Exchange Efficiency 9 715 kW 3 6 5 6 T3 Equivalent cooling capacity BTU h 12 000 19 000 25 000 Pow Cooling kW 0 532 0 532 0 532 0 737 0 737 0 737 0 798 0 798 0 798 Heating kW 0 532 0 532 0 532 0 737 0 737 0 737 0 798 0 798 0 798 Cooling A 2 5 2 4 2 3 3 4 3 2 3 1 3 1 3 5 3 4 Heating A 2 5 2 4 2 3 2292 9 3 7 3 5 3 4 Type Sirocco fan Fan External static pressure Return air Pa 183 170 221 188 135 88 motor External static pressure Supply air Pa 205 182 264 218 176 137 Output kW 0 28 4P x2 0 35 4P x2 Power sound level C H dB A 57 Cooling 58 Heating 58 Cooling 59 Heating 59 Cooling 60 Heating Pressure sound level C H dB A 46 Cooling 47 Heating 47 Cooling 48 Heating 48 Cooling 49 Heating Height mm 425 450 Dimensions Width mm 1785 190
90. r the final branch is within the limits shown in the figure 66 Outdoor Unit External Dimensions Single MULTI Design of tubing Refrigerant tubing size 1 In case of standard installation 2 L1 longer than 90m Equivalent length or more than 130 connection ratio Main tubing size LA and Balance tubing size 35 5 225 4 212 7 45 0 628 58 212 7 02858 01588 71 0 928 58 915 88 e Main tubing size after branch LB LC eindoor unit connection size In Under 16 0kW 16 1 22 4 22 5 28 0 28 710 225 4 512 7 228 58 215 88 Under 16 0kW 15 88 29 52 215 88 99 52 16 1 22 4 22 5 28 0 28 1 35 5 35 6 90 0 Under 16 0kW 16 1 22 4 22 5 28 0 2841005 25 4 12 7 28 58 15 88 35 6 45 0 628 58 12 7 31 75 615 88 45 1 112 0 628 58 615 88 31 75 19 05 Under 16 0kW 16 1 22 4 22 5 28 0 28 1 35 5 35 6 45 0 45 1 142 0 e Branch Kit table Under 16 0kW 16 1 35 5 Over 35 6 e Header Kit table Under 16 0kW 16 1 28 0 28 1 45 0 Over 45 1 Regarding more detail information please refer to the Installation manual or Technical data W MULTI Design of tubing Refrigerant tubing size D In case of standard installation 2 L1 l
91. ral controllers on the same circuit In case of joint use with a wireless remote controller there are limitations for the control mode Please use only with Individual and Central 1 A control mode corresponding to the use condition can be selected from 10 patterns A Operation mode Central control mode or remote control mode can be selected O Central control mode The system controller is used as centralized control device Setting from a remote controller can be prohibited by prohibiting local operation from the system controller Control of systems without a remote controller and of main sub systems a total of up to two units is possible O Remote control mode The system controller is used as a remote controller Setting from the system controller can be prohibited by prohibiting local operation from another Connection example central control unit Controlled unit number mode All mode or zone 1 2 3 4 i A mode can be selected ETE mode All zone or group unit can be selected O Zone 1 2 3 4 mode Setting is possible only for the indoor units of zone 1 2 3 or 4 Individual A Operation mode Central control mode Remote control mode All central control Zone 2 mode Zone 2 central control Zone 2 remote control Example 3 Zone 3 mode Zone 3 central control Example 4 Zone 3 remote control 2 B 3 T S
92. remote controller Em 2 Fi RCS SS80BG WL X DT agua m RCS TM80BG RCS BH80BG WL RCS KR1AGB ePanel PNR S253GHANB For 254 type PNR S124GHB For 74 184 type Realization of thin compact and light units Remarkable size and weight reductions have been realized by improvement of the design around the fan In addition the size for the type 18 has been reduced by one rank compared to current model In case of the type 18 volume Approx 30 reduction Weight body panel Reduction from 50 kg to 30 kg j approx 40 reduction Comparison with the current type 7 type Approx 14 reduction Weight 40 kg to 30 kg body panel approx 25 reduction 25 type Approx 12 reduction 50 kg to 39 kg approx 22 reduction Body volume il Silent design Low operating sound in the top class of the industry have been realized by adoption of high efficiency fans Operation noise 7 type 9 type 30 24 33 26 16 18 type 25 type 35 29 38 33 High low notch dB A Bi Realization of most suitable air flow for heating and cooling Automatic setting to the most suitable flap angle for heating and cooling and an auto swing mechanism for widening of the air flow are provided 12 type 34 28 Auto flap section Heating Hi M Cooling Fan 25 ll Excellent installation performance e Th
93. se the size according to the horsepower after the increase of units gom om eon lt Example of a system gt adm Us PE DM Added outdoor units N Only for models with the same refrigerant S am sae Added indoor units Only for models with the same refrigerant 1 att S If there is a possibility for addition after MM mE Maximum possible number of outdoor units to be 2 units setting up please plan it so that the Main pipe Maximum gas pipe diameter 38 1 Maximum horsepower of combined outdoor units 50hp placement of a ball valve sold Maximum fluid pipe diameter 19 05 Maximum possible number of indoor units to be connected 48 units 1 separately on a branch pipe on Indoor outdoor units capacity ratio 50 13096 2 indoor outdoor units IS possible 1 Maximum possible number of outdoor units to be connected is 24 e 2 Capacity of indoor units connection is Indoor units are same as multi series for buildings Minimum 50 of the capacity of the smallest outdoor unit There exist some indoor units which are un connectable within the system Maximum 13096 total capacity of the system outdoor units Introducing the oil refrigerant balance control system The amounts of oil and refrigerant between compressors are kept in balance by a signal from an oil surface sensor or a refrigerant gas controller mounted on the oil separator allowing the exch
94. st 1000 front side A passageway for servicing can be provided on either the left or right side of the unit Be sure to secure an installation l l At least 1000 space with the following gt clearances At least 2000 At least 150 2 Installing 8 or more outdoor units in series When installing eight or more outdoor units in series or when installing units near a wall or other location where air circulation may be inadequate give sufficient consideration to the possibility of the units shorting out Unit mm At least 600 Refrigerant piping side Front side At least 1000 Unit mm For dispersed installation At least 1000 on both the refrigerant piping side and the front side At least 100 At least 600 on the refrigerant piping side At least 1000 on the At least 600 on the refrigerant piping side At least 1000 on the front side LLLLLLLLLLLLL LL At least 600 At least 150 At least 10 2 least 10 At least 10 At least 10 p Front View Top View TYPE 70 and 90 Top View TYPE 120 150 190 and 240 Avoid the following installation locations Install the unit safely and securely in a place where it will be adequately protected and be able to perform at its designed specifications A place that has no space for servicing Maintenance work can require a large number of instruments and tools
95. sub controller is possible with a simplified remote controller or a wired remote controller up to two units Schedule timer SHA TM64AGB Dimensions H 120 x W 120 x D 16 mm The power supply for the schedule timer is taken from one of the following 1 Control circuit board T10 of a nearby indoor unit Power supply wiring length Within 200 m from the indoor unit 2 System controller Power supply wiring length Within 100 m from the indoor unit When the power supply for the schedule timer is taken from the control circuit board of the indoor unit that indoor unit cannot be used with other control devices using the T10 terminal Connection example 1 power supply from the indoor unit Remote controller Schedule timer As operation mode and temperature settings are not possible with the schedule timer it must be used together with a remote controller a system controller an intelligent controller etc Also as it does not have an address setting function the control function of a system controller etc must be used for address setting Up to 64 groups max 64 indoor units can be controlled divided into 8 timer groups Six program operations Operation Stop Local permission Local prohibition per day can be set in a program for one week Only operation or stop remote controller local permission or remote controller local prohibition and their respective com
96. t Factory setting aa High ceiling setting 42 42 Ceiling mounted installation 2 4 27 1 With one direction type for high ceilings current as of November 2004 2 For setting method refer to the installation instructions that came with the ceiling panel B Lightweight Compact and Quiet With a full model change all models are now the top industrial lightweight units And with all models having coordinated dimensions between the unit and the panel multi unit installations have a smart attractive appearance Current as of November 2004 High Low operation E With types of air blow systems the units can be used in various ways ll Product unit panel weight kg Current model 26 8 kg 16 18 type 27 8 kg 25 type 30 9 kg lil Operating noise dB A Current model 9 12 type 9 12 type 16 type 18 type 25 type 1 One direction down blow system mt Powertul one direction down blow system reaches the floor even from high ceilings up to 4 2m 2 Two direction ceiling mounted system Down blow and front blew systems are combined in a C lling mounted unit to blow air over a wide area 3 One direction ceiling mounted system am 1 This powerful ceiling mounted front blow system efficiently air conditions the space in front of the unit ll Smudge free o
97. t in three directions Piping outlet is possible in the three directions of rear right and left making the installation work easier E Anti mold filters are standard equipment IMPORTANT When indoor unit are installed in a calm place where low noise is required such as hotel rooms bed rooms or VIP rooms and so on noise from Electronic Expansion Valve controlling refrigerant flow may be offensive to ear during cooling and heating operation In order to prevent the noise please install optional External Electronic Expansion Valve Kit ATK SVRK56BG at narrow tube 5 to 15m away from indoor unit Indoor units specifications Rated conditions Cooling Indoor air temperature 27 C DB 19 C WB outdoor air temperature 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data PIETER SIZE OOS SNAKES Front view SPW K075XH K095XH K125XH Power source 220 230 240V 1 phase 50 60Hz Cooling capacity E 22 2 8 3 6 BTU h 7 500 9 600 12 000 Heating capacity RS Am 2 ae JBTU h 8 500 11 000 14 000 Cooling 0 018 0 019 0 019 0 021 0 022 0 023 ower input as Heating kW 0 019 0 019 0 020 0 022 0 023
98. te controller eSimplified remote controller RCS KR1AGB Integrated pump for condensate discharge Fresh air intake Reduced dimensions BIAnti mould and anti bacteria washable filters ll Three speed centrifugal fan by remote control and feature to increase speed pressure using the booster cable Indoor units specifications UMR74EXH56B UMR94EXH56B UMRi124bEXH56B UMR164EXH56B UMR184EXH56B UMR224EXH56B Power source 220 230 240V 1 phase 50 Hz Coalingeapaciy kW 2 2 2 8 3 6 4 5 5 6 6 4 BTU h 7 500 9 600 12 000 15 000 19 000 22 000 Heating kW 25 32 4 2 5 0 6 3 7 0 BTU h 8 500 11 000 14 000 17 000 21 000 24 000 Cooling kW 0 11 0 11 0 11 0 138 0 138 0 138 0 136 0 136 0 136 Heating kW 0 11 0 11 0 11 0 138 0 138 0 138 0 136 0 136 0 136 Cooling A 0 45 0 45 0 45 0 60 0 60 0 60 0 57 0 57 0 57 Heating A 0 45 0 45 0 45 0 60 0 60 0 60 0 57 0 57 0 57 Type Sirocco fan Eom cie Airflow rate H M L m min 10 8 5 7 3 14 6 10 6 7 16 7 11 7 10 Output kW 0 11 0 14 External static pressure Pa 49 Power sound level H M L dB A 54 52 49 54 47 42 57 49 46 Pressure sound level H M L dB A 43 41 38 43 36 31 46 38 35 Height mm 266 Dimensions Width mm 852 1 058 Depth mm 572 Liquid Flare mm 6 35 1 4 Piping connections Gas Flare mm 12 7 1 2 Drain piping VP 18 Net weight kg 30 35 R
99. tom drain port O D 26mm Suspension lug Power supply outlet 2 030 Flange for air intake duct Pl cover Electrical component box Frame filter 9 606 60 9 8 6 6 9 G o Signal output board ACC SG AGB optional 450x450 Field supply MIN 650 Air discharge space Inspection access panel Ceiling 10 3 3 Hole View A Frame Filter Uninstalled CONCEALED DUCT 37 Option OPERATION 59 lt e Timer remote controller eWireless remote controller mum RCS BH80AG WLB RCS TM80BG Simplified remote controller RCS KR1AGB ll Ultra slim profile 190 mm for all models Suitable for horizontal and vertical installation lllideal for hotel application with very thin false ceiling ll Extremely silent 26 dB A at low speed Class 7 9 12 Anti mould washable filters included Easy maintenance and service by air suction port Three speed centrifugal fan by wired or wireless remote controller Indoor units specifications FUR74EXH56B FUR94EXH56B FUR124EXH56B FUR164EXH56B FUR184EXH56B X FUR224EXH56B Power source 220 230 240V 1 phase 50 Hz Cooling CAPAC kW 22 2 8 DID 4 5 56 6 4 BTU h 7 500 9 600 12 000 15 000 19 000 22 000 He
100. ture 35 C DB Heating Indoor air temperature 20 C DB outdoor air temperature 7 C DB 6 C WB Dimensional data Wide tube Data subject to change without notice Dimensions mm Narrow tube Drain hose 226 FLOOR CEILING MOUNTED UNITS n Center of tubing hole 275 4 places WALL MOUNTED UNITS Option RCS TM80BG RCS SH1BG RCS BH80BG WL Timer remote controller eWireless remote controller Simplified remote controller RCS KR1AGB ll Lighter and smaller units make the installation easy The width has been removed by approx 1796 and light weight has been realized e 28 m Current 285mm NEW Current 995mm Silent design Low operation sound in the top class of the industry has been realized making these models most suitable for hotels and hospitals Flat amp Intimate design The compact design and flat face make match the interior and installation without a sense of incongruity is possible even in a smal space Closed discharge port When operation is stopped the flap closes completely to prevent entry of dust into the unit and to keep the equipment clean 47 il Washable front panel The indoor unit s front panel can be easily removed and washed for trouble free cleaning ll Piping outle
101. ture setting Air flow direction Permit Prohibit switching Weekly program eS 1 Select two of the following Fan speed Air flow direction Central Individual and Filter sign 2 Setting is not possible when a remote control unit is present Use the remote control for setting O O O Centralized control systems Operation with various function from center station System controller Only ON OFF operation from center station ON OFF controller Simplified charge ratio for each tenant Touch screen panel Personal computer field supply p Web application Intelligent controller Communication adaptor SHA KC64AGB SHA KC16KAGB SHA KT256EG SHA KA128AGB 64 groups 16 groups 64 units x 4 systems 2 systems max 64 units max 64 units max 256 units max 128 units Up to 10 units can be connected to one system Main unit sub unit 1 main unit 1 sub unit connection is possible Use without remote controller is possible Up to 8 units 4 main units 4 sub units can be connected to one system Use without remote controller is impossible A communication adaptor SHA KA128AGB must be installed for three or more systems 4 amp 5 series indoor unit 4 amp 5 series indoor unit 4 amp 5 series indoor unit 4 amp 5 series indoor unit CONVENIENT SYSTEM CONTROL Con
102. uantity outside the unit 0 28 0 50 Gas pipe mm 22 22 928 58 Piping refrigerant Liquid pipe mm 99 52 915 88 Heat exchanger hot cold heat exchanger Water circuit limit pressure MPa 0 686 Anti freezing protection system Protective Thermostat Specifications subject to change without notice System Mixing Flexibility for 2 WAY GHP e Combined with a water heat exchanger unit the SANYO GHP can create a flexible system the ideal replacement for existing chiller and boiler systems e The GHP Multi System can have an indoor unit plus a GHP chiller When the two systems are operated independently an outdoor unit with 13096 capacity can be connected System example Fan Coil Unit a GHP Chiller Ss Water Heat Exchanger Refrigerant Water Piping Duct o 1l Air Handling Unit NOTE Distance between units must be less than 2m Outdoor unit Water Heat Exchanger m ZAK ES Z Note The mode of running of outdoor unit depends on the water heat exchanger s mode The water pump is not included in the water heat exchanger unit For simultaneous operation however the maximum capacity is 130 Please inquire details of this system design of SANYO Hot Water Supply Function Hot water capacity is approximately 50 of gas consumption at partial load System Advantage The engine waste heat which is normally exhausted into the
103. ustry Auto Flap and Auto Swing Functions The compact design keeps unit ELA M The Auto Flap function lets you set the air direction by width and height to a minimum ED remote control and the Auto Swing function delivers a and delivers the industry s uniform amount of air to every part of the room What is smallest panel width giving you Unit height more the flap can be closed when the unit is not operating plenty of leeway in selecting x Em to keep dust from entering the room an installation space Panel door m width M T60 mm The hanging height of the unit can be Lightweight Construction in the top class of easily adjusted the industry Adjustable covers are equipped on both sides ed of the ceiling panel so that the hanging height With a maximum unit weight of 8 5 kg installation work is f of the unit can be adjusted even after the a snap panel has been installed Weight of Products kg j Adjustable covers both sides of panel 17 2 5 23 3 17 2 5 23 3 12 type 17 2 5 25 3 Quiet Operation in the top class of the industry With operating noise reduced by up to 3 dB A over existing models the unit creates a quiet comfortable room environment Operation noise dB A High Low operation 7 type 9 type 12 Quiet Operation in the top class of the industry The drain height has
104. venient system control Remote controller Wired remote controller Wireless remote controller eSystem example Control contents Part name model No Quantity Standard control eWired remote controller O Control of the various operations of the indoor unit RCS TM80BG by wired or wireless remote controller Cooling or heating mode of the outdoor unit is decided RCS SH80BG WL each by first oressed priority of the remote controller RCS SS80BG WL O Switching between remote controller sensor and RCS BH80BG WL body sensor is possible RCS TRP80BG WL RCS SH1BG 1 Group control Batch remote control of all indoor units Operation of all indoor units in the same mode Up to 8 units can be connected RCS TM80BG 1 unit O The sensor is the body sensor and thermostat ON OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit Remote controller Main Sub Main Sub 2 Main sub remote control Main or sub oe ________ _ OMax 2 remote controllers per indoor unit Main RCS TMSOBG er Standard control 2 Main sub 1 Group control remote controller and sub remote controller can be eiirelsss romole controller remote control connected RCS XM18BG WL ired O The button pressed last has priority RCS SH80BG WL E O Timer setting is possible even with the sub remote RCS SS80BG WL controller RCS BH80BG WL RCS TRP80BG WL RCS SH1BG
105. x connection Accessory copper pipe for gas pipe FLOOR STANDING UNITS CONCEALED FLOOR STANDING UNITS TOTAL HEAT EXCHANGER WITH DX COIL Option Timer remote controller e Wireless remote controller Simplified remote controller E um RCS TM80BG RCS BH80BG WL RCS KR1AGB powerful fresh air incoming to match the W High static pressure available right temperature and humidity indoor condition in medium sized commercial Mi Standard spigots ensure simple connection space to ductwork Integration of heat recovery ventilation and Easy to clean filter prevent mould or DX coil technology for optimum air bacteria from occurring temperature control Easy maintenance and service by out ll High efficiency on both temperature and installation of the electric box humidity condition ll Compact and quiet design Rap valve kit ATK RX160AGB is required for each unit System Outline Intake grille Distribution chamber Inlet gals eal 0 Outlet Rap valve kit ATK RX160AGB 53 RA EA A A Reduce pressure valve RES Stop valve for water supply a oo Wate
106. y control function for power failure 77 Air Sweep Built in drain pump 25 30 36 48 60 76 96 Wireless remote control 7 3 9 0 10 6 14 0 16 0 22 4 28 0 Type with Type with 8 0 10 0 11 4 16 0 18 0 25 0 35 built in separately Function reception installed 25 000 30000 36 000 47 800 54 600 76 400 95 500 part reception 27 000 34 000 39 000 54 600 61 500 85 300 107 500 part e OPERATION 4 KA BAF rs Maid a WIDE 9 X PNR XD484GHAB PNR XD484GHAB PNR XD484GHAB PNR XD484GHAB Ld 2 DF e e OPERATION 4 KA SHAE SPW SR254GXH56B R o WIDE f sw Panel pt PNR S253GHANB za bd 2 55 e amp OPERATION 4 Ed 2 SPW LDR254GXH56B TT 7 9 PNR LD254GHAB Ld 7 DE v b SPW U255XH SPW U365XH SPW U485XH SPW U605XH E U E DRY E4 T SPW U255SXHT SPW U305SXHT SPW U365SXHT SPW U485SXHT SPW U605SXHT e E E te DP woe rg E4 FE 1 HE 7 ee Ed T SPW SPW SPW SPW SPW FT rj f DR254GXH56B DR364GXH5
107. yout and indoor unit s location e Calculated data is stored with CSV type file 1 e Data of last 365 days is stored ren Li z e Each unit can be controlled by virtual remote controller on the display e Max 4 layout screens are shown at once STAIMS optional software TECS 5000B for BACnet interface Connectable to BMS system STAIMS optional software TECS 5000W for Web application Web access amp control from remote station eCan communicate with other EEG j equipment by BACnet protocol e SANYO air conditioners system can be i Ra controlled by both BMS and STAIMS eee e Max 256 indoor units be connected 1 PC that has STAIMS basic amp BACnet software e Accessing STAIMS software from remote PC e You can monitor operate SANYO system by using Web browser Internet Explorer STAIMS is suitable for large shopping centers and universities with many areas buildings 1 STAIMS PC can have 4 independent systems at once Each system can have max 8 C A units and control max 512 units In total 1024 indoor units can be controlled by 1 STAIMS PC Building A User PC Communication Adaptor Building B e Wiring length PC C A Max 1 km Max 8 C A for 1 system e Wiring length for each link from C A Max 1 km Communication Adaptor I C
108. ype X type T L A type Remote control by main remote controller RCS XM18BG WL RCS SH80BG WL RCS TRP80BG WL and sub controller is possible 2 remote controller main remote controller and sub controller can be installed for one indoor unit Do not perform group control for 3 Series indoor unit and 4 Series indoor unit together When RCS BH80BG WL is used wireless control becomes possible for all indoor units O When a separate receiver is set up in a different room control from that room also becomes possible OAutomatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted eln addition there are other functions like K type S type For all indoor units temperature setting operation switching wind RCS SH1BG RCS SS80BG WL RCS BH80BG WL direction fan speed setting etc 59 Simplified remote controller RCS KR1AGB Dimensions H 120 x W 70 x D 16 mm A remote controller with simple functions and basic operation Suitable for open rooms or hotels where detailed functions are not required O ON OFF operation mode switching temperature setting wind velocity switching wind direction setting alarm display and remote controller self diagnosis can be performed Batch group control for up to 8 indoor units Remote control by main remote controller and