Home
Sanyo KS1271 User's Manual
Contents
1. 16 Setting the Timer 17 Using the 1 Hour OFF Timer 19 Tips for Energy Saving 19 Adjusting the Airflow Direction 20 Operation without the Remote Control Unit 21 Care and Cleaning 21 Troubleshooting 24 Operating Range 24 Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ Dealer s address ________________________________________________ Phone number ________________ Alert Symbols The following symbols used in this manual alert you to
2. 3 Installation Location 4 Electrical Requirements 4 Safety Instructions 4 Names of Parts 5 Using the Remote Control Unit 10 Operation with the Remote Control Unit 12 1 Operation 12 2 Adjusting the Fan Speed 13 3 Fan Only 13 4 Night Setback Mode 14 5 QUIET Mode 15 6 HIGH POWER Mode 15 7 ION Mode 15 Special Remarks
3. Indication d angle du volet Indication de balayage d air 8 Mode de fonctionnement haute puissance 9 Fonctionnement silencieux 10 Fonctionnement d ionisation Affich lors du r glage du temporisateur Affich lors de la transmission de donn es Affich lorsque le capteur de l l ment int rieur est actif Affich lors du r glage de temp rature Affich quand la temp rature est indiqu e Affich uniquement lorsque l heure est r gl e sur l horloge de 12 heures Symboles 02_KS0971_FR fm Page 31 Monday October 17 2005 7 46 PM 32 T l commande L illustration ci dessus montre la t l commande lorsque le couvercle est ouvert metteur Quand on appuie sur les boutons de la t l commande le voyant appara t sur l afficheur pour signaler la transmission des r glages au r cepteur du climatiseur Capteur Le capteur de temp rature incorpor la t l commande d tecte la temp rature de la pi ce Afficheur Les informations sur le mode de fonctionnement s affichent lorsque la t l commande est allum e Si l appareil est hors tension les r glages FLAP Volet et FAN SPEED Vitesse de ventilateur ne sont pas affich s Bouton d ionisation ION Ce bouton permet d activer d sactiver la g n ration des ions n gatifs pendant le fonctionnement Bouton de
4. 1 Temporisateur 1 heure 1 HR TIMER Cette fonction fait en sorte que l appareil fonctionne pendant une heure puis qu il s arr te ind pendamment qu il soit en service ou hors service au moment o le bouton est actionn L indicateur de l afficheur indique que cette fonction est en service D marches de r glage Que l appareil soit en service ou l arr t appuyer sur le bouton de temporisateur 1 heure 1 HR TIMER L indicateur appara t sur l afficheur D marche d annulation Appuyer sur le bouton de marche arr t de fonctionnement ON OFF pour mettre l appareil hors service attendre qu il s arr te et appuyer une nouvelle fois sur le bouton de marche arr t de fonctionnement ON OFF La fonction de temporisation 1 heure est alors mise hors service et l appareil fonctionne normalement Pendant que fonctionne le temporisateur 1 heure si on appuie une fois sur le bouton de temporisateur 1 heure 1 HR TIMER afin de l annuler puis qu on y appuie nouveau l appareil continuera fonctionner pendant une heure partir de cet instant puis il s arr tera Il n est pas possible d utiliser ensemble le temporisateur d arr t et le temporisateur 1 heure La fonction programm e en dernier a priorit Si l on appuie sur le bouton de temporisateur 1 heure 1 HR TIMER alors que la fonction de temporisateur d arr t TIMER OFF est active le temporisateur d arr t
5. F WB 0 F DB OI 803 24 F 02_KS0971_FR fm Page 48 Monday October 17 2005 7 46 PM 49 02_KS0971_FR fm Page 49 Monday October 17 2005 7 46 PM SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 Plummer Street Chatsworth CA 91311 U S A In Canada SANYO Canada Inc 300 Applewood Crescent Concord Ontario L4K 5C7 Canada End fm Page 2 Thursday September 29 2005 3 55 PM
6. SANYO 2005 Pub OI 85264180803000 INSTRUCTION MANUAL MODE D EMPLOI Inverter Controlled Split System Air Conditioner Climatiseur de type s par contr l par inverseur Save These Instructions Conserver ce mode d emploi KS0971 KS1271 This air conditioner uses the new refrigerant R410A COOL DRY Model KS0971_Cover letter fm Page 2 Tuesday October 4 2005 3 55 PM 2 Features This air conditioner is an inverter type unit that automatically adjusts capacity as appropriate Details on these functions are provided below refer to these descriptions when using the air conditioner Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation easy logically displayed for easy use Simple One touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation 24 Hour ON or OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 24 hour period 1 Hour OFF Timer This timer can be set to automatically turn off the unit at any time after one hour Night Setback Pressing this button changes the setting of the room temperature thermostat allowing you to set the temperature at whatever level that you find comfortable Automatic and 3 step Fan Speed Auto High Medium Low Air Sweep Control This function
7. air dans la plage utilis e pendant le refroidissement ou le s chage COOL DRY FAN SWEEP REMARQUE ATTENTION OI 803 20 F 02_KS0971_FR fm Page 44 Monday October 17 2005 7 46 PM 45 Fonctionnement sans t l commande Entretien et nettoyage EL MENT INT RIEUR Si l on a gar la t l commande ou qu elle ne fonctionne pas correctement proc der comme suit Si le climatiseur ne fonctionne pas Chaque fois que ce bouton est appuy le mode de fonctionnement change de fa on cyclique La temp rature est r gl e sur 4 F en dessous de la temp rature ambiante pendant le refroidissement la vitesse et le volet du ventilateur sont r gl s sur Auto 1 Pour toute s curit teindre le climatiseur et le d brancher de la prise secteur 2 Ne pas verser d eau sur l l ment int rieur pour le nettoyer Cela pourrait ab mer les composants internes et provoquer des d charges lectriques Bo tier et grille l ment int rieur Nettoyer le bo tier et la grille de l l ment int rieur avec la brosse d un aspirateur ou les essuyer avec un chiffon propre et doux Si ces parties sont sales les nettoyer avec un chiffon propre humect d un d tergent liquide doux Quand on nettoie la grille faire attention de ne pas modifier la place des ailettes en frottant 1 Ne jamais utiliser de dissolvants ni de produits chimiques puissants Ne pas essuyer le bo tier en plastique avec de l eau tr
8. appareil Ce symbole signale un danger ou des op rations dangereuses qui risquent d entra ner des blessures physiques graves ou mortelles Ce symbole signale un danger ou des op rations dangereuses qui risquent d entra ner des blessures physiques ou des dommages mat riels notamment de l appareil AVERTISSEMENT ATTENTION OI 803 3 F 02_KS0971_FR fm Page 27 Monday October 17 2005 7 46 PM 28 Emplacement d installation Il est recommand de faire installer l appareil par un technicien qualifi et conform ment aux instructions fournies avec l appareil Avant de proc der l installation v rifier que la tension secteur du local d utilisation bureau ou habitation est la m me que celle indiqu e sur la plaque signal tique Instructions relatives l alimentation 1 Tous les c bles doivent respecter les codes lectriques locaux Pour les d tails consulter son magasin ou un lectricien qualifi 2 Chaque l ment doit tre correctement mis la terre avec un fil de terre ou de masse ou au moyen d un c blage d alimentation 3 Les raccordements devront tre confi s un lectricien qualifi Conseils de s curit Lire attentivement ce mode d emploi avant de faire fonctionner le climatiseur Si l on rencontre des difficult s ou des probl mes consulter son concessionnaire Le climatiseur est con u pour cr er un environnement confortable chez
9. 27 Emplacement d installation 28 Instructions relatives l alimentation 28 Conseils de s curit 28 Nom des pi ces 29 Utilisation de la t l commande 34 Fonctionnement avec t l commande 36 1 Fonctionnement 36 2 R glage de la vitesse du ventilateur 37 3 Ventilateur uniquement 37 4 Mode conomie nocturne 38 5 Mode de silencieux QUIET 39 6 Mode de fonctionnement haute puissance HIGH POWER 39 7 Mode d ionisation ION 39 Remarques sp ciales 40 R glage du temporisateu
10. 4 17 PM 10 Remote Control Unit continued Using the Remote Control Unit SENSOR button When you press this button use a small tipped object such as a ballpoint pen the mark will appear at the display And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly If the remote control is located near a heat source such as a space heater or in direct sunlight press the SENSOR button to switch to the sensor on the indoor unit Temperature Display Selector button This switches the temperature display between C and F Time Display Selector button This switches the time display between 24 hour time and 12 hour time ACL button ALL CLEAR Puts the remote control unit into pre operation status Always press this button after replacing the batteries ADDRESS switch The address switch changes to prevent mixing of signals from remote control units when two air conditioners are installed next to each other Normally the address switch is set to A For more information please contact the dealer where you made the purchase Normally the tabs on the remote control unit should not be bent The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble the air conditi
11. B Setting the airflow manually Referring to the above illustration use the FLAP button to set the airflow direction within the range used during the cooling or dehumidifying operation COOL DRY FAN SWEEP NOTE CAUTION OI 803 20 EG 01_KS0971_En fm Page 20 Monday October 17 2005 4 17 PM 21 Operation without the Remote Control Unit Care and Cleaning INDOOR UNIT If you have lost the remote control unit or it has trouble follow the steps below When the air conditioner is not running Each time the OPERATION button is pressed the operation mode changes cyclically The temperature is set to the room temperature minus 4 F during the cooling operation and the fan speed and flap are set to Auto 1 For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning 2 Do not pour water on the indoor unit to clean it This will damage the internal components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the indoor unit with a vacuum cleaner brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with a mild liquid detergent When cleaning the grille be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe the plastic casing using very hot water 2 Some metal edges and the fins are sharp and may cause inj
12. INT RIEUR Arriv e d air T l commande Sortie d air Tuyaux de fluide frigorig ne Tube de vidange L MENT EXT RIEUR Sortie d air REMARQUE OI 803 5 F 02_KS0971_FR fm Page 29 Monday October 17 2005 7 46 PM 30 Afficheur de l appareil et bouton de fonctionnement R cepteur de t l commande Cette section capte les signaux infrarouges envoy s par la t l commande metteur Bouton de fonctionnement OPERATION Lorsque la t l commande ne peut pas tre utilis e appuyer sur ce bouton permet un refroidissement Chaque fois que ce bouton est appuy le mode de fonctionnement change de fa on cyclique Voyant de fonctionnement OPERATION Ce voyant s allume lorsque le syst me est en mode DRY S CHAGE orange COOL REFROIDISSEMENT vert et FAN VENTILATEUR vert Voyant de temporisateur TIMER Ce voyant s allume quand le syst me fonctionne avec le temporisateur Voyant de silencieux QUIET Ce voyant s allume pendant le fonctionnement en mode QUIET silencieux Voyant d ionisation ION Ce voyant s allume lorsque l appareil fonctionne en mode ION et que l l ment int rieur fonctionne Les voyants d affichage de l unit sont att nu s pendant le fonctionnement en mode economie nocturne NIGHT SETBACK QUIET R cepteur de t l commande viter d utiliser un quipement radio tel qu un t l phone mobile pr s moins de 4 pieds
13. air afin d am liorer la circulation d air 2 Source de chaleur ou trop de monde dans la pi ce 2 Si possible liminer la source de chaleur 3 Portes et ou fen tres ouvertes 3 Les fermer pour emp cher la p n tration d air chaud 4 Obstacle devant l arriv e ou la sortie d air 4 Retirer l obstacle pour assurer une bonne circulation d air 5 Le thermostat est r gl sur une temp rature trop lev e pour le refroidissement 5 R gler la temp rature plus bas Le climatiseur produit un cliquetis A la suite d un changement de temp rature provoqu par refroidissement les pi ces en plastique de l appareil se r tr cissent ce qui provoque un l ger cliquetis C est normal et le son dispara tra apr s quelques instants Le voyant de fonctionnement OPERATION s allume mais l l ment ext rieur ne fonctionne pas 1 L emploi de t l phones cellulaires pr s du climatiseur peut perturber son fonctionnement normal 1 Couper l alimentation puis remettre le climatiseur en marche apr s un moment 2 Consulter le concessionnaire Temp rature Temp rature de l air int rieur Temp rature de l air ext rieur REFROIDISSEMENT Max 95 F DB 71 F WB 115 F DB Min 67 F DB 57 F WB 67 F DB Temp rature Temp rature de l air int rieur Temp rature de l air ext rieur REFROIDISSEMENT Max 95 F DB 71 F WB 115 F DB Min 67 F DB 57
14. e Appuyer sur le bouton pour r duire la temp rature r gl e Le r glage de la temp rature change de 1 C ou 2 F chaque fois qu un des boutons TEMP est enfonc Bouton de silencieux QUIET Lorsque vous appuyez sur ce bouton le ventilateur tourne plus lentement que la vitesse sur laquelle est r gl le ventilateur pour fournir un son de fonctionnement plus doux S lecteur de mode MODE Utiliser ce bouton pour s lectionner le mode DRY s chage COOL refroidissement ou FAN ventilateur DRY Le climatiseur r duit l humidit de la pi ce COOL Le climatiseur refroidit la pi ce FAN Le climatiseur fait office de ventilateur S lecteur de vitesse du ventilateur FAN SPEED Le climatiseur r gle automatiquement la vitesse du ventilateur Vitesse lev e Vitesse moyenne Vitesse faible Bouton d conomie nocturne NIGHT SETBACK Pour les d tails voir 4 Mode conomie nocturne Quand on appuie sur ce bouton en mode DRY s chage ou COOL refroidissement appara t sur l afficheur et la t l commande r gle automatiquement la temp rature de fa on conomiser l nergie Bouton de volet FLAP Appuyer sur ce bouton pour soit r gler la direction du flux d air sur Volet automatique dans chaque mode ou sur l une des six positions possibles manuellement soit pour s lectionner la fonction de balayage qui fait monter ou descendre le volet automatiquement R
15. e d air 2 Installer le filtre de nettoyage d air dans la position illustr e sur la figure 3 Remonter la grille d arriv e d air Nettoyage du filtre de nettoyage d air En g n ral il faut utiliser un aspirateur r gl faible puissance pour nettoyer le filtre une fois tous les trois mois Si le filtre est tr s encrass le tremper 1 ou 2 minutes dans une solution savonneuse ti de 1 partie de d tergent pour 500 parties d eau puis le laver Rincer le filtre l eau claire puis le laisser s cher la temp rature de la pi ce en le posant sur une serviette Ne pas plier le filtre de nettoyage d air ni appliquer une force excessive dessus Si la surface du filtre est tr s encrass e ou endommag e remplacer le filtre par un neuf Acheter un filtre de remplacement aupr s du concessionnaire local mod le STK FDXB Nettoyage de l appareil principale et de la t l commande Frotter avec un chiffon doux et sec Pour enlever les souillures tenaces tremper le chiffon dans de l eau pas plus chaude que 104 F tordre fortement le linge et frotter La grille d arriv d air peut tre enlev e pour la nettoyer l eau D pose et remise en place de la grille d arriv e d air Voir la section Retrait du filtre anti moisissure et Remplacement du filtre anti moisissure en page 46 A l emploi d un tabouret ou d un escabeau faire attention c
16. lamp This lamp lights during operation in the QUIET mode ION lamp This lamp lights during operation in the ION mode while the indoor unit is operating The unit s display lamps are dimmed during operation in the NIGHT SETBACK mode QUIET REMOTE CONTROL receiver Avoid using radio equipment such as mobile phone near within 4 ft the remote control receiver Some radio equipment may cause malfunction of the unit If the trouble happens disconnect power and restart the air conditioner after a few minutes IMPORTANT OPERATION lamp TIMER lamp QUIET lamp OPERATION button INDOOR UNIT ION lamp Cooling operation Stop NOTE OI 803 6 EG 01_KS0971_En fm Page 6 Monday October 17 2005 4 17 PM 7 Remote Control Unit Display 1 Operation mode MILD DRY COOL FAN 2 Fan speed Automatic operation HIGH MEDIUM LOW 3 Temperature setting 60 86 F When set to 80 F temperature indication 4 Timer 24 hour clock with ON OFF program Timer ON Timer OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirma
17. potentially dangerous conditions to users service personnel or the appliance This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage CAUTION OI 803 3 EG 01_KS0971_En fm Page 3 Monday October 17 2005 4 17 PM 4 Installation Location We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit Before installation check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate Electrical Requirements 1 All wiring must conform to the local electrical codes Consult your dealer or a qualified electrician for details 2 Each unit must be properly grounded with a ground or earth wire or through the supply wiring 3 Wiring must be done by a qualified electrician Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual Do not install this air conditioner where there are fumes or flammable gases or in an
18. s chaude 2 Certains bords m talliques et les ailettes tant coupants ils doivent tre manipul s avec pr caution lors du nettoyage sous peine de provoquer des blessures 3 La bobine interne et les autres composants de l l ment ext rieur doivent tre nettoy s tous les ans Consulter le concessionnaire ou un service apr s vente Bouton de fonctionnement OPERATION Refroidissement Arr t REMARQUE AVERTISSEMENT ATTENTION OI 803 21 F 02_KS0971_FR fm Page 45 Monday October 17 2005 7 46 PM 46 Entretien et nettoyage suite Filtre anti moisissure Le filtre anti moisissure situ derri re la grille d arriv e d air doit tre v rifi et nettoy au moins une fois toutes les deux semaines Retrait du filtre anti moisissure 1 Saisir les deux bords de la grille d arriv e d air et retirer la en tirant vers vous 2 Retirer le filtre anti moisissure attach l arri re de la grille d arriv e d air Nettoyage Se servir d un aspirateur pour enlever la poussi re l g re Si de la poussi re adh re au filtre laver celui ci dans de l eau ti de et savonneuse puis le rincer dans de l eau propre et le s cher Remplacement du filtre anti moisissure 1 Alors que la marque FRONT du filtre anti moisissure est situ e l avant aligner les deux encoches pr s de la marque avec les crochets l arri re de la grille d arriv e d air puis monter le filtre anti moisissu
19. soi Ne l utiliser qu aux fins pour lesquelles il a t pr vu en suivant les instructions de ce manuel Ne pas installer le climatiseur dans un endroit o existent des manations gazeuses ou des gaz inflammables ou dans un endroit tr s humide comme une serre Ne pas installer le climatiseur o se trouvent des objets d gageant une tr s forte chaleur viter Pour prot ger le climatiseur de toute corrosion viter d installer l l ment ext rieur dans un endroit qui risque d tre asperg d eau de mer ou dans un environnement sulfureux par exemple proximit d une source thermale Ne jamais utiliser ni entreposer d essence ni aucune autre vapeur ou liquides inflammables pr s du climatiseur cela serait extr mement dangereux Le climatiseur ne poss de pas de ventilateur d admission d air frais ext rieur Il faudra donc ouvrir fr quemment les portes ou les fen tres si l on utilise dans la m me pi ce des appareils de chauffage gaz ou au mazout qui consomment beaucoup d oxyg ne Sinon il y aurait risque d asphyxie dans les cas extr mes Ne pas mettre le climatiseur sous et hors tension en le branchant et en le d branchant Utiliser le bouton de marche arr t de fonctionnement ON OFF Ne rien introduire dans la sortie d air de l l ment ext rieur Cela est tr s dangereux car le ventilateur marche grande vitesse Ne pas laisser les enfa
20. suivants sont utilis s pour le bouton de s lection de l affichage de temp rature et d heure sur la partie avant inf rieure de la t l commande Temp rature F Heure AM PM 1 R glage l heure actuelle Exemple pour r gler l horloge 10 30 p m 2 R glage du moment de mise l arr t OFF Exemple pour programmer l arr t du climatiseur 11 00 a m REMARQUE D marche Affichage 1 Appuyer sur ce bouton de l horloge CLOCK si l indicateur de l heure ne clignote pas Seule l affichage de l heure clignote 2 Appuyer sur les boutons Suivant et Pr c dent jusqu ce que PM 10 30 apparaisse L heure peut tre r gl e en incr ments de 1 minute Si vous maintenez le bouton enfonc l heure change rapidement en incr ments de 10 minutes 3 Appuyer nouveau sur le bouton de l horloge CLOCK Ceci ach ve le r glage de l heure actuelle 1 Appuyer sur le bouton de r glage de l heure d arr t OFF TIME L indicateur du temporisateur appara t et l heure d arr t OFF actuelle est affich e 2 Appuyer sur les boutons Suivant et Pr c dent jusqu ce que AM 11 00 apparaisse L indicateur du temporisateur clignote L heure peut tre r gl e en incr ments de 10 minutes Si vous maintenez le bouton enfonc l heure change rapidement en incr ments de 10 minutes 3 Patienter quelques secondes pour
21. unit may be operated either from a non fixed position or from a wall mounted position To ensure that the air conditioner operates correctly DO NOT install the remote control unit in the following places DO NOT In direct sunlight Behind a curtain or other places where it is covered More than 26 feet 8 m away from the air conditioner In the path of the air conditioner s airstream Where it may become extremely hot or cold Where it may be subject to electrical or magnetic noise Where there is an obstacle between the remote control unit and air conditioner since a check signal is sent from the remote control unit every 5 minutes Mounting the Remote Control Unit Before mounting the remote control unit press the ON OFF operation button at the mounting location to make sure that the air conditioner operates from that location The indoor unit should make a beeping sound to indicate that it has received the signal To take out the remote control unit pull it forward When Holding the Remote Control Unit When using the remote control unit and during air conditioner operation the transmitter on the remote control unit should be pointed toward the receiver on the indoor unit Make sure that there are no objects between the remote control unit and receiver which could block the signal Air conditioner Indoor unit Receiver Remote control unit Transmitter head Remote control unit mou
22. vers le r cepteur de l l ment int rieur S assurer qu aucun objet susceptible de bloquer le signal ne se trouve entre le r cepteur et la t l commande Climatiseur l ment int rieur R cepteur T l commande T te de l metteur Bo tier de la t l commande Vis de montage 5 32 x 5 8 4 x 16 mm fournies Partie arri re Trou Pour emp cher la perte de la t l commande vous pouvez connecter celle ci au bo tier en passant une ficelle travers la t l commande et travers le trou d attachement Appuyer Mis en place OI 803 11 F 02_KS0971_FR fm Page 35 Monday October 17 2005 7 46 PM 36 Fonctionnement avec t l commande 1 Fonctionnement V rifier que le disjoncteur se trouvant sur le panneau de contr le lectrique est en position de marche Appuyer sur les boutons comme expliqu ci dessous et changer les r glages selon les besoins TAPE 1 Appuyer sur le s lecteur de mode MODE et choisir le mode souhait Pour le s chage Pour le refroidissement Pour la ventilation seulement TAPE 2 Pour mettre le climatiseur en marche appuyer sur le bouton de marche arr t de fonctionnement ON OFF TAPE 3 Appuyer sur les boutons de r glage de la temp rature TEMP pour changer le r glage de la temp rature la valeur souhait e Plage des temp ratures r glables TAPE 4 R gler le s lecteur du vitesse de ventilation FAN SPE
23. will restart automatically within five minutes by the remote control unit Clicking sound is heard from the air conditioner In cooling operation any plastic parts may shrink due to a sudden temperature change In this event a clicking sound may occur This is normal and the sound will soon disappear The remote control unit sends the setting condition to the air conditioner regularly at five minute intervals DRY Operation Cooling Operation Power failure during operation Clicking Sound Remote Control Unit OI 803 16 EG 01_KS0971_En fm Page 16 Monday October 17 2005 4 17 PM 17 Setting the Timer In the descriptions below the following settings are used for the temperature and time indicator selector button on the bottom front section of the remote control Temperature F Time AM PM 1 How to set the present time Example To set to 10 30 pm 2 How to set the OFF time Example To stop the air conditioner at 11 00 am NOTE Operation Indication 1 Press the CLOCK button once if the time indicator is not flashing The time indication alone flashes 2 Press the Advance Return button until PM 10 30 is displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CLOCK button again This completes the setting of the current time 1 Press the OFF TIME settin
24. ED la valeur souhait e TAPE 5 Appuyer sur le bouton de volet FLAP et ajuster la direction du flux d air selon ses pr f rences Voir R glage du flux d air en page 44 Pour arr ter le climatiseur appuyer nouveau sur le bouton de marche arr t de fonctionnement ON OFF TAPE 2 TAPE 1 TAPE 3 TAPE 4 TAPE 5 REMARQUE 30 C max 16 C min ou 86 F max 60 F min OI 803 12 F 02_KS0971_FR fm Page 36 Monday October 17 2005 7 46 PM 37 Fonctionnement avec t l commande suite Rechercher le meilleur emplacement possible dans la pi ce pour la t l commande qui fait galement fonction de d tecteur de confort et qui transmet les instructions de fonctionnement Une fois que l on a trouv l emplacement id al y laisser la t l commande en permanence L appareil poss de un circuit retardement incorpor de 5 minutes afin de garantir un fonctionnement en toute s curit Quand on appuie sur le bouton de fonctionnement le compresseur ne commencera fonctionner que 3 minutes plus tard En cas d une panne de courant l appareil s arr te 2 R glage de la vitesse du ventilateur A Vitesse automatique du ventilateur Il suffit de mettre le s lecteur de vitesse du ventilateur FAN SPEED sur la position Elle r gle automatiquement la meilleure vitesse du ventilateur pour la temp rature de la pi ce B Vitesse manuelle du vent
25. Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set too high for cooling 5 Set the temperature lower Clicking sound is heard from the air conditioner In cooling operation any plastic parts may shrink due to a sudden temperature change In this event a clicking sound may occur This is normal and the sound will soon disappear OPERATION lamp lights but outdoor unit will not run 1 The use of cellular phones near the air conditioner may cause disturbance to its normal operation 1 Turn off the power then restart the air conditioner after a while 2 Consult your dealer Temperature Indoor air temperature Outdoor air temperature COOLING Max 95 F DB 71 F WB 115 F DB Min 67 F DB 57 F WB 67 F DB Temperature Indoor air temperature Outdoor air temperature COOLING Max 95 F DB 71 F WB 115 F DB Min 67 F DB 57 F WB 0 F DB OI 803 24 EG 01_KS0971_En fm Page 24 Monday October 17 2005 4 17 PM 25 01_KS0971_En fm Page 25 Monday October 17 2005 4 17 PM 26 Caract ristiques Ce climatiseur est un syst me de type inverseur qui ajuste automatiquement la capacit en fonction des besoins Des d tails sur ces fonctions sont fournis ci dessous se r f rer ces descriptions lors de l utilisation
26. ac es fond vers la gauche ou la droite une condensation risque de se produire autour de la sortie d air et de s goutter 2 Verticalement Le flux vertical de l air peut se r gler en d pla ant le volet l aide de la t l commande Ne pas d placer ce volet de la main V rifier que la t l commande est allum e et se servir du bouton de volet FLAP pour r gler le volet sur la fonction de balayage ou sur une des six positions du flux d air Le volet se referme automatiquement quand l appareil est mis hors tension Utiliser bouton de volet FLAP de la t l commande pour ajuster la position du volet Si l on d place le volet de la main il y aura un d calage entre la position r gl e par la t l commande et la position r elle Dans ce cas mettre l appareil hors tension attendre que le volet se referme puis remettre l appareil sous tension La position du volet sera nouveau normale Ne pas diriger le volet vers le bas pendant le refroidissement car une condensation risque de se produire autour de la sortie d air et de s goutter ATTENTION A Balayage Le volet commence se d placer de haut en bas pour fournir l air dans la plage de balayage C Fonction de volet automatique Le volet est r gl sur la position recommand e B R glage manuel du flux d air En observant l illustration ci dessus se servir du bouton de volet FLAP pour r gler la direction du flux d
27. ande Quand on utilise la t l commande toujours diriger la t te de l metteur droit sur le r cepteur du climatiseur Emplacement d installation de la t l commande La t l commande pourra tre utilis e en position mobile ou en position fixe montage mural Pour garantir un bon fonctionnement du climatiseur NE PAS installer la t l commande dans les endroits suivants NE PAS En plein soleil Derri re un rideau ou tout autre endroit o elle serait cach e plus de 26 pieds 8 m tres du climatiseur Sur le trajet du flux d air du climatiseur Dans un endroit qui risque de devenir extr mement chaud ou froid Dans un endroit soumis des parasites lectriques ou magn tiques L o un obstacle s interpose entre la t l commande et le climatiseur en effet un signal de v rification est envoy par la t l commande toutes les 5 minutes Installation de la t l commande Avant de monter la t l commande appuyer sur le bouton de marche arr t de fonctionnement ON OFF l endroit du montage pour s assurer que le climatiseur pourra fonctionner partir de cet endroit L l ment int rieur devrait mettre un bip sonore pour indiquer qu elle a re u le signal Pour retirer la t l commande tirer vers l avant Manipulation de la t l commande Lors de l utilisation de la t l commande et du climatiseur l metteur de la t l commande devrait tre point
28. ctober 17 2005 4 17 PM 20 Adjusting the Airflow Direction 1 Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right When the humidity is high the vertical vanes should be in the front position during the cooling or dehumidifying operation If the vertical vanes are positioned all of the way to the right or left condensation may begin to form around the air vent and drip down 2 Vertical The vertical airflow can be adjusted by moving the flap with the remote control unit Do not move the flap with your hands Confirm that the remote control unit has been turned on Use the FLAP button to set either the sweep function or one of the six airflow direction settings The flap automatically closes when the unit is off Use the FLAP button on the remote control to adjust the position of the flap If you move the flap by hand the flap position according to the remote control and the actual flap position may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not have the flap pointed down during cooling operation Condensation may begin to form around the air vent and drip down CAUTION A Sweep function The flap starts moving up and down to deliver air over the sweep range C Auto flap function The flap is set to the recommended position
29. d the negative ion generator is left to build up a puffing or sputtering sound will eventually be heard In this case clean the generator immediately Do not apply excessive force while performing maintenance Air clean filter NOTE CAUTION Negative ion generator metal electrodes inside plastic case NOTE OI 803 23 EG 01_KS0971_En fm Page 23 Monday October 17 2005 4 17 PM 24 Troubleshooting If your air conditioner does not work properly first check the following points before requesting service If it still does not work properly contact your dealer or service center Operating Range The air conditioner is operable within the temperature ranges as listed below For Cooling Only Models C0971 C1271 For Low Ambient Cooling Models CL0971 CL1271 Trouble Possible Cause Remedy Air conditioner does not run at all 1 Power failure 1 Restore power 2 Leakage circuit breaker tripped 2 Contact service center 3 Line voltage is too low 3 Consult your electrician or dealer 4 Batteries in remote control unit have run down 4 Replace batteries OPERATION lamp blinks and air conditioner does not operate Trouble in system Contact service center Compressor runs but soon stops Obstruction in front of condenser coil Remove obstruction Poor cooling performance 1 Dirty or clogged air filter 1 Clean air filter to improve airflow 2 Heat source or many people in room 2
30. dless of whether the unit is operating or stopping the unit operates for one hour and then shuts down Transmitter Sensor Cover closed Display FAN SPEED selector button FLAP button ON TIME setting buttons Return button Advance button CANCEL button SENSOR button CLOCK button ACL button ON OFF operation button 1 HR TIMER button Temperature setting buttons TEMP MODE selector button Advance button NIGHT SETBACK button HIGH POWER button OFF TIME setting buttons Return button ION button ADDRESS switch Temperature display selector button Time display selector button QUIET button NOTE OI 803 8 EG 01_KS0971_En fm Page 8 Monday October 17 2005 4 17 PM 9 Remote Control Unit continued Temperature setting buttons TEMP Press the button to increase the set temperature Press the button to reduce the set temperature The temperature setting changes by 1 C or 2 F each time one of the TEMP buttons is pressed QUIET button When you press this button the fan rotates slower than the fan speed setting to provide a quieter operating sound MODE selector button Use this button to select DRY COOL or FAN mode DRY The air conditioner reduces the humidity in the room COOL The air conditioner makes the room cooler FAN The air conditioner works only as a circulation fan FAN SPEED selector button The air conditioner automatically decides t
31. du r cepteur de t l commande Cela pourrait causer un mauvais fonctionnement de l appareil Si une d faillance se produit d brancher l appareil et le remettre en service apr s quelques minutes IMPORTANT Voyant de fonctionnement OPERATION Voyant de temporisateur Bouton de fonctionnement OPERATION L MENT INT RIEUR Voyant de temporisateur TIMER Voyant d ionisation ION Voyant de silencieux QUIET Refroidissement Arr t REMARQUE OI 803 6 F 02_KS0971_FR fm Page 30 Monday October 17 2005 7 46 PM 31 OI 803 7 F T l commande Affichage 1 Mode de fonctionnement MILD DRY s chage COOL refroidissement FAN ventilation 2 Vitesse de ventilation Fonctionnement automatique Vitesse lev e Vitesse moyenne Vitesse faible 3 R glage de la temp rature 60 86 F Indication lors d un r glage de temp rature de 80 F 4 Temporisateur Horloge affichage sur 24 heures avec programmateur de marche arr t Programmation de la mise en marche ON Programmation de l arr t OFF Temporisateur 1 heure 5 Mode d conomie nocturne 6 Confirmation de transmission 7 Volet automatique
32. du climatiseur Fonctionnement contr l par microprocesseur Le logement interne de la t l commande procure diverses fonctions qui facilitent le fonctionnement automatique et elles sont clairement affich es pour simplifier les d marches Simplificit d une t l commande infrarouge Cette t l commande comporte plusieurs atouts qui facilitent le fonctionnement automatique Marche arr t par temporisateur sur 24 heures Ce temporisateur peut tre programm pour commander automatiquement la mise en marche et l arr t tout moment pendant une p riode de 24 heures Temporisateur 1 heure Ce temporisateur peut tre programm pour commander automatiquement la mise l arr t apr s une heure de fonctionnement Economie nocturne Une pouss e sur ce bouton change le r glage du thermostat et permet d ajuster la temp rature au niveau jug le plus confortable Vitesse de ventilation automatique et 3 paliers Choix entre Automatique Vitesse lev e moyenne et faible Contr le du balayage d air Cette fonction d place un volet dans la sortie d air vers le haut et le bas afin de diriger l air dans toute la pi ce selon un mouvement de balayage et assurer ainsi le confort dans chaque coin Commande de volet automatique Elle r gle automatiquement le volet sur la position optimum pendant le refroidissement et le s chage Fonction de remise en marche automatiq
33. e le bouton de haute puissance HIGH POWER est activ l unit op re sortie maximale pendant 30 minutes ind pendamment de la temp rature d sir e La vitesse du ventilateur est un palier sup rieur lev e Les modes de silencieux QUIET et de fonctionnement haute puissance HIGH POWER ne peuvent pas tre utilis s en m me temps 7 Mode d ionisation ION Le mode d ionisation ION est utilis pendant le fonctionnement pour g n rer des ions n gatifs qui rafra chissent l air dans la pi ce Appuyez sur le bouton d ionisation ION appara t sur l afficheur Pour annuler appuyez de nouveau sur le bouton d ionisation ION Le voyant d ionisation ION de l l ment int rieur s allume lorsque des ions n gatifs sont g n r s Le mode d ionisation ION est activ par d faut sur la l unit de tel commande Les ions n gatifs sont g n r s par le g n rateur d ions n gatifs En fonction des conditions de fonctionnement la vitesse du ventilateur peut tre l g rement acc l r e uniquement REMARQUE OI 803 15 F 02_KS0971_FR fm Page 39 Monday October 17 2005 7 46 PM 40 Remarques sp ciales Comment agit il Une fois que la temp rature de la salle atteint le niveau r gl la vitesse de fonctionnement de l unit est modifi e automatiquement Pendant le s chage la vitesse du ventilateur est r gl e automatiquement
34. e qu il ne se renverse pas Nettoyage de la grille l eau Nettoyer la grille d licatement avec une ponge douce par exemple et enlever ensuite toute trace d humidit L emploi d un d tergent neutre n est pas interdit pour enlever les souillures tenaces Rincer ensuite convenablement avec de l eau et essuyer toute trace d humidit Nettoyage du g n rateur d ions n gatifs Si le g n rateur est sale suivez la proc dure ci dessous Pour toute s curit teindre le climatiseur et le d brancher de la prise secteur avant de nettoyer Nettoyez la poussi re sur le g n rateur d ions n gatifs Utilisez une brosse dents etc pour d poussi rer l extr mit Utilisez un cotton tige pour nettoyer autour du g n rateur l int rieur du bo tier en plastique en vitant de toucher les lectrodes Le g n rateur d ions n gatifs et d autres pi ces m talliques peuvent se d colorer lorsqu ils sont utilis s Cette d coloration est normale et n indique pas un mauvais fonctionnement Si la salet s accumule sur et dans le g n rateur d ions n gatifs un son ressemblant un toussotement risque de se faire entendre Si cela se produit nettoyez le g n rateur sans attendre N appliquez pas une force excessive lors de l entretien AVERTISSEMENT Filtre de nettoyage d air REMARQUE ATTENTION G n rateur d ions n gatifs lectrode
35. eplace it with new one Purchase a replacement filter at your local dealer model STK FDXB Cleaning the main unit and remote control unit Wipe clean using a soft dry cloth To remove stubborn dirt moisten a cloth in warm water no hotter than 104 F wring thoroughly and then wipe The air intake grille can be removed in order to wash it with water Removing and remounting the air intake grille Refer to How to remove the anti mold filter and How to replace the anti mold filter on page 22 When using a footstool or the like be careful not to let it tip over Washing the grille with water Clean the grille gently using a soft sponge or the like Then wipe away any remaining moisture Neutral detergent may be used to remove stubborn dirt Then rinse thoroughly with water and wipe away any remaining moisture Cleaning the negative ion generator Follow the steps below when the generator has become dirty For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning Remove the dust on the negative ion generator Use a toothbrush etc to dust off the end Use a cotton swab etc to clean around the generator inside the plastic case taking care not to touch the electrodes During use the negative ion generator and other metal parts may become discolored this is normal and not indicative of malfunctioning If the dirt on and aroun
36. er with the remote control unit Air Intake Air from the room is drawn into this section and passes through air filters which remove dust Air Outlet Conditioned air is blown out of the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and air sweeping Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Drain Hose Moisture in the room condenses and drains off through this hose Outdoor Condensing Unit The outdoor unit contains the compressor fan motor heat exchanger coil and other electrical components INDOOR UNIT Air intakes Remote control unit Air outlet Refrigerant tubes Drain hose OUTDOOR UNIT Air outlet NOTE OI 803 5 EG 01_KS0971_En fm Page 5 Monday October 17 2005 4 17 PM 6 Unit Display and Operation Button REMOTE CONTROL receiver This section picks up infrared signals from the remote control unit transmitter OPERATION button When the remote control cannot be used pressing this button enables cooling operation Each time this button is pressed the operation mode changes cyclically OPERATION lamp This lamp lights when the system is in the continuous DRY orange COOL green and FAN green mode TIMER lamp This lamp lights when the system is being controlled by the timer QUIET
37. esired temperature The fan speed is 1 step above High QUIET Mode and HIGH POWER Mode cannot be used at the same time 7 ION Mode The ION mode is used during operation to generate negative ions that freshen up the air in the room Press the ION button The mark appears in the display To cancel press ION button again The indoor unit s ION lamp lights up while negative ions are being generated ION on is the remote control unit s initial setting The negative ions are generated from the negative ion generator Depending on the operating conditions the fan speed may be increased by a small amount only NOTE OI 803 15 EG 01_KS0971_En fm Page 15 Monday October 17 2005 4 17 PM 16 Special Remarks How it works Once the room temperature reaches the level that was set the unit s operation frequency is changed automatically During DRY operation the fan speed automatically runs at lower speed for providing a comfortable breeze DRY operation is not possible if the indoor temperature is 59 F or less Sometimes the indoor unit may not get to the set fan speed such as LOW and QUIET under cool operation at very low outdoor temperatures due to the indoor unit being protected from ice or frost when combined with the outdoor unit for Low Ambient Cooling models In the event of power failure the unit will stop When the power is resumed the unit
38. est d sactiv et le climatiseur s arr te de fonctionner une heure plus tard 2 Fonctionnement combin avec le temporisateur de mise en marche arr t quotidienne DAILY ON OFF REPEAT Le r glage du temporisateur 1 heure 1 HR TIMER a priorit sur le r glage de programme quotidien Choses ne pas faire Obstruer les arriv es et les sorties d air de l appareil Si elles sont bouch es l appareil ne fonctionnera pas de fa on satisfaisante et il risque d tre endommag Laisser le soleil p n trer plein dans la pi ce Utiliser des persiennes ou des rideaux Si les murs et le plafond de la pi ce sont chauds sous l action du soleil il faudra plus longtemps pour refroidir la pi ce Choses faire Toujours maintenir le filtre air propre Voir la section Entretien et nettoyage Un filtre colmat amoindrira les performances de l appareil Pour viter que l air r frig r ne s chappe maintenir toutes les fen tres portes et autres ouvertures ferm es REMARQUE OI 803 19 F 02_KS0971_FR fm Page 43 Monday October 17 2005 7 46 PM 44 R glage du flux d air 1 Horizontalement Le flux horizontal de l air se r gle en d pla ant avec les mains les ailettes verticales vers la gauche ou vers la droite Lorsque l humidit est lev e les ailettes verticales doivent se trouver la position avant pendant le refroidissement ou le s chage Si elles sont pl
39. extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generating objects are placed Avoid To protect the air conditioner from heavy corrosion avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa Never use or store gasoline or other flammable vapor or liquid near the air conditioner it is very dangerous This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or oil heating appliances in the same room which consume a lot of oxygen from the air Otherwise there is a risk of suffocation in an extreme case Do not turn the air conditioner on and off from the power mains switch Use the ON OFF operation button Do not stick anything into the air outlet of the outdoor unit This is dangerous because the fan is rotating at high speed Do not let children play with the air conditioner Do not cool the room too much if babies or invalids are present CAUTION OI 803 4 EG 01_KS0971_En fm Page 4 Monday October 17 2005 4 17 PM 5 Names of Parts This illustration is based on the external view of a standard model Consequently the shape may differ from that of the air conditioner which you have selected This air conditioner consists of an indoor unit and an outdoor unit You can control the air condition
40. g button once The timer indication is displayed and the present OFF time is shown 2 Press the Advance Return button until AM 11 00 is displayed The timer indication blinks The time can be set in 10 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Wait a few seconds and then the setting is complete The timer indication stops blinking and the present time is displayed OI 803 17 EG 01_KS0971_En fm Page 17 Monday October 17 2005 4 17 PM 18 Setting the Timer continued 3 How to set the ON time Example To start operation at 7 10 am 4 How to set DAILY ON OFF REPEAT timer Example To start operation at 7 10 am and stop the air conditioner at 11 00 am To cancel a timer program Press the CANCEL button When either an ON or OFF timer is to be canceled press the button corresponding to the timer whose program is to be canceled and then press the CANCEL button The airflow direction fan speed and temperature setting can be changed after a timer program has been set even when the unit is stopped Even when operation is stopped during an ON timer program the unit will start operating when the set time is reached provided that the program is not canceled When the ON timer and OFF timer are set to the same time the timer operates as if it is turned off Operation Indication 1 Press the ON TIME setting button once The time
41. glage de volet automatique Si s lectionn durant le refroidissement ou le s chage le volet est r gl sur la position 7 dans l illustration suivante La direction du flux d air peut tre r gl e manuellement six positions Le volet se d place automatiquement vers le haut et vers le bas Lorsque vous appuyez sur le bouton de volet FLAP la direction du flux d air est modifi e comme suit Bouton de haute puissance HIGH POWER Si ce bouton est activ durant le fonctionnement en mode DRY s chage COOL refroidissement et FAN ventilateur l unit op re sortie maximale pendant 30 minutes ind pendamment de la temp rature d sir e La vitesse du ventilateur est un palier sup rieur lev e Boutons de r glage de l heure de mise en marche arr t ON TIME OFF TIME Aucun affichage Le temporisateur ne fonctionne pas Le climatiseur se met en marche l heure programm e Le climatiseur s arr te l heure programm e Le climatiseur s arr te et se met en marche ou se met en marche et s arr te chaque jour aux m mes heures Pour les d tails voir R glage du temporisateur REMARQUE Balayage OI 803 9 F 02_KS0971_FR fm Page 33 Monday October 17 2005 7 46 PM 34 T l commande suite Utilisation de la t l commande Bouton de capteur de climatiseur SENSOR Lorsqu on appuie sur ce bouton utiliser une pointe fine telle que stylo bille le p
42. he fan speeds High fan speed Medium fan speed Low fan speed NIGHT SETBACK button For details see 4 Night Setback Mode When you press this button in the DRY or COOL mode the mark appears in the display and the remote control unit will automatically adjust the set temperature to save energy FLAP button Press this button either to select the setting of the airflow direction to the auto flap in each mode or one of the six possible positions manually or to select the sweep function which moves the flap up and down automatically Auto flap setting If selected in a cooling or dry operation the flap is set at position 7 in the following chart The airflow direction can be set manually six positions The flap moves up and down automatically When you press the FLAP button the air flow direction will be changed one by one as follows HIGH POWER button If this button is pressed during DRY COOL or FAN operation the unit operates at maximum output for 30 minutes regardless of the desired temperature The fan speed is 1 step above High ON TIME OFF TIME setting buttons No display The timer does not operate The air conditioner starts at the set time The air conditioner stops at the set time The air conditioner stops and starts or starts and stops at the set times every day For details see Setting the Timer NOTE SWEEP OI 803 9 EG 01_KS0971_En fm Page 9 Monday October 17 2005
43. ictogramme s affiche La temp rature de la pi ce est alors d tect e par le capteur int gr l l ment int rieur et le climatiseur fonctionne selon les informations fournies par ce capteur Si la t l commande se trouve pr s d une source de chaleur telle qu un radiateur ou en plein soleil appuyer sur le bouton SENSOR pour que la d tection de temp rature soit effectu e par le capteur de l l ment int rieur Bouton de s lection de l affichage de la temp rature L affichage de la temp rature bascule entre C et F Bouton de s lection de l affichage de l heure L affichage de l heure bascule entre l horloge de 24 heures et l horloge de 12 heures Bouton de r initialisation ACL Elle ram ne la t l commande son tat original Appuyer sur ce bouton apr s le remplacement des piles Commutateur d adresse ADDRESS Le commutateur d adresse change pour emp cher le m lange des signaux provenant des t l commandes lorsque deux climatiseurs sont install s l un c t de l autre En principe le commutateur d adresse est r gl sur A Pour de plus amples informations contacter le revendeur o vous avez achet l appareil En principe les languettes de la t l commande ne sont pas pli es La t l commande envoie le signal de temp rature au climatiseur toutes les cinq minutes Si le climatiseur ne re oit pas de signal de la t l commande pendant plus de 15 m
44. ilateur Pour r gler la vitesse du ventilateur manuellement pendant le fonctionnement il suffit de mettre le s lecteur de vitesse du ventilateur FAN SPEED sur la position voulue ou 3 Ventilateur uniquement Pour faire circuler l air sans modifier la temp rature suivez la proc dure suivante TAPE 1 Appuyer sur le bouton de s lection du mode MODE pour passer en mode ventilateur TAPE 2 Appuyer sur le bouton de marche arr t de fonctionnement ON OFF TAPE 3 Appuyer sur le s lecteur de la vitesse du ventilateur FAN SPEED pour s lectionner la vitesse voulue ou REMARQUE TAPE 2 TAPE 1 TAPE 3 OI 803 13 F 02_KS0971_FR fm Page 37 Monday October 17 2005 7 46 PM 38 Fonctionnement avec t l commande suite 4 Mode conomie nocturne Ce mode permet de r duire la consommation d nergie Appuyer sur le bouton d conomie nocturne NIGHT SETBACK pendant le fonctionnement appara t sur l afficheur Pour lib rer la fonction d conomie nocturne appuyer nouveau sur le bouton d conomie nocturne NIGHT SETBACK En mode de refroidissement et s chage et Quand le mode d conomie nocturne est s lectionn le climatiseur l ve automatiquement de 2 F le r glage de la temp rature quand 30 minutes se sont coul es apr s que la s lection a t faite puis nouveau de 2 F apr s 30 minutes quelle que soit la temp rature in
45. inutes en raison d une d faillance de celle ci ou pour une autre raison il utilise le capteur de temp rature int gr l l ment int rieur pour r gler la temp rature de la pi ce Il se peut alors que la temp rature au niveau de la t l commande soit diff rente de la temp rature d tect e au niveau du climatiseur Installation des piles Les piles ont une autonomie de six mois environ en fonction de la fr quence d utilisation de la t l commande Remplacer les piles si le voyant de l affichage ne s allume plus ou si la t l commande ne permet plus de modifier les r glages du climatiseur Utiliser deux piles alcalines neuves et tanches de format AAA Pour le remplacement des piles suivre les instructions du paragraphe Installation des piles Si l on ne se sert pas de la t l commande pendant plus d un mois retirer les piles REMARQUE REMARQUE 1 Glisser le couvercle dans le sens indiqu par la fl che et le retirer 2 Ins rer deux piles alcalines de format AAA Bien v rifier que les piles sont install es suivant les rep res inscrits dans le logement des piles 3 A l aide d un objet comme la pointe d un crayon appuyer sur le bouton de r initialisation ACL Bouton de r initialisation ACL REMARQUE OI 803 10 F 02_KS0971_FR fm Page 34 Monday October 17 2005 7 46 PM 35 Utilisation de la t l commande suite Utilisation de la t l comm
46. ion press the NIGHT SETBACK button again In Cooling and DRY Mode and When the night setback mode is selected the air conditioner automatically raises the temperature setting 2 F when 30 minutes have passed after the selection was made and then another 2 F after another 30 minutes have passed regardless of the indoor temperature when night setback was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle cooling is needed Setting temperature Press the NIGHT SETBACK button 30 min 30 min Time 2 F 2 F OI 803 14 EG 01_KS0971_En fm Page 14 Monday October 17 2005 4 17 PM 15 Operation with the Remote Control Unit continued 5 QUIET Mode QUIET Mode is used to reduce the fan sound of the indoor unit Press the QUIET button The mark appears in the display To cancel press QUIET button again In QUIET Mode the fan rotates at a slower speed than the fan speed setting If the unit is already operating with a very low airflow the fan sound may not change even if the QUIET button is pressed 6 HIGH POWER Mode HIGH POWER mode can be used to increase the output of the indoor unit for all operation modes Press the HIGH POWER button The mark appears in the display To cancel press HIGH POWER button again When the HIGH POWER button is pressed the unit operates at maximum output for 30 minutes regardless of the d
47. marche arr t de fonctionnement ON OFF Ce bouton permet de mettre le climatiseur en marche et de l arr ter Bouton de temporisateur 1 heure 1 HR TIMER Qu il soit en service ou non quand ce bouton est actionn l appareil fonctionne pendant une heure puis il s arr te metteur Capteur Couvercle referm Afficheur S lecteur de vitesse du ventilateur FAN SPEED Bouton de volet FLAP Boutons de r glage de l heure de mise en marche ON TIME Bouton Pr c dent Bouton Suivant Bouton d annulation CANCEL Bouton de capteur de climatiseur SENSOR Bouton de l horloge CLOCK Bouton de r initialisation ACL Bouton de marche arr t de fonctionnement ON OFF Bouton de temporisateur 1 heure 1 HR TIMER Boutons de r glage de la temp rature TEMP S lecteur de mode MODE Bouton Suivant Bouton d conomie nocturne NIGHT SETBACK Bouton de haute puissance HIGH POWER Boutons de r glage de l heure d arr t OFF TIME Bouton Pr c dent Bouton d ionisation ION Commutateur d adresse ADDRESS Bouton de s lection de l affichage de la temp rature Bouton de s lection de l affichage de l heure Bouton de silencieux QUIET REMARQUE OI 803 8 F 02_KS0971_FR fm Page 32 Monday October 17 2005 7 46 PM 33 T l commande suite Boutons de r glage de la temp rature TEMP Appuyer sur le bouton pour augmenter la temp rature r gl
48. moves a flap up and down in the air outlet directing air in a sweeping motion around the room and providing comfort in every corner Auto Flap Control This automatically sets the flap to the optimum position during cooling and drying operation Automatic Restart Function for Power Failure Even when power failure occurs preset programmed operation can be reactivated once power resumes High Power Operation The unit operates at maximum output for 30 minutes regardless of the desired temperature The fan speed is 1 step above High Quiet Operation The fan rotates slower than the fan speed setting to provide a quieter operating sound ION Operation While it is operating the unit generates negative ions that freshen up the air in the room Anti Mold Filter This unit is equipped with an anti mold filter that inhibits the growth of mold and bacteria Air Clean Filter An air filter that eliminates unpleasant odors and cleans the air is available Purchase a replacement filter at your local dealer model STK FDXB OI 803 2 EG 01_KS0971_En fm Page 2 Monday October 17 2005 4 17 PM 3 Contents Page Features 2 Product Information 3 Alert Symbols
49. nt Mounting screws 5 32 x 5 8 4 x 16 mm included Rear side Hole To prevent loss of the remote control unit you can connect the remote control unit to the mount by passing a string through the remote control unit and attachment hole Press Set in place OI 803 11 EG 01_KS0971_En fm Page 11 Monday October 17 2005 4 17 PM 12 Operation with the Remote Control Unit 1 Operation Check that the circuit breaker on the power panel is turned on Press the setting buttons as described below and change the settings as desired STEP 1 Press the MODE selector button and select the desired mode For dehumidifying operation For cooling operation For fan only operation STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature Adjustable temperature range STEP 4 Set the FAN SPEED selector button to the setting you want STEP 5 Press the FLAP button and set the airflow direction as desired Refer to Adjusting the Airflow Direction on page 20 To stop the air conditioner press the ON OFF operation button again STEP 2 STEP 1 STEP 3 STEP 4 STEP 5 NOTE 30 C max 16 C min or 86 F max 60 F min OI 803 12 EG 01_KS0971_En fm Page 12 Monday October 17 2005 4 17 PM 13 Operation with the Remote Control Unit continued Choose
50. nts jouer avec le climatiseur Ne pas trop refroidir une pi ce o se trouvent des b b s ou des malades AVERTISSEMENT AVERTISSEMENT ATTENTION OI 803 4 F 02_KS0971_FR fm Page 28 Monday October 17 2005 7 46 PM 29 Nom des pi ces Le sch ma s appuie sur la vue externe du mod le standard En cons quence la forme risque de diff rer de celle du climatiseur sur lequel on a arr t son choix Le climatiseur se compose d un l ment int rieur et d un l ment ext rieur On pourra le piloter avec la t l commande Arriv e d air L air dans la pi ce entre dans cette section et il passe travers des filtres air qui liminent la poussi re Sortie d air L air climatis est souffl du climatiseur par la sortie d air T l commande La t l commande sans fil commande la mise sous hors tension ON OFF la s lection du mode de fonctionnement la temp rature la vitesse du ventilateur le r glage du temporisateur et le balayage d air Tuyaux de fluide frigorig ne Les l ments int rieur et ext rieur sont reli s par des tuyaux de cuivre par lesquels circule le fluide frigorig ne Tube de vidange L humidit de la pi ce se condense et est limin e par ce tube l ment ext rieur condensation L l ment ext rieur se compose d un compresseur d un moteur de ventilateur d une bobine d changeur de chaleur et d autres composants lectriques L MENT
51. on de r glage de l heure de mise en marche ON TIME L indicateur du temporisateur appara t et l heure de mise en marche ON actuelle est affich e 2 Appuyer sur les boutons Suivant et Pr c dent jusqu ce que AM 7 10 apparaisse L indicateur du temporisateur clignote L heure peut tre r gl e en incr ments de 10 minutes Si vous maintenez le bouton enfonc l heure change rapidement en incr ments de 10 minutes 3 Patienter quelques secondes pour que le r glage soit termin L indicateur du temporisateur cesse de clignoter et l heure actuelle s affiche 7 10 a m ON 11 00 a m OFF 10 30 p m L heure actuelle 1 Programmer les heures de marche et d arr t ON OFF comme indiqu sur 2 1 2 3 et 3 1 2 3 L heure actuelle 10 30 p m et sont affich s La programmation marche arr t combin e utilise l heure actuelle comme r f rence et elle est activ e l heure programm en premier Avec la programmation marche arr t combin e les r glages se r p tent quotidiennement Vous pouvez v rifier les heures de mise en marche et d arr t ON OFF du temporisateur une fois programm es en appuyant sur les boutons de r glage de l heure de mise en marche arr t REMARQUE REMARQUE OI 803 18 F 02_KS0971_FR fm Page 42 Monday October 17 2005 7 46 PM 43 Emploi du temporisateur 1 heure Conseils pour conomiser l nergie
52. oner will switch to the temperature sensor which is built into the indoor unit and control the room temperature In these cases the temperature around the remote control unit may differ from the temperature detected at the air conditioner s position How to Install Batteries The batteries last about six months depending on how much you use the remote control unit Replace the batteries when the remote control unit s display fails to light or when the remote control cannot be used to change the air conditioner s settings Use two fresh leak proof type AAA alkaline batteries In replacing batteries follow the instructions as mentioned in the sub section How to Install Batteries If you do not use the remote control unit more than 1 month take out the batteries NOTE NOTE 1 Slide the cover in the direction indicated by the arrow and remove it 2 Install two AAA alkaline batteries Make sure the batteries point in the direction marked in the battery compartment 3 Use a thin object such as the tip of a pen to press the ACL button ACL button NOTE OI 803 10 EG 01_KS0971_En fm Page 10 Monday October 17 2005 4 17 PM 11 Using the Remote Control Unit continued How to Use the Remote Control Unit When using the remote control unit always point the unit s transmitter head directly at the air conditioner s receiver Remote Control Unit Installation Position The remote control
53. procedure Press the ON OFF operation button to turn the unit off wait for the unit to stop operating and then press the ON OFF operation button again The 1 Hour Timer function is now cancelled and the unit operates normally If while the 1 Hour Timer function is operating the 1HR TIMER button is pressed once to cancel the function and then again the unit continues to operate for one hour from that point in time and then stops It is not possible to use the OFF Timer and 1 Hour OFF Timer together Whichever function is set last takes precedence If the 1 HR TIMER button is pressed while the TIMER OFF function operates the OFF Timer is cancelled and the unit will stop operating one hour later 2 Operation together with the DAILY ON OFF REPEAT Timer The 1 Hour OFF Timer setting is given priority over the DAILY ON OFF REPEAT setting Do not Block the air intake and outlet of the unit If they are obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and ceiling of the room are warmed by the sun it will take longer to cool the room Do Always try to keep the air filter clean Refer to Care and Cleaning A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed NOTE OI 803 19 EG 01_KS0971_En fm Page 19 Monday O
54. que le r glage soit termin L indicateur du temporisateur cesse de clignoter et l heure actuelle s affiche OI 803 17 F 02_KS0971_FR fm Page 41 Monday October 17 2005 7 46 PM 42 R glage du temporisateur suite 3 R glage du moment de mise en marche ON Exemple pour mettre le climatiseur en marche 7 10 a m 4 Comment programmer l heure de mise en marche arr t quotidienne DAILY ON OFF REPEAT Exemple pour mettre le climatiseur en marche 7 10 a m et l arr ter 11 00 a m Pour annuler une programmation Appuyez sur le bouton d annulation CANCEL Pour annuler une programmation quelconque mise en marche ou arr t appuyer sur le bouton correspondant au temporisateur dont le programme doit tre annul puis appuyez sur le bouton d annulation CANCEL Le r glage de la temp rature la direction du flux d air et la vitesse de ventilateur peuvent tre chang es apr s une programmation du temporisateur m me si le climatiseur est arr t M me lorsqu une op ration est interrompue durant une programmation de mise en marche ON le climatiseur d marre lorsque l heure programm e est atteinte dans la mesure o le programme n a pas t annul Lorsque la programmation ON Marche et la programmation OFF Arr t sont r gl es sur la m me heure la programmation fonctionne comme si elle tait arr t e D marche Affichage 1 Appuyer sur le bout
55. r 41 Emploi du temporisateur 1 heure 43 Conseils pour conomiser l nergie 43 R glage du flux d air 44 Fonctionnement sans t l commande 45 Entretien et nettoyage 45 Guide de d pannage 48 Plage de temp ratures de fonctionnement 48 Informations sur le produit Pour tout probl me ou toute question relatifs au climatiseur il faudra les informations ci dessous Les num ros de s rie et de mod le figurent sur la plaque signal tique plac e sur le fond du coffret No de mod le ___________________ No de s rie __________________ Date d achat____________________________________________________ Adresse du concessionnaire _______________________________________ Num ro de t l phone ___________ Symboles d avertissement Les symboles suivants utilis s dans ce manuel avertissent d un danger potentiel pour l utilisateur le personnel d entretien ou l
56. r indication is displayed and the present ON time is shown 2 Press the Advance Return button until AM 7 10 is displayed The timer indication blinks The time can be set in 10 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Wait a few seconds and then the setting is complete The timer indication stops blinking and the present time is displayed 7 10 am ON 11 00 am OFF 10 30 pm Present time 1 Set the timer ON OFF times as shown in 2 1 2 3 and 3 1 2 3 The present time 10 30 pm and are displayed The ON OFF combination timer uses the current time as the reference and it is activated starting from whichever set time comes first With the ON OFF combination timer the settings are repeated every day You can check the timer ON OFF times after you have set them by pressing the ON TIME and OFF TIME setting buttons NOTE NOTE OI 803 18 EG 01_KS0971_En fm Page 18 Monday October 17 2005 4 17 PM 19 Using the 1 Hour OFF Timer Tips for Energy Saving 1 1 Hour OFF Timer This function causes the unit to operate for one hour and then stop regardless of whether the unit is on or off when this button is pressed The indicator in the display indicates that this function is operating Setting procedure Regardless of whether the unit is operating or stopped press the 1 HR TIMER button appears in the display Cancellation
57. re 2 Laisser le bord de la grille d arriv e d air glisser dans la partie sup rieure de l appareil puis ins rer la fond l int rieur 3 Appuyer sur les coins inf rieurs droit et gauche de la grille d arriv e d air pour l attacher l appareil Attacher de sorte que les goupilles rondes des coins sup rieurs droit et gauche de la grille d arriv e d air soient ins r es dans les rainures sur la partie sup rieure droite et gauche de l appareil Grille d arriv e d air Filtre anti moisissure Filtre anti moisissure Marque FRONT Crochet Grille d arriv e d air Rainure Goupille Grille d arriv e d air REMARQUE OI 803 22 F 02_KS0971_FR fm Page 46 Monday October 17 2005 7 46 PM 47 Entretien et nettoyage suite Filtre de nettoyage d air Le filtre de nettoyage d air limine les poussi res et salet s contenues dans l air et il r duit les odeurs et la fum e de tabac Ce filtre de nettoyage d air ne permet ni d liminer les vapeurs et les gaz nocifs ni de ventiler l air de la salle Il faut donc ouvrir fr quemment les portes ou les fen tres si l on utilise des appareils de chauffage au gaz ou au p trole Faute de quoi on s exposerait dans les cas extr mes un risque d asphyxie Installation du filtre de nettoyage d air Le filtre d air doit tre install derri re la grille d arriv e d air 1 Retirer la grille d arriv
58. re inserted into the grooves at the top right and left of the indoor unit Air intake grille Anti mold filter Anti mold filter FRONT mark Hook Air intake grille Groove Pin Air intake grille NOTE OI 803 22 EG 01_KS0971_En fm Page 22 Monday October 17 2005 4 17 PM 23 Care and Cleaning continued Air Clean Filter The air clean filter removes dust and dirt from the air and reduces odors and smoke from tobacco This air clean filter cannot remove harmful gases or vapors nor ventilate air in the room You must open doors or windows frequently when you use gas or oil heating appliances Otherwise there is a risk of suffocation in extreme cases How to install the air clean filter The air clean filter needs to be installed behind the air intake grille 1 Remove the air intake grille 2 Install the air clean filter in the position shown in the figure 3 Remount the air intake grille How to clean the air clean filter In general the filter should be sucked to remove dust in low fan speed of a vacuum cleaner once every three months If there is heavily grime on the filter soak the filter in lukewarm water with neutral detergent diluted 1 500 for 1 to 2 minutes then wash it Rinse the filter in clean water then let it dry on the towel in room temperature Do not bend nor give excessive force onto the air clean filter If the filter surface is heavily blocked with dirt or damaged r
59. s m talliques l int rieur du bo tier en plastique AVERTISSEMENT REMARQUE OI 803 23 F 02_KS0971_FR fm Page 47 Monday October 17 2005 7 46 PM 48 Guide de d pannage Si le climatiseur ne fonctionne pas correctement effectuer les v rifications suivantes avant de faire appel un r parateur Si le probl me persiste prendre contact avec son concessionnaire ou avec un service apr s vente Plage de temp ratures de fonctionnement Le climatiseur peut fonctionner dans la plage de temp ratures indiqu e ci dessous Mod les refroidissement uniquement C0971 C1271 Mod les refroidissement basse temp rature ambiante CL0971 CL1271 Panne Cause possible Rem de Le climatiseur ne fonctionne pas du tout 1 Coupure de courant 1 R tablir l alimentation 2 Le disjoncteur a fonctionn 2 Prendre contact avec un service apr s vente 3 Tension de ligne trop basse 3 Consulter un lectricien ou le concessionnaire 4 Les piles de la t l commande sont us es 4 Remplacer les piles Le voyant de fonctionnement OPERATION clignote et le climatiseur ne fonctionne pas Probl me dans l appareil Prendre contact avec un service apr s vente Le compresseur se met en marche mais il s arr te aussit t Il y a un obstacle devant la bobine du condensateur Retirer ce qui fait obstruction Refroidissement insuffisant 1 Filtre air sale ou obstru 1 Nettoyer le filtre
60. sur la vitesse faible afin de fournir une brise confortable Un fonctionnement du s chage DRY n est pas possible si la temp rature int rieure est de 59 F ou moins Il se peut que parfois l l ment int rieur n atteigne pas la vitesse de ventilateur sp cifi e comme par exemple en mode LOW et QUIET lorsqu il fonctionne froid temp rature ext rieure tr s basse car l l ment int rieur est prot g contre la glace et le gel lorsqu il est combin un mod le d l ment ext rieur con u pour fonctionner temp rature ambiante basse En cas d une panne de courant l appareil s arr te Lorsque le courant est r tabli l appareil se remet en marche automatiquement en moins de cinq minutes par la t l commande Le climatiseur produit un cliquetis A la suite d un changement de temp rature provoqu par refroidissement les pi ces en plastique de l appareil se r tr cissent ce qui provoque un l ger cliquetis C est normal et le son dispara tra apr s quelques instants La t l commande transmet r guli rement l tat du r glage au climatiseur intervalles de cinq minutes Fonctionnement s chage Refroidissement Panne de courant pendant le fonctionnement Cliquetis T l commande OI 803 16 F 02_KS0971_FR fm Page 40 Monday October 17 2005 7 46 PM 41 R glage du temporisateur Dans les descriptions ci dessous les r glages
61. t rieure quand le mode d conomie nocturne a t s lectionn Ceci permet d conomiser l nergie sans sacrifier le confort Cette fonction est pratique lorsqu on d sire un refroidissement mod r Temp rature r gl e Appuyez sur le bouton d conomie nocturne NIGHT SETBACK 30 minutes 30 minutes Temps 2 F 2 F OI 803 14 F 02_KS0971_FR fm Page 38 Monday October 17 2005 7 46 PM 39 Fonctionnement avec t l commande suite 5 Mode de silencieux QUIET Le mode de silencieux QUIET est utilis pour r duire le son du ventilateur de l appareil Appuyez sur le bouton de silencieux QUIET appara t sur l afficheur Pour annuler appuyez de nouveau sur le bouton de silencieux QUIET En mode de silencieux le ventilateur tourne une vitesse plus faible que celle sur laquelle est r gl le ventilateur Si l appareil fonctionne d j avec un flux d air tr s faible le bruit du ventilateur peut ne pas changer m me si le bouton de silencieux QUIET est enfonc 6 Mode de fonctionnement haute puissance HIGH POWER Le mode de fonctionnement haute puissance HIGH POWER peut tre utilis pour augmenter la sortie de l l ment int rieur pour tous les modes de fonctionnement Appuyez sur le bouton de haute puissance HIGH POWER appara t sur l afficheur Pour annuler appuyez de nouveau sur le bouton de haute puissance HIGH POWER Lorsqu
62. the best position in the room for the remote control unit which also acts as the sensor for room comfort and transmits the operating instructions Once you ve found this best position always keep the remote control unit there This appliance has a built in 5 minute time delay circuit to ensure reliable operation When the operation button is pressed the compressor will start running within three minutes In the event of power failure the unit will stop 2 Adjusting the Fan Speed A Automatic fan speed Simply set the FAN SPEED selector button to the position This automatically sets the best fan speed for the room temperature B Manual fan speed If you want to adjust fan speed manually during operation just set the FAN SPEED selector button as desired or 3 Fan Only If you want to circulate air without any temperature control follow these steps STEP 1 Press the MODE selector button to switch to the fan mode STEP 2 Press the ON OFF operation button STEP 3 Press the FAN SPEED selector button to select the fan speed of your choice or NOTE STEP 2 STEP 1 STEP 3 OI 803 13 EG 01_KS0971_En fm Page 13 Monday October 17 2005 4 17 PM 14 Operation with the Remote Control Unit continued 4 Night Setback Mode Night Setback Mode is used for saving energy Press the NIGHT SETBACK button while operation The mark appears in the display To release the night setback funct
63. tion of transmission 7 Auto fla dication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation 10 ION operation Displayed when setting timer Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when the time display is set to 12 hour time Symbols OI 803 7 EG 01_KS0971_En fm Page 7 Monday October 17 2005 4 17 PM 8 Remote Control Unit The illustration above pictures the remote control unit after the cover has been opened Transmitter When you press the buttons on the remote control unit the mark appears in the display to transmit the setting changes to the receiver in the air conditioner Sensor A temperature sensor inside the remote control unit senses the room temperature Display Information on the operating conditions is displayed while the remote control unit is switched on If the unit is turned off FLAP setting and FAN SPEED setting are not displayed ION button This button is for turning the negative ions generated during operation on and off ON OFF operation button This button is for turning the air conditioner on and off 1 HR TIMER button 1 HOUR OFF TIMER When you press this button regar
64. ue apr s une panne de courant M me apr s une panne de courant les programmations sont remises en service lorsque le courant est r tabli Fonctionnement haute puissance L unit op re sortie maximale pendant 30 minutes ind pendamment de la temp rature d sir e La vitesse du ventilateur est un palier sup rieur lev e Fonctionnement silencieux Le ventilateur tourne plus lentement que la vitesse sur laquelle est r gl le ventilateur pour fournir un son de fonctionnement plus doux Fonctionnement d ionisation Lorsqu il est activ l appareil g n re des ions n gatifs qui rafra chissent l air dans la pi ce Filtre anti moisissure Cet appareil est muni d un filtre anti moisissure qui retarde la croissance de toute moisissure ou bact rie Filtre de nettoyage d air Un filtre air qui limine les odeurs d sagr ables et purifie l air est disponible Acheter un filtre de remplacement aupr s du d positaire local mod le STK FDXB OI 803 2 F 02_KS0971_FR fm Page 26 Monday October 17 2005 7 46 PM 27 Table des mati res Page Caract ristiques 26 Informations sur le produit 27 Symboles d avertissement
65. ury if handled improperly be especially careful when you clean these parts 3 The internal coil and other components of the outdoor unit must be cleaned every year Consult your dealer or service center OPERATION button Cooling operation Stop NOTE CAUTION OI 803 21 EG 01_KS0971_En fm Page 21 Monday October 17 2005 4 17 PM 22 Care and Cleaning continued Anti Mold Filter The anti mold filter behind the air intake grille should be checked and cleaned at least once every two weeks How to remove the anti mold filter 1 Grasp both ends of the air intake grille and remove it by opening towards the front and pulling towards you 2 Remove the anti mold filter attached to the rear of the air intake grille Cleaning Use a vacuum cleaner to remove light dust If there is sticky dust on the filter wash the filter in lukewarm soapy water rinse it in clean water and dry it How to replace the anti mold filter 1 With the FRONT mark of the anti mold filter at the front align the two indentions near the mark with the hooks at the rear of the air intake grille and then mount the anti mold filter 2 Allow the edge of the air intake grille to slide into the top of the indoor unit and then insert it all the way inside 3 Press in the bottom right and left corners of the air intake grille to attach the indoor unit Attach so that the round pins at the top right and left corners of the air intake grille a
Download Pdf Manuals
Related Search
Related Contents
Lumiscope 1145 User's Manual ミロ / ミロ プラス 取扱説明書(耳あな型) RegistRate on line il vostRo pRodotto vateRRa significato dei WHITE LIGHTNINGTM WHITE LIGHTNINGTM CURTIS – TOLEDO - Air Compressors Direct Copyright © All rights reserved.
Failed to retrieve file