Sanyo KS0951 User's Manual

image

Contents

1. Clean the casing and grille of the indoor unit with a vacuum cleaner brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with a mild liquid detergent When cleaning the grille be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe the plastic casing using very hot water 2 Some metal edges and the fins are sharp and may cause injury if handled improperly be especially careful when you clean these parts 3 The internal coil and other components of the outdoor unit must be cleaned every year Consult your dealer or service center 19 Care and Cleaning continued Anti mold filter The anti mold filter behind the air intake grille should be checked and cleaned at least once every two weeks Air intake grille How to remove the 1 Grasp both ends of the anti mold filter air intake grille and pull it out and up 2 Push the anti mold filter up slightly and then pull it down CEL D Anti mold filter Cleaning Use a vacuum cleaner to remove light dust If there is sticky dust on the filter wash the filter in lukewarm soapy water rinse it in clean water and dry it How to replace the 1 With the FRONT mark facing anti mold filter you slide the anti mold filter Air intake grille up into the unit and then lower the handle into the groove on the unit 2 After installin
2. Symbols 4 Timer Oo 12 hour ON Timer ONG 12 hour OFF Timer 1 hour OFF Timer 1HRE 5 NIGHT SETBACK as 6 Confirmation of transmission CA 333 a Angle indication Sweep indication M 7 Remote Control Unit Transmitter SET TEMP A Display SILI de xd Zn DW C l d ON OFF operation button Cover closed 1 HR TIMER button Temperature setting buttons TEMP FAN SPEED selector button FLAP button TIMER ON button TIMER OFF button MODE selector button NIGHT SET CANCEL SETBACK NIGHT SETBACK button SET button E ou CANCEL button U same que ADDRESS switch m a ACL button AB O mn np Pull off the cover to expose the Ri NOTE The illustration above pictures the remote control unit after the cover has been lowered and removed Transmitter When you press the buttons on the remote control unit the mark appears in the display and the setting changes are transmitted to the receiver in the air conditioner Display Information on the operating status is displayed while the remote control unit is switched on If the unit is turned off only the mode that was set previously ts still displayed NIGHT SETBACK button For details see Night Setback Mode When you press this button in the DRY or COOL mode the mark appears in the display and the remote control unit automatically adjust
3. NOTE Set the 1 Hour OFF Timer and the 12 Hour ON Timer simultaneously Unless you set the 1 Hour OFF Timer and the 12 Hour ON Timer at the same time the 1 Hour OFF Timer may operate for one hour or more O1 330 17EG 17 Adjusting the Airflow Direction 1 Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right position during the cooling or drying operation If the vertical vanes are positioned all of the way to the right or left condensation may begin to form around the air vent and drip down CAUTION When the humidity is high the vertical vanes should be in the front 2 Vertical The vertical airflow can be adjusted by moving the flap with the remote control unit Do not move the flap with your hands Confirm that the remote control unit has been turned on Use the FLAP button to set either the sweep function or one of the six airflow direction settings The maximum capacity is obtained at the position at and A SWEEP D _ DRY ER Recommended D D gt Operating y aZ range a CY A Sweep function B Setting the airflow manually M The flap starts moving up and down to a Referring to the above illustration use 71 deliver air over the sweep range the FLAP button to set the airflow direction within the range used during the cooling or drying operation NOTE The flap automatically closes when the unit is off CA
4. operation button STEP 3 Press the temperature setting buttons to change the temperature setting to the desired temperature Adjustable temperature range 88 F max 60 F min NOTE The temperature setting changes by one degree each time the button is pressed The air conditioner remembers the new temperature setting even when it is turned off STEP 4 Press the FLAP button and set the airflow direction as desired Refer to Adjusting the Airflow Direction on page 18 To stop the air conditioner press the ON OFF operation button again Ol 330 12EG 2 Adjusting the Fan Speed A Automatic Cooling and DRY mode OI 330 13EG B Manual Operation with the Remote Control Unit continuedl e This appliance has a built in three minutes time delay circuit to ensure reliable operation When the operation button is pressed the compressor will start running within three minutes In the event of power failure the unit will stop When the power is restored the unit will restart automatically after five minutes Simply set the FAN SPEED selector button to the position A microcomputer in the air conditioner automatically controls the fan speed when the mode is selected When the air conditioner starts operating the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level When difference be
5. batteries follow the instructions as mentioned in the sub section How to Install Batteries If you do not use the remote control unit more than 1 month take out the batteries When using the remote control unit always point the unit s transmitter head directly at the air conditioner s receiver Air conditioner Indoor unit Remote control ae unit Vor The remote control unit may be operated either from a non fixed position or from a wall mounted position To ensure that the air conditioner operates correctly DO NOT install the remote control unit in the following places In direct sunlight Behind a curtain or other places where it is covered More than 26 feet 8 m away from the air conditioner In the path of the air conditioner s airstream Where it may become extremely hot or cold e Where it may be subject to electrical or magnetic noise e Where there is an obstacle between the remote control unit and air conditioner since a check signal is sent from the remote control unit every 5 minutes OI 330 10EG Using the Remote Control Unit continued Mounting the Remote Control Unit Removable mounting Non removable mounting te Packed with the indoor unit Wall Packed with the indoor unit Mounting on a wall A Removable mounting 1 Momentarily hold the remote control unit at the desired mounting position 2 Confirm that the air conditioner responds correctly when you pr
6. outlet NOTE This illustration is based on the external appearance of a standard model Consequently the shape may differ from that of the air conditioner which you have selected This air conditioner consists of an indoor unit and an outdoor unit You can control the air conditioner with the remote control unit Air from the room is drawn into these sections and passes through air filters which remove dust Air is blown out of the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power on off operation mode selection temperature fan speed timer setting night setback and air sweeping Refrigerant Tubes The indoor and outdoor units are connected by copper tubes through which refrigerant gas flows Moisture in the room condenses and drains off through this hose Outdoor Condensing Unit The outdoor unit contains the compressor fan motor heat exchanger coil and other electrical components O1 330 05EG 5 Unit Display and Operation Selector INDOOR UNIT KS1852 INDOOR UNIT Operation selector KS0951 KS1251 Remote control receiver OPERATION TIMER A IMPORTANT Avoid using radio equipment such as mobile phones near within 1 m of the indoor unit Some radio equipme
7. port Thermostat is set too high for cooling In cooling and drying operation any plastic parts may expand or shrink due to a sudden temperature change In this event a clicking sound may occur Clicking sound is heard from the air conditioner OPERATION lamp lights but outdoor unit will not run 1 The use of portable telephones near the air conditioner may cause disturbance to its normal operation Operating Range 1 Restore power 2 Contact service center 3 Consult your electrician or dealer 4 Press the button again 5 Replace batteries Contact service center 1 Clean air filter to improve airflow 2 Eliminate heat source if possible 3 Shut them to keep the heat out 4 Remove it to ensure good airflow 5 Set the temperature lower This is normal and the sound will soon disappear 1 Turn off the power then restart the air conditioner after 1 minute 2 Consult your dealer The air conditioner is operable within the temperature ranges as listed below Temperature Indoor Air Intake Temperature Outdoor Air Intake Temperature 95 F DB 71 F WB 67 F DB 57 F WB 95 F DB 71 F WB 67 F DB 57 F WB Maximum ne Maximum Minimum Low Ambient Temperature Model OI 330 23EG 115 F DB 67 F DB 115 F DB 0 F DB 23 SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 Plummer Street Chatsworth CA 91311 U S A In Cana
8. SANYO INSTRUCTION MANUAL Split System Air Conditioner KS0951 KS1251 KS1852 Save These Instructions VERIFIED Energy Se Performace PLANS Rendement TTY AN Energ tique V RIFI Pub Ol 85264180330002 SANYO 2000 Printed on Recycled Paper Features This air conditioner is equipped with cooling and drying functions Details on these functions are provided below refer to these descriptions when using the air conditioner Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation each logically displayed for easy use Simple One touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation 12 Hour ON or OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 12 hour period 1 Hour OFF Timer This timer can be set to automatically turn off the unit at any time after one hour Night Setback Pressing this button changes the setting of the room temperature thermostat allowing you to set the temperature at whatever level that you find comfortable Automatic and 3 step Fan Speed Auto High Medium Low Air Sweep Control This function moves a flap up and down in the air outlet directing air in a sweeping motion around the room and providing comfort in every corner Automatic Restart Function for Power Failure Even when power failur
9. UTION e Use the FLAP button on the remote control to adjust the position of the flap If you move the flap by hand the flap position according to the A remote control and the actual flap position may no longer match If this should happen shut off the unit wait for the flap to close and then turn on the unit again the flap position will now be normal again Do not have the flap pointed down during cooling operation Condensation may begin to form around the air vent and drip down 18 O1 330 18EG INDOOR UNIT KS0951 KS1251 Operation KS1852 selector Operation selector Casing and Grille Indoor Unit NES OI 330 19EG Operation without the Remote Control Unit If you have lost the remote control unit or it has trouble follow the steps below 1 When the air conditioner is not running If you want to turn on the air conditioner switch the operation selector to the OFF position and then to the ON position NOTE The set temperature and fan speed are automatically set at the last selection before stopping 2 When the air conditioner is running If you want to turn off the air conditioner switch the operation selector to the OFF position Care and Cleaning 1 For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning 2 Do not pour water on the indoor unit to clean it This will damage the internal components and cause an electric shock hazard
10. da SANYO Canada Inc 50 Beth Nealson Drive Toronto Ontario M4H 1M6 Canada
11. e occurs preset pro grammed operation can be reactivated once power resumes Anti Mold Filter This unit is equipped with an anti mold filter that inhibits the growth of mold and bacteria Optional Air Clean Filter An air filter that uses activated charcoal to eliminate unpleasant odors and clean the air is available sold separately OI 330 02EG OI 330 03EG Contents Page OS ee 2 Product Informatio M ed ari 3 ALT RD OS E N ee ee ee ee 3 Installation Location RE 4 Electrical Requirements a a a nn 4 Se OS COS a a tie 4 Names OS 0 5 Using the Remote Control Unit 10 Operation with the Remote Control Unit ss 12 1 Manu al OperatiOM ae etes ein a 12 2 Adjusting the Fan Speed ss 13 2 Night Setback Mode es onee duree ted net 14 ne 81518 RSS ee 15 Using the 12 Hour ON and OFF Timer 16 Using the 1 Hour OFF TIME nr suce cene d esno tes semuebe ttes descuun 17 Adjusting the Airflow Direction LL 18 Operation without the Remote Control Unit 19 Care and Cleaning irens aaa i a ENTENEN 19 Tips for Energy Saving sssesimeerreerssdror ini nher arn a est Ee a ERr per ai 22 Troubleshooting 23 SOF GUI GE IG 6 a R R A ERA 23 Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No Serial No Date of purchase Dealer s address Phone number A
12. ent may be used to remove stubborn dirt Then rinse thoroughly with water and wipe away any remaining moisture Tips for Energy Saving Block the air intake and outlet of the unit If they are obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and ceiling of the room are warmed by the sun it will take longer to cool the room Always try to keep the air filter clean Refer to Care and Cleaning A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed OI 330 22EG Troubleshooting If your air conditioner does not work properly first check the following points before requesting service If it still does not work properly contact your dealer or service center Possible Cause 1 Power failure 2 Leakage circuit breaker tripped 3 Line voltage is too low 4 Operation button is OFF 5 Batteries in remote control unit have run down Air conditioner does not run at all OPERATION lamp flashes and air conditioner does not operate Compressor runs but Obstruction in front of condenser coil Remove obstruction soon stops Poor cooling performance Trouble in wiring system Dirty or clogged air filter Heat source or many people in room Doors and or windows are open Obstacle near air intake or air discharge
13. ess keys on the remote control from that position 3 After confirming correct operation use a screwdriver to screw the mounting screw into the wall 4 Hang the remote control unit from the mounting screw B Non removable mounting 1 Momentarily hold the remote control unit at the desired mounting position 2 Confirm that the air conditioner responds correctly when you press keys on the remote control from that position 3 After confirming correct operation use a screwdriver to screw the mounting screw into the wall 4 Remove the batteries of the remote control unit 5 Use a screwdriver to screw the remote control unit securing screw into the wall through the hole in the battery compartment 6 Replace the batteries 7 Again confirm that the remote control unit operates correctly O1 330 11EG 11 1 Manual Operation Operation with the Remote Control Unit SET TEMP He STEP 3 STEP 1 ONo OFFO C C SET CANCEL SETBACK C CJC Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position If the automatic operation settings of the unit do not meet your needs press the setting buttons as described below and change the settings as desired Press the MODE selector button and select the desired mode For drying operation gt For cooling operation gt H STEP 2 To start the air conditioner press the ON OFF
14. ety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual the air conditioner it is very dangerous This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or oil heating appliances in the same room which consume a lot of oxygen from the air Otherwise there is a risk of suffocation in an extreme case ES Never use or store gasoline or other flammable vapor or liquid near CAUTION Do not turn the air conditioner on and off from the power mains switch Use the ON OFF operation button Do not stick anything into the air outlet of the outdoor unit This is dangerous because the fan is rotating at high speed Do not let children play with the air conditioner Do not cool the room too much if babies or invalids are present OI 330 04EG Names of Parts INDOOR UNIT Air intakes ON 7 Air outlet aS gt Remote control unit Drain hose C gt ce Cd Refrigerant tubes OUTDOOR UNIT Air
15. g the anti mold filter press the locations marked by the arrows J and close the air intake grille Anti mold filter Insert into the groove on the unit 20 O1 330 20EG Air cleaning filter not provided ANET How to install the air cleaning filter Cleaning the main unit and remote control unit Care and Cleaning continued The air cleaning filter removes dust and dirt from the air and reduces odors and smoke from tobacco KS0951 KS1251 The air cleaning filter is not provided with the air conditioner and must be purchased separately The first time that you buy the air clean filter it is necessary to get the STK ARF4B model with frame When changing the filter subsequently it is only necessary to replace the filter itself model STK F4B Do not throw away the filter frame KS1852 The air clean filter is not provided with the air conditioner and must be purchased separately Ask for the STK F4B model when purchasing The air cleaning filter cannot remove harmful gases or vapors nor ventilate air in the room You must open doors or windows frequently when you use gas or oil heating appliances Otherwise there is a risk of suffocation in extreme cases Air clean filter The air cleaning filter needs to be STK F4B installed behind the anti mold filter 1 Remove the anti mold filter A SSS 2 To mount the STK F4B set the A SG air clean filter sold separately at the mounting posi
16. lert Symbols The following symbols used in this manual alert you to potentially dangerous conditions to users service personnel or the appliance WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death f CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage Installation Location We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit e Before installation check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate ANETO Do not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generating objects are placed Avoid To protect the air conditioner from heavy corrosion avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa Electrical Requirements 1 All wiring must conform to the local electrical codes Consult your dealer or a qualified electrician for details 2 Each unit must be properly grounded with a ground or earth wire or through the supply wiring 3 Wiring must be done by a qualified electrician Saf
17. ng procedure Regardless of whether the unit is operating or stopped press the 1 HR TIMER button appears in the display Cancellation procedure Press the ON OFF operation button to turn the unit off wait for the unit to stop operating and then press the ON OFF operation button again The 1 Hour Timer function is now cancelled and the unit operates normally FLAP FAN SPEED MODE Cu CD CD ONQ OFFO C_D CD NIGHT SET CANCEL SETBACK min 7 ___ f while the 1 Hour Timer function is operating the 1 HR TIMER button is pressed once to cancel the function and then again the unit continues to operate for one hour from that point in time and then stops e f the 1 HR TIMER button is pressed while the TIMER OFF function is operating the OFF Timer is cancelled and the unit stops operating one hour later 2 Combining the 1 Hour By combining the 1 Hour OFF Timer and 12 Hour ON Timer it is possible to OFF Timer and 12 Hour have the unit operate for just one hour from the present time and then have it switch on again later at a time specified by you ON Timer Example Having the unit operate for just one hour from the present time and then switch on again three hours from the present time Timer setting Operate Operate 2 hours 3 hours Setting procedure STEP 1 Press the 1 HR TIMER button STEP 2 Press the TIMER ON button and use the SET button to set the unit to turn on three hours later
18. nt may cause the unit to malfunction TIMER lamp If the trouble occurs disconnect power and restart the OPERATION lamp air conditioner after a few minutes Remote control receiver This section picks up infrared signals from the remote control unit transmitter Operation selector ON position This position is for operating the air conditioner with the wireless remote control unit Set the selector normally in this position OFF position Switch the selector to the OFF position if you are not going to use the air conditioner for a few days or longer WARNING The OFF position does not disconnect the power Use the main power switch to turn off power completely TEST position This position is used only when servicing the air conditioner CAUTION Do not set at the TEST position for normal operation OPERATION lamp This lamp lights when the system is in the continuous DRY and COOL mode TIMER lamp This lamp lights when the system is being controlled by the timer _ lamp This lamp lights when the system is being controlled by the timer _ when the system is being controlled by the timer 6 O1 330 06EG 1 Operation MILD DRY 2 n gt U O O O an 3 60 88 F Remote Control Unit Display mode Temperature setting When set to 82 F temperature indication OI 330 07EG Displayed when setting temperature Displayed when transmitting data Displayed when setting timer
19. s the set temperature to save energy Temperature setting Press the button to increase the temperature setting buttons TEMP Press the button to reduce the temperature setting ON OFF operation This button is for turning the air conditioner on and off button TIMER ON button The air conditioner starts at the set time TIMER OFF button OFFS The air conditioner stops at the set time 8 O1 330 08EG Remote Control Unit continued MODE selector button Use this button to select the DRY or COOL mode DRY The air conditioner reduces the humidity in the room COOL ge The air conditioner makes the room cooler FLAP button Press this button either to select to set the airflow direction to one of the six possible positions manually or to select the sweep function which moves the flap up and down automatically N The airflow direction can be set manually six positions zN The flap moves up and down automatically NOTE To switch to the sweep function 2 when in the manual 4 mode hold down the FLAP button Refer to Adjusting the Air Flow Direction on page 18 FAN SPEED selector The air conditioner automatically decides the fan speed button High fan speed Medium fan speed Low fan speed 1 HR TIMER button When you press this button regardless of whether the unit is 1 hour off timer operating or stopped the unit operates for one hour and then shuts down ACL button All clear Puts
20. te Control Unit page 12 Press the TIMER ON button which advances the time delayed To set the time at which you want operation to begin The time can be set to from one to twelve hours in one hour steps _STEP3 Press the SET button The display changes immediately to its status previous to timer setting but the indication remains To check the status of the timer while it is counting down press the SET button Cancellation procedure Press the CANCEL button After the length of time set for TIMER OFF elapses the unit stops operating The display depicted at left indicates that the air conditioner will stop operating in five hours Setting procedure Press the TIMER OFF button during operation which advances the time displayed To set the time at which you want operation to stop The time can be set to from one to twelve hours in one hour steps STEP2 Press the SET button The display changes immediately to its status previous to timer setting but the OFFS indication remains To check the status of the timer while it is counting down press the SET button Cancellation procedure Press the CANCEL button OI 330 16EG Using the 1 Hour OFF Timer 1 1 Hour OFF Timer This function causes the unit to operate for one hour and then stop regardless of whether the unit is on or off when the button is pressed The indicator in the display indicates that this function is operating Setti
21. the remote control unit into pre operation status Always press this button after replacing the batteries SET button After using the TIMER ON button or TIMER OFF button to set the timer press this button to activate the new setting CANCEL button Press this button to cancel the current timer ON and OFF setting ADDRESS switch The address switch changes to prevent mixing of signals from remote control units when two Sanyo air conditioners are installed next to each other Normally the address switch is set to A When switching the address the remote control unit must be changed to B For more information please contact the dealer where you made the purchase O1 330 09EG 9 How to Install Batteries How to Use the Remote 10 Control Unit Remote Control Unit Installation Position DO NOT Using the Remote Control Unit 1 Slide the cover in the direction indicated by the arrow and remove it 2 Install two AAA alkaline batteries Make sure ACL button the batteries point in the direction marked in the battery compartment 3 Use a thin object such as the tip of a pen to press the ACL button The batteries last about six months depending on how much you use the remote control unit Replace the batteries when the remote control unit s display fails to light or when the remote control cannot be used to change the air conditioner s settings Use two fresh leak proof type AAA alkaline batteries In replacing
22. tion with the black side facing the rear To mount the STK ARF4B mount the air clean filter in the position shown in the diagram with the STK F4B FRONT marking facing the front 3 Reinstall the anti mold filter and close the suction grill KS1852 Air clean filter In general the filter should be DIR ARTAB Z lt replaced once every three gt N I months gt RR e Dirty air clean filters cannot be washed and reused Purchase a replacement filter at your local dealer KS0951 KS1251 Wipe clean using a soft dry cloth To remove stubborn dirt moisten a cloth in warm water no hotter than 104 F wring thoroughly and then wipe The air intake grille can be removed in order to wash it with water 21 Removing and remounting 22 the air intake grille NES Washing the grille with water Do not Do Care and Cleaning continued With the air intake grille open Air intake grille all the way grip both arms with your hands and pull toward you to remove To remount hold the air intake grille roughly horizontal and push it in until the arm shafts fit into the indentations tn the main unit then fit the grille into place DE When using a footstool or the like be careful not to let it tip over Clean the grille gently using a soft sponge or the like Then wipe away any remaining moisture Neutral deterg
23. tween room temperature and set temperature is If you want to adjust fan speed manually during operation just set the FAN SPEED selector button as desired 83 8 or 13 Operation with the Remote Control Unit continued 3 Night Setback Mode SET TEMP Y BATTERIES O ACL The Night Setback Mode is used for saving energy Press the NIGHT SETBACK button while the air conditioner is operating The mark appears in the display To cancel the night setback function press the NIGHT SETBACK button again In Cooling and DRY Mode When the night setback mode is selected the air conditioner and automatically raises the temperature setting 2 F when 30 minutes have passed after the selection was made and then another 2 F after another 30 minutes have passed regardless of the indoor temperature when night setback was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle cooling is needed Setting temperature Es Press the 30 min NIGHT SETBACK button 14 O1 330 14EG DRY 9 Operation How it works Power failure during operation Clicking Sound Clicking sound is heard from the air conditioner Remote Control Unit A IMPORTANT KS1852 and CL1852 OI 330 15EG Combination Special Remarks Once the room temperature reaches the level that was set the unit repeats the cycle of turning on and off a
24. utomatically During DRY operation the fan speed is automatically set to LOW or VERY LOW the fan speed then switches back and forth between LOW for 20 seconds and VERY LOW for 10 seconds DRY operation is not possible if the indoor temperature is 59 F or less In the event of power failure the unit will stop When the power is turned on again the unit restarts within five minutes In cooling and drying operation any plastic parts may expand or shrink due to a sudden temperature change In this event a clicking sound may occur This is normal and the sound will soon disappear The remote control unit sends the setting condition to the air conditioner regularly at five minute intervals When this unit is combined with the CL1852 outdoor unit set the indoor airflow to medium or high when the outdoor temperature drops below 32 F to prevent condensation from forming at the indoor unit 15 1 TIMER ON mode Example 2 TIMER OFF mode 16 Example D afl H OFO FLAP FAN SPEED MODE as 2 eae ONO OFFO SS NIGHT Ill SET CANCEL SETBACK CD OACL Using the 12 Hour ON and OFF Timer After the length of time set for TIMER ON elapses the unit begins operating The display depicted at left indicates that the air conditioner will begin operating in three hours Setting procedure Press the MODE selector button and select the desired Operation mode See Operation with the Remo

Download Pdf Manuals

image

Related Search

Related Contents

Internal Catering Booking with FoodHertfordshire User Guide www  Cisco Systems OL-4580-01 User's Manual  Composteur rotatif  取扱説明書  S4M Guida per l`utente    Conceptronic Bluetooth 2.0 USB Adapter, 200m  Benutzerhandbuch HAS IV - Akademie der Wissenschaften und der  f50000 Acidrina  1 USER GUIDE LFS TWO-QUARTER AND FIVE  