1. a 14 PROGRAMMING YOUR AIR CONDITIONER m Switching the Unit On and Off Automatically On Off Timer 15 m Setting the Sleep Timer u 16 m Setting the Quick Timer nennen 16 m Cancelling the On Off Timer u 17 m Cancelling the Sleep Timer u 17 m Cancelling the Quick Timer enn 17 RECOMMENDATIONS FOR USE m Operating Recommendation nennen 18 m Temperature and Humidity Ranges see 18 m Cleaning Your Air Conditioner a 19 m Solving Common Problems sse 20 m Operating Your Air Conditioner Without the Remote Control 21 m Installing a Filter Option 22 TECHNICAL SPECIFICATIONS cc cccccescesccescesccessesecenscseceescsecsescaesseseseeuseausesecsusesneeneeas 22 E 3 ENGLISH View of the Indoor Unit ON OFF switch operation without remote control Air flow blades outlet Air Filter A under the grille Remote control sensor Air Inlet OPERATION TIMER FAN TURBO lt lt mm m ps OPERATION indicator e TURBO indicator GREEN RED TIMER indicator FAN indicator YELLOW GREEN View of the Outdoor Unit Air Inlet E ep 40
2. Air Outlet 2 Connection Valve Ja E 4 Remote control Buttons and Display ENGLISH Operating mode Remote control transmission indicator AUTO COOL DRY FAN Battery discharge indicator Turbo mode Temperature settings Suenos Air flow direction Fan speed AUTO LOW MEDIUM HIGH Time Timer settings Temperature adjustment buttons On Off button Mode selection button AUTO COOL DRY FAN Off Timer adjustment button Turbo mode button Sleep timer button Air flow swing button Fan speed adjustment button Timer on off buttons Time adjustment buttons Time setting Button Timer setting cancellation buttons E 5 E 6 Getting Started You have just purchased a multi split type room air conditioner and it has been installed by your installation specialist Your Owner s Instructions contain much valuable information on using your air conditioner Please take the time to read them as they will help you take full advantage of the unit s features The booklet is organised as follows The following figures are shown on pages 4 and 5 Indoor and outdoor units Remote control buttons and display They will help you find the buttons and understand the symbols displayed In the main part of the document you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbo
3. Switching the Unit On and Off Automatically On Off Timer You can set the timer to switch the air conditioner on and or off automatically at given times Example You wish to start cooling your room before you retum from work you decide to Switch the air conditioner on at 5 30 p m Switch it off at 11 30 p m You can set The switch on time only Theswitch off time only Both the switch on and switch off times rorr ANT Check that the current time is correct before setting the timer if it is not correct refer to page 8 for details on how to set it 1 If necessary press the On Off button 2 Select the required mode by pressing the button on the remote control one or more times until the appropriate indication appears in the above example amp 3 Press the button under the cover on the remote control Result The indication flashes The current preset time is displayed Note If you do not press a button within a few seconds the Timer function is cancelled and you must press the button again 4 To set the switch on time press the Qo Q buttons To Then Increase the time in ten minute intervals Press the A button Increase the time in one hour intervals Hold down the A button Decrease the time in ten minute intervals Press the Y button Decrease the time in one hour intervals Hold down the Y button Result AM or PM is displayed to indicate whether the setting corresponds
4. u 3 The room temperature may be too low Dust may be blocking the air filter guard refer to page 19 for cleaning instructions Check that there is no obstacle in front of the outdoor unit The fan speed does not change Check that the operating mode is set to 3 or t in the Ais mode when you press the button the fan speed changes automatically and in the mode it is set to AUTO The air flow direction does not Check that the air conditioner has been switched on if necessary change when you press the press On Off on the remote control button The timer is not correctly triggered Check that you have set the clock to the right time see page 8 Check that the timer has been programmed correctly see page 15 Odours are permeated in the room Air the room during air conditioning E 20 Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken 1 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit 2 To switch the air conditioner on press the ON OFF switch on the right side of the indoor unit Result 9 The OPERATION indicator on the indoor unit comes on The indoor unit beeps The air conditioner starts up in the most suitable mode for the room temperature 3 To switch the air conditioner off press t
5. for example press the button under the remote control flap Result The AM or PM indication flashes 2 Set the time following the instructions in Step 3 in the procedure above 3 When you are satisfied with your setting confirm the time To do so TIME press the button using a small pointed tool ball point pen for example Result The AM or PM indication stops flashing The clock starts Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control In the Automatic mode the standard temperature and the optimum fan speed is selected automatically You can adjust the standard temperature but not the fan speed 1 If necessary press the On Off button Result 4 The OPERATION indicator on the indoor unit comes on The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps portant The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after a three minute 2 If the Ae indication is not displayed at the top of the remote control press the 8 button on the remote control one or more times until it appears Result The indoor unit beeps each time you press t3 The air conditioner starts up in AUTO mode Note You can change modes at any time 3 To a
6. to a time before or after midday 5 When you are satisfied with the switch on time press fll Result The indoor unit beeps The TIMER indicator on the indoor unit lights up yellow Note If not necessary to operate the air conditioner until the set up time for starting press On Off button off The air conditioner will start up automatically when the Switch on time is reached 6 To set the switch off time press the fiffutton Result The 6 indication flashes The current preset time is displayed 7 Setthe switch off time following the instructions in Step 4 8 When you are satisfied with the switch off time press E Result The indoor unit beeps The TIMER indicator on the indoor unit lights up yellow The air conditioner will switch off automatically when the switch off time is reached Note Ifyou wish to cancel the timer refer to page 17 E 15 ENGLISH Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours Nowe If you wish to switch the unit off at a specific time refer to page 15 1 If the indication is not displayed at the top of the remote control Q press the button on the remote control one or more times until it appears 2 Press the button TURBO Result 4 The indoor unit beeps The indication is displayed The air conditioner will be cont
7. E CLIM ATISEUR EST FABRIQUE PAR DIESE KLIM AANLAGE IST FABRIZIERT VON uL ELECTRONICS Printed in Korea
8. OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES ISTRUZIONI PER L USO MANUAL DE INSTRUCOES MANUEL D UTILISATION GEBRAUCHSANW EISUNG Indoor Unit Outdoor Unit Feu OVE AXM 260VE Mcpzvae XMC26ZV MULTI SPLIT TYPE ROOM AIR CONDITIONER Cool ACONDICIONADOR DE AIRE DOM STICO SISTEMA MULTI SPLIT Refrigeraci n CONDIZIONATORE D ARIA PER PIU AM BIENTI AD UNIT SEPARATE Raffreddamento AR CONDICIONADO MULTI SPLIT Refrigerac o CLIM ATISEUR DE TYPE MULTIPLE Refroidissement RAUM KLIM AGERAT IN M EHRFACH GETEILTER AUSF HRUNG K hlen SOPOO DB68 30834B 4 ENGLISH E 2 Safety Precautions The following safety precautions must be taken when using your air conditioner 1 ake sure that the indoor unit is correctly ventilated at all times do NOT place clothing or other materials over it 2 NEVER spill liquid of any kind into the indoor unit Should this happen switch off the breaker used for your air conditioner and contact your installation specialist 3 Do NOT insert anything between the air flow blades as the inner fan may be damaged and you may be hurt Particularly keep children away from the indoor unit 4 DoNOT place any obstacles in front of the outdoor unit 5 If the remote control will not be used for a long time remove the batteries 6 Users of this product are cautioned not to attempt repair of this product at their own discretion nstead they are requested to directly contact a design
9. ated service center or the outlet at which the product was purchased 7 Ifthe supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent 8 This device must be installed according to the national electrical rules 9 Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely Contents PREPARING YOUR AIR CONDITIONER m Salety PrecautioriS eee tea re pn ied ee e D te ded e 2 m View of the Indoor Unit eese entm 4 m View of the Outdoor Unit a 4 m Remote Control Buttons and Display esee 5 m QGetting Started eaa e etae hn ied coe e a ds 6 m Installing the Remote Control Holder on the Wall 7 m Inserting the Remote Control Batteries 7 m Setting the THme siu sec ete te YE Dec ERR anteaters aan eerte t 8 OPERATING YOUR AIR CONDITIONER m Selecting the Automatic Operating Mode 9 m Cooling Your Room L iR rc REO RHET IS 10 m Changing the Room Temperature Quickly ssssssseese 11 m Removing Excess Humidity 1 e 12 E Airing YOur ROO a nee een tx be FEPTEM vielen ER pus 13 m Adjusting the Air Flow Direction Vertically eeenn 14 m Adjusting the Air Flow Direction Horizontally
10. currently set The air conditioner operates normally TIME Gee g 7T geo PCE Cancelling the Sleep Timer If you no longer wish to use the Sleep Timer that you have set you can cancel it at any time EUR Press the button Result The indoor unit beeps mg The indication is no longer displayed The air conditioner operates normally Em o EE Cancelling the Quick Timer If you no longer wish to use the Quick Timer that you have set you can cancel it at any time Press the ES button one or more times until the current time indication is Q displayed Result The indoor unit beeps each time you press 9 The air conditioner operates normally Gove TURBO E 17 Operating Recommendation Here is a recommendation that you should follow when using your air conditioner Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns you must press On Off to restart it Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used If the air conditioner is used at Then High temperatures The automatic protection feature may be triggered and the air conditioner stopped Low temperatures A water leakage or some other malfunction may happen because the heat exchanger freezes High humidit
11. djust the standard temperature The air conditioner automatically set the standard temperature by the current room temperature press the or buttons one or more times SET TEMP SET TEMP SET TEMP SET TEMP 2 C 1 C Standard temperature 1 G 2 C 2 92 Co 2 lt When you feel hot gt lt When you feel chilly gt amo TEMP fo v el L c E 9 ENGLISH Cooling Your Room You must select the Cool mode if you wish to adjust the Cooling temperature Fan speed when cooling 1 If necessary press the On Off button Q Result The OPERATION indicator on the indoor unit comes on The air conditioner starts up in the mode selected when g the unit was last used Gone Tuna or The indoor unit beeps The air conditioner is fitted with a protection mechanism to G rorranr prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after a three minute 2 If the indication is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press q The air conditioner starts up in Cool mode Note You can change modes at any time 3 To adjust the temperature press the O s buttons one or more times until the required temperature is displayed Possible temperatures are bet
12. he ON OFF switch again Note Even if the air conditioner has been switched on via the ON OFF switch operations can still be controlled using the remote control as usual E 21 ENGLISH Installing a Filter Option The air conditioner can be fitted with a deodorizing and Bio pure filter to remove minute dust particles or odours The service life of the filter is approximately three months depending on the time during which the air conditioner is used 1 Remove the vinyl packing from the filter Note Do not remove the packing from a deodorizing filter until you oe wish to use the filter as it will lose its properties iter 2 Insert the filter in the filter holder and press the three insert tabs until you hear a click Bio pure 3 Open the front grille by pulling on the tabs on the lower right and left filter sides of the indoor unit 4 Take out the existing filter and replace it with the new one Air purifying system Model Deodorizing and Indoor unit Electro static filter ASMO70VE MCO07ZV 26 Option The unit can be attached ASM120VE with a commercially MC12ZV 26 Technical Specifications Model Indoor unit Power Supply ASMO70VE ASM120VE MCO07ZV 26 MC12ZV 26 220 240V 50Hz E 22 IDERE E 23 THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR QUESTO CONDIZIONATORE D ARIA E PRODOTTO DA ESTE APARELHO DE AR CONDICIONADO E FABRICADO POR C
13. it beeps 4 To control the direction of the air flow refer to page 14 E 13 ENGLISH Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room you can adjust the position of the outer air flow blade on the bottom of the unit thus increasing the efficiency of the air conditioner 1 Press the E button under the remote control flap one or more times as required Result The outer blade is adjusted vertically RECOMMENDATION When Adjust the blade to face Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is operating press the GBP button Result The blade move up and down around the base position set 3 To stop the blade moving up and down press the GPobutton again Note If you switch the air conditioner Then the blade is Off Closed completely On again Reset to the position that you previously selected Adjusting the Air Flow Direction Horizontally There are two sets of inner air flow blades J ust as the outer air flow blade can be adjusted vertically the inner blades can be adjusted horizontally 1 Open the air flow blade along the bottom of the indoor unit by pressing the ff9ll button 2 To stop the blade moving up and down press the fllouton again 3 Adjust each set of inner blades to the required position by pushing or pulling them sideways E 14
14. ls i HOLD DOWN Installing the Remote Control Holder on the Wall The remote control is supplied with a plastic holder that can be fitted to the wall to hold the remote control when you are not using it To attach the holder to the wall proceed as follows ENGLISH 1 With a pencil mark the positions of the two holes on the wall where the holder is to be installed 2 Drill the two holes and insert plugs as required for the type of wall on which the holder is being installed 3 Screw the holder into position Result You can now slide the remote control in and out of the holder as required Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly Note Use two LRO3 1 5 V batteries Do not use old batteries or different kinds of batteries together Batteries may be completely discharged after 12 months even if they have not actually been used 1 Slide the remote control out of its holder 2 Push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it 3 Insert the two batteries taking care to respect the polarities onthe battery with on the remote control onthe battery with on the remote control 4 Close the cover by sliding it back until it clicks into place E 7 Setting the Time Your air condi
15. ous mode temperature and fan setlings but if you press the Ezzlbutton in 4 or cf mode that is changed with fc mode automatically 3 If you wish to stop the Turbo function before the end of the 30 minute period press the Wf button again Result The air conditioner is reset automatically to the previous mode temperature and fan settings but if you press the Ezlbutton in 4 or cf mode that is changed with att mode automatically 4 Tocontrol the direction of the air flow refer to page 14 ENGLISH TEMP ak Ai TURBO Lc R n a ra cst E 11 Removing Excess Humidity emp e lt o L alc o r e CES ED E 12 If the atmosphere in your room is very humid or damp you can remove excess humidity without lowering the room temperature too much 1 If necessary press the On Off button Result 4 The OPERATION indicator on the indoor unit comes on The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps Gprorrant The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped It will start up normally after a three minute 2 Ifthe indication is not displayed at the top of the remote control press the amp 3 button on the remote control one or more times until it appears Result The indoor unit beeps each
16. rolled as indicated in the illustrations below Cooling The temperature is increased by 1 C every hour When it has been increased by 2 C after two hours the Set temperature is maintained for P IEMP f h Start Stop our hours time time Setting the Quick Timer The Quick Timer enables you to set the air conditioner to switch off automatically after a given period of time by pressing one single button The unit can be switched off automatically after 30 minutes one hour two hours three hours or five hours Note If you wish to switch the unit off at a specific time refer to page 15 1 If necessary switch the air conditioner on and select the required E mode m 2 deg j Ic 2 Press E one or more times until the correct period is displayed PCT S CD s eI s enm PD PAP sequ oy LO ee ee I gt oT m m Lg ibt Result The TIMER indicator lights up yellow The air conditioner will switch off automatically when the counter displayed on the remote control reaches FU E 16 Cancelling the On Off Timer If you no longer wish to use the On Off Timer that you have set you can cancel it at any time 1 To cancel the Then press Switch on timer a Result The indication flashes Switch off timer Result The indication flashes 2 Press the button Result 4 The indoor unit beeps The TIMER indicator on the indoor unit switches off if no other timer is
17. the front grille lift up to the max push slightly to the left and pull down to release them and vice versa ENGLISH ya Front grille I Body groove E 19 Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call Problem Explanation Solution The air conditioner does not Check that the breaker used for the air conditioner is switched on operate at all Check that the OPERATION indicator on the indoor unit is on if necessary press On Off on the remote control Check whether the TIMER indicator on the indoor unit is switched on If so Wait until the switch on time is reached and the air conditioner starts up automatically Cancel the timer see page 17 for further details The air conditioner does not operate with the remote control Check that there are no obstacles between you and the indoor unit Check the remote control batteries Check that you are close enough to the indoor unit seven metres yards or less 99 No beep is heard when you press Check that you are pointing the remote control at the infrared sensor On Off on the remote control in the middle of the indoor unit Replace the remote control batteries if necessary The air conditioner does not cool Check that the correct operating mode has been selected
18. time you press t3 The air conditioner starts up in Dry mode Note You can change modes at any time To adjust the temperature press the Qo Q6 buttons one or more times until the required temperature is displayed Possible temperatures are between 18 C and 30 C inclusive Result Each time you press Q0 The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts removing the excess humidity the quantity of air is adjusted automatically 4 To control the direction of the air flow refer to page 14 Airing Your Room If the atmosphere in your room is stale you can air the room using the Fan feature 1 If necessary press the On Off button Result The OPERATION indicator on the indoor unit comes on The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps 2 If the indication is not displayed at the top of the remote control press the button on the remote control one or more times until it appears Result The indoor unit beeps each time you press Gq The FAN indicator on the indoor unit lights up The air conditioner starts up in Fan mode The temperature is set automatically Note You can change modes at any time 3 Select the fan speed by pressing the Ebutton one or more times until the required setting is displayed Low e Medium Jefe High Result Each time you press the indoor un
19. tioner contains a clock used to start and stop the unit automatically at a given time You must set the time when you Purchase the air conditioner Replace the batteries Note Be sure to reset the time when you change clocks from standard todaylight savings time and vice versa Setting the Time for the First Time 1 Insert the batteries Push the battery cover on the rear of the remote control with your thumb and remove it Result The clock starts TIME 2 Using a small pointed tool ball point pen for example Press the button Result The AM indication flashes B BEB 3 To set the current time press the f or Q buttons under the cover on the remote control To Then Increase the time in one minute intervals Press the A button Increase the time in ten minute intervals Hold down the A button Decrease the time in one minute intervals Press the W button Decrease the time in ten minute intervals Hold down the W button Result AM or PM is displayed to indicate whether the setting corresponds to a time before or after midday 4 When you are satisfied with your setting confirm the time To do so using a small pointed tool ball point pen for example press the button Result The AM or PM indication stops flashing The clock starts Resetting the Time If you have already set the time but wish to change it proceed as follow 1 Using a small pointed tool ball point pen
20. ween 18 C and 30 C inclusive Result Each time you press Q0 The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts cooling provided that the room temperature is higher than the selected temperature the fan will however operate 4 Select the fan speed by pressing the E button one or more times until the required setting is displayed Low ff Medium eff High Automatic Result Each time you press the indoor unit beeps 5 To control the direction of the air flow refer to page 14 E 10 Changing the Room Temperature Quickly The Turbo cooling function is used to cool your room as quickly as possible Example You have just come home and find that the room is very hot You wish to cool it down as quickly as possible The Turbo function operates for 30 minutes with the maximum settings before retuming automatically to the mode and temperature previously selected 1 If necessary press the On Off button Result The OPERATION indicator on the indoor unit comes on The air conditioner starts up in the mode selected when the unit was last used The indoor unit beeps 2 Press the E button Result The temperature and fan settings are adjusted automatically The TURBO indicator on the indoor unit lights up The air conditioner cool the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previ
21. y levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods Mode Outdoor Temperature Indoor Temperature Indoor Humidity Cooling 21 C to 43 C approx 18 C to 32 C approx 80 or less Drying 18 C to 43 C approx 18 C to 32 C approx x Ifthe cooling operation is used at over 33 C indoor temperature then does not a full capacity Cleaning Your Air Conditioner To get the best possible use out of your air conditioner you must clean it regularly to remove the dust that accumulates on the air filter prorta NT Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit 1 Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit 2 Lift out the bottom edge of the air filters and pull down to release them 3 Remove all dust on the air filters with a vacuum cleaner or brush 4 When you have finished insert the top part of the filters into their slot and push down on the bottom edge until they click into place 5 Clean the front panel with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals Nor If you have not used the air conditioner for a long period of time set the fan going for three to four hours to dry the inside of the air conditioner thoroughly The removal of the front grille facilitates your cleaning the air conditioner After opening