Home
Royal Consumer Information Products G31 User's Manual
Contents
1. elderly and infirm Combustible materials should not be put on or left in the hearth nor should the coal bed be used to burn rubbish or other materials Care must be taken on the selection of wall coverings within close proximity of the fire as some vinyl and embossed materials may be become discoloured by convected heat Soft furnishings must be kept clear from the radiant heat of the fire and from impinging the hearth area The hearth must not be covered by any combustible materials such as carpets etc This product uses fuel effect pieces gaskets and insulation material containing Refractory Ceramic Fibre RCF which are man made vitreous silicate fibres Excessive exposure to these materials may cause temporary irritation to eyes skin and respiratory tract consequently it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum This fire will run for 2 2 hours on one kilogram of gas with the gas control on the high setting Page 2 One type of fire front and fret suggested is shown in Fig 1 this has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes If other fronts and frets are to be used they must have a minimum open area in the fret of 20 sq cms and 60 sq cms in the front See Fig 1 This appliance is fitted with an Oxy pilot which in the event of the flue being blocked or hazardous conditions causing the applia
2. It is important when relaying the coal bed and coals to follow the instructions correctly TECHNICAL DATA TYPE OF GAS G31 only SETTING PRESSURE 37 mbar 1 mbar cold GAS INPUTS Gross Max 6 kW 20470 Btu h Min 3 5 kW 11940 Btu h Pilot 0 26 kW 890 Btu h IMPORTANT NOTES This appliance is intended for decorative purposes it is designed and manufactured to the requirements of the BS 5258 Pt 16 1991 and is for use on Propane Gas Only All gas appliance installations must be carried out by a competent person in accordance with the Gas Safety installation amp Use Regulations 1994 as amended or the rules in force and in accordance with the Manufacturers Installation Instructions Failure to comply could lead to prosecution The chimney or flue unless new must be swept before installation It is recommended that the appliance be serviced annually by a competent person and that the flue is checked for satisfactory clearance of products and there is no excessive build up of soot The curing effect of heating the coals will cause an initial odour which although not harmful may require additional ventilation until the odour has disappeared Ventilation is required for this appliance with a minimum cross sectional area of 100 sq cms and should be checked regularly to ensure that it is free from obstruction The appliance has a naked flame a fireguard conforming to BS 6539 or BS 6778 should be used for the protection of the very young
3. Screws Adjusting screw Fig 9A Lock nut to secure aN Fig 8A 45 Restrictor plate Fixing Holes Fig 9 Wire bond 2 screw eyes fixed to the rear of the opening with plugs 4 Knock out holes Solderless nipple Page 12 Fig 11 Coal Support Shelf L amp R Hand A xd rt df TA aih Simulated Front Coal a eS lt lt aa g 4 a oN Fig 12 Page 13 s 3 5 5 5mm i Fig 14 X PANE 7 No Figures 13 amp 15 f i ia On this page Adh amen rh Requirements for ventilation of alternative Fionts amp Frets Fig 16 A Minimum ventilated area of 60sq cms at a higher level Minimum ventilated area at low level e g Fascia height of 20 sq cms Short Parts List ina Fi tact th facturer at the teleph ber sh w or spares contact the manufacturer e telephone number shown Fig 17 mana LJ a eae t Ident Descnpton il Coal Support L amp R Hand 42587 12 Front Simulated Coal 42769 23 Control Knob 24 Piezo Igniter 25 Oxy Pilot Bumer Assembly 42282 Control Valve Main Injector Set of Coals Crosslee No 40232 40245 42143 43112 0102 078 01361 Page 14 Registration Record Purehasets Name ose 2 eccsccs iertics cece cecececccurectcececesesad cacicececesseutunstii Stee and Address Sabi hedcddhcidbsadiccdexddieddinadinidencdeedewadisid
4. and the simulated coal front Fig 2 Referring to figures 2 3 and 4 lay the coals as follows l Place 4 large round coals between the simulated coal front and the support shelf Fig 3 2 Place 3 round coals between the gaps in the front row Fig 3 3 Place the 5 small round coals between the gaps formed in the coals laid in 1 amp 2 above Fig 4 Cleaning the Front of the Appliance The fire must be turned off and allowed to cool The paintwork should be cleaned with a soft cloth or soapy water the brass trim has a clear lacquer coating to preserve the polished finish Spares and Service For spares and service contact your local supplier installer or direct to the manufacturer stating that the appliance is a Slimline De Luxe and quoting the serial number from the data label located on the fascia panel Advantage should be taken of regular servicing and inspection of gas appliances to ensure their continued safe operation Short Parts List Description Crosslee Pt No Coal Support Shelves 42587 Front Simulated Coal 42169 Set of Coals 0102 078 01361 Requirements for Ventilation of alternative Fronts amp Frets Fig 1 Minimum ventilated area of MAE 5 60 sq cms at high level Minimum ventilated area at low level e g Fascia height of 20 sq cms Page 4 Coal Support Shelf L amp R hand 3 K X DSi a Coal front J T A f Piezo Igniter i N i Isolati
5. secure into position with the 2 x No 8 self tap screws supplied complete the gas connection Note The complete installation should be tested for Gas soundness Fit the brass trim in position and remove the plastic coating from the brass finish Laying the Coal Bed Fit the coal support shelf ensuring that the front edge sits behind the three tabs and the simulated coal front Fig 10 Referring to figures 10 11 12 and 13 lay the coals as follows l Place 4 large round coals between the simulated coal front and the support shelf Fig 12 2 Place 3 round coals between the gaps in the front row Fig 12 3 Place the 5 small round coals between the gaps formed in the coals laid in 1 amp 2 above Fig 13 Checking Operation of Fire Turn on the Gas supply at the meter and to the appliance at the isolating cock Purge the air to the appliance Rotate the control knob to the ignition position depress the control and push the piezo to ignite the pilot Check that the electrode is sparking between the tip of the thermocouple and continue until a pilot ignition is established Depress the control knob slightly and rotate anti clockwise until the index symbol is aligned with the small flame symbol on the indicator label Release and rotate the control knob to the high position large flame symbol and check that the flame picture is satisfactory then release the control knob if the pilot does not stay alight repeat until the pilot remains aligh
6. 0102 095 50261 CE SLIMLINE STANDARD USERS INSTRUCTIONS THIS CAT lp APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB amp IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required This appliance is intended for decorative purposes the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure clean combustion An aerated single port steel burner is used running parallel across the front of the fire A single gas control with a variable high to low setting is used with a Flame Supervision Device FSD This is fitted to ensure that should the pilot flame be extinguished for any reason including turning off the appliance the gas supply to the burner is cut off until a full lighting sequence is repeated A separate Piezo igniter is used to ignite an Oxy Pilot sensor ODS which will cause the appliance to shut off in the event of continued spillage occurring under hazardous or blocked flue conditions The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required
7. Cold GAS INPUTS Gross Max 6 kW 20470 Btu h Min 3 5kW 11940 Btu h Pilot 0 26 kW 890 Btu h Main Injector Type Stereomatic 046 19 196 047M Pilot OP Oxy Pilot 1PG 9214 GAS CONNECTION 8mm O D Tube WEIGHT 11 5 kg without front amp fret 14 5 kg with front amp fret Page 2 Installation Regulation and Requirements The appliance must be installed by a competent person in accordance with the current Gas Safety Installation and Use Regulations 1994 as amended or the rules in force and in accordance with the manufacturers instructions failure to do so could lead to prosecution The following are the relevant Codes of Practice and British Standards The Building Regulations issued by the Department of the Environment The Building Standards Scotland Consolidation Regulations issued by the Scottish Development Department BS 8303 1986 BS 5440 Pt1 1990 amp Pt2 1989 BS 1251 1987 BS 5871 Pt2 1991 amp Pt3 1991 BS 6891 1988 BS 6461 Ptl 1984 BS 715 1993 BS 1289 Ptl 1986 BS 7566 Pts 1 4 1992 Important Notes Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very young elderly and infirm a fireguard conforming to BS 6539 or BS 6778 be used The type of front and fret recommended is shown in this instruction it has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes If other fronts a
8. TOR PLATE MUST NOT BE USED WITH 5 OR PRE CAST FLUES The restrictor is for use with 7in 175mm diameter flues only The appliance is supplied without a Flue Restrictor fitted in position 1 e suitable for 5 or pre cast flues The restrictor plate is fitted prior to installing the firebox and is held in position with the two self tap screws provided See Fig 9 Page 5 Installing the Appliance in Position When the gas supply pipe has been laid to the position required the surround should be fitted and sealed to the chimney correctly This is to prevent any seepage of flue products or to prevent any ingress of air into the flue from anywhere other than the flue outlet of the fire The easier method of installation is through the holes provided in the front face of the vent box this method will require drilling into the back panel of the surround See Fig 8 Where it is undesirable to deface or damage the back panel a cable fixing kit is provided which can be fastened to the inner walls of the opening and the back of the box see Fig 9 Before offering the vent box into the opening the hearth should be protected from damage or scratches that may occur during installation Locate and secure the firebox by the method chosen ensuring that a good seal exists with the back panel Lay a gas supply to the location of the burner connecting elbow and place the burner into the vent box locate the facia panel cut out over the flange on the baseplate and
9. advisable to provide a means of isolating the gas supply to the appliance for servicing using the isolation cock supplied Provision is made i e knock out blanks for entry into the box in both L amp R hand rear corners and at the L amp R hand sides although for ease of installation it is recommended that the gas feed is made from the left hand side Any pipe used under the tray must be in rigid tube such as bundy suitable pieces of bundy are included in the fitting kit to assist the installer Where a concealed gas supply is used the installer is reminded of the requirements of BS 6891 1988 dealing with enclosed pipes The Standard requires that when a gas pipe is fed through a wall the pipe should be enclosed in a tight sleeve to protect against failure caused by movement and shall be constructed to prevent passage of gas either between the pipe and sleeve or sleeve and wall Where a gas supply pipe enters the box in any of the positions stated the hole around the pipe should be sealed with a silicone sealant or similar to prevent ingress of air into the flue Permanent sealant e g fire cement etc should not be used as these would prevent removal of the firebox if so required Dismantling the fire prior to Installing It will be necessary to dismantle the burner from the firebox before installing the box in the opening To remove the burner unscrew the two screws on the front flange of the burner lift and pull forward Important THE RESTRIC
10. appliance goes out for any reason wait for three minutes before attempting to relight Dismantling the Fire Bed for Cleaning Allow the appliance to cool for 1 hour before handling any components Remove the coals lift off the simulated coal front and the coal support shelf Take out the lower fibre back and side cheeks Once all the fibre components have been removed from the firebed check that no debris has fallen in or lodged the burner slots both front and rear If any debris is present it may be easily removed by using a small piece of thin cardboard to ease out any foreign matter Be sure to remove the cardboard after use Should any soot accumulation become excessive the fuel effect pieces should be removed from the fire for cleaning Cleaning should be carried out in a well ventilated area or in the open air by gently brushing with the pieces held away from your face so that you avoid inhaling the dust We do not recommend the use of a normal domestic vacuum cleaner which may blow dust back into the air Any sooty deposit on the thermocouple probe can be cleaned of using a non fluffy cloth Page 3 It is very important that the coals and the coal bed components are laid as shown no extra coals or material may be used If any of the items become lost or damaged replacements must be obtained before further use of the appliance Relaying the Coal Bed Fit the coal support shelf ensuring that the front edge sits behind the three tabs
11. eeceeeddebdvanateloieieioese UD PHEES NAMIC ea ae a eE E E E EE E R and Address ee e R E A nE Installer s Name fk a E Euit and Address lt sececisevesecccezicevivesenetcedioostearsanedeadtoosseansuesteedteestaarioonteeess Date of Purchase ccccccceeeeseeeees Serial No ou Please return this section with any components that fail under guarantee Maximum Heat Input 6 kW 20470 Btu h Gross Royal Cozyfires are manufactured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 50p per minute
12. he metal flue box should be enveloped with insulation material such as rockwool or similar to prevent build up of heat within the structure the top surface of the flue box must have a minimum of 25mm of insulation material under all conditions It is important that both the back panel and the apphance are sealed to the metal flue box to prevent any leakage of the flue products or reduction of the flue draught oe Fig 3 The hatched are must be a non combustible material and flat to ensure a seal around the appliance 1 r 4 365 Praias s 400 450 615 at a me a 75mm ar gap 25mm insulated r Care must be taken to ensure the flue spigot of the appliance does not impede the flue outlet of the metal flue box Fig 4 The area beneath the metal flue box must be a non combustible material 25mm thick ae Page 10 Pre cast Flue Installations we a 400 450 a Important The flue restrictor plates must not be used Surround thickness when flue outlet depth is maintained Ensure that the flue outlet does not protrude into flue f advantageous to chamfer If the edges of the opening to increase the depth available A Depth or thickness of the Back panel required to ensure a seal with the appliance Fig 7 Page 11 Surround Back Panel oF Screw ane Hearth Fixing
13. ing If there is a connected room the test should be repeated with all the doors in that room opened Demonstrate the lighting and extinguishing procedures to the user Advise that The curing effect of heating the coals will cause an initial odour which although not harmful may require additional ventilation until the odour has disappeared Any debris or soot is cleaned from the appliance Advise the customer that they should read their Users Instructions before operating the fire and always follow the advice in the section headed Removal of Debris or Soot Deposits The appliance must be serviced annually by a competent person in accordance with these instructions at this time the appliance should be re checked for spillage in accordance with the method detailed in these instructions If the appliance is turned off or shuts off automatically wait for at least 3 minutes before attempting to relight The appliance is fitted with an Oxy pilot to prevent the continued operation in the event of spillage occurring If the fire shuts OFF repeatedly the appliance must be turned off and not used until an expert is consulted Complete the registration section at the end of this booklet Advise that any component part of this appliance be guaranteed against defective workmanship or faulty materials for a period of twelve months from the date of purchase Any such part will be replaced free of charge on receipt of the purchasers add
14. iting assembly to withdraw control from the mounting bracket Replace in reverse order iii TO REPLACE THE PIEZO IGNITER Pull off the HT lead from the rear of the igniter Retain the metal fixing nut with one finger and rotate the body of the igniter to unscrew Withdraw the igniter from the front Replace in reverse order and reconnect the HT lead iv TO REPLACE THE OXY PILOT ASSEMBLY The assembly is not an item that can be serviced as part of its calibration depends on the proximity of the spark electrode and thermocouple tip The assembly can be replaced by removing the tube nut and tube from the base of the pilot and the thermocouple from the FSD also the igniter lead and the two screws securing the bracket to the framework Replace in reverse order the spark gap is shown in fig 14 Page 8 Hatched area must be non combustible x and flat to ensure a seal around Pee the appliance Fig 2 Depth A is to be a minimum of 150mm from the knee to the front face of the surround with the sapcer fitted to satisfy the debris collection requirement _ Depth B 1s normally 70mm If no charbrick is fitted the minimum distance required between the rear of the opening and the front face of the surround is 210mm without spacer frame fitted Page 9 Installation using a 5 Diameter Metal Fluebox r When the metal fluebox is to be built in as a false chimney breast using the timber stud work with a plasterboard facing t
15. ling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or drinking Any sooty deposit on the thermocouple probe can be cleaned off using a non fluffy cloth DO NOT USE ABRASIVE MATERIALS B SERVICING COMPONENTS BELOW THE BURNER ASSEMBLY Turn OFF the gas supply to the appliance Remove coals coal supports burner inserts and front simulated coal To gain access to components below the burner assembly it has to be removed from the vent box case by disconnecting the gas supply at the inlet elbow and unscrewing the two screws on the sides of the facia panel Where the supply is fed from the right hand side across the front of the fire it will be necessary to disconnect the supply from the isolation tap elbow 1 TO CLEAN OR REPLACE THE INJECTOR Remove the aeration sleeve retaining screw unscrew the compression nut connecting the gas supply to the elbow injector while supporting the injector to prevent distortion of the framework Unscrew and remove the gas supply tube from the gas control valve hold the injector lock nut with a spanner and rotate the injector Replace in reverse order ensure the aeration sleeve retaining screw is replaced ii TO REPLACE THE GAS CONTROL Tap FSD Disconnect the three gas pipes and the thermocouple from the control Pull off the knob and lay to one side Undo the retaining nut at the front of the tap n
16. nce to spill products of combustion will shut OFF the gas supply to the appliance If the sequence is repeated the appliance must be turned OFF and not used until expert advice has been obtained Clearance to Side Minimum clearance required to any combustible material to the side of the appliance must be 150mm Clearance to Shelves Minimum clearance to the underside of a 150mm deep combustible shelf from the hearth must be 790mm add 12 5mm to this dimension for every 25mm increase in the depth of the shelf To light the appliance Remove the fret controls cover to gain access Press and turn the gas control knob anti clockwise until the indicator dot is opposite IGN Keep the gas control fully depressed Press and release the piezo igniter until the pilot flame situated in the centre behind the simulated coal front has lit Keep the gas control depressed for a further 10 to 15 seconds Release the gas control and check that the pilot flame remains lit Refer to Fig 2 to view pilot Note For convenience the unit can be operated with the pilot only i e with the control knob set in the IGN position Push in the gas control slightly and turn anti clockwise so that the indicator dot is at the required setting Replace the fret controls cover To turn off the appliance and pilot turn the gas control clockwise from any position until the indicator dot is opposite OFF IMPORTANT After turning OFF or if the pilot and the
17. nd frets are to be used they must have a minimum open area in the fret of 20 sq cms and 60 sq cms in the front Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e g many embossed vinyl wall coverings may become discoloured if located too close to the appliance Clearances required for combustible shelves are shown in fig 1 Care should be taken to ensure that when the appliance is installed into a Pre cast flue the chimneybreast is lined to prevent the plaster etc cracking through excessive temperatures A hearth must always be provided to project forward of the opening a minimum of 340mm depth and 150mm either side of the fire opening The hearth must be a minimum thickness of 12mm with a perimeter height of 50mm to deter combustible materials carpets etc being placed on the hearth The area under the firebox must have a minimum non combustible thickness of 25mm In most installations a back panel will be required this will also need a minimum fire resistance rating of Class 0 100 C Ventilation is required for this appliance with a minimal cross sectional area of 100 sq cms and should be checked regularly to ensure that it is free from obstruction The chimney or flue unless new must be swept before installation It should be checked annually when the appliance is serviced for spillage smoke test and that there is no excessive build up of soot Page 3 Fire Surround and Ope
18. ning Requirements Check that the chimney and flue structure are sound and conform to the following flue requirements a A conventional brick or stone chimney with a minimum effective cross sectional dimension of 225x225mm A lined flue with a minimum diameter of 175mm having a chairbrick and throat forming lintel conforming to BS 1251 or a builders opening measuring 560mm high x 400mm wide with a depth of 185mm minimum for debris collection If a chairbrick is fitted a minimum depth requirement for the fire is shown in fig 2 b A twin walled metal flue box manufactured to BS 715 with a twin walled 125mm diameter flue and a minimum effective height of 3 metres See figs 3 amp 4 c A pre cast flue conforming to the requirements of BS 1289 Pt 1 1986 and BS 1289 1975 including properly constructed pre cast flues with a cross sectional area of 13000sq mm See figs 5 amp 6 Important Dampers register plates or incorrect flue terminals must not restrict any of the above flues The flue must only service a single appliance and not have any branches or traps that may impede the natural draught Any flue damper plate or restrictors shall be removed or fixed in the fully opened positions The front and base of the fire opening must be flat and square to ensure a good seal with the appliance this is to ensure that there is no reduction in draught through the fire that may cause spillage to occur Clearance to Side timber surrounds etc Minimum clea
19. o be entrained into the bed to ensure clean combustion An aerated single port steel burner is used running parallel across the front of the fire A single gas control with a variable high to low setting is used with a Flame Supervision Device FSD This is fitted to ensure that should the pilot flame be extinguished for any reason including turning off the appliance the gas supply to the burner is cut off until a full lighting sequence is repeated A separate Piezo igniter is used to ignite an Oxy pilot sensor O D S that will cause the appliance to shut off in the event of continued spillage occurring under hazardous or blocked flue conditions The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required It is important when relaying the coal bed and coals to follow the instructions correctly This appliance is suitable for installations into the following flues 7 minimum diameter flues CLASS 1 5 minimum diameter flues CLASS 2 Pre cast flues to BS 1289 Pt 1 1986 The installations must always be used in conjunction with a suitable hearth and surround TECHNICAL DATA Overall height of fire 602 mm Overall width of fire 505 mm Minimum height of opening required 550 mm Minimum width of opening required 396 mm Forward projection from opening 50 mm without front amp fret Depth behind opening 122 mm TYPE OF GAS G31 Only Supply Pressure 37 mbar Imbar
20. on cock Control Knob Fig 2 l Pressure Test point Fig 3 Page 5 REGISTRATION RECORD Purchaser s Name and Address Supplier s Name and Address Installer s name and Address Date of Purchase Serial Number Please return this section with any components that are faulty under guarantee MAXIMUM HEAT INPUT 6 kW 20470 Btu h Gross Royal Cozyfires are manufactured by CROSSLEE plc Aber Park Industrial Estate Aber Road Flint Flintshire CH6 5EX Spares Tel 01422 203963 Fax 01422 204475 Service GSA Ltd 01703 516611 Customer Service 01422 200660 Fax 01422 206304 Technical Help Line 0906 8633268 Calls charged at 50p per minute 0102 095 50251 CE SLIMLINE STANDARD INSTALLATION and SERVICING INSTRUCTIONS THIS CAT lp APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB amp IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required This appliance is intended for decorative purposes the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air t
21. rance required to any combustible material to the side of the appliance must be 15Omm Fig 1 Clearance to Shelves Minimum clearance to the underside of a 15Omm deep combustible shelf from the hearth must be 790mm Add 12 5mm to this clearance for every 25mm increase in depth of shelf Fig 1 Contents Check List Fire Box Assembly c w Burner Assembly Coal Pack including Brass Trim Coal pack A 5 Small Coal Support Shelf Coal Pack B 7 Large Simulated Coal Front Fitting Kit Screws amp Wall Plugs Cable Kit Isolation Elbow Bundy Installation and Servicing Instructions Users Instructions Page 4 Installation of the Appliance Check that the chimney conforms to the required specifications as previously stated Examine the condition and carry out any remedial work as necessary if the flue has been used for solid fuel it should be swept and a smoke test carried out to check that satisfactory smoke clearance has been established If all the smoke is not drawn into the flue pre heat the flue with a blowtorch or similar and re check If there is any uncertainty examine for the cause and if necessary seek expert advice Gas Supply BEFORE COMMENCING WORK TURN OFF ANY APPLIANCES THAT ARE FED BY THE SUPPLY AND ISOLATE THE GAS SUPPLY BY TURNING OFF AT THE SUPPLY The gas connection to this appliance is made with 8mm o d rigid or semi rigid tube to a pressure test elbow situated on the L H side of the burner as shown in Fig 10 It is
22. ress at the cost of postage only provided that a It is accompanied by the registration section cut out of the booklet together with the original purchase receipt which will be returned with the replacement part b A competent person has carried out any installation repairs or adjustments such as the supplier s representative or a CORGI registered installer Page 7 Maintenance and Servicing GENERAL A REMOVAL OF DEBRIS OR SOOT DEPOSITS Allow the appliance to cool sufficiently before removing all of the coals and firebed components for cleaning purposes Once all the ceramics are removed from the firebed check that no debris is located in the burner slots both front and rear If any debris is present it may easily be removed by using a small piece of thin cardboard to ease out any foreign matter Be sure to remove the cardboard after use To ensure that the release of fibres from these RCF articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when hand
23. t with the knob released Turn the gas control to the OFF position wait for 90 seconds fully depress the gas control turn to the ignition position and release the control Attempt to light the pilot with an already prepared match or taper if the pilot lights the FSD is faulty Page 6 To check the gas pressure at the appliance allow the coals and the coal bed to cool and turn off the gas supply at the isolating cock Remove the hexagon headed screw and connect a manometer to the pressure test point turn on the gas and ignite the fire allow to heat up and check that the gas pressure is 37 mbar 1 mbar any appreciable drop may indicate restrictions through the pipework up to the fire The pressure test point may also be used to check for leakage of the joints to the appliance Allow the coal bed to cool before replacing the screw Spillage Check Light the appliance and set to the large flame position locate the front and fret in position and leave to warm up for 5 minutes Check for satisfactory clearance of combustion products by positioning a lighted smoke match 20mm down from edge of canopy 80mm from either side and 45mm back from the front edge All the smoke must be drawn into the flue see Fig 8A If spillage occurs allow a further 10 minutes Should spillage still occur disconnect the appliance and examine the chimney for the fault and rectify If an extractor fan is situated in the room the test should be repeated with the fan runn
Download Pdf Manuals
Related Search
Related Contents
Franke FTT 6122 XS Macintosh用セットアップシート Thermo Scientific HyClone Single-Use Bioreactor (SUB) User`s Guide Manual do Utilizador do Nokia X2-05 LF564 Manuel d`utilisation Benutzerhandbuch Deutsch STG 1000 BSW Samsung DVD-R130 راهنمای محصول Natural Shine.indd Crossroads Manual 18-1822-A Copyright © All rights reserved.
Failed to retrieve file