Regency P121RC-NG User's Manual
Contents
1. RN GENEE EN Qu Mo ARAB lau e e Gas Burner OFF To TH m B er a In To Thermocouple IN S T Valve e er Remote Receiver or Thermostat Millivolt Optional Remote Transmitter Optional CAUTION Label all wires Terminal Block Location prior to disconnection when servicing controls Wiring er rors can cause improper and dangerous operation Remove cover to access Terminal Block 28 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the ap pliance with the glass removed 5 Verify that the flueing and cap are unob structed 6 Ensure that the brick panels are installed 7 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positioned 8 The unit should never be turned off and on again without a minimum of a 60 second wait Hi Lo Pilot Adjustment LIGHTING PROCEDURE 1 Push in gas control knob slightly and turn to PILOT position 2 Push in control knob
2. ua 1 Maintain the 1 1 4 clearances air VERTICAL TERMINATION spaces to combustibles when passing through ceilings walls roofs enclosures attic rafter or other nearby combustible surfac es Do not pack air spaces with gt insulation Check pages 17 19 for the maximum vertical rise of the flueing system and the maximum horizontal offset limitations 4 Assemble the desired lengths of pipe and elbows Ensure that all pipes and elbow connections are in the fully twist locked position and sealed Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole should be of sufficient size to meet the minimum requirements for clearance to com bustibles of 1 1 4 Slip the flashing under the shingles shingles should overlap half the flashing as per Diagra
3. Clearance k in mm Space Heaters All Other Appliances Up to 50 MJ h Up to 50 MJ h input Over 50 MJ h input Over 150 MJ h input input to 150 MJ h input 150 500 1000 1500 NOTES 1 For mechanical air inlets including spa blowers the clearance j and k shall be 1500 mm in all cases 1 All distances shall be measured vertically or horizontally along the wall to a point in line with the nearest par to of the terminal Ill Prohibited area below electricity meter or fuse box extends to ground level IV A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved 12 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION FLUEING ARRANGEMENT HORIZONTAL TERMINATIONS Regency Direct Vent System Flex Horizontal Terminations Only These flueing systems in combination with the P121 P121LC P121RC P131 Direct Vent Gas Fireplace have been tested and listed as a direct flue heater system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 12 Regency Direct Vent Flex System Termination Part 946 513 includes all the parts needed to install the P121 P121LC P121RC P131 with a maximum run of 2 feet 1 6 7 8 dia flexible liner 2 ft length 2 4 dia flexible liner 2 ft lengt
4. Louver Side Black Brass set Part Z 181 204 360 940 206 910 172 224 360 942 225 948 216 226 910 142 918 179 Description Extension Trim Dec Grill Front Black set Fan Axial 240V Dec Grill Side Black set Regency Logo Plate Thermodisc Manual Not available as a replacement part Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 35 PARTS LIST P121LC LEFT CORNER MAIN ASSEMBLY Part Description Part Description Part Description 1 360 528 Door Assy Front Tempered 138 360 069 Heat Shield Front 204 360 940 Dec Grill Front Black set 360 538 Door Assy Front Ceramic 206 910 172 Fan Axial 240V Optional 141 360 031 ColumnFinishing Trim 224 360 942 Dec Grill Side Black set 146 360 035 Finishing Trim 2 360 529 Door Assy Side Tempered 225 948 216 Regency Logo Plate 360 539 Door Assy Side Ceramic 149 360 122 Magnet Bracket Corner 226 910 142 Thermodisc Optional 150 360 123 Magnet Bracket Front 151 904 258 Magnet 918 179 Manual 9 360 046 Nailing Strip Top Front 10 360 047 Nailing Strip Top Side 158 360 062 Door Cover Assembly Front Not available as a replacement part 11 430 001 Standoff Top 171 360 920 Louver Front Black set 17 360 086 Gasket Relief Door 360 922 Louver Front Black Gold set 24 Relief Door Assembly 360 924 Louver Front Black Steel set 360 926 Louver Front Black Brass set 32 902 2
5. Side 0 0mm Floor 0 CAUTION REQUIREMENTS The top back and sides of the fireplace are defined by standoffs The metal ends of the standoffs may NOT be recessed into combus tible construction Determine the total thickness of the finished floor eg tile carpet slate to allow the finished surface to be flush with the base of the unit Ceiling Height from Floor 72 1828mm Mantel Height from Base of Unit 39 min 991mm Horizontal Flue Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Flue Clearances 1 1 4 32mm WARNING Fire hazard is an extreme risk if these clearances air space to combustible materials are not adhered to It is of greatest importance that this fireplace and flue system be installed only in accordance with these instructions COMBUSTIBLE MANTELS Because of the extreme heat this fireplace emits the mantel clearanc es are critical Combustible mantel clearances from top of unit are shown in Mantel Clearances Diagram to the right 1210 8 6 4 2 0 Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board 12 This drawing is to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using this scale 10 Combustible Caution Ensure the paint that is used on
6. accompanying appliance knob turn to ON position 4 Turn ON the flame switch 1 Turn OFF the flame switch 3 Push in gas control knob slightly and FORYOURSAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes if any if not follow the current CAN1 B149 ANSI Z 223 1 Australia AS5601 2004 New Zealand NZS 5261 WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consulta qualified installer service agency or gas supplier C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air CAUTION Hotwhile in operation Do nott
7. ARE IN THE SAME ROOM AS THE AP PLIANCE 14 The appliance area must be kept clear and free of combustible materials gases and other flammable vapours and liquids Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or 1 2 3 4 5 6 7 8 9 GENERAL SAFETY INFORMATION The appliance shall be installed in accord ance with the manufacturer s installation instructions local gas fitting regulations municipal building codes water supply reg ulations electrical wiring regulations with AS5601 2004 AGA gas installation code NZS 5261 New Zealand See general construction and assembly instructions The appliance and flue should be enclosed This appliance must be connected to the specified flue and termination cap to the outside of the building envelope Never flue to another room or inside a building Make sure that the flue is fitted as per Flueing instructions Inspect the flueing system annually for blockage and any signs of deterioration Flueing terminals shall not be recessed into a wall or siding Any safety glass removed for servicing must be replaced prior to operating the appliance To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace Wear gloves and safety glasses for pro tection while doing required maintenance Be aware of electrical wiring l
8. Galv 982 Snorkel 14 Rise Termination Cap 90 black elbow wall thimble cover horiz 902B 48 Pipe Length Black 981 Snorkel 36 Rise Termination Cap square termination cap 24 black pipe and 11 911B 11 14 5 8 Adjustable Pipe Length 940 Wall Thimble Support Box 14 5 8 adjustable black pipe Black 941 Cathedral Ceiling Support Box 970 Basic Horiz Termination Kit includes 917B 17 24 Adjustable Length Black 3951 Brass Trim for Wall Thimble Ceiling Sup 90 black elbow wall thimble cover 945 45 Elbow Galv 963 Firestop Spacer horiz square termination cap 945B 45 Elbow Black 943 Flashing 0 12 6 12 978 Vert Termination Kit includes 0 12 945G 45 Elbow Swivel Galv 943S Flashing 7 12 12 12 6 12 pitch adjustable flashing storm 945BG 45 Elbow Swivel Black 953 Storm Collar collar low profile term cap 990 90 Elbow Galv 950 Vinyl Siding Standoff 908B 6 Pipe Length Black 990B 90 Elbow Black 988 Wall Strap 907B 9 Pipe Length Black 990G 90 Elbow Swivel Galv 942 WallThimble 906 12 Pipe Length Galv 990BG 90 Elbow Swivel Black Parts not supplied by Dura Vent 906B 12 Pipe Length Black 991 High Wind Termination Cap Vertical 946 506 Vent Guard Optional 904 24 Pipe Length Galv 980 Vertical Termination Cap 510 994 Dura Vent Flue Adaptor 904B 24 Pipe Length Black 984 Horizontal Square Termination Cap 640 530 P Riser Vent Terminal 903 36 Pipe Length Galv 985 Horiz Square Hig
9. 7 2 13m Max 12 3 6m Max 5 1 5m Min With the above options maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90 elbows is required Diagram 5 Horizontal Flueing with Three 3 90 Elbows 2 610mm Minimum 3 914mm Minimum 3 914mm Maximum 6 1 86m Maximum 4 1 22m Minimum 9 2 7m Maximum 3 914mm Min 5 1 5m Max 9 2 7m Max 5 1 5m Min 8 2 4m Max 12 3 6m Max With the above options maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90 elbows is required Diagram 4 5 1 5m Minimum 12 3 6m Maximum With the above options maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90 elbows is required Diagram 6 16 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION FLUEING ARRANGEMENTS VERTICAL TERMINATIONS SIMPSON DURA VENT DIRECT VENT GS SYSTEM LPG amp NG e Flue must be supported at offsets e Maintain clearances to combustibles as listed on page 9 e Firestops are required at each floor level and whenever passing throu
10. Maximum HORIZONTAL INSTALLATIONS Install the flue system according to the manufacturer s instructions included with the components 1 2 3 4 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the flueing system is at tached If this is the case you may want to adjust the location of the unit Rough in the gas Direct Flue pipe and fittings are designed with special twist lock connections to con nect the flueing system to the appliance flue outlet A twist lock appliance adaptor is an available option that must be used in con junction with the Simpson Dura Vent Direct Vent GS system Puta bead ofsilicone inside the outer section of the adapter and a bead of Mill Pac on the inner collar Slip the adapter over the exist ing inner and outer flue collar and fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier Level the fireplace and fasten it to the framing using nails or screws through the nailing strips Assemble the desired combination of pipe and elbows to the appliance adaptor and twist lock for a solid connection Note a Twist lock procedure Four indentations located on the female ends of pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe inden tations so they match and slide in to the four entry slots on the m
11. P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace MAINTENANCE 2 Remove the Cap and shine a flashlight down the Flue Remove any bird nests or other foreign material 3 Check for evidences of excessive con densation such as water droplets forming in the inner liner and subsequently dripping out the joints Continuous condensation can cause corrosion of caps pipe and fittings It may be caused by having exces sive lateral runs too many elbows and exterior portions of the system being ex posed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and conse quently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagrams under Log Installation Note Improper positioning of logs may create carbon build up and will severely alter the unit s perform ance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Openthe Bottom Louvers orGrills Remove the Top Louver or Grill 2 Remove the Trim Kit Glass Door Log Set Grate and Burner Assemb
12. Room Sealed Gas Fireplace Option 3 WALL THERMOSTAT Can be used with Option 1 or 2 but not both A wall thermostat may be installed if desired connect the wires as per the wiring diagram Use the table below to determine the maximum wire length Note Preferable if the thermostat is in stalled on an interior wall Regency offers an optional programmable ther mostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect millivolt wall thermostat wires to a 240V wire Thermostat Wire Table Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 2 System 14 GA Max Length 16 GA 18 GA 60M J 20 GA 22 GA 2 7 M 27 INSTALLATION WIRING DIAGRAM No electrical power supply is required for the Do not cut the ground terminal off under Caution Ensure that the wires do gas control to operate any circumstances not touch any hot surfaces and are away from sharp edges ON OFF SWITCH Lockwasher 910 138 BLACK Star washer 8 Ground Lug Grounding Lug Detail T for mobile home 2 D 910 610 BLACK o o L ch 910 802 BLACK c SS 9 29 nc Pilot Ground Wire Assembly al 5 CONVECTION AIR DC Spark sss SEELEN SWITCH Box THERMO DISC NORMALLY OPEN
13. authorized Regency dealer only Replacement glass is shipped already installed into the door frame Reinstall as per Glass Door Installation on page 22 REPLACEMENT PARTS Front Door Tempered Part 360 528 Side Door Tempered Part 360 529 Front Door Ceramic Part 360 538 Side Door Ceramic Part 360 539 GOLD PLATED ACCESSORIES The 24 carat gold plated finish requires little maintenance and need only be cleaned with a damp cloth DO NOT use abrasive materials or chemical cleaners as they may harm the finish and void the warranty Clean any finger prints off before turning the unit on REMOVING VALVE 1 Shut off the gas supply 2 Removethe louvers andtrim kit Remove the front door 3 Remove the logs embers 4 Remove the grate by lifting straight up at 1 a e 5 Remove the side brick clip in the top ofthe firebox and then slide the Side Brick Panel out The brick panels are very fragile handle with care 6 Remove the burner by removing the 4 Screws 7 Slide the burner assembly away from the orifice and lift out Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 31 MAINTENANCE 8 Remove the Side Base Brick Panels and finally the Long Base Brick Panels S P 4 Remove Left amp Right Side Base Brick Panels Remove the 2 Long Base Brick Panels 9 Disconnect the inlet gas line 10 Disconnect the 2 TP wires
14. be in stalled on carpeting combustible linoleum tile or other combustible material other than wood flooring the appliance must be in stalled on a metal or wood panel extending the full width and depth of the appliance 4 The Room Sealed Gas Fireplace can be installed as follows Model Position A P121 See Thru B P131 Pier B 131 C P121LC Left Corner D P121RC Right Corner 5 This appliance is Listed for bedroom instal lations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P121 P121LC P121RC P131 Room Sealed Gas Fireplace is approved for al cove installations which meet the clear ances listed on this page 914mm 36 min 914mm 914mm 7 We recommend that you plan your installa tion on paper using exact measurements for clearances and floor protection before actually installing this appliance Have a authorized inspector dealer installer review your plans before installation C P121LC Left Corner Note For Exterior Flue Termination Locations see page 12 D P121RC Right Corner 36 min 914mm 8 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated refer to diagrams on page 8 Clearance to Combustibles from Back 0
15. gt over 14 12 to 16 12 firestop spacer over 16 12 to 18 12 5 e over 18 12 to 20 12 SE pd Diagram 3 over 20 12 to 21 12 20 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION roof pitches the vertical height must be increased A poor draft or down drafting can result from high wind conditions near big trees or adjoining roof lines in these cases increasing the flue height may solve the problem 7 Ensure flue is vertical and secure the base of the flashing to the roof with roofing rails slide storm collar over the pipe section and seal with a mastic 8 Install the vertical termination cap by twist locking it Note Any closets or storage spaces which the flue passes through must be enclosed Offset Chart GS 6 152mm Nominal Diameter ID Offset inches mm Pipe Length L inches mm Height inches Height INSTALLATION PROCEDURES for Regency AstroCap Direct Flue System Flex 1 Locate the unit in the framing rough in the gas Locate the centerline of the termina tion and mark wall accordingly Cut a 10 254mm hole in the wall inside dimen Sion Note A 1 1 2 38mm clearance around the liner must be maintained ex cept that only a 1 25mm clear ance is needed at the termination end We recommend framing a 10 254mm x 10 254mm inside dimensions hole to give struc tural rigidit
16. heat resistant paint Regency uses Stove Bright Paint Metallic Black 6309 Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a author ized service person The appliance and flueing system must be inspected before use and at least annual ly by a authorized field service person to ensure that the flow of combustion and ventilation air is not obstructed Note Never operate the appliance with 6 7 8 out the glass properly secured in place Do not use this appliance if any part has been under water Immediately call a au thorized service technician to inspect the appliance and to replace nay part of the control system and any gas control which has been under water In the event this appliance has been serv iced check that the flue air system has been properly resealed amp reinstalled in accordance with the manufacturer s in structions Verify operation after servicing General Flue Maintenance Conduct an inspection of the flueing system semi annually Recommended areas to inspect as follows 1 Check the Flueing System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These com 918 253a EE d ponents should be replaced immediately 30 Regency P121
17. screws 10 Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve 11 Reinstall the Burner Assembly 13 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak testing 14 Fire up the unit temporarily 15 Check the manifold pressure 16 Reinstall the logs grate and brick panels as needed 17 Reinstall the glass doors 18 Fire up the unit again and check for proper flame appearance 32 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace PARTS LIST P121 SEE THRU MAIN ASSEMBLY Part Description Part Description Part Description 1 360 528 Door Assy Front Tempered 135 360 069 Heat Shield Side 181 Extension Trim See Thru 360 538 Door Assy Front Ceramic Optional 146 360 035 Finishing Trim 204 360 940 Dec Grill Front Black set 150 360 123 Magnet Bracket Front 2 360 529 Door Assy Side Tempered 151 904 258 Magnet 205 948 216 Regency Logo Plate 360 539 Door Assy Side Ceramic 206 910 172 Fan Axial 240V Optional 168 360 068 Door Cover Assembly Side 207 910 142 Thermodisc 9 360 046 Nailing Strip Top Front 171 360 920 Louver Front Black set 918 179 Manual 10 360 047 Nailing Strip Top Side 360 922 Louver Front Black Gold set 11 430 001 Standoff Top 360 924 Louver Front Black Steel set Not available as a replacement part 17 360 086 Gask
18. the label on the unit and if there is a difference the label on the unit is the correct one Regency Gas Fireplace Model O C O Gas Type NG LPG NG LPG Distributed by Western Australia Model Gas Consumption Manifold Pressure Injector Size AGA Approval number to Code AS4553 2000 P121 NG 41m 1 00kPa 1x 31 3 05mm 6379 Electrical 240VAC 50Hz 1 0 amp max Australian Heating Distributors Pty Ltd 31 Clune St Bayswater WA 6053 Eastern Australia Fireplace Products Australia Pty Ltd 21 23 South Link Blvd Dandenong VIC 3175 P121 LPG 38mj 2 65kPa 1x 50 1 78mm P131 NG 41mj 1 00kPa 1x 31 3 05mm P131 LPG 38mj 2 65kPa 1x 50 1 78mm 6379 6379 6379 To be installed by an authorised person in accordance with installation instructions provided with the appliance Serial Number 248 918 181b OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTICLES ON OR AGAINST THIS APPLIANCE STORE CHEMICALS OR FLAMMABLE MATERIALS OR SPRAY AEROSOLS NEAR THIS APPLIANCE OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS APPLIANCE ENCLOSE THIS APPLIANCE 908 602 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION IMPORTANT SAVE THESE INSTRUCTIONS The Regency P121 P121LC P121RC P131 NG or P121 P121LC P121RC P131 LPG Room Sealed Gas Fireplace must be installed in ac cordance AG60
19. the mantel and the facing is Material heat resistant or the paint may discolour 8 12 Mantel If the 3 76mm metal extension trim is removed it must be replaced with a 8 e A c 203mm non combustible material 6 0 3 1 2 c 4 7 Mantel D g gt lt 2 _ LLI 3 inthis are L 0 A 36 Tog of Side View to floor pur Front or Side Opening Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION FRAMING AND FINISHING 1 Forease ofinstallation frame your fireplace after it is positioned and the flue system is installed Remember to install the top standoffs Framing Dimensions See page 11 for assembly Use 2x4 s and frame to local building P121 See Thru P431 Pier P121LC P121RC codes Corner Unit CAUTION Verify your fireplace dimensions framing methods 25 655mm 25 635mm 26 13 13 660mm and finished wall facing details before framing Determine the minus two times minus two times minus two times the finishing the finishing the finishing total thickness of facing material drywall plus ceramic tiles slate etc Allow the finish surface to be flush with the front or side of the unit Total facing thickness can vary from 1 2 B 42 1 2 1080mm 42 1 2 1080mm 42 1 2 1080mm 13mm to 1 1 4 32mm thick material thickness material thickness material thickness 2 When locating your appliance on an ext
20. 02 297 Brick Panel Base Front 360 938 Louver Side Black Brass set 34 902 298 Brick Panel Side e us ES FRS N ge e X 34 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace PARTS LIST 1 2 9 10 11 17 24 32 33 34 Part 360 528 360 538 360 529 360 539 360 046 360 047 430 001 780 013 360 086 902 296 902 297 902 298 P121RC RIGHT CORNER MAIN ASSEMBLY Description Door Assy Front Tempered Door Assy Front Ceramic Optional Door Assy Side Tempered Door Assy Side Ceramic Optional Nailing Strip Top Front Nailing Strip Top Side Standoff Top Standoff Rear Gasket Relief Door Relief Door Assembly Brick Panel Base Side Brick Panel Base Front Brick Panel Side Part 35 902 300 138 360 063 141 360 031 146 360 035 149 360 122 150 360 123 151 904 258 158 360 060 171 360 920 360 922 360 924 360 926 173 360 932 360 934 360 936 360 938 119 Description Brick Panel Front Heat Shield Front Column Finishing Trim Finishing Trim Left Side Magnet Bracket Corner Magnet Bracket Front Magnet Door Cover Assembly Front Louver Front Black set Louver Front Black Gold set Louver Front Black Steel set Louver Front Black Brass set Louver Side Black set Louver Side Black Gold set Louver Side Black Steel set
21. 1 and NZS 5261 and with these instructions Carefully read all the instructions inthis manualfirst Consultthe authority having jurisdiction to determine the need for a permit prior to starting the installation It is the respon sibility of the installer to ensure this fireplace is installed in compliance with manufacturer s instructions and all applicable codes BEFORE YOU START Safe installation and operation of this appliance requires common sense however we are required to make you aware of the following INSTALLATION AND REPAIRSHOULD BEDONE BY A AUTHORIZED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AAUTHORIZED SERVICE PERSON MORE FREQUENT CLEANING MAY BEREQUIRED DUETO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC ITIS IMPER ATIVE THAT CONTROL COMPART MENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLI ANCE BE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATEDOUT OF TRAFFIC AND AWAY FROM FURNI TUREAND DRAPERIES WARNING FAILURE TOINSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE SERIOUS HOUSE FIRE CLOTHINGOROTHERFLAMMABLE MA TERIAL SHOULD NOT BE PLACED ON OR NEARTHE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPECIAL LY THE FIREPLACE GLASS AND SHOULD STAY AWAY TO AVOID BURNS ORCLOTHINGIGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHENTHEY
22. 41 nj Min Input Rating 22mj Supply Pressure min 3 00 kPa Manifold Pressure High 2 65kPa Log Set Ceramic fibre 8 per set Flue System Regency Astrocap Re gency Direct Vent System Flex and Simp son Dura Vent Direct Flue System GAS LINE INSTALLATION The gas line can be brought through either the right the left side orthe bottom ofthe appliance The gas valve is situated on the bottom of the unit The gas line connection may be made of rigid pipe Copper pipe or an approved flex connec tor If you are using rigid pipe ensure that the valve can be removed for servicing Since some municipalities have additional local codes it is always best to consult with your local authorities and AS5601 2004 Australian Installation Code NZS 5261 New Zealand Installation Standard When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks with a soap and water solution or gas leak detector Do not use open flame for leak testing PILOT ADJUSTMENT Pilot Ignitor Thermocouple Thermopile 0000000W0000000 OO OO QOO Burner Periodically check the pilot flames Cor rect flame pattern has three strong blue flames 1 flowing around the thermopile 1 around the thermocoup
23. 96 Brick Panel Base Side 173 360 932 Louver Side Black set 33 902 297 Brick Panel Base Front 360 934 Louver Side Black Gold set 34 902 298 Brick Panel Side 360 936 Louver Side Black Steel set 35 902 300 Brick Panel Front 360 938 Louver Side Black Brass set ae 138 36 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace PARTS LIST 41 42 43 44 56 57 58 66 67 68 69 79 82 83 84 90 91 Not available as a replacement part P121 P121LC P121RC P131 BURNER ASSEMBLY amp LOG SET Part 360 930 904 326 904 327 904 328 904 329 360 574 P 360 378 P 360 090 910 038 W840470 910 190 360 525 360 027 904 690 936 170 910 073 910 074 910 386 910 341 Description Log Set Front Right Log Front Left Log Middle Left Log Middle Right Log Valve Assembly Valve S I T NG Gasket Valve Tray Valve Tray Pilot Assembly NG Pilot Holder Pilot Assembly Gasket Piezo Ignitor and Nut Burner Assembly Grate Assembly Orifice 31 NG Orifice Gasket Spark Generator Battery Holder Spark Generator Switch c w Wire Thermocouple Thermopile St Set Gei es oe i oo fe Z ih mn m mn mm dm Ve Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 37 NOTES 38 Regency P121 P121LC P121RC P131 Zero Clearance Room Sea
24. ATION EXTERIOR FLUE TERMINATION LOCATIONS ie be enable c c K AP LI mi T ec 4 k 1 Je 1 m See note Ill U _ ading indicates prohibite T Flue Terminal areas for flue ee Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601 2004 AGA gas installation code or NZS 5261 New Zealand Minimum Clearance mm a Below eaves balconies or other projections Appliances up to 50 MJ h input 300 Appliances over 50 MJ h input 500 b From the ground or above a balcony 300 C From a return wall or external corner 500 d From a gas meter M 1000 e From an electricity meter or fuse box P 500 f From a drain or soil pipe 150 g Horizontal from any building structure unless appliance is approved for closer installation or obstruction facing a terminal 500 h From any other flue terminal cowl or combustion air intake 500 j Horizontally from an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note l Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note see table below
25. ERSION KIT FROM NG TO LPG MODEL 730 969 FOR P121 P121LC P121RC P131 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A AUTHORIZED GAS FITTER IF INDOUBT DO NOT DO THIS CONVERSION Conversion Kit Contains Qty Part Description 1 910 018 SIT Conversion Kit 50 Turndown LPG 910 037 LPG Injector Pilot Orifice Burner Orifice 50 908 255 Decal Converted to LPG 908 529 5 32 Allen Key 918 032 Instruction Sheet a et et 1 Remove the louvers and trim kit Remove the front door 2 Remove the logs embers 3 Remove the grate by lifting straight up Remove the side brick panels if installed The brick panel is very fragile handle with care 4 Remove the burner assembly by removing the 4 Phillips head screws and then slide the burner assembly away from the orifice and lift out Diagram 1 Remove the left and right screws and then slide the burner assembly away from the orifice and lift out 22 5 Remove pilot inner box by removing the 2 screws 6 Pull off the pilot cap to expose the pilot orifice 7 Unscrew the pilot orifice with the allen key and replace with the LPG pilot orifice in the kit and replace pilot cap 8 Re install pilot inner box using 2 screws 9 Remove burner orifice with a 1 2 spanner and discard Use another spanner to hold on to the elbow behind the orifice Burner Orifice 10 Reinstall new burner orifice LPG stamped 50 and tig
26. Owners amp Installation REGENCY Zero Clearance Room Sealed Gas Fireplac STYLE MODEL See Thru P121 NG P121 LPG LeftCorner P121LC NG P121LC LPG Right Corner P121RC NG P121RC LPG Pier P131 NG P131 LPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING FOR YOUR SAFETY Improper installation adjustment altera What to do if you smell gas tion service or maintenance can cause Donottry to light any appli injury or property damage Refer to this ance manual For assistance or additional infor Do not touch any electrical These gas appliances have been tested in mation consultan authorized installer serv switch do not use any accordance with AS4553 2000 NZS 5262 ice agency or the gas supplier phone in your building and have been certified by the Australian immediately call vour aas Gas Association for installation and operation FORYOURSAFETY suppli y y 9 pplierfrom a neighbour s as described in these Installation and Do notstore oruse gasoline or otherflamma phone Follow the gas sup ble vapours and liquids in the vicinity of this plier s instructions Your unit should be serviced annually or any other appliance If you cannot reach your EENS Installation and service must be performed gas supplier call the fire by an authorized installer service agency or department the gas supplier 918 179a 02 16 06 To the New Owner Co
27. a non abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance Listed below are some examples All are normal operating sounds and should not be considered as defects in your appliance Blower Regency gas appliances use high tech blow ers to push heated air farther into the room It is not unusual for the fan to make a whirring sound when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burner tube s and logs and is made of a different gauge material from the rest of the firebox and body Therefore the varying thick nesses of steel will expand and contract at slightly different rates which can cause tick ing and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is the switch contacts closing and is normal Pilot Flame Whilethe pilotflame is on it can make a very slight whisper sound Gas Control Valve As the g
28. ale ends Dia Note Apply sealant Mill Pac to inner 5 gram 1 Push the pipe sections com pletely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked The female locking lugs will not be visible from the outside on the Black Pipe or fittings They may be located by examining the inside of the female ends Female Jf Locking Mill Pac J Silicone D 7 ji Male T Locking Diagram 1 pipe and high temperature sili cone sealant to outer pipe on eve ry twist lock joint b Horizontal runs of flue must be sup ported every three feet Wall straps are available for this purpose Mark the wall for a 10 x 10 square hole The center ofthe square hole should line up with the centerline of the horizontal pipe Cutand frame the 10 inch square hole in the exterior wall where the flue will be termi nated If the wall being penetrated is con structed of non combustible material i e masonry block or concrete a 7 178mm dia 7 1 2 191mm dia for flex hole is acceptable Note With Dura Vent the minimum height is achieved by installing a 45 elbow di rectly to the flue adaptor center of hole Lg c C om r Oe O o 2 S
29. all the way and hold in until the pilot lights up Continue to hold the control knob in for about 20 seconds after the pilot is lit Release knob 3 Push in gas control knob slightly and turn to ON position 4 Turn ON the flame switch LIT Gas Inlet e S SHUTDOWN PROCEDURE 4 Turn OFF the flame switch 2 Push in gas control knob slightly and turn to OFF position FIRST FIRE DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE The first fire in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time before you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint the burning off of any oils remaining from manufac turing Smoke detectors in the house may go off atthis time Open a few windows to ventilate the room for a couple of hours Note When the glass is cold and the appliance is lit it may cause con densation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up During the first few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use
30. and the 2 TH wires from the valve 11 Remove the 16 Phillips head screws secur ing the valve tray OOO OR Oke T O 5 eomemene exe ee t Exe E h EL 13 Undo the pilot tube from the valve with 7 16 spanner 14 Undo the quick drop out thermocouple nut on the valve with a 9mm metric spanner 15 Remove the Piezo igniter wire and push button assembly 16 Undo the gas out flare nut with a 13 16 spanner 17 Undo the gas out flare fitting with an 11 16 spanner 18 Remove the 6 Phillips head screws from the sides of the valve bracket and remove valve Hint If you are using black pipe ensure that there is a union by the valve otherwise removal will be almost impossible INSTALLING VALVE 1 Attach the valve to the valve bracket with the 6 m5x8 metric screws provided 2 Reconnect the gas out flare fitting with an 11 16 spanner 3 Reconnect the gas out flare nut with a 13 16 spanner 4 Install piezo ignitor push button assembly and reconnect wire 5 Reconnectthe quick drop out thermocouple nut with a 9mm spanner 6 Reconnect the pilot tube nut with a 7 16 spanner 7 Scrape off the old gasket from the floor of the firebox and from the valve tray assem bly 8 Install a new gasket and reinstall the valve tray assembly Note Failure to install a new gasket may severely affect the appliance perform ance 9 Reinstall the 16 hold down
31. as control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process AERATION ADJUSTMENT The burner aeration is factory set Adjustment may be needed due to the local gas supply or altitude As a general rule if the flame is too yellow open up the air shutter if it is too blue close the air shutter NG 10mm open LPG 10mm open NOTE This adjustment is only to be made by an authorised person Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 29 OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS MAINTENANCE INSTRUCTIONS p 1 A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbours phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department
32. e gt N Diagram 2 Note 6 a The horizontal run of flue must be level or have a 1 4 inch rise for every 1 foot of run towards the termination Never allow the flue to run downward This could cause high temperatures and may present the possibility of a fire b Thelocation ofthe horizontal flue termi nation on an exterior wall must meet all local and national building codes and must not be blocked or obstructed For External Flue Terminal Locations see diagram on page 12 The arrow on the flue cap should be pointing up Insure that the 1 1 2 clear ances to combustible materials are main tained Diagram 3 on page 16 Install the termination cap The four wood screws provided should be replaced with appropriate fasteners for stucco brick concrete or other types of sidings Note If installing termination on a siding covered wall a vinyl siding stand off or furring strips must be used Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 19 INSTALLATION Siding apply sealant to all four sides bolt Horizontal nus Top to Vinyl Standoff O lt 4 screws Vinyl siding standoff Wall Thimble Diagram 3
33. e cae 1 45 Elbow ure the wall thickness in 1 Flue Adaptor cluding furring strips Ceiling 963 lt gt ue Horizontal 1 WallThimble Part 963 C 1 Length of pipe to suit wall thickness If a Vinyl Siding Standoff is see chart required it must be used 3 Thimble with vinyl siding measure X Wall thickness is measured from the back outside surface of IRSC NM lt Adi Pipe Length aaa standoffs to the inside mounting surface of without siding and add 2 11 14 5 8 termination cap For siding other than vinyl inches 90 Elbow furring strips may be used instead of the EN i Flat Wall Installation ie Wall Thickness Vent Length inches Required inches 5 1 2 6 Va Elbow 8 1 2 9 SK Simpson Duravent Adaptor 11 1 2 12 AD AN Part 510 994 14 1 2 11 14 5 8 Adj Pipe A 23 1 2 17 24 Adj Pipe The Regency AstroCap is certified for installations using FPI venting systems as well as Simpson Dura Vent and Direct Vent GS Regency and Regency AstroCap are the proprietary trade marks of FPI Fireplace Products International Ltd Simpson Dura Vent and Direct Vent GS are registered and or propri Dura Vent etary trademarks of Simpson Dura Vent Co Inc Direct Vent GS SIMPSON DURA VENT FLUEING COMPONENTS LIST All Simpson Dura Vent components are available directly from Regency Part Description Part Description Part Description 971 Horiz Termination Kit includes 902 48 Pipe Length
34. e product Any alteration to the unit which causes sooting or carbonning that results in damage to the exterior facia is not the responsibility of Regency Industries Ltd General It is essential that all submitted claims provide all of the necessary information including purchase date serial type of unit and part or parts requested Eastern Australia FIREPLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK BLVD DANDENONG VIC 3175 NOTE PLEASE RETAIN YOURINVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECTINSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY ASERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 39 Copyright 2006 FPI Fireplace Products International Ltd All rights reserved Printed in Canada
35. erior wall or in a chase apply Cl e e 29 heu is 1 pui a vapour barrier and drywall as per local building codes DO NOT de deeg INSULATE THEFIREPLACE ITSELF material thickness material thickness CAUTION The unit does not have to be completely enclosed in a chase The clearance on top of the unit is 0 to the standoffs Finish material thickness includes drywall ceramic tile slate etc so combustible building materials can be laid directly on top of the standoffs You must maintain clearance from the flue to combustible materials for both rigid and flex see Flue Clear ances page 9 P121 See Thru P121LC Corner Unit Note These units are non load bearing 10 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION FACING amp FINISHING REQUIREMENTS This fireplace is supplied with a 3 metal extension trim above the fireplace The extension trim may be replaced if the framing is faced with a non combustible material placed flush with the front and side face of the unit and extending from the top of the unit ie tile slate etc Md QOO N NN NN N Non Combustible Material XKKKKX 8 XXXXX OO SCH Top of Unit UNIT ASSEMBLY PRIOR TO INSTALLATION The 4 Top Standoffs must be correctly positioned and attached to the top before unit is
36. ested In areas where there is not an approved service agent or the closest approved service agentis situated more than twenty five 25 kilometres from the installation Australian Heating Distrib utors are not obliged to arrange warranty repairs and travel and or additional labour charges will apply DISTRIBUTORS Western Australia AUSTRALIAN HEATING DISTRIBUTORS 31 CLUNE STREET BAYSWATER WA 6053 SERVICE AGENTS HEARTH HOUSE SERVICE 31 CLUNE STREET BAYSWATER WA 6053 Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim It does not cover installation and operational related problems such as over firing downdrafts or spillage caused by environmental con ditions nearby trees buildings hilltops mountains inade quate flueing or ventilation excessive offsets negative air pressures caused by insufficient make up air mechanical systems such as furnaces fans clothes dryers etc The warranty does not extend to any part or parts which show evidence of misuse or abuse neglect accident or lack of maintenance Products made by other manufacturers and used in con junction with the operation of this appliance without author ization from Regency may nullify your warranty on this product Regency Industries Ltd shall in no event be liable for any special indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of th
37. et Relief Door 360 926 Louver Front Black Brass set 24 Relief Door Assembly 32 902 296 Brick Panel Base Front 33 902 297 Brick Panel Base Side 34 902 298 Brick Panel Side 222205 REE N Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 33 PARTS LIST P131 PIER MAIN ASSEMBLY Part Description Part Description Part Description 1 360 528 Door Assy Front Tempered 141 360 031 ColumnFinishing Trim 181 Extension Trim Pier 360 946 Door Assy Front Ceramic Optional 146 360 035 Finishing Trim 204 360 940 Dec Grill Front Black set 206 910 172 Fan Axial 240V 2 360 529 Door Assy Side Tempered 149 360 122 Magnet Bracket Corner 224 360 942 Dec Grill Side Black set 360 948 Door Assy Side Ceramic 150 360 123 Magnet Bracket Front Optional 151 904 258 Magnet 225 948 216 Regency Logo Plate 226 910 142 Thermodisc 9 360 046 Nailing Strip Top Front 171 360 920 Louver Front Black set 10 360 047 Nailing Strip Top Side 360 922 Louver Front Black Gold set 918 179 Manual 11 430 001 Standoff Top 360 924 Louver Front Black Steel set 360 926 Louver Front Black Brass set Not available as a replacement part 17 360 086 Gasket Relief Door 24 Relief Door Assembly 173 360 932 Louver Side Black set 360 934 Louver Side Black Gold set 32 902 296 Brick Panel Base Side 360 936 Louver Side Black Steel set 33 9
38. gh a wall e Must use optional flue adapter when using Simpson Dura Vent pipe Part 510 994 The P121 P121LC P121RC P131 is approved for a maximum 35 ft 10 7m straight vertical with Simpson Dura Vent Direct Vent GS flue systems for LPG and NG as per diagram 7 below Straight Up Vertical Flueing Vertical Flueing with One 1 90 Elbow 1 305mm Minimum 2 610mm Maximum 2 610mm Minimum 4 1 22m Maximum 3 914mm Minimum 6 1 86m Maximum 4 1 22m Minimum 8 2 4m Maximum op With the above options maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90 elbows is required Maximum 35 10 7m Minimum 6 6 2 0m Diagram 7 Diagram 8 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 17 INSTALLATION Vertical Flueing with Two 2 90 Elbows 1 305mm Minimum 4 1 22m Maximum Vertical Flueing with Two 2 90 Elbows 1 305mm Minimum 2 610mm Minimum 3 914mm Minimum 6 1 86m Maximum 9 2 7m Maximum 2 610mm Maximum 2 610mm Minimum 4 1 22m Maximum 3 914mm Minimum 6 1 86m Maximum 4 1 22m Minimum 12 3 6m Maximum 4 1 22m Minimum 5 1 5m Minimum 6 1 86m Minimum 15 4 5m Maximum 17 5 1m Maximum With the above opt
39. h 3 spring spacers 3 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 drill point stainless steel 4 Wall Thimble required in Canada only AstroCap Termination Cap Part amp 946 578 P 6 7 8 173mm Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from Regency may be used for Flex installations 3 Regency Direct Vent System Flex is only approved for horizontal terminations Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 13 INSTALLATION SIMPSON DURA VENT FLUEING Horizontal or Vertical Terminations The Simpson Dura Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations Many items are offered in decorative black as well as galvanized finish We recommend using the galvanized finish for installation with the P121 P121LC P121RC P131 Vertical The minimum components required for a vinyl siding standoff to Tete basic horizontal termination are create a level surface to Storm Collar mount the vent terminal Part 953 N Vinyl Siding 1 Simpson Duravent Adaptor The Terminal must not be Standoff Optional 1 Horizontal Termination Cap recessed into siding Meas e
40. h Wind Termination 946 205 Vinyl Siding Shield for Riser 903B 36 Pipe Length Black Cap Vent Terminal 946 206 AstroCap Standoff 14 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION FLUEING ARRANGEMENTS HORIZONTAL TERMINATIONS SIMPSON DURA VENT DIRECT VENT GS SYSTEM LPG amp NG The diagram below shows examples of horizontal termination arrangements using one two or three 90 elbows two 45 elbows equal one 90 elbow Note 1 A maximum of three 90 elbows are permitted 2 Minimum distance between elbows is 1 ft 305mm Simpson Dura Vent 4 inner diameter Maintain clearances to combustibles as listed on page 9 6 5 8 outer diameter e Horizontal flue must be supported every 3 feet e Firestops are required at each floor level and whenever passing through a wall e Must use optional flue adapter Part 510 994 when using Simpson Dura Vent pipe vent guard should be used whenever the termination is lower than the specified minimum or as per local codes Straight Out Horizontal Flueing Horizontal Flueing with One 1 90 Elbow 305mm Minimum A 914mm Maximum 610mm Minimum 6 1 86m Maximum 914mm Minimum 9 2 7m Maximum 1 22m Minimum 12 3 6m Maximum 5 1 5m Minimum 15 4 5m Maximum 6 1 86m Minimum 17 5 1m Maximum With the above options maximum total pipe length if 37 feet with mi
41. hten 11 Remove and discard the 3 pressure regu lator mounting screws A pressure regu lator tower B and diaphragm C 12 Insure that the rubber gasket D is properly positioned and install the new HI LO pres sure regulator assembly to the valve using the new screws E supplied with the kit Tighten screws securely 13 Reverse steps 4 to 1 14 Attach clear label This unit has been con verted to LPG near or on the serial decal Attach white label This valve has been converted from NG to LPG using SIT con version Kit Code 0 907 202 onto the valve 15 Replace yellow NG label with red LPG label 16 Check for gas leaks 17 Check inlet and outlet pressures 18 Check operation of flame control 19 Check for proper flame appearance and glow on logs Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION P121 P121LC P121RC P131 NG System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 31 Pilot Orifice NG Max Input Rating 42 mi Min Input Rating 22mj Supply Pressure 1 13 Manifold Pressure High 1 00 kPa Log Set Ceramic fibre 8 per set Flue System Regency Astrocap Re gency Direct Vent System Flex and Simp son Dura Vent Direct Flue System P121 P121LC P121RC P131 LPG System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 50 Pilot Orifice LPG Max Input Rating
42. into the rear of each log The image below shows all of the logs in place 3 Place Log 327 on the front left side of the burner Position the right end of the log in between the two tabs and the left end of the log into the grate post 328 326 329 327 Tab on Burner 327 329 326 328 Grate Post 24 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION Repeat step 3 on the opposite side of the burner Repeat step 5 on the opposite side of the burner 4 Embers should be placed in front of Log 326 Log 327 and also down the middle between the logs as shown in the image below 6 Place Log 328 on the middle right side of the burner Ensure that the log fits over the 2nd grate post from the right M ab gend LED E nd E wl ul Caution Do cover burner ports Grate Post 5 Place Log 329 on the middle left side of the burner Rest the bottom PER of the Log onto the second grate post from the left Ensure that the log fits into a pin that is on Log 326 Grate Post Place Log 329 onto pin Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 25 INSTALLATION GLASS DOOR REMOVAL 1 Remove the 8 screws that secure the glass door 2 Pull the door slightly out on an angle and then lift up and pull completely out 3 P131 amp P121LC P121RC Corner Model Remove the 6 sc
43. ions maximum total 8 2 4m Maximum pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90 elbows is required With the above options maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal Please note minimum 1 foot between 90 elbows is required Diagram 9 2 610mm Min 1 305mm 2 610mm Max 3 914mm Min 4 1 22m Max 5 1 5m Max 4 1 22mm Min 6 1 86m Max 8 2 4m Max 5 1 5m Min 18 2 4m Max 12 3 6m Max With the above options maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90 elbows is required Diagram 11 18 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION V1 Vertical Flueing with Three 3 90 Elbows 2 610mm Minimum 3 914mm Maximum 3 914mm Minimum 6 1 86m Maximum 4 1 22m Minimum 9 2 7m Maximum Diagram 12 5 1 5m Minimum With the above options maximum total pipe length if 37 feet with minimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90 elbows is required 12 3 6m
44. ished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten S I T VALVE DESCRIPTION 1 Gas cock knob 2 Manual high low adjustment 3 Pilot Adjustment 4 Thermocouple Connection option 5 Outlet Pressure Tap 6 Inlet Pressure Tap 7 PilotOutlet 8 Main Gas Outlet 9 Alternative TC Connection Point db EN d Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 23 INSTALLATION LOG INSTALLATION 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position Read the instructions below carefully and refer to the dia replaced Broken logs can interfere with the pilot operation notches on the far right side of the log fit into the grate posts Push back side of the left end of the log up against the tab on the burner Log Kit 360 930 contains the following pieces a 326 Front Right Log 902 326 b 327 Front Left Log 902 327 328 Middle Right Log 902 328 d 329 Middle Left Log 902 329 e Embers 902 154 Please note that there are 2 of each log This log set is mirrored front and back Push back side of the left end of the log up against the tab on the burner Repeat step 2 on the opposite side of the burner The 3 digit numbers ie 327 are molded
45. l 27 Wiring Diagram sssssem RR 28 TABLE OF CONTENTS Operating Instructions Operating Instructions eege 29 Lighting Procedure 29 Shutdown Procedure 29 IRS CP WS DET 29 Normal Operating Sounds of Gas Appliances 29 Aeration Adjustment 29 Lighting Plate Instructions AAA 30 Maintenance Maintenance Instructions 30 General Flue Maintenance 30 Log RENI TOT 31 Thermopile Thermocouple 31 Glass OSSKGL 31 D es ect eee 31 Gold Plated Accessories 31 Removing A ae oue 31 Installing 32 Parts List Replacement Spare Parts 33 Warranty EE 39 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace SAFETY LABEL This is a copy of the label that accompanies each REGENCY P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace We have printed a copy of the contents here for your review The safety label is located on the front inside base of the unit visible when the bottom louver is open NOTE Regency units are constantly being improved Check
46. le and 1 flowing across the burner it does not have to be touching the burner Note If you have an incorrect flame pat tern contact your Regency dealer for further instructions Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple Pilot Ignitor Thermocoup Thermopile OOOO0O0000000cO 000 OO OO QOO OO Burner GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing ofthe gas supply piping system at test pressures equal to or less than 3 45 kPa Disconnect piping from valve at pressures over 3 45 kPa The manifold pressure is controlled by a regu lator built into the gas control and should be checked at the pressure test point Note To properly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When fin
47. led Gas Fireplace WARRANTY Regency Fireplace Products are designed with relia bility and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door Regency Indus tries Ltd is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Prod uct The Warranty Lifetime Covered underthe agreementarethe following components Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating againstdefective manufacture The above will be covered for parts and labour for the first five years and parts only thereafter Electrical components such as fans switches wiring thermodiscs remote control thermopiles thermocouples and gas valves are covered for one year from the date of purchase Conditions All installations must be performed by an authorised gas fitter and installed according to all applicable local and national codes Also all service work must be carried out by an authorised gas service person Itis the responsibility of the installer to ensure that the appliance is firing as per rating plate Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regenoy s option through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requ
48. ly see page 26 3 Disconnect thermocouple by loosening nut from the valve with a 9mm spanner Dis connect thermopile by loosening 2 screws marked TP on the valve 4 Remove 2 screws from the pilot assembly and pull up far enough to be able to loosen the thermocouple orthermopile with a 7 16 spanner NOTE the pilot line is very fragile use caution when pulling it up 5 Dropthe thermocouple or thermopile down through the extrusion and pull it out of the unit 6 Reinstall the new ones in reverse order GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket Part 936 155 DOOR GLASS Your Regency fireplace is supplied with high temperature 5bmm Tempered glass amp 5mm Ce ramic glass If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers Do not use abrasive materials CAUTION amp WARNINGS Do not clean when the glass is hot Theuse of substitute glass will void all product warranties Care must be taken to avoid breakage of the glass Do not strike or abuse the glass Donotoperatethis fireplace without the glass front or with a cracked or broken glass front Wear gloves when removing damaged or broken glass Replacement of the glass panels should be done by a licensed or authorized service per son GLASS REPLACEMENT In the event that you break your glass by impact purchase your replacement from an
49. m 4 2 Set the gas appliance in ma to ensure that the termination is ne not recessed into the siding Sumo cum Ge 7 Before connecting the horizontal run of flue Nees DEE pipe to the flue termination slide the Wall amd the Thimble Part 942 over the flue pipe where the flue will pene Diagram 1 trate the ceiling Drilla small hole at his point Di 4 Th Hall of the fasbnat 8 Side me eppiace and fue assembly fo drop a plumb bob from te rooftothe aera ade fc ooheg mate anc tot Ree pas ipa nol previoUS y dried tne cening nailed down until the chimney is installed pipe into the flue cap assembly It is impor mark the spot where the flue will penetrate This aone DA ee s tant that the flue pipe extends into the flue the roof Determine if ceiling joists roof IS allows 5 aajusiments cap sufficient distance so as to result in a rafters or other ramina will minimum pipe overlap of 1 1 4 inches Se obstruct the flueing 6 Continue to assemble pipe lengths us a inu T i re You may wish Note If an offset is necessary in the attic cad tek d aed to relocate the to avoid obstructions it is impor metal strips extending from the flue cap appliance or to plumber s db assembly into the outer wall of the flue pipe offset as tape tant to support the flue pipe every Use the two shee
50. ngratulations You are the owner of a state of the art Gas Fireplace by REGENCY The P121 P121LC P121RC P131isahandcrafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P121 P121L C P121RC P131 has been approved by the Australian Gas Association for both safety and efficiency As italso bears ourown mark it promises to provide you with economy comfortand security for many trouble free yearstofollow Please take amomentnowto acquaint yourself with these instructions and the many features of your Regency Fireplace IMPORTANT Ifthe unitis to be installed into a bathroom optional Neo ceramic glass Part 360 946 Front or Part 360 948 Side mustbe purchased and installed in place of the tempered glass supplied with theunit 2 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace Safety Label Safety Label ngs 4 Installation Important Message lt Before VOST 5 General Safety Information 5 Installation Checklist B erzielen EE 6 Locating Your Fireplace 8 Eeer 9 Combustible Mantel Clearances 9 Framing and ISA T 10 Facing and Finishing Requirements 11 Unit A
51. nimum of 6 feet total vertical and maximum 17 feettotal horizontal Please note minimum 1 foot between 90 elbows is required Diagram 1 center of hole re TUE die Min height Z flex amp DuraVent 42 3 16 1072mm lt Diagram 2 Please note the minimum centerline for basic install shown above Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 15 INSTALLATION Horizontal Flueing with Two 2 90 Elbows Option 1 305mm Minimum 2 610mm Maximum 2 610mm Minimum 5 1 5m Maximum 3 914mm Minimum 8 2 4m Maximum 4 1 22m Minimum 11 3 35m Maximum 5 1 5m Minimum 14 4 27m Maximum 6 1 86m Minimum 15 4 5m Maximum With the above options maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 15 feet total horizontal Please note minimum 1 foot between 90 elbows is required Diagram 3 Horizontal Flueing with Two 2 90 Elbows Option A B V 1 305mm Min 2 610mm Min H 1 305mm Max 3 0 91m Max H1 3 914mm Max 6 1 86m Max 2 610mm Min 1 305mm Max Horizontal Flueing with Three 3 90 Elbows H H1 H2 3 914mm Max 3 914mm Min 3 914mm Max 6 1 86m Max 4 1 22mm Min 5 1 5m Max 9 2 7m Max
52. ocations in walls and ceilings when cutting holes for termination 10 Under no circumstances should this appli ance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 11 Installation and any repairsto this appliance should be done by a authorized service person A authorized service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 12 Do not slam shut or strike the glass door 13 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance other reproductive harm INSTALLATION CHECKLIST Note These units are non load bearing 1 Locate appliance a Room location page 8 b Clearances to Combustibles page 9 c Mantle Clearances page 9 d Framing amp Finishing Requirements page 10 e Flueing Requirements pages 11 19 2 Assemble Top Standoffs page NOTE page 11 mustbe done before installing unit into fireplace 3 Install flue pages 19 21 4 Make gas connections Testthe pilot Must be as per diagram Page 22 5 Install log set where indicated on page 24 25 6 Glass Door Removal page 26 Louvers or Grills page 26 and Finishing Trim page 26 7 Install optional Wall Switch Remote Con trol or Wall Thermostat page 27 8 Final check Before leaving this unit with
53. of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very im portant Run wires from the fireplace to that location Use the Thermostat Wire Ta ble 2 Connect the two wires to the gas valve See diagram below To thermopile Option 2 WALL SWITCH Can be used with Option 1 or 3 but not both 1 Run the supplied 4 5m of wire through the back gas inlet opening Be careful not to damage wire Note We recommend a maximum of 4 5m of wire but if you wish to go with a longer run use the Thermo stat Wire Table 2 Connectthe wire to the supplied wall switch and install into the receptacle box CAUTION Do not connect millivolt wall switch wire to a 240V wire SES 99 To wall switch al remote control gt dei or thermostat EXIT 4 Gi 4 CAUTION Do not connect millivolt remote control wires to a 240V wire 3 Install 3AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to remote mode The remote control is now ready for operation Regency P121 P121LC P121RC P131 Zero Clearance
54. ouch Severe Burns may result Due to high surface temperatures keep children clothing and furniture gasoline and other liquids having fammable vapors away Keep burner and control compartment clean See installation and operating instructions LIGHTINGINSTRUCTIONS STOP Read the safety information above on this label 1 Push in gas control knob slightly and turn to PILOT position 2 Push in control knob all the way and hold in until the pilot lights up Continue to hold the control knob in for about 20 seconds after the pilot is lit Release Gas Inlet C TO TURN OFF GAS APPLIANCE You may shut off the pilot during prolonged non use periods to conserve fuel 2 Push in gas control knob slightly and turn to OFF position DO NOT REMOVE THIS INSTRUCTION PLATE 1 2 3 4 5 Always turn off the gas valve before cleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacu uming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily damaged Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy The heater is finished in a heat resistant paint and should only be refinished with
55. rews that secure the glass door and repeat step 2 FINISHING TRIM 1 Slidethe Side Finishing Trim up into the slot in the top flange of the fireplace Push tight against the magnet at the base of the unit Slide Trim into Slot Push trim tight against magnet 2 Slide the Corner Finishing Trim up into the slot in the top flange of the fireplace Push tight against the magnet at the base of the unit Slide Trim into Slot Push trim tight against magnet LOUVERS amp GRILLS 1 Attach the screws provided to the top left and right corners NOTE Do not tighten the screw entirely ensure that some room is left to be able to hang the grill or louver over the screw 2 Hang the Top Louver or Grill onto the 2 screws in the top fireplace opening 3 Attach the Bottom Louver or Grill to the hinges on the bottom flange ofthe fireplace P121 amp P131 Corner Models 4 Attach the screws provided to the top and bottom left and right corners similar to step 1 5 Hangthe top and bottom louver or grill onto the screws in the top and bottom left and right sides of the fireplace opening The Top and Bottom Side Louver or Grill is installed the same way 26 Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION Option 1 REMOTE CONTROL Can be used with Option 2 or 3 but not both Use the Regency Remote Control Kit approved for this unit Use
56. s Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION P121LC Left Corner Unit 44 112 1117mm 4 5 12 1 2 304mm 21 1 8 533mm 42 1066mm 36 914mm 11 1 2 279mm 26 13 16 660mm 41 1 2 1041mm 13 5 16 330mm BACK FRONT Gas Line emp Electrical Inlet Inlet 5 1 16 127mm 6 7 8 152mm EM E E 5 5 3 ei Gas BASE Base Note These units are Line Inlet Mounting Holes non load bearing P121RC Right Corner Unit 44 1 2 1117mm 21 1 8 533mm 12 1 2 304mm Ka E L e CH E d N 13 5 16 330mm 11 1 2 279mm 41 1 2 1041mm 26 13 16 660mm Electrical Gas Line Inlet SIDE Inlet FRONT BACK 6 7 8 152mm 5 1 16 127mm 1 e o e Base BASE Gas Line Inlet Mounting Holes Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your stove ensure that the clearances are met as outlined on page 9 36 min 3 min 76mm 914mm Glass A P121 See Thru 2 Provide adequate clearances for servic ing 3 The appliance must be installed on a flat solid continuous surface e g wood met al concrete This may be the floor or raised up on a platform to enhance its visual impact If the appliance is going to
57. slipped into position Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoff and bend into the correct shape Bend up at the bend lines until the screw holes in the standoff and the pre punched screw holes on the fireplace top line up 3 Attach the standoff securely to the top with 4 screws per standoff on opposite cor ners Top Standoff 1 after bending Combustible Material 1 Top Standoff flat shipping position Ne NN Ka Extension Trim __ FLUEING INTRODUCTION The P121 P121LC P121RC P131 uses the balanced flue technology Co Axial system The inner liner flue products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be con nected to any other appliance The gas appliance and flue system must be flueed directly to the outside ofthe building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Each direct flue gas appliance must use it s own separate flue system Common flue sys tems are prohibited Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 11 INSTALL
58. ssembly Prior to Installation Top Standoff Assembly 11 Flueing Introduction 11 Exterior Flue Termination Locations 12 Flueing Direct Vent System Flex 13 Flueing Simpson Dura Vent Direct Vent GS 14 Flueing Simpson Dura Vent Components List 14 Flueing Arrangements Horizontal Terminations 15 Vertical Terminations 17 Flueing Dura Vent Horizontal Installations 19 Flueing Dura Vent Vertical Termination 20 Flueing Installation Procedures for Direct Vent System Flex 21 OMY COMO PES EE 22 PARTIM 23 Gas Line Installation 23 Pilot Adjustment 23 Gas Pipe Pressure 29 S I T Valve Description 23 Log Set Installation EE 24 Glass DoorRemoval 26 FASANO LINT 26 Louvers and Grills 26 Remote Control optional 27 Remote Wall Switch optional SE Wall Thermostat optiona
59. t metal screws provided shown in Dia Connected 3 feet to avoid excessive stress to connectthe strips to the pipe section See gram 2 to avoid to wall strap o FAM tees Diagram 4 i cutting load wall 45 for this purpose Diagram 2 bearing mem 9 Install wall thimble in the center of the 10 bars strap Elbows ee eer eT e square and attach with wood screws Di Ge PIPE Is ADONE MIE FOUR agram 5 line due to its higher corrosion resistance Continue to add pipe sections through the SC Female Ge flashing until the height of the flue cap meets lt f Locking the minimum height requirements specified in 1 1 4 KEE Diagram 2 Di cod N hat f 32mm lagram 5 or local codes Note that for steep fold strap here Note Apply sealant Mill Pac to inner sheet metal pipe and high temperature sili Screw E cone sealant to outer pipe on eve H ry twist lock joint Diagram 5 3 A Firestop spacer must be installed in the nU wall floor or ceiling of every level To install the Roof Pitch inimum Vent Height thimble Firestop spacer in a flat ceiling or wall cut Feet Meters cover a 10 inch square hole Frame the hole as fat to 7 12 Feet ees strap shown in Diagram 3 and install the firestop ALTO Diagram 4 over 7 12 to 8 12 10 254 over 8 12 to 9 12 over 9 12 to 10 12 framing L over 10 12 to 11 12 el IE over 11 12 to 12 12 lt gt over 12 12 to 14 12
60. the customer the installer mustensure thatthe appliance is firing correctly and operation fully explained to cus tomer This includes 1 Clocking the appliance to ensure the cor rect firing rate rate noted on label 40 000 Btu h NG and 39 000 Btu h LPG after burning appliance for 15 minutes 2 If required adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 20 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage is not the responsi bility of the manufacturer Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace INSTALLATION SPECIFICATIONS P121 See Thru 46 1 4 1175mm 12 1 2 318mm 21 1 8 537mm 4 3 4 120mm 42 1067mm 36 914mm 43 1 2 1105mm 25 635mm 11 3 8 289mm 11 1 2 292mm Electrical BACK Gas Line FRONT SIDE Inlet Inlet 6 7 8 175mm Note These units are non load bearing 4 3 8 111mm 4 3 8 114mm gt Base BASE Gas Mounting Holes Line Inlet P131 Pier 44 1 2 1130mm 21 1 8 536mm 42 1066mm 36 914mm 4 2 50mm 41 1 2 1054mm 25 635mm 11 1 2 292mm SIDE 11 3 8 292mm Electrical BACK Gas Line FRONT Inlet Inlet 5 1 8 130mm E E E o o Base BASE Gas Line Inlet Mounting Hole
61. ure the termination cap faces up there are markings on the cap that show which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre 4 100mm liner and outer 6 7 8 175mm liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 45 7 Apply Mill Pac over the fireplace inner collar and slip the 4 100mm liner down over it and attach with 3 supplied screws 8 Do the same with the 6 7 8 1 75mm liner 9 Apply a bead of silicone between the thim ble and termination and around the outer edge of the terminal at the wall in order to keep the water out IMPORTANT Do not locate termination hood where excessive snow or ice build up may occur Be sure to check flue termi nation area after snow falls and clear to prevent accidental blockage of flueing system When using snow blowers make sure snow is not directed towards flue termination area 2 x4 or2 x6 4 dia flue pipe with spring spacer ap Screws QUI Wall Thimble 2 pieces 10 Outer Diameter MANI T JE air intake connection Regency P121 P121LC P121RC P131 Zero Clearance Room Sealed Gas Fireplace 21 INSTALLATION CONV
62. y for mounting the ter mination Note If installing termination on a siding covered wall furring strips must Note To make the installation more aesthetically pleas ing we recom mend framing out a square to mount the terminal to be used to ensure that the termi nation is not recessed into the siding 2 Level the fireplace and fasten it to the framing using nails or screws through the nailing strips 3 Assemble the flue assembly by applying Mill Pac to the 4 100mm inner collar of the termination and slipping the 4 100mm liner over it at least 1 3 8 35mm Fasten with the 3 screws drilling pilot holes will make this easier Apply Mill Pac or high temper ature silicone to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the flue terminal at least 1 3 8 35mm and fas ten with the 3 screws NOTE Horizontal sections must be sup ported at intervals not exceeding 3 feet 0 9 meter Flame picture and performance will be affected by sags in the liner 4 Separate the 2 halves ofthe wallthimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom Fasten the other thimble halfto the inside wall The thimble halves slip inside each other and can be adjusted for 2x4or2 x 6 walls The liners must slip over the collars a minimum of 1 3 8 5 Slip the assembled liner and termination assembly through the thimble making s