Regency Wraps U38-LP User's Manual
Contents
1. FIREPLACE PRODUCTS REGENCY www regency fire com ULTIMATE U38 Freestanding Gas Stove eS F Installation Manual MODELS U38 NG Natural Gas U38 LP Propane WARNING FOR YOUR SAFETY Ifthe information in these instructions are not followed exactly What to do if you smell gas a fire or explosion may result causing property damage Do not try to light any appliance personal injury or loss of life e Do not touch any electrical switch do not use any phone in your FOR YOUR SAFETY building Do not store or use gasoline or other flammable vapors and Immediately call your gas supplier liquids in the vicinity of this or any other appliance from a neighbour s phone Follow the gas supplier s instructions O If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Tested by WWTERTE Installer Please complete the details on the back cover van and leave this manual with the homeowner A i am Pa Homeowner Please keep these instructions for future reference ar a wot 918 026 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 10 06 03 To the New Owner Congratulations You are the owner of a state of the art ULTIMATE Gas Stove by FIREPLACE PRODUCTS INTERNATIONALLTD The Regency Gas Series of hand crafted appliances has been designed to provide yo
2. local codes if any If not follow ANSI Z223 1 CAN codes locaux s il n existe aucun code local se conformer a la norme CGA B149 Electrical Supply 115 V 1 13 A 60 Hz ANSI Z223 1 CAN 1 B149 en vigueur Alimentation lectrique Ne doit Not for use with solid fuel pas tre utilis avec un combustible solide EI Fireplace Products International Ltd Delta BC Canada Made in CANADA FABRIQUE AU CANADA 918 029 rev 900 For the State of Massachusetts installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts For the State of Massachusetts flexible connectors shall not exceed 36 inches in length For the State of Massachusetts the appliances individual manual shut off must be a t handle type valve 4 Regency U38 ULTIMATE Freestanding Gas Stove INSTALLATION BEFORE YOU START Safe installation and operation of this appliance requires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALI FIED SERVICE PERSON THE AP PLIANCE SHOULD BE INSPECT ED BEFORE USE AND AT LEAST ANNUALLY BY APROFESSIONAL SERVICE PERSON MORE FRE QUENT CLEANING MAY BE RE QUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERA TIVE THAT CONTROL COMPART MENTS BURNERS AND CIRCU LATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CL
3. The bottom right edge of Log G 02 48 must sit snugly against the bracket 12 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any block age of the burner port d IEN 02 44 Regency U38 ULTIMATE Freestanding Gas Heater 11 INSTALLATION FRONT DOOR INSTALLATION packaged separately 1 ss Open the two side panels 2 Slide the door onto the two hinge pins making sure the two pieces are flush to gether See di agram 1 ss Two 3 Close the door The latch plate must be centered around the alignment pin See dia gram 2 Ifthe latch plate interferes with the cor ner of the stove you may want to angle the plate slightly so the door closes easier Diagram 1 4 The latches should already be at the proper setting If they are too hard or too easy to close you may want to adjust them by loosening the latch catch See diagram 3 Adjustable latch Latch plate s4 Alignment pin Diagram 2 5 Remove the blue plastic protective coating from the glass 6 Test the seal around the door by placing a piece of paper between the unit and the door close the door and try to pull the paper out If it slips out easily then the door is not properly sealed Tighten or loosen the latch See diagram 3 Catch P h Diagram 3 Not
4. er Fan access panel f Ay 4 VORTE 7 L E L N 2 he Thermodisc Diagram 2 4 Lift fan off of the 2 pins tip back and pull through firebox opening Disconnect the green ground wire from the left side of the fan as soon as you can reach it Replacing U38 Fan Reverse the above steps 1 4 If necessary install a new gasket before replacing the fan access panel Make sure the fan wires and the ground wire are reattached 18 Regency U38 ULTIMATE Freestanding Gas Stove MAINTENANCE If your valve requires maintenance or replace ment follow these instructions NOTE Always shut off the gas supply before removing the valve 1 Open front pedestal door and unhook chain You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint See diagram below PILOT control knob 2 Undo the six screws holding the control panel in place 3 Disconnect all wires from the back of the panel and then remove panel You should lay the panel on a soft cloth so it doesn t get marked up See diagram below Cloth 4 Remove the two outside frame pieces by removing two screws per side See dia gram below REMOVING VALVE JII J Jel 5 Carefully remove the logs and lava rock 6 Atthis point you should discon
5. mostat pages 12 and 13 12 Final check page 13 Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to cus tomer This includes 1 Clocking the appliance to ensure the cor rect firing rate rate noted on label after burning appliance for 15 minutes 2 If required adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 20 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning or that results in damage is not the responsibility of the manu facturer CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM dis tances Measure the clearance to both the appliance and the chimney connector The farthest distance is correct if the two clearances do not coincide For example if the appliance is set as indicated in one of the figures but the connector is too close move the stove until the correct clearance to the connec tor is obtained This unit can be installed on a solid combustible surface like a wood floor This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate provided with unit is installed This appliance may be installed only with the clearances as shown in the situations pictured Do not combine clearances from one type of installation with another in order to achieve closer c
6. burn Ifthe pilot does not remain lit repeat operation allowing a longer period before releasing PILOT knob 6 Turn PILOT knob counter clockwise to on 7 Use the Burner ON OFF switch to turn on the burner 8 Rotate the HEAT control to adjust the flame height higher or lower SHUTDOWN INSTRUCTIONS 1 Use the Burner ON OFF switch thermostat or remote control to turn off the burner 2 Push in the PILOT knob slightly and turn clockwise to off Do not force 3 Turn off all electric power to the appliance if service is to be performed FIRST FIRE The FIRST FIRE in your stove is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac turing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT Note When the glass is cold and the appliance is lit it may cause con densation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE AUTOMATIC CONVECTION FAN OPERATION The f
7. by a qualified gas service person It is the responsibility of the installer to ensure that the appliance is firing as per rating plate Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency s option through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim It does not cover installation and operational related problems such as over firing downdrafts or spillage caused by environmental conditions nearby trees buildings hilltops mountains inadequate venting or ventilation excessive offsets negative air pressures caused by insufficient make up air mechanical systems such as furnaces fans clothes dryers etc The warranty does not extend to any part or parts which show evidence of misuse or abuse neglect accident or lack of maintenance Products made by other manufacturers and used in conjunction with the operation of this appliance without authorization from Regency may nullify your warranty on this product Regency Industries Ltd shall in no event be liable for any special indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product Any alteration to the unit which causes sooting or carboning that resul
8. for Side Panel Side Panel Door Magnet Door Latch c w Hook Yp 34 Sj OPTIONAL 33 FLUE COLLAR Regency U38 ULTIMATE Freestanding Gas Stove PARTS LIST 60 Not available as a replacement part Part 910 241 910 190 904 586 910 373 910 372 908 646 650 220 910 330 750 524 P 750 526 P 910 378 910 380 904 240 904 690 904 390 904 641 730 528 910 034 910 035 730 935 730 550 260 565 904 565 U38 BURNER amp LOG ASSEMBLY Description Burner ON OFF Switch 3 way Piezo Ignitor amp Nut Knob Fan Control Switch Knob Pilot Valve Extension Flame Adjusting Knob Control Panel Decal Control Panel Plate Fan Speed Control 120 V Valve Assembly Natural Gas Valve Assembly Propane Valve S I T Natural Gas Valve S I T Propane 37 Orifice N G at 30 000 Btu hr 31 Orifice N G at 40 000 Btu hr 52 Orifice Propane at 30 000 Btu hr 50 Orifice Propane at 38 000 Btu hr Rear Log Bracket Assy Pilot Assy S 1 T 3 flame N G Pilot Assy S 1 T 3 flame Propane Log Set Burner Assy NG LP Air Shutter Gear Assembly Female Hex Key 3 16 AF Air Shutter Gear Assembly Male Seca aS a ae a Ss are a a eas PN es Regency U38 ULTIMATE Freestanding Gas Heater 21 PARTS LIST U38 DOOR ASSEMBLIES Part Description 730 924 Gold Mitred Door Complete MITRE DOOR 730 926 Black Mitred Door Complete 112 730 932 Gold Wrap Doo
9. ft we recommend that a minimum flue height of 12 ft is used Flue Mounting Bracket Attach the flue mounting bracket with the enclosed screw as shown in the diagram Screw Flue Mounting Bracket screw hole at rear of stove top Vent Terminations Vent less than 10 ft 3m from wall JE locate rain cap gE not less than NS 2 ft 600mm oO above wall Do Never this do this Minimum vertical distance in ft m from roof up to lowest opening in top G Sh 0 6 ood ITITI T 242 442 642 842 1042 1242 1442 162 1842 Roof pitch Min Vertical Distance O SNORORRUMNMN G oO oO NN NN nnn Installation into Existing Woodstove Flue System 1 Clean existing Chimney system 2 Runanapproved 4 flex liner or B ventinto existing chimney Note See the chimney systems manufacturer for detailed installation instructions Existing Chimney 4 Flex Liner 4 to 6 Adapte DI Regency U38 ULTIMATE Freestanding Gas Heater INSTALLATION GAS CONNECTION The gas line can be rigid pipe or to make installation easier use a listed flexible connec tor if allowed by local codes Copper may also be used if approved by local codes The gas connection at the valve is 3 8 NPT For minimum and maximum supply pressure see the System Data Table System Data U38 with 40 000 BTU U38 NG For 0 to 2000 feet altitude U38 LP For 0 to 4500 feet alttitude Burner Inlet Orific
10. is very impor tant Run wires from the fireplace to that location use Thermostat Wire Table FINAL CHECK Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly This includes Connect the wires as per the wiring dia gram above 1 Clocking the appliance to ensure the cor rect firing rate rate noted on label at 15 minutes CAUTION Do not connect the millivolt remote control wires to the 120V wires 2 If required adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver Install the receiver and its cover in the wall Switch the remote receiver to remote mode The remote control is now ready for operation 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that LEG To wall switch results in damage to the exterior See gt remote control facia is not the responsibility of 5 or thermostat the manufacturer To thermopile WIRING WARNING Electrical Grounding Instructions This appliance is equipped with athree pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly groundedthree prong receptacle Do not cut or
11. 0 4500 ft z Orifice size 37 DMS Dimensions de Il orifice Maximum Input 30 000 Btu h 8 78Kwh Debit calorifique maximum selon F Minimum Input 15 000 Btu h 4 39Kwh D bit calorifique minimum selon 2 FACTORY EQUIPPED FOR PROPANE GAS Model U38 LP EQUIPE AL UISINE POUR GAZ PROPANE j O Minimum supply pressure 12 WC C E 3 00Kpa Pression d alimentation minimum Manifold pressure High 11 WC C E 2 74Kpa Pression tubulure d chappement lev e 2 Manifold pressure Low 2 9 WC C E 0 72Kpa Pression tubulure d echappement basse 7 1 2 190mm Orifice size 50 DMS Dimensions de Il orifice B 6 155mm gt Altitude 0 2 000ft pi 0 610m L altitude E 2 50mm Maximum Input 38 000 BTU h 11 14Kw h D bit calorifique maximum selon Min Ceiling Height Minimum Input 20 000 BTU h 5 86Kw h D bit calorifique minimum selon from top of unit Min Model U38 LP Convertible to 30 000 Btu for Altitude 0 4500 ft i i sts si lt lt i lt i CS Plafond Hauteur en Orifice size 52 DMS Dimensions de lorifice haut de l appareil Maximum Input 30 000 Btu h 8 78Kwh D bit calorifique maximum selon 36 914 mm a Minimum Input 15 000 Btu h 4 39Kwh D bit calorifique minimum selon GAS FIRED VENTED ROOM HEATER POLE R GAZ RADIATEUR VENTILE This appliance must be installed in accordance with Cet appareil doit tre install conformement aux exigences des
12. 1 drop of glue where previously glued and put in place 4 Install side retainers 5 Install door catch plate 6 Install the 24 nuts loosely do not tighten yet 7 Tighten side panels nuts using the following procedure alee Glass _ Front Glass x Glass Extrusion a tighten top amp bottom outside corner nuts 2 b tighten inside nuts 3 tighten top amp bottom inside corners 2 8 Tightenthe 10 nuts on center glass retainer 9 Repeat step 7 for other side panel 10 Replace new gasket by gluing it in place 11 Install door onto stove and check the seal PANEL DOOR 1 Remove the door from the unit and place on a soft surface to prevent scratching 2 Pull out the door gasket 3 Remove the nuts holding the glass retainers in place 4 Remove the glass retainers sides top and bottom and the door catch plate 5 Replace the glass The glass must have gasketing around it 6 Reverse the previous steps replace the retainers and fasten with the nuts but do not overtighten as this can break the glass Note the door catch plate fits on top of the left side retainer 7 Put gasket glue on the retainers but do not put glue on the screws Replace the door gasket the two ends butt tight together on the bottom edge of the door 8 Replace door on the stove and check the seal White Lyotherm Yh Glass N Glass a Center Short Side Sid
13. 2 psig 14 w c The manifold pressure is controlled by a regu lator built into the gas control and should be checked at the pressure test point Note To properly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN 7 and or OUT 6 pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON position 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Screw should be snug but do not over tighten S I T Valve Description 1 Gas cock knob 2 Manual high low adjustment 3 Pilot Adjustment 4 Thermocouple Connection 5 Main Operator 6 Outlet Pressure Tap 7 Inlet Pressure Tap 8 Pilot Outlet 9 Main Gas Outlet 10 Flange Securing Screw Holes 11 Alternative TC Connection Point 12 Thermoelectric Unit 13 Additional Valve Mounting Hole Regency U38 ULTIMATE Freestanding Gas Stove INSTALLATION CONVERSION FROM NATUAL GAS TO PROPANE THIS CONVERSION MUST BE DONE BY A QUALIFIED
14. BLE 10 ROO EEE EE E 7 Pign an SL EE ER 7 Venting tres suncasinisianneutnreaniitscumdatentinennvadioleaninetoundadtentieasnedidean 7 Venting Requirements cccccsscecseeecseeeeeeseeseeees 7 Flue Mounting Bracket rronnnnornnnrrrnnnvnnnnnnvnnnnnnnnnr 7 Vent Terminations rrnnenanonanrnnnenanrnannnnvnnernnnennnennee 7 Installation into Existing Woodstove Flue System 7 Gas CONMCCHONY sissien opinan ae anei EANN 8 System DAA caerme a 8 Gas Pressure Test ccccceseececeeseceeeeeeeeceeeeeeeaeeeeeseeees 8 Conversion from Natural Gas to Propane 00008 9 Conversion to Lower Btu ccccccceeeeeeeseeeceeeeeesaees 10 Log TAS ANA GIT EEE EE 10 Door Installation and Door Latch r ranrrnnnennnrrnnnennnnrn 12 U38 Louver Installation orrrronrernnnrrrnnrerrannernnnennnnre 12 Test for Flue Spillage 2 ccscecccccesseceesceeeeeeeseeeseees 12 Optional Wall Thermostat rrrronrrrrrrrnnnnrrrrrnnnnrrnnnnnn 12 Optional Remote Control Installation rorrrnnrmmnnn 13 FN ENN 13 Wining Diag ar sasshectatonscaatansnneesmnnysncenuescnavanidenanenchautas 13 Regency U38 ULTIMATE Freestanding Gas Heater Page Operating Instructions Operating Instructions wsscieiiicdsenncaiceteadteonecastuacsdenscnantneucs 14 Lighting Instructions cccceececeeeeeeeeeeeeeeeeeeeeesaeeeesaaees 14 Shutdown Instructions sccsccneieneencnnicapemssunteavanctuen
15. EAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LO CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TOINSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WAR RANTY CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA TURES ESPECIALLY THE FIRE PLACE GLASS AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHINGIGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMA BLE MATERIAL SHOULD NOT BE PLACED ONOR NEAR THE APPLI ANCE IMPORTANT SAVE THESE INSTRUCTIONS The ULTIMATE Freestanding Gas Stove must be installed in accordance with these instruc tions Carefully read all the instructions in this manual first Consult the authority having juris diction to determine the need for a permit prior to starting the installation GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or Nation al Gas Codes CAN1 B149 or ANSI 223 1 Installation Codes 2 The appliance when installed must be elec trically grounded in accordance with local codes or in the absence of local codes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 This appliance is Listed for bedroom instal lations when used with a Listed Mi
16. GAS FITTER IF INDOUBT DO NOT DO THIS CONVERSION Conversion Kit 730 969 Contains 7 Unscrew the pilot orifice with the allen key Qty Part 1 h h h aa 1 Shut off the gas supply 2 Open the front door and carefully remove the logs and lava rock 3 Remove burner See diagram below 910 018 910 037 904 641 908 528 908 255 918 032 Note Use a ee type screwdriver if pos sible and replace with the LP pilot orifice in the kit Description SIT Conversion Kit 50 Turndown LP LP Injector Pilot Orifice Burner Orifice 50 Red PROPANE label Label Converted to Propane Instruction Sheet 00 Remove burner orifice with a 1 2 wrench and discard Use a wrench to hold on to the elbow behind the orifice Burner Orifice 9 Reinstall new burner orifice LP stamped 50 and tighten 10 Reverse steps 3 to 2 11 Attach the Conversion label This unit has Pilot assembly is now accessible for been converted to Propane on top of the steps 4 to 9 Serial decal 4 Remove and discard the 3 pressure regu 12 Replace yellow Natural Gas label with red lator mounting screws A pressure reg Propane label ulator tower B and diaphragm C 13 Check for gas leaks Insure that the rubber gasket D is properly positioned and install the new HI LO pres 14 Check inlet and outlet pressures sure regulator assembly to the valve using the new screws E supplied with t
17. N OR NEAR THE APPLI ANCE DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TOINSPECT THE APPLIANCE AND TO REPLACE ANY PART OF CON TROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UN DER WATER 6 Verify proper operation after servicing LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagram under Log Installation Note Improper positioning of logs may create carbon build up and will alter the unit s performance which is not covered under war ranty DOOR AND GLASS GASKET If the door gasket requires replacement use 7 8 diameter oval door gasket Part 650 920 The glass requires 5 8 flat glass gasket See your Regency dealer GOLD PLATED DOORS The 24 carat gold plated finish on the door requires little maintenance and need only be cleaned with a damp cloth DO NOT use abrasive materials or chemical cleaners as they may harm the finish and will void the warranty Clean any fingerprints off before turning the unit on GLASS REPLACEMENT Your Regency stove is supplied with high temperature 5 mm Neoceram ceramic glass that will withst
18. OM HEATER DO NOT REMOVE THIS LABELINE V VZ Tested to CGA 2 17 M91 ANSI Z21 88 1998 r PAS ENLEVER CETTE Sy CSA 2 33 M98 c fem US Certified for Certifiee pour CANADA and USA REGENCY ez Report No 476 1846 00 Oct 2000 Serial No No de serie FACTORY EQUIPPED FOR NATURAL GAS Model U38 NG QUIP L UISINE POUR GAZ NATUREL Minimum Clearance IO Minimum supply pressure 5 WC C E 1 25kPa Pression d alimentation minimum to Combustibles Manifold pressure High 3 8 WC C E 0 94kPa Pression tubulure d chappement lev e Degagement amp Manifold pressure Low 1 1 _WC C E 0 27kPa Pression tubulure d chappement basse minimum des Model U38 NG Factory Equipped for Altitude 0 2000 ft materiaux Orifice size 31 DMS Dimensions de Il orifice combustibles 4 Altitude 0 2000 ft pi 0 610 L altitude Back wall I Maximum Input 40 000 Btu h 11 73Kwh D bit calorifique maximum selon amp minimum input _ 4 21 000 Btu h 6 15Kwh D bit calorifique minimum selon gt 3l amp Model U38 NG Convertible for Altitude 2000 4500 ft Transforme en haute l altitude Gaz Naturel z Orifice size 33 DMS Dimensions de P orifice Z Altitude 2000 4500ft pi 610 1370m L altitude Maximum Input 36 000 Btu h 10 55Kw D bit calorifique maximum selon Minimum Input 19 000 Btu h 5 57Kwh D bit calorifique minimum selon ____ Bakwa Model U38 NG Convertible to 30 000 Btu for Altitude
19. To adjust the aeration use the allen key to turn the turning gear which will adjust the air shutter Open the air shutter for a blue flame or close it for a yellower flame Closed Tall yellow flame Open Short blue flame NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance This is perfectly nor mal due to the fact that there are various gauges and types of steel used within your appliance Listed below are some examples All are nor mal operating sounds and should not be considered as defects in your appliance Blower Regency gas appliances use high tech blowers to push heated air farther into the room It is not unusual for the fan to make a whirring sound when ON This sound will increase or decrease in volume depending on the speed setting of your fan speed control Burner Tray The burner tray is positioned directly under the burner tube s and logs and is made of a different gauge material from the rest of the firebox and body Therefore the varying thick nesses of steel will expand and contract at slightly different rates which can cause tick ing and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is th
20. aaneasiienes 14 EEA EE 14 Convection Fan Operation ccccccceessseeeeeeseeeeeeeeaes 14 Flame Height Adjustment rrrnnnnrnnnnnrrvrnnnnrnnnnrennnnnre 14 Copy of Lighting Plate Instructions rrrrrnnrrerrnnnnnnn 15 Pilot Adjustment rrrrrnnnrrnnnnrrnnnnnnevnnnnanvnnnnennnnnrennnnsre 16 Aeration Adjustment rrrrnnennnnrrnnnnvrvannnvnnnrnvnnnnnnnnennnn 16 Normal Operating Sounds of Gas Appliances 16 Maintenance Maintenance Instructions ccccceeecseeeseeeeeeeeeeeeees 17 Log Replacement ua tcsavachinaeceucsnrteleascdiatbedvnieeusean 17 Gold Plated DOOS Lunnevenemdaaenieieantens 17 Door and Glass Gasket cccccssscceseeseeeeeeseeeeeeeees 17 Glass FE ENE ne 17 Mitred DOOF sceccccste deeccncadsnousscnctieacteneneeshieceswpetearieases 17 aP anel DOO reo E E 18 Fan Maintenance ed 18 Replacing Fan EEE 18 Removing VE 19 FE A A E E T E EET 20 Warranty MGT ANY E E notteecaesecesecec eee 23 3 SAFETY LABEL This is a copy of the label that accompanies NOTE Regency units are constantly being each ULTIMATE Freestanding Gas Stove We improved Check the label on the unit and ifthere have printed a copy of the contents here for isadifference the label on the unit is the correct your review The safety label is located onthe one inside of the drop down pedestal door Copy of the Safety Label for the U38 Freestanding Gas Stove aa Hersey Listed GAS FIRED VENTED RO
21. an operates automatically turn the knob on the pedestal control panel to adjust to the desired speed The fan will turn on as the stove comes up to operating temperature After the unit has been turned off and cools to below a useful heat output range the fan will shut off automatically Fan switch ADJUSTING FLAME HEIGHT Your heater has an adjustable flame to tailor the look and heat output to your specific needs It is adjusted by turning the flame adjustment dial on the gas control valve 6 gt FAN Sie DD EG 2 pr 2 3 E V Turn clockwise to adjust the flame higher counter clockwise for a lower flame SN fr HEAT 14 Regency U38 ULTIMATE Freestanding Gas Stove OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes if any if not follow the current CAN1 B149 ANSI Z 223 1 Australia AG601 New Zealand NZS 5261 WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified install
22. and the highest heat that your unit will produce In the event that you break your glass purchase your replacement from an authorized Regency dealer only and follow the step by step instructions for replacement Never operate your unit with broken glass WARNING Do not operate appliance with the glass front removed cracked or bro ken Replacement of the glass should be done by a licensed or qualified service person MITRED DOOR Removing Glass Note Wearing gloves will protect your hands while handling glass 1 Remove the door from the unit and place on a soft surface to prevent scratching 2 Pull out the door gasket 3 Remove the 24 nuts holding the glass re tainers in place Do not remove the nuts underneath the retainers White 5 o S Strip cnet H Glass N Clase Extrusion i Center Retainer Door Catch Plate Side Retainer Retainer 4 Remove the door catch plate 5 Remove glass retainers on sides first 3 each side then remove two center retain ers Note Center glass retainers are glued to center glass 6 Remove glass from extrusions When re moving center glass leave white insulation in place Regency U38 ULTIMATE Freestanding Gas Heater 17 MAINTENANCE Installing Glass 1 Install both center and side glass onto extrusions as per diagram 2 Place glass assembly into door frame 3 Install retainers by placing
23. e The door latch may require ad justment as the door gasket mate rial compresses after a few fires and after glass replacement Turn the latch catch inward or outward to loosen or tighten LOUVER INSTALLATION 1 Attach the top amp bottom louvers to the side stove panel using 2 screws per side Louver Assembly Pes Louver Bracket TEST FOR FLUE SPILLAGE A spillage test must be made before the installed unit is left with the customer Follow the procedure below 1 Start all exhaust fans in the home and any other gas appliances Then close all doors and windows 2 Light the unit and set controls to maximum 3 After five minutes test that there is a pull on the flue by placing a smoke match cigarette or similar device which gives off smoke on the edge of the draft hood See diagrams Draft Hood Smoke Match The smoke should be drawn into the draft hood If the smoke is not drawn into the draft hood turn the unit off and check for the cause of lack of draft Down Draft M spillage Draft Hood Flue Gas Smoke Match Note If the flue is blocked or has a strong reverse flow the thermally actuated safe ty switch mounted in the draft hood will automatically shut off the gas supply within about 10 minutes If the heater turns off because of this during the spill age test check for the cause of the lack of draft Blocked Flue Draft Hood F
24. e switch contacts closing and is normal Pilot Flame While the pilot flame is on itcan make avery slight whisper sound O 5 O00 Air Shutter Front oF Burner Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal Top View of pilot flame operation of a gas regulator or valve gt v Unit Body Firebox Q Different types and thicknesses of steel will hi expand and contract at different rates resulting Turning 3 16 in some cracking and ticking sounds will be GE ME heard throughout the cycling process Clockwise to open counter clockwise to close Caution Carbon will be produced if the air shutter is closed too much Note Any damage due to carboning re sulting from improperly setting the aeration controls is NOT covered under warranty Note Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service 16 Regency U38 ULTIMATE Freestanding Gas Stove MAINTENANCE MAINTENANCE INSTRUCTIONS 1 Always shut the valve off before cleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean brush as the logs are fragile and easily damaged 2 Clean glass never when unit is hot ap pliance louvers and door with a damp cloth Never use an abrasive cleaner The gold l
25. e Retainer Retainer Pa Retainer Door L A Catch Door Gasket gasket Plate T ends butt tight together on bottom edge of door FAN MAINTENANCE If your fan requires maintenance or replace ment access to the fan is through the access panel on the rear wall of the firebox Note The unit MUST NOT be operated without the fan access panel se curely in place and correctly sealed IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan mo tors on a regular basis by vacuum ing out the fan squirrel cages around the motor and around the grills on the back of the stove IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding In structions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Grommet f To Remove U38 Fan 1 Unplug or disconnect power source to stove 2 Remove all logs and the rear log support then remove the 10 screws holding the access panel in place see Diagram 1 Fan is also accessible by opening the right side door See Diagram 2 3 Unclip the black and white wires from the fan motor N ao Unclip these or 2wires ge AI p P p we 1 D p oo p f 1 pa ai e A 1
26. e Sizes Natural Gas Propane Burner 81 50 Max Input Natural Gas Propane 40 000 Btu h 38 000 Btu h Min Input Natural Gas Propane 22 000 Btu h 20 000 Btu h Supply Pressure Natural Gas Propane min 5 w c min 12 w c Manifold Pressure Natural Gas 3 8 Propane 11 0 2 w c 0 2 w c Electrical 120 V 1 13A 60Hz Circulation Variable speed fan 125 75 CFM Log Set Ceramic fiber 7 per set System Data HIGH ELEVATION U38 NG For 2 000 4 500 feet altitude Burner Inlet Orifice Sizes Natural Gas Burner 33 Max Input Rating 36 000 Btu h Min Input Rating 19 000 Btu h System Data U38 Converted to 30 000 Btu Burner Inlet Orifice Sizes Natural Gas 37 Propane Burner 52 Max Input Natural Gas Propane 30 000 Btu h 30 000 Btu h Min Input Natural Gas Propane 15 000 Btu h 15 000 Btu h Supply Pressure Natural Gas Propane min 5 w c min 12 w c Manifold Pressure Natural Gas 3 8 Propane 11 0 2 w c 0 2 W C Electrical 120 V 1 13A 60Hz Circulation Variable speed fan 125 75 CFM Log Set Ceramic fiber 7 per set GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disconnect piping from valve at pres sures over 1
27. e label This unit has been convert ed to on top of the Serial decal over the Embers Embers higher Btu information 11 Check for gas leaks 12 Check inlet and outlet pressures 13 Check operation of flame control Check for 6 Remove burner orifice with a 1 2 wrench proper flame appearance and glow on logs and discard 10 Regency U38 ULTIMATE Freestanding Gas Stove INSTALLATION 3 Place Rear Log A 02 65 on the two pins on the rear log support 7 Place the Left Top Log D 02 46 on the pin on Log B 02 56 and on top of the cutout on Log A 02 65 Pins on Rear Log Support 4 Place the Middle Left Log B 02 56 on the two pins as shown Pin Cutout ee 8 Place Front Right Log E 02 45 on the two pins as shown 5 Sprinkle some lava rock just in front of B 02 56 on the burner holes 9 Place the lava rock in the area between the left and right logs leaving a space in the middle for log F 02 47 7 pr T SON lava rocks lava rock 6 Place Front Left Log C 02 44 onto the 2 front pins as shown l 10 Place the notch in Center Log F 02 47 over Log E 02 45 and across the cutout on Log A 02 65 gt F 02 47 i 4 mt Th a ee gt ES yg VIR a C 02 447 w AS Oy nn ad oo Cal i os j up Notch Cutout 11 Position notch in Front Right Log G 02 48 on Log F 02 47 and push the bottom right edge against the bracket on the burner tray Bracket
28. e rating instructions accompanying appliance push in or turn by hand don t try to repair it call ope g penyngepp LIGHTING INSTRUCTIONS STOP Read the safety information above on this label 1 Push in gas control knob slightly and turn clockwise to OFF Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 2 Wait five 5 minutes to clear out any gas If you then smell gas STOP follow B in the safety information above on this label If you don t smell gas go to the next step 3 Turn knob on gas control counterclockwise to PILOT 4 Push in control knob all the way and hold in Immediately push black button on spark igniter until pilot lights Continue to hold the control knob in for about 1 2 minute after the pilot is lit 1 Push in the gas control knob slightly and turn clockwise to OFF Do not force Regency U38 ULTIMATE Freestanding Gas Heater 5 Turn gas control knob counterclockwise to ON 6 Use rocker switch to operate main burner TO TURN OFF GAS APPLIANCE 2 Turn off all electric power to the appliance if You may shut off the pilot during prolonged non use periods to conserve fuel Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 3 and 4 If knob does not pop up when released stop and immediately call your service technician or gas supplie
29. er service agency or gas supplier A This appliance has a pilot which must be lighted by hand following the instructions below exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service techni cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate Do not touch any electric switch do not use any combustion and ventilation air CAUTION Hot while in operation Do not touch phone in your building Immediately call your gas supplier from a n lghbors phone Follow esse ine Severe Burns may result Due to high surface structions temperatures keep children clothing and If you cannot reach your gas supplier call the furniture gasoline and other liquids having fire department fammable vapors away Keep burner and control C Use only your hand to push in or turn the gasicompartment clean See installation and control knob Never use tools If the knob will not EE ni
30. he kit 15 Check operation of flame control Tighten screws securely 16 Check for proper flame appearance and Pull off the pilot cap to a the pilot glow on logs orifice Installer Notice These instructions must be left with the appliance Regency U38 ULTIMATE Freestanding Gas Heater INSTALLATION CONVERSION TO LOWER BTU RATING FOR U38 LOG SET INSTALLATION FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can interfere with the pilot operation THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS Natural Gas Conversion Kit 730 920 Contains Qty Part Description 1 904 240 Burner Orifice 37 Natural Gas 1 918 034 Decal Converted to 30 000 Btu 1 918 033 Instruction Sheet The gas log kit contains the following a 02 65 Rear Log 902 267 b 02 56 Middle Left Log 902 230 Propane Conversion Kit 730 922 c 02 44 Front Left Log 902 228 Contains E d 02 46 Left Top Log 902 231 Qty Part 4 Description e 02 45 Front Right Log 902 229 1 904 390 Burner Orifice 52 Propane 7 f 02 47 Center Log 902 232 1 918 034 Decal Converted to 30 000 Btu Burner Orifice g 02 48 MiddleRightLog 902 226 1 918 033 Instruction Sheet 7 Reinstall new burner orifice NG stamped h Embers 902 151 37 or LP stamped 52 and tighten i Lava 902 154 1 Shut off the gas supp
31. learances Use the minimum clearances shown in the diagrams below for installation with B vent U38 NG amp U38 LP Clearances A Side Wall to Unit B Back Wall to Unit E Side Wall to Unit 6 155 mm 2 50 mm U38 NG amp U38 LP REFERENCE DIMENSIONS C Back Wall to Flue Centerline 10 3 4 273 mm D Side Wall to Flue Centerline 20 1 2 520 mm F Side Wall to Flue Centerline 11 280 mm Minimum ceiling height is 36 914 mm from top of unit 914 mm 36 Minimum 7 1 2 190 mm OPTIONAL OUTSIDE AIR Outside air for combustion can be brought in either through the bottom of the pedestal or through the rear plate of the pedestal For both bottom and rear outside air the Ped estal Cover Plate must be installed Loosen the 4 screws on the rear of the pedestal and slide the cover plate over them Slide the plate to the left to center it and tighten down the 4 screws Outside Air Through Pedestal Bottom Once you have properly marked the position of your unit as outlined in General Information and Clearances to Combustibles cut a prop erly sized hole though the floor directly under your pedestal base to the outside Pipe fresh air into the pedestal area by using appropriate metallic duct pipe with a mesh grill at the outside termination Do not remove the knockout NONSENS PSSA ASSN Rear View Outside Air Through Rear of Pedestal Remove the blanking plate from the rear of the pede
32. llations above 2000 ft refer to current ANSI 2223 1 Sc8 8 1 2a appendix F for resizing orifice VENTING This heater is a vented appliance and must be connected to a chimney flue in accordance with the installation codes Note The rear pedestal cover plate is only required when outside air is being used If using room air for combustion remove this plate from the back of the pedesial For your safety this heater is equipped with a vent safety switch designed to sense incor rect venting and react by shutting down the gas supply This thermally actuated switch is located within the draft hood and will detect either a blocked chimney or backdraft condi tion where the chimney flow has reversed If this switch shuts the unit down it indicates a drafting problem that must be identified and rectified without delay the thermally activated switch must never be bypassed or discon nected as a hazardous or deadly condition can result Venting Requirements A four inch diameter vent is required B Vent Class A or Masonry with an approved liner are all acceptable For cosmetic or aesthetic pur poses 6 outer vent can be used as long as an approved inner vent is installed Fasten but do not penetrate the inner sleeve of the B Vent when tightening the screw Follow all venting manufacturer s requirements and local building codes In cold climates we recommend the use of insulated B vent chase and liners For altitudes above 2000
33. llivolt Thermostat Some areas may have further requirements check local codes before installation 4 This appliance is Listed for Alcove installa tions maintain minimum Alcove clearances as follows minimum ceiling height of 66 minimum width of 48 and a maximum depth of 36 5 This unitis not approved for installation into a mobile home 6 See general construction and assembly instructions 7 This appliance must be connected to a vent and terminate to the outside of the building envelope Never vent to another room or inside a building 8 Inspect the venting system annually for blockage and any signs of deterioration 9 Any safety glass removed for servicing must be replaced prior to operating the appliance 10 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 11 Wear gloves and safety glasses for pro tection while doing required maintenance 12 Under no circumstances should this appli ance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 13 Installation and any repairs to this appliance should be done by a qualified service per son A professional service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 14 Do not strike the glass door 15 Under no circumstances should any solid fuels wood paper cardb
34. lue Gas The thermally activated safety switch must be manually reset before first star tup OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired Connect the wires as per the wiring diagrams Note that the wires are connected to the TH on the gas valve Use table below to determine the maximum wire length Note Preferable if the thermostat is in stalled on an interior wall Regency offers an optional programmable ther mostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires 12 Regency U38 ULTIMATE Freestanding Gas Stove INSTALLATION Thermostat Wire Table Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 2 System OPTIONAL REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate This heater does not require a 120V A C supply for operation In case of a power failure the burner switch and the optional remote control thermostat will continue to op erate However a 120V A C power supply is needed for the fan blower operation 1 Choose aconvenient location on the wall to install the receiver and the receptacle box protection from extreme heat
35. ly j ve 8 Reverse steps 3 and 2 Note Install Optional Brick Panels prior to installing logs EN Sm 9 Adjust Vent restrictor setting To set the og logs and lava rock Vent restriction as indicated in the diagram A 02 65 D 02 46 G 02 48 simply loosen the screws and push the vent Al S REMOVE DUNEN GEE MAgrAr DEION restrictor plate to the correct position Tight en the screws Btu h Restrictor Opening 40 000 A 1 3 8 35mm U38 30 000 B 1 1 8 29mm Note Use a C 02 44 B 02 56 F 02 47 E 02 45 magnetic type i The 02 refer numbers i e 02 65 are screwdriver if possible molded into the rear of each log a eee High Bt Rat 7 Vent Restrictor i l u Rate Log Pins and move 9R Vent Position HA 1 Carefully remove the logs from the box and to the front hole Restrictor fully open unwrap them The logs are fragile handle position Plate with care do not force into position 5 Remove Rear Log Vent Restrictor setting at High 40 000 Btu h Bracket and slide 2 Sprinkle the embers on the left and right sides of the firebox base B B the Log Bracket Re strictor between the Rear Log Brack Hole for wa a et and the burner ow Btu Rate gt gt F B ia i E secure with the 2 Move Rear Log screws Pins forward to vent yt vege front holes Restrictor 99 0n Plate Vent Restrictor setting at Low 30 000 Btu h Rear Log Bracket 10 Attach th
36. nect the gas at the valve 7 Remove the burner by removing the two 1 4 hex head screws See diagram be low Note Use a magnetic type screwdriver 8 Remove eight 1 4 hex head screws hold ing the burner tray assembly in place 9 Carefully lift the burner tray assembly out Burner tray assembly after ie removed from the stove 10 To replace the burner tray assembly sim ply reverse these instructions Regency U38 ULTIMATE Freestanding Gas Heater 19 PARTS LIST 20 Part 960 920 960 922 960 055 730 034 730 51 7 P 910 331 P 910 794 730 039 904 257 960 025 730 530 730 525 960 031 904 258 948 255 U38 MAIN ASSEMBLY Description Part Top Bottom Gold Louver Assy Top Bottom Black Louver Assy Fan Access Door Gasket for Fan Access Door 25 27 28 30 32 Fan Assembly 33 Fan Motor 120 Volt 34 Power Cord 120 Volt 35 38 Pedestal Assembly Pedestal Door Pedestal Door Magnet Pedestal Back 910 250 910 233 750 010 730 565 960 535 990 273 990 930 820 058 948 216 918 026 Description Spill Switch Thermodisc Fan Auto On Off Mounting Bracket Fan Thermodisc Rear Panel Firebox Baffle False Top Assembly Flue Attachement Bracket Ult 6 Flue Collar Optional Pedestal Base Cover Logo Plate Manual Not available as a replacement part Short Side Panel Door Assy Right Side Short Side Panel Door Assy Left Side Hinge
37. oard coal etc be used in this appliance 16 The appliance area must be kept clear and free of combustible materials gases and other flammable vapours and liquids 17 Do not connect this gas appliance to chim ney flue serving a separate sold fuel burn ing appliance 18 WARNING Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the blocked vent shutoff system can result in carbon monoxide CO poisoning and possible death 19 This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm INSTALLATION CHECKLIST 1 Check Clearances to Combustibles page 6 2 If you are using outside air page 6 3 Install venting page 7 4 Make gas connections page 8 Test the pilot Must be as per diagram page 16 5 If necessary convert Natural Gas to Pro pane page 9 or convert to lower Btu page 10 6 Test Gas Pressure page 8 7 Install log set where indicated on page 10 8 ss Install Front Door page 12 Regency U38 ULTIMATE Freestanding Gas Heater INSTALLATION 9 Install Louvers page 12 10 Test for flue spillage draft test page 12 11 Install optional Remote Control or Wall Ther
38. ouvers and optional gold door may be scratched if abrasives are used to clean them The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint not with wall paint Regency uses StoveBright Paint Metallic Black 6309 3 Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem calla qualified service person 4 The appliance and venting system must be inspected before use and at least annual ly by a qualified field service person to ensure that the flow of combustion and ventilation air is not obstructed During the annual service call the burners should be removed from the burner tray and cleaned Replace the embers do not block the pilot or burner ports 5 Keep the area near the appliance clear and free from combustible materials gasoline and other flammable vapours and liquids WARNING CHILDREN AND ADULTS SHOULD BE ALERTEDTO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TOAVOID BURNS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFUL LY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE AP PLIANCE CAUTION ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV ICING AN APPLIANGE MUST BE REPLACED PRIOR TO OPERAT ING THE APPLIANCE CLOTHING OR OTHER FLAMMA BLE MATERIAL SHOULD NOT BE PLACED O
39. r If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier PILOT BURNER VEILLEUSE _ re Gas L ce Inlet 0 TLGA DB Ol THERMOPILE ELEMENT THERMO ELECTRIQUE service is to be performed OPERATING INSTRUCTIONS PILOT ADJUSTMENT Periodically check the pilot flames Correct flame pattern has three strong blue flames 1 flowing around the thermopile and 1 around the thermo couple and 1 flowing across the rear of the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contact your Regency dealer for further instructions Rear of Burner OOO 0000000 0000000000 0000000000 Thermopile of Burner Front Top View of pilot flame Incorrect flame pattern will have small proba bly yellow flames not coming into proper con tact with the rear of the burner or thermopile Rear of Burner AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude U38 with 40 000 Btu h U38 NG Natural Gas 1 4 open U38 LP Propane 1 2 open U38 with 30 000 Btu h U38 NG Natural Gas 3 16 open U38 LP Propane 3 8 open The aeration adjustment gears are located on the right side of the burner box and can be accessed from the side or from the front when the louvers are removed
40. r Complete 107 730 928 Gold Panel Door Complete 101 650 920 Door Gasket Kit 105 Ceramic Paper 106 940 323 P Side Glass 107 936 243 Glass Gasket 108 940 322 P Centre Glass 111 Door Frame Fibre Paper 112 750 015 Door Glass Extrusion 208 940 325 P Wrap Glass Not available as a replacement part PANEL DOOR 22 Regency U38 ULTIMATE Freestanding Gas Stove WARRANTY FIREPLACE PRODUCTS REGENCY Regency Fireplace Products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before itleaves our door Regency Industries Ltd is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product The Warranty Lifetime Covered under the agreement are the following components Combustion chamber heat exchanger burner tubes logs embers glass thermal breakage and all gold plating against defective manufacture The above will be covered for parts and labour for the first five years and parts only thereafter Electrical components such as blowers fan motor switches wiring thermodiscs remote control thermopiles thermocouples pilot assemblies and gas valves are covered for one year from the date of purchase Conditions All installations must be performed by a qualified gas fitter and installed according to all applicable local and national codes Also all service work must be carried out
41. remove the grounding prong from this plug Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Grounding _ Lug Detail Ground wire from fan Lockwasher Star washer Thermopile Star washer round wire from power cord Pilot Assembly In Gas mH possesses 1 Gore NY 1 white LI or E Thermostat 77 77575 S 1 T Valve Remote Transmitter Flue Spill Optional Switch Remote 2 sees Manual Reset Receiver o 577 O CAUTION Label all wires prior to discon nection when servicing con TI 120V AC x i 60Hz i m trols Wiring er rors can cause improper and dangerous op eration Electrode Thermocouple Rotary Speed Control Fan Thermodisc normally open Piezo Ignitor ON Burner OFF THERMOSTAT Regency U38 ULTIMATE Freestanding Gas Heater 13 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance proceed through the following check list 1 Read and understand these Instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the three pieces of door glass are properly positioned Ne
42. stal cover plate and bend the two tabs out 90 degrees Pipe fresh air into the pedestal area by using duct pipe with amesh grill atthe outside termination Attach the pipe to the tabs with screws Pedestal Cover LEN NSO ONS SAS Outside Air Kit BlankingPlate Removed amp Tab BentOut Side View If further reduced clearances are needed ob tain requirements for construction of a protect ed wall from your local building authorities and their allowable reductions of the listed clear ances 6 Regency U38 ULTIMATE Freestanding Gas Stove INSTALLATION DRAFT HOOD This heater has a draft hood built in It must not be altered obstructed or blocked in any way and the unit must be installed so that the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the burner This heater must be properly connected to a venting system This heater is equipped with a vent safety shutoff system WARNING Operation of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide CO poison ing and possible death HIGH ELEVATION The U38 with 40 000 BTU rating is approved in Canada for altitude 2000 ft to 4500 ft CAN CGA 2 17 M91 with the orifice kit Part 591 975 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 In U S A for insta
43. ts in damage to the exterior facia is not the responsibility of Regency Industries Ltd Note Warranty is not transferable Vent Components The venting components are under warranty from Simpson DuraVent Inc General It is essential that all submitted claims provide all of the necessary information including purchase date serial type of unit and part or parts requested Regency U38 ULTIMATE Freestanding Gas Heater 23 Regency fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our Vilde PEST Fireplace Products International Ltd is pleased to extend this Na Limited Lifetime Warranty to the VW original purchaser of a Regency Product See the inside back cover for details Register your Regency online at http www regency fire com Installer Please complete the following information Dealer Name amp Address Installer Phone Date Installed Serial No E a i fn ad af ie Ar
44. u with all the warmth and charm of a woodstove at the flick of aswitch The models U38 NG and U38 LP ofthis series has been approved by Warnock Hersey for both safety and efficiency Asit also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Gas Stove 17 5 8 448mm 17 432mm 10 3 4 273mm 3 8 NPT i gas line in a 4 collar 102mm 30 762mm Ee 1 17 432mm 3 1 2 89mm 26 660mm l bese ine U38 NG amp U38 LP We recommend that our products be installed and serviced by professionals who are certified in the U S by NFI National Fireplace Institute or Technical Training in Canada by WETT Wood Energy jun www nficertified org 2 Regency U38 ULTIMATE Freestanding Gas Stove TABLE OF CONTENTS Page Safety Label SEAT aaa ee nee ee een eee ee 2 SAGN Label seede eds 4 Installation General Installation Information rrrnnnrrrnnnnnrvrnnnnnnnnnrr 5 Installation Checklist Luisa ojeendsiesnsled hi Mdvidon 5 Minimum Clearances to Combustibles rrrrrrannrrerrrnnen 6 Optional Outside Air rrrrrrnrrrrrrrnnnrrrrrrrnnnrrnnrnnnnrrnnnnnnnee 6 Outside Air through Bottom of Pedestal 6 Outside Air through Rear of Pedestal 7
45. ver operate the appliance with any of the glass removed or with the door open 5 Verify that all venting and the cap is unob structed 6 Verify log placement If the pilot cannot be seen when lighting the unit the logs or the embers have been incorrectly positioned 7 The unit should never to turned off and on without a minimum of a 60 second wait LIGHTING INSTRUCTIONS IMPORTANT The PILOT knob cannot be turned from pilot to off unless it is partial ly depressed Note Open the pedestal door of the unit before lighting the pilot Once the pilot is lit close the door You should never operate the unit with the door open 1 If the PILOT knob is in the off position proceed to Step 4 Diagram 1 2 Pushin PILOT knob slightly and turn clock wise to off Knob cannot be turned from pilot to off unless knob is pushed in slight ly Do not force 3 Wait five minutes to allow gas that may have accumulated in the main burner com partment to escape If you smell gas fol low the instructions on the front of this manual If you don t smell gas continue on to the next step 4 Turn the PILOT knob counterclockwise to pilot and align it with the arrow as shown in diagram 1 5 Pushin PILOT knob all the way in and hold Immediately push IGNITOR button until pilot lights Continue to hold the PILOT knob in for approximately one minute then release the PILOT knob The pilot flame should continue to
Download Pdf Manuals
Related Search
Related Contents
gnuplot 3.5 ∗ User's Guide† Manuale per l`utente DIGITAL TORQUE METER MODEL TME2 distinguishing freehand drawing recognition for biometric instructions d`utilisation - Canadian Appliance Source Surveillance, Security & CCTV: A Buyer`s Guide QST External Tests User`s Manual - us モニタキット 使用手順 Tripp Lite Cat6 Gigabit Snagless Molded Patch Cable (RJ45 M/M) - Red, 2-ft. Copyright © All rights reserved.