Quantum Scalar 1000 User's Guide
Contents
1. Site Preparation OVERVIEW xn atr RAR e NEU A O Ra 5 3 Packaging Dimensions KK KK KK KK KK KK KK KK KK KK KK KK KK KK KK kK 5 3 General Information sa A A ta 5 4 Physical Environment 5 5 AdeessCondiHODS EER A te be ds 5 5 Additional Comments DES s 5 9 Index Contents V 22 June 2004 vi Contents 6 01150 01 Rev A Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 4 1 Control Module and Expansion Module 2 4 Storage Networking Fibre Channel Attachment Through an SNC si a rere rats 2 9 Direct SCSI Attachment 2 10 Network Attachment 2 12 Basic Library with No Expansion Modules 3 4 Library with One Expansion Module 3 5 Library with Two Expansion Modules 3 6 Library with Three Expansion Modules 3 7 Foot Pad Positions Control Module and Expansion Module 4 6 viii Figures 6 01150 01 Rev A Table 2 1 Table 3 1 Table 4 1 Table 4 2 Table 4 3 Table 4 4 Table 4 5 Drives and Storage Capacities 2 3 Library Configurations 3 3 Performance Specifications 4 3 Envi
2. The Scalar 1000 can be configured for approximately 118 to 1182 cartridges the cartridge capacity depends on the library configuration and features installed and 1 to 48 drives See Table 2 1 Table 2 1 Drives and Storage Capacities High Profile Low Profile 3590 DLT LTO DLT SDLT AIT Drives 1 16 1 48 1 48 1 48 Cartridges 118 788 140 938 118 788 237 1182 22 June 2004 General Description 2 3 Modules The Scalar 1000 Library has the following modules e Control Module CM on page 2 5 e Expansion Module EM on page 2 5 Door Lock Handle and Key Operator Panel Insert Eject Station Expansion Module Control Module Figure 2 1 Control Module and Expansion Module 2 4 System Description 6 01150 01 Rev A Control Module CM The CM is a single module standalone Scalar 1000 library It contains an LCD Operator Panel AC and DC power supplies robot control electronics and host interfaces It can be attached to an EM to create an expanded Scalar 1000 library See Figure 2 1 on page 2 4 The tape and drive bay capacity varies in the CM Each drive bay accommodates e One or two High Profile tape drives e One to six Low Profile tape drives e One to 12 Low Profile 8 mm AIT tape drives Expansion Module EM The EM extends the length of the a
3. 890 748 14 24 1122 3 4 748 Control 13 18 842 708 26 36 1062 5 6 708 Module and 19 24 794 688 38 48 1002 7 8 668 3 Expansion 25 30 746 628 9 10 628 Modules 31 36 698 588 11 12 588 37 42 650 548 13 14 548 43 48 602 508 15 16 508 Overview 3 3 22 June 2004 Configurations This section contains figures that show the four possible Scalar 1000 component configurations e Basic Library with No Expansion Modules Figure 3 1 e Library with One Expansion Module Figure 3 2 on page 3 5 e Library with Two Expansion Modules Figure 3 3 on page 3 6 e Library with Three Expansion Modules Figure 3 4 on page 3 7 60 in 1524 mm 30 in gt m mm Service 18 in Access 48 in 457 mm 1219 mm Eu 30 in d 762mm in p 305 TOM Y 138 in 3505 mm 60 in 3590 r 1524 mm 3590 125 in Fully Extended gt 47 in a ma I E Station 1193 8 mm LTO AIT j Control sprr prr i Module LTO AIT 30 in 762 mm Figure 3 1 3 4 System Configurations Basic Library with No Expansion Modules 30 in Y 762 mm 6 01150 01 Rev A 12 in 305 mm Fully Extended I E Station Figure 3 2 90 in 2280 mm 30 in 30 in 762 mm 762 mm i 18 in 457 mm 30 in 762 mm lt Y 138 in 3505 mm 60 in 3590 1524 mm 3590 125 in RN 3175 mm de n SDLT DLT Control Expansion m pen
4. LTO AIT Module Module LTO AIT 30 in 762 mm 30 in at 762 mm 22 June 2004 Library with One Expansion Module Configurations 3 5 12 in 305 mm 120 in Fully Extended I E Station Figure 3 3 3 6 System Configurations 3048 mm 30 in La in 30 in 762 mm 762 mm 762 mm 18 in 457 mm 30 in 762 mm lt Y 60 in Es 1524 mm 3590 47 in Control Expansion Expansion INA Module Module Module LTO AIT 30 in 762 mm 138 in 3505 mm 3590 125 in 3175 mm SDLT DLT LTO AIT 30 in E 762 S e Library with Two Expansion Modules 6 01150 01 Rev A 150 in 3810 mm BE i 30 in 30 in 30 i Mm Cte wn 762 mm 762 mm 762 Rg A in 457 mm 30 in 762 mm 12 in 305 mm my 138 in 3505 mm 60 in 3590 1524 mm 3590 125 in Fully Extended 7 m 47 in 3175 mm I E Stati 1193 8 mm SDLT DLT i did Control Expansion Expansion Expansion SDLT DLT LTO ATT Module Module Module Module LTO AIT 30 in 762 mm Y Y 30 in Had gt 762 mm Figure 3 4 Library with Three Expansion Modules Configurations 3 7 22 June 2004 3 8 System Configurations 6 01150 01 Rev A OVEIVIEW tn a Ne o rates neti 4 3 Performance Specifications 4 3
5. or warranty with respect to the contents of this document and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose Further ADIC Europe reserves the right to revise or change this publication without obligation on the part of ADIC Europe to notify any person or organization of such revision of change Every effort has been made to acknowledge trademarks and their owners Trademarked names are used solely for identification or exemplary purposes any omission is unintentional ADIC is a registered trademark and ADIC Europe is a trademark of Advanced Digital Information Corporation ADIC USA ADIC Europe ADIC Germany Beteiligungs GmbH KG Tel 1 303 705 3900 ZAC des Basses Auges Eschenstrafse 3 Fax 1 303 792 2465 1 rue Alfred de Vigny D 89558 ATAC 1 800 827 3822 78112 Fourqueux France B hmenkirch Germany www adic com Tel 33 1 3087 5300 Tel 00 800 9999 3822 Fax 33 1 3087 5301 Document number 6 01150 01 Rev A Published 22 June 2004 Printed in the USA ADIC CORPORATE 11431 WILLOWS ROAD NE REDMOND WASHINGTON USA 1 800 336 1233 ADIC 8560 UPLAND DRIVE ENGLEWOOD COLORADO USA 1 800 827 3822 ADIC 10 BROWN ROAD ITHACA NEW YORK USA 1 607 241 4800 Introduction Overview A A e eua 1 3 Intended Audience hh n 1 3 Organization 455x455 A A A E A EE ER ed 1 3 Associated DOCUMENES cc POP uer P pd UU PU SEER 1 4 ADIC Technical Assistance Cen
6. Describes general information Scalar 1000 library modules I O status and control and host attachments Chapter 3 System Configurations Describes the structure of the basic Scalar 1000 library and available optional components Chapter 4 System Specifications Describes the physical and electrical specifications of the Scalar 1000 components 1 Scalar 1000 is a trademark of ADIC Throughout the remainder of this document we refer to Scalar 1000 library as Scalar 1000 or the library Overview 1 3 22 June 2004 1 4 Chapter 5 Site Preparation Provides forms for planning space physical electrical and environmental requirements This information is required by the installation team Associated Documents 6 00054 xx Scalar 1000 Operator Guide 6 00055 xx Scalar 1000 SCSI Reference Manual 6 01151 xx Scalar 1000 Maintenance Guide ADIC Technical Assistance Center Introduction If problems cannot be solved with the aid of this document or if recommended training is desired contact the ADIC Technical Assistance Center ATAC Inthe USA 800 827 3822 e Outside the USA toll free 00 800 9999 3822 email support adic com 6 01150 01 Rev A System Description General DES rip HO sec pt ate Aire wld iets ie at 2 3 Modules xxr ds eres dai rtg obe rece A dit SE 2 4 Control Module CM oir aka n Bb geed Kaban heo ES 2 5 Expansion Module EM a 2 5 Int
7. Environmental Specifications 43 Electrical Specifications 4 4 Physical SpecificaHonNS ee e E e Reg ove al tet ed 4 5 Foot Pad POSIHODS s k sis ER EER dj DER RR DR ER EER EE gu dia 00k 0 000k 8 iste ee 4 6 Barcode Requirements 4 7 2 System Specifications 6 01150 01 Rev A Overview This chapter contains performance environmental electrical and physical specification information for the Scalar 1000 library The information is organized as follows e Performance Specifications on page 4 3 e Environmental Specifications on page 4 3 e Electrical Specifications on page 4 4 e Physical Specifications on page 4 5 e Foot Pad Positions on page 4 6 e Barcode Requirements on page 4 7 Performance Specifications The Scalar 1000 has peak actions per hour of 350 exchanges and peak time to mount media of 6 seconds Table 4 1 Performance Specifications Avg Actions Peak Actions Avg Time to Max Time to per Hour per Hour Mount Media Mount Media 290 350 5 Seconds 6 Seconds Environmental Specifications Table 4 2 lists the key environmental information for the Scalar 1000 library Specifications do not include drives Table 4 2 Environmental Specifications u i Maximum BTU Heat Temperature Humid
8. Specifications dock height type of ramps weather protection etc 5 6 Site Preparation 6 01150 01 Rev A Semitrailer Accessibility Y or N Preferred Required Local Carrier Company Where Can Trailer Be Left for Staging Availability of Material Handling Equipment Location for uncrating Preferred Time of Day for Unloading and Moving Materials Physical Environment 5 7 22 June 2004 Off Hours Weekends Accessibility for Installation Team Procedure for Obtaining Building Passes Procedure for Scheduling the Elevator Loading Dock etc Waste Disposal Considerations Bargaining Unit Considerations 5 8 Site Preparation 6 01150 01 Rev A Other Considerations Additional Comments Record any additional information from other pages For reference purposes note the page number with the information Add and number additional sheets as necessary Physical Environment 5 9 22 June 2004 5 10 Site Preparation 6 01150 01 Rev A Access Conditions Additional Comments Assistance with Problems Associated Documents Barcode Requirement Cartridge Accessor Chapter Organization Control Module Electrical Specificatio
9. The Scalar DLC attaches to the library SCSI bus The host continues to directly attach to the drives through a SCSI or a Fibre Channel Interface For more information on Scalar DLC including detailed information on the supported interfaces refer to ADIC Scalar DLC documentation See Figure 2 4 on page 2 12 for more information Scalar DLC Option 2 11 22 June 2004 Scalar 1000 mek Library Control Controller Expansion ADwwas B Drives C Drives Module Scalar SCSI DLE Channel Host Connections TEPIP for Library Requests Application Servers Figure 2 4 Network Attachment Remote Management Unit The factory installed Remote Management Unit RMU in each system uses a standard web browser for remote library access The supported browsers are e Microsoft Internet Explorer version 4 0 and above e Netscape Navigator version 4 7 and above With an RMU you are able to do the following e Update RMU firmware e Access the library status Make configuration changes 2 12 System Description 6 01150 01 Rev A e Access the library Operator Panel e Access Scalar 1000 documentation e Retrieve library command and event logs The RMU supports Simple Network Management Protocol SNMP version 2 0 and acts as an SNMP server The RMU acquires Tape Alert 3 0 compatible information from the library over the serial interface port and sends that information to a SNMP ma
10. adic Scalar 1000 Library Planning Guide 63 Advanced Digital Information Corp Copyright Notice 2002 2004 ADIC The information contained in this document is subject to change without notice This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without prior written consent of ADIC ADIC shall not be liable for errors contained herein or for incidental or consequential damages including lost profits in connection with the furnishing performance or use of this material whether based on warranty contract or other legal theory All trademarks are the property of their respective owners Copyright Notice Europe 2002 2004 ADIC Europe All rights reserved No part of this document may be copied or reproduced in any form or by any means without prior written permission of ADIC Europe ZAC des Basses Auges 1 rue Alfred de Vigny 78112 Fourqueux France ADIC Europe assumes no responsibility for any errors that may appear in this document and retains the right to make changes to these specifications and descriptions at any time without notice This publication may describe designs for which patents are pending or have been granted By publishing this information ADIC Europe conveys no license under any patent or any other right ADIC Europe makes no representation
11. age arrays or tape drives that may be installed in the Library Refer to the Scalar 1000 Operator Guide for a list of all fiducial labels 6 01150 01 Rev A r Note Duplicate barcode labels even with different media identifiers are NOT supported e An X Axis drive for moving the Cartridge Accessor the length of the rails in the CM and the EMs e A Y Axis drive for moving the Gripper Assembly vertically in the CM and the EMs Tape Cartridges The Scalar 1000 automates the retrieval storage and control of 3590 DLT SDLT LTO and AIT cartridges Two characters are used to identify the cartridge type For SDLT and LTO cartridges the media identifier is embedded at the end of the barcode label Any code 39 labels are supported Refer to the Scalar 1000 Operator Guide for more information on label types supported by the Scalar 1000 Insert Eject Station The I E Station allows for the insertion and ejection of cartridges without interrupting the normal operation of the library The I E Station uses two different cartridge magazines One magazine has a capacity of six half inch cartridges 3590 DLT SDLT LTO the other magazine has a capacity of nine 8 mm AIT cartridges A maximum of two magazines of any type can be present in the I E Station at any time If you have two different magazines in an I E Station such as one half inch and one 8 mm magazine the library requires Scalar DLC Fo
12. ernal Components isson ies a rr 2 6 Tape DrIVES gin a ee cal did 2 6 Cartridge Accessori A EE HE 2 6 Tape Cartridges ii pt a pre e UM rer pi eene Supe gnili 2 7 Insert Eject Station cer rcr rer erre ped d Ra edes 2 7 Connectivity ds easi A 2 8 SAN CONNE TIVItY Jo scu ger a ei AGIR Eg Rue 2 8 SESE COrnnecHvity 40 x55y 2223 eer E laa ae Da E Se Eu abge ees duet 2 10 Scalar DEC Option isses ee e eere ee 2 11 Remote Management Unit 2 12 2 System Description 6 01150 01 Rev A General Description CF Note To accommodate IBM 3590 drives you must add an Extension frame to a Control Module oran Expansion Module to increase module depth The Scalar 1000 automates the storage retrieval and control of 3590 LTO DLT SDLT and AIT tape cartridges Tape cartridges are mounted and dismounted in tape drives using application software from the host without operator intervention The Scalar 1000 is a linear storage library that can be expanded from a single media library to a mixed media library The Scalar 1000 consists of a Control Module CM and up to three Expansion Modules EMs See Figure 2 1 on page 2 4 The CM contains library control hardware the Cartridge Accessor an Insert Eject Station I E Station an Operator Panel cartridge storage cells and tape drives The EM can contain tape drives and cartridge storage
13. erview This section solicits pertinent information about the delivery site Record all requested general information Packaging Dimensions The Scalar 1000 module packaging sizes are as follows e Control Module CM packing size 65 in L 1651 mm x 35 in W 889 mm x 78 in H 1981 mm and mounted on 150 lb palettes e Expansion Module EM packing size 65 in L 1651 mm x 35 in W 889 mm x 78 in H 1981 mm and mounted on 150 lb palettes Overview 5 3 22 June 2004 5 4 General Information CF Note Customer Name Place any additional information in Additional Comments on page 5 9 Mailing Address Shipping Address Sales Contact Telephone ADIC Sales Rep ADIC Account Mgr Installation Contact Telephone Target Installation Date Site Preparation 6 01150 01 Rev A Target Operational Date Physical Environment Place any additional information in Additional Comments on page 5 9 Room Dimension Ceiling Projection Floor Type Floor Load Capacity Fire Protection Access Conditions Access to Scalar 1000 library room elevator stairs door widths etc Physical Environment 5 5 22 June 2004 Dimensions and Location of Smallest Door or Opening Loading Dock
14. ev A Barcode Requirements For customers who want to print barcode labels the labels must meet the ANSI MH10 8M 1983 standard and other additional requirements The following list outlines the ANSI MH10 8M 1983 standard and additional requirements e ANSI MH10 8M 1983 Standard Number of digits e 5 16in extended mode e 6 7 or 8 including media characters in default and mixed media modes Background reflection at least 25 percent Print contrast at least 75 percent Ratio at least 2 2 Module 250 mm Print tolerance 57 mm e Additional requirements Length of the rest zones 5 00 mm minimum No black marks can be present in the intermediate spaces or rest zones No white areas may be present on the bars A nine digit bar code must not match the serial numbers of any frames of the unit otherwise it will be ignored Each label should be applied in the upper right corner of the tape cartridge recess when oriented vertically Barcode Requirements 4 7 22 June 2004 4 8 System Specifications 6 01150 01 Rev A OVEIVIEW VaR OLPC 5 3 Packaging Dimensions SE KK KK n 5 3 General Information EE RE ee elas DR eR De eee Sid MJ N Did 5 4 Physical Environment aeiia ei ee ee ee ee ee ee ne 5 5 Access Conditions 1 A es ees 5 5 Additional Comments o 5 9 2 Site Preparation 6 01150 01 Rev A Ov
15. isle and adds drives and cartridges to the library The Scalar 1000 maximum configuration includes three EMs These modules extend the X rails top and bottom which allow the Accessor to travel the length of the library See Figure 2 1 on page 2 4 22 June 2004 Modules 2 5 2 6 Internal Components The Scalar 1000 consists of the following internal components System Description Tape Drives Cartridge Storage Cartridge Accessor Tape Cartridges Insert Eject Station Tape Drives The Scalar 1000 supports the following tape drives 3490E NCTP 3590 DLT high profile and low profile SDLT AIT 1 AIT 2 AIT 3 LTO 1 LTO 2 Cartridge Accessor The Cartridge Accessor identifies and moves cartridges between the storage cells tape drives and the I E Station The Cartridge Accessor has A Gripper Assembly for getting and putting cartridges in storage cells tape drives or the I E Station A Barcode Scanner for reading the external barcode labels on the cartridges The Barcode Scanner is used during the inventory process to locate and categorize all cartridges installed in the library It is also used during the teaching process in which it reads the fiducial labels to identify the types of storage arrays and tape drives installed in the Library Fiducial labels are barcode labels located on tape drives and storage arrays Each label has a different value to identify the various types of stor
16. ity Altitude Dissipation Operating Non condensing 60 90 F 16 32 C Operating No Limit 0 44 kwh 15 75 1502 BTU Recommended Recommended 70 75 F 21 24 C 45 6596 Overview 4 3 22 June 2004 4 4 Electrical Specifications The electrical specifications for the Control Module CM and Expansion Module EM are shown in Table 4 3 Table 4 3 Electrical Specifications Voltage United States module Single Phase KVA Power Connector CM EM 115 230 1 6 L5 20 International Power Connector Plug is customer supplied a Connect an 18 gauge stranded copper wire from the CM to earth ground The typical power consumption for a full height half height drive and the SNC 5100 is shown in Table 4 4 Table 4 4 Typical Component Power Consumption Worst Case System Specifications Component Status Watts BTU Full Height Drive Read Write 71 5 244 Idle 53 0 180 Half Height Drive Read Write 53 8 263 Two in sled AIT Idle 24 6 120 SNC 5100 Read Write 33 113 The EMs only need power if there are drive bays installed 6 01150 01 Rev A Physical Specifications The physical specifications for the library modules are shown in Table 4 5 The floor must support point loads exerted by the leveling pads of up to 86 42 Ib in In addition to being dust free physically chemically and acoustically a
17. nager The RMU also detects a power loss and generates a SNMP trap for notification For additional information refer to the Scalar 1000 Operator Guide Remote Management Unit 2 13 22 June 2004 2 14 System Description 6 01150 01 Rev A DV EEVA EV ta A No EE BA EE Ee ei ins DA co 3 3 Gonfigurations EE seus ti a ir vb be eed etes Han 3 4 2 System Configurations 6 01150 01 Rev A Overview CF Note Service requires 48 in 1219 mm access This chapter describes the Scalar 1000 library component configurations The Scalar 1000 can consist of one to four modules a Control Module and up to three Expansion Modules See Table 3 1 for module tape drive and tape cartridge configuration information Table 3 1 Library Configurations LTO DLT SDLT AIT 3590 Drives Cartridges Drives Cartridges Drives Cartridges LTO DLT SDLT LTO DLT SDLT Control 1 6 188 158 2 12 237 12 158 Module 7 12 140 118 Control 1 6 438 368 2 12 552 1 2 368 Module and 7 12 390 328 14 24 492 3 4 328 1 Expansion 13 18 342 288 5 6 288 Module 19 24 294 248 7 8 248 1 6 688 578 2 12 867 1 2 578 Control 7 12 640 538 14 24 807 3 4 538 Module and 13 18 592 498 26 36 741 5 6 498 2 Expansion 19 24 544 458 7 8 458 Modules 25 30 496 418 9 10 418 31 36 448 378 11 12 378 1 6 938 788 2 12 1182 1 2 788 7 12
18. ns Environmental Specifications Expansion Module Foot Pad Positions Control Module Expansion Module General Description General Information Insert Eject Magazines Index Insert Eject Station 2 7 Intended Audience 1 3 O Operator Panel 2 3 P Performance Specifications 4 3 Physical Environment 5 5 Physical Specifications 4 5 R Remote Management Unit 2 13 S SAN Connectivity 2 8 S lar DEC 31 5 ee eret ares S254 2 11 SCSI Connectivity 2 10 SNMP rte Acad 2 13 Specifications Electrical Specifications 4 4 Environmental Specifications 4 3 Performance Specifications 4 3 Physical Specifications 4 5 Storage Cells dere ee RES 2 3 zT Tape Cartridges 2 7 Technical Assistance 1 4 in 2 Index 6 01150 01 Reo A
19. ppropriate the flooring must meet the insulation resistance specifications The insulation resistance between the floor surface and earth ground must be 1x10 to 1x10 ohms to prevent system failure or electrical shock Sufficient resistance is achieved by using antistatic nonconducting floor tile with a resistance of 1x10 to 1x10 ohms If necessary provide an appropriate connection to the metal portion of the ground plane The Scalar 1000 has four point loads on the CM and EM Table 4 5 Physical Specifications Maximum Distributed E Height Width Depth Weight Load Point Load Control Module 72 in 29 6 in 47 in 1052 Ib 85 Ib ft 86 42 lb in 1828 8 mm 751 8 mm 1193 8 mm 477 Kg 414 Kg m 421 88 Kg m SDLT DLT LTO AIT 60 in 1524 mm 3590 Expansion Module 72 in 29 6 in 47 in 817 lb 66 00 Ib ft 67 11 Ib in 1828 8 mm 751 8 mm 1193 8 mm 371 Kg 322 2 Kg m 327 Kg m SDLT DLT LTO AIT 60 in 1524 mm 3590 Physical Specifications 4 5 22 June 2004 Foot Pad Positions The Scalar 1000 foot pad positions are shown in Figure 4 1 The foot pad positions are the same for the CM and EM lt q 29 65 in 753 2 mm gt 46 71 in Yen 1186 4 mm 09 in 1043 8 mm 4X 2 00 in 50 8 mm Y V Figure 4 1 Foot Pad Positions Control Module and Expansion Module 4 6 System Specifications 6 01150 01 R
20. r more information on Scalar DLC refer to Scalar DLC Option on page 2 11 or contact an ADIC representative The coordinate for the rows in the old style I E Station is always contiguous 1 to 12 for half inch and 1 to 18 for 8 mm Since two magazines of different cartridge types can be present in the I E station at any time the first cell of the bottom magazine of the new style I E station always starts with Row 10 Internal Components 2 7 22 June 2004 2 8 Connectivity System Description The Scalar 1000 offers several different connectivity options allowing the library to support a wide range of backup topologies and applications Flexible library connectivity delivers active support for loop and switched fabric Fibre Channel protocols along with SCSI SAN Connectivity The Scalar 1000 can be connected to a Fibre Channel Storage Area Network SAN via the Storage Networking Controller SNC The SNC provides four parallel SCSI bus connections one ethernet and two Fibre Channel connections The SNC allows native SCSI devices for example robot controller and tape drives to be seen by any hosts that are attached to the SAN The library controller and the tape drives access the SAN via the SNCs that can be installed in a Scalar 1000 CM or EM See Figure 2 2 on page 2 9 6 01150 01 Rev A Scalar 1000 __ SCSI Connections __ Fibre Channel Connection
21. ronmental Specifications 4 3 Electrical Specifications 4 4 Typical Component Power Consumption Worst Case 4 4 Physical Specifications 4 5 x Tables 6 01150 01 Rev A OVEIVIEW ET E A A E A AN 1 3 Intended Audience velo tai a preda mau make ER 1 3 Organization 5r reote ee edet AI AGE Sate ASA AS 1 3 Associated DOCUMENTS eR e bue E bes di Pace oen 1 4 ADIC Technical Assistance Center 6 s e e 1 4 2 Introduction 6 01150 01 Rev A Overview This chapter provides general information on this manual including intended audience organization associated documents and where to acquire technical assistance The information in this chapter is organized as follows e Intended Audience on page 1 3 e Organization on page 1 3 e Associated Documents on page 1 4 e ADIC Technical Assistance Center on page 1 4 Intended Audience This manual is for sales personnel and potential purchasers of the Scalar 1000 library Organization This manual contains information detailing the Scalar 1000 library The chapters include Chapter 1 About this Guide Describes the intended audience organization associated documents and where to acquire additional assistance Chapter 2 System Description
22. s Fibre Channel z Switch Application Servers Figure 2 2 Storage Networking Fibre Channel Attachment Through an SNC Connectivity 2 9 22 June 2004 SCSI Connectivity The Scalar 1000 can be directly connected to one or two SCSI buses Because each SCSI bus is independent it can be Single Ended High Voltage Differential or Low Voltage Differential Both ends of each bus must be terminated and a terminator is shipped with each SCSI adapter card ordered The minimum configuration of a Scalar 1000 library requires one SCSI adapter and the SCSI type Single Ended High Voltage Differential or Low Voltage Differential Although the Scalar 1000 can be attached to a wide SCSI bus it is not a wide SCSI device and its SCSI ID must be in the range of 0 to 7 See Figure 2 3 Scalar 1000 Library Controller SCSI l EE ll a an a l AA e es Application Server Figure 2 3 Direct SCSI Attachment 2 10 System Description 6 01150 01 Rev A Scalar DLC Option The Scalar 1000 through its optional Scalar Distributed Library Control Scalar DLC interface provides the industry s most advanced combination of management and diagnostics The Scalar DLC software serves as a centralized library management tool that simplifies and automates the tracking and management of all system resources for optimal performance and maximum availability
23. ter 1 4 System Description General Description 4521003 bone EE TOP A GS RAE RE SG das dada 2 3 Modules s 2 4 Control Module CM Ea Ewa kad Wa wa an Se a wek Wk W ee 2 5 Expansion Module EM sanse a 2 5 Internal Components dya taAa ANE MENER EE EE EE EE EA ee 2 6 Tape Drives ti O AS 2 6 Cartridge AOCESSOT yek 142 TE EE EE EE ER 2 6 Tape Cartridges Es ESEL DE GE oi E as fel iA Ere 2 7 Insert Eject Station viii vectus ac eae r bb 2 7 CONNECHVILY eite Eg RR HORE RO da dde ud eed di s mu dan 2 8 SAN CONNECTIVITY s c eoe Tu reete Ee EE REN EE GE aida 2 8 SCSI Connectivity ker b RA ee ERR Nk ed ie Vie a eoe a GE 2 10 Scalar DEC Option isses EERS EE a eee mer e a al sessi be gas px ep 2 11 Remote Management Unit 2 12 System Configurations OVerVleW nis 24 eter ek M eb bi si salt REO ER URP REA IRE RE qu E vu EE 4 3 Performance Specifications 4 3 Environmental Specifications 4 3 Electrical Specifications 4 4 Physical Specifications iese kena a en 4 5 Foot Pad Positions eon tese DER RD EER I qup ue ded ex X 4b b 4 6 Barcode Requirements 11 44 romid a este d Vios ee h v Piai 4 7 iv Contents 6 01150 01 Rev A