Home

Quantum Instruments MS3580 User's Manual

image

Contents

1. 1 8 33 Stand Alone Keyboard 1 11 Troubleshooting 27 30 USB steuer 1 12 34 38 IR Activation Range Noa 26 AT 2 26 K Keyboard Country Type 33 Keyboard Type 33 Keyboard Wedge 10 30 34 38 L Label Caution eere rns 5 Serial Number 5 EE 44 Laser Aperture 4 Laser Emulation 8 34 38 lE Dua tette tec 19 21 Light Pen 8 34 38 Light Source 31 M Maintenance ccccococcccncnnnncnnonoconnnns 5 Manual 2 19 33 INDEX MetroSet2 AA 39 Mode of Operation Bunton are 18 Primary ccce 13 18 Secondary 13 18 Sweet Spot Mode ee 38 Motor Gpeed 31 Mounting Specifications 5 N Notices sssssssssseee 45 O OGIA icti 9 34 38 Omnidirectional 13 18 Operation 45 P Patents rite etg 47 PG Ido nox 33 43 Pin Assignments Cable aces 42 43 SCANNED unse 40 41 POM ziii traer 8 12 27 30 POWED acceca 2 8 12 39 Power jmk 8 12 Product Safety oooooonioccccnnnnnicccccco 44 Property 2 eerie tees 47 Protocol ih Ert 33 R RAM 2 ee 29 E 13 18 Razzberry Tone 19 21 29 Rep if rc 21 Replacement Parts 3 RMA nee 46 ROM erret 29 RS232 u 8 29 30 34 38 RS232 TIL 8 33 S Scan Liries ees 31 S
2. je gt EEE E E E E E E E EEE EE E E E WE xx Y LO eo co oa WOW o oz co e N o O FTN o Se e N N N were xf ng i MET d B Figure 16 Normal Scan Zone by Bar Code Element Width All specifications are subject to change without notice 24 SCANNER OPERATION Depth of Field by Bar Code Element Width Reduced Scan Zone 101 mm 4 114 mm 4 5 146 mm 5 75 19 mm 75 25mm 1 38 mm 1 5 Figure 17 Reduced Scan Zone by Bar Code Element Width All specifications are subject to change without notice 25 SCANNER OPERATION IR Activation Range QuantumT s default power save mode is Laser OFF This power save mode turns the laser off after a configured period of non use Any movement detected by the IR in the activation area will cause the scanner to exit power save mode The laser will automatically turn back on preparing the scanner for bar code recognition decoding and transmission Normal 247 mm 9 75 o E E Activation Area Reduced Figure 19 Reduced IR Activation Range All specifications are subject to change without notice t Refer to the MetroSelect Configuration Guide 00 02407 for additional information on configurable power save modes 26 TROUBLESHOOTING GUIDE The following guide is for reference purposes only Contact a Metrologic representative at 1 800 ID METRO o
3. Metrologic METROLOGIC INSTRUMENTS INC MS3580 QuantumT Installation and User s Guide v Copyright 2005 by Metrologic Instruments Inc All rights reserved No part of this work may be reproduced transmitted or stored in any form or by any means without prior written consent except by reviewer who may quote brief passages in a review or provided for in the Copyright Act of 1976 Products and brand names mentioned in this document are trademarks of their respective companies TABLE OF CONTENTS Introduction Product Overview ae iii 1 Scanner and Accessories nennen nnnnnnnnnn nennen nennen 2 Scanner Components Musicos la Rise 4 Caution and Serial Number Labele 5 Cable Removal 5 2 4035 eee eae e ee o eee dese en 5 Maintenance ee tipa tura reat einer 5 Mounting Specifications and Stand Assembly sse 6 Installation RS232 RS232 TTL Light Pen or Laser Emulation en 8 IBM 46xx or OCIA anne EER e bannen 9 Keyboard UE e EEN 10 Stand Alone Keyboard Wedge sse eee 11 Full Speed or Low Speed USB Integrated nn nnnnen nennen 12 Scanner Operation Configurable Primary and Secondary Scan Pattern Modes 13 Configurable Button FUNCTIONS ernennen nenn 13 Indicators puc 19 MWASU eI tos extents starter portals 20 F llure 2 Serge ee tM ete edle e tne sfr 21 Depth of Field Specifications Normal Scan Zonen eigene dee etes 22 Reduced Scan ZOne een age st
4. ser del esc ner Ni intentar mirar al haz del l ser incluso cuando este no est operativo Tampoco deber abrir el esc ner para examinar el aparato El hacerlo puede conllevar una exposici n peligrosa a la luz de l ser El uso de instrumentos pticos con el equipo l ser puede incrementar el riesgo para la vista IN Attention L emploi de commandes r glages ou proc d s autres que ceux d crits ici peut entrainer de graves irradiations Le client ne doit en aucun cas essayer d entretenir lui m me le scanner ou le laser Ne regardez jamais directement le rayon laser m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous exposez une rayonnement laser q st hazardous L emploi d appareils optiques avec cet quipement laser augmente le risque d endommagement de la vision Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen Einstellungen oder Verfahren kann eine gef hrliche Laserstrahlung hervorrufen Der Kunde sollte unter keinen Umst nden versuchen den Laser Scanner selbst zu warten Sehen Sie niemals in den Laserstrahl selbst wenn Sie glauben da der Scanner nicht aktiv ist ffnen Sie niemals den Scanner um in das Ger t hineinzusehen Wenn Sie dies tun k nnen Sie sich einer gef hrlichen Laserstrahlung aussetzen Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung IN Attenzion
5. 23 Depth of Field by Bar Code Element Width Normal Scan ZOMG x ege piar parda atapi late 24 Reduced Scan Zone essen noise 25 IR Activation Range Deni EET 26 Reduced E ea 26 TABLE OF CONTENTS Troubleshooting Guide rn een Eed 27 Design Specificationis EE 31 Applications and Protocols seeeene emm eee 33 Default Settings Communication Parameters sese 34 Upgrading the Flash ROM Firmware 39 Scanner and Cable Terminations ene 40 Scanner Pinout Connections ooooonoccccnnnoccnononoccnononcncnono cnn nnnrn nn nano n een 40 Cable Connector Configurations Host End 42 Laserand Product Safety 44 Limited Warranty ivonne anne 46 Pd e e EE REED RE 47 let 48 Contact Information and Office Locations 50 INTRODUCTION The QuantumT is a hands free omnidirectional bar code scanner with optional single line scanning capabilities It utilizes the powerful Metrologic QuantumE scan engine to provide an outstanding scan performance on all standard 1D barcode symbologies including RSS This fully enclosed scanner includes large easily visible LEDs and a rugged protective boot with an adjustable stand The QuantumT can be mounted to a countertop wall or be left free standing for handheld scanning Key Product Features Fully Automatic Scanning Operation Single Line Mode for Menu Reading Custom Configurable Sc
6. Base Plate Cover Base Plate E 8 Wood Screws Figure 7 Assembling the Optional Flex Stand INSTALLATION RS232 RS232 TTL Light Pen or Laser Emulation 1 Turn off the host device Plug the male 10 pin RJ45 end of the PowerLink cable into the 10 pin socket on the MS3580 Connect the 9 pin female end of the PowerLink cable to the host device Plug the external power supply into the power jack on the PowerLink cable Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet The outlet must be located near the equipment and be easily accessible Connect AC power to the transformer Turn on the host device Figure 8 E When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication to occur enabled If the Recall Defaults bar code is scanned while reconfiguring the scanner laser emulation will no longer be enabled Scan the Laser Emulation barcode in Section J Laser Emulation of the MetroSelect Configuration Guide to re enable the laser emulation interface This feature is only supported for MS3580 104 models The MS3580 104 leaves the factory with t
7. LASER PARAMETER DEFAULT OCIA USB RS232 PEN 46XX KBW Stoen Nixdorf ID Transmit AIM ID Characters STX Prefix ETX Suffix Line Feed disabled by default in KBW FL Laser Enable Command 977 2 digit Supplemental Requirement 37 DEFAULT SETTINGS COMMUNICATION PARAMETERS RS232 OR LIGHT IBM LASER PARAMETER DEFAULT OCIA USB RS232 Pen 46XX KBW EMULATION TTL Supplements are not Required 100 msec to Find 1 Supplement 1 H Programmable in gt Y 100msec steps MAX 800 msec Coupon Code 128 Programmable Code 7 avail Lengths Programmable Prefix Characters Programmable Suffix Characters E Prefixes for individual Code Types Inter Scan Code Delay g00 E E E E E Programmable ase 1 E 1 E PY 100 usec steps E E 1 E 1 Minimum Element Width Programmable in 5 6 usec Normal Depth of Field Reduced Depth of Field 38 UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic s new line of Flash based scanners This program allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of firmware It requires the use of a personal computer running Windows 95 or greater and the use of a serial port The user merely connects the scanner to a serial port on the PC launches the MetroSet2 program and
8. Voltage according to EN IEC 60950 To maintain compliance with standard CSA C22 2 No 60950 UL 60950 and norm EN IEC 60950 the power source should meet applicable performance requirements for a limited power source SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the MS3580 The primary scan pattern mode is the default scan pattern active when the scanner starts The secondary scan pattern mode is activated by pressing the button located on the side ofthe scanner This mode is also referred to as the button mode For additional information on Quantum s button modes and an example of each please refer to Configurable Button Functions below The scanner returns to the primary scan pattern mode after a double click of the button or if the unit has not scanned a bar code for the duration of a pre configured time limit Each pattern mode can be configured to use one of three scan patterns listed below Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings e all scan lines on omnidirectional reading e Single line menu reading e horizontal raster If CodeGate is enabled it will apply to the secondary pattern mode when scanning For detailed information on CodeGate and the button refer to the Configurable Button Functions Configurable Button Function
9. a faint click when the cable lock is released Pull gently on the strain relief of the PowerLink cable to remove it from the scanner Smudges and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning 1 Spray glass cleaner onto a lint free non abrasive cleaning cloth 2 Gently wipe the scanner window INTRODUCTION Mounting Specifications and Stand Assembly Pedestal Stand Drill two 39 pilot holes for the two 8 wood screws Pivot Cylinder provided 4 FAN TEN 9 E Pedestal Base See Mounting Hole Detail Align Slots Mounting Hole Detail for the Pedestal Stand and Tabs Figure 4 Pedestal Stand Assembly Optional Flex Stand Length of the Flexible Shaft and Shaft Cover are Kit Dependent Kit Number Length of Flexible Shaft and Flexible Shaft Cover 46 00288 RES SO ASI 46 00289 i 6 inches INTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Drill four 39 pilot holes in the pattern shown Then use the KE 14 ESL four 8 wood screws provided mat i i to secure the base plate to the 8 Wood Screws countertop 508 200 I en 50 8 2 00 Dimensions mm inches MS3580 Pole Mount Adapter Pivot Cylinder Flexible Shaft Cover Align the Bearing Plate Tab Flexible Shaft and the Notch in the Base Plate Cover Bearing Plate
10. customer service representative for additional information on the MVC cable series and the host connections available Other items may be ordered for the specific protocol being used To order additional items contact the dealer distributor or call Metrologic s customer service department at 1 800 436 3876 INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES EN 54540003 ee en relief 5454020 3 2 m 7 ft straight cord short strain rele Bees pma ru en ARTE i 3 m 10 ft straight cord short strain relief USB Full Speed Cable Locking Plus Power Type A 5 m 17 ft straight cord short strain relief 54 54214x N 3 This cable is for use with full speed USB 40 interface only USB Low Speed Communication Cable Type A 2 8 m 9 2 ft straight cord short strain relief Communication Cable Host End Not Terminated 203 mm 8 straight cord short strain relief Flex Stand 3 46 00289 Flex Stand 6 Other items may be ordered for the specific protocol being used To order additional items contact the dealer distributor or call Metrologic s customer service department at 1 800 436 3876 INTRODUCTION Scanner Components Figure 1 Scanner Components DESCRIPTION Red Output Window Laser Aperture Pin Hole for Cable Release 10 Pin RJ45 Female Socket Speaker Blue and White LED Indicators E Prote
11. of MS3580 Stand Removed MS3580 47 Keyboard Wedge MS3580 41 and Stand Alone Keyboard RS232C and Light Pen Emulation Function i Function Ground Ground RS232 Transmit Output RS232 Transmit Output CTS Input Shield Ground SCANNER AND CABLE TERMINATIONS MS3580 11 IBM 468X 469X MS3580 9 OCIA Ground Ground RTS Output IBM B Transmit 7 Clock Out Clock in Return IBM At Receive Clock out Rtrn 5VDC 5VDC Shield Ground Shield Ground Ground DTR Input TTL RS232 Scan Enable Transmit TTL RS232 Scan Data 10 Shield Ground 41 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations Host End Standard PowerLink Cable MLPN 54 54000 x 3 straight Shield Ground RS232 Transmit Output RS232 Receive Input DTR Input Light Pen Source CTS Input 9 Pin D Tvpe Connector RTS Output 5VDC USB Power Communication Cable MLPN 54 54213 4 N 3 54 54214 4 N 3 or 54 54235 X N 3 4 USB Type A Locking with Power Stand Alone Keyboard PowerLink Cable MLPN 54 54020 31 3 PC Data No Connect 5VDC PC Power to KB PC Clock 6 Pin Male Mini DIN Connector No Connect 42 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations Host End Keyboard Wedge PowerLink Cable 54 54002 x 3 Function Keyboard Clock 8 i Keyboard Data Ri LZ 5 Pin DIN F
12. operate this device This device complies with part 15 ofthe FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice This Class A digital apparatus complies with Canadian ICES 003 Remarque Cet appareil num rique de la classe A conform a la norme NMB 003 du Canada European Standard Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Funkst reigenschaften nach EN 55022 1998 Warnung Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkst rungen verursachen in diesem fall kann vom Betrieber verlangt werden angemessene Ma nahmen durchf hren Standard Europeo Attenzione Questo e un prodotto di classe A Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all utilizzatore opportune misure Attention Ce produit est de classe A Dans un environnement domestique ce produit peut tre la cause d interf rences radio Dans ce cas l utiliseteur peut tre amen predre les mesures ad quates 45 LIMITED WARRANTY The MS3580 QuantumT scanners are manufactured by Metrologic at its Blackwood New Jersey U S A fa
13. speed i Check if it is a check digit character or border problem Check if check digits are set properly Check if the correct minimum symbol length is set TROUBLESHOOTING GUIDE Possible Cause s Symptoms All Interfaces During power up the unit beeps 3 times There is a non volatile i RAM failure During power up the unit razzes continuously There is a RAM or ROM failure During power up the unit razzes once and the blue LED flashes During power up the unit razzes twice and both LEDs flash There is a scanner motor failure RS232 Only l The com port at the host is not working or The unit powers is not configured up OK and properly scans OK but v does not 2 The cable is not connected to the proper com port communicate properly to the host B i The com port is not operating properly There is a VLD failure Solution Contact a Metrologic service representative Contact a Metrologic service representative Contact a Metrologic service representative Contact a Metrologic service representative e Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is looking for RS232 data 29 TROUBLESHOOTING GUIDE Symptoms RS232 Only The host is receiving data but the data does not look correct Poss
14. the scan field 17 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the unit s primary scan pattern has been set to all scan lines omnidirectional reading and the secondary pattern has been set to single line menu reading with a 5 second button click timeout configured The primary scan pattern is active when the scanner starts To activate the secondary scan pattern press and hold the button To scan and transmit the bar code align the laser line over the bar code while continuing to hold down the button The scanner will beep once to indicate the bar code has been scanned and transmitted The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field 18 SCANNER OPERATION Audible Indicators When the MS3580 is in operation it provides audible feedback to indicate the status ofthe scanner Eight settings are available for the tone of the beep normal 6 alternate tones and no tone For instructions on how to change the tone of the beeper refer to the MetroSelect Configuration Guide 00 02407 AS One Beep When the scanner first receives power the white LED will flash the blue LED will turn on and the scanner will beep once the white LED will remain on for the duration of the beep The scanner is now ready t
15. 0 1 48 63 78 78 Fax 33 0 1 48 63 24 94 Email info fr metrologic com Spain Madrid Metrologic Eria Ib rica SL Tel 34 913 272 400 Fax 34 913 273 829 Email info es metrologic com Metrologic European Repair Center MERC Metrologic Eria Ib rica SL Tel 34 913 751 249 Fax 34 913 270 437 United Kingdom Basingstoke Metrologic Instruments UK Limited Tel 44 0 1256 365900 Fax 44 0 1256 365955 Email info uk metrologic com Russia Moscow Metrologic Russia Tel 7 095 730 7424 Fax 7 095 730 7425 Email info ru metrologic com Poland Warsaw Metrologic Instruments Poland Sp z 0 0 Tel 48 22 545 04 30 Fax 48 22 545 04 31 Email info pl metrologic com June 2005 Printed in the USA 00 05090B
16. 30 39 B Bar Code 19 21 27 30 31 Bar Wd 31 Been 19 20 21 27 30 39 Blue LED 19 21 27 30 39 Button eene 4 13 18 C Cable Communication 2 8 12 27 30 39 42 43 Keyboard Wedge 42 43 Pin Assignments 42 43 PowerLink 2 5 8 12 39 42 43 Troubleshooting 27 30 USB desde deret ieri 42 43 Caution 5 8 12 44 AAA CETTE 45 CodeGate 1 13 18 Communication 20 27 30 33 Parameters 34 38 Compliance ee 8 12 Components cocccccccccococoncccncnnnnnnns 2 4 Configuration 19 21 Default reiii 34 38 CUI Nt iiu entree 32 Customer Service 46 50 D Dit la 2 32 Default Settings 13 14 33 34 38 Depth of Field Normal 22 24 31 38 Reduced 23 24 25 31 38 F Failure Modes PA AEAEE E 21 FOG oie need ob 45 Firmware nannte 39 Flash ROM 1 39 H Host cs iiie tuere 27 30 I EE 9 34 38 Indicator Audible 4 13 19 21 27 30 31 39 Failure oocoooococonoconcncnonononononnnn 21 Visual 4 19 21 27 30 31 39 Interface 31 IDN 1 9 34 38 Keyboard Wedge1 10 30 34 38 Laser Emulation 1 8 34 38 Light Pen 1 8 34 38 OGIA iive tn gege 1 9 34 38 RS232 1 8 29 30 34 38 RS232 TTL
17. SHANGHAI CO LTD Suzhou Sales Office BLK A Room 03 03 04 No 5 Xinghan Street Xinsu Industrial Square China Singapore Suahou Industrial Park Suzhou PRC Tel 86 512 67622550 Fax 86 512 67622560 Email info cn metrologic com 46 PATENTS Patent Information This METROLOGIC product may be covered by one or more of the following U S Patents U S Patent No 5 216 232 5 260 553 5 340 971 5 424 525 5 484 992 5 525 789 5 528 024 5 557 093 5 616 908 5 627 359 5 637 852 5 661 292 5 777 315 5 789 730 5 789 731 5 811 780 5 828 048 5 844 227 5 925 870 6 029 894 6 098 885 6 209 789 6 257 492 6 286 760 6 299 067 6 347 743 6 412 696 6 460 767 No license right or sublicense is granted either expressly or by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are licensed to METROLOGIC including any third party patent listed above except for an implied license only for the normal intended use of the specific equipment circuits and devices represented by or contained in the METROLOGIC products that are physically transferred to the user and only to the extent of METROLOGIC S license rights and subject to any conditions covenants and restrictions therein Other worldwide patents pending 47 A EE 2 8 12 ACCESSOTIES nnii 2 3 Adapter ties 10 Audible Indicator 13 19 21 27
18. ail info br metrologic com Outside Brazil S o Paulo Metrologic South America Tel 55 11 5182 7273 Fax 55 11 5182 7198 Email info sa metrologic com ASIAN HEADQUARTERS Asia Singapore Metrologic Asia Pte Ltd Tel 65 6842 7155 Fax 65 6842 7166 Email info sg metrologic com China MTLG Auto ID Instruments Shanghai Co Ltd Tel 86 2158692780 Fax 86 21 58692782 Email info cn metrologic com Metro Suzhou Sales Office Tel 86 512 67622550 Fax 86 512 67622560 Email info cn metrologic com Guangzhou Sales Office Tel 86 20 38823476 Fax 86 20 38823477 Email info cn metrologic com Beijing Sales Office Tel Fax 86 10 82253472 Email info cn metrologic com Japan Tokyo Metrologic Japan Co Ltd Tel 81 03 3839 8511 Fax 81 03 3839 8519 Email info jp metrologic com India Bangalore Metrologic India Tel 91 80 51256718 Fax 91 80 51256719 Email info in metrologic com 50 EUROPEAN MIDDLE EAST amp AFRICAN HEADQUARTERS Germany Munich Metrologic Instruments GmbH Tel 49 89 89019 0 Fax 49 89 89019 200 Email info europe metrologic com Germany Austria and Switzerland Tel 49 89 89019 0 Fax 49 89 89019 200 Email info de metrologic com Eastern Europe and Middle East Tel 49 89 89019 222 Fax 49 89 89019 173 Italy Bologna Metrologic Instruments Italia srl Tel 39 0 51 6511978 Fax 39 0 51 6521337 Email info it metrologic com France Paris Metrologic Eria France SA Tel 33
19. an Pattern User Replaceable Single Cable Interface to Host PowerLink Compatible Decoding of All Standard 1D RSS 14 RSS Limited and Expanded RSS Bar Codes 7 Beeper Tones Configurable Depth of Field Flash Upgradeable Firmware OPOS and JPOS System Compatible CodeGate Sunrise 2005 Compliant QUANTUMT INTERFACE MS3580 9 OCIA and RS232 Transmit Receive IBM 46xx and Full RS232 i RS232 Low Speed USB i Keyboard Emulation Mode or Serial Emulation Mode Full Speed USB RS232 Light Pen Emulation Keyboard Wedge Stand Alone Keyboard and RS232 Transmit Receive MS3580 104 RS232 TTL Laser Emulation Configurable for Keyboard Emulation Mode or Serial Emulation Mode Default setting is Keyboard Emulation Mode INTRODUCTION Scanner and Accessories Bas c KIT COMPONENTS Part No Description MS3580 QuantumT Omni Single Line Scanner Quantum Omni Single Line Scanner Installation and User s Guide 00 02407 MetroSelect Configuration Guide Guides also available for download at www metrologic com OPTIONAL ACCESSORIES Part No Description 45 45593 120V United States and Canada Ls EE n Uer ENER n T p c un 220V 240V China 46 46983 RS232 PowerLink Cable with Built in Power Jack 54 54000x 3 21m 7 ft straight cord short strain relief Metrologic Voltage Converter Cable 12VDC to 5 2VDC Contact a Metrologic
20. aults to a minimum of 4 character bar i code 27 TROUBLESHOOTING GUIDE Symptoms All Interfaces The unit scans a bar code but locks up after the first scan the white LED stays on The unit scans but the data transmitted to the host is incorrect Scanner beeps at some bar codes and NOT same bar code symbology 28 Possible Cause s The scanner is configured to support some form of host handshaking but is not E supporting the handshaking i properly receiving the signal i The scanner s data format does not match the host system requirements The print quality of the bar code is suspect The aspect ratio of the bar code is out of _ tolerance The bar code may have been printed for others of the incorrectly i The scanner is not i configured correctly for the type of bar i code The minimum symbol length setting does not work with the bar code Solution If the scanner is setup to support i ACK NAK RTS CTS XON XOFF or DIE verify that the host cable and host are Verify that the scanner s data format matches the format required by the host i Make sure that the scanner is connected to the proper host i port The type of printer and or the printer settings could be the problem Check the print mode or change _ the printer settings For example change to econo mode or high
21. blasts off to new software upgrades Each MS3580 regardless of the version number or communication protocol can be upgraded All RS232 41 keyboard wedge 47 light pen 41 OCIA 9 IBM 468X 469X 11 low speed USB 38 integrated full speed USB 40 and RS232 TTL Laser Emulation 104 units can be upgraded To upgrade all units a power supply and a PowerLink cable MLPN 54 54014 are required RS232 units can be upgraded using the standard PowerLink cable MLPN 54 54000 x 3 The program guides the user with its simplistic one click approach The user must first select the file Once the file is selected and verified the scanner is ready to be upgraded Press the Flash Scanner button to upgrade the scanner The unit will go into a flash mode both the blue and white LEDs will be on The user can follow the progress of the upgrade by watching the screen for details When the upgrade is complete the scanner will respond with its normal one beep on power up If two beeps occur the scanner did not upgrade properly Contact a Metrologic service representative for additional assistance 39 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS3580 scanner interfaces terminate to a 10 pin modular socket The serial label indicates the interface enabled when the scanner is shipped from the factory 10 pin RJ45 Female Socket Pin 10 Pin 1 Figure 20 Bottom View
22. can Pattern 1 31 Horizontal Raster 13 Omnidirectional 13 18 Primary se 13 18 Secondary 13 18 Single Line 13 18 Scan Speed cncccccococoncconancninnnnnnnns 31 SELV Hr rto nein tee 8 12 Single Line eee 13 18 Specification Electrical 2 52 Rm 32 Environmental 32 Mechanical 32 Operational 31 Stand Alone Keyboard 11 Otorage EE 32 Sweet Spot Mode 38 T TONG cca SE has 19 TONGS TED RETE 1 Transformer cooccccnncncnncnoconnnnnnnns 2 32 Troubleshooting 27 30 U Upgrade eines 39 USB 12 34 38 V Ventilation esses 32 Visual Indicator 19 21 27 30 39 Blue LED 4 19 21 27 30 White LED 4 19 21 27 30 Yellow LED 4 19 21 27 30 Voltage 8 12 32 Molume rientra 19 W Warranty sssssssesee 46 Ce crees 31 White LED 19 21 27 30 39 Window eee 4 49 CONTACT INFORMATION AND OFFICE LOCATIONS CORPORATE HEADQUARTERS NORTH AMERICA USA New Jersey Metrologic Instruments Inc Tel 1 800 ID METRO Fax 856 228 6673 Email info metrologic com SOUTH AMERICA AND CENTRAL AMERICA Brazil S o Paulo Metrologic do Brasil Ltda Tel 55 11 5182 8226 Fax 55 11 5182 8315 Em
23. cility The MS3580 QuantumT scanners have a three 3 year limited warranty from the date of manufacture Metrologic warrants and represents that all MS3580 QuantumT scanners are free of all defects in material workmanship and design and have been produced and labeled in compliance with all applicable U S Federal state and local laws regulations and ordinances pertaining to their production and labeling This warranty is limited to repair replacement of product or refund of product price at the sole discretion of Metrologic Faulty equipment must be returned to one of the following Metrologic repair facilities Blackwood New Jersey USA Madrid Spain or Suzhou China To do this contact the appropriate Metrologic Customer Service Repair Department to obtain a Returned Material Authorization RMA number In the event that it is determined the equipment failure is covered under this warranty Metrologic shall at its sole option repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight whether distributor dealer reseller or retail consumer or refund an amount equal to the original purchase price This limited warranty does not extend to any Product which in the sole judgment of Metrologic has been subjected to abuse misuse neglect improper installation or accident nor any damage due to use or misuse produced from integrat
24. ctive Boot and Stand Connection Never remove the protective boot from the MS3580 7 l Removing the protective boot will expose electrical d components of the scanner that are highly susceptible to electrostatic discharge ESD Pedestal Stand 8 The type of stand provided is dependent on the specific d MS3540 kit purchased INTRODUCTION Caution and Serial Number Labels Cable Removal Figure 3 Maintenance 1002 9z Ainr pajep 05 ON SION Jese7 0 juensund suoneinep 104 Kleng LL OtOL OL OPO SUBA H49 LZ up seiduio onpoud siut ce i Ws Complies with FCC and ICES 003 Class A See manual See User s guide for patent coverage Manufactured Blackwood NJ June 2005 A 41 Model MS3580 RS232 LTPN Blackwood New Jersey U S A 5V QuantumT By Metrologic Instruments Inc Barcode Scanner CAUTION CLASS 2 LASER LIGHT WHEN OPEN DO NOT STARE INTO THE BEAM ATTENTION RAYONN EMENT LASER CLASSE 2 LORS DE L OUVERTURE NE PAS REGARDER FIXEMENT DANS LE FAISCEAU ABI E STRAHL BLICKEN CUIDADO LUZ LASER CLASE 2 AL ABRIR NO FIJAR LA VISTA EN EL RAYO Warranty VOID if case opened Contains no user serviceable components Figure 2 Locate the small pin hole on the side of the QuantumT near the cable Bend an ordinary paperclip into the shape shown Insert the paperclip or other small metallic pin into the small pin hole You will hear
25. ds all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 To maintain compliance with standard CSA C22 2 No 60950 UL 60950 and norm EN IEC 60950 the power source should meet applicable performance requirements for a limited power source 11 INSTALLATION Full Speed or Low Speed USB 1 2 12 Turn off the host device Plug the male 10 pin RJ45 end of the USB cable into the 10 pin socket on the MS3580 Plug the other end of the USB interface cable into the host device s USB port Turn on the host device Figure 12 El When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED H As a default the MS3580 38 leaves the factory with USB Keyboard Emulation Mode enabled For information on configuring the MS3580 38 for USB Serial Emulation Mode please refer to Section P Low Speed USB in the MetroSelect Configuration Guide MLPN 00 02407 i Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication to occur Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low
26. e L utilizzo di sistemi di controllo di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale pu provocare delle esposizioni a raggi laser rischiose Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser Non guardate mai il raggio laser anche se credete che lo scanner non sia attivo Non aprite mai lo scanner per guardare dentro l apparecchio Facendolo potete esporVi ad una esposizione laser rischiosa L uso di apparecchi ottici equipaggiati con raggi laser aumenta il rischio di danni alla vista CLASS 1 LASER PRODUCT APPAREIL A LASER DE CLASSE 1 LASER KLASSE 1 PRODUKT LASER CLASE 1 PRODUCTO 44 LASER AND PRODUCT SAFETY Notices This equipment has been tested and found to comply with limits for a Class A digital device pursuant to part 15 ofthe FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Any unauthorized changes or modifications to this equipment could void the user s authority to
27. e interface supports a parameter listed in the charts on the following pages a check mark v will appear RS232 OR LIGHT IBM LASER PARAMETER DEFAULT OCIA USB RS232 PEN 46XX KBW EXULON lt UPC EAN ES MSI Plessey 10 10 Check Digit MSI Plessey MOD 10 Check Digit RSS14 Check Digit RSS Expanded Enable 34 DEFAULT SETTINGS COMMUNICATION PARAMETERS RS232 OR LIGHT IBM LASER PARAMETER DEFAULT OCIA USB RS232 PEN 46XX KBW EXAMEN TIL Expanded ID Je0 SS Beeper Tone Beep Transmit Sequence Same Symbol Rescan Timeout 500 msecs Programmable in 50 msec steps MAX 6 35 seconds Intercharacter Delay Programmable in 1 msec steps MAX 255 msecs Number of Scan Buffers 35 DEFAULT SETTINGS COMMUNICATION PARAMETERS RS232 OR LIGHT IBM LASER PARAMETER DEFAULT OCIA USB RS232 PEN 46XX KBW EMULATION Transmit UPC A Check Digit Transmit UPC E Check Digit Transmit UPC A Number System Transmit UPC A Manufacturer ID Transmit Codabar Start Stop Characters Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop Start Characters Transmit MSI Plessey Check Characters Transmit Sanyo ID Characters 36 DEFAULT SETTINGS COMMUNICATION PARAMETERS RS232 OR LIGHT IBM
28. ed a motor failure Return the unit to an authorized service center for repair Continuous Razzberry Tone with Both LEDs Off If upon power up the scanner emits a continuous razzberry tone then the scanner has an electronic failure Return the unit to an authorized service center for repair Three Beeps On Power Up If the scanner beeps 3 times on power up then the nonvolatile memory that holds the scanner configuration has failed Return the unit to an authorized service center for repair 21 SCANNER OPERATION Depth of Field Specifications Normal Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Scan Zone Scan Zone Figure 14 MS3580 Normal Depth of Field All specifications are subject to change without notice MS3580 shown with pedestal stand 22 150 SCANNER OPERATION Depth of Field Specifications Reduced Scan Zone Specifications are based on a 0 33 mm 13 mil bar code 7 100 mm 4 er 35 mm 1 4 146 mm E 100 mm 4 35 mm E 1 4 Figure 15 MS3580 Reduced Depth of Field All specifications are subject to change without notice t MS3580 shown with pedestal stand 23 SCANNER OPERATION Depth of Field by Bar Code Element Width Normal Scan Zone b P a z LO LO N ie z LOU Q Q o io io e 44 y y n GE Y st N o EOM Po rA DE eo
29. emale 5 Volts DC Function PC Data 6 Pin DIN Male 5 Volts DC ar No Connect Metrologic will supply an adapter cable with a 5 pin DIN male connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC Keyboard Wedge Adapter Cable No Connect 5 Volts DC Function Keyboard Data No Connect Power Ground 6 pin Mini DIN Female No Connect 43 LASER AND PRODUCT SAFETY IN Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure Under no circumstances should the customer attempt to service the laser scanner Never attempt to look at the laser beam even ifthe scanner appears to be nonfunctional Never open the scanner in an attempt to look into the device Doing so could result in hazardous laser light exposure The use of optical instruments with the laser equipment will increase eye hazard IN Atenci n La modificaci n de los procedimientos o la utilizaci n de controles o ajustes distintos de los especificados aqui pueden provocar una luz de l ser peligrosa Bajo ninguna circunstancia el usuario deber realizar el mantenimiento del l
30. en Emulation Keyboard Wedge Stand Alone Keyboard and RS232 Transmit Receive RS232 Transistor Transistor Logic TTL Laser Emulation The MS3580 scanner with built in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only Many RS232 programmable functions e g formatting available in other Metrologic scanners are also available as keyboard wedge functions The following are the most important selectable options specific to the keyboard wedge Keyboard Type e AT includes IBM PS2 models 50 55 60 80 e XT e IBM PS2 includes models 30 70 8556 Keyboard Country Type e USA e German e Spanish e Belgium e Italian e Swiss e French e Japan e United Kingdom Default setting For a complete list of default settings see Default Settings Communication Parameters starting on page 34 of this guide Refer to the MetroSelect Configuration Guide MLPN 00 02407 or MetroSet2 s help files for information on how to change the default settings 33 DEFAULT SETTINGS COMMUNICATION PARAMETERS Many functions of the scanner can be configured that is enabled or disabled The scanner is shipped from the factory configured to a set of default conditions The default parameter of the scanner has an asterisk in the charts on the following pages If an asterisk is not in the default column then the default setting is Off or Disabled Every interface does not support every parameter Ifth
31. ents for a limited power source INSTALLATION Keyboard Wedge 1 Turn off the host device 2 Plug the male 10 pin RJ45 end of the PowerLink cable into the 10 pin socket on the MS3580 3 Disconnect the keyboard from the host device 4 Connectthe Y end of the PowerLink cable to the keyboard and the keyboard port on the host PC If necessary use the male female adapter cable supplied with the scanner for proper connections 5 Plug the external power supply into the power jack on the PowerLink cable Check the AC input requirements nom of the power supply to make sure Adapter the voltage matches the AC outlet The outlet must be located near the equipment and be easily accessible Figure 10 6 Connect AC power to the transformer Turn on the host device E When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED Powering the MS3580 directly from the host device can sometimes cause interference with the operation of the scanner or the computer Not all computers supply the same current through the keyboard port For this reason Metrologic recommends using an external power supply For additional information contact a Metrologic customer service representative Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirement
32. he Laser Emulation Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC A 60950 To maintain compliance with standard CSA C22 2 No 60950 UL 60950 and norm EN IEC 60950 the power source should meet applicable performance requirements for a limited power source INSTALLATION IBM 46xx or OCIA 1 Turn off the host device 2 Plug the male 10 pin RJ45 end of the MVC cable into the 10 pin socket on the MS3580 3 Connectthe other end of the MVC SNE cable to the host device CR MVC Cable 4 Turn on the host device on Host end connection is application dependent Figure 9 When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication to occur Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC A 60950 To maintain compliance with standard CSA C22 2 No 60950 UL 60950 and norm EN IEC 60950 the power source should meet applicable performance requirem
33. ible Cause s The scanner and host may not be configured for the same interface i The intercharacter Characters are being dropped delay needs to be added to the transmitted output Keyboard Wedge Only The unit scans the bar code but there is no The unit scans but the data is not correct The unit is not transmitting each character Alpha characters show as lower Everything works except for a couple of characters 30 l The unit may not be configured correctly The unit may not be E configured correctly The unit may not be configured correctly The computer is in i caps lock mode i These characters may i not be supported by the current country s key look up table Solution Check that the scanner and the host are configured for the same i interface Add some intercharacter delay to the transmitted output by using i the MetroSelect Configuration i Guide MLPN 00 02407 Make sure the scanner is configured for the appropriate i mode i Make sure that the proper PC type ie AT PS2 or XT is selected Verify correct country code and data formatting are selected Adjust the intercharacter delay i Increase the interscan code delay setting Adjust whether the FO break is transmitted It may be necessary to try both i settings Enable caps lock detect setting e of the scanner to detect whether the PC is
34. ion of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened by anyone other than Metrologic s repair department or authorized repair centers THIS LIMITED WARRANTY EXCEPT AS TO TITLE IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES EITHER EXPRESS OR IMPLIED AND SPECIFICALLY EXCLUDES WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE OR ARISING OUT OF CUSTOM OR CONDUCT THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES TO PERSON OR PROPERTY OR EFFECT ON BUSINESS OR PROPERTY OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT EXCEPT AS STATED IN THIS WARRANTY IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN CORPORATE HEADQUARTERS METROLOGIC EUROPEAN REPAIR CENTER NORTH AMERICA MERC Metrologic Instruments Inc Metrologic Eria Ib rica SL 90 Coles Rd C Alfonso Gomez 38 40 1D Blackwood NJ 08012 4683 28037 Madrid Customer Service Department Tel 34 913 751 249 Tel 1 800 ID METRO Fax 34 913 270 437 Fax 856 228 6673 Email info metrologic com MTLG Auro ID INSTRUMENTS
35. o scan When the scanner successfully reads a bar code the white LED will flash and the scanner will emit a beep if configured to do so If the scanner does not beep once and the white light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to Failure Mode Indicators on page 21 MESIT Three Beeps during operation When placing the scanner in configuration mode the white LED will flash while the scanner simultaneously beeps three times The white and blue LEDs will continue to flash until the unit exits configuration mode Upon exiting configuration mode the scanner will beep three times and the white LED will stop flashing When configured 3 beeps can also indicate a communications timeout during normal scanning mode When using one code programming the scanner will beep three times the current selected tone followed by a short pause a high tone and a low tone This tells the user that the single configuration bar code has successfully configured the scanner MEDIT Three Beeps on power up This is a failure indicator Refer to Failure Mode Indicators on page 21 19 SCANNER OPERATION Visual Indicators The Quantum is equipped with a blue and white LED that indicates the scanner s state and the status of the current scan when the unit is in operation Figure 13 Speaker Location and LED Location No LEDs The LEDs will not be illumina
36. operating in caps lock Try operating the scanner in Alt Mode DESIGN SPECIFICATIONS MS3580 Operational Visible Laser Diode VLD 650 nm 0 33 mm 13 mil bar code 0 127 mm 5 0 mil 1 All standard 1 D bar codes including RSS 14 RSS Expanded and RSS 14 Limited RS232 Keyboard Wedge Stand Alone Keyboard Light Pen Emulation IBM468x 469x USB low speed and full speed Laser Emulation RS232 TTL OCIA 3596 minimum reflectance difference Up to 80 data characters i Maximum number will vary based on symbology and density 7 tones or no beep Blue laser on ready to scan White good read decoding Specifications subject to change without notice 31 DESIGN SPECIFICATIONS MS3580 Mechanical 230 mA typical at 5VDC IEC 60825 1 1993 A1 1997 A2 2001 EN 60825 1 1994 A11 1996 A2 2001 FCC ICES 003 amp EN 55022 Class A 20 C to 40 C 4 F to 104 F 40 C to 60 C 40 F to 140 F 5 to 95 relative humidity non condensing Sealed to resist airborne particulate contaminants None required Specifications subject to change without notice 32 APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol VERSION SCANNER COMMUNICATION PROTOCOL S IDENTIFIER CIA and RS232 Transmit Receive ow Spee i Keyboard Emulation or Serial Emulation MS3580 Full RS232C Light P
37. r 1 800 436 3876 to preserve the limited warranty terms on page 46 Symptoms Possible Cause s Solution All Interfaces The unit has no LEDs beeper or motor spin The unit has no LEDs and or beeper There are multiple scans upon presentation of The unit powers up but does not The unit powers up but does not scan and or beep No power is being supplied to the scanner No power is being supplied to the scanner from host The same symbol timeout is set too The beeper is disabled No tone is selected The unit is trying to scan a particular symbology that is not enabled The scanner has been programmed for a character length lock or a minimum length and bar code being scanned does not i satisfy the i programmed criteria Check the transformer outlet i and power strip Make sure the cable is plugged into the scanner Some host systems cannot supply enough current to power the MS3580 Use the power supply included with the Scanner Adjust the same symbol timeout for a longer time increment Enable the beeper Select a tone UPC EAN Code 39 Interleaved 2 of 5 Code 93 Code 128 and Codabar are enabled by default i Verify that the type of bar code i being read has been selected Verify that the bar code that is i being scanned falls into the criteria Typical of Non UPC EAN codes The scanner def
38. s The button on the side of the MS3580 can be configured to function in one of four modes e Button Click Mode with CodeGate Enabled Default e Button Click Mode with CodeGate Disabled e Button Hold Mode with CodeGate Enabled e Button Hold Mode with CodeGate Disabled The following pages include examples of how the button will function when the unit has been configured to operate in each of the four button modes 13 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the unit s primary scan pattern has been set to all scan lines omnidirectional reading and the secondary pattern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and release the button 3 To decode and transmit the bar code press and release the button The scanner will beep once 4 To reactivate the primary scan pattern double click the button or after 5 seconds of no scanning the unit will automatically reactivate the primary pattern 14 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the unit s primary scan pattern has been set to all scan lines omnidirectional reading and
39. s for SELV Safety Extra Low Voltage according to EN IEC A 60950 To maintain compliance with standard CSA C22 2 No 60950 UL 60950 and norm EN IEC 60950 the power source should meet applicable performance requirements for a limited power source 10 INSTALLATION Stand Alone Keyboard 1 2 5 Turn off the host device Plug the male 10 pin RJ45 end of the PowerLink cable into the 10 pin socket on the MS3580 Connect the other end of the PowerLink cable to the keyboard port on the host device Plug the external power supply into the power jack on the PowerLink cable Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet The outlet must be located near the equipment and be easily accessible Connect AC power to the transformer Figure 11 6 Turn on the host device When the scanner first receives power the blue LED will turn on the scanner will simultaneously emit a beep and flash the white LED Powering the MS3580 directly from the host device can sometimes cause interference with the operation of the scanner or the computer Not all computers supply the same current through the keyboard port For this reason Metrologic recommends using an external power supply For additional information contact a Metrologic customer service representative Caution To maintain compliance with applicable standar
40. ted if the scanner is not receiving power from the host or transformer They are also not illuminated when the laser is turned off for any reason Steady Blue When the laser is active the blue LED is illuminated The blue LED will remain illuminated until the laser is deactivated Steady Blue and Single White Flash When the scanner successfully reads a bar code the white LED will flash and the scanner will beep once If the white LED does not flash or the scanner does not beep once then the bar code has not been successfully read Steady White and Blue After a successful scan the scanner transmits the data to the host device Some communication modes require that the host inform the scanner when data is ready to be received If the host is not ready to accept the information the scanner s white LED will remain on until the data can be transmitted Alternating Blue and White Flashes This indicates the scanner is in program mode A razzberry tone indicates that an invalid bar code has been scanned in this mode Steady White Blue Off This indicates the scanner may be waiting for communication from the host 20 SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure Return the unit to an authorized service center for repair Flashing Blue and White and Two Razzberry Tones This indicates that the scanner has experienc
41. the secondary pattern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and release the button 3 The unit will beep once as it decodes and transmits the bar code 4 Toreactivate the primary scan pattern double click the button or after 5 seconds of no scanning the unit will automatically reactivate the primary pattern 15 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the unit s primary scan pattern has been set to all scan lines omnidirectional reading and the secondary pattern has been set to single line menu reading with a 5 second button click timeout configured 1 The primary scan pattern is active when the scanner starts 2 To activate the secondary scan pattern press and hold the button 3 To scan the bar code align the laser line over the bar code while continuing to hold down the button 4 Totransmit the bar code release the button The scanner will beep once 16 SCANNER OPERATION Configurable Button Functions 5 To scan and transmit additional bar codes repeat steps 2 through 4 6 The primary scan pattern will automatically reactivate after the button is released and no bar code is present in