Powerware P93 User's Manual

image

Contents

1. 7 kW 10 5 kW 14 kW 6 8 kW 4 9 kW 8 3 kW 3 2 kW 6 4 kW 9 6 kW 6 5 kW 3 2 kW 10 5 kW 6 4 kW 13 8 kW Internal battery 45 26 17 48 79 31 110 50 27 49 110 26 50 17 1 External battery cabinet 90 65 48 98 150 75 240 110 70 108 240 65 110 48 2 External battery cabinets 155 90 75 166 240 130 400 180 96 172 400 90 180 75 Contact Powerware for runtime application or configuration assistance A DC rated circuit breaker in each battery cabinet allows multiple battery strings to be serviced independently of each other assuring back up power is always available to the UPS Removable battery slide out tray assembles provide front access only and reduce battery maintenance time Manufacturer supplied wiring with quick disconnects provides plug and play capability for line up and match configurations Quick disconnects between battery tray assemblies reduce battery maintenance time Battery cabinets may be daisy chained together for extended battery runtimes up to 2 Integral configuration which line up and match is standard 1 Front access only enhances servicing and installation Slide trays and modular battery packaging makes periodic servicing easy Cabinets are UL 1778 listed Flame retardant batteries meet UL 94V2 for computer room installations Wiring installation 2 Powerware offers a full line of battery cabinets for the Powerware P93 Extended Battery Cabinets 1
2. Battery cabinets can be configured as line up and match or remotely located Customer must provide wiring for remotely located cabinets 2 If concurrent to P93 Field Installation Powerware PN 103003671 IBM PN 97P3604 Calculating runtime a guide Typical runtime is 15 minutes Formula runtime in minutes business 2 x system shutdown safety Business _____ Shutdown ____ x 2 _____ Safety _____ Total _____ Powerware IBM IBM Per P93 Part Number Feature Code Part Number Minimum Maximum External Battery Cabinet A13031 6635 97P2663 0 2 Additional options Input output galvanic isolation Voltage matching transformers Remote status panel Remote EPO button Contact Powerware Revised 01 04 Reprint 01 04 WORLDWIDE HEADQUARTERS 8609 Six Forks Road Raleigh NC 27615 U S A Toll Free 1 800 925 4426 www oem powerware com ibm ups CANADA Ontario 416 798 0112 EUROPE MIDDLE EAST AFRICA Denmark 45 3677 7910 Finland 358 9 452 661 France 33 1 60 12 74 00 Germany 49 7841 6660 Italy 39 02 66 04 05 40 Norway 47 23 03 65 50 Sweden 46 8 598 940 00 United Kingdom 44 1753 608 700 ASIA PACIFIC Australia NZ 612 9878 5000 China 86 21 6350 0606 HK Korea Taiwan 852 2745 6682 India 91 11 2649 9414 to 18 Singapore SEA 65 6829 8888 LATIN AMERICA Argentina 5411 4343 6323 Brazil 55 11 3616 8500 M xico 5255 9171 7777 Powerware Powerware P93 Specifications Options ProActive X
3. Features P93 features UPS is pre architected tested and optimized for eServer and storage applications Pre installation site evaluation Includes UPS installation and start up service Output distribution with breakers cables and receptacles ProActive 1 year service plan Exclusive 5 year onsite warranty offered through IBM with IBMSERV coordination UPS benefits Maximum availability with true double conversion online design the proven technology that is used for the most mission critical applications in the world Maximum efficiency the Powerware P93 s advanced design features efficiency of up to 93 the highest for a double conver sion online UPS in its kVA range Maximum performance the Powerware P93 delivers the high est performance by using digital signal processing true pulse width modulation and maximum IGBT responsiveness This provides easy setup drift free operation and a pristine output When purchased with Powerware Field Installation PN 103003671 IBM PN 97P3604 Powerware P93 9330 20 UPS Designed specifically to meet the high availability needs of critical 24x7 applications for small to medium size business the Powerware P93 delivers enhanced system reliability and the highest efficiency ratings of any online UPS in the 20 kVA range The P93 also contains high end features and benefits that only existed in larger capacity UPS until now The advanced features of the Power
4. PS cards are installed onsite and concurrently with P93 startup by Powerware Service Technician Customer responsible for software installation Output connections Three 3 NEMA non or locking receptacles outlets with breakers and connectors Each connector shall be on a cord with maximum length of 50 feet Choose from pSeries pSeries zSeries Feature Code IBM Plug Type iSeries Feature Code Part Number Feature Code Part Number 5 15R duplex 4 1412 1413 2960 9082 86G7648 9800 31L7061 2 4 5 20R duplex L5 15R 7 2960 9083 9082 31L7067 8 L5 20R L5 30R 6 15R 5 1410 1403 1411 1451 1452 1457 2961 amp 9082 183576 4 3 9909 9833 L6 15R 10 1414 1416 1453 1454 1458 186G7878 9 31L7070 1 6 20R 29 1400 1401 1423 L6 20R 11 1404 1406 1428 L6 30R 12 1424 1426 11F0113 4 Powerware IBM IBM Per P93 Part Number Feature Code Part Number Minimum Maximum Output power cords NEMA 103003673 9881 97P2660 0 6 Hardware installed onsite and concurrent to P93 installation Battery runtimes in minutes iSeries pSeries Storage Cluster 870 890 655 670 690 2105 1350 1600 with CEC CEC CEC 1 2 3 expansion I O I O I O node nodes nodes up to 8 way 32 way standard enclosure 10 kVA 15 kVA 20 kVA 16 way 16 way 32 way 1 I O 2 I O 3 I O 32 way 1 I O 3 I O
5. Slot X Slot X Slot P93 Cabinet EBC Service Web SNMP Multi Server Relay Output power cords IBM feature code 6635 7001 7002 2934 2933 2936 9880 9881 IBM part number 97P2653 97P2654 97P2663 97P2657 97P2658 53P4619 04N7027 97P3886 97P2659 97P2660 Input Voltage Volts 208 Output voltage Volts 208 Input output frequency Hz 50 60 Input voltage range Minimum Volts 177 Maximum Volts 228 Rectifier input Amps 52 Bypass input Nominal amps Amps 55 5 AC output Nominal Amps 55 5 10 minutes Amps 69 4 Battery Nominal voltage Volts 288 288 Max charge voltage 25 C Volts 340 340 Charge current Amps 7 Nominal discharge current Amps 52 Total cell count 144 144 System efficiency 100 load 92 4 75 load 92 7 50 load 92 9 Maximum heat dissipation BTU hr x1000 3 9 kcal hr 990 Inverter efficiency full load 94 Physical attributes max Width in cm 22 56 17 52 17 52 50 ft maximum cord Height in c
6. connectivity Through its easy to use graphical user interface PowerVision provides critical information about the power network wide in real time FORESEER FORESEER environmental monitoring software puts an end to worries about risks to your critical foundation equipment and systems From air conditioners to water cooling systems generators to UPS FORESEER gives you up to the minute information about any system or device that is fundamental to your system availability Plus with its unique data archiving capabilities FORESEER can identify potential problems before they occur and notify you so you can implement a solution before a crisis ConnectUPS Adapters Powerware s ConnectUPS X and communications adapters provide a self contained link between the UPS and the Ethernet LAN WAN Using HTTP Telnet or SNMP you can easily monitor manage and shut down or reboot remote UPS protected servers routers hubs and other key network devices in a controlled manner These adapters are also compatible with many third party network management software packages Intelligent Communications P93 Options ProActive service additional year s plan description 7x24 corrective maintenance coverage 7x24 annual performance check Annual power protection audit 7x24 remote monitoring advance response Monthly UPS performance report with web access to account information and site service activity Powerware IBM IBM Per P93 Part Number Feat
7. critical decisions from scheduling preventive maintenance to load shedding Advances in firmware digital technology and battery monitoring techniques enable the Powerware P93 to offer sophisticated battery management features previously available only in expensive add on systems By ensuring optimal battery health and availability DC Expert Plus raises the reliability of the Powerware P93 far beyond any other UPS in this kVA range DC Expert Plus advanced features include Powerware Battery Lifetime Monitor uses measures of chronological time number of battery discharges battery temperature and system loading to determine battery lifetime remaining Battery Runtime Remaining Monitor uses system loading plus internal sensing points for voltage and current data to calculate runtime remaining Advanced Battery Management ABM uses patented three stage charging technique that not only increases battery service life but also optimizes recharge time Battery Circuit Test BCT performs a periodic test of the battery string to ensure that there are no open circuits that would jeopardize battery performance and system availability Temperature Compensated Charging TCC monitors the battery temperature and through sophisticated algorithms adjusts the rate of charge compensating for the ambient temperature to prolong the life of the battery Intelligent Battery Protection IBP automatically adjusts the shutdown voltage of the batteries based
8. es in conjunction with LanSafe software included with UPS The advanced features of the MultiServer card include Real time monitoring of critical power parameters Graceful unattended shutdown of multiple computers Maximizes uptime of more critical loads through operation in tandem with load segment feature of UPS Supports simple signaling relay contacts through additional DB 9 port Relay Interface Card The Powerware Relay Interface card is an X Slot connectivity device that provides monitoring of UPS status through isolated dry contact Form C relays It also provides the interface for AS 400 computers as well as many industrial applications The advanced features of the Relay Interface card include Isolated dry contact Form C relays for utility failure low battery UPS alarm OK or on bypass User selectable normally open or normally closed contacts Remote shutdown of UPS through integrated shutdown function Hot swappable UPS maintains power to critical applications while changing cards Powerware IBM IBM Per P93 Part Number Feature Code Part Number Minimum Maximum ConnectUPS X Slot Web SNMP card 103002974 5501 2934 53P4619 0 2 ConnectUPS X Slot MultiServer card 05146447 3901 2933 04N7027 0 2 ConnectUPS Relay Interface card amp cable 103003564 2936 97P3886 0 2 Maximum combination of FC 2933 2934 2936 and other ConnectUPS X Slot card options is two ConnectU
9. m 45 114 45 114 45 114 Depth in cm 31 79 38 97 31 79 Weight installed lb kg 958 435 200 90 600 272 5 2 5 5 2 20 lb each connector 6 4 6 Point loading lb kg 160 73 50 230 145 100 N A N A N A N A N A Min max qty per P93 1 1 0 2 0 4 0 4 0 2 0 2 0 2 1 1 0 6 Quantity 2 60 A 3 phase 4 wire IEC 309 460R9W with breakers and connec tors Quantity 3 See FC 9881 description
10. n Fans easily replaced while online Easy installation Casters provide for easy placement of unit Multiple wire entry locations Simple installation of communication option cards Terminal blocks for input output wiring Front covers designed with magnetic latches for effortless removal and replacement Exceptional design for service Front and top access for service Dedicated service port prevents any disturbance to the customer s communication setup Battery circuit breaker Internal maintenance bypass switch provides isolation for safe servicing Input circuit breaker Slide out battery trays with quick disconnects Bundled communications package iSeries interface port and cable 25 ft Modem for 7x24 remote monitoring and Advance Response Service1 RS 232 port DB 9 4 Building alarm inputs 2 Summary contacts 2 Unused communication slots supports up to two different communications options Other standard features include UL 1778 cUL CAN CSA C22 2 No 107 1 Exceeds IEC 62040 3 UPS definition Double conversion online technology Cold start capability from battery Wide input voltage and frequency window Dual source input to rectifier and bypass Quiet operation less than 60 dBA ProActive 1 year service plan2 THD input filter Installation3 7x24 startup Line up and match options cabinet containing External maintenance bypass 42 pole distribution panel Branch o
11. on the length of the AC outage This prevents severe battery discharge if the system is lightly loaded The intelligent communications capability of the Powerware P93 family of UPS means improved reliability easier network power management and expanded network communications With both hardware and software communications options Powerware provides the right communications solution for your specific situation LanSafe LanSafe version 5 delivers comprehensive support including graceful remote shutdown of UPS systems and network monitoring tools via serial USB and network connectivity options LanSafe s exclusive SafetyNet Technology provides Network Shutdown functionality and enables network administrators to shut down the most critical equipment last Powerware Extensions for IBM Director Powerware Extensions for IBM Director provide seamless integration of Powerware UPSs into the Director management system The Extensions for IBM Director simplify network management tasks for critical elements of server power protection System administrators can easily monitor diagnose configure set alarms schedule self tests check battery gather inventory information and control Powerware UPSs network wide from a single console within IBM Director PowerVision PowerVision power management software can monitor up to 64 network devices provide data archiving and analysis to pre vent power problems and offers sophisticated notification plus Modbus
12. p to 17 minutes of backup at full load The batteries are easily accessible and main tained through front access slide out trays DC Expert Plus internal battery management system significantly enhances battery life Ideal applications iSeries 870 and 890 pSeries 655 670 and 690 Enterprise Storage Server Model 800 Cluster Server 1650 Powerware P93 Advanced Technology Advanced ergonomically designed user interface panel Easily accessed from a standing position panel is tilted 15 degrees for optimum viewing Large LCD panel for graphic displays 4 line by 40 characters LED status indicators Soft keys provide easy navigation through info screens Smart Load Off button prevents unintentional load losses Multi lingual LCD panel meets global requirements Current status history events and alarms and an active mimic bus can be viewed The Powerware P93 offers a complete feature set to deliver the highest performance in the 20 kVA range of UPS Whether chosen for an IT or facility environment locally or remotely located the Powerware P93 is the only choice to keep your business in business around the clock Superior cooling design Air filters prevent contaminants from entering the UPS Redundant fans provide continuous operation without derating if a fan fails Fan failure detection and notification Load based fan speed control maximizes fan life and efficiency while minimizing audible noise and heat dissipatio
13. ure Code Part Number Minimum Maximum Concurrent with UPS purchase 155102012 001 7001 97P2657 0 4 Non concurrent to UPS purchase 155102013 001 7002 97P2658 0 4 Connectivity ConnectUPS X Slot Web SNMP xHub card 10 100Mb The ConnectUPS X Web SNMP xHub card provides real time UPS monitoring and control of power throughout both 100Mb and 10Mb networks When used in conjunction with NetWatch Client software it also provides graceful shutdown of the operating system of up to 255 computers powered by a single UPS The advanced features of the ConnectUPS X include Real time enterprise wide monitoring provides valuable information for analysis of critical power conditions and problem identification Supports 100Mb and 10Mb Ethernet networks Built in three ports switching hub adds three 10 100Mb network connections with no additional expense Monitoring via Web using computer through standard Web Browsers e g Internet Explorer and Netscape PDA or cell phone provides easy anywhere anytime access Monitoring via SNMP using Network Management Software packages e g Tivoli CA Unicenter and HP Openview Analysis of chronic power problems and determination of trends through data logging and sophisticated graphic tools ConnectUPS MultiServer Card The ConnectUPS MultiServer card is an X Slot connectivity device that provides serial connection to up to five computers for unattended graceful shutdown and power monitoring The card operat
14. utput breakers with output distribution cables and receptacles outlets with various configurations to support a variety of device configurations Support dual redundant power needs of IBM devices Powerware P93 1 Requires customer provided phone line Includes one year ProActive Service 2 Additional years of ProActive Service available See Options section for details 3 When purchased with Powerware Field Installation PN 10300671 IBM PN 973604 Connectivity what you need by application Solution zSeries iSeries pSeries xSeries Storage Networking LanSafe software x x LanSafe software amp ConnectUPS MultiServer card IBM FC 2933 x x NetWatch software amp ConnectUPS Web SNMP card IBM FC 2934 x LPARS1 x x x IBM Director Snap in x x x PowerVision software x x x x x FORESEER Software x x x x x ConnectUPS relay card amp AS400 cable IBM FC 2936 x NOTE One 1 X Slot relay card and interface cable included with P93 1 Use ConnectUPS Web SNMP xHub card IBM FC 2934 to support LPAR POWER 4 Chip Set servers For pSeries configurations each LPAR needs a network connection and will install Powerware provided NetWatch or LanSafe V software DC Expert Plus Built in Battery Monitoring Real world business applications require a complete range of battery management and testing features including battery runtime remaining lifetime remaining battery health and notification to help make
15. ware P93 include Digital signal processing and pulse width modulation True pulse width modulation is achieved through the use of digital signal processing which enables the IGBTs to works at their highest capacity increasing system reliability and ensuring perfect power on the output Built in control area network CAN An integral internal and external Control Area Network CAN is incorporated into the Powerware P93 that assists in seamlessly integrating peripherals and options controllable from the control panel It also reduces the internal wiring connections required therefore increasing overall system reliability Superior cooling design The superior cooling design of the Powerware P93 draws from Powerware s extensive almost 40 years of industry and product development experience This design which features redundant fans ensures that more thermally sensitive areas are cooled first Comprehensive communications and user interface A large display mimic and control panel is ergonomically situated for operator interface with the unit The soft keypad helps guide the operator through all menus and setups A dedicated micro processor had been designed and engineered to provide full featured monitoring and extensive alarm history It allows for additional communica tion options like Internet accessibility Ethernet network links and modems Internal battery The Powerware P93 comes with internal batteries that provide u