Home
Powermate KLA1581009 User's Manual
Contents
1. button for 5 seconds The displayed pressure will blink 3 times and then be stored as the new pre set pressure for this button vil HE AN Gu Adjustable pressure setting default setting 90 PSI Pressing this button on the digital control panel will set the tank pres sure to a pre set PSI default setting is 90 PSI To change this pre set pressure setting to a different PSI adjust the pressure to your desired setting by using the or buttons Press and hold the 2 button for 5 seconds The displayed pressure will blink 3 times and then be stored as the new pre set pressure for this button 1 e LCD Display window This display will automatically show the regulated outlet pressure when the unit is on The on off icon and the tool icon will be shown on the dis play The display will automatically show the tank pressure when the unit is off but still plugged in if the pressure is not zero The bar on the right hand side of the LCD display window is a visual indicator of tank pressure When the bar reaches the top the pressure dis at 155 PSI and the compressor will turn off When the bar reaches the bottom the pressure is at 125 PSI and the compressor will turn on Change pressure display settings from PSI to BAR Press the On Off button to turn the unit on Press and hold the On Off button and the Tank pressure button at the same time for 5 seconds to enter the display setti
2. 4 Sujete el compresor muy bien si es necesario su transporte Debe liberarse la presi n del tanque antes de su transporte 200 2614 5 OVERVIEW VUE D ENSEMBLE Y RESUMEN GENERAL Enis BASIC AIR COMPRESSOR COMPONENTS Oilless air compressors are factory lubricated for life and do not require any oil The basic components of the air compressor are the elec tric motor pump digital control panel and tank The electric motor see A powers the pump The electric motor is equipped with an overload protector and an automatic reset If the motor becomes overheated the overload protector will shut it down to prevent damage to the motor When the motor sufficiently cools it will automatically restart The pump see B compresses the air and discharges it into the tank The tank see C stores the compressed air The digital control panel see D consists of the on off button E pressure adjustment up button F pressure adjustment down button G tank pressure indicator H tank pressure button I adjustable pressure setting button default 90 PSI J adjustable pressure setting button default 40 PSI K and a LCD display window L As compressed air is used and the pressure level in the tank drops to the kick in pressure the control board restarts the motor automatically without warning and the pump resumes compressing air The control board shuts down the motor when the air pressure in the tank reaches the cu
3. faut 90 PSI Appuyer sur ce bouton sur le panneau de commande num rique pour d finir la pression du r servoir par d faut en PSI le r glage par d faut est de 90 PSI Pour affecter un param tre de pression par d faut sur une autre valeur en PSI r gler la pression au niveau voulu l aide des boutons ou Appuyer sur le bouton 2 et le maintenir enfonc pendant 5 secondes La pression s affiche en clignotant 3 reprises avant d tre enregistr e en tant que nouveau param tre de pression par d faut pour ce bouton Fen tre de l cran cristaux liquides Cet cran affiche automatiquement la pression de sortie r gul e pen dant le fonctionnement de l appareil L ic ne on off et l ic ne outil s af fichent l cran Si la pression n est pas z ro l cran affiche automatiquement la pres sion du r servoir lorsque l appareil est arr t sans tre d branch La pression du r servoir est repr sent e par une barre sur la droite de la fen tre de l cran cristaux liquides Lorsque la barre arrive en haut PE pression est 155 PSI et le compresseur s arr te Lorsque la barre arrive en bas la pression est 125 PSI et le compresseur se met en marche Changer les param tres d affichage de la pression de PSI en BARS Appuyer sur le bouton On Off pour mettre l appareil en marche Appuyer sur le bouton On Off et sur celui de pression du r servoir en m me temps et les maintenir
4. le Fen GLOSSAIRE DES TERMES CFM Pieds cubes par minute une unit de mesure de d bit d air Bar Unit de mesure de pression d air Pression d ouverture Point de pression bas r gl en usine qui met en marche le moteur de la pompe pour remettre sous pression l air dans le r servoir Pression d arr t Point de pression haut r gl en usine qui arr te le moteur de la pompe et la hausse de pression dans le r servoir au del d un certain niveau Bien a r Qualifie un endroit o les gaz d chappement ou les vapeurs sont remplac s par de l air frais Circuit r serv Circuit lectrique r serv exclusivement au compresseur d air ASME American Society of Mechanical Engineers Soci t am ri caine des ing nieurs m caniciens Indique que les composants sont fabriqu s test s et exam in s selon les normes d finies par l ASME G CSA L association canadienne de normes Indique que les produits qui font avoir examin e cette inscrip tion avoir t fabriqu e test e et aux normes qui sont fix es par CSA L association canadienne de normes Etats Unis Indique que les produits qui font avoir fabriqu cette inscrip tion test et examin aux normes qui sont fix es par CSA Ces produits se conforment galement la norme 1450 d cU Es GLOSARIO DE TERMINOS l min Litros por minuto una unidad de la medida de flujo de aire Bar Es una unidad de medida de la presi n del ai
5. 1 PSI Presione el bot n de manera continua para incrementar r pidamente la presi n La presi n m xima regulada es de 125 PSI Ajuste de la presi n disminuir Al presionar este bot n del panel de control digital se disminuye la pre si n en l nea de la herramienta que est usando Cada vez que presione el bot n la presi n disminuir a raz n de 1 PSI Presione el bot n de manera continua para disminuir r pidamente la presi n Indicador de la presi n del tanque Este indicador cambiar a color rojo cuando el tanque sea presurizado Cuando no exista presi n en el tanque el indicador no ser visible Bot n de la presi n del tanque Al presionar este bot n se indicar el nivel de presi n del aire almace nado en el tanque y el icono del tanque aparecer en la pantalla No puede ser ajustado por el operario y no indica la presi n de l nea Al soltar el bot n la pantalla volver a mostrar la presi n regulada y el icono de la herramienta aparecer en la pantalla Configuraci n ajustable de la presi n ajuste por omisi n a 40 PSI Al presionar este bot n en el panel de control digital se configurar la presi n del tanque a una cantidad predeterminada de PSI el ajuste por omisi n es de 40 PSI Para modificar esta configuraci n predeterminada de PSI configure la presi n deseada utilizando los botones o Presione el bot n 1 durante 5 segundos La presi n indicada parpadear 3 veces y desp
6. 16 NOTE In cold climates drain the tank after each use to reduce problems with freezing of water condensation english CHECKING THE RELIEF VALVE Pull the relief valve daily to ensure that it is operating properly and to clear the valve of any possible obstructions english TESTING FOR LEAKS Check that all connections are tight A small leak in any of the hoses or pipe connections will substantially reduce the per formance of your air compressor If you suspect a leak spray a small amount of soapy water around the area of the suspect ed leak with a spray bottle If bubbles appear repair or replace the faulty component Do not overtighten any connections english STORAGE Before storing the compressor for a prolonged period use an air blow gun to clean all dust and debris from the compres sor Disconnect the power cord and coil it up Pull the pressure relief valve to release all pressure from the tank Drain all moisture from the tank Cover the entire unit to protect it from moisture and dust De ENTRETIEN ARE pour viter les risques de blessures arr tez et d branchez toujours le compresseur et lib rez toute la pression d air dans le circuit avant de proc der l entretien L entretien r gulier de l appareil permettra d assurer un fonctionnement sans probl mes Votre compresseur d air lec trique est un appareil de haute qualit toutefois m me les machines de haute qualit n cessi
7. EMPLOI 15 16 ASSEMBLAGE 226 mime e Re de 7 Mise en marche quotidienne 15 Assemblage du compresseur 7 AM E 16 COMMANDES DU COMPRESSEUR 9 ENTRETIEN 3542 i ad part dun 17 Panneau de commande num rique 9 Vidange du r servoir 17 Soupape de d charge 11 V rification de la soupape de d charge 17 Sortie de conduite d air 11 Essai d tanch it 17 SP CIFICATIONS DE L ALIMENTATION Entreposage 17 LECTRIQUES man Ru Lame en aegis 12 13 ENTRETIEN P RIODIQUE 18 C blage lectrique 12 D PANNAGE 2 ie Aa dessine 20 Rallonges 12 13 GLOSSAIRE spot a nee 23 ms l N D l C E PAUTAS DE SEGURIDAD 5 MARCHA INICIAL DEL BOMBA 14 RESUMEN GENERAL 6 INSTRUCCIONES OPERATIVAS 16 Componentes b sicos del compresor de aire 6 Arranque diario 16 MONTAJE 300 rita ete 7 Pa rn Acacia 16 Montaje del compressor 7 MANTENIMIENTO 17 CONTROLES DEL COMPRESOR 10 Desag e del tanque 17 Panel de Control Digital 10 Revisi n de la v lv
8. an operating compressor d Remove the compressor from the shipping pallet or carton and place it on the floor or a hard level surface The compressor must be level to ensure proper drainage of the moisture in the tank Connect an air hose not included to the compressor hose outlet see page 11 Sortez le compresseur d airde sa bo te Inspectez le pour vous assurer qu il n est pas endommag S i a t endommag pendant le transport r f rez vous l tiquette de transport et d clarez les dommages aux transporteur Faites cette d marche imm diatement tant donn les d lais limites des demandes d indemnisation Le carton doit contenir e compresseur d air poign e manuel de l op rateur et manuel de pi ces V rifiez l tiquette du num ro de s rie du compresseur pour vous assurer qu il s agit bien du mod le command et que la pression nominale est conforme l utilisation pr vue Positionnez le compresseur conform ment aux recommandations suivantes a Placez le compresseur pr s d une prise de courant mise la terre voir INSTRUCTIONS DE MISE LA TERRE p 13 b Le compresseur doit tre situ au moins 12 pouces 31 cm du mur ou de tout objet faisant obstruction dans un endroit propre et bien a r pour assurer une circulation d air suffisante et un bon refroidissement c Dans des climats froids entreposez les compresseurs portatifs dans un b timent chauff lorsqu ils ne sont pas
9. cable de extensi n sean en el cable o longitud excesiva adecuados del cable de extensi n Pintura de pistola en las piezas Haga que lo revisen en un centro de servicio No opere el compre Posiblemente el motor est Haga que lo revisen en un centro de servicio A pe 22 200 2614 9 Engish GLOSSARY OF TERMS CFM Cubic feet per minute a unit of measure of air flow PSI Pounds per square inch a unit of measure of air pressure Kick in pressure Factory set low pressure point that starts the compressor to repressurize the tank to a higher pressure Kick out pressure Factory set high pressure point that stops the compressor from increasing the pressure in the tank above a certain level Well ventilated A means of providing fresh air in exchange for dangerous exhaust or vapors Dedicated circuit An electrical circuit reserved for the exclusive use of the air compressor ASME American Society of Mechanical Engineers Indicates that the components are manufactured tested and inspected to the specifications set by ASME GB CSA Canadian Standards Association Indicates that the products that have this marking have been manufactured tested and inspected to standards that are set by CSA 59 Canadian Standards Association USA Indicates that the products that have this marking have been manufactured tested and inspected to standards that are set by CSA These products also conform to U L standard 1450
10. d bit PCM et la pression fournis par le compresseur celui ci doit tre plus puissant La plupart des accessoires sont valu s 25 de leur d bit PCM r el en fonctionnement continu La lecture du Tension insuffisante Fournir la tension ad quate Si une rallonge est utilis e essayer manom tre chute lors sans de l utilisation d air C bles lectriques trop longs Consulter un lectricien Voies d air obstru es Contacter un centre d entretien agr Manque d a ration Replacer le compresseur dans un endroit frais sec et offrant une bonne circulation d air Surfaces de refroidissement sales Nettoyer les surfaces de refroidissement de la pompe et du moteur Fuite de soupape Remplacer les pi ces us es et installer de nouveaux joints Le moteur cale Tension insuffisante Fournir la tension ad quate La soupape de s ret La pression du r servoir d passe la Contacter un centre d entretien agr s ouvre limite normale D faillance du tableau de commande Le moteur ne d marre La pression du r servoir d passe lalLe moteur d marre automatiquement lorsque la pression du r ser pas limite pr r gl e du manocontacteur voir chute sous la pression d enclenchement du manocontacteur Le limiteur de surcharge s est Laisser le moteur refroidir et le limiteur de surcharge se r armera d clench automatiquement apr s quelques minutes Fusible grill ou disjoncteur e Remplacer le fusible ou r armer le disjoncteur Ne p
11. de commande Le bouton 1 est pr r gl sur 40 PSI et le bouton 2 sur 90 PSI Pour plus d informations sur la programmation de ces l ments en fonction de vos propres param tres personnalis s se reporter la page 8 5 Pour v rifier la pression du r servoir appuyer sur le bouton de pression du r servoir et le maintenir enfonc Jusqu ce que le bouton soit rel ch un r servoir s affiche sur la fen tre de l cran cristaux liquides 15 MODE D EMPLOIY INSTRUCCIONES OPERATIVAS 1 Appuyer sur le bouton on off pour le placer en position OFF l ic ne on off et l ic ne outil ne s affichent plus dans re He zo z pressure set sure button le coin sup rieur gauche de l cran ting default ting default 2 D branchez le cordon d alimentation 40 PSI 90 PSI 3 R duisez la pression dans le r servoir par l orifice de sortie du tuyau Vous pouvez galement tirer sur l anneau de la soupape de d charge E et la maintenir ouverte pour lib rer la pression dans le r servoir CLONE L air et l humidit qui s chappent peuvent projeter des particules pouvant causer des blessures aux yeux Portez des lunettes de protection lorsque vous ouvrez le robinet de purge PRESETS PRESSURE 4 Ouvrez le robinet de petit diam tre voir B pour laisser l humidit sortir du r servoir Be spanish ARRANQUE DIARIO 1 Cierre la llave de descompresi n del tanque vea D p que DIGITECH H gal
12. en service pour r duire les probl mes de lubrification de d marrage du moteur et de gel de l eau produite par condensation 4 QUO La palette d exp dition n est pas con ue pour servir de base un compresseur en marche d Enlever le compresseur de la pallette d exp dition ou du carton et le placer sur une surface solide et de niveau Le compresseur doit tre de niveau pour assurer un bon drainage de l humidit du r servoir 200 2614 4 Raccorder le tuyau pneumatique non inclus la sortie du compresseur voir p 11 RDA MONTAJE DEL COMPRESOR 1 Desembale el compresor de aire Inspeccione la unidad para verificar que no sufri da os Si la unidad ha sido da ada durante el transporte comun quese con la empresa transportadora y complete una reclamaci n por da os Haga esto de inmediato porque existen aes de tiempo respecto a las reclamaciones por a os La caja debe contener los elementos siguientes compresor de aire manija manual del operador y manual de piezas Verifique el r tulo del n mero de serie del compresor para asegurarse de que haya recibido el modelo que pidi y que el mismo tenga la presi n nominal requerida para el uso deseado Ubique el compresor de acuerdo con las pautas siguientes a Ubique el compresor cerca de un tomacorriente el ctrico conectado a tierra consulte INSTRUCCIONES DE PUESTA A TIERRA vea 13 b El compresor debe estar a una distancia m
13. nima de 12 pulgadas 31 cm de cualquier pared u obstrucci n en un rea limpia y bien ventilada para asegurar que exista suficiente flujo de aire y enfriamiento c En climas fr os almacene el compresor port til en un edificio con calefacci n Esto reducir problemas de lubricaci n arranque del motor y congelamiento del agua de condensaci n EME La plataforma de embarque no est dise ada para servir de base de un compresor en operaci n d Separe el compresor de la plataforma de transportaci n y col quelo en el piso sobre una superficie dura y nivelada El compresor debe quedar nivelado para asegurar un drenaje adecuado del agua de humedad del tanque Conecte una manguera de aire no se incluye en la salida de la manguera del compresor vea p 11 COMPRESSOR CONTROLS DIGITAL CONTROL PANEL On Off button When the unit is plugged in and in the OFF mode pressing this button on the digital control panel turns the compressor on It is operated man ually but when in the ON mode it allows the compressor to start up and shut down automatically without warning upon air demand The on off icon and the tool icon will be shown on the LCD display when the unit is in the ON mode ALWAYS turn the unit OFF when the compres sor is not being used and before unplugging the compressor Pressure adjustment up Pressing this button on the digital control panel increases the line pres sure to the tool you are usi
14. so voids all warranties They have been preset at the factory for the maximum pressure of this unit Personal injury and or property damage may result if the control board or the relief valve are tampered with RISK OF BURSTING Do not use plastic or pvc pipe for compressed air Use only galvanized steel pipe and fittings for compressed air distribution lines RISK TO HEARING Always wear hearing protection when using an air compressor Failure to do so may result in hearing loss RISK TO BREATHING Never directly inhale the com pressed air produced by a compressor It is not suit able for breathing purposes The power cord on this product contains lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling Protect the air hose and electric cord from damage and puncture Inspect them weekly for weak or worn spots and replace if necessary To reduce the risk of electric shock do not expose to rain Store indoors Never operate the compressor if the power cord or plug are damaged Take the equipment to the nearest Authorized Service Center and have a Technician replace it Le French CONSIGNES DE S CURIT Les informations suivantes concernent VOTRE S CURIT et LA PROTECTION DU MAT RIEL CONTRE LES PANNES Pour vous aider identifier la nature de ces informations nous utilisons les symboles suivants Veuillez lire le manuel et pr
15. v lvula de alivio de La presi n del tanque excedi la Comun quese con un centro de servicio autorizado presi n se abre presi n normal de operaci n Falla en el tablero de control Comun quese con un centro de servicio autorizado 200 2614 21 Es CUADRO DE DETECCI N DE FALLOS Nota Los problemas de detecci n de fallos pueden tener causas y soluciones similares CAUSA POSIBLE SOLUCION El motor no funciona La presi n del tanque excede el El motor arrancar autom ticamente cuando la presi n del tanque l mite preestablecido del conmu disminuya hasta un valor menor de la presi n de activaci n del con tador activado por presi n mutador activado por presi n El protector de sobrecargas del Deje que el motor se enfr e y el conmutador de sobrecargas se motor se dispar restablecer autom ticamente Esto puede tardar varios minutos Fusible fundido o disyuntor dis Reemplace el fusible fundido o reajuste el disyuntor No use parado fusibles ni disyuntores de clasificaci n mayor que la especificada para su circuito de derivaci n e Verifique que el fusible sea adecuado El fusible Fusetron tipo T es aceptable e Verifique que el voltaje no sea bajo y que el tama o del cable de O AAA e Desconecte otros dispositivos del circuito Opere el compresor en ES La v lvula de retenci n se blo Quitela y limpiela o reempl cela PA oe Alambre de calibre inadecuado Verifique que el calibre y la longitud del
16. when opening petcock 4 Open the petcock see B to allow moisture to drain from the tank Em MISE EN MARCHE QUOTIDIENNE 1 Fermez le robinet de purge du r servoir D Tourner vers la droite 2 Branchez le cordon d alimentation AMEN La pompe et le moteur lectrique produisent des temp ratures lev es Pour viter les br lures et autres blessures NE z touchez PAS le compresseur quand il est en marche Laissez le refroidir avant de le manipuler ou d effectuer son entretien Ne laissez jamais les enfants s approcher du compresseur 3 Appuyer sur le bouton on off pour le placer en position ON l ic ne on off et l ic ne outil s affichent dans le coin sup rieur gauche de l cran A AVERTISSEMENT jamais d passer la gt pression de fonctionnement maximale de l outil Appuyer sur pour augmenter la pression et sur pour la diminuer 200 2614 Adjustable Button Adjustment Adjustment pressure set pressure set up down ting default ting default 40 PSI 90 PSI Tank pres sure button A KOBALT DOTEC Pewermate PRET PRESETS PRESSURE DIGITE PLUZ B OPEN e OUVERT n ABIERTO EA CLOSE Am FERM SC SE CIERRAN LS 4 Ajuster la pression de r glage sur la pression de fonctionnement de l outil en appuyant sur le bouton pour augmenter la pression et sur le bouton pour la diminuer ou utiliser les boutons de pr r glage sur le panneau
17. 115 volts Un cable muni d une prise de terre comme illustr ici doit tre utilis Veillez ce que le compresseur soit branch sur une prise de courant compatible avec la fiche Figure 1 N utilisez pas d adap tateur avec ce produit Si vous ne comprenez pas les instructions de mise la terre ou si vous doutez que le compresseur soit correctement mis la terre consultez un lectricien qualifi Ne modifiez pas la fiche fournie avec l appareil si elle ne s adapte pas la prise de courant faites installer une prise de courant correcte par un lec tricien qualifi ECS CABLEADO EL CTRICO Consulte el r tulo del n mero de serie del compresor de aire para ver los requerimientos de voltaje y amperaje de la unidad Use un circuito exclusivo Para el mejor rendimiento y un arranque confiable el compresor de aire debe conectarse en un circuito exclusivo tan cerca como sea posible de la caja de fusibles o del cortacircuito El compresor utilizar la capacidad m xima de un circuito de 15 amperios de una casa normal Si hay otros equipos el ctricos que est n consumiendo energ a del circuito al cual est conectado el compresor es posible que ste no arranque Un voltaje bajo o un circuito sobrecargado puede causar un arranque lento que causar que salte el interruptor de reposicionamiento del motor o el cortacircuito especialmente en condiciones de baja temperatura NOTA Se recomienda un disyuntor Si el com
18. C KOBALT Digital Operator Manual Manuel de l op rateur num rique Manual del Operador Digital English Oilless Single Stage Direct Drive Electric Air Compressors Em Sans l huile d une seul tape prise directe compresseurs d air lectriques Ems is Sin aciete de una sola etapa de mando directo compresores de aire el ctricos pressor 155 English WARNING Read and understand all safety precautions in this manual before operating Failure to comply with instructions in this manual could result in personal injury property damage and or voiding of your warranty The manufacturer WILL NOT be liable for any damage because of failure to follow these instructions o French AVERTISSEMENT Lisez et veillez bien comprendre toutes les consignes de s curit de ce manuel avant d utiliser l appareil Toute d rogation aux instructions contenues dans ce manuel peut entra ner l annulation de la garantie causer des blessures et ou des d g ts mat riels Le fabricant NE SAURA tre tenu responsable de dommages r sultant de l inobservation de ces instructions Es A ADVERTENCIA Lea y comprenda todas las precauciones de seguridad contenidas en este manual antes de utilizar esta unidad Si no cumple con las instrucciones de este manual podria ocasionar lesiones personales da os a la propiedad y o la anulaci n de su garantia El fabricante NO SERA responsable de ningun da o por no acatar estas instrucciones Pr
19. CLOSE FERM SE CIERRAN herramienta aparecer n en la esquina superior izquierda de la pantalla El compresor arrancar Permita el funcionamiento del compresor durante 15 minutos a fin de suavizar los componentes internos NOTA Si despu s de 15 minutos la unidad no opera correctamente AP GUELA INMEDIATAMENTE y p ngase en contacto con el Centro de Servicio 4 Despu s de 15 minutos presione el bot n de encendido apagado en la posici n de APAGADO OFF el icono on off y el icono de la herramienta ya no ser n visibles en la esquina superior izquierda de la pantalla 5 Cierre la llave de descompresi n vea D 6 Presione el bot n de encendido apagado on off para dejarlo en la posici n de encendido ON H galo girar hacia la derecha El compresor comenzar a funcionar llenar el tanque hasta la presi n de desconexi n y dejar de funcionar NOTA Al utilizar el aire comprimido el interruptor de presi n arrancar autom ticamente el motor NOTA Durante el ciclo de adaptaci n inicial habr un olor el ctrico leve como el motor cepilla el asiento Esto es normal para los motores universales y la voluntad dura por cerca de 5 minutos 200 2614 OPERATING INSTRUCTIONS 1 MODE D EMPLOI INSTRUCCIONES OPERATIVAS English DAILY STARTUP 1 Close the tank petcock see D Turn in the clockwise o direction 2 Plug in the power cord LATE High temperatures are generated by the electri
20. E SERVICO Realice el mantenimiento siguiente a los intervalos indicados a continuaci n Operaci n de todas las v lvulas de alivio de la presi n A diario Drenaje del tanque oocoococcoccnco eee eee eee etree eens A diario 18 200 2614 eo english TROUBLESHOOTING CHART Note Troubleshooting problems may have similar causes and solutions PROBLEM POSSIBLE CAUSE SOLUTION Low pressure or not Tank petcock is open Close petcock enough air Prolonged excessive use of air Decrease amount of air used or Compressor not large enough Check air requirement of accessory If it is higher than CFM and Compressor does not pressure supplied by compressor you need a larger compressor stop Most accessories are rated at 25 of actual CFM while running continuously stopping while not in DO NOT OVERTIGHTEN Air leaks from regulator Dirty or damaged regulator inter Replace regulator or internal parts or regulator does not reg nal parts ulate pressure Regulated pressure reading drops when air Compressor not large enough Check air requirement of accessory If it is higher than CFM and accessory is being used pressure supplied by compressor you need a larger compressor Most accessories are rated at 25 of actual CFM while running continuously Circuit breaker trips fuse Low voltage Furnish adequate power If using extension cord try without blows too often Excessive wire lengt
21. Le tableau de commande coupe le moteur lorsque la pression d air du r servoir atteint la pres sion de coupure Les fonctions de ces composants sont d crites aux pages 8 11 RDA COMPONENTES BASICOS DEL COMPRESOR DE AIRE Los compresores de aire sin aceite se lubrican en f brica para toda su vida til y no requieren aceite Los componentes b sicos del compresor de aire son el motor el ctrico la bomba el panel de control digital y el tanque El motor el ctrico vea A acciona la bomba El motor el ctrico est equipado con un protector contra sobrecargas y un reajuste autom tico Si el motor se sobrecalienta el pro tector contra sobrecargas lo apagar para evitar que sufra da os Cuando el motor se enfr e lo suficiente volver a arrancar autom ticamente La bomba vea B comprime el aire y lo descarga hacia el tanque El tanque vea C almacena el aire comprimido El panel de control digital ver D consiste en el bot n de encendido apagado E el bot n de ajuste de presi n aumentar F el bot n de ajuste de presi n disminuir G el indicador de presi n del tanque H el bot n de presi n del tanque I el bot n de configuraci n ajustable de presi n por omisi n a 90 PSI libras por pulgada cuadrada J el bot n de configuraci n ajustable de presi n por omisi n a 40 PSI K y un monitor LCD L Al utilizar el aire comprimido y cuando el nivel de presi n del tanque baja hasta la pr
22. ado debe hacer todas las preajustados de f brica para obtener la m xima conexiones de acuerdo con todos los c digos resi n en esta unidad Alterar el tablero de control o el cricos cree locales Nunca utilice un a v lvula de alivio puede producir lesiones e compresor el ctrico de aire en el exterior cuando est personales y o da os en la propiedad lloviendo ni lo coloque sobre una superficie mojada yds ya que esto podria causar descargas el ctricas 10 RIESGO DE EXPLOSION No use tuberia de plastico ni de PVC para el sistema de aire comprimido Use RIESGO DE LESIONES Esta unidad arranca gt s lo tuber a y conectores de acero galvanizado para autom ticamente SIEMPRE apague el compresor las l neas de distribuci n de aire comprimido quite el enchufe del tomacorrientes y purgue toda la presi n del sistema antes de realizar el servicio al compresor y cuando el compresor no est en uso No 11 RIESGO AL SENTIDO DEL O DO Siempre use utilice la unidad sin las cubiertas o sin el protector de protectores auditivos cuando use un compresor de la correa ya que podr a sufrir lesiones por el contacto aire Si no lo hace podr a sufrir p rdida de la audici n con las piezas m viles RIESGO DE EXPLOSION Verifique la presi n nominal m xima sugerida por el fabricante para las herramientas y los accesorios neum ticos La presi n de salida del compresor se debe regular de tal manera que nunca se exceda la presi n nomina
23. affichent dans le coin sup rieur gauche de l cran Le compresseur d marre Laissez tourner pendant 15 minutes pour roder les pi ces internes REMARQUE on Si apr s 15 minutes l appareil ne fonctionne pas correctement ARRETEZ LE IMM DIATEMENT et contactez le service apr s vente 4 Au bout d environ 15 minutes appuyer sur le bouton on off pour le placer en position OFF l ic ne on off et l ic ne outil ne s affichent plus dans le coin sup rieur gauche de l cran Fermez le robinet de purge D Enfoncez la touche marche arr t la position marche Tourner vers la droite Le compresseur d marre et remplit le r servoir jusqu la pression de fermeture puis s arr te REMARQUE On Une fois que suffisamment d air comprim est utilis le manostat relance automatiquement le moteur Pendant le cycle rodage initial il y aura une l g re odeur lectrique comme le moteur balaye le si ge C est normal pour les moteurs universels et la volont durent pendant environ 5 minutes RDA MARCHA INICIAL DE LA BOMBA 1 Abra la llave de descompresi n vea B H galo girar hacia la izquierda 2 Enchufe el cord n el ctrico 3 Presione el bot n de encendido apagado en la posici n de ENCENDIDO ON el icono on off y el icono de la REMARQUE 14 Adjustable pressure set ting default 90 PSI Tank pres sure button ting default 40 PSI PRESETS PRESSURE B OPEN OUVERT EA o ABIERTO
24. as utiliser de d clench fusible ou de disjoncteur d une valeur sup rieure la puissance du circuit e V rifier le fusible le type T Fusetron est acceptable e V rifier la faible tension et le calibre de la rallonge e D brancher les autres appareils du circuit Faire fonctionner le compresseur sur un circuit r serv Le clapet de retenue est bloqu D monter nettoyer ou remplacer a Calibre incorrect du fil ou rallonge V rifier le calibre et la longueur de la rallonge CE IA A Mauvaises connexions Contacter un centre d entretien agr Peinture vaporis e sur les pi ces Contacter un centre d entretien agr Ne pas faire fonctionner le internes du moteur Possibilit de moteur d fectueux Contacter un centre d entretien agr 200 2614 Es CUADRO DE DETECCI N DE FALLOS Nota Los problemas de detecci n de fallos pueden tener causas y soluciones similares Presi n baja o insufi El grifo de desag e del tanque Cierre el grifo de desag e el compresor no se aire detiene El compresor no es suficiente Verifique el requerimiento de aire del accesorio Si es mayor que el mente grande volumen por minuto CFM y la presi n suministrados por el compre sor necesita un compresor m s grande La mayor a de los acceso rios est n clasificados a un 25 del volumen real por minuto en funcionamiento continuo V lvula de retenci n restringida Qu tela y limpiela o reempl cela Hay un orif
25. branchez le cordon d ali mentation et enroulez le Tirez sur la soupape de d charge pour lib rer toute la pression dans le r servoir Evacuez toute l humidit du r servoir Couvrez tout l appareil pour le prot ger de l humidit et de la poussi re RDA MANTENIMIENTO CEE para evitar lesiones personales sempre apague y desenchufe el compresor y alivie toda la presi n de aire del sistema antes de realizar alg n tipo de servicio en el compresor de aire El mantenimiento regular asegurar una operaci n sin problemas Su compresor de aire con alimentaci n el ctrica representa lo mejor en ingenier a y construcci n sin embargo a n la maquinaria de mejor calidad requiere un mantenimiento peri dico Los elementos enumerados a continuaci n deben inspeccionarse de manera regular ms DESAGUE DEL TANQUE A AVERTENCIA La condensaci n se gt acumulara en el tanque Para evitar la corrosion del tanque desde el interior esta humedad debe ser drenada al final de cada dia de trabajo Asegurese de utilizar proteccion ocular Alivie la presi n de aire en el sistema y abra la llave de descompresi n que se encuentra en el fondo del tanque para drenar Vea B y D en las p ginas 14 y NOTA En climas fr os drene el tanque despu s de cada uso a fin de reducir los problemas por el congelamiento del agua de condensaci n ms REVISI N DE LA V LVULA DE ALIVIO Tire de la v lvula de alivio todos los d as para aseg
26. c motor and the pump To prevent burns or other injuries DO NOT touch the compressor while it is running Allow it to cool before handling or servicing Keep children away from the compressor at all times 3 Press the on off button to the ON position the on off icon and tool icon will show in the top left corner of the display LAIT never exceed the maximum working pressure of the tool Press the button to increase pressure and the button to decrease pressure 4 Adjust the regulated pressure to the working pressure of the tool by pressing the button to increase pressure and the button to decrease pressure or use the preset buttons on the control panel The 1 button is preset to 40 PSI and the 2 button is preset to 90 PSI For information on programming these to your own personalized settings refer to page 8 5 To see how much pressure is in the tank press and hold the tank pressure button down A tank will be displayed in the LCD display window until the button is released 1 Press the on off button to the OFF position the on off icon and the tool icon will no longer be visible in the top left corner of the display Unplug the power cord Reduce pressure in the tank through the outlet hose You can also pull the relief valve ring see F and keep it open to relieve pressure in the tank A Escaping air and moisture can propel debris that may cause eye injury Wear safety goggles
27. das las etiquetas cuando est rociando pinturas o materiales t xicos y siga las instrucciones de seguridad Use una careta respiratoria si existe la fume al rociar No roc e donde existan chispas o llama Mantenga el compresor tan lejos del lugar de rociado como sea posible uric x osibilidad de inhalar alg n producto al rociar Lea RIESGO DE EXPLOSION La corrosi n puede odas las instrucciones y aseg rese de que su careta debilitar el tanque Drene el agua condensada del respiratoria le proteja tanque despu s de cada uso para reducir la Ai oxidaci n Si detecta una fuga en el tanque reem 8 RIESGO DE LESIONES OCULARES Cuando utilice pl celo inmediatamente No suelde no perfore ni un compresor de aire siempre use gafas de seguridad modifique el tanque del aire de este compresor La aprobadas seg n ANSI Z87 1 Nunca dirija la boquilla soldadura o las modificaciones en el tanque del ni el rociador hacia una persona ni hacia alguna parte compresor de aire podr an deteriorar gravemente la del cuerpo El equipo puede causar una lesi n grave resistencia del tanque y causar una condici n si el rocio penetra en la piel extremadamente peligrosa Soldar o modificar el tanque de cualquier manera anular la garant a 9 RIESGO DE EXPLOSI N No toque el tablero de A control ni ajuste la v lvula de alivio por ninguna raz n RIESGO DE DESCARGA ELECTRICA Un Si lo hace anular la garant a Los dos fueron electricista autoriz
28. de presionar de descompresi n use gafas de seguridad el bot n BD sos PARADA 4 Abra la llave ver B para permitir drenar la humedad del tanque 1 Presione el bot n de encendido apagado en la posici n APAGADO OFF el icono on off y el icono de la herramienta ya no ser n visibles en la esquina superior izquierda de la pantalla 2 Desenchufe el cord n el ctrico 3 Reduzca la presi n en el tanque a trav s de la manguera de salida Tambi n puede tirar del anillo de la v lvula de alivio vea E y mantenerla abierta para aliviar la presi n en el tanque 16 200 2614 MAINTENANCE Y ENTRETIEN Y MANTENIMIENTO MAINTENANCE A WARNING To avoid personal injury always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor Regular maintenance will ensure trouble free operation Your electric powered air compressor represents high quality engineering and construction however even high quality machinery requires periodic maintenance The items listed below should be inspected on a regular basis DRAINING THE TANK LATE condensation will accumulate in gt the tank To prevent corrosion of the tank from the inside this moisture must be drained at the end of every workday Be sure to wear protective eyewear Relieve the air pressure in the system JE and open the petcock on the bottom of the tank to drain See B and D on pages 14 15 and
29. e debe conectarse en un tomacorriente que est bien instal ado y conectado a tierra de acuerdo con todos los c digos y orde nanzas locales y AMA La instalaci n incorrecta del enchufe de conexi n a tierra puede causar un riesgo de descarga el ctrica En caso de ser necesario reparar o cambiar el cord n o el enchufe no conecte el alambre de conexi n a tierra en ninguno de las terminales de pata plana El alambre de conexi n a tierra tiene aislamiento de color verde con rayas amarillas o sin ellas Este producto se debe usar en un circuito de 115 voltios nomi nales Se deber usar un enchufe con un terminal conectado a tierra tal como el mostrado aqu Aseg rese de que el producto est conectado a un tomacorri ente que tenga la misma configuraci n que el enchufe V ase la Figura 1 No debe usarse ning n adaptador con este producto Consulte con un electricista capacitado si no comprende com pletamente las instrucciones de conexi n a tierra o si tiene dudas con respecto a si el producto est correctamente conectado a tier ra No modifique el enchufe provisto si no encaja en el tomacorri ente haga que un electricista capacitado instale un tomacorriente adecuado Figure 1 Figura 1 Bo te prises de terre Caja de tomacorriente puesta a tierra N Prise de courant mise la terre Tomacorriente puesta a tierra 115 VOLTS 15 AMP RES 115 VOLTIOS 15 AMPERIOS Broche de terre Pasador de
30. enfonc s pendant 5 secondes pour saisir le mode des param tres d affichage Appuyer sur le bouton d augmentation de la pression pour s lectionner l affichage en PSI Appuyer sur le bouton de baisse de la pression pour s lectionner l affichage en BARS Attendre 5 secondes pendant que l appareil m morise le param tre s lec tionn avant de s teindre Red marrer l appareil pour afficher la pression de fonctionnement de l ap pareil pour le param tre s lectionn CONTROLES DEL COMPRESOR PANEL DE CONTROL DIGITAL Bot n de encendido apagado Cuando se conecta la unidad y esta se encuentra en la posici n de apa gado OFF presione este bot n del panel de control digital para encen der el compresor Se opera manualmente pero cuando se encuentra en la posici n de encendido ON permite que el compresor se encienda y se apague autom ticamente sin advertencia dependiendo de la deman da de aire El icono de encendido apagado y el icono de la herramienta aparecer n en la pantalla LCD cuando la unidad est en la posici n de encendido ON SIEMPRE coloque la unidad en la posici n de apagado OFF cuando no est usando el compresor y antes de desconectarlo de la corriente Ajuste de la presi n aumentar Al presionar este bot n del panel de control digital se incrementa la pre si n en l nea de la herramienta que est usando Cada vez que presione el bot n la presi n incrementar a raz n de
31. ernal motor Have checked at service center Do not operate compressor in the parts paint spray area Possible defective motor Have checked at service center 200 2614 19 De D PANNAGE Remarque Les probl mes de d pannage peuvent avoir des causes et des solutions similaires Faible pression ou manque d air ou Compresseur pas assez puissant V rifier le d bit d air requis pour les accessoires S il est sup rieur compresseur fonction au d bit PCM et la pression fournis par le compresseur celui ci nant sans arr t doit tre plus puissant La plupart des accessoires sont valu s 25 de leur d bit PCM r el en fonctionnement continu Clapet de retenue obstru D monter nettoyer ou remplacer le clapet Fuite d un tuyau pneumatique V rifier ou remplacer au besoin Fuite du r servoir NEMJESINENA Remplacer imm diatement le r servoir NE PAS tenter une r paration D marrages et arr ts Fuite des raccords fr quents sans utilisa les raccords NE PAS TROP SERRER tion Fuite d air du r gula Pi ces du r gulateur sales ou Remplacer le r gulateur ou ses pi ces internes teur ou mauvaise r gu endommag es lation de la pression La lecture du Situation normale Si la pression chute trop ajuster le r gulateur pendant l utilisation manom tre chute lors de l accessoire de l utilisation d air Compresseur pas assez puissant V rifier le d bit d air requis pour les accessoires S il est sup rieur au
32. esi n de arranque el tablero de control reinicia autom ticamente el motor sin advertencia y la bomba comienza a comprimir el aire El tablero de control apaga el motor cuando la presi n del aire en el tanque alcan za la presi n de corte Las funciones de estos componentes se describen en las p ginas 8 a 11 200 2614 ASSEMBLY ASSEMBLAGE O English 1 4 Em ASSEMBLAGE DU COMPRESSEUR 1 ASSEMBLING THE COMPRESSOR Unpack the air compressor Inspect the unit for damage If the unit has been damaged in transit contact the carrier and complete a damage claim Do this immediately because there are time limitations to damage claims The carton should contain e air compressor handle e operator and parts manuals Check the compressor s serial label to ensure that you have received the model ordered and that it has the required pressure rating for its intended use Locate the compressor according to the following guidelines a Position the compressor near a grounded electrical outlet see GROUNDING INSTRUCTIONS page 12 b The compressor must be at least 12 inches 31 cm from any wall or obstruction in a clean well ventilated area to ensure sufficient air flow and cooling c In cold climates store portable compressors in a heated building when not in use This will reduce problems with motor starting and freezing of water condensation oP Ne The shipping pallet is not designed as a base for
33. g and opening the petcock on the bottom of the tank see the Maintence section of this manual for instructions English AIR LINE OUTLET Connect a Y female connector and an air hose to this outlet not included with some compressors see Figure 2 D Fench SOUPAPE DE D CHARGE Si le panneau de commande n arr te pas le moteur lorsque la pression atteint le niveau pr d fini cette soupape s ouvre automatiquement pour viter toute pressurisation excessive Pour l activer manuellement tirer sur l anneau de la soupape afin de lib rer la pression d air du r servoir voir Figure 2 Sch ma 1 ANN Risque d accident Toujours arr ter le compresseur avant de d placer ou T d effectuer tout type d intervention sur l appareil Figura 2 Retirer la fiche de la pression et vidanger toute la pression du syst me via le tuyau d vacuation ou bien en tirant sur l anneau de la soupape de d charge et ouvrir le robinet de petit diam tre pour obtenir des instructions ce sujet se reporter la rubrique Maintenance de ce manuel EOE Ferh SORTIE DE CONDUITE D AIR Brancher une fiche femelle de 0 63 mm 1 4 pouces et un tuyau d air sur cette sortie non fournis sur certains com presseurs se reporter au Sch ma 2 Bss V LVULA DE ALIVIO DE LA PRESI N Si el tablero de control no apaga el motor cuando la pre si n alcanza el nivel predeterminado esta v lvula se abrir autom t
34. g plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinance PLACES improper installation of the grounding plug can result in a risk of electric shock If repair or replacement of the cord or plug is necessary do not connect the grounding wire to either flat blade terminal The wire insulation having an outer surface that is green with or without yellow stripes is the grounding wire This product is for use on a nominal 115 volt circuit A cord with a grounding plug as shown here shall be used Make sure that the product is connected to an outlet hav ing the same configuration as the plug see Figure 1 No adapter should be used with this product 12 Check with a licensed electrician if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a licensed electrician De C BLAGE LECTIQUE Pour vous renseigner sur les normes d intensit et de ten sion de l appareil r f rez vous l tiquette du num ro de s rie du compresseur d air Utilisez un circuit s par Pour obtenir le meilleur rendement possible et une mise en marche fiable le compresseur d air doit tre install sur un circuit s par aussi pr s que possible d une bo te fusibles ou d un disjoncteur Le comp
35. h Consult electrician Restricted air passages Contact authorized service center Overheating Poor ventilation Relocate compressor to an area with cool dry and well circulated air Dirty cooling surfaces Clean all cooling surfaces of pump and motor thoroughly Leaking valve Replace worn parts and reassemble with new seals Motor stalls Low voltage Furnish adequate power Pressure relief valve Tank pressure exceeded normal Contact authorized service center opens operating pressure Control board failure Contact authorized service center Motor will not run Tank pressure exceeds preset Motor will start automatically when tank pressure drops below pressure switch limit kick in pressure of pressure tank Motor overload protection has Let motor cool off and overload switch will automatically reset This tripped may take several minutes Fuse blown or circuit breaker e Replace blown fuse or reset circuit breaker Do not use fuse or tripped circuit breaker with higher rating than specified for your branch circuit e Check for proper fuse Fusetron type T is acceptable e Check for low voltage and proper extension cord size e Disconnect other applications from circuit Operate compressor on a dedicated circuit Check valve stuck open Remove and clean or replace Wrong wire gauge in extension Check for proper gauge and extension cord length cord Loose electrical connections Contact authorized service center Paint spray on int
36. icamente para evitar un exceso de presi n Para oper arla manualmente jale el anillo de la v lvula para liberar la presi n del aire en el tanque ver Figura 1 A ADVERTENCIA Riesgo de lesiones Antes de transportar o darle cualquier tipo de servicio a la ay unidad recuerde siempre apagar el compresor retirar el cable del contacto y eliminar toda la presion del sistema a trav s de la manguera de salida o bien jalando el anillo de la valvula de liberacion y abriendo la perilla que se encuentra al fondo del tanque consulte las instrucciones que aparecen en la secci n de Mantenimiento de este manual Bss SALIDA DE LA LINEA DE AIRE Conecte un enchufe hembra de 4 de pulgada y una manguera de aire a esta salida no incluidos con algunos com presores ver Figura 2 200 2614 11 ELECTRICAL POWER REQUIREMENTS SP CIFICATIONS DE L ALIMENTATION LECTRIQUE REQUERIMIENTOS DE ALIMENTACI N EL CTRICA english ELECTRICAL WIRING Refer to the air compressor s serial label for the unit s volt age and amperage requirements Use a dedicated circuit For best performance and reliable starting the air compressor must be plugged into a dedicated circuit as close as possible to the fusebox or circuit breaker The compressor will use the full capacity of a typical 15 amp household circuit If any other electrical devices are drawing from the compressor s circuit the compressor may fail to start Low v
37. icio en la manguera Rev sela y reempl cela si es necesario de aire Fugas en el tanque A DN NA Reemplace inmediatamente el tanque NO intente repararlo Sellos expulsados Reemplace todos los sellos defectuosos Fugas en la v lvula Reemplace las piezas desgastadas y vuelva a montar usando sellos pa AN Arranque y detenci n Las conexiones tienen fugas Revise las conexiones con agua jabonosa Apriete o vuelva a sellar se est usando Reemplace las piezas desgastadas y vuelva a montar usando sellos nuevos Reemplace todos los sellos defectuosos Fugas de aire del regu Piezas internas del regulador Reemplace el regulador o las piezas internas lador o el regulador no sucias o da adas regula la presi n La lectura del Es normal Si la presi n disminuye demasiado ajuste el regulador mientras use man metro regulado dis el accesorio minuye cuando se est El compresor no es suficiente Verifique el requerimiento de aire del accesorio Si es mayor que el usando el accesorio de mente grande volumen por minuto CFM y la presi n suministrados por el compre aire sor necesita un compresor m s grande La mayor a de los acceso rios est n clasificados a un 25 del volumen real por minuto en funcionamiento continuo los fusibles se queman co intente operar sin l con mucha frecuencia con buena circulaci n sucias bomba y del motor nuevos El motor se atasca Bajo voltaje Proporcione la potencia adecuada La
38. inted in U S A 200 2614 Rev A_8 06 nish TABLE OF CONTENTS SAFETY GUIDELINES 3 BREAK IN OF THE PUMP 14 OVERVIEW 25e do Rte ca ata em a 6 OPERATING INSTRUCTIONS 15 Basic Air Compressor Components 6 Daily Startup a sea ie A eines 15 ASSEMBLY 3 tirar Dern hd Bie Mad ees 7 SHUIGOWN ae a paaa a Seas eye Re Lt nt 15 Assembling the Compressor 7 MAINTENANCE 17 COMPRESSOR CONTROLS 8 Draining the Tank 17 Digital Control Panel 8 Checking the Relief Valve 17 Pressure Relief Valve 11 Testing for Leaks 17 Air Line Outlet 11 Storage ove sae ren Be E bn 17 ELECTRICAL POWER REQUIREMENTS 12 SERVICE INTERVAL 18 Electrical Wiring 12 TROUBLESHOOTING CHART 19 Extension Cords 12 GLOSSARY OF TERMS 23 Grounding Instructions 12 o TABLE DES MATIERES CONSIGNES DE S CURIT 4 Instructions de mise la terre 13 VUE D ENSEMBLE 6 RODAGE DE LA POMPE 14 l ments de base du compresseur d air 6 MODE D
39. l m xima de la herramienta Antes de conectar o retirar 13 El cable el ctrico en este producto contiene el plomo accesorios alivie toda presi n del tubo 3 un producto qu mico sabido al estado de California RIESGO PARA LA RESPIRACI N Nunca inhale directamente el aire comprimido producido por un compresor No es adecuado para respirarly para causar el c ncer y el nacimiento deserta o el otro da o reproductivo Manos de la colada despu s de dirigir PRECAUCI N Or CAUCIO 5 Proteja la manguera de aire y el conducto el ctrico 1 Elimine la humedad del tanque todos los d as contra da os y pinchaduras Inspecci nelos todas las Un tanque limpio y seco ayudar a evitar la corrosi n semanas para comprobar que no existen zonas 2 Tire del anillo de la v lvula de alivio de la presi n OS y reempl celos si fuera todos los d as para asegurarse de que la v lvula est 7 funcionando adecuadamente y para eliminar cualquier 6 Para reducir el riesgo de choque el ctrico proteja la obstrucci n en la v lvula unidad de la lluvia Almacene en el interior 3 A fin de lograr una ventilaci n adecuada para el 7 Nunca opere el compresor si el cable de energ a o el enfriamiento el compresor debe mantenerse a un conector est n da ados Lleve el equipo al Centro de m nimo de 31 cm 12 pulgadas de la pared m s Servicio Autorizado m s cercano y p dale a un t cnico cercana en una zona bien ventilada que lo reemplace
40. ment au centre de service autoris le plus proche et demandez un technicien de le remplacer 200 2614 Es PAUTAS DE SEGURIDAD La informaci n que sigue se refiere a la protecci n de SU SEGURIDAD y la PREVENCI N DE PROBLEMAS DEL EQUIPO Como ayuda para reconocer esta informaci n usamos los siguientes s mbolos Lea por favor el manual y preste atenci n a estas secciones EA UN POSIBLE RIESGO QUE CAUSAR LESIONES GRAVES O LA P RDIDA DE LA VIDA PRESENTS un RIESGO POTENCIAL QUE PODR A PROVOCAR GRAVES LESIONES O MUERTE 117 ee UN RIESGO POTENCIAL QUE PODRIA PROVOCAR LESIONES LEVES O DA AR EL EQUIPO 1 M pa 2 e Y amp e F producen altas temperaturas Para prevenir RIESGO DE INCENDIO O EXPLOSION Nunca roc e quemaduras u otro tipo de heridas NO TOQUE la bomba el m ltiple ni el tubo de transferencia mientras la bomba se est funcionando Permita que se enfr e antes de manipularlos o realizar el servicio necesario l quidos inflamables en un rea confinada Es normal que el motor y el interruptor de presi n produzcan chispas al estar en funcionamiento Si las chispas entran en contacto con los vapores de la gasolina o Mantenga a los ni os alejados del compresor en todo con otros disolventes stos podr an encenderse momento causando un incendio o una explosi n Siempre A opere el compresor en un lugar bien ventilado No 7 RIESGO PARA LA RESPIRACI N Aseg rese de leer to
41. moisture from the tank on a daily basis A clean dry tank will help prevent corrosion Pull the pressure relief valve ring daily to ensure that the valve is functioning properly and to clear the valve of any possible obstructions To provide proper ventilation for cooling the compressor must be kept a minimum of 12 inches 31 cm from the nearest wall in a well ventilated area Fasten the compressor down securely if transporting is necessary Pressure must be released from the tank before transporting 200 2614 RISK OF BURNS High temperatures are generated by the pump and manifold To prevent burns or other injuries DO NOT touch the pump manifold or transfer tube while the pump is running Allow them to cool before handling or servicing Keep children away from the compressor at all times RISK TO BREATHING Be certain to read all labels when you are spraying paints or toxic materials and follow the safety instructions Use a respirator mask if there is a chance of inhaling anything you are spraying Read all instructions and be sure that your respirator mask will protect you RISK OF EYE INJURY Always wear ANSI Z87 1 approved safety goggles when using an air compressor Never point any nozzle or sprayer toward a person or any part of the body Equipment can cause serious injury if the spray penetrates the skin RISK OF BURSTING Do not tamper with the control board or adjust the relief valve for any reason Doing
42. moke while spraying Do not spray where sparks or flame are present Keep compressor as far from spray area as possible RISK OF BURSTING Rust can weaken the tank Drain the condensed water from the tank after each use to reduce rusting If a leak is detected in the tank replace the tank immediately Do not weld drill or modify the air tank of this compressor Welding or modifications on the air compressor tank can severely impair tank strength and cause an extremely hazardous condition Welding or modifying the tank in any manner will void the warranty RISK OF ELECTRICAL SHOCK A licensed electrician in accordance with all local and national codes must install all wiring Never use an electric air compressor outdoors when it is raining or on a wet surface as it may cause an electric shock RISK OF INJURY This unit starts automatically ALWAYS shut off the compressor remove the plug from the outlet and bleed all pressure from the system before servicing the compressor and when the compressor is not in use Do not operate the unit with the shroud removed Serious injury could occur from contact with moving parts RISK OF BURSTING Check the manufacturer s maximum pressure rating for air tools and accessories Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating of the tool Relieve all pressure through the hose before attaching or removing accessories 4 Ge 1 2 Drain the
43. n de la garantie RISQUE DE CHOC LECTRIQUE Un lectricien agr doit installer le c blage conform ment aux codes d lectricit nationaux et locaux N utilisez jamais un compresseur d air lectrique l ext rieur qang il pleut ou sur une surface mouill e sous peine e vous exposer une d charge lectrique RISQUE DE BLESSURE Cet appareil se met en marche automatiquement Arr ttez TOUJOURS le compresseur d branchez le de la prise de courant et urgez toute la pression du circuit avant de proc der entretien du compresseur ou lorsque vous ne l utilisez pas N utilisez pas l appareil sans les protections ou le garde courroie Risque de blessures graves en cas de contact avec les pi ces en mouvement 5 RISQUE D CLATEMENT V rifiez les sp cifications e de pression maximum recommand es par le fabricant W E pour les outils et les accessoires pneumatiques La ression de sortie du compresseur doit tre r gl e de acon ne jamais d passer la pression maximum nominale de l outil D pressurisez enti rement le tuyau avant de raccorder ou de d brancher des accessoires EN 1 Vidangez tous les jours l humidit accumul e dans le r servoir Pour viter la corrosion le r servoir doit tre propre et sec 2 Tirez tous les jours sur l anneau de la soupape de d charge pour vous assurer qu elle fonctionne correctement et liminer toutes les obstructions possibles de la soupape 3 Pour ass
44. ng Each time the button is pressed it increases the pressure by 1 PSI Hold the button down to rapidly increase the pressure The maximum regulated pressure is 125 PSI Pressure adjustment down Pressing this button on the digital control panel decreases the line pres sure to the tool you are using Each time the button is pressed it decreases the pressure by 1 PSI Hold the button down to rapidly decrease the pressure Tank pressure indicator This indicator will be red when the tank is pressurized When there is zero tank pressure the indicator will not be visible GDH never Exceed the maximum working pressure of the tool Press the button to increase pressure and the button to decrease pressure Tank pressure button Pressing this button on the digital control panel will show the pressure level of the air stored in the tank and the tank icon will be shown in the display It is not adjustable by the operator and does not indicate line pressure Releasing this button will return the display to regulated pressure and the tool icon will be shown in the display Adjustable pressure setting default setting 40 PSI Pressing this button on the digital control panel will set the tank pres sure to a pre set PSI default setting is 40 PSI To change this pre set pressure setting to a different PSI adjust the pressure to your desired setting by using the or buttons Press and hold the 1
45. ngs mode Press the pressure up button to select the display to be in PSI Press the pressure down button to select the display to be in BAR Wait for 5 seconds and the unit will memorize the selected setting and turn off Restart the unit to view the unit operating pressure in the selected set ting 200 2614 COMMANDES DU COMPRESSEUR a French La y ARENA ne jamais d passer la pression de fonction nement nominale de l outil Appuyer sur pour augmenter la pression et sur pour la diminuer 200 2614 PANNEAU DE COMMANDE NUMERIQUE Bouton On Off Une fois l appareil branch et en mode OFF arr t appuyer sur ce bou ton sur le panneau de commande num rique pour mettre le com presseur en marche Il est actionn manuellement mais en mode ON Marche il commande le d marrage et l arr t automatique du com presseur sans avertissement sur appel d air L ic ne on off et l ic ne outil s affichent sur l cran cristaux liquides lorsque l unit est en mode ON TOUJOURS arr ter l appareil en position OFF lorsque le com presseur n est pas utilis et avant de le d brancher R glage de la pression hausse En appuyant sur ce bouton la pression de canalisation sur l outil utilis augmente La pression augmente d un 1 PSI chaque fois que ce bou ton est activ Maintenir le bouton enfonc pour augmenter rapidement la pression La pression de r glage maximale es
46. o girar hacia la derecha 2 Enchufe el cord n el ctrico PLUS NEJELOLS El motor el ctrico y la bomba producen altas temperaturas Para evitar quemaduras y otras lesiones NO toque el compresor durante su funcionamiento Permita que se enfr e antes de manipular o realizar el servicio Mantenga a los ni os alejados del compresor en todo momento 3 Presione el bot n de encendido apagado en la posici n de ENCENDIDO ON el icono on off y el icono de la herramienta aparecer n en la esquina superior izquierda de la pantalla NELLY nunca exceda la presi n m xima de funcionamiento de la herramienta Presione el bot n para incrementar la presi n y el bot n para disminuirla 4 Ajuste la presi n regulada a la presi n de trabajo de la OPEN herramienta con el bot n para incrementarla y OUVERT A A ABIERTO el bot n para disminuirla o bien utilice los botones e predeterminados del panel de control El bot n 1 est preestablecido a 40 libras PSI y el bot n 2 est preestablecido a 90 PSI Para mayor informaci n sobre la programaci n personalizada de estos ajustes consulte la p gina8 1e RESUME El aire y la humedad que 5 Para saber cu nta presi n tiene el tanque mantenga i 3 escapan del tanque pueden arrojar desechos que presionado el bot n de la presi n del tanque Aparecer podr an causarle da o en los ojos Al abrir la llave un tanque en la pantalla LCD hasta que deje
47. oltage or an overloaded circuit can result in sluggish starting that causes the motor overload protection system or circuit breaker to trip especially in cold conditions NOTE Acircuit breaker is recommended If the air com pressor is connected to a circuit protected by a fuse use dual element time delay fuses Buss Fusetron type T only english EXTENSION CORDS NOTE Avoid use of extension cords For optimum performance plug the compressor power cord directly into a grounded wall socket Do not use an exten sion cord unless absolutely necessary Instead use a longer air hose to reach the area where the air is needed If use of an extension cord cannot be avoided the cord should be no longer than 100 feet and be a minimum wire size of 12 gauge AWG Do not use a 16 or 14 gauge extension cord Use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the product Make sure your extension cord is in good condition An undersized cord will cause a drop in line voltage resulting in loss of power and overheating The smaller the gauge number the heavier the cord English GROUNDING INSTRUCTIONS This product should be grounded In the event of an elec trical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate groundin
48. presor de aire se conecta a un circuito protegido por un fusible utilice fusibles temporizados de doble elemento s lo Buss Fusetron tipo T RDA CORDONES PROLONGADORES NOTA Evite el uso de cordones prolongadores Para obtener un rendimiento ptimo enchufe el cord n el c trico del compresor directamente en un tomacorriente de pared conectado a tierra No use un cord n prolongador a menos que sea absolutamente necesario 200 2614 larga para llegar a la zona donde se requiere aire el cable no debe tener una longitud mayor que 30 m 100 pies y un alambre con calibre m nimo de 12 AWG No use cables de extensi n de calibre 14 ni 16 Use solamente un cord n de 3 alambres que tenga un enchufe de 3 patas y un recept culo de 3 ranuras que permita el enchufe del producto Aseg rese de que su cord n prolongador est en buenas condiciones Un cord n demasiado peque o causar una ca da en el voltaje de la l nea causando una p rdida en la energ a y un sobrecalentamiento Cuanto m s peque o sea el n mero de calibre tanto m s pesado ser el cord n RDA INSTRUCCIONES DE CONEXI N A TIERRA Este producto debe conectarse a tierra En el caso de un cor tocircuito el ctrico la conexi n a tierra reduce el riesgo de choque el ctrico pues ofrece un escape para la corriente el ctrica Este producto est equipado con un cord n que tiene un alambre de conexi n a tierra con su enchufe correspondiente El enchuf
49. puesta a tierra BREAK IN OF THE PUMP RODAGE DE LA POMPE 1 MARCHA DE LA BOMBA Ses BREAKINOFTHEPUMP_ Engish BREAK IN OF THE PUMP 1 Open the petcock see B Turn in the counterclockwise direction Plug in the power cord Press the on off button to the ON position the on off icon and the tool icon will show in the top left corner of the display The compressor will start Allow the compressor to run for 15 minutes to break in the internal parts on NOTE After about 15 minutes If the unit does not operate properly SHUT DOWN IMMEDIATELY and contact Product Service 4 After about 15 minutes press the on off button to the OFF position the on off icon and the tool icon will no longer be visible in the top left corner of the display Close the petcock see D Turn in the clockwise direction Press the on off button to the ON position The compressor will start and fill the tank to the kick out pressure and stop NOTE an As compressed air is used the control board will restart the motor automatically NOTE During the initial break in cycle there will be a slight electrical smell as the motor brushes seat This is normal for universal motors and will last for about 5 minutes De RODAGE DE LA POMPE 1 Ouvrez le robinet de purge B Tourner le bouton vers la droite Branchez le cordon d alimentation Appuyer sur le bouton on off pour le placer en position ON l ic ne on off et l ic ne outil s
50. re Presi n de conexi n Punto de presi n baja fijado en f brica que arranca el motor de la bomba para volver a presurizar el tanque de aire a una presi n m s elevada Presi n de desconexi n Punto de presi n alta fijado en f brica que impide que el motor de la bomba aumente la presi n en el tanque por enci ma de un cierto nivel Bien ventilado Un medio de proveer aire fresco para contrarrestar el escape de gases o los vapores peligrosos Circuito dedicado Un circuito el ctrico reservado para uso exclusivo del compre sor de aire 200 2614 ASME American Society of Industrial Engineers Indica que los componentes se fabricaron probaron y exami naron de acuerdo con las especificaciones establecidas por ASME CSA La asociaci n canadiense de los est ndares Indica que los productos que hacen esta marca haber sido fabricados haber sido probados y haber examinado a los est ndares que son fijados por CSA La asociaci n canadiense de los est ndares los E E U U Indica que los productos que hacen esta marca haber fabrica do probado y examinado a los est ndares que son fijados por CSA Estos productos tambi n se conforman con el est ndar 1450 de U L
51. resseur utilise toute la capacit d un circuit usage domestique typ ique Si d autres appareils lectriques tirent du courant sur le circuit du compresseur il est possible que le compresseur ne puisse pas d marrer Si la tension est insuffisante ou si le cir cuit est surcharg le d marrage risque d tre lent et d entra n er en cons quence le d clenchement du disjoncteur ou de l in terrupteur de remise en marche du moteur surtout s il fait froid REMARQUE Il est recommand d utiliser un disjoncteur Si le compresseur est branch sur un circuit prot g par un fusible utilisez des fusibles temporis s double l ment Buss Fusetron de type T seulement REMARQUE vitez d utiliser des rallonges Le foros RALLONGES Pour obtenir un rendement optimum branchez le c ble d alimentation du compresseur directement sur une prise de courant mise la terre N utilisez pas de rallonge sauf n ces sit absolue Utilisez plut t un tuyau flexible plus long pour atteindre la zone o l air est n cessaire S il l utilisation d une rallonge est in vitable le cordon lec trique ne doit pas d passer 30 m 100 pi et doit tre d un cali bre minimum de 12 AWG N utilisez pas une rallonge de cali bre 16 ou 14 Figure 1 Grounded Outlet Box N Grounded Outlet 115 VOLTS 15 AMP rounding Pin 200 2614 SPECIFICATIONS DE L ALIMENTATION LECTRIQUE _ REQUERIMIENTOS DE ALIMENTACION ELECTRICA Como alterna
52. t de 125 PSI R glage de la pression baisse En appuyant sur ce bouton la pression de canalisation sur l outil utilis diminue La pression diminue d un 1 PSI chaque fois que ce bouton est activ Maintenir le bouton enfonc pour r duire rapidement la pression Indicateur de pression du r servoir Lorsque le r servoir est sous pression le voyant s affiche en rouge Le voyant est invisible si la pression du r servoir est gale z ro Bouton de pression du r servoir Appuyer sur ce bouton pour afficher le niveau de pression de l air stock dans le r servoir L ic ne du r servoir s affiche l cran Il n est pas r glable par op rateur et n affiche pas la pression de canalisation Rel cher le bouton pour ramener l cran la pression de r glage et l ic ne outil s affiche l cran R glage des param tres de pression par d faut 40 PSI Appuyer sur ce bouton sur le panneau de commande num rique pour d finir la pression du r servoir par d faut en PSI le r glage par d faut est de 40 PSI Pour affecter un param tre de pression par d faut sur une autre valeur en PSI r gler la pression au niveau voulu l aide des boutons ou Appuyer sur le bouton 1 et le maintenir enfonc pendant 5 secondes La pression s affiche en clignotant 3 reprises avant d tre enregistr e en tant que nouveau param tre de pression par d faut pour ce bouton R glage des param tres de pression par d
53. t out pressure The functions of these components are described on pages 8 11 DJ French ELEMENTS DE BASE DU COMPRESSEUR D AIR Les compresseurs d air sans huile sont lubrifi s lusine et ne requi rent aucun huilage Les composants de base du compresseur d air sont le moteur lectrique la pompe le panneau de commande num rique et le r servoir Le moteur lectrique A actionne la pompe Le moteur lectrique est quip d un limiteur de surcharge r en clenchement automatique Si le moteur surchauffe le limiteur coupe l alimentation pour viter d endommager le moteur Lorsque le moteur est suffisamment refroidi il red marre automatiquement La pompe B comprime l air Le panneau de commande num rique voir D comporte le bouton on off Marche Arr t E le bouton de r glage de la pression hausse F le bouton de r glage de la pression baisse G l indicateur de pression du r servoir H le bou ton de pression du r servoir I le bouton de r glage des param tres de pression par d faut 90 PSI J le bouton de r glage des param tres de pression par d faut 40 PSI K et une fen tre d affichage sur cran cristaux liquides L Lorsque l appareil utilise de l air comprim et lorsque le niveau de pression du r servoir tombe la pression de d marrage le tableau de commande fait red marrer automa tiquement le moteur sans avertissement et la pompe recom mence comprimer l air
54. tent un entretien p riodique Les composants num r s ci dessous doivent tre inspect s r quli rement e Fench VIDANGE DU R SERVOIR REED la condensation se forme dans le r servoir Pour viter la formation gt de corrosion depuis l int rieur du r servoir cette condensation doit tre vacu e la fin de chaque journ e de travail Veillez porter des lunettes de protection Lib rez la pression d air dans le circuit et ouvrez le robinet de purge en bas du r servoir pour vidanger Voir B et D aux pages 14 15 et 16 REMARQUE Dans les climats froids purger le r servoir apr s chaque utilisation afin de r duire les probl mes de gel d eau de condensation 200 2614 Em V RIFICATION DE LA SOUPAPE DE D CHARGE Tirez chaque jour sur la soupape de d charge pour vous assurer qu elle fonctionne correctement et liminer toutes les obstructions ventuelles D ESSAI D TANCH IT Assurez vous que tous les raccords sont serr s Le rendement de votre compresseur peut tre r duit de mani re significative en pr sence d une petite fuite d air dans les tuyaux flexibles ou les raccords de tuyauterie Si vous sus de la zone Si des bulles apparaissent r parez ou remplacez le composant d fectueux Ne serrez pas trop De ENTREPOSAGE Avant d entreposer le compresseur pour une p riode pro long e utilisez une soufflette pour nettoyer toute la poussi re et tous les d bris du compresseur D
55. ter attention ces sections CEE DANGER POTENTIEL POUVANT ENTRA NER DE GRAVES BLESSURES OU LA MORT A BEEN DANGER POUVANT CAUSER DES BLESSURES GRAVES VOIRE MORTELLES EAN DANGER POUVANT CAUSER DES BLESSURES MOYENNEMENT GRAVES OU L ENDOMMAGEMENT DE L APPAREIL A Wena 1 RISQUES D INCENDIE OU D EXPLOSION Ne jamais vaporiser de liquides inflammables dans un endroit confin Il est normal que le moteur et le manostat produisent des tincelles pendant le fonctionnement Si les tincelles entrent en contact avec les vapeurs d essence ou d autres solvants ces vapeurs peuvent s enflammer et causer un incendie ou une explosion Utilisez toujours le E compresseur dans une zone bien a r e Ne fumez y pas quand vous pulv risez Ne pulv risez pas en pr sence d tincelles ou d flammes Placez le compresseur aussi loin que possible de la zone de pulv risation 2 RISQUE D ECLATEMENT La rouille peut affaiblir le r servoir Purger l eau de condensation du r servoir apr s chaque usage afin de r duire la corrosion Si une fuite est d cel e remplacer le r servoir imm diatement Ne soudez pas ne percez pas ou ne modifiez pas le r servoir d air de ce compresseur La soudure ou des modifications sur le r servoir du compresseur d air peut sensiblement alt rer sa solidit et causer des conditions d utilisation extr mement dangereuses La soudure ou la modification quelconque du r servoir entra nera l annulatio
56. tiva intente utilizar una manguera de aire m s De RALLONGES Continu Utilisez seulement une rallonge 3 fils munie d une prise de terre 3 lames et une prise de courant 3 fentes dans laquelle la prise peut tre branch e Veillez ce que la rallonge que vous allez utiliser soit en bon tat Une rallonge de dimension inf rieure celle pr conis e causera une baisse de tension sur la ligne qui se soldera par une perte de puissance et une surchauffe Plus le calibre est petit plus la rallonge doit tre grosse Em INSTRUCTIONS DE MISE LA TERRE Ce produit doit tre mis la terre En cas de court circuit lec trique la mise la terre r duit les risques de d charges lectriques en fournissant un fil par lequel le courant lectrique peut s chap per Ce produit est quip d un c ble d alimentation muni d un fil de terre et d une fiche de terre appropri e Cette fiche doit tre branch e sur une prise de courant qui t mise la terre et install e conform ment toutes les normes et d crets locaux A DANGER L installation incorrecte de la fiche de terre risque de provoquer des d charges lectriques En cas de remplacement n cessaire du c ble ou de la fiche ne branchez pas le fil de terre ee sur l une des lames plate Le fil de terre est recouvert d une gaine d isolement verte avec ou sans rayures jaunes Ce produit est concu pour fonctionner sur un circuit d une ten sion nominale de
57. tivit de ce genre annule toutes les garanties Ils ont t pr r gl s en usine pour la pression maximale de cet appareil Si le tableau de commande ou la soupape de s ret est alt r e cela pourrait mener des blessures et ou des dommages la propri t RISQUE D CLATEMENT Nutilisez pas de tuyaux en plastique ou en PVC pour l air comprim Utilisez uniquement des tuyaux et des raccords en acier galvanis pour le circuit de distribution de l air comprim RISQUE AUDITIF Porter toujours des protecteurs d oreilles en utilisant un compresseur d air Dans le cas contraire il y a risque de perte d audition RISQUE RESPIRATOIRE Ne jamais inhaler l air com ration Le cordon de secteur sur ce produit contient le fil un produit chimique connu de l tat de la Californie pour causer le cancer et la naissance d serte ou l autre mal reproducteur Mains de lavage apr s manipula tion Si vous transportez le compresseur fixez le bien Avant de le transporter il faut d abord d pressuriser le r servoir Prot gez le tuyau d air contre les risques d endommagement et de perforation Inspectez le chaque semaine pour d celer toute trace de faiblesse ou d usure et remplacez le au besoin Pour r duire les risques de d charge lectrique prot gez l appareil de la pluie Entreposez le l int rieur Ne faites jamais fonctionner le compresseur si le cordon ou la fiche est endommag e Apportez l quipe
58. u s se guardar como la nueva presi n predeterminada para este bot n Configuraci n ajustable de la presi n ajuste por omisi n a 90 PSI Al presionar este bot n en el panel de control digital se configurar la presi n del tanque a una cantidad predeterminada de PSI el ajuste por omisi n es de 90 PSI Para modificar esta configuraci n predeterminada de PSI configure la presi n deseada utilizando los botones o Presione el bot n 2 durante 5 segundos La presi n mostrada parpadear 3 veces y despu s se guardar como la nueva presi n predeterminada para este bot n Pantalla LCD Esta pantalla indicar autom ticamente la presi n de salida regulada cuando la unidad est encendida En la pantalla aparecer n el icono de encendido apagado on off y el icono de la herramienta La pantalla mostrar autom ticamente la presi n del tanque cuando la unidad est apagada pero contin e conectada a la corriente en caso de que la presi n no sea cero La barra al lado derecho de la pantalla LCD es un indicador visual de la P presi n del tanque Cuando la barra llegue hasta la parte superior la pre si n est en 155 PSI y el compresor se apagar Cuando la barra llegue hasta la parte inferior la presi n est en 125 PSI y el compresor se encender DIGT CA PLUS A EUX Nunca exceda la presi n m xima de funcionamien to de la herramienta Presione el bot n para incrementar la pre si n
59. ula de alivio 17 V lvula de alivio de la presi n 11 Detecci n de fugas 17 Salida de la linea de aire 11 Almacenamiento 17 REQUERIMIENTOS DE ALIMENTACI N EL CTRICA 13 INTERVALOS DE SERVICIO 18 Cableado el ctrico 13 CUADRO DE DETECCI N DE FALLOS 21 22 Cordones prolongadores 13 GLOSARIO DE T RMINOS 23 Instrucciones de conexi n a tierra 13 2 200 2614 english SAFETY GUIDELINES The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the following symbols Please read the manual and pay attention to these sections A DANGER A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE A MENN A POTENTIAL HAZARD THAT COULD CAUSE SERIOUS INJURY OR LOSS OF LIFE A e UE A POTENTIAL HAZARD THAT MAY CAUSE MODERATE INJURY OR DAMAGE TO EQUIPMENT A LA 1 M ya e E x 5 e RISK OF FIRE OR EXPLOSION Never spray flammable liquids in a confined area lt is normal for the motor and pressure switch to produce sparks while operating If sparks come into contact with vapors from gasoline or other solvents they may ignite causing fire or explosion Always operate the compressor in a well ventilated area Do not s
60. urarse de que est operando correctamente y para eliminar cualquier obstrucci n posible de la misma sois DETECCI N DE FUGAS Compruebe que todas las conexiones est n ajustadas Una peque a fuga en cualquiera de las mangueras o tuber a reducir de manera substancial el rendimiento de su compre sor de aire Si sospecha la existencia de una fuga roc e una peque a cantidad de agua jabonosa alrededor de la zona con una botella rociadora Si aparecen burbujas selle y ajuste nuevamente la conexi n No ajuste demasiado RDA ALMACENAMIENTO Antes de almacenar el compresor durante periodos pro longados use un soplete de aire para limpiar todo el polvo y suciedad del compresor Desconecte el cord n el ctrico enroll ndolo Tire de la v lvula de alivio de la presi n para lib erar toda la presi n del tanque Elimine toda la humedad del tanque Cubra toda la unidad para protegerla de la humedad y del polvo 17 english SERVICE INTERVAL Perform the following maintenance at the intervals indicated below Operate the pressure relief valve Daily Draln tank ss sus stef ad a ia taie a Daily De ENTRETIEN P RIODIQUE Effectuez l entretien suivant aux intervalles indiqu s ci dessous Faites fonctionner les soupapes de d charge Chaque jour Vidangez le r servoir Chaque jour Es INTERVALOS D
61. urer une ventilation correcte pour le refroidissement le compresseur doit tre plac une distance minimum de 31 cm 12 pouces du mur le plus proche dans une zone bien a r e 11 gt 12 prim d un compresseur Il ne convient pas la respi RISQUE DE BRULURE Les temp ratures lev es sont produites par la pompe et la tubulure Pour viter toute br lure ou d autres blessures NE TOUCHEZ S la pompe le distributeur ou le tube de transfert tandis que la pompe fonctionne Laissez les refroidir avant de les manipuler ou de proc der leur entretien Ne laissez jamais les enfants s approcher du compresseur RISQUE RESPIRATOIRE Veillez lire toutes les tiquettes quand vous pulv risez de la peinture ou des mat riaux toxiques et suivez les consignes de s curit Utilisez un masque gaz si vous risquez d inhaler le produit pulv ris Lisez toutes les instructions et veillez ce que le masque gaz assure votre protection RISQUE DE BLESSURE AUX YEUX Porter toujours des lunettes de s curit homologu es ANSI Z87 1 lors de l utilisation d un compresseur d air Ne dirigez jamais une buse ou un pulv risateur vers quelqu un ou une quelconque partie du corps Ce mat riel peut causer des blessures graves si le produit vaporis p n tre dans la peau RISQUE D ECLATEMENT N alt rez pas le tableau de commande et n ajustez pas la soupape de s ret pour quelque raison que ce soit car toute ac
62. y el bot n para disminuirla q ES HA 1 e Modifique los ajustes de la configuraci n de presi n de PSI libras por pulgada cuadrada a BARES Presione el bot n encendido apagado para encender la unidad Presione los botones de encendido apagado y de presi n del tanque durante 5 segundos para ingresar el modo en que desea que aparezca la configuraci n Presione el bot n para incrementar la presi n para seleccionar el modo PSI Presione el bot n para disminuir la presi n para selec cionar el modo BARES Espere durante 5 segundos para que la unidad memorice la configu raci n seleccionada y se apague Reinicie la unidad para verificar la presi n de operaci n de la unidad en la configuraci n seleccionada 10 200 2614 COMPRESSOR CONTROLS Y COMMANDES DU COMPRESSEUR Y CONTROLES DEL COM PRESOR Engish PRESSURE RELIEF VALVE Figure 1 Figura 1 If the control board does not shut down the motor when the pressure reaches the preset level this valve will pop open automatically to prevent over pressurization To operate manu ally pull the ring on the valve to relieve air pressure in the tank see Figure 1 A EAU Risk of injury Before transporting or e performing any type of service to the unit always shut off the compressor remove the plug from the K outlet and bleed all the pressure from the system through the outlet hose or by pulling the pressure relief valve rin
Download Pdf Manuals
Related Search
Related Contents
Divar XF, el Videograbador Digital Híbrido it aliano english français deutsch it aliano english français deutsch INSTALLATION & OPERATION GUIDE Lincoln Electric pmn User's Manual MY WEIGH KD-7000 - mancelboutique.net Au sommaire de votre guide Représentants du personnel : Au menu U-WAVE-R WH25 OPERATING INSTRUCTIONS Scheda tecnica Alfea Extensa Duo Copyright © All rights reserved.
Failed to retrieve file