Home

Philips VSS9451 User's Manual

image

Contents

1. 50 Hz b Environmental Temperature range ececeeeseeees operating 10 to 40 C PE POENA IEAI TT sess KREIEREN N E storage 25 to 70 C PUA reoi ese 20 95 non condensing Subject to modification 3138 105 2828 1 Placering Ventilation VARNING FORSAKRA DIG OM ATT HUVUDBRYTARE OCH UTTAG AR LATATKOMLIGA NAR DU STALLER DIN UTRUSTNING PAPLATS Placering ventilation ADVARSEL S RG VED PLACERINGEN FOR AT NETLEDNINGENS STIK OG STIKKONTAKTER NEMT La tapa posterior unicamente debe retirarla un T cnico de Servicio La puesta en funcionamiento del aparato sin tapa posterior es peligros simo Paikka llmankierto VAROITUS SIJOITA LAITE SITEN ETTA VERKKOJOHTO VOIDAAN TARVITTAESSA HELPOSTI IRROTTAA PISTORASIASTA Plassering Ventilasjon ADVARSEL N R DETTE UTSTYRET PLASSERES M DU PASSE PA AT KONTAKTENE FOR STOMTILFORSEL ER LETTEANA DI Printed in Taiwan 0693 1
2. Philips Consumer Electronics Video Colour Monitor VSS9451 lI II pee at a oe te Ir E a nn di U re id i Se Ye a x Ar eee k eos EE PEE ee o lll o 000 6 Instructions for use CF Mode d emploi D Bedienungsanleitung QL Gebruiksaanwijzing CE Instrucciones de manejo OD Instruzzioni per l uso PHILIPS BS p EEA ini page 3 TRINCA essen page 6 D CU SG sags coda Seite 8 aD Nederlands ooocconnoccnconoconococaconannnanonannenanenarennos pagina 10 GEILE ESPAINOL aa pagina 12 Sn A ee pagina 14 Bescheinigung des Herstellers Importeurs Hiermit wird bescheinigt da der VSS9451 00T Gerat Typ Bezeichnung in bereinstimmung mit den Bestimmungen der BMPT AmtsbIVfg243 1991 funk entst rt ist Der vorschriftsm ige Betrieb mancher Ger te z B MeBsender kann allerdings gewissen Einschr nkungen unierliegen Beachten Sie deshalb die Hinweise in der Bedienungs anleitung Dem Bundesamt f r die Zulassungen in der Telekommunikation wurde das In verkehrbringen dieses Ger tes angezeigt und die Berechtigung zur berpr fung der Serie auf die Einhaltung der Bestimmungen einger umt Philips GmBH Hamburg oe OR RETTET RE ET eee ane een Name und Anschrift des Herstellers Importeurs Volume Saturation INSTRUCTIONS FOR USE NA Contrast Brightness Horizontal Shift 99a CONTROLS 1 Volume 1 To adjust the volum
3. ation as this could obstruct the required ventilation When dust accumulates on the screen surface clean with a soft cloth Do not use alcohol or ammonia based liquid to clean the monitor If necessary clean with a slightly damp cloth Disconnect the monitor from the mains supply before cleaning Unplug this unit from the wall socket and refer servicing to qualified service personnel under the following conditions when the mains lead is frayed or the plug is damaged if liquid has been spilled into the unit if the unit does not operate normally following the operating instructions if the unit has been dropped or the cabinet has been damaged when the unit exhibits a distinct change in performance Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Always refer servicing to qualified service personnel WARNINGS To prevent fire or shock hazard do not expose this monitor to rain or moisture Dangerous high voltages are present inside the unit Do not remove the back cover of the cabinet When servicing the monitor contact qualified service personnel Never try to service it yourself Improper operations in particular alteration of high voltage or changing the type of tube may result in x ray emission of considerable dose A unit altered in such a way no longer meets the standards of certification and mus
4. e 2 Hue w a NTSC versions only To adjust the hue 3 Picture controls To optimize the picture The centre click position of each control is its standard setting Saturation To adjust the colour density of the picture Contrast O To adjust the picture contrast Brightness To adjust the picture brightness 4 Horizontal shift gt Screwdriver adjustment to center the picture The factory dafault is optimized for standard video signals 5 Power Switching the power on and off FITTING A MAINS PLUG U K only This apparatus is fitted with an approved moulded 13 Amp plug To change a fuse in this type of plug proceed as follows 1 Remove fuse cover and fuse 2 Insert new fuse which should be a BS1362 5A A S T A or BSl approved type 3 Refit the fuse cover If the fitted plug is not suitable for your socket outlets it should be cut off and an appropriate plug fitted in its place If the mains plug contains a fuse this should have a value of 5A If a plug without a fuse is used the fuse at the distribution board should not be greater than 5A NOTE The severed plug must be disposed of to avoid the possibility of an electric shock should it be inserted into a 13A socket elsewhere HOW TO CONNECT A PLUG The wires in the mains lead are coloured in accordance with the following code BLUE NEUTRAL N BROWN LIVE L GREEN YELLOW EARTH E 7 The GREEN AND YELLOW w
5. ire must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN AND YELLOW 2 The BLUE wire must be connected to the terminal which is marked with the letter N or coloured BLACK 3 The BROWN wire must be connected to the terminal which is marked with the letter L or coloured RED Before replacing the plug cover make certain that the cord grip is clamped over the sheath of the lead not simply over the three wires A mt rr tr ie er ee INSTRUCTIONS FOR USE PRECAUTIONS In order to prevent any fatal accidents caused by misoperation or mishandling of the monitor be fully aware of all the following precautions e Only use the power source specified on the rating label located on the of the cabinet e When not using this unit for a long period of time or when cleaning it be sure to disconnect the mains plug from the mains supply Do not allow anything to rest on the mains lead Do not locate this unit where people will tread on the cord Do not overload wall sockets or mains leads as this may result in fire or electric shock Avoid using this unit under the following conditions in extremely hot cold or humid places in dusty places near appliances generating strong magnetic fields in places subject to direct sunlight in badly ventilated places Do not cover the ventilation slots while in oper
6. t therefore no longer be operated INSTALLATION e Before installing this monitor please refer to the instructions for use of your camera or VCR to make sure if these equipments require any change of setting POSITIONING VENTILATION e When positioning this equipment ensure that the mains plug and socket are easily accessible e Do not place the monitor near a heat source e To prevent overheating ensure that the ventilation openings of the monitor are not covered MAINS CONNECTIONS Before connecting the equipment to the mains of the building installation the protective earth lead of the building must be checked for its proper functioning e The monitor is supplied with a 2 m long mains lead terminated with a 2 pole Europlug with safety earth connections In some countries it will be necessary to replace this plug with one of a locally standard type The wiring to the plug must be as follows brown live in the U K marked L or coloured red blue neutral in the U K marked N or coloured black yellow green earth in the U K marked E or or coloured yellow and green VIDEO AUDIO INPUT e Be sure to disconnect the mains lead from the mains socket before connecting the other equipment e Also refer to the instructions for use of the equipment to be connected CONNECTIONS 1 POWER e Connect to the mains socket using the mains lead supplied 2 CVBS Input socket for composite
7. video signal e Connect to e g a video camera VCR or video control panel Output socket for signal loopthrough to other equipment e Connect to e g a second monitor or VCR 3 Audio Input socket for audio signal e Connect to e g an audio control panel or amplifier Output socket for signal loopthrough to other equipment e Connect to e g a second monitor or VCR 4 75 Q High Signal line termination switch for CVBS in outputs e Switch to 75 Q when there is only input signal e Switch to High in case of loopthrough operation 5 Y C Input Input socket for luminance Y and chrominance C signal This input can be used in applications where high resolution is required Socket and signals according to S VHS standard 1 GND luminance 2 GND chrominance 3 LUMINANCE signal 4 CHROMINANCE signal 6 Notch Off To avoid cross colour interference when using the CVBS input 2 In high resolution Y C operation this switch should preferably be set to off NOTE Never use the CVBS 2 and the Y C 5 connection at the same time INSTRUCTIONS FOR USE TECHNICAL DATA a Electrical Picture TUDO sun 14 90 deflection 0 42 mm Resolution gt 520 TVL bandwith 6 5 MHz Signal inputs A aeons 1 Vpp into 75 Q or bridging BNC ias 1 Vpp 300MVpp into 75 Q Hosiden MINI DIN AU oda 177mVeff into 10 KQ Iy Standard nase PAL 625 lines 50 Hz Power supply cocccccoocccnnonons mains voltage 198 264 V AC

Download Pdf Manuals

image

Related Search

Related Contents

User Manual VS-112i 2 埠卡式視訊分配器  Olympia PS 515.4CCD  User's Manual - webclienti.it  User Manual    操縦装置専用ツール  OPERATING INSTRUCTIONS  小形ギヤモータ  Mode d`emploi  kv-s1025c  

Copyright © All rights reserved.
Failed to retrieve file