Home

Pelco MC3700 User's Manual

image

Contents

1. Figure 4 Power Supply Connections To connect the camera power and video 1 Remove the cosmetic trim ring from the camera refer to Figure 1 Thread cabling through the rear cover 2 Connectthe power cable to the two pin power connector on the back of the camera using the terminal block connector provided Refer to Table A for the recommend wire gauge and wiring distances 3 Connect a video cable to the SIGNAL OUT connector BNC on the back of the camera Refer to Table B for the type of video coaxial cable to use 4 Reattach the trim ring to the back of the camera 8 Pelco Manual C1987M 6 02 AC Operation Only If you are wiring more than one camera to the same transformer connect one side of the transformer to the same terminal on all cameras and connect the other side of the transformer to the remaining terminal on all cameras Failure to connect all of the cameras the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras Table A Recommended Wire Gauge and Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Wire Gauge Total 20 18 16 14 12 10 vA 0 5 mm 1 0 mm 1 5 mm 2 5 mm 4 0mm 6 0 mm 10 283 451 716 1142 1811 2880 86 137
2. BNC VIDEO CONNECTOR LED LENS CONNECTOR DIP SWITCHES COVER REMOVED Figure 1 Camera Layout NOTE The cosmetic trim ring conceals the LED light for more discreet surveillance operations The trim ring also hides the power connectors and protects the DIP switches INSTALLATION Lens Mounting The MC3700 Series camera can use fixed iris manual iris auto iris or direct drive lenses Cameras are factory set for CS mount lenses but easily adjusted for C mount lenses 1 C Mount Lens Only Loosen the two back focus locking screws Rotate the back focus adjustment ring fully counterclockwise before installing the C mount lens refer to the section on Back Focus Adjustment 2 Remove the cosmetic trim ring from the back of the camera refer to Figure 1 Set the lens mode selector switch on the side of the camera to AIV auto iris video drive lens or AID auto iris DC drive lens Refer to the Switch Settings section Switch setting is determined by the type of lens used 3 Screw the lens onto the lens mount Be careful to prevent dust from entering the space between the lens and the CCD element If necessary use clean compressed air to remove any foreign matter 4 Thread the lens cable through the cosmetic trim ring 5 Connect the auto iris lens to the 4 pin iris drive connector located on the side of the camera Pin connections for the iris drive connector are as follows 6 Pelco Manual C1987M 6 02 3 4 PIN
3. 218 348 551 877 EXAMPLE A camera that requires 10 vA and is installed 283 feet 86 m from the transformer would require a minimum wire gauge of 20 AWG NOTE Distances are calculated in feet values in parentheses are meters Table B Video Coaxial Cable Requirements Cable Type Maximum Distance RG59 U 750 ft 229 m RG6 U 1 000 ft 305 m RG11 U 1 500 ft 457 m Minimum cable requirements 75 ohms impedance All copper center conductor All copper braided shield with 95 braid coverage Pelco Manual C1987M 6 02 9 LENS SETUP AND FOCUS PROCEDURES Video Drive Auto Iris Lens When a video drive auto iris lens is used the lens mode selector switch must be set to AIV Switch the ESC and AGC OFF Refer to the lens instructions and adjust the lens for the optimum picture video output level of 1V peak to peak Switch the AGC ON To focus fully open the iris by covering the lens with a suitable neutral density ND filter If the viewed scene is 6 5 feet 2 m away or farther set the lens focus to infinity far Use the back fo cus adjustment ring refer to the Zack Focus Adjustment section and focus on the selected scene Remove the ND filter and set the lens focus as required Direct Drive DC Auto Iris Lens When a direct drive lens is used the lens mode selector switch must be set to AID Switch the ESC and AGC OFF Use an appropriate screwdriver to turn the lens level
4. DC AID AUTO IRIS LENS VIDEO AIV AUTO IRIS LENS 1 Control coil negative Not used 2 Control coil positive Lens positive supply 1 2 3 Drive coil positive Video drive signal 4 Ground Drive coil negative Figure 2 AID AIV Lens Connector Camera Mounting Use a standard 1 4 20 screw provided with a maximum thread length of 3 8 inch 10 mm for top or bottom cam era mounting The mount adapter may be fitted to the top or bottom of the camera The camera is shipped with the mount adapter located on the top of the camera To change the mount adapter position 9 Remove the four screws from the mount adapter located on the top of the camera e Remove the trim cover from the bottom of the camera by prying it loose Place the trim cover on the top of the camera where the mount adapter was removed Press into place e Install the mount adapter to the bottom of the camera Secure with the four screws removed in step 1 Figure 3 Camera Mounting Pelco Manual C1987M 602 7 POWER AND VIDEO CONNECTIONS MC3700 Series camera is designed to operate from a 12 VDC or 24 VAC power supply The power supply con nections are shown in Figure 4 The LED on the back panel of the camera indicates that power is connected Use only a Class 2 isolated power supply Power consumption is less than 5 watts CLASS 2 ISOLATED POWER SUPPLY CLASS 2 ISOLATED POWER SUPPLY 12 VDC
5. potentiometer refer to Figure 1 fully clockwise Next slowly adjust the potentiometer counterclockwise until the optimum picture is obtained video output level of 1V peak to peak Switch the AGC ON To focus fully open the iris by covering the lens with a suitable neutral density ND filter Select the scene to be viewed If the viewed scene is 6 5 feet 2 m away or farther set the lens fo cus to infinity far Use the back focus adjustment ring refer to the Back Focus Adjustment section and focus on the selected scene Remove the ND filter and set the lens focus as required Fixed Lens Set the ESC switch and AGC switch to ON To focus set the lens focus to infinity and view an image greater than 6 5 feet 2 m away Focus the image with the back focus adjustment ring refer to the Back Focus Adjustment section Set the lens focus as required Manual Iris Lens Set the ESC switch and AGC switch to ON To focus open the iris fully and set the lens focus to infinity View an image greater than 6 5 feet 2 m away Focus the image with the back focus adjustment ring refer to the Back Focus Adjust mentsection Adjust the lens focus and set the iris for the best picture quality The largest aperture gives the best light sensitivity the smallest aperture the greatest depth of field Zoom Lens Set the lens focus to infinity far and fully open the iris by covering the lens with a suitable neutral density ND filter Zoom out to the w
6. 15 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on Pelco manufactured cameras CC3500 CC3600 CC3700 and MC3500 MC3600 Series two years on all other cameras Three years on Genex Series multiplexers server and keyboard Two years on cameras and all standard motorized or fixed focal length lenses Two years on Legacy Camclosure Camera Systems CM6700 CM6800 CM8500 CM9500 CM9740 CM9760 Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including when used in continuous motion applications Two years on Esprit and WW5700 series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are n
7. PELLO Installation Operation MC3700 Series Monochrome Camera C1987M 6 02 G US LISTED Pelco World Headquarters 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 2 Pelco Manual C1987M 6 02 CONTENTS IMPORTANT SAFEGUARDS AND WARNINGS Regulatory Notices DESCRIPTION Models CAMERA EAYOUT te ai aaa 6 INSTALLATION ue E 6 Lens Mounting Camera Mounting POWER AND VIDEO CONNEGTIONS u u n rte rte tt tei erede d aha 8 LENS SETUP AND FOCUS PROCEDURES akiro aee er a ea E K ttes 10 BACKFOGUS ADJUSTMENT ciale iaia 11 SWITCH SETTINGS u t alia iii 12 CAMERA SYNCHRONIZATION ta 14 SPECIFICATIONS ni aaa ii aa 15 WARRANTY AND RETURN INFORMATION eene ntes 16 LIST OF ILLUSTRATIONS Figure 1 Camera Layout Figure 2 AID AIV Lens Connector Figure 3 Camera Mounting Figure 4 Power Supply Connections Figure 5 Back Focus Adjustment Figure 6 Switch Settings Figures7 BLC Setup SwitChes ici eee e aede tene eet tette eR D RR cete LIST OF TABLES Table A Recommended Wire Gauge and Wiring Distances Table B Video Coaxial Cable Requirements Pelco Manual C1987M 602 3 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should be done o
8. ed to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below f you are located within the continental U S Alaska Hawaii or Puerto Rico fyou are located outside the continental U S Alaska Hawaii or Puerto Rico Service Department Intermediate Consignee Ultimate Consignee Pelco American Overseas Air Freight Pelco 3500 Pelco Way 320 Beach Road 3500 Pelco Way Clovis CA 93612 5699 Burlingame CA 94010 Clovis CA 93612 5699 USA USA 0 Pelco the Pelco logo Spectra Genex and Legacy are registered trademarks of Pelco TM Esprit and Camclosure are trademarks of Pelco TM HyperHAD and EXview HAD CCD are trademarks of the Sony Corporation Copyright 2002 Pelco All rights reserved REVISION HISTORY Manual Date Comments C1987M 3 02 Original version 6 02 Revised Horizontal Resolution 16 Pelco Manual C1987M 6 02
9. h switches 8 and 9 as an aid to setting the Back 1m0 OFF light Compensation feature Pelco Manual C1987M 6 02 13 CAMERA SYNCHRONIZATION When using one AC power supply in a multi camera system a brief vertical roll may occur on the monitor each time a camera view is switched To eliminate vertical roll adjust the phase control to synchronize line lock the cameras to one another The synchronization switch DIP switch 10 for each camera must be set to LL Use the potentiometer located on the side of the camera to make adjustments It may be necessary to have two people in communication when synchronizing the cameras one person at the camera and another person at the monitor to observe the vertical roll and the effect of any adjustments made at the camera To synchronize the cameras do the following 1 Choose a reference camera to which all other cameras will be phased 2 Selecta camera and synchronize it to the reference camera by turning the phase adjustment control clock wise and or counterclockwise 3 Each time an adjustment is made switch back and forth between the camera you are adjusting and the refer ence camera Repeat this process as many times as necessary until the roll between the cameras is no longer noticeable 4 Adjustthe phase of all other cameras by repeating steps 2 through 3 Always adjust to the reference camera selected in step 1 NOTE The preferred method for camera phase adjustment is to use a dual
10. idest field of vision and view a distant object Adjust the back focus adjustment ring until the object is in focus refer to the Back Focus Adjustment section Next zoom fully in and adjust the lens focus until the object is again focused Repeat these steps until the full zoom range may be viewed with the minimum loss of focus 10 Pelco Manual C1987M 6 02 BACK FOCUS ADJUSTMENT The back focus adjustment is located at the front of the camera and is accessible from either side of the case To adjust the back focus 1 Loosen the two back focus locking screws one on each side 2 Turn the back focus ring a Clockwise Moves the CCD sensor assembly towards the back of the lens b Counterclockwise Moves the CCD sensor away from the lens 3 When the back focus adjustment is satisfactory tighten the locking screws Do not over turn or force the back focus adjustment ring S gao count BACK FOCUS ADJUSTMENT BACK FOCUS LOCKING SCREW ADJUSTMENT RING Figure 5 Back Focus Adjustment Pelco Manual C1987M 6 02 11 SWITCH SETTINGS m 1 Figure 6 Switch Settings Defaults NOTE Under most conditions no setting of switches will be required Please read the details of each switch before making any adjustments LL INT Synchronization Selection Switch Setting 10 Locks the frame rate to the power supply frequency Eliminates vertical roll caused by multiple cameras connected to the same switchi
11. manual iris lenses AGC Default setting Enables the AGC mode 58H AGC OFF Disables the AGC mode 5 0 OFF ESC ON ESC OFF Electronic Sensitivity Control Switch Setting 4 The ESC feature compensates for an excessive light level by automatically adjusting shutter speed Selecting ESC Iris disables manual shutter speed selection The ESC Iris setting must not be used when the camera is set to Flickerless mode Following are the ESC switch settings ON Default setting Enables the Electronic Sensitivity Control mode 4UBM ON OFF Disables the Electric Iris mode 4 OFF BLC Backlight Compensation Switch Settings 2 and 3 The BLC Backlight Compensation feature compensates for backlit scenes by enhancing objects in the center of the scene that would previously have been in silhouette BLC will only function with a manual iris lens when the Electronic Sensitivity Control feature is switched on For direct drive and auto iris lenses BLC will still func tion even though the Electronic Sensitivity Control feature is switched off Following are the BLC switch settings ON Enables the BLC mode OFF Default setting Disables the BLC mode ms E E o II OFF Il BLC Active Zone The area used to calculate picture exposure Figure 7 BLC Setup Switches WND ON WND OFF BLC Setup Window Switch Setting 1 This switch allows you to turn the BLC window video overlay on or off 1088 WND The overlay is used in conjunction wit
12. ng device Each camera output is syn chronized to the frequency of the power supply Set the camera synchronization mode to one of the following LL Default setting Line locks frame rate of cameras omn LL INT Disables line lock use with DC power or noisy AC power 10088 INT Lens Mode Selector AIV AID Switch Switch Setting 9 The AIV AID switch setting is determined by the type of lens used AIV Video drive auto iris lens 9 O AIV AID Default setting Direct drive lens 9 BI AID Sharpness Normal Sharpness Sharp Switch Setting 8 This switch can be used to enhance detail in the image NOR Default setting Normal picture sharpness 8 Di NOR SHP Sharpens the edges of the objects in the picture 8 mO SHP Gamma LO Gamma HI Switch Setting 7 Set the Gamma level to one of the following NOR Default setting Increases visibility in the dark areas of the picture 7WI NOR LIN Linear response increases overall contrast 7088 LIN AGC HI AGC STD Switch Setting 6 This switch sets the AGC Automatic Gain Control feature of the camera Two settings are available HI Applies more gain to the video signal and slightly increasing the noise in the picture som HI STD Default setting Applies normal AGC gain to the picture Use in most applications 680 STD 12 Pelco Manual C1987M 6 02 AGC OFF AGC ON Switch Setting 5 Automatically adjusts the image to compensate for low light levels when using fixed or
13. nly by qualified service and installation personnel 2 Installation shall be done in accordance with all local and national electrical and mechanical codes utilizing only approved materials 3 Use only installation methods and materials capable of supporting four times the maximum specified load 4 Useonly UL listed class 2 power supply 5 To prevent fire or shock hazard do not expose this appliance to rain or moisture DD AI Lens Connector The maximum load for a direct drive lens must not exceed 25 mA The maximum load for an auto iris lens must not exceed 50 mA REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a resi dential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between
14. ot covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed he price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide he following information Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts return
15. the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device many not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada 4 Pelco Manual C1987M 6 02 DESCRIPTION The MC3700 Series monochrome video camera is compact with a 1 3 inch CCD imager The camera has a direct drive auto iris lens connector and adjustable back focus and accepts C and CS lenses Models MC37008 2 Standard resolution 380 TV lines SuperHAD CCD 0 08 lux 50 IRE f1 2 EIA MC3700S 2X Standard resolution 380 TV lines SuperHAD CCD 0 08 lux 50 IRE f1 2 CCIR Pelco Manual C1987M 6 02 5 CAMERA LAYOUT BACK FOCUS ADJUSTMENT LOCKING MOUNT ADAPTER PHASE ADJUSTMENT LENS LEVEL ADJUSTMENT ug POWER CONNECTOR COSMETIC TRIM lt RING N Z BACK FOCUS ADJUSTMENT RING
16. trace oscilloscope to align the vertical sync pulses of the reference camera to the selected camera s 14 Pelco Manual C1987M 6 02 SPECIFICATIONS GENERAL CCD Sensor Synchronization System Horizontal Resolution Iris Control Minimum Illumination Signal to Noise Ratio Gain Control Vertical Phase Automatic Gain Control Backlight Compensation Scanning System Auto Iris Lens Type Video Output Iris Control Range ELECTRICAL Power Requirements Power Connector Video Connector Lens Jack Power Consumption MECHANICAL Lens Mount Camera Mount ENVIRONMENTAL Operating Temperature Storage Temperature PHYSICAL Physical Dimensions Weight without lens 1 3 inch AC line lock or internal oscillator 380 TV lines Electronic passive 0 08 lux 50 IRE f1 2 52 dB AGC Off Automatic Adjustable 0 120 Selectable by DIP switch setting Selectable by DIP switch setting 525 lines 2 1 interlace DC video control 1 Vp p 75 ohms 1 60 1 100 000 second 11 40 VDC or 14 30 VAC 2 pin terminal strip push in type BNC 4 pin connector miniature square Less than 4 watts C CS mount adjustable Use 1 4 20 screw top or bottom of camera housing 14 to 122 F 10 to 50 C 14 to 158 F 10 to 70 C 2 48 W x 2 67 H x 4 33 D inches 6 3 x 6 8 x 11 cm 0 77 lb 0 35 kg Design and product specifications subject to change without notice Pelco Manual C1987M 6 02