1. for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number sales order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product that does not fall under the warranty co
2. 500 Series enclosures Spectra IV products including Spectra IV IP Camclosure Series IS ICS IP integrated camera systems DX Series digital video recorders DVR5100 Series digital video recorders Digital Sentry Series hardware products DVX Series digital video recorders and NVR300 Series network video recorders Endura Series distributed network based video products Genex Series products multiplexers server and keyboard PMCL200 300 400 Series LCD monitors Two years Standard varifocal fixed focal and motorized zoom lenses DF5 DF8 Series fixed dome products Legacy Series integrated positioning systems Spectra III Spectra Mini Spectra Mini IP Esprit ExSite and PS20 scanners including when used in continuous motion applications Esprit Ti and 112500 Series thermal imaging products Esprit and WW5700 Series window wiper excluding wiper blades CM6700 CM6800 CM9700 Series matrix Digital Light Processing DLP displays except lamp and color wheel The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty Intelli M elDC controllers One year Video cassette recorders VCRs except video heads Video heads will be covered for a period of six months Six months All pan and tilts scanners or preset lenses used in continuous motion applications preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs
3. QUICK START by Schneider Electric Endura UDI5000 CAM Configuration Software For use with Third Party IP Devices C4625M 9 09 Contents About this GUIDE a edd ans gas Gack bya neben bg Accessing the Configuration Application sn ea he la AM EDDIE a Logging On to the Application from a Web Browser ooooooooocococooo rr Logging On to the Application from the WS5000 Software o oooocococoocococor rr Exitingsthe Application ee ee Be eed de behead clade YY ees A nee Aboutsthe Main Rage u vi das mar en Ne a e da dl Ou ee EA el a A o lo Channel Management ze est a acho ALAA e Mint ees Ban Mle AGES cele Mel ke A di Ween ee Associating a Camera withia Channel u essen Re Helma dia Disconnecting a Camera 2 nnn E EREEREER betes Tracking Capacity Availability and Usage s csce cence er aden en ann a aa ee etal aa aaa Editing Camera SEIS ec ee a le ity as testa aed AS A erg Configuring Additional Camera Settings A A tt sine RE ee he a Lemma eee aie hak Taam een eda toate Locating Firmware Version Information 24 222422 228 44 deta de id ieh cae rad e Changing Network Settings from DHCP to Static oooooooocococoococo coreo ACCOUNT SENOS ne ernten conte aan tan Dada Ghanging d Password asinen me ls a es Ba tisk tes ner nee Adding or Editing the Security Question 2 22 22 A li DI IB ln ia I C4625M 9 09 About this Guide This guide provides instructions on operating the
4. UDI5000 CAM configuration application With this application you can perform the following tasks e Associate up to 16 standard resolution or megapixel third party IP cameras e Track system resource usage and capacity e _ Review and configure network settings e Configure device security settings The application is accessible over the Internet from a computer with Microsoft Internet Explorer 7 0 or later Mozilla Firefox 3 5 or later After you have associated cameras with the UDI5000 CAM you can view live and recorded video from any viewing station on the Endura system Refer to the operation manual for the viewing station for instructions Accessing the Configuration Application There are two ways to access the configuration application 1 directly from a Web browser or 2 from the Devices setup screen of the WS5000 advanced system management software LOGGING ON TO THE APPLICATION FROM A WEB BROWSER 1 Open a Web browser and type the IP address for the UDI5000 CAM in the Address field 2 Press Enter The Login screen appears UDI5000 CAM Forgot your password Login Figure 1 UDI5000 CAM Login Screen 3 Enter the password and click Login By default admin is the password The UDI5000 CAM configuration application main page appears NOTE Some third party cameras require a separate password to display their configuration settings If such a camera is already associated with the UDI5000 CAM a separate logon s
5. Used to set the password and security question for accessing the configuration application UDI5000 CAM E Channel Management g UDI Settings P Account Settings Change Password Enter New Password Re Enter Password Add Edit Security Question Enter Security Question Please read manual for first time password This question will be shown in case you have forgotten your password You will be requir Answer to Question Figure 2 UDI5000 CAM Configuration Application Main Page C4625M 9 09 Channel Management ASSOCIATING A CAMERA WITH A CHANNEL A camera should be associated with only one UDI5000 CAM Although a camera can transmit video to more than one UDI5000 CAM each subsequent video stream can impact camera performance Before you associate a camera with the UDI5000 CAM refer to the manufacturer s documentation to locate the following information e Manufacturer e Model number e P address 1 From the Channel Management tab click the Add button below the list of channels An unassigned channel appears in the list UDI5000 CAM Y Channel Management Channels New channel Camera Information Manufacturer Model Camera Credentials IP Address This field is required User Name Password 16 Channels Unassigned Total Capacity Utilization ET 100 LP UDI Settings P Account Settings Figure 3 Channel Management Tab 2 Select the camera manufacturer and model number from the Ca
6. creen appears You must enter the specific user ID and password for the camera before you can configure it from the UDI5000 CAM configuration application Refer to the camera manufacturer s documentation to locate the correct user ID and password If necessary contact a system administrator for this information LOGGING ON TO THE APPLICATION FROM THE WS5000 SOFTWARE 1 Start the WS5000 advanced system management software and then open the Setup screen 2 On the Devices tab select the UDI5000 CAM from the cameras list If necessary filter the list to display only universal devices 3 Click the Configure button The Login screen appears in a Web browser window 4 Enter the password and click Login By default admin is the password The UDI5000 CAM configuration application main page appears EXITING THE APPLICATION There are two ways to exit or close the application main page e Click the Exit button B gt to close the application main page and return to the Login screen e Click the Close button in the upper right corner of the Web browser window 4 C4625M 9 09 About the Main Page The main application page is divided into the following three tabs Channel Management Used to associate cameras with the UDI5000 CAM monitor bandwidth utilization and access a configuration application if one is provided by the camera vendor x UDI Settings Used to verify system information settings and to update network settings Q Account
7. identified throughout this document are trademarks or registered trademarks of their respective companies The absence of a trademark or registered trademark from this document does not constitute a waiver of intellectual property rights Copyright 2009 Pelco Inc All rights reserved PELLO by Schneider Electric www pelco com Pelco Inc Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120
8. le resources for the UDI5000 CAM refer to Total Capacity Utilization beneath the Channels list EDITING CAMERA SETTINGS Basic camera information and camera credentials that are needed by the UDI5000 CAM are displayed on the Channel Management tab 1 From the Channel Management tab select a camera in the Channels list Camera information and credentials appear on the tab 2 Edit any of the credentials and click Apply The settings are changed and stored on the UDI5000 CAM NOTE Only those settings that are required to associate the camera with the UDI5000 CAM appear on this tab To edit other settings click the Configure button and update the settings directly on the camera CONFIGURING ADDITIONAL CAMERA SETTINGS 1 From the Channel Management tab select a camera in the Channels list 2 Click the Configure button A separate Web browser window opens and displays the configuration application for the third party camera 3 Use this application to locate camera firmware information to set the date and time display for the camera and to set up other advanced functions Refer to the camera manufacturer s documentation for instructions C4625M 9 09 7 UDI Settings LOCATING FIRMWARE VERSION INFORMATION The following system information for the UDI5000 CAM software is located on the UDI Settings tab e Base Firmware Version The version of software that was originally installed on the unit at the factory e Updated Firmware Versi
9. mera Information fields 3 Enter the credentials for the camera including its IP address user name and password The Endura system requires the user name and password to transmit configuration information and video streams between the camera and the Endura viewing stations This information is configured directly on the camera and is not maintained in the Endura system If you change the user name or password on the camera you must update it for the camera association in the UDI5000 CAM as well 4 Click Apply The camera appears in the Channels list and a preview of the live video appears above the camera information 6 C4625M 9 09 DISCONNECTING A CAMERA 1 From the Channel Management tab select a camera in the Channels list 2 Click the Delete button The camera is removed from the list and its camera information is deleted from the system TRACKING CAPACITY AVAILABILITY AND USAGE The UDI5000 CAM capacity represents a combination of processing power network bandwidth memory stream type frame rate and size of the group of pictures that are required to transmit video from a camera The Channel Management tab displays the amount of these system resources that are used by each camera and that are still available for the UDI5000 CAM To monitor resource usage for each camera refer to the Channels list A percentage indicates the total system resources consumed by the camera compared to a 100 percent total To monitor the availab
10. nditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS To expedite parts returned for repair or credit please call Pelco at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair and designated return location All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid 12 23 08 Green The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002 95 EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment e REVISION HISTORY Manual Date Comments C4625M 9 09 Original version Pelco the Pelco logo Camclosure DigitalSentry Endura Esprit ExSite Genex Intelli M Legacy and Spectra are registered trademarks of Pelco Inc DLP is a registered trademark of Texas Instruments Incorporated All product names and services
11. on The current version of the software which represents the most recent software update Refer to this information when you contact Pelco Product Support CHANGING NETWORK SETTINGS FROM DHCP TO STATIC The first time you connect the unit to your Endura network the IP address is set automatically using Dynamic Host Configuration Protocol DHCP If your system is set up to use static IP addresses you can change it from the UDI Settings tab 1 Locate the Network Settings section on the UDI Settings tab and select Static The IP address subnet mask broadcast address and gateway address are deleted 2 Enter the correct static information and click Save UDI5000 CAM chanel Hagener LP UDI Settings System Information Base Firmware Version 1 0 0 0175 Updated Firmware Version 1 0 0 0175 Network Settings DHCP Static IP Address Subnet Mask Broadcast Address Gateway Address DNS Server 1 DNS Server 2 Figure 4 UDI Settings Tab C4625M 9 09 Account Settings Information entered on this tab affects the UDI5000 CAM This information does not affect any security settings you have created for the third party cameras from their own configuration utilities UDI5000 CAM Channel Management g UDI Settings P Account Settings Change Password Enter New Password Re Enter Password Add Edit Security Question Enter Security Question Please read manual for first time password This questi
12. on will be shown in case you have forgotten your password You will be requir Answer to Question Figure 5 Account Settings Tab CHANGING A PASSWORD 1 From the Account Settings tab Q enter the new password in the two fields that are provided refer to Figure 5 2 Click Save The password remains changed until you edit it again ADDING OR EDITING THE SECURITY QUESTION You must select a security question and response so that you can change the password for the application If you forget the password the application will ask for the security question to validate that you are an authorized user il 2 3 C4625M 9 09 Display the Account Settings tab Q if it is not already displayed refer to Figure 5 Enter a security question in the field provided Enter an answer to the question in the field provided Click Save C4625M 9 09 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years Fiber optic products TW3000 Series unshielded twisted pair UTP transmission products CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models Three years Pelco branded fixed camera models CCC1390H Series C10DN Series C10CH Series IP3701H Series and IX Series EH1
Download Pdf Manuals
Related Search
Related Contents
Sony VGN-BX540 Replacement Instructions Sony TC-TX333 User's Manual G3 Ferrari G10024 barbecue HORSES FLASH - Aditivos y Nutrientes para la Nutrición Animal, SL 6-SPEED MIXER GRINDER MCPR06-WSO-049 Philips Softone Luster energy saving bulb 8718291657927 Using VMware Horizon Client for Android Bahrain - Fujitsu Copyright © All rights reserved.