1. Cable Type Maximum Distance RG59 U 750 ft 229 m RG6 U 1 000 ft 305 m RG11 U 1 500 ft 457 m Cable requirements 75 ohm impedance All copper center conductor All copper braided shield with 95 braid coverage Table B shows are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Table B 24 VAC Wiring Distances Wire Gauge 2 18 16 4 12 10 w 283 451 716 1142 1811 2880 86 137 218 348 551 877 E 141 225 38 571 905 1440 6 a 42 68 108 174 275 438 y S Z 52 S 94 150 238 380 603 90 BS lt 28 150 72 115 183 292 E E ES w 7 12 179 285 452 720158 21 34 54 86 137 219 E sa 56 90 143 228 362 576 17 27 43 69 110 175 NOTE Distances are calculated in feet values in parentheses are meters For example an enclosure that requires 30 VA and is installed 94 ft 28 m from the transformer would require a minimum wire gauge of 20 AWG Models with heaters require 24 VAC for the heater the heater uses 58 VA If the camera uses 24 VAC add the camera power to that of the heater and refer to Table B to determine the size of wire to use C1458M
2. stoves or other apparatus including amplifiers that produce heat Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture the apparatus does not operate normally or the apparatus has been dropped To reduce the risk of shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and must not be installed where exposed to rain and moisture Only use replacement parts Pelco recommends After replacing repairing this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry The installation method and materials should be capable of supporting four times the weight of the unit and equipment The product and or manual may bear the follow
3. J 9 08 13 REVISION HISTORY Manual Date Comments 01458 4 97 Original version C1458M A 7 97 Added indoor pendant models C1458M B 12 97 Added DF5C and DF5M pendant models Added outdoor pendant models Removed column for 22 gauge wire from Table B Added dimensions for pendant models to Figure 17 C1458M C 2 98 Deleted references to SD5 P which is covered in C1459M Deleted exploded assembly diagrams which are included in C1458SM Changed manual pagination C1458M D 5 98 Revised model numbers Revised camera installation instructions Removed all material relating to the DF5C and DF5M models Revised the procedures under Sec tion 3 7 Lower Dome Installation Revised one Note and deleted another under Section 4 1 Pendant Mount Installtion Added a Note in Section 4 2 Surface Mount Installation 6 98 Revised Section 4 1 and Figures 9 and 11 because of modifications to top mount C1458M E 5 00 Revised installation instructions and illustrations Revised camera installation instructions removed references to obsolete camera models Updated manual to new format C1458M F 1 02 Revised installation instructions and illustrations Added illustrations to show power connections for outdoor models C1458M G 8 02 Added CE certification Revised mportant Safeguards and Warnings 5 05 Revised dimension drawing callout from 7 25 18 13 to 7 25 18 41 C1458M H 7 06 Revised per ECO 05 11636 which incorporated Spectra Ill style back boxes a
4. claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed he price paid by the Dealer to Pelco for such Products In no event will Pelco be iable for any special incidental or consequential damages including loss of use oss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number sales order number or Pelco invoice number 3 Details of the defect or problem f there is a dispute regarding the warranty of a product that does not fall under he warranty conditions stated above please include a written explanation with he product when returned ethod of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS To expedite parts returned for repair or credit please call Pelco at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair and desig
5. of the back box to prevent moisture or cold air inside of the mount from entering the unit and causing condensation on the dome Use a product such as duct seal or a foam insulation spray that is available from an electrical supply store Screw the back box into the mount Figure 5 Installing Pendant Mount and Back Box PENDANT MODELS SURFACE MOUNT 1 If you have an outdoor model remove the sun shield 2 Remove the black tilt table assembly inside of the back box by removing the nuts and washers that hold the three legs to the back box 3 Remove the top mount by removing the three screws and lock washers inside the back box Figure 6 Removing the Top Mount from the Back Box 4 Using the back box as a template mark the three fastener holes and the center hole for wiring Using a drill make the holes for the fasteners and wiring 5 Pull a coaxial cable for the camera through the center hole in the mounting surface Also pull the wiring for power through the hole Refer to Table A and Table B in the Appendix on page 13 for wiring distances 6 If you are installing the mount outdoors apply sealant around the holes in the mounting surface 7 Position the back box over the mounting holes and pull the wiring into the back box Secure the back box to the mounting surface with appropriate hardware for your installation 8 Reinstall the tilt table assembly Figure 7 Installing the Surface Mount Pendant Back Box C1458M J
6. 9 08 CAMERA AND LENS If the camera and lens are already installed begin with step 2 1 If applicable extend the lens to the maximum length before installing the camera in the back box Attach the camera to the tilt table with the 1 4 20 screw flat washer and lock washer supplied IN CEILING MODEL PENDANT MODEL Figure 8 Installing the Camera and Lens 2 For indoor models connect the power wires and video cable to the camera 3 For outdoor models connect the video cable to the camera Connect the power wires to the circuit board mounted on the side of the back box Connect the wires to the connectors marked AC IN HI line voltage AC IN NT neutral and GND Attached to the circuit board are a black wire and a red wire with spade lugs on the end connect these to the power connectors on the camera OS 8 O D O O LO TO CAMERA Figure 9 Connecting Camera Power for Outdoor Models 4 Turn on power and adjust the tilt table for desired viewing of the camera on the monitor Refer to the camera and lens manuals to set up the camera and lens for proper operation C1458M J 9 08 9 LOWER DOME IN CEILING MODELS 1 Snap the clip on the end of the trim ring leash into the hole on the lip of the back box 2 Line up the snaps on the trim ring with the mounting screws on the back box Snap the trim ring into the plastic snap washers on the mounting screws Figure 10 Installing the
7. D F5 PG 0 except clear lower dome bubble virtually no light loss Outdoor gray fixed mount pendant dome heater and blower smoked lower dome bubble f 0 5 light loss Same as DF5 PG E0 except clear lower dome bubble virtually no light loss NOTE DomePak models include factory installed and back focused camera and lens however the model numbers above do not include a camera and lens C1458M J 9 08 Installation PARTS LIST The DF5 shipping carton contains two boxes Inspect each box to make sure all parts are present IN CEILING MODELS Back Box Oty Description 1 Back box with tilt table assembly installed includes camera and lens if specified with order 1 Parts bag 1 Safety chain bracket 1 Compass tool 1 Flat washer models without camera 1 Split lock washer models without camera 1 Screw models without camera Lower Dome Qty Description 1 Acrylic lower dome with trim ring PENDANT MODELS Back Box Qty Description 1 Back box with tilt table assembly installed includes camera and lens if specified with order 1 Parts bag models without camera Flat washer 1 Split lock washer 1 Screw Lower Dome Qty Description 1 Acrylic lower dome with trim ring 1 Thread compound C1458M J 9 08 BACK BOX IN CEILING MODELS HARD CEILINGS 1 Locate the center point of the mounting location Drill a hole in the ceiling using a 3 32 inch drill Insert the compass tool into the hole Use a pencil and the co
8. INSTALLATION DF5 Series Fixed Mount Dome C1458M J 9 08 Contents Important Safety INStructlons 0 A A a ica 3 DESC TOMI da a da de ca o dedo e e O A 4 Moderato e o rada 4 nstallatio rr a o ao oe dd 5 E A A A 5 In Ceiling ModelS c ccs A ean ls el 5 Pendant WOGEIS lek EO eae ASN A LAR AE SA ane CAE A ttt Se th 5 DADO a craters A A e eS ds 6 In Ceiling Madels Hard GelInGs sac rl ada ld becaria 6 In Ceiling Models Suspended Cell oo A negate es ay eka Gad 7 Pendant Models2Pendant Mount it tcc calito A tis e dle a toate a le ued shail ES 7 Pendant Models Surface Mount secta ii Ae es Bae aa ak da ete ads 8 Camera adios e o e me ed EOE e AO Gate ct 9 DM A A id y dad 10 inceng Models rd diosa iaa 10 Pendant Models ociosa cas e od as a e aa ds aa ados 10 Maintenance serena roseta rl taa teatre 11 EU a e e e a E LU Oa lrg he 11 Mtenor surata Make ont a fae A e Wok GIS e o do e O eE Ad Weal WE S 11 SMOKE ROCA A A Aa e 11 A O nha ees solihta ately aiid eh so goes he eee a8 11 Recommended Cleaning Procedure vii A A Ge ae 11 CC e edad de de o e tel St e a a 12 A A A A A IA 13 2 C1458M J 9 08 Important Safety Instructions 4 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers
9. Lower Dome for In Ceiling Models PENDANT MODELS 1 Hanging down from the back box is a flexible strap called the trim ring leash Lift the lower dome near the back box so that the trim ring leash touches the lower dome 2 Look inside the lower dome and note the two raised retainer screws Slide the hole in the end of the trim ring leash over one of the raised retainer screws Tuck the end of the trim ring leash behind the raised sheet metal stop and make sure the leash will hold the lower dome 3 Line up the two notches on the outside edge of the lower dome with the two captive screws on the back box Push the lower dome inside the back box and tighten the screws to secure the lower dome Figure 11 Installing the Lower Dome for Pendant Models 10 C1458M J 9 08 Maintenance Clean the acrylic dome as needed Be careful not to scratch the surfaces of the dome EXTERIOR SURFACE Clean the dome s exterior surface with a nonabrasive cleaning cloth and agent that is safe for acrylic plastic Either liquid or spray cleaner wax suitable for fine furniture is acceptable INTERIOR SURFACE SMOKED OR CLEAR To clean the interior of smoked or clear domes use the same instructions as the exterior surface CHROME OR GOLD The inside surface of a chrome or gold dome is easily scratched Use the following precautions to maintain the dome s surface Always handle the dome from the outside of its circular flange Never touch the coat
10. ars on PMCL200 300 400 Series LCD monitors Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Ill Spectra Mini Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit Ti and TI2500 Series thermal imaging products Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty Two years on Intelli M elDC controllers One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability or any
11. ed inside surface The acid in your fingerprints will eventually etch the coating if the fingerprints are not carefully removed according to the information in Recommended Cleaning Procedure f dust or other contaminants accumulate on the dome s interior remove the debris with compressed air Compressed air cans are available from photographic equipment or electronic supply dealers f heavy residue accumulates and cannot be removed with air pressure rinse with water and immediately dry with air pressure so that water spots will not remain Avoid wiping the coated surface with direct hand pressure it will easily abrade unless extreme care is taken f scratched the dome cannot be repaired RECOMMENDED CLEANING PROCEDURE If internal wiping is necessary avoid hand rubbing Instead make a wick as follows 1 2 C1458M J 9 08 Use a very soft paper towel Roll a section into a tightly wound tube Tear the tube in half and wet the fuzzy end of the wick with a solution of isopropyl alcohol diluted with water Hold the dome with its opening facing downward Wipe the interior of the dome with the wet end of the wick using a circular motion start from the outside and spiral into the center Use a new wick for every two passes over the dome Specifications ELECTRICAL Input Voltage Input Power MECHANICAL Construction Back Box Mounting Bracket Lower Dome Trim Ring Indoor Dutdoor GENERAL Environment Operating Tem
12. ing marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION A This symbol indicates that there are important operating and RISK OF ELECTRIC SHOCK C1458M J 9 08 DO NOT OPEN maintenance instructions in the literature accompanying this unit Description DF5 Series domes are discreet surveillance domes that are designed for indoor or outdoor use Models include pendant and in ceiling versions In ceiling models have plenum rated back boxes and can be installed in hard ceilings or standard 2 x 2 ft 6 x 61 cm suspended ceilings Indoor pendant models come in light gray or black finish Outdoor pendant models are light gray only and include a heater that allows operation down to 60 F 51 C MODELS DF5 0 DF5 1 F5 2 F5 3 F5 PB 0 FS PB 1 F5 PG 0 F5 PG 1 F5 PG E0 FS PG El D D D D D D D D Indoor fixed mount in ceiling dome smoked lower dome bubble f 0 5 light loss Same as DF5 0 except clear lower dome bubble virtually no light loss Same as D Same as D F5 0 except chrome lower dome bubble f 2 0 light loss F5 0 except gold lower dome bubble f 2 0 light loss Indoor black fixed mount pendant dome smoked lower dome bubble f 0 5 light loss Same as D F5 PB 0 except clear lower dome bubble virtually no light loss Indoor gray fixed mount pendant dome smoked lower dome bubble f 0 5 light loss Same as
13. mpass tool to draw a circle on the ceiling Carefully cut out the circle Figure 1 Preparing the Ceiling 2 Attach a conduit fitting not supplied lock nut not supplied and safety chain bracket Install a safety chain cable not supplied that will support up to 16 pounds 7 3 kg Install one end of the safety chain cable to the safety chain bracket and the other end to a support structure in the ceiling ATTACH SAFETY CHAIN HERE NOT SUPPLIED Figure 2 Attaching the Safety Chain 3 Prepare the wiring for camera and lens power refer to Table A and Table B in the Appendix on page 13 for wiring distances Pull the wiring into the back box through the conduit fitting 4 Compress the spring clips on the back box and push it through the hole until the clips spring back Tighten the screws until you hear a clicking noise NOT SUPPLIED NOT SUPPLIED CEILING CEILING Figure 3 Installing the In Ceiling Back Box C1458M J 9 08 IN CEILING MODELS SUSPENDED CEILING 1 Remove the ceiling tile from the ceiling Insert the compass tool supplied into the center of the tile If necessary use a 3 32 inch bit to drill a hole Draw a circle on the tile using the compass tool and a pencil Carefully cut out the circle NOTE The ceiling tile cannot be thinner than 0 50 inches 1 27 cm or thicker than 1 75 inches 4 45 cm 2 Figure 4 Preparing the Ceili
14. nated return location All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Green The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002 95 EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 Australia Finland France Germany Italy Macau The Netherlands Russia Singapore South Africa Spain Sweden United Arab Emirates United Kingdom United States
15. nd heater blower assemblies C1458M I 11 06 Corrected input power requirements C1458M J 9 08 Updated manual to indicate the conduit fitting and lock nut are no longer supplied Pelco the Pelco logo Camclosure Digital Sentry Endura Esprit ExSite Genex Intelli M Legacy and Spectra are registered trademarks of Pelco Inc Copyright 2008 Pelco Inc All rights reserved Spectra Ill is a trademark of Pelco Inc DLP is a registered trademark of Texas Instruments Inc C1458M J 9 08 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on fiber optic products and TW3000 Series unshielded twisted pair UTP transmission products Three years on Spectra IV products Three years on Genex Series products multiplexers server and keyboard Three years on DX Series digital video recorders DVR5100 Series digital video recorders Digital Sentry Series hardware products DVX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products Three years on Camclosure and Pelco branded fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Three ye
16. ng Tile Attach a conduit fitting not supplied lock nut not supplied and safety chain bracket Attach to the bracket one end of a safety chain cable not supplied that will support up to 16 pounds 7 3 kg Refer to Figure 2 Do not attach the other end of the safety chain yet Compress the spring clips on the back box and push it through the hole until the clips spring back Tighten the screws until you hear a clicking noise Reinstall the ceiling tile Remove an adjacent ceiling tile Prepare the wiring for camera and lens power refer to Table A and Table B in the Appendix on page 13 for wiring distances Pull the wiring into the back box through the conduit fitting Attach the safety chain to a support structure refer to Figure 2 and Figure 3 on page 6 Replace the adjacent ceiling tile PENDANT MODELS PENDANT MOUNT 1 C1458M J 9 08 Install the mount for the pendant dome Refer to the instructions supplied with the mount If you are installing the dome outdoors make sure the mount is properly sealed to keep moisture from damaging the structure to which it is attached Pull a coaxial cable for the camera through the mount Also pull the wiring for power through the mount Refer to Table Aand Table B in the Appendix on page 13 for wiring distances Pull the wiring from the mount into the back box Apply thread compound to the threads on the back box If you are installing the dome outdoors seal the inside of the pipe portion
17. perature Indoor Outdoor Weight In Ceiling without camera Pendant Indoor Outdoor 24 VAC outdoor models only 58 VA for heater Aluminum Steel Acrylic Eggshell white molded plastic UL94V0 Plastic Indoor or outdoor depends on model 32 to 120 F 0 to 49 C 60 to 122 F 51 to 50 C continuous operation 50 to 122 F 46 to 50 C continuous operation prevents icing 40 to 122 F 40 to 50 C continuous operation de ices within 3 hours after power up 2 80 Ib 1 27 kg 3 65 Ib 1 66 kg 5 30 Ib 2 40 kg Assumes no windchill factor for detailed test conditions contact Pelco CAMERA Maximum Camera and Lens Size CERTIFICATIONS RATINGS UL cUL NEMA 1 IP 20 NEMA 4 IP 66 5 25 8 52 r 21 64 gt 7 25 1844 1 H 6 6 10 78 t 5 00 L x 2 75 W x 2 75 H 12 70 x 6 99 x 6 99 cm Models DF5 0 DF5 1 DF5 2 DF5 3 DF5 PB 0 DF5 PB 1 DF5 PB 2 DF5 PB 3 DF5PG 0 DF5PG 1 DF5PG 2 DF5 PG 3 DF5PG E0 DF5PG E1 In ceiling models Pendant models TOP PORTION OF BACK BOX IS REMOVABLE FOR SURFACE MOUNT APPLICATIONS DOME IS SECURED TO CEILING BY MOUNTING BRACKET 6 75 17 15 5 83 14 80 5 90 14 99 8 25 20 96 5 90 14 99 NOTE VALUES IN PARENTHESIS ARE CENTIMETERS ALL OTHERS ARE INCHES C1458M J 9 08 Appendix Table A Video Coaxial Cable Wiring Distances