Home

Peavey Triumph PAG 120 User's Manual

image

Contents

1. A Intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons Intended to alert the user to the presence of important operating and maintenance servicing instruc tions in the literature accompanying the product CAUTION Risks of electrical shock DO NOT OPEN CAUTION To reduce the risk of electric shock do not remove cover No user serviceable parts inside Refer Servicing to qualified service personnel WARNING To prevent electrical shock or fire hazard do not expose this appliance to rain or moisture Before using this appliance read the operating guide for further warnings sobre la operaci n y mantenimiento en la literatura que viene con el producto Este s mbolo tiene el prop sito de alertar al usuario de la presencia de voltaje peligroso que no tiene aislamiento dentro de la caja del producto que puede tener una magnitud suficiente como para constituir riesgo de corrientazo PRECAUCION Riesgo de corrientazo No abra PRECAUCION Para disminu r el riesgo de corrientazo no abra la cubierta No hay piezas adentro que el usuario pueda reparar Deje todo mantenimiento a los t cnicos calificados ADVERTENCIA Para evitar corrientazos o peligro de incendio no deje expuesto a la lluvia o humedad este aparato Antes de usar este aparato lea m s advertencias en la gu a de operac
2. POWER LED DEL t moin de mise sous tension 19 3 allume lorsque l ampli re oit l alimentation CA STANDBY SWITCH S lecteur attente 20 Permet de s lectionner l tat de l ampli mode Active actif ou mode Standby attente En position Stand by l amplificateur ne fonctionne pas mais les lampes tubes restent chaudes pour permettre de le remettre en service sans d lai POWER SWITCH Interrupteur d alimentation 21 Mettre Pinterrupteur en position On La lampe t moin rouge DEL s illumine indiquant que l appareil est aliment en courant EFFECTS PREAMP SPEAKER OUTPUTS 220 240 V V e RISK OF ELECTRIC SHOCK 50 69 Hz MAIN AUX DO NOT OPEN 200 WATTS 8 OHMS 4 OHMS SEND RETURN OUT REMOTE SWITCH 60 W RMS 22 V RMS EFFECTS PREAMP SPEAKER OUTPUTS zu RISK OF ELECTRIC SHOCK MAIN AUX 400 WATTS DO NOT OPEN 8 OHMS 4 OHMS SEND RETURN OUT REMOTE SWITCH 120 W RMS 31 V RMS GROUND SWITCH S lecteur de mise terre 22 Commutateur rotatif trois positions devant la plupart du temps tre en position centrale z ro Dans cer taines situations un bruit de ronflement ou un bourdonnement audible peut provenir des haut parleurs de puissance Dans ce cas bougez le s lecteur de mise terre jusqu en position positive ou n gative ou ou jusqu ce que le bruit diminue NOTE Si le probl me de bruit persiste consultez votre d taillant autoris Peavey la fabrique Peav
3. FOOTSWITCH JACK Enchufe hembra de interruptor remoto 26 Se suministra para la conexi n del pedal interruptor de control remoto El pedal se utiliza para desactivar la reverberaci n posterior al circuito 1 para efectos y posterior al circuito 2 para efectos SPEAKER OUTPUTS Salidas de altavoces 27 Se suministran enchufes hembras de salida de altavoces de 4 de pulgada principales y auxiliares El enchufe hembra principal es de 8 ohms y el enchufe hembra auxiliar es de 4 ohms Cuando ambos enchufes hembras est n conectados la impedancia del amplificador es de 4 ohms LINE CORD 120 V PRODUCTS ONLY Cable de corriente para 120 y solamente 28 Para su protecci n hemos incorporado un cable de 3 polos con polo a tierra No es recomendable remover la pata del polo a tierra bajo ninguna circunstancia se recomienda un adaptador en caso necesario Esto reducir ruidos y peligrosos corrientazos FRANCAIS Veuillez vous r f rer au front panel line art situ dans la section en langue anglaise de ce manuel HIGH GAIN INPUT Entr e haut gain 1 Cette prise s utilise avec la plupart des guitares lectriques Elle donne un gain sup rieur de 6 dB l entr e Low Gain LOW GAIN INPUT Entr e faible Gain 2 Cette prise accepte les instruments tres haut niveau de sortie qui causeraient de la saturation distorsion sur l entr e High Gain Si les deux entr es sont utilis es simultan ment les niveaux sont
4. respectivamente PRE GAIN Control del preamplificador 7 Controla el nivel del volumen de la entrada del canal POST GAIN Control de ganancia posterior al preamplificador 8 Controla el nivel global de volumen del canal El ajuste final de nivel debe hacerse una vez que se haya con seguido el sonido deseado ULTRA GAIN SWITCH Interruptor de ganancia de ultra 9 Aumenta la ganancia global de sistema del canal Ultra Oprima a la posici n hacia adentro para activar CRUNCH GAIN SWITCH Interruptor de ganancia de crujido 10 Aumenta la ganancia global de sistema del canal crujido Oprima a la posicin hacia adentro para activar PRE GAIN Control del preamplificador 11 Controla el nivel del volumen de la entrada del canal POST GAIN Control de ganancia posterior al preamplificador 12 Controla el nivel global de volumen del canal El ajuste final de nivel debe hacerse una vez que se haya con seguido el sonido deseado BOTTOM Fondo 13 Un control de tono activo gradual 15 dB que vara el aumento o disminuici n de frecuencias bajas NOTA Este control no funciona en el canal Limpio BODY Cuerpo 14 Es un control de tono activo cima gradual 15 dB que var a el aumento o disminuicin de las frecuencias medias NOTA Este control no funciona en el canal Clean EDGE Filo 15 Un control de tono activo de estante 15 dB que var a el aumento o dismi
5. should be operated in its center or zero posi tion There may be some situations when audible hum and or noise will come from the loudspeaker If this situation arises position the ground switch to either positive or negative or or until the noise is minimized NOTE Should the noise problem continue consult your Authorized Peavey Dealer the Peavey Factory or a qualified service technician THE GROUND SWITCH IS NOT FUNCTIONAL ON 220 240 VOLT MODELS EFFECTS SEND 23 Output for supplying signals to external effects or signal processing equipment EFFECTS RETURN 24 Input for returning signals from external low level effects or signal processing equipment PREAMP OUT 25 The preamp output can be used to route the amplified signal to a mixing console tape recorder etc Connect the preamp output using a shielded cable to an input of the tape recorder mixer etc This patch does not affect the operation of the amplifier FOOTSWITCH JACK 26 Provided for the connection of the supplied remote footswitch Footswitch switch 1s used to select the Ultra Gain Crunch Gain or Normal channels and defeat reverb SPEAKER OUTPUTS 27 Speaker output A jacks are provided for main and auxiliary Main jack is 8 ohms impedance and auxiliary jack is 4 ohms When both jacks are engaged amplifier impedance is 4 ohms LINE CORD 120V PRODUCTS ONLY 28 For your safety we have incorporated a 3 wire line mains cable with proper grounding
6. NOT OPEN 8 0HMS 4 OHMS SEND RETURN OUT REMOTE SWITCH 60 W RMS 22 V RMS EFFECTS PREAMP SPEAKER OUTPUTS 00 RISK OF ELECTRIC SHOCK MAIN AUX DO NOT OPEN 400 WATTS 8 OHMS SEND RETURN OUT REMOTE SWITCH 120 W RMS 31 V RMS GROUND SWITCH Interruptor de tierra 22 Un interruptor tipo balanc n de tres posiciones que en la mayor a de las aplicaciones debe ser operado en su posici n del centro o cero 0 Puede haber situaciones cuando un zumbido audible salga del altavoz Si esta situaci n occure ajuste la posici n del interruptor de tierra a positivo o negativo o o hasta que el ruido disminuya NOTA Si el problema de ruido contin a consulte su representante autorizado de Peavey la f brica de Peavey o un t cnico de servicio calificado EL INTERRUPTOR DE TIERRA NO FUNCIONA EN LOS MODELOS DE 220 240 VOLTIOS EFFECTS SEND Env o de efectos 23 Salida para enviar se ales a efectos externos o equipos procesadores de se al EFFECTS RETURN Retorno de efectos 24 Entrada para el retorno de se ales procedentes de equipos de efectos externos de bajo nivel o de procesadores de se al PREAMP OUT Salida de preamplificador 25 La salida del preamplificador puede usarse para mandar la se al a una consola de mezcla grabadora etc Conecte la salida del preamplificador utilizando un cable blindado a una entrada de la grabadora mezclador etc Esta interconexi n no afecta la operaci n del amplificador
7. SLECT RETURN F SWITCH MASTER PREAMP OUT ESPA OL Consulte los diagramas del panel delantero en la secci n de ingl s de este manual HIGH GAIN INPUT Entrada de ganancia alta 1 Se usa para la mayor a de las guitarras el ctricas Tiene 6 dB m s volumen que la entrada de baja ganancia LOW GAIN INPUT Entrada de baja ganancia 2 Se suministra para instrumentos que tienen una salida extremadamente alta la cual puede causar la sobrecarga distorsi n de la entrada de alta ganancia Si se usan ambas entradas simult neamente el nivel de salida es el mismo ambos son de baja ganancia CLEAN GAIN Ganancia 3 Controla el volumen del canal BRIGHT SWITCH Interruptor de brillo 4 Proporciona un impulso preajustado a las frecuencias de tiple Para activar oprima el interruptor a la posici n hacia adentro La funci n de brillo solamente afecta el canal limpio CHANNEL SELECT SWITCH Interruptor de seleccin de canal 5 Permite la selecci n del canal Ultra o Limpio y la posici n hacia afuera selecciona el canal limpio NOTA Tambi n se pueden seleccionar los canales con el pedal interruptor remoto Si desea selecci n a con trol remoto el interruptor de canal debe estar en la posici n hacia adentro Ultra LOW MID amp HIGH EQ Ecualizador de frecuencias graves medias y agudas 6 Controles de tono pasivo que regulan las frecuencias graves medias y altas
8. VORSICHT Um das Risiko eines elektrischen Schlages zu vermeiden nicht die Abdeckung enfernen Es befinden sich keine Teile darin die vom Anwender repariert werden k nnten Reparaturen nur von qualifiziertem Fachper sonal durchf hren lassen ACHTUNG Um einen elektrischen Schlag oder Feuergefahr zu vermeiden sollte dieses Ger t nicht dem Regen oder Feuchtigkeit ausgesetzt werden Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen ENGLISH n Eed HIGH LOW CLEAN GAIN Y a OS ZN N E CE GAIN a is aaa REVERB a dum GAIN GAIN Cal se Lp Oe d 50 0 010 0 20 0100 010 0 E 00 REE STANDBY POWER HIGH LOW CLEAN GAIN A TN A REVERB MASTER STANDBY POWER GAIN GAIN EISE 0 0 9 010 Os jo o DD 2 t3 e 10 11 12 13 14 15 16 17 18 19 20 21 ai ond pun Ra MIRR US EEE ee RA 3 n K Sie H GE HIGH GAIN INPUT 1 Used for most electric guitars It is 6 dB louder than the Low Gain input LOW GAIN INPUT 2 Provided for instruments that have extremely high outputs which can result in overdriving distorting the High Gain input If both inputs are used simultaneously the output levels are the same both are Low Gain CLEAN GAIN 3 Controls the channel volume BRIGHT SWITCH 4 Provides a preset boost to treble frequencies To activate depress the switch to its in position The bright function affects only the clean channel CHANNEL SELECT SWITCH 5 Allows selection of t
9. facilities It is not advisable to remove the ground pin under any circumstances If it is necessary to use the equipment without proper grounding facilities suitable grounding adaptors should be used Less noise and greatly reduced shock hazard exists when the unit is operated with the proper grounded receptacles SPECIFICATIONS PAG 60 POWER AMP SECTION 2 6L6GC s with 12AX7 driver Rated Power amp Load 60 W RMS into 8 or 4 ohms Power Clipping Typically 5 THD 1 kHz 120 V AC line 65 W RMS into 8 or 4 ohms Bias must be reduced to measure Frequency Response 0 2 dB 50 Hz to 20 kHz p 50 W RMS into 8 ohms Hum amp Noise Greater than 76 dB below rated power Power Consumption 200 W 50 60 Hz 120 V AC Domestic PREAMP SECTION 3 DAXT s The following specs are measured 1 kHz with the controls preset as follows Low amp High EQ Q 10 Mid EQ 0 Bright Out Ultra amp Crunch Posts 10 Gain switches out Bottom Body amp Edge 0 dB Reverb level 0 Master level 10 Nominal levels are with Pre Gains 5 Minimum levels are with Pre Gains 10 Preamp High Gain Input Impedance Very high Z 470 K ohm Ultra Channel with channel select in Nominal Input Level 46 dBV 5 mV RMS Minimum Input Level 64 dBV 0 6 mV RMS Subtract 15 dB with gain switch in Crunch Channel footswitch selected Nominal Input Level 34 dBV 20 mV RMS Minimum Input Level 52 dBV 2
10. 5 mV RMS Subtract 15 dB with gain switch in Clean Channel with channel select out Nominal Input Level 16 dBV 150 mV RMS Minimum Input Level 34 dBV 20 mV RMS Maximum Input Level 0 dBV 1 0 V RMS Preamp Low Gain Input 6 dB Pad Impedance High Z 44 K ohms All levels increased by 6 dB Effects Send Load Impedance 47 K ohms or greater Nominal Output 10 dBV 300 mV RMS Effects Return Impedance Very high Z 470 K ohm Designed Level 10 dBV 300 mV RMS Preamp Output Load Impedance 47 K ohms or greater Nominal Output 10 dBV 3 V RMS Remote Footswitch Special 3 button unit with LED indicators supplied System Hum amp Noise Nominal Level Clean Channel 20 Hz to 20 kHz unweighted Greater than 74 dB below rated power Special noise gate circuitry for Ultra amp Crunch Equalization clean channel only Custom Low Mid amp High passive type EQ Push Bright 6 dB 2 kHz Voicing Ultra and Crunch channels only Active Bottom Body and Edge EQ Push Gain Increases gain in Ultra and Crunch channels PAG 120 POWER AMP SECTION 4 6L6GC s with 12AX7 driver Rated Power amp Load 120 W RMS into 8 or 4 ohms Power Clipping Typically 5 THD 1 kHz 120 V AC line 130 W RMS into 8 or 4 ohms Bias must be reduced to measure Frequency Response 0 2 dB 50 Hz to 20 kHz 100 W RMS into 8 ohms Hum amp Noise Greater than 76 dB below rated pow
11. Anschluf des Verst rkers an einen Mixer eine Bandmaschine etc verwendet werden Verbinden Sie den Ausgang mit Hilfe eines abgeschirmten Kabels mit dem Eingang des entsprechenden Ger tes Dieser Anschlu beeinflu t die Funktionen des Verst rkers nicht REMOTE FOOTSWITCH JACK 27 Zum Anschlu des mitgelieferten Fu schalters Dieser dient zur Anwahl von Ultra Gain Crunch Gain oder Normal Channels SPEAKER OUTPUTS 28 Lautsprecher Ausgangsbuchsen sind vorgesehen F r Main und Auxiliary Die Main Buchse hat 8 ohm und die Auxiliary Buchse hat 4 ohm Wenn beide Buchsen in Betrieb sind betr gt die Verst rker Impedanz 4 ohm LINE CORD 120V products only Nur bei 120 Volt Ger ten 29 Zu Ihrer Sicherheit haben wir das Ger t mit einem dreiadrigen geerdeten Netzkabel versehen Es ist unter keinen Umstanden empfehlenswert den Erdungskontakt des Anschlu kabels zu l sen Falls es notwendig sein sollte das Equipment ohne die vorgesehene Erdung zu betreiben empfiehlt sich die Verwendung eines Groun ding Adaptors Die geringsten St rger usche und die h chste Sicherheit vor elektrischen Schl gen wird Jedoch durch die Benutzung der vorgesehenen Erdungsm glichkeiten erreicht THIS LIMITED WARRANTY VALID ONLY WHEN PURCHASED AND REGISTERED IN THE UNITED STATES OR CANADA ALL EXPORTED PRODUCTS ARE SUBJECT TO WARRANTY AND SERVICES TO BE SPECIFIED AND PROVIDED BY THE AUTHORIZED DISTRIBUTOR FOR EACH COUNTRY Ces clauses de garantie ne sont vaia
12. TE THESE LIMITED WARRANTIES ARE THE ONLY EXPRESSED WARRANTIES ON THIS PRODUCT AND NO OTHER STATEMENT REPRESENTATION WAR RANTY OR AGREEMENT BY ANY PERSON SHALL BE VALID OR BINDING UPON PEAVEY In the event of any modification or disclaimer of expressed or implied warranties or any limitation of remedies contained herein conflicts with applicable law then such modification disclaimer or limitation as the case may be shall be deemed to be modified to the extent necessary to comply with such law Your remedies for breach of these warranties are limited to those remedies provided herein and Peavey Electronics Corporation gives this limited warranty only with respect to equipment purchased in the United States of America INSTRUCTIONS WARRANTY REGISTRATION CARD 1 Mail the completed WARRANTY REGISTRATION CARD to PEAVEY ELECTRONICS CORPORATION POST OFFICE BOX 2898 MERIDIAN MISSISSIPPI 39302 2898 a Keep the PROOF OF PURCHASE In the event warranty service is required during the warranty period you will need this document There will be no identification card issued by Peavey Electronics Corporation 2 IMPORTANCE OF WARRANTY REGISTRATION CARDS AND NOTIFICATION OF CHANGES OF ADDRESSES a Completion and mail ng cf WARRANTY REGISTRATION CARDS Should notificatior become necessary for any cond tion that may require correction the REGISTRATION CARD wi help ensure that you are contacted and properly notified b Notce ot address changes I
13. alance der Clean Crunch und Ultra Kan le erreicht ist kann die Gesamtlautst rke des Ger ts mit diesem Master Level Regler angehoben oder abgesenkt werden STATUS LED 18 Leuchtet auf wenn der Verst rker aut Standby steht und zeight an da er nicht arbeitet POWER LED 19 Zeigt die eingeschaltete Netzspannung an STANDBY SWITCH 20 Erm glicht es den Verst rker mit abgeschaltetem Tonsignal betriebsbereit zu halten In der Standby Betriebsart werden die R hren weiter beheizt das Signal ist jedoch abgeschaltet POWER SWITCH Netzschalter 21 Bringen Sie den Schalter auf die ON Position Die rote Kontrollampe LED leuchtet und zeigt an dab das Ger t eingeschaltet ist EFFECTS PREAMP SPEAKER OUTPUTS RISK OF ELECTRIC SHOCK MAIN AUX DO NOT OPEN 200 WATTS 2 OHMS 4 OHMS SEND RETURN QUT REMOTE SWITCH 60 W RMS 22 V RMS EFFECTS PREAMP SPEAKER OUTPUTS EC RISK OF ELECTRIC SHOCK MAIN AUX 400 WATTS DO NOT OPEN 8 OHMS 4 OHMS SEND RETURN OUT REMOTE SWITCH 120 W RMS 31 V RMS GROUND SWITCH 22 Der Ground Schalter funktioniert nicht bei den 220 240 Volt Modellen EFFECTS SEND 23 Ausgang f r externe Effekte EFFECTS RETURN 24 Eingang f r r ckf hrende Signale von niederohmigen Effekten oder Signal Prozessoren EFFECTS RETURN 25 Eingang f r r ckf hrende Signale von niederohmigen Effekten oder Signal Prozessoren PREAMP OUT Vorstufenausgang 26 Dieser Ausgang kann zum
14. alors quivalents Low Gain CLEAN GAIN 3 Contr le le niveau de volume du canal BRIGHT SWITCH S lecteur de brillance 4 Produit un renforcement des fr quences aigu s Pour activer enclenchez le bouton la position In Cette fonction de brillance n affecte que le canal Clean CHANNEL SELECT SWITCH Commutateur de s lection de canal 5 Permet la s lection des canaux Ultra ou Clean La position Out active le canal Clean NOTE La s lection de canal peut aussi s effectuer distance l aide de l interrupteur au pied Le commutateur de s lection de canal doit alors tre en position In Ultra LOW MID amp HIGH EQ galisation graves moyennes et aigu s 6 R glages de tonalit passifs r glant respectivement les fr quences graves moyennes et aigues PRE GAIN 7 Contr le le niveau de volume l entr e du canal POST GAIN 8 Commande le volume global du canal Le r glage final de niveau doit tre effectu apr s avoir obtenu le sonorit d sir e l aide des autres r glages ULTRA GAIN SWITCH Interrupteur de gain Ultra 9 Hausse le gain global du canal Ultra Abaisser la position In pour activer CRUNCH GAIN SWITCH Interrupteur de gain Crunch 10 Hausse le gain global du canal Crunch Abaisser la position In pour activer PRE GAIN 11 Contr le le niveau de volume l entr e du canal POST GAIN 12 Comma
15. bles qu aux Etats Unis et au Canada Dans tour les autres pays les clauses de garantie et de maintenance sont fixees par le distributeur national et assuree par lul seion la legislation envigueur Diese Garantie ist nur in den USA and Kanada gultig Alle Export Produkte sind der Garantie und dem Service des Importeurs des jewelligen Landes unterworfen Esta garantia es valida solamente cuando el producto es comprado en E U continentales o en Canada Todos los productos que sean comprados en el extranjero estan sujetos a las garantias y servicio que cada distribuidor autorizado determine y ofrezca en los diferentes paises PEAVEY ONE YEAR LIMITED WARRANT Y REMEDY PEAVEY ELECTRONICS CORPORATION PEAVEY warrants this product EXCEPT for covers footswitches patchcords tubes and meters to be free from defects in material and workmanship for a period of one 1 year from date of purchase PROVIDED however that this limited warranty is extended only to the original retail purchaser and is subject to the conditions exclusions and limitations hereinafter set forth PEAVEY 90 DAY LIMITED WARRANTY ON TUBES AND METERS If this product contains tubes or meters Peavey warrants the tubes or meters contained in the product to be free from defects in material and workmanship for a period of ninety 90 days from date of purchase PROVIDED however that this limited warranty is extended only to the original retail purchaser and is also subject to the condi
16. e for our free booklet Shock Hazard and Grounding Power supply cords should always be handled carefully Never walk or place equipment on power supply cords Periodically check cords for cuts or signs of stress especially at the plug and the point where the cord exits the unit The power supply cord should be unplugged when the unit is to be unused for long periods of time If this product is to be mounted in an equipment rack rear support should be provided Metal parts can be cleaned with a damp rag The vinyl covering used on some units can be cleaned with a damp rag or an ammonia based household cleaner if necessary Disconnect unit from power supply before cleaning Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit does not operate correctly d The unit has been dropped or the enclosure damaged The user should not attempt to service this equipment All service work should be done by a qualified service technician This product should be used only with a cart or stand that is recommended by Peavey Electronics Exposure to extremely high noise levels may cause a permanent hearing loss Individuals vary considerably in susceptibility to noise induced hearin
17. ed to you by the AUTHORIZED PEAVEY DEALER in connection with your purchase from him of this product If the DEALER or SERVICE CENTER is unable to provide the necessary warranty service you will be directed to the nearest other PEAVEY AUTHORIZED DEALER or AUTHORIZED PEAVEY SERVICE CENTER which can provide such service OR b Ship the defective item prepaid to PEAVEY ELECTRONICS CORPORATION International Service Center Highway 80 Fast MERIDIAN MS 39301 including therewith a complete detailed description of the problem together with a legible copy of the original PROOF OF PURCHASE and a complete return address Upon Peavey s receipt of these items If the defect is remedial under these limited warranties and the other terms and conditions expressed herein have been complied with Peavey will provide the necessary warranty service to repair or replace the product and will return it FREIGHT COLLECT to you the purchaser Peavey s liability to the purchaser for damages from any cause whatsoever and regardless of the form of action including negligence is limited to the actual damages up to the greater of 500 00 or an amount equal to the purchase price of the product that caused the damage or that is the subject of or is directly related to the cause of action Such purchase price will be that in effect for the specific product when the cause of action arose This limitation of liability will not apply to claims for personal injury or damage to rea
18. er Power Consumption 400 W 50 60 Hz 120 V AC PREAMP SECTION 3 I2AXT s The follwoing specs are measured 1 kHz with the controls preset as follows Low amp High EQ E 10 Mid EQ 0 Bright out Ultra amp Crunch Posts 10 Gain switches out Bottom Body amp Edge 0 dB Reverb level 2 0 Master level 10 Nominal levels are with Pre Gains 5 Minimum levels are with Pre Gains 10 SPECIFICATIONS continued Preamp High Gain Input Impedance Very high Z 470 K ohm Ultra Channel with channel select in Nominal Input Level 46 dBV 5 mV RMS Minimum Input Level 64 dBV 0 6 mV RMS Subtract 15 dB with gain switch 1n Crunch Channel footswitch selected Nominal Input Level 34 dBV 20 mV RMS Minimum Input Level 52 dBV 2 5 mV RMS Subtract 15 dB with gain switch 1n Clean Channel with channel select out Nominal Input Level 16 dBV 150 mV RMS Minimum Input Level 34 dBV 20 mV RMS Maximum Input Level 0 dBV 1 0 V RMS Preamp Low Gain Input 6 dB Pad Impedance High Z 44 K ohms all levels are increased by 6 dB Effects Send Load Impedance 47 K ohms or greater Nominal Output 10 dBV 300 mV RMS Effects Return Impedance Very high Z 470 K ohm Designed Level 10 dBV 300 mV RMS Preamp Output Load Impedance 47 K ohms Or greater Nominal Output 10 dBV 3 V RMS Remote Footswitch Special 3 button unit with LED indicators supplied System Hum amp Noi
19. ey ou un technicien de service qualifi LE S LECTEUR DE MISE TERRE NE FONCTIONNE PAS SUR LES APPAREILS 220 240 VOLT EFFECTS SEND Envoi d effets 23 Prise de sortie servant fournir des signaux des appareils externes de traitement de signal ou d effets EFFETCS RETURN Retour d effets 24 Prise d entr e pour signaux provenant d appareils externes de traitement de signal ou d effets bas niveau PREAMP OUT Sortie pr ampli 25 La sortie pr ampli peut tre utilis e pour amener le signal une table de mixage un magn tophone etc Utilisez des c bles blind s pour brancher la sortie du pr ampli l entr e d un magn tophone d un m langeur ctc Ce branchement n affecte pas le fonctionnement de l amplificateur FOOTSWITCH JACK Prise pour p dale interrupteur 26 Cette prise peut recevoir la fiche de la p dale interrupteur incluse Cet interrupteur au pied peut tre utilis pour s lectionner les canaux Ultra Gain Crunch Gain ou Normal et d sactiver le Reverb SPEAKER OUTPUTS Sorties de haut parleur 27 Prises de sortie jack 4 6 35mm pour haut parleurs Main et Auxiliary L imp dance est de 8 ohms pour la prise principale Main et 4 ohms pour la prise secondaire Auxiliary Lorsque les deux Jacks sont utilis s l imp dance de l amplificateur est de 4 ohms LINE CORD 120V products only Cordon d alimentation pour appareils 120V seulement 28 Pour votre
20. f you move from the address shown on the WARRANTY REGISTRATION CARD you should not fy Peavey of the change of address so as to facilitate your receipt cf any bulletins or other forms of notification which may become necessary In connection wit any condition that may require dissemination of information or correction 3 You may cortact Peavey direct y by telephoning 601 483 5365 IMPORTANT SAFETY INSTRUCTIONS WARNING When using electric products basic cautions should always be followed including the following D tA Bb U N 16 17 18 Read all safety and operating instructions before using this product All safety and operating instructions should be retained for future reference Obey all cautions in the operating instructions and on the back of the unit All operating instructions should be followed This product should not be used near water i e a bathtub sink swimming pool wet basement etc This product should be located so that its position does no interfere with its proper ventilation It should not be placed flat against a wall or placed in a built in enclosure that will impede the flow of cooling air This product should not be placed near a source of heat such as a stove radiator or another heat producing amplifier Connect only to a power supply of the type marked on the unit adjacent to the power supply cord Never break off the ground pin on the power supply cord For more information on grounding writ
21. g loss but neary everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time The U S Government s Occupational Safety and Health Administration OSHA has specified the following permissible noise level exposures Duration Per Day In Hours Sound Level dBA Slow Response H No LC OB 0 E ao No Y 110 l4 or less 115 According to OSHA any exposure in excess of the above permissible limits could result in some hearing loss Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss if exposure is in excess of the limits as set forth above To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of produc ing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation Features and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39302 2898 U S A 601 483 5365 Telex 504115 Fax 484 4278 01992 80301323 Printed in U S A 8 92
22. he Ultra or Clean channel and the out position selects Clean NOTE Channel selection may also be accomplished by the remote footswitch If remote selection is desired the channel switch must be in the in Ultra position LOW MID amp HIGH EQ 6 Passive tone controls that regulate the low mid and high frequencies respectively PRE GAIN 7 Controls the input volume level of the channel POST GAIN 8 Controls the overall volume level of the channel The final level adjustment should be made after the desired sound has been achieved ULTRA GAIN SWITCH 9 Boosts the overall system gain of the Ultra channel Depress to the in position to activate CRUNCH GAIN SWITCH 10 Boosts the overall system gain of the Crunch channel Depress to the in position to activate PRE GAIN il Controls the input volume level of the channel POST GAIN 12 Controls the overall volume level of the channel The final level adjustment should be made after the desired sound has been achieved BOTTOM 13 An active tone control shelving type 15 dB that varies the low frequency boost or cut NOTE This control is not functional on the Clean channel BODY 14 An active tone control peak notch 15dB that varies the mid frequency boost or cut NOTE This control is not fuctional on the Clean channel EDGE 15 An active tone control shelving type 15 dB that varies the high frequency boost or cut NOTE This contr
23. i n A Este s mbolo tiene el prop sito de alertar al usuario de la presencia de instrucciones importantes sur l utilisation et l entretien service de l appareil dans la litt rature accompagnant le produit Ce symbole est utilis pour indiquer l utilisateur la pr sence l int rieur de ce produit de tension non isol e dangereuse pouvant tre d intensit suffisante pour constituer un risque de choc lectrique ATTENTION Risques de choc lectrique NE PAS OUVRIR ATTENTION Afin de r duire le risque de choc lectrique ne pas enlever le couvercle Il ne se trouve l int rieur aucune piece pouvant tre r par e par l utilisateur Confier l entrctien un personnel qualifi AVERTISSEMENT Afin de pr venir les risques de d charge lectrique ou de feu n exposez pas cet appareil la pluie ou l humidit Avant d utiliser cet appareil lisez les avertissements suppl mentaires situ s dans le guide d utilisation A Ce symbole est utilis pour indiquer l utilisateur qu il ou qu elle trouvera d importantes instructions A Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen die Handhabung und Wartung des Produkts betreffen Dieses Symbol soll den Anwender vor unisolierten gef hrlichen Spannungen innerhalb des Geh uses warnen die von Ausreichender St rke sind um einen elektrischen Schlag verursachen zu k nnen VORSICHT Risiko Elektrischer Schlag Nicht ffnen
24. l property or tangible personal property allegedly caused by Peavey s negligence Peavey does not assume liability for personal injury or property damage arising out of or caused by a non Peavey alteration or attachment nor does Peavey assume any responsbility for damage to interconnected non Peavey equipment that may result from the normal functioning and maintenance of the Peavey equipment UNDER NO CIRCUMSTANCES WILL PEAVEY BE LIABLE FOR ANY LOST PROFITS LOST SAVINGS ANY INCIDENTAL DAMAGES OR ANY CONSE QUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES THESE LIMITED WARRANTIES ARE IN LIEU OF ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IM PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE PROVIDED HOWEVER THAT IF THE OTHER TERMS AND CONDI TIONS NECESSARY TO THE EXISTENCE OF THE EXPRESSED LIMITED WARRANTIES AS HEREINABOVE STATED HAVE BEEN COMPLIED WITH IMPLIED WARRANTIES ARE NOT DISCLAIMED DURING THE APPLICABLE ONE YEAR OR NINETY DAY PERIOD FROM DATE OF PURCHASE OF THIS PRODUCT SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THESE LIMITED WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STA
25. ler die tiefe mittlere und hohe Frequenzen entsprechend regeln PRE GAIN 7 Regelt die Eingangsempfindlichkeit des Kanals POST GAIN 8 Regelt die Gesamtlautst rke des Kanals Die Feineinstellung sollte erfolgen wenn der gew nschte Klang er reicht wurde ULTRA GAIN SWITCH 9 Hebt generell die Lautst rke des Ultra Kanals an Zum Einschalten in die in Position bringen CRUNCH GAIN SWITCH 10 Hebt generell die Lautst rke des Crunch Kanals an Zum Einschalten in die in Position bringen PRE GAIN 11 Regelt die Eingangsempfindlichkeit des Kanals POST GAIN 12 Regelt die Gesamtlautst rke des Kanals Die Feineinstellung sollte erfolgen wenn der gew nschte Klang er reicht wurde BOTTOM 13 Ein aktiver Klangregler shelving Type 15 dB der die tiefen Frequenzen anhebt oder absenkt MERKE Dieser Regler wirkt nicht auf dem Clean Kanal BODY 14 Ein aktiver Klangregler peak notch 15 dB der die Mittenfrequenzen anhebt oder absenkt MERKE Dieser Regler wirkt nicht auf dem Clean Kanal EDGE 15 Ein aktiver Klangregler shelving Type 15 dB der die hohen Frequenzen anhebt oder absenkt MERKE Dieser Regler wirkt nicht auf dem Clean Kanal REVERB LEVEL 16 Eingebautes Echo Hall System In Uhrzeigerrichtung drehen um den Effekt zu verst rken Fernbedienungs Fufischalter zum Ein und Ausschalten des Effekts MASTER LEVEL 17 Regelt die Gesamtlautst rke des Ger ts Wenn die gew nschte B
26. nde le volume global du canal Le r glage final de niveau doit tre effectu apr s avoir obtenu le sonorit d sir e l aide des autres r glages BOTTOM Grave 13 Bouton de r glage de tonalit actif type passe bas 15 dB faisant varier la coupure ou l amplification des fr quences graves NOTE Cette commande ne fonctionne pas sur le canal Clean BODY Corps 14 Bouton de r glage de tonalit actif correction 15 dB faisant varier la coupure ou l amplification des fr quences moyennes NOTE Cette commande ne fonctionne pas sur le canal Clean EDGE Aigu 15 Bouton de r glage de tonalit actif type passe haut 15 dB faisant varier la coupure ou l amplification des fr quences graves NOTE Cette commande ne fonctionne pas sur le canal Clean REVERB LEVEL 16 La r verb ration est un effet d cho Tournez dans le sens du mouvement des aiguilles d une montre pour augmenter l intensit de l effet Linterrupteur au pied peut contr ler la mise en circuit ou hors circuit On Off MASTER LEVEL Niveau principal 17 Contr le le niveau de volume global du syst me Une fois la balance des canaux Clean Crunch et Ultra tablie le volume du syst me entier peut tre hauss ou diminu l aide de la commande Master Level STATUS LED DEL t moin 18 S allume lorsque l ampli est en mode d attente Standby pour indiquer que l amplificateur n est pas op rationnel
27. nuicion de frecuencias bajas NOTA Este control no funciona en el canal Limpio REVERB LEVEL 16 La reverberaci n es un efecto de eco Haga girar a la derecha para aumentar el efecto El encendido apagado on off se puede controlar con el pedal interruptor de control remoto MASTER LEVEL Nivel maestro 17 Controla el nivel de volumen global del sistema Una vez que se logra el balance deseado de los canales clean crujido y ultra el nivel del sistema entero puede aumentarse o disminuirse con el control de nivel maestro STATUS LED LED indicador de condici n 18 Se ilumina cuando el amplificador est en la condici n de espera standby indicando que el amplificador no est en funcionamiento POWER LED LED indicador de corriente 19 Se ilumina cuando el amplificador recibe corriente alterna STANDBY SWITCH Interruptor de condici n de espera 20 Este interruptor le permite a su aparato estar en condici n de espera o la condici n de activo En la condi ci n standby los tubos permanecen calientes pero el amplificador no est en operaci n POWER SWITCH Interruptor de corriente 21 Oprima el interruptor a la posici n hacia dentro encendido La luz roja del piloto indicador se encender indicando que la unidad est recibiendo corriente alterna EFFECTS PREAMP SPEAKER OUTPUTS e RISK OF ELECTRIC SHOCK 50 60 Hz DO NOT OPEN 200 WATTS MAIN S DO
28. ol is not functional on the Clean channel REVERB LEVEL 16 Reverberation is an echo effect Rotate clockwise to increase the effect Remote footswitch can control On Off MASTER LEVEL 17 Controls the overall volume level of the system Once a desired balance of the Clean Crunch and Ultra chan nels is achieved the entire system level may be increased or decreased with the Master Level Control STATUS LED 18 Illuminates when amp is switched to standby indicating amplifier is not operational POWER LED 19 Illuminates when AC power is being supplied to the amp STANDBY SWITCH 20 Allows amp to be placed in standby or active mode In standby mode the tubes remain hot but the amplifier is not operational POWER SWITCH 21 Depress the switch to the On position The red pilot light LED will illuminate indicating power Is being supplied to the unit BACK PANEL EFFECTS PREAMP SPEAKER OUTPUTS A A s 00 9 RISK OF ELECTRIC SACCK EO DO HOT OPEN A g AUX AVIS RISQUE DE CHOC 8 OHMS 4 OHMS ELECTRIQUE NE PAS OUVRIR 120 VAC SEND dla d REMOTE SWITCH 60 H2 50 W RMS 22 V RMS 200 WATTS EFFECTS PREAMP SPEAKER OUTPUTS eee AVIS RISQUE DE cuoc ELECTRIQUE NE PAS OUVRIR 120 VAC SEND RETURN OUT REMOTE SWITCH 60 Hz 120 W RMY 31 V RMS 200 WATTS A A CAUTION RISK OF FLECTRIC SHOCK DC HOT OPEN 22 28 23 24 25 26 27 GROUND SWITCH 22 Three position rocker type switch which in most applications
29. s curit nous avons incorpor un c ble d alimentation secteur 3 fils avec mise terre appropri e Il n est pas recommand d enlever la broche de mise terre en aucune circonstance S il est n cessaire d utiliser l quipement sans mise terre appropri e utilisez des adaptateurs de mise terre convenables Une bonne mise terre amoindrit le bruit de fond et r duit grandement les risques de choc DEUTSCH Siehe diagramm der frontplatte im englischen teil des handbuchs HIGH GAIN INPUT 1 Dieser Eingang kann f r die meisten elektrischen Gitarren verwendet werden Er ist 6 dB empfindlicher als der Low Gain Input LOW GAIN INPUT 2 Dieser Eingang ist f r die Instrumente vorgesehen die ein besonders hohes Ausgangssignal erzeugen Falls beide Eing nge gleichzeitig benutzt werden sind die Ausgangssignale gleich beide sind dann Low Gain CLEAN GAIN 3 Regelt die Lautst rke des Kanals BRIGHT SWITCH 4 Bringt einen voreingestellten Boost der hohen Frequenzen Zum Einschalten den Schalter in die in Position bringen Die Bright Funktion wirkt nur auf den Clean Kanal CHANNEL SELECT SWITCH 5 W hlt den Ultra oder Clean Kanal an Die Out Position w hlt Clean an MERKE Kanalwahl kann ebenfalls per Fu schalter erfolgen Ist dies gew nscht mu der Schalter sich in der in Position Ultra befinden LOW MID amp HIGH EQ 6 Hierbei handelt es sich um passive Klangreg
30. se 2 Nominal Level clean channel 20 Hz to 20 kHz unweighted Greater than 74 dB below rated power Special noise gate circuitry for Ultra amp Crunch Equalization clean channel only Custom Low Mid amp High passive type EQ Push Bright 6 dB 2 2 kHz Voicing Ultra and Crunch channels only Active Bottom Body and Edge EQ Push Gain Increases gain in Ultra and Crunch channels TONE SETTINGS ADJUST TO TASTE GAIN SWITCH IN HIGH LOW CLEAN GAIN VITRE AREE Ze RER UP SAMEN erre REVERB MASTER Td S h STANDBY POWER HT LLETRA AIN rium i GAIN GAIN 4 5 EN Ds Ip t 5 Tra eo A f 3 e PEET 2 MADE INUSA OFF ADJUST TO TASTE GAIN SWITCH OUT ADJUST TO TASTE CLEAN METAL MILD DISTORTION BRIGHT SWITCH IN GAIN SWITCH OUT Z HIGH LOW CLEAN GAIN A EQUALIZATION 47 CRUNCH SANT AT ULTRA GAIN 47 OCING REVERB MASTER STANDBY POWER GAIN GAIN WA Str driumph ACIONA OI OG eae 5 MAGE NL SA e CI INPUTS BOTTOM BODY FDGF LEVEL POWER ADJUST TO TASTE GAIN SWITCH OUT ADJUST TO TASTE COUNTRY CLEAN COUNTRY ROCK LEAD MILD RHYTHM DISTORTION Tone settings given are general and will vary according to type of guitar type and gauges of strings tyoe of pickup and even type of pick Personal taste playing style and type of music greatly contribute to desired tonality BLOCK DIAGRAM EFFECTS SEND INPUT F SWITCH EFFECTS CHANNELS
31. tions exclusions and limitations hereinafter set forth CONDITIONS EXCLUSIONS AND LIMITATIONS OF LIMITED WARRANTIES These limited warranties shall be void and of no effect if a The first purchase of the product is for the purpose of resale or b The original retail purchase is not made from an AUTHORIZED PEAVEY DEALER or c The product has been damaged by accident or unreasonable use neglect improper service or maintenance or other causes not arising out of defects in material or workmanship or d The serial number affixed to the product is altered defaced or removed In the event of a defect in material and or workmanship covered by this limited warranty Peavey will a In the case of tubes or meters replace the defective component without charge b In other covered cases e cases involving anything other than covers footswitches patchcords tubes or meters repair the defect in material or workmanship or replace the product at Peavey s option and provided however that in any case all costs of shipping if necessary are paid by you the purchaser THE WARRANTY REGISTRATION CARD SHOULD BE ACCURATELY COMPLETED AND MAILED TO AND RECEIVED BY PEAVEY WITHIN FOURTEEN 14 DAYS FROM THE DATE OF YOUR PURCHASE In order to obtain service under these warranties you must a Bring the defective item to any PEAVEY AUTHORIZED DEALER or AUTHORIZED PEAVEY SERVICE CENTER and present therewith the ORIGINAL PROOF OF PURCHASE suppli