Home

Patton electronic SMART-DTA 07MSDTA-QS User's Manual

image

Contents

1. Smart DTA Quick Start Guide Copyright statement Copyright O 2007 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics assumes no liability for errors that may appear in this document Trademarks statement The term Smart DTA is a trademark of Patton Electronics Company All other trademarks presented in this docu ment are the property of their respective owners Warranty For warranty information refer to the Smart DTA Getting Started Guide located on the CD ROM that came with your IAD or available online at www patton com In accordance with the requirements of council directive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling 12 Smart DTA Quick Start Guide
2. the Smart DTA RJ 45 Ethernet WAN port labeled ETH see figure 1 to an Ethernet hub or switch on the same network as your PC The Ethernet WAN interface is configured as a DHCP dient DHCP Server Ethernet Hub or Switch Figure 1 Connecting the Smart DTA to the network via a hub or switch Smart DTA Quick Start Guide 3 3 0 Connect the Smart DTA to an ISDN phone 1 Using a straight though cable terminated with RJ 45 connectors connect the BRI port of your Smart DTA to the S T port of your ISDN phone as shown below RJ 45 male RJ 45 male Y 3 4 5 5 6 6 Note Other pins are not used 4 Smart DTA Quick Start Guide 4 0 Start the SmartNode Discovery Tool 1 Insert the CD included with your Smart DTA into the CD drive on your PC 2 Copy the file named SNDiscovery exe from the CD to your PC gt SmartNode Discovery Tool E x Available SmartNodes IP Address MAC Address 10 10 22 137 D0 40 B4 01 D4 D9 S DTA EUI R3 20 2006 03 30 SIP Double click an entry to get to the Web interface Right click on an entry to see additional connection options 3 At your PC double click the SNDiscovery exe file name to activate the tool The SmartNode Discovery Tool window will display the IP Address MAC Address Device Type model number and Build software release of your Smart DTA If your Smart DTA does not appear e Make sure the Smart DTA and
3. PE PATTON T T ElectronicsTo SmartDTA ISDN VoIP Telephone Adapter Quick Start Guide CE Smart DTA ISDN VoIP Telephone Adapter Important This is a Class A device and is intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment Caution This device is not intended nor approved for connection to the public ISDN telecommuni cation network Attention Ce dispositif n est pas pr vu ni approuv pour le raccordement au r seau de t l communication public le RNIS Vorsicht Dieses Ger t ist nicht f r Anschaltung an das ffentlich ISDN Telekommunikationsnetz genehmigt Precauci n Este dispositivo no est previsto ni se ha aprobado para la conexi n a la red de telecomunicaciones p blica ISDN Attenzione Questo dispositivo non inteso n non approvato per collegamento alla rete di telecomunicazione pubblica ISDN Document Number 13228U7 001 Rev B Sales Office 1 301 975 1000 Part Number 07MSDTA QS Technical Support 1 301 975 1007 Revised July 23 2007 E mail support patton com WWW www patton com AC WARNING The Smart DTA contains no user serviceable parts The equipment shall be returned to Patton Electronics for repairs or repaired by qualified service personnel Mains Voltage Do not open the case the power cord is attached The external power adaptor shall be a listed limited power
4. ith your Smart DTA device and available online at www patton com manuals For detailed information about Installing configuring operating and troubleshooting e Warranty trademark 8 compliance The CD ROM also includes many freeware and shareware tools including TFTP servers and Telnet clients A O Customer and Technical Support Toll Free VolP support call sip support patton com with a VolP SIP dient Online support www patton com E mail support support patton com answered within 1 business day Telephone support Standard 1 301 975 1007 USA Monday Friday 8 00 am to 5 00 pm EST 1300 to 2200 UTC GMT Alternate 41 0 31 985 25 55 Switzerland Monday Friday 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT Fax 1 253 663 5693 USA or 41 0 31 985 25 26 Switzerland Smart DTA Quick Start Guide 7 B O Appendix Factory default IP addresses Factory default IP addresses and netmask configuration WAN interface Ethernet 0 0 0 DHCP Client n a LAN interface Ethernet 1 0 1 192 168 1 1 255 255 255 0 DHCP server address range LAN 192 168 1 10 192 168 1 99 255 255 255 0 C O Compliance Information C 1 Compliance EMC Compliance FCC Part 15 Class A EN55022 Class A EN55024 Safety Compliance IEC 60950 1 EN60950 1 C 2 Radio and TV interference The Smart DTA router generates and uses radio frequency energy and if not installed and used pr
5. nications terminal equip ment and the mutual recognition of their conformity The safety advice in the documentation accompanying the products shall be obeyed The conformity to the above directive is indicated by the CE sign on the device The signed Declaration of Conformity can be downloaded from www patton com certifications C 4 EG Konformit tserkl rung see section C 3 EC Declaration of Conformity for English version Produktbezeichnung Smart DTA Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausf hrung mit den Vorschriften fol gender Richtlinie berein R amp TTE 1999 5 EG Richtlinie des europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Funkanlagen und Telekommunikations Endeinrichtungen und die gegenseitige Anerkennung ihrer Konformit t Die Konformit t mit der oben erw hnten Richtlinie wird durch das CE Zeichen auf dem C Die Sicherheitshinweise in der mitgelieferten Produktdokumentation sind zu beachten Ger t best tigt Die unterzeichnete Konformit tserkl rung kann heruntergeladen werden von ww w patton com certifications C 5 Authorized European Representative DRM Green European Compliance Services Limited Oakdene House Oak Road Watchfield Swindon Wilts SN6 8TD UK Smart DTA Quick Start Guide NOTES Smart DTA Quick Start Guide NOTES
6. operly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Smart DTA router have been tested and found to comply with the limits for a Class B computing device in accordance with specifications in Subpart B of Part 15 of FCC rules which are designed to provide rea sonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Smart DTA router does cause interference to radio or television reception which can be determined by disconnecting the unit the user is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 8 Smart DTA Quick Start Guide C 3 EC Declaration of Conformity See section C 4 EG Konformit tserkl rung for German version Product Description Smart DTA The products described above in the form as delivered are in conformity with the provisions of the following European Directive R amp TTE Directive 1999 5 EC Guidelines of the European Parliament and the Committee for the Harmonization of the Lego Regu lations of the Member States concerning radio equipment and telecommu
7. source that incorporates a disconnect device and shall be positioned within easy reach of the operator The mains outlet shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker The Smart DTA is not shipped with power cables For AC powered units ensure that the power cable used meets all applicable stan dards for the country in which it is to be installed and that it is con nected to a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardless of whether power to the Smart DTA is ON or OFF To avoid electric shock use caution when near WAN ports when detaching the cables detach the end away from the Smart DTA first Do not work on the system or connect or disconnect cables during periods of lightning activity 1 0 Power up the Smart DTA the Smart DTA Take proper measures to ensure that it is not permanently fastened to N The terminal block header to which the wires are secured provides the disconnect for the receptacle mounted on the chassis CAUTION 1 Connect the Smart DTA to a power source using the included power supply and cable 2 When the Power LED stops blinking and remains lit the Smart DTA is ready to configure Smart DTA Quick Start Guide 2 0 Connect the Smart DTA to your local network You must connect the Smart DTA to an IP network that provides a DHCP server Using the included black Ethernet cable connect
8. t DTA home page 6 0 Configuring your Smart DTA Once you have logged in you can use the browser hased graphical user interface GUI to configure and manage your S DTA The Smart DTA home page displays three Immediate Actions buttons that allow you to store the cur rent configuration state reload the device and restore to factory defaults The home page also displays certain basic system information You can always return to the home page by dicking Home in the navigation bar 6 Smart DTA Quick Start Guide The GUI consists of the following main elements The Navigation Bar on the left edge presents you with a menu listing giving access to the various configura tion and status pages of the Smart DTA At the top of the page you see the Current System Path which displays the location and element currently presented in the main area The rest of the page displays the configuration and status information for the different features of the Smart DTA changes Howver your new settings ARE NOT PERMANENTLY SAVED in non volatile memory RAM To survive power failure or manual reload you must store your new IMPORTANT settings in non volatile memory To save your changes return to the home page and press the Save Current Configuration button Whenever you modify the configuration your Smart DTA immediately applies your 7 0 Additional Information Refer to the Smart DTA Getting Started Guide located on the CD ROM shipped w
9. your PC are on the same routed subnet e Make sure any firewall programs on your PC are disabled 5 0 Access the Web Browser GUI Interface 1 In the SmartNode Discovery Tool window select the line that displays the IP address of your Smart DTA gt SmartNode Discovery Tool xl Available SmartNodes IP Address R3 20 2006 03 30 SIP Copy IP to clipboard Figure 2 SmartNode Discovery Tool window Smart DTA Quick Start Guide 2 Right dick the selected line and select Webbrowser The Login window will display Connect to smart node xl f FA 1 o 22H Configuration Access User name administrator hd Password Remember my password cos Figure 3 Login window 3 Enter the username administrator Do not enter a password Instead simply click OK Your web browser will display the Smart DTA home page BE Earrow 10 10 22 137 Home mE Aancca cu PATTON Zz Tlectronics To TEM Network WAN Firewall Smartilode C DNS DynDNS Model S DTA EUI m Telephony Serial Humber 0040B401D4D9 r SIP Hardware Version 2 1 c ISDN Software Version R3 20 2006 03 30 SIP Call Services Q Codecs System Time Thu 01 Jan 1970 19 34 54 GMT Various The system is up for 0 days 19 hours 34 minutes 54 seconds System 4 o Time Immediate Actions Q Support Save Current Configuration Save Reload Reload Read About Restore Factory Defaults License Patton Electronics Company Figure 4 Smar