Home

Patton electronic 2620 User's Manual

image

Contents

1. lectronics vo IPLink Model 2603 amp 2620 WAN Access Router Quick Start Guide Model 2603 ipLink Gateway High Speed WAN Access Router ae Ethernet Model 2603 outer 2620 DiamondLink 1 E1 R St Ton Model ot eo of amp gt S a oS We Ss Ss lt r Model 2620 Document Number 03323U7 001 Rev Sales Office 1 301 975 1000 Part Number 07M2620 QS Technical Support 1 301 975 1007 Revised October 4 2005 E mail support patton com WWW www patton com A WARNING A CAUTION The IPLink 2603 2620 contains no user serviceable parts The equip ment shall be returned to Patton Electronics for repairs or repaired by qualified service personnel An approved external power supply that incorporates a disconnect device shall be used and positioned within easy reach of the operator For AC powered units the power cable used to connect the power supply shall meet all applicable standards for the country in which it is to be installed and be connected to a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardless of whether power to the unit is ON or OFF To avoid electric shock use caution when near WAN ports When detaching the cables detach the end away from the 2603 2620 first Do not work on the system or connect or disconnect cables during periods of lightning act
2. t practical the telephone com pany will notify the customer as soon as possible Also you will be advised of your right fo file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment for repair or warranty information please contact our company If the equipment is causing harm to the telephone network the telephone company may request that you discon nect the equipment until the problem is resolved IPLink 2603 amp 2620 Quick Start Guide 7 Connection to party line service is subject to state tariffs Contact the state public utility commission public ser vice commission or corporation commission for information B 4 Industry Canada Notice This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is con firmed by the registration number The abbreviation IC before the registration number signifies that registra tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment This Declaration of Conformity means that the equipment
3. such as Internet Explorer or Netscape browser 1 At your PC open a web browser and enter the IP address you assigned to the IPLink s Ethernet LAN port in step 2 of section 2 2 Modifying the IP address on page 4 2 Log in to the web management home page using the username superuser and the password superuser Patton Electronics Company 2603 Single Port Router Software Revision 2 4 3 May 25 2005 Status of 2603 Single Port Router Local IP Address 192 168 200 217 CPU Usage 1 NP CPU Usage 1 Up Time 6 days 19 hours Current Time Wed 07 Jan 2004 14 09 47 zZ a Z 25 Z Oo 2 A Copyright c 2004 Patton Electronics Co Terms and conditions Figure 3 IPLink web management home page 3 Now you can use the IPLink s web management pages to complete your configuration see section 6 0 Complete the installation on page 6 5 0 Connect the WAN port The IPLink 2603 T 2603 K and 2620 come with a T1 E WAN interface presented on an RJ 48C connector with selectable line impedances of 100 ohms for 1 and 120 ohms for E1 lines The Model 2603 has one RJ 48C connector and the 2620 has two The Model 2603 K and 2620 KK also come with dual BNC connectors for alternate connection to unbalanced 75 ohm E1 lines To connect the WAN port a Model 2620 Model 2603 7 or if you plan to use the RJ 48C port on a 2603 K refer to section C
4. abled lt ethl gt Transport 2 Modify the IP address for the LAN port according to your network requirements gt ip set interface ipl ipaddress 10 10 10 5 255 255 255 0 Note The above IP address 10 10 10 5 24 is only an example You must choose an IP address on the same subnet as your 3 Verify the new address is correct and save it in system boot memory gt ip list interfaces lt enter gt system config save lt enter gt Now you can connect the IPLink to your local IP network and complete the remaining configuration from your PC using a standard web browser 3 0 Connect to the local IP network Connect the IPLink s green Ethernet port to the same Ethernet segment as your PC see figure 2 Note The Model 2620 does not have an MDI X switch so you must use a cable wired straight through to con nect the Model 2620 s Ethernet port to the IP network If you have a Model 2603 press the MDI X switch until the Ethernet Link LED turns on Connect to Ethernet port Ethernet port MDI X switch Figure 2 Connecting the IPLink to the local IP network Model 2603 K shown IPLink 2603 amp 2620 Quick Start Guide You can check the network connection with the ping command For example you would ping 10 10 10 5 from your PC 4 0 Log onto the web management interface You will now access the web management Graphical User Interface GUI to configure the IPLink using a stan dard web browser
5. al on the IPLink 1 4 Power up indication The Power LED blinks as the IPLink is powering up When the Power LED stops blinking and remains lit the IPLink is ready for you to configure 2 0 Configure the IP address The IPLink is shipped with a factory configured IP address assigned to the Ethernet LAN port green outline The address is 192 168 200 10 24 most cases you must change the address to be on the same subnet as your PC as described in the procedures below If you are not sure which IP address to use for your installation contact your network administrator 2 1 Connecting a PC and logging in 1 Using the included combination RS232 Ethernet cable and DB9 RJ45 adapter connect serial to the IPLink s Console port see figure 1 22 PC with on terminal emulator lt port 9 Connect to Console port Figure 1 Connecting IPLink to the PC s serial port 2 Start a HyperTerminal session on the PC using the settings 9600 bps 8 data bits 1 stop bit no parity no flow control 3 Log in to the IPLink using the factory default login and password Login superuser Password superuser Login successful IPLink 2603 amp 2620 Quick Start Guide 3 2 2 Modifying the IP address 1 Display current interface settings for the IPLink Ethernet LAN port gt ip list interfaces lt enter gt IP Interfaces ID Name IP Address DHCP 1 apl 192 168 200 10 dis
6. ear in this document Trademarks statement The term IPLink is a trademark of Patton Electronics Company All other trademarks presented in this document are the property of their respective owners Warranty Trademark amp Compliance Information For warranty trademark and compliance information refer to the Models 2603 2621 and 2635 IPLink Series High Speed Routers User Guide located on the CD ROM that came with your router or available online at www patton com Electrical and Electronic Equipment WEEE ensure that at end of life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling sd In accordance with the requirements of council directive 2002 96 EC on Waste of 8 IPLink 2603 amp 2620 Quick Start Guide
7. ee VolP support call sip support patton com with a VolP SIP phone Online support www patton com E mail support support patton com answered within 1 business day Telephone support e Standard 1 301 975 1007 USA Monday Friday 8 00 am to 5 00 pm EST 1300 to 2200 UTC GMT Alternate 41 0 31 985 25 55 Switzerland Monday Friday 8 00 am to 5 00 pm CET 0900 to 1800 UTC GMT Fax 1 253 663 5693 USA or 41 0 31 985 25 26 Switzerland 6 IPLink 2603 amp 2620 Quick Start Guide Compliance Information B 1 Radio and TV Interference FCC Part 15 This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television recep tion This equipment has been tested and found to comply with the limits for a Class A computing device in accor dance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the equipment causes interference to radio or television reception which can be determined by disconnecting the cables try to correct the interference by one or more of the fol lowing measures moving the computing equipment away from the receiver re orienting the rece
8. iving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches B 2 EC Declaration of Conformity Product Description IPLink 2603 2620 We certify that the apparatus identified above conforms to the requirements of Council Directive 1999 5 EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equip ment and the mutual recognition of their conformity The safety advises in the documentation accompanying the products shall be obeyed The C conformity to the above directive is indicated by the CE sign on the device The signed Declaration of Conformity can be downloaded from www patton com certifications B 3 FCC Part 68 ACTA Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other information a product identifier in the format US AAAEQ TXXXX If requested this number must be provided to the telephone company The method used to connect this equipment fo the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn
9. ivity 1 0 Power up the router The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage current anticipated temperature flam mability and mechanical serviceability Your router comes with one of the following power supply options External AC adaptor with included power cord Internal AC power supply Internal DC power supply no power accessories are included 1 1 Models with external AC adaptor 1 Connect female plug of the AC power cord to the AC adaptor provided 2 Connect the barrel type connector of the AC adaptor to the barrel type Power jack on the IPLink router 3 Insert the male plug of the AC power cord into an AC power outlet 100 240 VAC 1 2 Models with internal AC power supply 1 Insert the female end of the AC power cord into the internal power supply connector 2 Connect the male end of the power cord into an AC power outlet 100 240 VAC IPLink 2603 amp 2620 Quick Start Guide 1 3 Models with internal DC power supply 1 Strip insulation 1 4 inch from the electrical wires that will connect the DC power source to the IPLink 2 Connect the ground terminal from the power source to the ground terminal on the IPLink 3 Connect the negative terminal from the power source with to the negative terminal on the IPLink 4 Connect the positive terminal from the power source with to the positive termin
10. meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the ground connections of the power utility telephone lines and internal metallic water pipe system are connected together This protection may be particularly important in rural areas Copyright statement Copyright 2005 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics assumes no liability for errors that may app
11. onnecting to the RJ 48C WAN port Otherwise refer to section Connecting to the unbalanced 75 ohm TX and RX WAN ports Model 2603 K and 2620 KK only to install cables onto the BNC connectors on the 2603 K and 2620 KK models IPLink 2603 amp 2620 Quick Start Guide 5 Connecting to the RJ 48C WAN port 1 Obtain a twisted pair cable with an RJ 48C plug connector at each end 2 Plug one end of the cable into the RJ 48C socket labeled WAN on the IPLink Router 3 Plug the other end of the cable into the T1 E1 device 4 Repeat steps 1 through 3 to install the remaining WAN cables on a Model 2620 Connecting to the unbalanced 75 ohm TX and RX WAN ports Model 2603 K and 2620 KK only 1 Obtain a coaxial cable with a BNC connector at each end 2 Plug one end of the cable into the transmit socket labeled TX on the IPLink Router Plug the other end of the cable into the receive port of the device 3 Plug one end of the cable into the receive socket labeled RX the IPLink Router Plug the other end of the cable into the transmit port of the E1 device 6 0 Complete the installation To finish configuring your IPLink and for detailed information about installing configuring operating and trou bleshooting refer to the Models 2603 2621 and 2635 IPLink Series High Speed Routers User Guide and appli cation notes available on the enclosed Patton CD ROM or at www patton com A O Customer and Technical Support Toll Fr

Download Pdf Manuals