Home
Panasonic CZ-RD516C Installation Manual
Contents
1. Co Ltd or equivalent Secure the remote controller lower case to the outlet box with the two accessory screws 3 Make sure that the lower case is flat against the wall at this time with no bending Pass the remote controller cable 2 into the box Route the remote controller cable 2 inside the lower case through rear feeding out direction Insert firmly the connector of remote controller cable 2 to connector CON1 in the upper case circuit board Refer to the illustration at below Secure the remote controller upper case to the lower case with the tabs provided Avoid installing the remote controller cable near refrigerant pipes or drain pipes else will cause electrical shock or fire Install the remote controller cable at least 1 31 32 5cm away from electric wires of other appliances to avoid miss operation electromagnetic noise o Be sure to use only the accessory screws to avoid damage of remote controller PCB ATTACHED ACCESSORIES ef we fo eom Ramee Upper tab Remote controller 1 Remote controller cable ne Length 32 5ft 9 9m Connector CON1 Screw Lower case i Installing the remote controller to an outlet box M4 machine pitched 1 3 16 3 30mm embedded cable Screw W B Screw Installing the remote controller to the wall L ii M4 self tapping 9 16 14mm exposed cable eres Remote controller cable holder Ga Holder for remote controller cable at control board Wal
2. Panasonic F614834 XL Wired Remote Controller Installation Manual 1 3 16 30mm 1 3 16 or more Remote controller Remote controller lower case SAFETY PRECAUTIONS Upper case Read the following SAFETY PRECAUTIONS carefully before installation x Electrical work must be installed by a licensed electrician Lower case 4 23 32 The caution items stated here must be followed because these important contents are related to safety The meaning o of each indication used is as below X Incorrect installation due to ignoring of the instruction will cause harm or damage and the seriousness is classified by the following indications Allow sufficient space around the remote controller 1 as shown in the illustration above e N WARNING This indication shows the possibility of causing death or serious injury install in a place which is away from direct sunlight and high humidity Install in a flat surface to avoid warping of the remote controller If installed to a wall with an uneven surface damage AN CAUTION This indication shows the possibility of causing injury or damage to properties only to the LCD case or operation problems may result z ion i is 3 9ft to 4 9f The items to be followed are classified by the symbols T o the LCD can be easily seen for operation Standard height from the floor is 3 9ft to 4 9ft ae O i Symbol with white background denotes item that is PROHIBITED from doing Avo
3. ause electrical shock case or fire 3 Secure the lower case to an outlet box or wall Refer to A or B instructions below depending on your choice of cable Sarew rs fire or electrical shock installation or 4 Be sure to use only the screws provided Screw 4 For electrical work follow the local national wiring standard regulation and this installation instruction Otherwise it will cause the electrical shock or fire 5 Do not over tighten the screws as it may result in damage to Sen the lower case Wire routing must be properly arranged so that control board cover is fixed properly If control board cover is not fixed perfectly it will cause fire or electrical shock If passing the remote controller cable through a wall be sure to install a water trap above the cable Otherwise it will cause the electrical shock Z CAUTION Do not touch the sharp aluminium fin of air conditioner unit during wired remote controller installation sharp parts may Cause injury Install in a flat surface to avoid warping of remote controller else damage to the LCD case or operation problems may result o Use the attached accessories parts and specified parts for installation Otherwise it will cause the set to fall A IF REMOTE CONTROLLER CABLE IS EMBEDDED 1 Embed an outlet box JIS C 8336 into the wall Outlet box may be purchased separately Medium sized square outlet box obtain locally Part No DS3744 Panasonic
4. e controller cable 2 with screw 7 After complete install back removed parts follow reverse procedure No Remote controller cable Note Remote controller cable cannot be extended Control board cover Terminal board FAL cover complete eae Green wire emote controller Front e AAN connector CN RMT and tighten green 8 to the grounding location provided Make sure remote control cable wire not touching to wire connected to terminal board as shown Connector CN RMT Remote controller cable 2 Remote controller cable holder 5 Screw 7 A Remote controller ENGLISH F614834
5. e in accordance with the intended feeding out direction Refer to the illustration at below Insert firmly the connector of remote controller cable 2 to connector CON1 in the upper case circuit board Refer to the illustration at below Secure the remote controller upper case to the lower case with the tabs provided Remote Notches Top feeding out controller position cable 2 Left feeding out position ay Right feeding out Connector Upper case Upper case Lower case Be sure to turn off the main power before installing and connecting the remote controller Otherwise it will cause the electrical shock Open front grille complete Please refer HOW TO TAKE OUT FRONT GRILLE N cover complete Open the control board cover complete and terminal board 3 Connect remote controller cable 2 to remote controller 1 and guide the remote controller cable 2 into the unit through the wire insertion hole 4 Guide the remote controller cable 2 into the remote controller cable holder 5 and tighten with screws 6 Fasten the remote controller cable holder to control board with screw 7 5 Install back terminal board cover complete Be careful not to clamp the cable between terminal board cover and control board 6 Insert firmly the connector of remote controller cable 2 to indoor PCB wire from remot
6. id installing the remote controller cable near refrigerant pipes or drain pipes else it will cause electrical shock or fire O Symbol with dark background denotes item that must be carried out Carry out test running to confirm that no abnormality occurs after the installation Then explain to user the operation care and maintenance as stated in instructions Please remind the customer to keep the operating instructions and installation instruction for future reference 2 INSTALLING THE REMOTE CONTROLLER UNIT TO THE WALL Z WARNING 1 Remove the remote controller 1 lower case Upper case Do not modify the length of the remote controller cable Otherwise it will cause fire or electrical shock Unsen a ial upped T diy 3t0 Sulla tog ee lore Cy 3 mm into one of the gaps at the bottom of the case and twist Be sure to turn off the main power before installing and connecting the remote controller Otherwise it will to open Refer to the illustration at right cause the electrical shock Be careful not to damage the lower case Screw Engage authorized dealer or specialist for installation If installation done by the user is defective it will cause 2 Do not remove the protective tape which is affixed to the upper driver gwareace electrical shock or fire case circuit board when remove the remote controller lower Install according to this installation instructions strictly If installation is defective it will c
7. l Upper case When the wall is hollow please be sure to use the sleeve for remote controller cable to prevent dangers caused by mice biting the cable PRBeeweeueueeuaaseueauaauaasr Outlet box JIS C 8336 Connector Screw CON1 6e M4 machine screw amp washer 1 Tighten remote controller cable with holder controller Upper case 13 32 10mm cable 2 Upper case Screw 3 Ya Installing the remote controller cable to control Saar edie cue L M3 self tapping 5 16 8mm board ene g Lower case Screw x Installing the green wire to terminal board B IF REMOTE CONTROLLER CABLE IS EXPOSED 1 Install the remote controller lower case to the wall with the two accessory screws 4 2 Fasten the screws properly until screw head is lower than the rib and reach the base of remote controller lower case to ensure they do not damage the PCB inside the remote controller Screws Remote controller lower case a SSS Dd SRA OS SSS Se NNSNSSSSSSSNSSSSSSSNNSNS NAN Remote controller cable Upper case Upper tab Connector CON1 Lower case S crews 4 Wu Lower tab The feeding out direction for the remote controller cable can be either via top left or right side Use nipper to cut a notch at the upper case Select the intended feeding out position Route the remote controller cable 2 inside the lower cas
Download Pdf Manuals
Related Search
Related Contents
GE Profile JV696SCC User's Manual User Manual - Adaptive Modules Instructions for Installing Steering Gears User manual - Spicy Guitar Yamaha PSS-390 Owner's Manual SUPER DEGRIPPANT TOUTES POSITIONS WorkCentre PE220 Manual do Usuário Brainboxes US-279 2 1 3 NOHA Norway AS INSTALLATION MANUAL S21/Mod Copyright © All rights reserved.