Home
Oregon Scientific EW96 User's Manual
Contents
1. which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales Please visit our website at www2 oregonscientific com service support for all inquiries We Name Oregon Scientific Inc Address 19861 SW 95th AVe Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 Declare that the product Product No EW96 Product Name Projection Alarm Clock with Indoor Thermometer Manufacturer IPM Concepts Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong is in conformity with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 2009 Oregon Scientific All rights reserved
2. C8314A Size A4 OreGcon SCIENTIFIC Projection Alarm Clock with Indoor Thermometer Model EW96 USER MANUAL Thank you for your purchase of this Projection Alarm Clock Please read these instructions carefully and keep the manual well for future reference The unit has a clear and easy to read display that shows the indoor temperature time and date This product is designed to synchronize its date and time automatically once it is within range of the WWVB 60 signal from the atomic clock in Fort Collins Colorado OVERVIEW RECEIVER 1 Projector e Use it to project the time 2 SNOOZE LIGHT key e In normal time mode press it once to turn on the backlight for 5 seconds e Press it to silence the current alarm when it is going and enter the snooze mode for 8 minutes 3 LCD display e Displays time indoor temperature and date 4 key e In time setting mode press it to increase the setting values 5 SET CLOCK key e In normal time mode press it once to enter the normal time setting mode e In normal time setting mode press it to step the setting items Press and hold it to exit the setting mode in any step 6 key e In time setting mode press it to decrease the setting values 7 DC jack e Plug DC adaptor to power the clock 8 ALARM ON OFF key e Press it once to turn on the backlight and display the alarm time for 5 seconds e Press it again to turn on off the al
3. Colorado When used for the first time after inserting batteries or pressing RESET key the clock will start to search for the atomic clock signal and the signal reception icon will flash for 5 minutes SIGNAL RECEPTION INDICATOR The wave segment flashing means time signals are being received The signal quality could be classified into 3 types e N No signal Weak signal Excellent signal Note The unit will automatically search for the time signal at 2 00am 3 00am or 4 00am is also available if the signal is not received at 2 00am 8 00am 2 00pm and 20 00 each day 2 Always place the unit away from electrical devices such as televisions computers telephones etc 3 Avoid placing the unit on or next to metal plates 4 If possible place the unit next to a window Signal reception is greatly decreased when located in closed areas like basements or metal buildings 5 Do not start reception in moving vehicles or trains TIME AND CALENDAR MANUAL SETTING If you are out of reach of the Radio Controlled sensor or if the reception is not reachable the time and calendar can be set manually As soon as the signal of sensor is received again the clock will automatically synchronize with the exact time and calendar 1 In normal time mode press SET CLOCK key once to enter the time setting mode 2 Press or key to change the settings 3 Press SET CLOCK to confirm The setting
4. arm 9 SET ALARM key e Press it once to turn on the backlight for 5 seconds and press it again to enter the alarm time setting mode e In alarm time setting mode press it to step the setting items 10 FOCUS turning knob e Focus the projected image 11 BATTERY COMPARTMENT e Accommodates 2 AA size batteries 12 RESET key e Press it to return all values to default values e Incase of malfunction the unit may be required to reset 13 C F slide switch e Slide it to switch between Celsius and Fahrenheit 14 PROJECTION ON OFF slide switch e Slide it to turn on off the projector 15 180 FLIP key e Press it to rotate the projected image by 180 16 RCC key e In normal time mode press it once to receive the RC signal for reception testing 17 BATTERY DOOR LCD DISPLAY 1 Time zone 2 Low battery indicator 3 Signal reception indicator 4 Indoor temperature 5 Time 6 Alarm time amp Date EE SESE OPERATING THE MAIN UNIT T Remove the battery door and insert 2 new AA size batteries as per the polarity information marked on the battery compartment 2 Press RESET key to restart the clock 3 Slide C F switch to select between Celsius and Fahrenheit 4 Replace the battery door RECEPTION OF RADIO CONTROLLED TIME SIGNAL The time and calendar are radio controlled The current time and calendar are automatically synchronized with the atomic clock signal from Fort Collins
5. order is 12 24 hr format time time zone offset year day month format date 4 Press SET CLOCK key to save and exit the setting mode o oo 78 a toe os 64l P 12 24 Hr setting Time setting Time zone setting ue oe eT Ht JL Ba ees Month Date setting MD DM setting Year setting Note i2 During the setting period press and hold or key to speed up the change of settings 2 The time zone indicators are abbreviated as below P Pacific M Mountain C Central E Eastern ALARM TIME SETTING il In normal time mode press SET ALARM key once to enter the alarm time setting mode 2 Press or key to set hour minute 3 Press SET ALARM key to save and exit the setting mode indicates alarm is ON so oso 184 l225 BeZ Normal time mode Alarm time Setting Note The alarm will be automatically turned on when you set the alarm time During the alarm time setting period press and hold or key to speed up the change of settings USING ALARM FUNCTION Follow the directions above to set the alarm time ny 2 In normal time mode press ALARM ON OFF key once to display the current alarm time 3 Press it again to turn alarm ON OFF TO SILENCE THE ALARM Press SNOOZE LIGHT to silence the alarm for 8 minutes The Q will be flashing 2 Press any other key
6. otice ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products If you re in the US and would like to contact our Customer Care department directly please visit wwwe2 oregonscientific com service support For international inquiries please visit wwwez oregonscientific com about international FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception
7. to turn the alarm off and activate it again after 24 hours 3 If no key is pressed within 120 seconds the alarm will be turned off and be activated again after 24 hours USING THE PROJECTOR Slide the PROJECTION ON OFF switch to turn on off the projection light The projection light must be on a dark background and within 1 4 meters 3 to 12 feet from the clock see example below A 05 ats tt N Sison Sten 1 Slide PROJECTION ON OFF to turn on the projection function 2 Press SNOOZE LIGHT to turn on the projector for 5 seconds 3 When using DC power adapter the projector will be turned on all the time 4 If the alarm is set to go off the alarm icon D will be projected 5 Press 180 FLIP to rotate the projected image by 180 6 Turn FOCUS knob to focus the projected image BATTERY REPLACEMENT If the low battery icon turns on next to time replace the main unit s battery with 2 new AA batteries Low battery indicator Note Attention Please dispose of the used unit or batteries in an ecologically safe manner SPECIFICATIONS TYPE DESCRIPTION MAIN UNIT 138 x 42 x 82 mm Ee 5 43 x 1 65 x 3 23 in Weight 183g Temperature o o range 5 C to 50 C 23 F to 122 F Temperature 0 1 C 0 2F resolution Power 2x AA 1 5V batteries Note We recommend that you use alkaline batteries with this product for longer
8. usage and lithium batteries in temperatures below freezing PRECAUTIONS e Do not subject the unit to excessive force shock dust temperature or humidity e Do not cover the ventilation holes with any items such as newspapers curtains etc e Do not immerse the unit in water If you spill liquid over it dry it immediately with a soft lint free cloth e Do not clean the unit with abrasive or corrosive materials e Donottamper with the unit s internal components This invalidates the warranty e Only use fresh batteries Do not mix new and old batteries e Images shown in this manual may differ from the actual display e When disposing of this product ensure it is collected separately for special treatment and not as normal household waste e Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible Consult the furniture manufacturer s care instructions for information e The contents of this manual may not be reproduced without the permission of the manufacturer e Do not dispose old batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary e Please note that some units are equipped with a battery safety strip Remove the strip from the battery compartment before first use Note The technical specifications for this product and the contents of the user manual are subject to change without n
Download Pdf Manuals
Related Search
Related Contents
Sony 128GB flash User Manual Pyle PylePro PPHP1288A MyDisc User's Manual Cobra Electronics NAV ONE 2200 GPS Receiver User Manual Informazioni sul presente Manuale di Istruzioni User`s Manual Pumps Up - Control Global Copyright © All rights reserved.
Failed to retrieve file