1. MSI Plessey Settings Start End Menu Do not Check 1 CD Check 2 CD s Mod 10 Check 2 CD s Mod 11 Transmit CD1 Do not Check 2 CD s Mod 10 MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable start stop characters Supported characters include numeric digits 0 through 9 The checksum is calculated as the sum modulo 10 or 11 of the data characters The checksum CD2 is calculated as the sum modulo 10 or 11 of the data characters and CD1 String format eee cor om Options for MSI Plessey ii Disable check digit check Selection of the check digit calculation Selection of the number of check digits to be transmitted Page 32 Manual No 25 ULGPMU01 01 Series OPT Handheld CCD Scanner Check digit If the check digit calculation is required then the appropriate calculation method must be selected Do not transmit CD The character positions CD1 and CD2 are not transmitted Transmit CD1 The character position CD2 is not transmitted Transmit CD1 and CD2 All characters in the label are transmitted Page 33 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Code 128 EAN 128 Settings Start End Menu Enable only Enable FNC2 Disable FNC2 me L IN va Disable or 0 11 ANTI I II OG EAN 128 if possible
2. Disable Trigger This is applicable to readers which have a trigger switch When this option is selected the reader will stay ON all the time Multiple Read Reset Time Start End ZZ Program Menu AH 50 ms Al 100 ms AJ 200 ms AK 300 ms AL 400 ms AM 500 ms AN 600 ms ME Multiple Read Reset Time This option can be used in conjunction with multiple read mode It sets the time the reader should be pointed away from the label before it can decode the same label again Page 58 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Quiet Zone Settings ZZ Start End Program Menu YN No margin check YO Margin check 1 7 normal YP Margin check 2 7 normal YQ Margin check 3 7 normal YR Margin check 4 7 normal YS Margin check 5 7 normal YT Margin check 6 7 normal YU Margin check normal ME With these settings the reader can decode bar codes that have smaller start and or end margins than specified for the symbology These settings may increase the possibility of partial and ghost reads hence do not use smaller margin checks than necessary Replace any bar code labels with ones that have the correct start and end margins if possible Page 59 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Read Time Settings
3. Page 61 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Buzzer Settings ZZ Start End Program Menu WR Enable software buzzer WU Disable buzzer WI Single tone buzzer W2 High low buzzer W3 Low high buzzer W7 Buzzer duration 50 msec W4 Buzzer duration 100 msec WS Buzzer duration 200 msec W6 Buzzer duration 400 msec TO Buzzer volume maximum Tl Buzzer volume loud Page 62 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld transmission Buzzer normal Buzzer minimum Buzzer before ME CONTINUED ON NEXT PAGE Page 63 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Buzzer Settings Start End Menu Buzzer transmission Disable buzzer Buzzer Settings These options determine the buzzer type tone duration and loudness By default the buzzer is disabled for Linker type readers Buzzer Type The buzzer may be disabled or enabled as either a hardware of software buzzer Not all readers support both a hardware and software buzzer Buzzer Tone If a software buzzer is used the buzzer tone may be selected Buzzer Duration and Volume If a software buzzer is used a buzzer duration of 50 100 200 or 400 msec may be selected Volume may also be adjusted Buzzer Before Transmission The good rea
4. Page 40 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Suffix Settings ZZ Start End Program Menu GM Matrix 20f5 19 IATA L9 Telepen MSI Plessey UPC A UPC E EAN 13 EAN 8 00 UPC A add on Ol UPC E add on 02 EAN 13 add on 03 EAN 8 add on 04 Code 39 05 Codabar CONTINUED ON NEXT PAGE Page 41 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Suffix Settings continued Start End zz wear III Menu os 55 IN ox 11111 os IUI ov IUI ee 22 MOMIA ps rosonse ez Iu Page 42 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Keyboard Keys ZZ Start End Program Menu 8J Fi 8K F2 8L F3 8M F4 8N FS 80 F6 8P F7 8Q F8 8R F9 8S F10 8T F11 8U F12 9X Backspace 7H TAB CONTINUED ON NEXT PAGE Page 43 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Keyboard Keys continued ZZ Start End Program Menu 71 Carriage return 7Q Enter numeric pad 7R Enter make alpha pad 75 Enter make and break alph
5. Page 53 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Control Characters ZZ Start End Program Menu 9G A NULL 1A NA SOH 1B AB STX 1C AC ETX 1D AD EOT IE E ENQ 1F AF ACK 1G AG BEL 1H AH BS 11 HT 1J AJ LF IK AK VT IL AL FF 1M AM CR CONTINUED ON NEXT PAGE Page 54 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Control Characters continued ZZ Start End Program Menu IN AN SO 10 AO SI IP AP DLE IQ AQ DCI IR AR DC2 1S AS DC3 1T AT DCA 1U AU NAK 1V AV SYN 1W AW ETB 1X AX CAN 1Y AY EM 1Z AZ SUB 9A MESC CONTINUED ON NEXT PAGE Page 55 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Control Characters continued Start End zz a INI Menu seo INI sc nes IU KN oo II se 00 DEL 9F cascar127 PA Direct Input Code ID Length Start End Menu Code Page 56 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Read Mode Settings ZZ Start End Program Menu 50 Single read SI
6. Start End zz ram IND Menu vo III Ya INI v2 o 11 ca ya JIMMIRA ya sxo IMM ys IRI vo IRI yr INI vs sss IRI ve ain 1 11 Read Time Settings the length of the period that the reader is ON after the trigger switch is pressed or in multiple or continuous read mode after a label has been read Selecting a read time of 0 means that the reader will stay ON as long as the trigger switch is being pressed Selecting a read time for readers without a trigger switch or when the trigger switch is disabled has no effect YM Indefinitely Page 60 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Redundant Decoding Settings Start End Menu No Two times xi 22 MMM ga xX Three times Redundancy Settings This is the number of times that a label must be correctly decoded before it is transmitted Selecting a higher redundancy count makes reading slower but it reduces the probability of reading errors especially when labels of poor definition are used Four times X3 redundant Positive and Negative Bar Codes Start End Menu Positive Both positive bar codes Positive and Negative Bar Codes Usually bar codes are printed black on white but sometime white on black These labels are called positive and negative respectively
7. Telepen Settings bici Start End Menu Numeric 9 0 Telepen is a variable length symbology with a check digit and non printable start stop characters Supported characters include numeric digits 00 through 99 in numeric mode and all 128 ASCII characters in full ASCII mode The check digit calculation is derived from the sum of all data characters modulo 127 The check digit cannot be transmitted String format Options for Telepen Selection of full ASCII mode 1 to 32 characters Data Page 37 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Case Conversion Start End Menu No case yz INI Convert to Convert to YY Exchange case String Options This section describes the alterations which can be made to the format of the transmitted data string Options available are x x x Case conversion Transmission of a code identifier Transmission of the code length Transmission of a prefix Transmission of a suffix The prefix and or suffix may include a code identifier and or the code length String format bar code suffix data prefix Case conversion The bar code may be converted to either lower of upper case or the case my be exchanged These options may be used if the user of a wedge has a preference to leave for instance the CAP
8. Page 4 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Part II Installation and SetUp This section of the manual contains information on the physical installation of the scanner as well as certain programming options There is a separate section for each type of interface Check to see which type of interface your scanner has and turn to that section for information on installing the scanner A Installation Keyboard Wedge Interface A Y connection cable is required for installation The scanner is installed or wedged between the keyboard and the computer Your Y cable should have connectors for both a PS2 and AT type installation The Y cable connects both the scanner and the keyboard to the computer The scanner must match the type of computer being used The default setting is for an IBM AT type computer If this type does not match the host computer refer to the Computer Type Selection in the programming section that follows Ifthe connector does not match the host compute remove the short cable section reverse it and insert it in the other connector Page 5 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Reset All Defaults Keyboad Wedge Interface Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers In most applications the scanner will work right out of the box without any need
9. Series OPT Handheld Direct Input Characters continued ZZ Start End Program Menu Q0 Ql Q2 Q3 Q4 6 Q7 Q8 Q9 0A 0B UC CONTINUED ON NEXT PAGE Page 49 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Characters continued ZZ Start End Program Menu 0D D OE OF 0G 0H OI OJ OK OL 0M ON 00 OP 0Q CONTINUED ON NEXT PAGE Page 50 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Characters continued ZZ Start End Program Menu OR R 05 OT 0U OV OW 0X OY UZ SA B C D SE CONTINUED ON NEXT PAGE Page 51 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Characters continued ZZ Start End Program Menu F G H SI SJ K L M N O P Q R S CONTINUED ON NEXT PAGE Page 52 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Characters continued ZZ Start End Program Menu T U V W X Y Z
10. Code 128 is a variable length symbology with a mandatory check digit and non printable start stop characters Supported characters include i All 128 ASCII characters 4 non data function characters 4 code set selection characters 3 start characters and 1 stop character The check is calculated as the sum modulo 103 of the start character and the weighted values of the data and special characters String format data 1 or more characters EAN 128 In this mode the Code 128 data is translated to the EAN 128 format EAN 128 data starts with the FNC1 character and separates 2 data fields with the FNC1 character The first FNC1 character is translated to C1 and the second FNCI character is translated to ASCII GS hex 1D character String format data data ie characters OD characters Enable EAN 128 only In the mode the decoded data characters are translated to the EAN 128 format If the data does not comply with the EAJ 128 format then the label is rejected Enable EAN 128 if possible In this mode the decoded data characters are translated to the EAN 128 format If the data does not comply with the EAN 128 format then the label is transmitted as Code 128 Page 34 Manual No 25 ULGPMU01 01 Series OPT Handheld CCD Scanner FNC2 Concatenation If a Code 128 bar code contains a leading FNC2 character the data is stored into the reader s bu
11. A Page 19 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld EAN 13 and EAN 8 Settings ZZ Start End Program Menu 6K EAN 13 transmit CD 6J EAN 13 do not transmit CD 61 EAN 8 transmit CD 6H EAN 8 do not transmit CD IB Disable ISBN translation IA Enable ISBN translation IK Enable ISBN if possible Disable ISSN translation HO Enable ISSN translation 4V Enable ISSN if possible Page 20 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld EAN 13 and EAN 8 Settings EAN 13 is a fixed length symbology encoding 12 data digits a check digit and non printable start stop characters Supported characters are numeric digits 0 to 9 The data may be translated into ISBN or ISSN format String format data 12 digits check digit EAN 13 add on 2 add on 5 The EAN 13 symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String format data 12 digits check digit add on 2 or 5 EAN 8 is a fixed length symbology encoding 7 data digits a check digit and non printable start stop characters Supported characters are numeric digits 0 to 9 String format data 7 digits check digit EAN 8 add on 2 add on 5 The EAN 8 symbology as described above can be succeeded by an additional 2 or 5 di
12. Lc moya NN LD pes ILL LE pus NN LF payo A LG mans NN IH Day Lm MIET LU TIT LU IK 0 A v la i LU Page 7 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner B Installation RS232 Interface The RS 232 scanner cable is terminated in with a DB9 female connector An external power supply 5V DC may be necessary There is a power supply jack on the RS 232 connector Installation is as follows 1 Plug the scanner into an RS232 serial port such as COMI of the host PC If external power is required insert external power plug into the jack on the RS 232 connector 2 Connect the power supply into an electrical outlet 110 V AC 3 Turn on the power to the host computer Make sure the communication parameters of the computer match those of the scanner The default communications settings are 9600 baud 8 data bits 1 stop bit no parity no handshaking 4 Be sure the PC is in a program such as WordPad that will accept input from the serial port Reset All Defaults RS232 Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers In most applications the scanner will work right out of the box without any need for additional programming At any time you can return the scanner to the factory default settings by scanning the Reset all Defaults programming bar code below Start LL Program Menu II I
13. Multiple read S2 Continuous read Add on wait mode disabled XB Add on wait mode 0 25 sec XC Add on wait mode 0 50 sec XD Add on wait mode 0 70 sec ME Single Read When a bar code has been decoded the reader will be turned OFF The reader must be triggered again to read another label This option and Disable trigger cannot be programmed at the same time Multiple Read When a bar code has been decoded the reader will stay ON for a time as set by read time settings or indefinitely if the trigger switch has been disabled The same label can only be decoded again after the label has not been detected for a number of scans Continuous Read The reader will produce as much data as it can decode regardless whether it is the same or not This mode is mainly used for demonstration and diagnosis Add on Wait Mode Used if UPC EAN with add on is enabled The reader searches within the selected time for a valid add on code If a valid add on code is found the reader transmits the data immediately If nothing is found behind the code the scanner will transmit the data without add on If something is found behind the code the reader ignored the code in case it is not a valid add on Page 57 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Trigger Settings Start End Program Menu ZZ Disable trigger S7 Enable S8 trigger
14. for additional programming At any time you can return the scanner to the factory default settings by scanning the Reset all Defaults programming bar code below NOTE D DA A pointing finger indicates default settings throughout the following menus Start LL Program Menu II II l UA xT Weds I U UB AT Wede UTA IN UC PS wed AMAMI End S e i 0 Computer Type Selection for Keyboard Wedge only The Keyboard Wedge interface scanner is designed to operate with an IBM personal computers and compatibles along with a Macintosh PC s Select the host computer type from the menu below NOTE If the scanner has not been set to the correct host computer the scanner will display random characters on the screen after reading a bar code label Start LT Menu xo are II IBM AT amp xi gt xs meven KIM Ka III End sala 000 Menu Page 6 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Intercharacter Delay for Keyboard Wedge interface The scanner may send data faster than the computer or application program can accept This is called keyboard buffer overrun If data appears to be missing random read errors occur or the scanner locks up and will not scan experiment with the various keyboard timing options listed in the menu to follow zz RT PL LA sone NN LB pi IH
15. numerical values of all the data characters The following 2of5 codes are supported Industrial 2015 1 2015 This symbology encodes a pair of digits in each symbol the number of digits are therefore always an even number Information is carried in the bars and spaces The start and stop pattern in not unique inside the code It is therefore essential to use the fixed length option to prevent partial reads Matrix 20f5 This symbology encodes 1 digit in each character the number of digits can therefore be an odd or an even number Information is carried in the bars and spaces String format Industrial Interleaved or Matrix 2015 leading data 1 or check zero more digits digit Options for Code 2015 Disable transmission of the check digit Enable check digit check Selection of the minimum number of data characters Disable space check for industrial 2015 ii Transmit S Code as Interleaved 20f5 x Minimum data characters Code 2015 are checked for a minimum of 1 3 or 5 characters as set by the user If the number of characters in the label is less than the number set the label will be rejected If the fixed length option is used for a Code 2015 type label then such label will also be checked for fixed length Intercharacter gap check This option enables the reading of Industrial 2015 labels with a large or irregular spacing Page 31 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld
16. the characters or with one of the alpha characters A to Z String format start data 0 or check stop char more characters digit char Options for Code 39 Enable full ASCII conversion M Enable Italian Pharmaceutical conversion Enable check digit Disable transmission of the check digit M Enable transmission of start stop Enable leading A for Italian Pharmaceutical Selection of the minimum number of data characters Normal Code 39 In this mode the decoded data characters are transmitted without further translation Full ASCII Code 39 In this mode the decoded data characters are translated to full ASCII Code 39 Full ASCII Code 39 if possible In this mode the decoded data characters are translated to full ASCII code 39 Invalid combinations are not translated and are transmitted as is Concatenation If a Code 39 bar code contains a leading space the data is stored into the reader s buffer without the leading space As soon as a Code 39 bar code is read without a leading space the data is appended to the reader s buffer and the entire buffer is transmitted and cleared for new data In case a non Code 39 bar code bar is transmitted and the buffer is cleared The buffer size is reader dependant Page 24 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Codabar Settings ZZ Start End Program Menu FO Do not transmit start stop Fl
17. 15 Page 16 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Setting the Number of Characters to be Scanned Start End Menu Fixed length all codes R Fixed length all codes Fixed length selected codes Min length Max length Setting Code Specific Options Options for specific codes may be configured affecting Enabling and disabling code variants and translations Data verification such as by mean of a check digit calculation A check digit has a value that can be calculated from the other data characters and is usually the last data character in a bar code Pre editing of the data string such as removing the check digit and or ST SP characters The more common options are described here Check CD Enables the check digit calculation If the calculated check digit does not correspond to the check digit in the bar code then the bar code is ignored The use of a check digit greatly improves the security of a bar code Do Not Check CD Disables the check digit calculation This option is required when the bar codes do not contain a check digit or contain an invalid check digit Transmit CD Enables the transmission of the check digit together with the data characters If the check digit calculation is disabled the reader cannot differentiate anymore between a valid check digit and a data character It will therefore transmit all data characters of the label in
18. No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Codabar Settings continued ABC Code The ABC code is an acronym for American Blood Commission The code consists of two bar codes which are decoded in one read cycle the code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D These two D s are not transmitted String format start data 1 check data 1 check stop char chars digit chars digit char CX Code The CX Code consists of two are codes which are decoded in one read cycle The code is concatenated when the stop character of the first bar code is a C and the start character of the second bar code is a B The B and C characters are not transmitted String format start data 1 check data 1 check stop char chars digit chars digit char Options for Codabar Enable ABC code concatenation Enable CD code concatenation Enable check digit check Disable transmission of the check digit Disable transmission of start stop Selection of start stop character translation ds Selection of minimum number of data characters Enable library space CLSI insertion Space insertion This option inserts spaces in position 2 7 and 13 of the data string for use in library systems ST SP translation This option enables the translation and transmission of t
19. SLOCK ON or if the host required upper case characters only Page 38 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Setting a Prefix or Suffix A Prefix and Suffix consisting of a maximum 4 direct input entries each may be included in front and at the end of the string respectively The following steps are used to establish a Prefix or Suffix that will be transmitted with the bar code data 1 Scan Start End Program Menu to enter programming mode 2 Scan the bar code representing the desired symbology you wish to add a Prefix or Suffix to 3 Scan the character s that comprise the Prefix or Suffix Up to 4 numbers letters or control characters may be used 4 Scan Start End Program Menu to exit programming mode Prefix Settings Start End zz osram III Menu ci IN so 4 Il UPC A moi cco 1111111111 UPC E Mi ccon DAN EAN 13 m2 caco 0 EAN 8 ms 225 Iu ma cot Il s Iu Ms II CONTINUED ON NEXT PAGE Page 39 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Prefix Settings continued ZZ Start End Program Menu M7 Interleaved 2015 M8 Code 93 M9 Code 128 NO MSI Plessey NI UPC A N2 UPC E N3 EAN 13 N4 EAN 8 RY All codes MG Clear all prefixes MZ Preamble
20. Transmit start stop as ABCD TN E F2 Transmit start stop as abcd tn e F3 Transmit start stop as ABCD ABCD F4 Transmit start stop as abcd abcd H3 Enable Codabar ABC and CX H4 Enable only ABC code 115 Enable only CX code H6 Check CD H7 Do not check CD H8 Transmit CD H9 Do not transmit CD Page 25 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner CONTINUED ON NEXT PAGE Page 26 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Codabar Settings continued Start End zz erosram INI Menu Enable Codabar HA is only Min data Min data Enable space Disable space Min data Enable nm III ee check Disable n sesta INI check Codabar Settings Codabar NW7 is a variable length symbology with an optional check digit and printable start stop characters Supported characters include Numeric digits 0 to 9 special characters Page 27 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld M start stop characters are A B C or D The checksum is calculated as the sum modulo 16 of the numerical values of all data characters String format start char data 1 or more chars check digit stop char CONTINUED ON NEXT PAGE Page 28 Manual
21. User s Manual OPT 6125 Series Handheld CCD Scanner 25 ULGPMUO1 01 April 2002 Keyboard Wedge Interface USB Interface RS232 Interface DI on 8 Olympic Drive Orangeburg NY 10962 Tel 845 365 0090 Fax 845 365 1251 www opticonUSA com Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Table of Contents PART I CCD Scanning General Information 4 Unpacking Factory Technical Support Part II Installation and SetUp A Installation Wedge Interface 5 Reset all Defaults 6 Computer Type Selection 6 InterCharacter Delay 7 B Installation RS232 Interface 8 RS 232C Communication Parameters 9 Bad Ratt etti ta ii 9 Data Bits Stop Bits Parity eee eee 10 C Installation USB Interface il NOTICE Opticon has taken every step to ensure that the information included in this manual is accurate however we reserve the right to change any specification at any time without prior notice Part III Bar Code Menu Functions Section A Programming the Scanner 12 Section B Svmbologv Selections 13 Enabling only a single symbology 13 Enabling an addition symbology 13 Setting Options
22. a pad 7J ESC 7K Arrow down 7L Arrow up 7M Arrow right TN Arrow left TT lt DEL gt VQ lt INSERT gt VR lt HOME gt VS lt END gt 70 Page up CONTINUED ON NEXT PAGE Page 44 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Keyboard Keys continued Start End Menu Left Left Left Right TV lt shift gt AMI Right Right Page 45 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Characters ZZ Start End Program Menu SA lt SPACE gt 5B SC SD 513 SF 5G 5H SI SJ SK SL SM SN CONTINUED ON NEXT PAGE Page 46 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Direct Input Characters continued LE Start End Program Menu SO SP 6A 6B 6C 6D 6E 6F 6G 7A 7B 7C 7D TE CONTINUED ON NEXT PAGE Page 47 Manual No 25 ULGPMU01 01 Series OPT Handheld CCD Scanner Direct Input Characters continued Start End zz gz Menu N PAN ori NNN u LLI U ovi IMI owi 11111111 CONTINUED ON NEXT PAGE Page 48 Manual No 25 ULGPMUO1 01 CCD Scanner
23. cluding what could constitute a check digit Do Not Transmit CD Disables the transmission of the check digit If the check digit calculation is disabled the reader cannot differentiate between a valid check digit and a data character It will therefore transmit all data characters of the able excluding the character that could constitute the check digit for the type of bar code Transmit ST SP Enables the transmission of the start and stop characters of a bar code Do Not Transmit ST SP Disables the transmission of the start and stop characters of a bar code Page 17 Manual No 25 ULGPMU01 01 CCD Scanner Series OPT Handheld UPC Settings Options for UPC A and UPC E bar codes NOTE Abbreviations Xmit transmit CD Check digit CC Country code ZZ Start End Program Menu E2 UPC A as EAN13 w CD 13 digits E3 UPC A w CD 12 digits E4 UPC A w CD 12 digits E5 UPC A w o CD 11 digits E6 UPC E w CC amp CD 8 digits E7 UPC E w o CC w CD 7 digits E8 UPC E w CC w o CD 7 digits E9 UPC E w o CC amp CD 6 digits 6P Xmit UPC E as UPC A w CD 8 digits 6Q Do not xmit UPC E as UPC A w o CD 7 digits Page 18 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner UPC Settings continued Options for UPC A The UPC A symbology is a fixed length symbology encodin
24. d buzzer will be activated after decoding the bar code but before transmission During transmission the buzzer sequence will be completed Buzzer After Transmission The good read buzzer will be activated after transmission Enable Startup Buzzer When this option is selected the reader will generate a single good read buzzer to indicate the reader is ready after the reader is supplied with power Disable Startup Buzzer When this option is selected the reader will not sound the buzzer after the reader is supplied with power Page 64 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Good Read LED Diagnostics ZZ Start End Program Menu T4 Disable indicator TS Indicator duration 0 2 sec T6 Indicator duration 0 4 sec T7 Indicator duration 0 8 sec ZZ Start End Program Menu ZI Transmit software version Z3 Transmit settings ZA Transmit ASCII printable string YV Transmit ASCII control string TH Error msg label TI Error msg no decode Page 65
25. eld Symbology Selection continued ZZ Start End Program Menu J2 UPC 2 oniv J3 UPC 5 oniv J4 EAN only J5 EAN 2 only J6 EAN 5 only J7 Industrial 20f5 only J8 Interleaved 20f5 only JD Trioptics only These options do not influence the reading of the menu labels The required bar code types can be selected by enabling a single readable code only and enabling a single readable code only and enabling readable codes It is strongly recommended that only the required codes be selected Page 14 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Svmbologv Additions If scanner will not be used to read all svmbologies default setting speed operation by using this menu to add only the specific symbologies being used add only the symbologies that are required Start End zz rogram INI Menu Bo 4 III 82 NINA ps amp A Ba MMI Bs 22 II 06 eS NM 87 so ser II 32 IW gi jie NI 2 ces HI III CONTINUED ON NEXT PAGE Page 15 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld Symbology Additions continued ZZ Start End Program Menu R4 Enable EAN R5 Enable EAN 2 R6 Enable EAN 5 R7 Enable Industrial 2015 R8 Enable Interleaved 20
26. ffer As soon as a Code 128 bar code is read without a leading FNC2 character the data is appended to the reader s buffer and the entire buffer is transmitted and cleared for new data In case a non Code 128 bar code is read the data in the non Code 128 bar code is transmitted and the buffer is cleared The buffer size is reader dependent Page 35 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner IATA Settings Start End Menu Do not e Se 1110 Check S N A only Inn Check CPN Check CPN S N at II wa IATA is a variable length symbology with an optional check digit and non printable start stop characters Supported characters include numeric digits 0 through 9 The checksum is calculated as the modulo seven of the data string IATA is acronym for International Air Transport Association String format A possible format of IATA is as follows 4M Do not transmit CD Code CPN AC FC SN CD Description Coupon Airline Code Form Code Serial Number Check Digit Digits 1 3 2 8 15 Options for IATA Enable check digit check Selection of the check digit calculation Disable transmission of the check digit Check digit If the check digit calculation is required then the appropriate calculation method must be selected Page 36 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld
27. for UPC A E 17 Setting Options for EAN 13 and 8 20 Code 39 Settings 22 Codabar Settings 24 2 01 5 SetUNdSs zen 27 MSI Plessev Setting 29 Code 128 Setting 30 TATA SONS a 5242229294222245 4225224592292245 9222945 2942 31 Section C Universal Selections Case Conversion 33 Prefix Options zu ieee bros lees bros oda hace ed ete eta Lie 34 Suffix Options a Hannah 36 Direct Input Keyboard KeyS 38 Direct Input Characters 44 Direct Input Control Characters 49 Read Mode Settings 52 Trigger 56 111 105 53 Beeper O0UOnS sss nanna 57 Good Read Indicator LED 59 Page 3 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Part I General Information The OPT 6125 Series CCD Scanners utilize state of the art imaging technology similar to that found in digital cameras facsimile machines and video camcorders The scanner images the bar code label then converts the digital signals into data the host computer can understand By capturing the bar code image all at once the scanner provides fast highly accurate reading Miniature surface mount electron
28. g 11 data digits a check digit and non printable start stop characters Supported characters are numeric digits 1 to 9 An optional leading zero can be transmitted which together with the data and the check digit forms a 13 digit field providing compatibility with the EAN 13 format String format Leading data check 0 11 digits digit UPC A add on 2 add on 5 The UPC A symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String format Leading data check add on 0 11 digits digit 2 or 5 Options for UPC A Disable transmission of the leading zero x Disable transmission of the check digit Options for UPC E The UPC E symbology is a fixed length symbology encoding 6 data digits a check digits and non printable start stop characters Supported characters include numeric digits 0 to 9 An optional leading zero can be transmitted which together with the data and the check digit forms an 8 digit field providing a compatibility with the EAN 8 format String format Leading data check 0 6 digits digit UPC E add on 2 add on 5 The UPC E symbology as described above can be succeeded by an additional 2 or 5 digit UPC A code String format Leading data check add on 0 6 digits digit 2 or 5 Options for UPC E Enable transmission of the leading zero Disable transmission of the check digit Transmit UPC E as UPC
29. git UPC A code String format data check add on 7 digits digit 2 or 5 Options for EAN iS Disable transmission of the check digit f Enable ISBN or ISSN translation Enable ISBN or ISSN translation If this option is enabled an EAN 13 label is verified for the correct format and transmitted as a 10 digit ISBN number or 8 digit ISSN number Page 21 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Code 39 Settings Start End zz eoram IND Menu co cs eo I ci II po II Di ise IRI 94 AAN os 2 MAN os e TMN 9 5 JJMIMMMINI Full ASCII possible Enable Disable Page 22 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Minimum sp Si AN Minimum se AN CONTINUED ON NEXT PAGE Page 23 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Code 39 Settings continued Code 39 is a variable length symbology with an optional check digit CD and printable start stop ST SP characters The following characters are supported e Numeric characters 0 to 9 e Alpha characters capital A to Z e Special characters and SPACE e Start stop character is The checksum is calculated as the sum modulo 43 of the numerical value of the data characters In full ASCII mode all 128 ASCII characters are supported This is done by combining one of
30. he start and stop characters Thus if the option ST SP abcd tn e is chosen the start character is converted to lower case e g from A B Cor D to a b cor d respectively and the stop character is converted from A B C or D to t n or e respectively Minimum data characters Codabar labels are checked for a minimum of 1 3 or 5 characters as set by the user If the number of characters in the label is shorter than the minimum selected the label will be rejected If the fixed length option is used for Codabar type labels then such labels will additionally be checked for fixed length This option will no longer be supported in future software releases Intercharacter gap check This option enables the reading of Codabar labels with a large or irregular gap between characters Page 29 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handheld 20f5 Settings Start End Menu Transmit EU CD I l Ill Ill Do not Do not Min data Min data Min data Enable space Industrial 2015 Disable space Industrial 2015 ME ME ME CONTINUED ON NEXT PAGE Page 30 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner 2015 Settings continued Code 2015 is a variable length symbology with an optional check digit and non printable start and stop character Supported characters include numeric digits 0 to 9 The checksum is calculated as the sum modulo 10 of the
31. ics make up the CCD scanner s solid state construction CCD scanners have no moving mechanical parts and provide years of trouble free operation This manual contains information on setting up the scanner as well as programming various parameters of the scanner The OPT6125 scanner is available in several different interface configurations Keyboard Wedge Interface RS232 Serial Interface USB Interface There is a specific section of this manual for installing each type of interface Be sure you are using the section of the manual that pertains to interface you are using Unpacking Remove the scanner from its packaging and inspect it for damage If the scanner was damaged in transit call the dealer or distributor from whom you purchased it If you purchased it directly from Opticon call Opticon Customer Service Dept at 800 636 0090 Factory Technical Support If you have any questions or need assistance with programming your scanner call Opticon Technical Support at 800 636 0090 please have the unit model number and several bar code labels readily at hand The model number is located near the connector end of the cable If the scanner must be returned please contact Opticon to obtain an RMA Return Merchandise Authorization number prior to returning the product The Customer Service Dept may be reached at 800 636 0090 NOTE Returned merchandise will not be accepted without a RMA number indicated clearly on the outside of the carton
32. l I u2 nm ILU U End ZA LI Page 8 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner RS 232C Communication Parameters Handshaking Protocol Baud Rate ZZ Start Program Menu PO None HP04 RTS CTS P3 ACK NAK ZG Xon Xoff 10 Flow Control Time Unlimited Il Flow Control 100ms 12 Flow Control 200ms 13 Flow Control 400ms K7 19200 K6 9600 K5 4800 K4 2400 1200 600 Page 9 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Data Bits Stop Bits Parity Lo n ne 111111111 Li nap IH o 15 jiso IH o 16 252 IUI Even Eu LIMI Odd 1 LL ULI Mark L2 No Parity linn D End ZZ Program ZZ Menu R i Page 10 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner C Installation USB Interface Plug the scanner into the USB connector on your host computer PC must be running Windows 98 or higher or iMac Rev A or higher The computer will sense the presence of the scanner and load any required software drivers automatically Reset All Defaults USB Interface Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers In most applications the scanner will work right out of the box without any need for additional programming At an
33. scanner will beep once and the green light will flash indicating the desired parameter has been scanned The scanner will continue to beep continuously while in Programming Mode 3 Scan Start End Program Menu ZZ The scanner will stop beeping indicating that it is back in normal scanning mode The changes made while in Programming Mode are now saved in the scanner s memory When the scanner is in Programming Mode more than one parameter at a time can be changed Until some proficiency at programming is achieved it is highly recommended that users only change only one parameter at a time and test the change before proceeding to program any additional changes It is also recommended that users keep a record of the changes made to the scanner What If I Make A Mistake Scanning the Reset All Defaults bar code for your type of interface will return the scanner to all factory default settings including any changes made during previous programming sessions NOTE R A pointing finger indicates scanner default settings throughout the following menus Page 12 sua No 25 ULGPMU01 01 Series OPT Handheld Canner Symbology Selection Start End zz osram INI Menu ao sists IUI p 00 as II aa osons ANNAT as amp 1 as S NNN 3 MINIMI Kate 00 a I A ONINI A ILI CONTINUED ON NEXT PAGE Page 13 Manual No 25 ULGPMUO1 01 CCD Scanner Series OPT Handh
34. y time you can return the scanner to the factory default settings by scanning the Reset all Defaults programming bar code below Start zz wooren AAA Menu su uss End ZZ logs e INI Page 11 Manual No 25 ULGPMUO1 01 Series OPT Handheld CCD Scanner Part III Bar Code Menu Functions Section A Programming the Scanner This manual contains information that allows you to easily change certain programmable parameters of the scanner The scanner is ready to use no additional programming is required in most situations The scanner has been programmed at the factory with the most common settings These factory default settings are ideal for most situations A specific parameter is set or changed by scanning one or more of the special programming bar codes found on the following pages For each parameter you can choose from a menu of options When you scan the special bar code for a specific menu option the scanner retains the changes you have made even if you disconnect the scanner or t urn off the power Step by Step Programming is easy Simply 1 Scan the bar code for Start End Program Menu ZZ The scanner will beep continuously to indicate that it is ready to be programmed When the scanner is in Programming Mode it cannot read normal bar code It can only read the special bar codes found on the following pages 2 Select desired parameter from menu and scan the bar code The