Home
On-Q/Legrand REV.O 1307877 User's Manual
Contents
1. 800 321 2343 O legrand u Page 33
2. Enable DHCP Use the following IP Setting Ip Address Default Gateway Apply Restore Figure 24 2 The Enable DHCP button is selected when you want the server to automatically assign the IP Address Subnet Mask and Default Gateway of the WAP If you are going to make the WAP part of the Router s subnetwork you would instead click on the Use the following IP Setting button 3 Ifthe router is using the 192 168 10 subnetwork enter 192 168 10 100 into the IP Address field Use an address like 100 that is higher than the number of PCs you are likely to attach to this router 4 Enter 255 255 255 0 into the Subnet Mask field 5 Enter 192 168 10 254 into the Default Gateway field and click Apply 6 To verify that you can access the WAP 802 11g at its new IP address run the Ping command ping 192 168 10 100 from any router attached PC Middletown PA 17057 www onglegrand com 800 321 2343 O legrand en Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Page 15 E Allowing Client Access with MAC Addresses 1 Another form of security and the one that we recommend is to specify in a list which wireless clients can gain access to your On Q WAP 802 11g device Every potential wireless client PC for example contains an address that uniquely identifies it This address is called the Media Access Control or MAC address Click on the words Access Cont
3. Wireless 4 Status Indicators Detailed Description Data Indicator ON Blue The device is connected to a data network OFF The device is powered off or not connected to a data network Wireless Indicator ON Blue The device is on and operating normally OFF The device is powered off Blinking Blue The device is transmitting or receiving data Power Indicator ON Blue The device is powered on and operating normally OFF The device is powered off or performing a boot sequence Blinking Blue Firmware upgrade failed 5 WAP 802 11g Reset Button Access Figure 4 shows the WAP 802 11g with the cover removed to gain access to the Reset Button As shown there is a tab that when pushed in the direction shown will activate the Reset Button Pushing and holding this tab for five seconds or more will return the unit to Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand Page 3 factory default condition This is particularly handy if someone configured a security level or IP Address by mistake that prohibits you from gaining access to the unit Figure 4 6 WAP 802 11g Power Over Cat 5e Inserter Module Figure 5 shows the WAP Inserter Module components 24VDC in from Power Supply Data in from ISP Figure 5 OI Q 301 Fulling Mil
4. Firmware is typically upgradeable FTP File Transfer Protocol is a standard Internet protocol for exchanging files between computers FTP is commonly used to download programs and other files to a computer from web pages on Internet servers G Gateway A device that enables communication between networks using different protocols See also router GUI Graphical User Interface Ol if Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand wm Page 27 H Hexadecimal A base sixteen numbering system that uses sixteen sequential numbers 0 to 9 and the letters A to F as base units before adding a new position On computers hexadecimal is a convenient way to express binary numbers Host In IP a host is any computer supporting end user applications or services with full two way network access Each host has a unique host number that combined with the network number forms its IP address Host also can mean A computer running a web server that serves pages for one or more web sites belonging to organization s or individuals A company that provides this service or In IBM environments a mainframe computer ICMP Internet Control Message Protocol is a protocol used for error problem and informational messages sent between IP hosts and gateways ICMP messages are processed by the IP software and are not usually apparent to the
5. 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand i Page 23 If you do NOT receive a reply try from a different computer to verify that the first PC is not the cause of the problem In the Command window type ping and your ISP s default gateway and press Enter For example type ping 192 168 1 1 If you receive a reply It might look something like this Reply from 216 109 125 72 then your connection to the Internet is alive and well You can verify the ISP s IP address at the Gateway IP field on the Control Panel gt Network Access screen If you do NOT receive a reply try from a different computer to verify that the first PC is not the cause of the problem If you cannot determine your ISP s default gateway ping www yahoo com or another known web location 2 I cannot configure the WAP 802 11g over the network a b Cc on Q O legrand Verify your Ethernet connection to the WAP Verify that the IP address of the PC being used to configure the WAP is on the same network as the WAP s configuration IP address The IP address of your network adapter must be on the same network and not a duplicate of any others on the network for example 192 168 1 3 and using a subnet mask of 255 255 255 0 can be used to login to the WAP s default IP address of 192 168 1 1 Refer to Section Ill Configuration gt Configu
6. 5e Jumper Cable This WAP Owner s Manual on CD WAP IS Sheet and User Guide Replacement Parts Replacement parts available for the On Q WAP 802 11g include e WAP 24 VDC Power Supply with AC cord P N 364889 01 e WAP Power Over Cat 5 Inserter Module P N 364888 01 On Q WAP 802 11g Detailed Physical Description The following information describes the physical characteristics of the WAP Assembly 1 WAP Assembly Connections P N 364887 01 shown Figure 2 shows the WAP Assembly connection area including Cat 5e from Power Inserter in enclosure INPUT connection Figure 2 Ol s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand i Page 2 2 Connection Area Detailed Description INPUT This RJ 45 connector is where the Cat 5e cable from the Power Over Cat 5e Inserter Module in the On Q Enclosure plugs in There is an Extractor Module in the WAP Assembly that breaks out the required DC power from the data on the input Cat 5e cable connection NOTE Notice in Figure 2 that there is also a small factory installed jumper cable that supplies the required DC power and data to the WAP assembly 3 WAP Assembly Status Indications P N 364891 01 shown Figure 3 shows the WAP 802 11g Assembly status indicators which are visible when the WAP cover is properly installed Figure 3
7. Access Control address is a unique 48 bit value permanently saved in the ROM at the factory to identify each Ethernet network device It is expressed as a sequence of 12 hexadecimal digits printed on the unit s label You need to provide the MAC Address to the cable service provider Also called an Ethernet address physical address hardware address or NIC address MB One megabyte equals 1 024 x 1 024 bytes 1 024 kilobytes or about 8 million bits Mbps Million bits per second megabits per second A rate of data transfer MTU The Maximum Transmission Unit is the largest amount of data that can be transmitted in one discrete message on a given physical network The MTU places an upper bound on the size of a message that can be transferred by the network in a single frame Messages exceeding the MTU must be fragmented before transmission and reassembled at the destination Multicast A data transmission sent from one sender to multiple receivers See also broadcast and unicast N NAT Network Address Translation is an Internet standard for a LAN to use one set of IP addresses for internal traffic and a second set of IP addresses for external traffic NAT provides some security because the IP addresses of LAN computers are invisible on the Internet Network Two or more computers connected to communicate with each other Networks have traditionally been connected using some kind of wiring NIC A Network Interface Card converts c
8. You can click on this to see the status of your Ethernet adaptor Also in Control Panel gt Network and Dial Up Connections you can examine the state of your Ethernet adaptor C Software Situations 1 I would like to see if my Internet connection is alive a For this you will use the ping command to test the connection Before attempting ensure that Obtain an IP address automatically has been selected in the computer s settings and that you have an IP address assigned Refer to Section IV Configuration for further details b Open a command prompt by clicking Start and Run For Windows 98 and ME in the Open field type command and press Enter or OK For Windows 2000 and XP type cmd or navigate using your Start button to Programs gt Accessories gt Command Prompt c Inthe Command window type ipconfig You should see an IP address for your network adapter similar to the following example IP Address 192 168 1 3 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 d Inthe Command window type ping followed by the WAP s IP address and press Enter For example type ping 192 168 1 3 There is a good possibility that the Default Gateway s IP address is the WAP s IP address You can verify the WAP s IP address on the Control Panel gt Network Access screen If you receive a reply the first word will be Reply then your computer is connected to the WAP Proceed to Step e Ol J Q
9. legrand i Page 19 VI Troubleshooting This section will detail possible solutions to common problems that might occur in using the On Q Wireless Access Point WAP 802 1 1g A Contact Information If you are unable to locate a solution here please access our website at www onglegrand com for the latest information You can also reach us at 1 800 321 2343 B Hardware Situations 1 WAP 802 119 Cover Removal Some of the steps in this section may require removal of the WAP 802 11g cover or the WAP Assembly unit to verify cabling Use a small pointed object like a paper clip to remove the WAP cover by gently prying in the slot at the location indicated see Figure 30 N Figure 30 2 WAP 802 119 Assembly Removal The WAP 802 11g Assembly itself is removed by unscrewing the six screws that hold it to the 3 gang box it is mounted in see Figure 31 Figure 31 Ol s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com Oo legrand 800 321 2343 Page 20 3 Restoring Factory Defaults If you need to reset the WAP 802 1 1g to factory default settings there are two methods that can be used You can login to the device and click on the Restore button at the bottom of each screen or once the cover has been removed you can simply push and hold the Reset tab in the direction shown for at least 5 seconds see Figure 32 This action will restore
10. what the router will examine for the destination of an IP address A router delivers packets using the network address Switch On an Ethernet network a switch filters frames based on the MAC address in a manner similar to a bridge A switch is more advanced because it can connect more than two segments Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand wm Page 31 T TCP Transmission Control Protocol on OSI transport layer four provides reliable transport over the network for data transmitted using IP network layer three It is an end to end protocol defining rules and procedures for data exchange between hosts on top of connectionless IP TCP uses a timer to track outstanding packets checks error in incoming packets and retransmits packets if requested TCP IP The Transmission Control Protocol Internet Protocol suite provides standards and rules for data communication between networks on the Internet It is the worldwide Internetworking standard and the basic communications protocol of the Internet Tunnel To place packets inside other packets to send over a network The protocol of the enclosing packet is understood by each endpoint or tunnel interface where the packet enters and exits the network VPNs rely on tunneling to create a secure network Tunneling requires the following protocol types A carrier prot
11. which the WAP is communicating Review your adapter s documentation for further instructions d Ensure that your wireless adapter for your PC and the WAP 802 11g have the same security settings that will allow your computer to access the wireless network e Ensure that your WAP is within range of your router or is not behind an obstruction for example metal structures will interfere with the signal as will 2 4 GHz cordless phones and microwaves 6 My computer is experiencing difficulty in connecting to the WAP 802 11g a Check that all of your cable connections are tight and secured This includes the cables to your modem the router the WAP 802 11g and to your PC b Ensure that your LEDs are lit For further information about LED descriptions see Section Il Product Overview c Ensure that you are using Ethernet cables and not telephone cables see Figure 35 Ethernet cables use a wider RJ 45 style plug using 8 wires where telephone style plugs use the smaller RJ 11 4 pin or RJ 25 6 pin style plugs Ol J Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand i Page 22 Figure 35 NOTE The plug on the left is RJ 45 the plug on the right is RJ 11 Use only RJ 45 d Ensure that your Ethernet adapter is enabled Check the System Tray at the bottom right of your display to see an icon that looks like a monitor
12. 005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand en Page 30 ROM Read Only Memory Router On IP networks a device connecting at least two networks which may or may not be similar A router is typically located at a gateway between networks A router operates on OSI network layer 3 It filters packets based on the IP address examining the source and destination IP addresses to determine the best route on which to forward them A router is often included as part of a network switch A router can also be implemented as software on a computer Routing Table A table listing available routes that is used by a router to determine the best route for a packet RTS Request To Send S Server In a client server architecture a dedicated computer that supplies files or services such as file transfer remote login or printing to clients Also see client Service Provider A company providing Internet connection services to subscribers SMTP Simple Mail Transfer Protocol is a standard Internet protocol for transferring e mail Static IP Address An IP address that is permanently assigned to a host Normally a static IP address must be assigned manually The opposite of Dynamic IP Address Station IEEE 802 11b term for wireless client Subscriber A user who accesses television data or other services from a service provider Subnet Mask A methodology that determines
13. EE This standard is subdivided into distinct categories of speed and the frequency spectrum used designated by the lower case letter after the standard Your On Q WAP 802 11g supports both the 802 11b and 802 1 1g specifications Figure 1 P N 364887 01 P N 364891 01 The 802 11b specification transmits data rates up to 11 Mbps while the 802 11g specification transmits data rates up to 54 Mbps These are theoretical speeds so your performance may vary The radio waves radiate out in a donut shaped pattern The waves travel through walls and floors but transmission power and distance are affected The following chart shows how the wireless range is different for each data rate and also depends on the local conditions Data Rate Open Area Closed Area 54 Mbps Up to 100 ft Up to 60 ft 11 Mbps Up to 900 ft Up to 160 ft 5 5 Mbps Up to 1300 ft Up to 200 ft 2 or 1 Mbps Up to 1500 ft Up to 300 ft Typically the best performance can be expected by positioning it in the ceiling or wall at a central location on the top floor of the home or where a localized hot spot is desired The following recommendations help you achieve the best wireless performance environment e Placing the WAP in the physical center of your network is the premium location because the antenna radiates out the signal in all directions e Placing the WAP in a higher location helps to disperse the signal cleanly especially to receiving locations on upper storie
14. Inserter 8 Next verify that the Power LED is lit on the WAP 9 If you connected to an active network verify that the Network Activity LED is lit on the network access device and on the WAP 10 Then verify the Wireless LED is lit on the WAP Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com oO legrand 800 321 2343 Page 7 IV Configuration Steps The On Q WAP 802 11g is typically configured in one of two ways 1 From a portable PC connected through the Data In port of the Power Inserter Module in the enclosure which is then connected through its Data Power Out port to a Cat 5e cable to the WAP or 2 From a PC in one of the rooms of the house connected through an outlet in the room to the enclosure where it is patched to the Data In port of the Power Inserter Module in the enclosure which is then connected through its Data Power Out port to a Cat 5e cable to the WAP see Figure 11 In either case the PC must have an Ethernet Network Interface Card to communicate with the WAP Figure 11 Single Cat 5e To WAP NS PC with Ethernet Card WAP 802 11g PC with Ethernet Card NOTE The On Q WAP 802 11g can also be configured from a PC containing a Wireless Network Interface Card for your desktop PC or wireless PCMCIA card for your laptop PC but this is not recommended because it is not secure u
15. Rights Reserved Middletown PA 17057 www onqlegrand com Eu 800 321 2343 O legrand en Page 8 A Configuring a Windows XP Ethernet Network Interface Card to talk to the WAP This section includes information on configuring computers with the Windows XP operating system differences for 98SE ME and 2000 will be sited NOTE This configuration assumes you have retained the default interface for Windows XP If you are running the Classic interface please note any sited differences for Windows 2000 1 Click Start 2 Select Control Panel For Windows 98SE ME and 2000 select Settings first 3 Double click Network and Dial Up Connections Double Click Network for Windows 98SE and ME and the Network Window is displayed 4 Double click Local Area Connection The Local Area Connection Status window appears see Figure 12 Step 5 is not applicable for Windows 98SE or ME J Local Area Connection Status General Support Connection Status Connected Duration 00 00 11 Speed 100 0 Mbps Activity Received Bytes 1 180 Properties Figure 12 Ol u Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com oO legrand 800 321 2343 Page 9 5 Click the Properties button to go to the Local Area Connection Properties screen Step 6 is not applicable for Windows 98SE or ME 4 Local Area Connection Properties General Ad
16. ay void the user s authority to operate the equipment The manufacturer is not responsible for any radio or television interference caused by unauthorized modification of this device or the substitution or attachment of connecting cables and equipment other than manufacturer specified It is the responsibility of the user to correct any interference caused by such unauthorized modification substitution or attachment Manufacturer and its authorized resellers or distributors will assume no liability for any damage or violation of government regulations arising from failing to comply with these guidelines This device and its antenna s must not be co located or operating in conjunction with any other antenna or transmitter Declaration of Conformity R amp TTE directive 1999 5 EC The following items were completed and are considered relevant and sufficient Essential requirements as in Article 3 Protection requirements for health and safety as in Article 3 1a Testing for electric safety according to EN 60950 Protection requirements for electromagnetic compatibility in Article 3 1b Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com Eu 800 321 2343 O legrand Em Page ii Testing for electromagnetic compatibility in EN 301 489 1 amp EN 301 Testing according to 489 17 Effective use of the radio spect
17. bit WEP 128 bit WEP or TKIP depending on which Authentication Method was chosen If Shared Key was chosen 64 bit and 128 bit WEP encryption keys may be manually assigned by entering digits in the four WEP Key fields or automatically generated by entering 8 to 64 letters numbers or symbols in the Passphrase field In this case the four WEP Keys will be generated when you click on the Apply button NOTE You must specify which of the generated WEP Keys you want to be the default WEP Encryption Key in the Default Key field 17 If WPA PSK was chosen as the Authentication Method you must enter a Passphrase in that field and set the WPA Re key Timer value 1 2 147 483 647 seconds This will determine the time interval before the WPA group key is changed A shorter time interval will make for a more secure wireless network Ol J Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand ie Page 14 D Configuring the WAP 802 11g to work with a Router If you are connected to the Internet through a Router you will want to change the IP Address of the WAP to also be a member of the Router s subnetwork This will allow you to access the WAP at a future date if you need to re configure its security or login settings 1 Use the Ethernet Interface area at the bottom of the Simple Setup Screen to accomplish these tasks see Figure 24
18. d PC on the Router network they can also be used to configure the WAP Network Interface Card for DHCP control by selecting the WAP NIC at the top of this screen 7 Click to highlight Internet Protocol TCP IP and click the Properties button to go to the Internet Protocol TCP IP Properties screen For Windows 98SE or ME from the Network Window s configuration tab select the TCP IP line the for the appropriate Ethernet adapter and Click Properties From the TCP IP Properties Window Click on the IP Address tab Internet Protocol TCP IP Properties General Alternate Configuration You can get P settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Dbtain an IP address automaticaly Use the following IP address Obtain DNS server address automatically O Use the following DNS server addresses 0K Cancel Figure 28 8 Select Obtain an IP address automatically see Figure 28 9 Click OK twice to exit and save your settings For Windows 98SE ME or 2000 you will have to restart the computer to save these settings 10 After the reboot if appropriate your PC should be now be ready for operation as before directly through the Router or through the WAP if a Wireless NIC card was installed Ol u Q 301 Fulling Mill Road Suite G Copyright 2005 by O
19. d wm Page 25 Cc Client In a client server architecture a client is a computer that requests files or services such as file transfer remote login or printing from the server On an IEEE 802 11b g wireless LAN a client is any host that can communicate with the wireless access point Also called a CPE A wireless client is also called a Station Also see server Coaxial Cable A type of cable consisting of a center wire surrounded by insulation and a grounded shield of braided wire The shield minimizes electrical and radio frequency interference Coaxial cable has high bandwidth and can support transmission over long distances CPE Customer Premise Equipment typically computers printers etc that are connected to the gateway at the subscriber location CPE can be provided by the subscriber or the cable service provider Also called a client Crossover Cable A crossover cable is a cable that is used to interconnect two computers by crossing over reversing their respective pin contacts A crossover cable is sometimes known as a null modem D Default Gateway A routing device that forwards traffic not destined to a station within the local subnet DHCP A Dynamic Host Configuration Protocol server dynamically assigns IP addresses to client hosts on an IP network DHCP eliminates the need to manually assign static IP addresses by leasing an IP address and subnet mask to each client It enables the automatic reuse of unu
20. eiver is connected Consult the dealer or an experienced radio TV technician for help Reprinted from the Code of Federal Regulations 47 part 15 193 1993 Washington DC Office of the Federal Register National Archives and Records Administration U S Government Printing Office Canadian Department of Communications This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada FCC Radio Frequency Exposure Caution Statement In order to maintain compliance with the FCC RF exposure guidelines this equipment should be installed and operated with minimum distance 20cm between the radiator and your body Use only with supplied antenna Unauthorized antenna modification or attachments could damage the transmitter and may violate FCC regulations Any changes of modifications not expressly approved by the grantee of this device could void the users authority to operate the equipment Installation and use of this Wireless LAN device must be in strict accordance with the instructions included in the user documentation provided with the product Any changes or modifications including the antennas made to this device that are not expressly approved by the manufacturer m
21. end user IEEE The Institute of Electrical and Electronics Engineers Inc http www ieee org is an organization that produces standards technical papers and symposiums for the electrical and electronic industries and is accredited by ANSI 802 11b and 802 119 are examples of standards they have produced Internet A worldwide collection of interconnected networks using TCP IP IP Internet Protocol is a set of standards that enable different types of computers to communicate with one another and exchange data through the Internet IP provides the appearance of a single seamless communication system and makes the Internet a virtual network IP Address A unique 32 bit value that identifies each host on a TCP IP network TCP IP networks route messages based on the destination IP address For a Class C network the first 24 bits are the network address and the final 8 bits are the host address in dotted decimal format it appears network network network host ISDN Integrated Services Digital Network ISP Internet Service Provider L LAN Local Area Network A local area network provides a full time high bandwidth connection over a limited area such as a home building or campus Ethernet is the most widely used LAN standard Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand wm Page 28 MAC Address The Media
22. ernet to provide a secure and fast connection usually to users working remotely at home or in small branch offices A VPN connection provides security and performance similar to a dedicated link for example a leased line but at much lower cost Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand wm Page 32 Ww WAN A wide area network provides a connection over a large geographic area such as a country or the whole world The bandwidth depends on need and cost but is usually much lower than for a LAN WAP Wireless Access Point or Wireless Access Protocol See also Access Point WEP Wired Equivalent Privacy encryption protects the privacy of data transmitted over a wireless LAN WEP uses keys to encrypt and decrypt transmitted data The access point must authenticate a client before it can transfer data to another client WEP is part of IEEE 802 11b Wi Fi Wireless fidelity pronounced why fy brand name applied to products supporting IEEE 802 11b g WLAN Wireless LAN WPA Wi Fi Protected Access A security regimen developed by IEEE for protection of data on a WLAN WWW World Wide Web An interface to the Internet that you use to navigate and hyperlink to information Ol 2 Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com
23. evice to broadcast its SSID in a wireless network which allows other wireless devices to scan and establish communication with the device Unchecking this option what we recommend hides the SSID to prevent other wireless devices from recognizing and connecting to the device Ol J Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com m 800 321 2343 O legrand i Page 12 10 Click on the Associated Stations link beside the SSID to display a list of wireless devices associated with this WAP The list includes the wireless device MAC address and connection status see Figure 18 Simple Setup Access Control Firmware Upgrade MAC Address No associated station found Figure 18 11 The Channel field allows you to select which channel this device will use to communicate with other wireless devices in the network Click on the down arrow at the right of the field to see the selections as shown in Figure 19 The default channel is Channel 1 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 Channel 10 Channel 11 Figure 19 NOTE The IEEE 802 11g standard supports up to 13 channels worldwide Each channel is assigned a center frequency 5 MHz higher or lower than the adjacent channel A 30 MHz separation may be required to avoid interference between two wireless networks operating in close proxim
24. following DNS server addresses Preferred DNS server 5 i Altemate DNS server k Advanced Figure 14 OI s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com oO legrand 800 321 2343 Page 10 8 Click on Use the following IP Address so that the circle is filled see Figure 14 9 Enter 192 168 1 10 into the IP Address field 10 Enter 255 255 255 0 into the Subnet Mask field 11 Click OK twice to exit and save your settings For Windows 98SE ME or 2000 you will have to restart the computer to save these settings 12 After the reboot if appropriate proceed to the next section to set up the WAP security settings B Logging on to the WAP 1 Once the PC s Ethernet Interface Card is configured on the WAP s subnetwork open your web browser and Enter into the URL field http 192 168 1 1 the WAP s default IP address and press Enter see Figure 15 Beal Gerda Figure 15 The login screen will appear see Figure 16 Enter Network Password 2 x gt Please type your user name and password Site 192 168 1 1 Realm WL330q User Name Password I Save this password in your password list Cancel Figure 16 2 Enter the User ID The default factory setting is admin without the quotation marks 3 Enterthe Password The default factory setting is admin with
25. ion See NAT Ad Hoc Network A temporary local area network connecting WAP clients together usually just for the duration of the communication session The clients communicate directly to each other and not through an established link such as through a router Also known as IBSS Independent Basic Service Set ANSI The American National Standards Institute is a private organization that coordinates the setting and approval of some U S standards It also represents the United States to the International Standards Organization ASCII The American Standard Code for Information Interchange refers to alphanumeric data for processing and communication compatibility among various devices normally used for asynchronous transmission Bandwidth The transmission capacity of a medium in terms of a range of frequencies Greater bandwidth indicates the ability to transmit more data over a given period of time bps Bits Per Second Broadband A communications medium that can transmit a relatively large amount of data in a given time period Broadcast Data transmission to all addresses or functions BSS Basic Service Set A configuration of Wireless Access Points that communicate with each other without resorting any infrastructure Also known as Ad Hoc networks Also see ESS Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legran
26. ity Each associated wireless client must use the same channel number in order to communicate 12 The WAP 802 11g can have its Operation Mode set to operate in either an 802 11b client only mode an 802 11g client only mode or a mixed mode as shown in Figure 20 Figure 20 13 The Transmit Rate allows you to select the data transmission rate from 1 Mbps to 54 Mbps for devices as shown in Figure 21 The default is Auto Figure 21 OI Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand i Page 13 14 The Preamble see Figure 22 allows you to adjust the preamble mode for a 2 4GHz 11Mb network to Long Short or Auto The default preamble mode is Long Automatic Short Figure 22 Long 15 There are three different security Authentication Methods that may be selected as shown in Figure 23 Open System or Shared Key the default selection allows the device to accept connection requests from any wireless device in its operating range while Shared Key allows only devices with the same 64 bit WEP Wired Equivalent Privacy or 128 bit WEP encryption key access to the device and WPA PSK Wi Fi Protected Access Pre Shared Key allows only devices with the same TKIP Temporal Key Integrity Protocol encryption key access to the device Shared K Figure 23 WPA PSK 16 The Encryption field can be None 64
27. l Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com oO legrand 800 321 2343 Page 4 lll Installation The On Q WAP 802 11g is best installed during new construction in two steps at rough in with the other low voltage cabling such as TV and Phone but prior to drywall being installed and at trim out after the drywall is installed and painted These steps are detailed below A Rough in steps 1 A single Cat 5e should be run in the walls from a plastic triple gang box not supplied at the location in the home where the On Q Wireless Access Point WAP will be installed to the location where the Power Inserter Module will be located On Q enclosure leaving extra cable at both ends NOTE The preferred location for the WAP 802 114 is in the ceiling or wall of the top floor centrally located in the home see Figure 6 If multiple WAPs are used they should be located in overlapping wireless zones Figure 6 Single Cat 5e WAP 802 11g Ol s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com i 800 321 2343 O legrand Em Page 5 B Trim out steps 1 The Cat 5e cable that was run from the triple gang plastic box to the enclosure should be pulled out of the box and terminated with an RJ 45 plug as shown in Figure 7 NOTE Use proper tools and sta
28. ming communication with specified applications PPP Point to Point Protocol is used to transport other protocols typically for simple links over serial lines It is most commonly used to access the Internet with a dial up modem PPPoE Point to Point Protocol over Ethernet Used by many DSL Internet Service Providers for broadband connection PPTP Point to Point Tunneling Protocol encapsulates other protocols It is a new technology to create VPNs developed jointly by several vendors Private IP Address An IP address assigned to a computer on a LAN by the DHCP server for a specified lease time Private IP addresses are invisible to devices on the Internet See also Public IP Address Protocol A formal set of rules and conventions for exchanging data Different computer types for example PC UNIX or mainframe can communicate if they support common protocols Public IP Address The IP address assigned to the router or WAP by the service provider A public IP address is visible to devices on the Internet See also Private IP Address R RJ 11 The most common type of connector for household or office phones RJ 45 An 8 pin modular connector the most common connector type for 10Base T or 100Base T Ethernet networks Roaming In wireless networking roaming refers to the ability t0 move from one AP coverage area to another without interruption in service or loss in connectivity Ol i Q 301 Fulling Mill Road Suite G Copyright 2
29. n Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com o legrand 800 321 2343 Page 18 G Firmware Upgrades 1 Click on Firmware Upgrade at the top right of the Setup Screen see Figure 29 Simple Setup Access Control Firmware Upgrade Firmware Version azss37 sd Regulation Domain 0x10 FCC u s New Firmware File New Password Retype New Password Apply Restore goahead WEBSERVER Figure 29 2 This screen shows you the Product ID current Firmware Version and Regulation Domain 3 Access the On Q Legrand website at www onglegrand com to download the latest firmware from Technical Support a Download the latest file to your computer b To locate the file you downloaded type the path to the file or click Browse and navigate to it c Click Upgrade to update the WAP 802 11g with the selected firmware file The WAP will inform you that it is upgrading and the browser will refresh when it is complete H Login Password Change 1 To change your login password simply type in a new password in the New Password field and re type it in the Retype New Password field 2 Click on Apply to make the new password active 3 As on other screens click on the Restore button only if you want to return to factory defaults Ol J Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O
30. ndard TIA 568A rules to prep and terminate the Cat 5e cable such as the On Q Cat 5 Cable Stripper P N 363292 01 and the On Q EZ RJ45 Crimp Tool P N 364555 01 Figure 7 Figure 8 2 It should then be plugged into the INPUT connector on the rear of the WAP Assembly as shown in Figure 8 3 The On Q WAP 802 11g Assembly can then be screwed into the triple gang box and the cover inserted insuring that the LEDs on the WAP line up with the holes in the cover see Figure 9 Figure 9 OI J Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand i Page 6 4 Inthe structured wiring enclosure see Figure 10 the Cat 5e from the WAP 802 11g can be terminated with an RJ45 plug which is then connected directly to the output of the Power over Cat 5e Inserter Module P N 36488 01 Data Power out to WAP Power Over Cat 5e Cat5e Inserter patch cable Module 5 A supplied Cat 5e patch cable is then connected from the input RJ 45 jack of the Power over Cat 5e Inserter Module to one of the LAN ports on the On Q or third party Router or directly to a Broadband Modem 6 The Power over Cat 5e Inserter Module is powered with a 24 Volt DC power supply which needs to be plugged in to an AC source 7 When the 24 VDC Power Supply is plugged in to an active AC Source verify that the Power LED is lit on the Power
31. ntil you have configured security levels on the WAP NOTE Before configuring the On Q WAP 802 11g you must first temporarily configure your computer with installed Ethernet Network Interface Card to talk to the WAP The WAP comes configured to a specific IP subnetwork 192 168 1 xxx and its default IP address in that subnetwork is 192 168 1 1 so your PC s Ethernet Card must be assigned an IP address like 192 168 1 10 on that same subnetwork to talk to and configure the WAP Giving the PC a specific IP address is also called assigning it a Static IP address as compared to a Dynamic IP address that is typically assigned by a service provider through a process called Dynamic Host Configuration Protocol DHCP NOTE Before doing any PC IP Address re configuration make sure you first write down all of the current IP settings If your PC is running XP you may want to first create a manual system restore point under Accessories System Tools System Restore NOTE After initially configuring the WAP using that Static IP Address that you assign you may need to return the PC s IP Address setting to be dynamically assigned by DHCP if that is what the service provider requires If you are using a router you will also want to change your WAP s IP address and Gateway settings to be compatible with the router These steps are covered at the end of this section Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All
32. ocal Area Connection The Local Area Connection Status window appears see Figure 26 Step 5 is not applicable for Windows 98SE or ME Local Area Connection Status ag Papoa General Support Connection Status Connected Duration 00 00 11 Speed 100 0 Mbps Activity Figure 26 5 Click the Properties button to go to the Local Area Connection Properties screen see Figure 27 Step 6 is not applicable for Windows 98SE or ME Local Area Connection Properties General Advanced Connect using BB ICom EtherLink XL 10 100 PCI For Complete PC Manage Configure This connection uses the following items U EI Client for Microsoft Networks S File and Printer Sharing for Microsoft Networks QoS Packet Scheduler Figure 27 Internet Protocol TCP IP Install Properties Description Transmission Control Protocol Internet Protocol The default wide aiea nelwork protocol that provides communication ac oss diverse interconnected networks Show icon in notification area when connected OI s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com oO legrand 800 321 2343 Page 17 6 Ensure the box next to nternet Protocol TCP IP is selected see Figure 27 NOTE Although this series of steps is used to re configure the PC from direct WAP configuration back to its previous use as a DHCP controlle
33. ocol such as TCP used by the network that the data travels over An encapsulating protocol such as IPSec L2F L2TP or PPTP that is wrapped around the original data and A passenger protocol such as IP for the original data U UDP User Datagram Protocol A method used along with the IP to send data in the form of message units datagram between network devices over a LAN or WAN Unicast A point to point data transmission sent from one sender to one receiver This the normal way you access websites See also multicast USB Universal Serial Bus is a computer interface for add on devices such as printers scanners mice modems or keyboards USB 1 1 supports data transfer rates of 12 Mbps and plug and play installation You can connect up to 127 devices to a single USB port USB 2 0 supports data rates of 480 Mbps V VolP Voice over Internet Protocol is a method to exchange voice fax and other information over the Internet Voice and fax have traditionally been carried over traditional telephone lines of the Public Switched Telephone Network PSTN using a dedicated circuit for each line VoIP enables calls to travel as discrete data packets on shared lines VoIP is an important part of the convergence of computers telephones and television into a single integrated information network VPN A virtual private network is a private network that uses virtual connections tunnels routed over a public network usually the Int
34. omputer data to serial data in a packet format that it sends over the LAN A NIC is installed in an expansion slot or can be built in Every Ethernet NIC has a MAC address permanently saved in its ROM 0 oSI Open Systems Interconnection is the seven layer suite of protocols designed by the International Standards Organization ISO to be the international standard computer network architecture P Packet The unit of data that is routed between the sender and destination on the Internet or other packet switched network Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand en Page 29 PCMCIA The Personal Computer Memory Card International Association sets international standards for connecting peripherals to portable computers Laptop computers typically have a PCMCIA slot that can hold one or two PC Cards to provide features such as Ethernet connectivity PING A network utility that tests host reachability by sending a small packet to the host and waiting for a reply If you PING a computer IP address and receive a reply you know the computer is reachable over the network It also stands for Packet Inter Net Groper POE Power Over Ethernet is a technique used to supply low voltage operating power to devices connected with a twisted pair Cat 5e Ethernet interface cable Port Triggering A mechanism that allows inco
35. onO O legrand WIRELESS ACCESS POINT P N 364887 01 In Ceiling P N 364891 01 In Wall OWNER S MANUAL 1307877 REV O Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a class B digital device pursuant to Part 15 of the Federal Communications Commission FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures _ Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the rec
36. out the quotation marks Ol s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand i Page 11 NOTE Once you have logged in for security reasons you should change the Password Be sure to document the new Password For details on changing your Password see the Firmware Upgrade section C Wireless Security Setup Follow these procedures to setup the correct security protocols for your WAP 1 Select Simple Setup see Figure 17 Simple Setup Access Control Firmware Upgrade SSID AP_324cb7 Associated Stations Vv Response to Broadcast SSID requests Channel Channel 1 z Operation Mode mixed z Preamble Long z Authentication Method Open System or Shared Key z Encryption None O 54g Protection WEP Key 4 10 or 26 Default Key WPA Re key Timer Enable DHCP Use the wing IP Setting 192 168 1 1 255 255 255 0 Default Gateway Apply Restore Figure 17 8 The SSID Service Set Identifier field displays the SSID of this device You can change it to a more user friendly name and click on Apply at the bottom of the screen to make the change NOTE The SSID you choose will remain as selected unless the reset button is pressed which brings the unit back to its factory default settings 9 Enabling the Response to Broadcast SSID requests option allows the d
37. r block the airflow to the device with insulation or any other objects Keep the device away from excessive heat and humidity and keep the device free from vibration and dust Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand wm Page iii TABLE OF CONTENTS I Introduction ll Product Overview A Features B Components Included C Replacement Parts D Detailed Physical Description lll Installation A Rough In Steps B Trim Out Steps IV Configuration Steps A Configuring a Network Interface Card to talk to a WAP B Logging on to the WAP C Wireless Security Setup D Configuring the WAP to work with a Router E Allowing Client Access with MAC Addresses F Returning the PC to DHCP Control G Firmware Upgrades H Login Password Change VI Troubleshooting A Contact Information B Hardware Situations C Software Situations VII Glossary Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com oO legrand 800 321 2343 Page iv 11 12 15 16 16 19 19 20 20 20 23 25 I Introduction The On Q Legrand Wireless Access Point WAP 802 11g In Ceiling or In Wall unit shown in Figure 1 uses a radio transmission technology defined by the Institute of Electrical and Electronics Engineers IE
38. re Your Computers on how to adjust the IP address for your PC Verify that you can ping the WAP on this IP address In the Command window type ping and your WAP s default IP address and press Enter For example type ping 192 168 1 3 If you have changed the factory configured default IP address of the WAP you will need to set your network adapter accordingly Verify you are entering the correct URL in the browser The default is http 192 168 1 1 If you think you have changed the IP address used to configure the WAP and cannot remember it you must reset the unit back to factory defaults To do this press and hold the reset button under the cover for more the 5 seconds This clears the WAP s user settings including SSID Password IP Address and Subnet mask Once the WAP 802 114 is reset to factory default re verify the Ethernet connectivity and IP address issues Verify you are using the latest version of IE or Netscape IE 5 2 and below are not supported 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 Page 24 VII Glossary A Access Point AP A device that provides wireless LAN connectivity to wireless clients stations Adapter A device or card that connects a computer printer or other peripheral device to the network or to some other device A wireless adapter connects a computer to the wireless LAN Address translat
39. rol at the top center of the setup screen to go to the MAC Access Control page as shown in Figure 25 2 Select either Accept association requests from any station or Only allow Stations with MAC listed below to access this device in the MAC Filter Mode area see Figure 25 Simple Setup Access Control Firmware Upgrade MAC Filter Mode Only allow Stations with MAC listed below to access this device Stations allowed or denied to be associated Number MAC Address 1 2 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 0 00 00 00 00 00 Ann Figure 25 3 Enterthe MAC addresses of the clients you wish to be able to gain access to your On Q WAP 802 11g in the provided list and click on Apply NOTE The MAC address should be printed on the label on each wireless network adapter card that will be used to access the On Q WAP 802 119 F Returning the PC used to configure the WAP 802 11g to DHCP control 1 Click Start 2 Select Control Panel For Windows 98SE ME and 2000 select Settings first 3 Double click Network and Dial Up Connections Ol s Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand i Page 16 Double Click Network for Windows 98SE and ME and the Network Window is displayed 4 Double click L
40. rum as in Article 3 2 Testing for radio test suites according to EN 300 328 2 WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE THE UNIT MUST NOT BE EXPOSED TO DRIPPING OR SPLASHING WATER CAUTION DO NOT OPEN THE UNIT DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION THIS DEVICE MUST BE INSTALLED AND USED IN STRICT ACCORDANCE WITH THE MANUFACTURER S INSTRUCTIONS AS DESCRIBED IN THE USER DOCUMENTATION THAT COMES WITH THE PRODUCT WARNING POSTPONE INSTALLATION UNTIL THERE IS NO RISK OF THUNDERSTORM OR LIGHTNING ACTIVITY IN THE AREA When using this device basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following e Read all of the instructions listed here and or in the user manual before you operate this equipment e Give particular attention to all safety precautions Retain the instructions for future reference Comply with all warning and caution statements in the instructions Observe all warning and caution symbols that are affixed to this equipment Comply with all instructions that accompany this equipment Avoid using this product during an electrical storm There may be a risk of electric shock from lightning For added protection for this product during a lightning storm or when i
41. s e Direct line of sight achieves better performance but obviously is not always achievable e Try to avoid placing the WAP next to large solid or dense objects like walls fireplaces etc This helps the signal penetrate more cleanly e Other wireless devices like televisions radios microwaves and 2 4 GHz cordless telephones can interfere with the signal Keep devices away from the unit e Mirrors especially silver coated negatively affect transmission performance Your On Q WAP 802 11g is powered over the single Cat 5e cable that connects it to the service provider A power supply inserts power onto the Cat 5e cable through an inserter module and then this power is extracted for use at the WAP location In this way unsightly power cables are avoided at the WAP location Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onglegrand com 800 321 2343 O legrand wm Page 1 ll Product Overview A Features e Compatibility with both 802 11g and 802 11b standards e Wireless security via Wired Equivalent Privacy WEP and WiFi Protected Access WPA encryptions e Firmware upgrades available to stay current with latest specification Components Included The On Q WAP 802 11g either In Ceiling or In Wall version includes the following components e WAP Assembly WAP Cover WAP 24VDC Power Supply with AC cord WAP Power Over Cat 5e Inserter Module Cat
42. s where a data signal at the sending station is combined with a higher data rate bit sequence or chipping code that divides the user data according to a spreading ratio The chipping code is a redundant bit pattern for each bit that is transmitted which increases the signal s resistance to interference If one or more bits in the pattern are damaged during transmission the original data can be recovered due to the redundancy of the transmission Dynamic IP Address An IP address that is temporarily leased to a host by a DHCP server The opposite of Static IP Address E ESS An Extended Service Set ESS is a set of two or more BSSs that form a single subnetwork See also BSS Ethernet The most widely used LAN type also known as IEEE 802 3 The most common Ethernet networks are 10Base T which provide transmission speeds up to 10 Mbps usually over unshielded twisted pair wire terminated with RJ 45 connectors Fast Ethernet 100Base T provides speeds up to 100 Mbps Base means baseband technology and T means twisted pair cable Each Ethernet port has a physical address called the MAC address Also see MAC address Event A message generated by a device to inform an operator or the network management system that something has occurred F Firmware Code written onto read only memory ROM or programmable read only memory PROM Once firmware has been written onto the ROM or PROM it is retained even when the device is turned off
43. sed IP addresses DMZ DeMilitarized Zone This service opens one IP address to the Internet usually for online gaming and acts as a buffer between the Internet and your network DNS The Domain Name System is the Internet system for converting domain names like www onqlegrand com to IP addresses A DNS server contains a table matching domain names such as Internetname com to IP addresses such as 192 169 9 1 When you access the world wide web a DNS server translates the URL displayed on the browser to the destination website IP address The DNS lookup table is a distributed Internet database no one DNS server lists all domain name to IP address matches Domain Name A unique name such as onghome com that maps to an IP address Domain names are typically much easier to remember than are IP addresses See DNS Download To copy a file from one computer to another You can use the Internet to download files from a server to a computer Ol Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 800 321 2343 O legrand i Page 26 Driver Software that enables a computer to interact with a network or other device For example there are drivers for printers monitors graphics adapters modems Ethernet USB and many others DSL Digital Subscriber Line DSSS Direct Sequence Spread Spectrum DSSS is a transmission technology used in WLAN transmission
44. t is left unattended and unused for long periods of time unplug the power supply and disconnect the Cat 5e to the WAP at the Power Inserter This will prevent damage to the product due to lightning and power surges It is recommended that the customer install an AC surge protector in the AC outlet to which this device is connected This is to avoid damaging the equipment by local lightning strikes and other electrical surges A Data Surge Conditioning Unit is also available from On Q Legrand 364598 01 to help protect the data connection from the Power Injector to the WAP Operate this product only from the type of power source indicated on the product s marking label If you are not sure of the type of power supplied to your home consult your dealer or local power company Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in safe operating condition Installation of this product must be in accordance with national wiring codes and conform to local regulations Place Power Inserter to allow for easy access when disconnecting the power cord adapter of the device from the AC wall outlet Wipe the unit with a clean dry cloth Never use cleaning fluid or similar chemicals Do not spray cleaners directly on the unit or use forced air to remove dust When not utilizing the recommended 3 gang plastic switch amp outlet box do not directly cover the device o
45. the WAP 802 11g to factory defaults as follows Factory SSID Responds to broadcast SSID requests Channel 1 operation Mixed Operation Mode Automatic Transmit Rate Long Preamble Open System Authentication Method No Encryption Accept requests from any stations Default IP Address 192 168 1 1 Figure 32 NOTE Prior to performing Step 4 below remove AC power from the Power Inserter in the On Q Enclosure 4 WAP 802 11g Cabling Verification Once the WAP 802 11g Assembly has been removed from the 3 gang box as shown in Figure 31 look at the back of the assembly to insure the Cat 5e cable from the enclosure is properly terminated see Figure 33 and plugged into the Input jack as shown in Figure 34 Also insure the rest of the factory cabling is plugged in as shown Then replace the assembly back in the 3 gang box and replace the cover OI Q 301 Fulling Mill Road Suite G Copyright 2005 by On Q Legrand Inc All Rights Reserved Middletown PA 17057 www onqlegrand com 0 legrand 800 321 2343 Page 21 Figure 33 Figure 34 5 My computer is experiencing difficulty connecting to the wireless network a Ensure that your On Q WAP 802 11g is powered on and that the Wireless LED is lit see Figure 30 b Ensure that your wireless adapter PCI card Notebook or Ethernet adapter is installed correctly and is active c Ensure that your wireless adapter s radio signal is enabled and set to the same channel on
46. vanced Connect using B ICom EtherLink XL 10 100 PCI For Complete PC Manage This connection uses the following items M Bl Cient for Microsoft Networks MI Fils and Printer Sharing for Microsoft Networks M iE QoS Packet Scheduler M 3 Internet Protocol TCP IP Install t Properties Description Transmission Control Protocol nternet Protocol The default wide area network protocol that provides communication acioss diverse interconnected networks Show icon in notification area when connected ee oc Figure 13 6 Ensure the box next to Internet Protocol TCP IP is selected see Figure 13 7 Click to highlight Internet Protocol TCP IP and click the Properties button to go to the Internet Protocol TCP IP Properties screen For Windows 98SE or ME from the Network Window s configuration tab select the TCP IP line the for the appropriate Ethernet adapter and Click Properties From the TCP IP Properties Window Click on the IP Address tab Internet Protocol TCP IP Properties 2 x General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 10 Subnet mask 25 255 255 0 Default gateway R j i Obtain DNS er address automatically Use the