1. omy H SY Intellisense Note After the reading have been deleted the screen to the right of the illustration above appears and Memory symbol flashes Release the buttons to return to the memory display 17 4 Quick Reference Guide Use this as a quick reference guide only If you are using this device for the first time please read carefully Chapter 3 of this Instruction Manual Avoid eating drinking smoking or exercising for at least 30 minutes before taking a measurement You should also try to measure your blood pressure at the same time each day It is recommended that you check your blood pressure at least twice a day in the morning before breakfast and in the evening before going to bed Measurement should be taken in a quiet place and you should be in a relaxed seated position 1 Align the wrist cuff with the level of your heart and gently support your left arm with your right hand Do not place your right hand on the cuff itself 2 Press the O I START button Remain quiet sit still and do not talk during the measurement Notes e Always wait at least 2 3 minutes before taking another blood pressure measurement You may require more rest time between measurements depending on your individual physiological characteristics Only use the R2 to measure your own blood pressure to avoid confusion as the results of measurements are stored in memory Always wrap the wrist cuff around
2. VVrist Blood Pressure Monitor Model R2 e Instruction Manual e Mode d emploi Gebrauchsanweisung e Manuale di istruzioni e Manual de instrucciones s Gebruiksaanwijzing e PYKOBOJICTBO NO SKCNJTYATALINVN Cal uit AU for Healthcare IM HEM 6113 E V 02 10 2011 5330293 3B Contents introduction acilia Liliana 3 Important Safety Information 4 1 OVEFVION acli 6 2 Prepara snoa 9 2 1 InstallingjReplacing the Batteries 9 3 USING ENO UNIE ssscccicedasosdedeiiedicenanssantuhetacasnce 11 3 1 Applying the Wrist Cuff 11 3 2 Correct Posture neto sore nse mini n nash 13 3 3 Taking a Reading _ 14 3 4 Using the Memory Function 16 4 Quick Reference Guide 18 5 Handling Errors and Problems 19 5 1 Error Messages 19 5 2 Troubleshooting eee 20 6 Maintenance and Storage 22 Te Technical Data 24 8 Some Useful Information about Blood PRESSUNO siana iaaa 27 Introduction Thank you for purchasing the OMRON R2 Wrist Blood Pressure Monitor This remarkable compact and easy to use instrumentis ideal for people who frequently monitor their own blood pressure The small pre formed wrist cuff is very convenient and easy to apply With a push of a button the OMRON VVrist Blood Pressure
3. airplane 4 Important Safety Information Battery Usage If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water Use only two AAA alkaline batteries with this unit Do not use other types of batteries Do not insert the batteries with their polarities incorrectly aligned e Replace old batteries with new ones immediately Replace both batteries at the same time e Remove the batteries if the unit will not be used for three months or more Do not use new and used batteries together General Precautions Do not apply strong shocks and vibrations to or drop the unit Do not take measurements after bathing drinking alcohol smoking exercising or eating Do not inflate the wrist cuff when it is not wrapped around your wrist Do not wash the wrist cuff or immerse it in water Read and follow the Important information regarding Electro Magnetic Compatibility EMC Y in the Technical Data Section EN Read and follow the Correct Disposal of This Product in the Technical Data Section when disposing of the device and any used accessories or optional parts 1 Overvievv Main Unit C VVrist cuff D O I START button E MEM Memory button A Display B Battery compartment cover Display ION 1 Overview Systolic blood pressure Diastolic blood pressure Memory symbol Displayed when viewing values stored in memory Batt
4. Monitor measures your blood pressure and pulse and displays the reading on a clear digital panel Perfect for quick easy readings at home at work and while travelling It also stores up to 30 sets of measurement results in memory The OMRON Wrist Blood Pressure Monitor uses the oscillometric method of blood pressure measurement This means the unit detects the pulse wave vibrations in the artery of your wrist and converts the oscillations into a digital reading For comfortable controlled inflation without the need of pressure pre setting or re inflation the device uses its advanced Intellisense technology Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm Changes in wrist blood pressure reflect changes in arm blood pressure because the arteries in the wrist and the arm are connected Frequently measuring the blood pressure in your wrist will provide you and your doctor with an accurate indication of changes in your true blood pressure Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated wrist cuff following the instructions in this instruction manual It is mainly designed for general household use Please read the Important Safety Information in this instruction manual before using the unit Ba Please read this instruction manual thoroughly before using the unit For specific informat
5. mbH Subsidiary John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANT FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Made in Vietnam 29 Notes 30
6. azardous substances 8 Some Useful Information about Blood Pressure What is Blood Pressure Blood pressure is a measure of the force of blood flowing against the walls of the arteries Arterial blood pressure is constantly changing during the course of the hearts cycle The highest pressure in the cycle is called the Systolic Blood Pressure the lowest is the Diastolic Blood Pressure Both pressure readings the Systolic and Diastolic are necessary to enable a doctor to evaluate the status of a patients blood pressure Why is it a Good Thing to measure Blood Pressure at Home Having your blood pressure measured by a doctor can cause anxiety which is itself a cause of high blood pressure As a variety of conditions affect blood pressure a single measurement may not be sufficient for an accurate diagnosis Many factors such as physical activity anxiety or the time of day can influence your blood pressure Thus it is best to try and measure your blood pressure at the same time each day to get an accurate indication of any changes in blood pressure Blood EN pressure is typically lovv in the morning and increases from afternoon to evening It is lower in the summer and higher in the winter Blood pressure is measured in millimetres of mercury mmHg and measurements are written with the systolic pressure before the diastolic e g A blood pressure written as 135 85 is referred to as 135 over 85 mmHg 27 8 Some Useful Inf
7. be able to use the unit for a short while You should replace the batteries with new ones as soon as possible When the symbol x remains lit the batteries are exhausted You should replace the batteries with new ones at once Turn the unit off before replacing the batteries Remove the batteries if the unit will not be used for three months or more Dispose of batteries according to applicable local regulations e Two new identical 1 5V AAA alkaline batteries will last for approximately 300 measurements when used to take two measurements a day Since the supplied batteries are for monitoring use only they may have a shorter life and do not last for 300 measurements 3 Using the Unit 3 1 Applying the Wrist Cuff You can take a measurement on either your left or right wrist Notes You can take a measurement on either your left or right arm The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different Omron recommends to always use the same arm for measurement If the values between the two arms differ substantially please check with your physician which arm to use for your measurement To ensure correct measurement apply the wrist cuff so that it fits comfortably around your wrist Do not apply over clothing 1 Place the wrist cuff over your left wrist with your left thumb facing upward Note Make sure that the
8. c products e Type B fees CE 0197 This device fulfils the provisions of EC directive 93 42 EEC Medical Device Directive This blood pressure monitor is designed according to the European Standard EN1060 Non invasive sphygmomanometers Part 1 General Requirements and Part 3 Supplementary requirements for electromechanical blood pressure measuring systems li Caution Please read the instruction manual carefully before using the device 25 7 Technical Data Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situations the EN60601 1 2 2007 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed Do not
9. eading Remain still and do not talk during measurement Refer to 3 3 Taking a Reading Consult your OMRON retail outlet or distributor Apply the cuff correctly so that it is securely wrapped around the wrist Refer to 3 1 Applying the VVrist Cuff 5 Handling Errors and Problems The blood pressure is different each time The reading is extremely low or high The unit loses power during measurement Nothing happens when you press the buttons Other problems The batteries are drained The batteries are drained The batteries have been inserted incorrectly Blood pressure readings constantly vary with time of day and how relaxed you are Take several deep breaths and try to remain relaxed before taking a measurement Replace the batteries with new ones Replace the batteries with new ones Insert the batteries with the correct polarity Press the O I START button and repeat measurement e If the problem continues try replacing the batteries with new ones If this still does not solve the problem contact your OMRON retail outlet or distributor 21 6 Maintenance and Storage To protect your unit from damage please avoid the following Subjecting your unit to extreme temperatures humidity or direct sunlight Washing the cuff or exposing the cuff or unit to water e Disassembling the unit Subjecting the unit to strong s
10. ery low symbol J Heartbeat symbol 1 2 Flashes during measurement If flashing after measurement completed or when viewing results stored in the memory indicates blood pressure out of recommended K Pulse L Deflation symbol EN Note If your systolic or diastolic pressure is outside the standard range above 135 85 mmHg the Heartbeat symbol 4 will blink Please refer to 3 3 Taking a Reading 1 Overvievv Package contents N WU Q M Two AAA alkaline LRO3 N Storage case batteries e Blood pressure pass e Instruction manual Blood Pressure Monitor unit e Guarantee card 2 Preparation 2 1 InstallingjReplacing the Batteries 1 Remove the battery compartment cover by pulling it off in the direction of the arrow 1 Push the hook on the bottom of the battery cover 2 Pull the cover off the main unit 2 Insert two identical 1 5V AAA alkaline LRO3 batteries in the battery compartment Make sure their polarity is aligned with the polarity as indicated in the battery compartment 2 Preparation 3 Put the battery cover back in place Note The measurement values continue to be stored in memory even after the batteries are replaced Battery Life amp Replacement 10 If the battery low symbol 441 appears on the display replace both batteries at the same time When the battery low symbol 441 starts to blink you will still
11. esults Relax your wrist and hand Do not clench Do not bend your your vvrist back your fist wrist forward 3 Using the Unit 3 3 Taking a Reading 1 14 Press the O I START button to start measurement Q Intellisense The wrist cuff will start to inflate automatically after the power is turned on After the unit has detected your blood pressure and pulse rate the cuff automatically deflates and your blood pressure and pulse rate are displayed Notes e Sit still and do not talk or move until the measurement is completed Keep the unit at heart height until the measurement is completed e To stop measurement press the O I START button at any time during measurement 3 Using the Unit Check the measurement result CO i SY Intellisense The unit automatically stores blood 1 IS pressure and pulse rate into its memory I Refer to 3 4 Using the Memory Function Undo the cuff and remove the unit Press the O I START button to turn off the unit If you forget to turn off the unit it will shut itself off automatically after two minutes Important e If your systolic or diastolic pressure is outside the standard range the AL heartbeat symbol will blink when the E measurement result is displayed mm Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home Above 135 mmHg Ab
12. hocks or vibrations Dropping the Unit Cleaning the unit with volatile liquids The unit should be cleaned with a soft dry cloth Use a soft moistened cloth and soap to clean the cuff e Keep the unit in its storage case when not in use Fold the cuff into the storage case Do not store the unit in the following situations e If the unit is wet Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapours Locations exposed to vibrations shocks or where it will be at risk of falling 22 6 Maintenance and Storage Calibration and Service e The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy Please consult your authorised OMRON dealer or the OMRON Customer Service at the address given on the packaging or attached literature e If the wrist cuff needs to be replaced have this done by an authorised expert Consult your authorised OMRON dealer or the OMRON Customer Service Do not carry out any repairs by yourself If a defect occurs or you have doubts about the correct functioning of the device consult your authorised OMRON dealer or the OMRON Customer Service 23 7 Technical Data Product Description Model Display Measurement Measurement Range Memory Accuracy Inflation Def
13. ion about your own blood pressure CONSULT YOUR DOCTOR 3 Important Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis Please read this section carefully before using the unit ZN Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury General Usage e Always consult your doctor Self diagnosis of measurement results and self treatment are dangerous People with severe blood flow problems or blood disorders should consult a doctor before using the unit as cuff inflation can cause internal bleeding Battery Usage If battery fluid should get in your eyes immediately rinse with plenty of clean water Consult a doctor immediately AN Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property General Usage Do not leave the unit unattended with infants or persons who cannot express their consent Do not use the unit for any purpose other than measuring blood pressure Do not disassemble the unit or wrist cuff Do not inflate the wrist cuff over 299 mmHg Do not use a mobile phone or other devices that emit electromagnetic fields near the unit This may result in incorrect operation of the unit Do not operate unit in a moving vehicle car
14. lation Power Source Battery Life Operating Temperature Humidity Storage Temperature Humidity Weight of Main Unit Outer Dimensions Measurable circumference of wrist Cuff material Package Content VVrist Blood Pressure Monitor OMRON R2 HEM 6113 E V 1 HEM 6113 E8 V LCD Digital Display Oscillometric method Pressure 0 to 299 mmHg Pulse 40 to 180 beats min 30 Measurements Pressure Within 3 mmHg Pulse rate Within 5 of reading Automatic inflation by pump Automatic rapid deflation Two 1 5V AAA alkaline LR03 batteries Approximately 300 measurements when used twice daily with alkaline batteries at a room temperature of 23 C 10 C to 40 C 30 to 85 RH 20 C to 60 C 10 to 95 RH Approximately 117 g not including batteries 71 mm w x 41 mm h x 70 mm d not including the wrist cuff Approximately 13 5 to 21 5 cm Nylon Main unit storage case two AAA alkaline LR03 batteries instruction manual guarantee card blood pressure pass Note Subject to technical modification without prior notice 24 7 Technical Data This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co Ltd Japan The Core component for OMRON blood pressure monitors which is the Pressure Sensor is produced in Japan Disposal of this product and used batteries should be carried out in accordance with the national regulations for the disposal of electroni
15. ormation about Blood Pressure 200 Upper curve systolic blood pressure Lower curve diastolic blood pressure mmHg o Ga O O T T 6 12 18 24 Time of day Example fluctuation within a day male 35 years old Classification of Blood Pressure by the World Heath Organization The World Health Organization WHO and the International Society of Hypertension ISH developed the Blood Pressure Classification shown in this figure Systolic blood pressure mmHg Severe hypertension 180 Moderate hypertension 160 Mild hypertension 0 Normal systolic value 130 Normal blood ure 120 Optimal blood pressure Diastolic target value blood 80 85 90 100 110 pressure mmHg This classification is based on the blood pressure values measured on people in a sitting position in outpatient departments of hospitals There is no universally accepted definition of hypotension However those having the systolic pressure below 100 mmHg are assumed as hypotensive 28 Manufacturer OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN EU representative OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp REP THE NETHERLANDS www omron healthcare com OMRON HEALTHCARE Production facility MANUFACTURING VIETNAM CO LTD Binh Duong Province VIETNAM OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 ODG U K OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT
16. ove 85 mmHg This criteria is for home blood pressure measurement For professional office blood pressure measurement criteria please refer to Classification of Blood Pressure by the World Heath Organization refer to 8 Some Useful Information about Blood Pressure 15 3 Using the Unit 3 4 Using the Memory Function This unit has a memory capable of storing 30 sets of readings Every time you complete the measurement the unit automatically stores blood pressure and pulse rate Note When 30 sets of readings are stored in memory the oldest set will be deleted to store a new set To View Previous Readings Stored in Memory 1 16 Press the MEM button to view readings stored in memory from the most recent to the oldest The Memory number appears for a second before the pulse rate is displayed The newest set is numbered 1 om i YW Intellisense Press the MEM button repeatedly to cycle through the readings Press the O I START button to turn the unit off Note If you forget to turn the unit off it will automatically shut itself off after two minutes 3 Using the Unit To Delete All Values in Memory You cannot delete the stored readings partially all the readings in the unit will be deleted To delete stored readings first press the MEM button Then while holding it down press the O I START button simultaneously for about 2 3 seconds All readings will then be deleted
17. use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near the medical device This may result in incorrect operation of the unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shorter Further documentation in accordance with EN60601 1 2 2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com Correct Disposal of This Product Waste Electrical amp Electronic Equipment ad This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of wnere and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal This product does not contain any h
18. wrist cuff does not cover the protruding part of the wrist bone ulna on the outside of the wrist 11 3 Using the Unit 2 Hold the bottom part of the wrist cuff and wrap it around the wrist vvhile pulling so that it fits comfortably Notes Unless the wrist cuff is wrapped 7 securely around the wrist it will not be possible to take correct measurements If you have a slender wrist the cuff may feel slightly loose a However this will not affect measurement results and you should not force the cuff to fit The remaining part of the wrist cuff can be conveniently folded back out of the way If the remaining part of the cuff is difficult to fold back measurement results will not be effected Taking a reading on the right wrist Measurements can also be made on the right wrist Fit the unit on the right wrist as shown 12 3 Using the Unit 3 2 Correct Posture Correct posture during measurement helps you get accurate results You should also try to measure your blood pressure at the same time each day Notes Do not take measurement after bathing drinking alcohol or exercising Do not move or talk during measurement Sit comfortably with your back straight Position your arm so that hold your arm across the unit is at the same your chest and relax level as your heart Do not use your other hand to support the wrist cuff This can result in inaccurate measurement r
19. your wrist before starting to take a measurement e Always measure your blood pressure on the same wrist 18 5 Handling Errors and Problems 5 1 Error Symbol i ax Blinks or appears continuously Error Messages Cause Cuff over inflated Movement during measurement The wrist cuff is not fastened securely An E mark with a code number indicates the device has a hardware failure The battery power is low Correction Repeat measurement Remain still and do not move during measurement Refer to 3 3 Taking a Reading Carefully read and repeat the steps listed under 3 1 Applying the Wrist Cuff Consult your OMRON retail outlet or distributor Replace the batteries with two new AAA alkaline LRO3 batteries 19 5 Handling Errors and Problems 5 2 Troubleshooting The reading is extremely low or high VVrist cuff pressure does not rise VVrist cuff deflates too soon 20 Are you holding the wrist cuff at heart level Is the cuff wrapped snugly around the wrist Are your arms and shoulders tense Movement or talking during measurement Air is leaking from the wrist cuff The wrist cuff is loose Measure while in the correct posture Refer to 3 2 Correct Posture Wrap the cuff correctly Refer to 3 1 Applying the Wrist Cuff Relax and try taking the measurement again Refer to 3 3 Taking a R