Omron Healthcare INTELLISENSE HEM-907XL User's Manual
Contents
1. Cuff bladder set Medium with built in bladder Model HEM 907 CR19 Applicable arm circumference 9 to 13 22 to 32 cm Cuff bladder set Small with built in bladder Model HEM 907 CS19 Applicable arm circumference 7 to 9 17 to 22 cm Instruction Manual OMRON INSTRUCTION MANUAL IntelliSense Blood Pressure Monitor Qeli M Items identified with an asterisk are consumables and not covered by the guarantee 8 COMPONENTS OF THE PRODUCT Options not included Cuffs without bladder Extra Large Cuff For use with the HEM 907XL only Model HEM 907 CUFFX Large Cuff Model HEM 907 CUFFL Medium Cuff Model HEM 907 CUFFM Small Cuff Model HEM 907 CUFFS The air tube is available for the large medium or small size cuff It is NOT for use with the extra large cuff size Wall hanging kit Model HEM 907 WKIT Exclusive Stand Model HEM 907 STAND Bladders Air tube 1 3 m 51 1 6 Model HEM TUBE 130 Pole mounting kit Model HEM 907 PKIT Extra Large Bladder For use with the HEM 907XL only Model HEM 907 BLDRX Large Bladder Model HEM 907 BLDRL Medium Bladder Model HEM 907 BLDRM Small Bladder Model HEM 907 BLDRS Items identified with an asterisk are consumables and not covered by the guarantee Accessories and options are subject to change without prior notice FEATURES AND FUNCTIONS Names
2. Matters involving actual prohibitions are indicated by text or pictures in or near The pictured icon refers to prohibition to disassemble The icon indicates something that is compulsory always follow Matters involving actual compulsory actions are indicated by text or pictures in or near The pictured icon refers to unplugging the power source plug Self diagnosis of measured results or treatment is dangerous Please follow the instruction of the doctor or healthcare provider A Oe If cuff inflation does not stop remove the cuff or pull out the air tube from the main unit If battery fluid gets into your eye or comes in contact with skin wash the effected area with water repeatedly Immediately consult a doctor for treatment Do not wrap the cuff over an arm to which intravenous injection or transfusion is being conducted or when otherwise contraindicated Do not connect the air tube or the cuff to other equipment which is connected to an intracorporeal organ Air embolisms may result Do not use this unit in the presence of flammable gas or anesthetics or in a 1 The product and contents of this Instruction Manual may be changed without prior notice high pressure oxygen room or oxygen tent We have prepared the contents of this Instruction Manual thoroughly However if an inadequate description or error is found please let us know Do not use the battery pack for devices other than for th
3. 6 Push the START Button to start the ja measurement c5 pP a e Do not push the START Button without ms J O wrapping the cuff Auf ewen m e Do not squeeze or press the cuff during ee the measurement e If you want to inflate again after the start of deflation push the START Button e If you want to accelerate deflation after the of Ne O Nor 2 Set the MODE Selector to MANU start of deflation push the DEFLATION iO Pulse deflation control Measurement Results m Display Switch Button Each time the abd Button is pushed cuff is deflated rapidly in A mny increments of 5 to 10 mmHg uy CHARGING AC J EXTERNAL START Op 7 Take the readings m g mmHg Ruj Jeres 8 Push the STOP Button to remove air inside the cuff 3 Set the P SET inflation level setting Theunitdoss horauiomalioall y deflate In P SET MODE Knob to AUTO or the target the MANU Mode EE pressure value Y Gm Z m LI mmHg a E 9 Push the ON OFF power Button to H fac amna turn off the power one 4 Measure the patient s arm size and a Jo IN i ff over the wrap appropriate cu If the monitor determines that the pressure JA a gta patient s arm Refer to pages 14 value is not correct an error display appears CF C and 15 Eri to 9 In this case refer to Page 28 and start the
4. measurement again 24 25 HOW TO CHECK HOW TO CLEAN THE UNIT AFTER USE PRESSURE ACCURACY IN CHECK MODE General advice A Caution When cleaning this unit unplug the AC adapter from the electric outlet e Do not clean this unit with gasoline paint thinner or high concentration alcohol e Do not disinfect this unit by autoclave or gas steril ization EtO gluteraldehyde or high concentration ozone Accuracy of pressure display can be checked in the CHECK Mode What you need to prepare After cleaning this unit dry it well before plugging the AC adapter in the electric outlet 1 Calibrated mercury manometer including inflation bulb 2 T tube 3 two air tubes and 4 a sturdy cylindrical shaped object on which the cuff is wrapped o 1 Wipe the monitor with a soft damp cloth diluted with disinfectant alcohol or diluted detergent 2 Complete cleaning by wiping the monitor with a soft dry cloth How to check 1 Connect the manometer inflation bulb cuff and the monitor with the T tube as shown in the figure on the right 2 Tightly wrap the cuff over a sturdy cylinder I si 3 Release the valve of inflation bulb to remove the air inside the cuff completely 4 Push the ON OFF power Button to turn on the monitor 5 Set the MODE Selector to CHECK 6 Close the valve of inflation bulb and inflate the cuff to the pressur
5. not install or store this unit where it may Do not use the battery pack for devices other Do not touch the AC adapter with wet hands AN Come in popia wt WAS Gr guid medioan AN than for this unit This is a Class II device with double isolation Earth pin is not for protective purposes Do not disassemble the battery pack General advice f 1 Remove both screws on the upper portion of e Read the instruction manual of the other devices the battery cover of this unit and remove to be used at the same time with this unit to the cover understand and be aware of the interaction between the devices 2 Disconnect the old battery pack from the connector and replace with a new one 3 Install the battery cover and fasten it with both screws Be careful not to pinch the lead wire 4 Connect the main unit to the AC adapter to Connect the AC adapter to the DC jack of the main unit 1 and the electric outlet 2 Scena de etn ee ae PE TE T tial time charge it for more than twelve hours before use NOTE When the AC adapter is connected and the unit is turned off the AC adapter charges the installed rechargeable battery 16 tx Battery life HOW TO USE THE POWER SOURCE HOW TO MEASURE BLOOD PRESSURE e You can use the unit for approximately three hundred measurements with one charge e Approximate life of battery is two years However the battery life from each charging ma
6. of the Parts 1 Display See Page 11 for detail 6 ON OFF power 2 HIDE non display Button Button 7 START Button 8 DEFLATION deflation control Measurement Result Display Switch Button 9 Air Connector 4 P SET pressure setting Knob 10 STOP Button 5 MODE Selector 1 Display Displays blood pressure and pulse rate readings and oscillation pulse level 2 HIDE Button Switches display and non display of measured results 3 DC jack Connects the AC adapter 4 P SET pressure setting Knob In the AUTO position inflation level is automatically set Otherwise inflation level can optionally be set manually between 100 and 280 mmHg 5 MODE Selector Selects the operation mode One time Measurement Mode SINGLE Mode Measurement with automatic inflation Average Mode AVG Mode Automatically measures two or three times consecutively e Auscultation Mode MANU Mode Automatic inflation automatic deflation and pressure display for auscultation does not measure blood pressure e Check Mode CHECK Mode Checks the accuracy of pressure display Displays only pressure 6 ON OFF power Button Turns on or off the unit 7 START Button Starts the measurement 8 DEFLATION deflation control Measurement Result Display Switch Button e In the MANU Mode deflates the cuff by approximately 5 to 10 mmHg with each push during deflation e In the AVG Mode switches the display of average v
7. FETY e The warning signs and the sample icons shown here are listed to insure safe and accurate use OMRON does not accept liability and warranty becomes void under the following The icons and meanings are as follows circumstances Warning sign Contents When persons not authorized by OMRON perform repairs or modifications of this Warnin Indicates matters in which death or severe bodily damage may arise as a result product g of incorrect handling When use and or operation of this device is adversely effected by a device not A Caution Indicates matters in which bodily harm or material damage may arise as a manufactured by OMRON result of incorrect handling When use and or operation of this device is adversely effected by use of parts not Material damage refers to a wide range of damage involving your house household goods domestic animals and pets authorized by OMRON to repair or modify this product Examples of signs The A icon indicates caution including warning and danger Matters involving actual caution are indicated by text or pictures in or near 4 The pictured icon refers to caution for flammability 4 When Notes on Safety or Instructions for Use contained in this manual are not followed When use and or operation of this device is effected by an act of God such as fire earthquake flood or other natural disasters The O icon indicates prohibitions what you cannot do
8. Mode Inflation evel set AUTO Automatic setting Can be used when the SINGLE AVG or MANU Mode is selected x A r i Non display func The unit estimates the systolic blood pressure during inflation and inflates to a proper cuff pressure tion approximately 30 40 mmHg above the patient s systolic pressure Manual deflation ES Manual level setting Inflation level can be set manually between 100 and 280 mmHg Set the pa level to 30 to 40 mmHg higher than the expected systolic pressure 4 AVG Function setting e To set the P SET to AUTO turn the P SET Knob counterclockwise as far as it goes until you can hear a click a e In the AUTO setting inflation level may not be set automatically when the systolic blood pressure is more than You can set the number of measurements the waiting time until the 1st measurement and the 220 mmHg Use the unit in the manual setting measurement interval for the AVG Mode e If the cuff has not been inflated to the necessary level it may be re inflated automatically Function Items to set Set value F1 Number of measurements 2 times or 3 times F2 Waiting time until the start of 1st measurement 0 sec 3 min 5 min or 10 min F3 Measurement interval 5 sec 30 sec 1 min or 2 min 2 Non display function eE Note The bold letters represent the factory set values Use to prohibit the display of measurement results Howev
9. OMRON INSTRUCTION MANUAL IntelliSense Blood Pressure Monitor 4 WA Intelli ys vos TEM 907 XL UA Lr IET Thank you for purchasing the OMRON IntelliSense Blood Pressure Monitor Please thoroughly read this Instruction Manual before using this monitor to ensure safe and accurate use Please keep this manual near the monitor all the time for future reference Table of Contents Be Sure to Read This Section ExemplonS socorrir 2 Notes on Safety 0 cceeeeeceeeeeeees 3 Know Your Unit Features of the Product 000 7 Components of the Product 8 ODUOMS E E 9 Features and Functions 10 Names of the Parts eeee 10 Functions and setting while the unit is in uS 12 Preparations before Measurement How to Apply the Cuff 14 How to Use the Power Source 16 How to Use the AC Adapter 16 Installation and Replacement of Battery Pack seese 17 How to Measure Blood Pressure List of Measurement Modes 19 SINGLE Mode ccccceceeeeeeeeeees 20 AVG Mode cece cece eee eeeseeeenereees 22 MANU MOUE intiena 24 How to Check Pressure Accuracy 26 How to Clean the Unit after Use 27 List of Error Codes ccecceceeeeees 28 Troubleshooting 29 Specifications Gauto Mimika nednn anaia 30 Five Year Limited Warranty 31 Specifications s es 31 FS ONS NOTES ON SA
10. alues and the measurement results with each push 9 Air Connector Connects the air tube 10 STOP Button Stops the measurement and deflates air rapidly 10 FEATURES AND FUNCTIONS DIG IEN Systolic blood pressure Ready to Measure Pulse synchronization Diastolic blood pressure p Pulse level Number of irregular pulses Number of irregular pulse waves The pulse wave having a difference of more than 25 from the average interval of pulse waves is determined irregular Number of irregular pulse waves is displayed up to three times r READY TO MEASURE aTa fa boo mmHg f Example of display DIA No of irregular pulses 2 BATTERY D d m f a G f n ao O Displays a for the operable level N l A Blinks gamy for a low charged 7 level Displays for the inoperable Contents when the AVG pays d level j Mode is selected AVG Mean value st First reading 2nd Second reading 3rd Third reading Pulse rate Charging Displays gt A when the battery pack is being charged External power source Displays AC when the unit is connected to the external power source via the AC adapter 11 FEATURES AND FUNCTIONS FEATURES AND FUNCTIONS List of Functions for each Mode Fu nctions setting Measurement Mode Single SINGLE Average Auscultation Check Function 1 Inflation level setting P SET Mod AVG Mode MANU Mode CHECK
11. ar phone near this unit Do not use this unit in a vehicle S SINGLE Mode m ii AVG Mode Refer to Page 20 Refer to Page 22 Refer to Page 24 HOW TO MEASURE HOW TO MEASURE BLOOD PRESSURE IN SINGLE MODE BLOOD PRESSURE IN SINGLE MODE 5 Push the START Button to start the es 1 Push the ON OFF power Button to measurement 25 turn on the power Do not push the a coo viele START Button without Pasa EEMAL wrapping the cuff If you want to stop eS measurement push A ae the STOP Button The aon EPR AD on cuff will rapidly CD fo deflate l k T 6 The measurement results are oe 2 Set the MODE Selector to SINGLE purse displayed MEASURE e While the battery pack is in use the a e monitor will turn off automatically after PULSE vale five minutes of inactivity and the display measurement results will disappear L Automatic Power Off ee l l 7 Push the ON OFF power Button to 3 Set the P SET inflation level Knob turn off the power to AUTO or to the target pressure TT rue oe value n EXTERNAL BATTERY AB leat ih Noo Te L QA 280 E eee 4 Measure the patient s arm size and wrap appropriate cuff over the If the monitor determines t
12. cuff as shown in the Figure on the right TUBE Extract the air tube from Air tube Enlarged figure of the circled part Air connector 2 Connect the air tube securely Air plug To use the cuff in small medium or large size _ ff p e Connect the air tube to the main unit by securing lt ey uf J the air plug to the base of the air connector yJ yp i ad e Securely connect the air tube and the cuff bladder ra set by rotating the luer connection as shown in the Figure on the right C To use the cuff in extra large size only Ne 6 Keep the level of the cuff at the Z same level as the heart during the The extra large cuff comes with an air tube with H uf measurement an integrated air plug Connect the air plug of the a 7 cuff to the air connector securely when Cuff side BILD a SIA connecting to the main unit 14 15 HOW TO USE THE POWER SOURCE HOW TO USE THE POWER SOURCE How to use the AC adapter Installation and Replacement of Battery Pack Z Warning A Warning A Caution If battery fluid gets into your eye or comes in da contact with skin wash the affected area with Do not use this unit in the presence of Be sure to use the AC adapter from the water repeatedly Immediately consult a doctor flammable gas or anesthetics or in a high A power supply of 110 VAC for treatment pressure oxygen room or oxygen tent Do
13. d pressure by using a stethoscope with automatic cuff inflation and deflation by this unit Because the cuff pressures during deflation are displayed digitally and synchronized with the heart beat they can be read with accuracy After taking systolic reading you can accelerate cuff deflation to shorten measurement time e Large and easy to read display Large and easy to read figures are displayed on the LCD display The IntelliSense Monitor inflates the cuff to the ideal level with each use No adjustments are required by the user to select an inflation level This is especially convenient for hypertensive users and for people with certain arrhythmia or heart disorders because their blood pressure is likely to fluctuate The advantage is Personalized Inflation for maximum comfort COMPONENTS OF THE PRODUCT IntelliSense Blood Pressure Monitor Model HEM 907XL Cuff bladder set Extra Large with built in bladder Model HEM 907 CX19 For use with the HEM 907XL unit only Applicable arm circumference 17 to 20 42 to 50 cm AC adapter Model HEM AC J Air tube 1 0m 39 1 3 Model HEM TUBE 100X The air tube is available for the large medium or small cuff size It is NOT for use with the extra large cuff size Battery pack 48H907N Model HEM 907 PBAT Cuff bladder set Large with built in bladder Model HEM 907 CL19 Applicable arm circumference 13 to 17 32 to 42 cm
14. e to be checked based on the manometer read READY TO MEASURE PULSE LEVEL BATTERY CHARGING EXTERNAL 7 Compare the pressure values displayed on the monitor to the one on the manometer L Check result Accuracy of the monitor is validated to be 3 mmHg or 2 of standard manometer reading If your result shows a difference exceeding the tolerance contact Omron repair department 1 877 216 1336 26 2 LIST OF ERROR CODES TROUBLESHOOTING Error code Explanation How to correct If the unit malfunctions during use please check the following Er i Inflation error e When the pressure does not exceed 12 mmHg within the set time after the start of inflation e When the inflation does not reach the set cuff pressure within the specified time after the start of inflation Ere Erg Deflation error e When the deflation speed is too fast during the measurement e When the deflation speed is too slow during the measurement e When the measurement does not finish within the specified time after starting the measurement Overpressure error e The cuff pressure exceeded 299 mmHg e Confirm that the air tube connecting the cuff and the main unit is connected securely e Confirm that the air flow in the air tube connecting the cuff and the main unit isn t being restricted e Confirm that the cuff is wrapped correctly refer to pages 14 and 15 e C
15. efore use Troubleshooting If device error 9 Er9 occurs take the following procedure promptly 1 Remove the cuff from the patient s arm 2 Turn off the power of the unit and unplug the AC adapter from the electric outlet 3 Display Out of use on this unit so that it cannot be used 4 Contact Omron for repair service 1 877 216 1336 OMRON IntelliSense Blood Pressure unit Model HEM 907XL is developed to measure blood pressure and pulse rate accurately and simply in a doctor s office examination room or patient bedside e One button operation Simply wrap the cuff and push the START Button Blood pressure and pulse rate are automatically measured by the oscillometric method e Automatic pressure setting When the P SET Pressure Setting Knob is set to AUTO the unit will automatically inflate the cuff to the optimal pressure according to each patient s blood pressure Pre setting inflation level is not necessary e Noiseless operation This unit operates so quietly that it can be used in the patient room at night e Average Mode AVG Mode In the AVG Mode this unit will automatically measure for two or three times The average of systolic and diastolic blood pressures and pulse rate are displayed Each measurement can also be shown individually The number of measurements waiting time before first measurement and the interval can be changed e Auscultation Mode MANU Mode You can measure auscultatory bloo
16. er the cuff pressure during measurement is displayed This function can be used in the SINGLE and AVG Modes Procedure to change the set values 1 When the power is OFF push the ON OFF power Button for more than three seconds while holding the START Button F1 is displayed By pushing the Button display or non display of status is switched alternatingly SYS 00 l Ei Hid Display 1 Non display 2 Push the START Button and select the function to set from nea F1 to F3 Each time you push the START Button the func iG gt tions change in the order of i ee a mmHg BPM JAC 3 Manual deflation control 3 Push the DEFLATION deflation control Measurement Result Display Switch Button and change the set values Accelerate deflation by pushing the DEFLATION deflation control Measurement Result Display Switch Button during deflation in the measurement by the MANU Mode With each push of the Button cuff is deflated rapidly in increments of 5 to 10 mmHg min a l 4 When the setting is finished push the ON OFF power ia Button to turn off the power The setting is changed 12 13 HOW TO APPLY THE CUFF HOW TO APPLY THE CUFF The cuff of OMRON IntelliSense Blood Pressure Monitor HEM 907XL plays an important role of 3 Place the right or left hand of the patient collecting the information on blood ve
17. ge these factory set values refer to e 6 The measurement results are displayed cy Page 13 is a PULSE g After all the measurements are finished DIA m a LEVEL average values will be displayed J Mi i Each time the DEFLATION deflation control eed Measurement Result Display Switch Button pose sae is pushed the measurement results for each 5 5 NE l reading and the average value will be displayed BPM Ac J exrennat 3 Set the P SET inflation level setting ye Knob to AUTO or the target pressure value S alent e While the battery is in use the monitor will AG exman i turn off after five minutes of inactivity and the display measurement results will disappear Automatic Power Off BATTERY 7 Push the ON OFF power Button to an turn off the power i 4 Measure the patient s arm size and wrap appropriate cuff over the I patient s arm Refer to Pages 14 If the monitor determines that the pressure om and 15 value is not correct an error display appears L Er1 to 9 In this case refer to Page 28 and start the measurement again 22 23 HOW TO MEASURE HOW TO MEASURE BLOOD PRESSURE IN MANUAL MODE BLOOD PRESSURE IN MANUAL MODE 1 Push the ON OFF power Button to 5 Place the stethoscope on the turn on the power patient s arm BATTERY CHARGING EXTERNAL
18. hat the pressure value is not correct patient s arm Refer to Pages 14 an error display appears Er1 to 9 In this case refer to Page and 15 28 and start the measurement again A 20 21 HOW TO MEASURE HOW TO MEASURE BLOOD PRESSURE IN AVERAGE MODE BLOOD PRESSURE IN AVERAGE MODE 1 Push the ON OFF power Button to 9 ee Button to start the turn on the power After the pre select waiting time the unit SENA takes the 1st measurement After displaying the results of 1st cs measurement subsequent measures occur automatically at the specified intervals of Se Ne e For setting the number of measurements oo a a J the waiting time until the 1st measurement w N Heck S and the interval refer to Page 13 A ys e If you want to stop measurement push the STOP Button The unit will rapidly deflate e If an error occurs during measurement the monitor will automatically start measurement ee again If a second error occurs measurement will automatically stop ONOFF O e Do not push the START Button without wrapping the cuff 2 Set the MODE Selector to AVG The factory set values are set as follows e Number of measurements 2 e Waiting time until the 1st measurement 0 sec BATTERY CHARGING m oworra AC EXTERNAL T C e Interval 1 min ar Ic READY TO To chan
19. heck bladder for leaks and if necessary replace the bladder with new one option e Confirm that air flow in the air tube connecting the cuff and the main unit isn t being restricted Trouble What to inspect How to correct The unit inflates to abnormally high low pressure Is the cuff wrapped correctly Wrap the cuff correctly and measure again Refer to Page 14 and 15 Is the patient moving during inflation Ask the patient not to move during measurement and measure again Does this patient have arrhythmia Set the P SET to 30 to 40 mmHg higher than estimated systolic pressure of the patient then measure E 4 Insufficient inflation error e Blood pressure could not be measured due to insufficient inflation level e If the measurement is made by setting the P SET to AUTO ask the patient not to move during the inflation e Confirm that the P SET is securely set to AUTO Turn the Knob counterclockwise as far as it goes until you can hear a click sound e If the measurement is made by manual inflation level setting set the value to 30 to 40 mmHg higher ErS Indeterminable blood pressure error e Blood pressure could not be measured even when the cuff pressure reached the specified pressure e Confirm that the cuff is wrapped correctly refer to pages 14 and 15 Erb Low pulse level error Pulse wave was too small e Confirm that the cuff is wrapped cor
20. is unit Reproducing or copying any or all of this Instruction Manual without OMRON s written Do not disassemble the battery pack consent is prohibited Do not touch the AC adapter with wet hands gt e p NOTES ON SAFETY Unplug the AC adapter from the electric outlet if this unit is unused for an extended period of time Unplug the AC adapter from the electric outlet when installing removing or cleaning the unit Confirm readings with a stethoscope when an irregular pulse wave is displayed or when the measured value is questionable or erratic Use an AC adapter indicated for use with a power supply of 110 VAC Do not share an electric outlet with other unit or electric appliance After cleaning this unit dry it well before plugging the AC adapter in the electric outlet If this unit fails to perform as indicated discontinue use turn off the unit unplug the AC adapter from the electric outlet and contact OMRON s repair department A NOTES ON SAFETY Do not use a cellular phone near this unit Do not use this unit in a vehicle Do not install the parts and or instruments not specified for this unit S Do not use a broken power cord or AC adapter liquid medication This is a Class II device with double isolation Earth pin is not for protective purposes Do not install or store this unit where it may come in contact with water or A General advice D
21. m Remove the clothing and measure again 29 CAUTION CAUTION Changes or modifications not expressly approved by Omron Healthcare Inc could void the user s authority to operate this product NOTE POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the product does cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the product and receiver e Connect the product into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limit
22. magnetic control valve Electrostatic capacity semi conductor pressure sensor AC adapter 120 VAC 60 Hz 20 VA or Battery pack 4 8 VDC 6W Class II B type 50 F to 104 F 10 to 40 C 30 to 85 RH IPX 0 Rating Approx 32 oz 910 g Approx 5 1 2 W x 8 H x 5 1 6 D 139 W x 203 H x 131 D mm Cuff bladder set Extra Large Cuff bladder set Large Cuff bladder set Medium Cuff bladder set Small AC adapter Battery pack air tube 1 0 m Instruction Manual with guarantee card Cuff Extra Large without bladder cuff Large without bladder cuff Medium without bladder cuff Small without bladder Bladder Extra Large bladder Large bladder Medium bladder Small air tube 1 3 m 51 1 6 Stand exclusive for this unit wall hanging kit pole mounting kit Please note that specifications may be changed without prior notice 31 For Customer Service Call Toll Free 1 877 216 1336 Manufactured by OMRON Distributed by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 www omronhealthcare com Copyright 2003 OMRON HEALTHCARE INC HEM 907XLINST Rev A
23. o not disassemble or modify this unit Do not use any cuff other than the models exclusive for this unit Do not use this unit on infants Do not use this unit on patients using a pump oxygenator Do not use an AC adapter or battery pack not specified for this unit Do not place or put anything on this unit Do not drop this unit Turn off power to the unit and unplug the AC adapter from the electric outlet before moving the unit Read the instruction manual of the other devices to be used at the same time with this unit to understand and be aware of the interaction between the devices When using the unit e Do not inflate the cuff without being wrapped over the arm e Do not use a damaged cuff e Be sure that patients do not touch the Buttons of this unit After using the unit e Do not disinfect this unit by autoclave or gas sterilization EtO gluteraldehyde or high concentration ozone Do not install or store this unit in the following places e Under the direct sunlight e Dusty or salty environment e Places having slope vibration and or shock e Storage of chemicals or where combustable gas may be generated e Under high temperature and high humidity NOTES ON SAFETY FEATURES OF THE PRODUCT Maintenance and inspection 1 Check the unit operation on regular basis 2 If this unit has not been used for more than three months be sure to check that this unit operates normally and safely b
24. r consequential damages so the above warranty may not apply to you Any implied warranties arising by the operation of law shall be limited in duration to the term of this warranty Some states do not Mes c UL US Medical Equipment with respect to electric shock fire and mechanical hazards only in accordance with UL 2601 1 and 58JN CAN CSA C22 2 No 601 1 30 allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state As a condition to operation of your warranty the enclosed registration card must be completed and sent to us within 10 days from the date of purchase Name Model Display Measurement Measurement Range Accuracy Inflation Deflation Air Release Pressure Detection Power supply Electric Shock Protection Method Operating Temperature and Humidity Weight of Main Unit External Dimensions Accessories Options FOR CUSTOMER SERVICE CALL TOLL FREE 1 877 216 1336 SPECIFICATIONS OMRON Digital Automatic Blood Pressure Monitor HEM 907XL Digital display Oscillometric method Pressure 0 to 299 mmHg Pulse rate 30 to 199 beats min Pressure Within 3 mmHg or 2 Pulse rate Within 5 of reading Automatic inflation with pumping Automatic deflation by electromagnetic control valve Automatic rapid air release by electro
25. rectly refer to pages 14 and 15 Blood pressure error e Relationship between systolic and dias tolic pressures was abnormal Erg Pulse rate error e Pulse rate did not stay within the range of 30 to 199 beats min e Ask the patient not to move during the measure ment e Check the patient for arrhythmia Erg Device error e Main unit malfunction Contact Omron s repair department toll free at 1 877 216 1336 28 The monitor cannot measure blood pressure Measured values are abnormally high low Check the patient s condition After checking the patient with the stethoscope refer to the list of error codes Refer to Page 28 Is the patient moving during the measurement Ask the patient not to move during measurement and measure again Does the patient have an arrhythmia Set the P SET to 30 to 40 mmHg higher than estimated systolic pressure of the patient then measure Is the size of the cuff correct and is it wrapped correctly Select the cuff according to the patient s arm circumference wrap it correctly then measure again Refer to Pages 14 and 15 Is the level of the brachium to which the cuff is wrapped at the same level as the heart Keep the level of the brachium to which the cuff is wrapped at the same level as the heart then measure again Are the patient s clothes restricting normal blood flow to the ar
26. s for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le ministre des communications FIVE YEAR LIMITED WARRANTY Your HEM 907XL IntelliSense Automatic Blood Pressure Monitor is warranted to be free from manufacturing defects for a period of five years under normal use The five year warranty excludes the monitor cuff The cuff is warranted for a one year period This warranty extends only to the original retail purchaser Should repair be needed within the warranty period ship the unit prepaid to Omron Healthcare Inc 300 Lakeview Parkway Vernon Hills IL 60061 Attn Service Dept together with 5 00 for return shipping and insurance Be sure to include the model number of your unit and your phone number on any correspondence We will either repair or replace at our option free of charge any parts necessary to correct defects in the materials or workmanship The above warranty is complete and exclusive The warrantor expressly disclaims liability for incidental special or consequential damages of any nature Some states do not allow the exclusion or limitation of incidental o
27. ssels Please wrap the cuff according to the procedure below with the palm of hand facing upward A Warning Do not wrap the cuff over an arm to which intravenous injection or transfusion is being conducted or when otherwise contraindicated S 4 Align the Artery Position Mark T Do not connect the air tube or the cuff to other with the brachial artery equipment which is connected to intracorporeal organ Air embolisms may result General advice e Do not inflate the cuff without being wrapped over the arm e Do not use a damaged cuff 5 Wrap the cuff snugly using both hands and securely fasten it with the Velcro tape At this time the lower edge of the cuff must be placed 1 2 to 1 above the inner side of elbow joint 1 Select the cuff according to the arm size Arm circumference Name of the cuff 7 9 17 22 cm HEM 907 CS19 Small e If the INDEX is positioned outside the RANGE select the cuff suitable for the 9 13 22 32 cm HEM 907 CR19 Medium patient s arm circumference and wrap it again 13 17 32 42 cm HEM 907 CL19 Large e Wrap the cuff so that you can insert only one finger between the cuff and arm 17 20 42 50 cm HEM 907 CX19 Extra Large e Check the following before applying the cuff 1 The bladder is correctly installed in the cuff 2 The bladder is not twisted inside the cuff 3 The bladder tube is protruding from the
28. y be shortened depending on the state of using If the interval between charging becomes short and the __J icon appears frequently replace it Charging time e At approximately five seconds after connecting the AC adapter the unit will start battery charging automatically e While the battery is being charged the gt icon turns on e The battery can be completely charged in approximately twelve hours Battery low_ gt e When the d l icon starts to blink twenty to thirty measurements remain on the battery N However if the Battery Low Mark starts to blink charge it soon e If the 4 icon is displayed the battery is low and the unit cannot operate Please charge the battery Automatic Power Off e When using the unit with the battery the unit will turn off automatically after five minutes of inactivity e While the AC adapter is connected the Auto Power Off function does not work 18 A Warning If cuff inflation does not stop remove the cuff or pull out the air tube from the main unit Confirm readings with the stethoscope when an irregular pulse wave is displayed or when Q the measured value is questionable or erratic General advice e Patients should not touch the unit List of Measurement Modes To measure only once To measure two times or three times automatically and consecutively To measure by using a stetho MANU Mode scope Do not use a cellul