1. 4 YEAR MADE IN C WAWRANTY USA OS35 20 Shop online at omega com O OMEGA omega com e mail info CQomega com For latest product manuals omegamanual info 09535 Sarias Smart Infrared Temperature Sensors omega com OZOMEGA OMEGAnet Online Service Internet e mail omega com infoQomega com U S A ISO 9001 Certified Canada Servicing North America One Omega Drive P O Box 4047 Stamford CT 06907 0047 TEL 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 Canada TEL 514 856 6928 FAX 514 856 6886 e mail infoQomega ca For immediate technical or application assistance U S A and Canada Sales Service 1 800 826 6342 1 800 TC OMEGAS Mexico Czech Republic Germany Austria United Kingdom ISO 9002 Certified Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info omega com mx Servicing Europe Frystatska 184 733 01 Karvina Czech Republic TEL 420 0 59 6311899 FAX 420 0 59 6311114 Toll Free 0800 1 66342 e mail info omegashop cz Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de One Omega Drive River Bend Technology Centre Northbank Irlam Mancheste
2. WA Plug in Cards for Apple IBM amp Compatibles lA Datalogging Systems l Recorders Printers amp Plotters HEATERS WA Heating Cable WA Cartridge amp Strip Heaters WA Immersion amp Band Heaters lA Flexible Heaters lA Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL WA Metering amp Control Instrumentation lA Refractometers WA Pumps amp Tubing lA Air Soil amp Water Monitors lA Industrial Water amp Wastewater Treatment WA pH Conductivity amp Dissolved Oxygen Instruments M4252 1007
3. 3 mm x 0 75 diameter snout leakage current in your input device e Custom scaling and programming for low emissivity materials and low temperatures available Temperature Range Accuracy Repeatability Interchangeability 30 70 C 0 100 C amp 0 250 C 1 C or 1 1 C 1 8 F or 0 5 1 5 C or 1 5 1 5 C or 1 5 1 BIT 1 C 1 8 F or 0 5 30 70 C 0 1 C 0 100 C 0 1 C 0 250 C 0 25 C 0 500 C 0 5 C 0 1000 C 1 C 1 5 C or 1 5 OS35 20 0 100 C 0 250 C amp 0 500 C 1 5 Cor 1 5 1 C 1 8 F or 0 5 0 1000 C 1 5 C or 2 0 NE 888 TC OMEGA USA Canada 203 359 1660 International at OS35 Infrared Temperature Sensor Installation Instructions Install OS35 as close as practical to view target material to be measured 2 Wire OS35 with Red to Positive Power Black to Ground White to Positive Output Signal and Green to Reference Output Signal 3 Measure actual temperature of target material with OS950 Thermometer or any reliable reference 4 Adjust offset zero or low cal on input device to match reading to ac tual thermometer reading 5 Installation calibration complete ERROR MESSAGES Under 0 1V Under 0 1V Under 4mA Not
4. Implemented Hardware Internal 2 Uniform Flash Over 4 9 V Over 9 8V Over 19 7mA Not Implemented Errors Vsig Offset High Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Vsig Offset Low Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented High Ambient Too Much Heat Flow Long Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Short Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Long Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Too Little Heat Short Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Flow High Target Long Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented NEN Short Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented Six counts off one count on Six counts on one count off o Uniform Flash Over 4 9V Over 9 8V Over 19 7mA Not Implemented 1 13 3 4 5 7 10 11 12 PIN OUT A la Positive Output Signal ca TA Pull Down Pin IO option ET E AVAILABLE MODELS OS35 20 MA 1000C 24V Infrared temperature sensor 20 1 optics 0 to 1000 C range Note Note For 12 V power requirement change 24 V in Model number to 12 V no price change For 5 V output change MA to 5 V no price change For 10 V output which is available only on 24 V power models change MA to 10 V no price change For RS232 output which is available only on 250 C range with 12 V power chang
5. djustments Indi vidual calibration is not required WIRING DIAGRAM LI POWER 4 L SIGNAL OUTPUTEND 2 PIN OUT Carol C074 Series Belden 953 Series Alpha 630 Series 1 Positive Output Signal uu Reference Output Signal R5232 TXD 1O option Shield RS232 CTS CLEAR TO SEND ORDERING INFORMATION SmartIRt c F P O T or Smart microIRt c F P O T F is SV 4 4SV only for Smart microIRt c FIELD OF VIEW P POWER O OUTPUT T TEMPERATURE RANGE 12V 12 VDC 05 0 5V 100C 0 100C 24V 24 VDC 010 0 10V 250C 0 250C 420 4 20 mA 500C 0 500C 232 RS232 1000C 0 1000C 70C 30 70C OPTION Add Ta to any part to add ambient temperature option to output ambient temperature surrounding sensor NOTE 0 10V only available in 24VDC and RS232 only available in IZVDC from 0 250C Examples SmartIRt c 3 24V 420 250C 3 1 field of view 24VDC power 4 20mA output from 0 250C Smart microIRt c 12V 05 250C 1 2 field of view IZVDC power 0 5V output from 0 250C or SmartIRt c 3 24V 420 250C Ta with 4 20mA outputting target temperature and ambient temperature from 0 250C 0 5V 0 10V 4 20mA RS232 Sensing Range 30 to 70 C 0 to 100 C 0 to 250 C 0 to 500 C or 0 to 1000 C Ambient Temperature Range 0 C to 70 C internal case temperature Storage Temperature Range 10 C to 70 C TT ENA 1 2 3 1 4 1 5 1 20 1 or 40 1 distance spot Minimum Spot size 3 mm 0 1 Smart micro 5 mm 0 2 Smart 16 mm 0 625 Sma
6. e MA to RS no price change Comes with air tubing Ordering Example 1 OS35 3 MA 100C 24V LINEAR 30 70 C 22 158 F 0 100 C 32 212 F 0 250 C 32 482 F 0 500 C 32 932 F 0 1000 C 32 1832 F TEMPERATURE RANGES WA g r custom scaling also available upon request 0 250 C 32 482 F OUTPUT 0 5V 0 10V 24VDC power only 4 20mA 50 ohm max RS232 12VDC power only UPDATE TIME Approximately 250 msec FIRST READING UPON POWER UP Approximately 2 seconds EMISSIVITY 0 90 custom low emissivity settings available for metals etc upon request SETTING SPECTRAL 5 5 to 20 microns other ranges available for specific applications thin films etc RESPONSE POWER 12 or 24 VDC 1090 Shuts off when voltage is functionally low OUTPUT 750 ohms on 0 5V and 0 10V models IMPEDANCE MINIMUM LOAD 100 K ohms IMPEDANCE MAXIMUM LOOP 1 K ohm max IMPEDANCE POWER CONSUMPTION lt 800 mW at 24 VDC and 600 mW at 12VDC Ambient Temperature Range 0 to 70 C 32 to 158 F Storage Temperature 10 to 70 C 14 to 158 F Construction Heavy Duty Alloy Casting Weight Approximately 8 oz 227 g Relative Humidity 95 non condensing Air Purge Integral built in air purge with small sized aperture and heat exchanged which minimizes drift for superb accuracy Cable 3 ft 0 9 m of 5 conductor tinned copper twisted pair polypropylene insulated with shielded wi
7. hanges whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2007 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do Find Everything Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE WA Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies WA Wire Thermocouple RTD amp Thermistor lA Calibrators amp Ice Point References lA Recorders Controllers amp Process Monitors lA Infrared Pyrometers PRESSURE STRAIN AND FORCE WA Transducers amp Strain Gages WA Load Cells amp Pressure Gages lA Displacement Transducers WA Instrumentation amp Accessories FLOW LEVEL WA Rotameters Gas Mass Flowmeters amp Flow Computers WA Air Velocity Indicators WA Turbine Paddlewheel Systems WA Totalizers amp Batch Controllers pH CONDUCTIVITY WA pH Electrodes Testers amp Accessories lA Benchtop Laboratory Meters lA Controllers Calibrators Simulators amp Pumps WA Industrial pH amp Conductivity Equipment DATA ACQUISITION lA Data Acquisition amp Engineering Software lA Communications Based Acquisition Systems
8. it but functionality or accuracy is not guaranteed when exceeding the Recommended Power Supply voltage At room temperature ek Current Output 10bit 0 20mA MADE AN USA WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s WARRANTY adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGAS customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGAS control Components in which wear is not warranted include but are no
9. r M44 5BD United Kingdom TEL 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sales omega co uk It is the policy of OMEGA Engineering Inc to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications 1 885 TC OMEGA USA amp CANADA 1 204 359 1660 INTERNATIONAL 0535 HIGHLIGHTS e Smartair purge assures maintenance free long term accuracy e Smart continuous auto calibration e All digital system e Smart housing resists mechanical and thermal shocks Smart emissivity shift and ambient radiation O correction 4 Oj e Easy plug and play installation e Lowest cost air purged lineafzed sensor on the market e Optics of 3 1 amp 20 1 available OS35 3 3 1 FOV KAN Outputs of 0 5V 0 10V 4 20mA amp RS232 Temperature ranges from 22 1832 F 30 1000 C 3 71 x 1 37 x 0 76 94 3 x 34 9 x 19 4 mm OS35 20 20 1 FOV e LOW impedance results in nooffset errors due to a amp 1 63 41
10. re Ratings NEMA IP54 with air on OS35 F P O T F FIELD OF VIEW P POWER O OUTPUT T TEMPERATURE RANGE 3 3 1 12V 12 VDC 05 0 5V 70C 30 70C 24V 24 VDC 010 0 10V 100C 0 100C 20 20 1 420 4 20 mA 250C 0 250C 232 RS232 500C 0 500C 1000C 0 1000C OPTION Add Ta to any part to add ambient temperature option to output ambient temperature NOTE 0 10V only available in 24VDC and RS232 only available in IZVDC Example OS35 3 24V 420 250C with 4 20mA output measuring target temperature from 0 250C or OS35 3 24V 420 250C Ta with 4 20mA outputting target temperature and ambient temperature from 0 250C FE OMEGA OS35 800 826 6342 USA Canada ma OSBS RS nase Infrared Temperature Sensor INSTALLATION INSTRUCTIONS The following procedure is recommended Oto 40V Oto EV te oma l Install the SmartIRt c as close as practical to view the target material to be p measured l 2 Wire the SmartIRVc to the controller PLC etc in standard fashion see PIN OUT and wiring diagram 3 Bring the process up to normal operating temperature and measure the actual temperature of the target material with the Microscanner D Series DX Series Infrared Thermometer or any other reliable reference SIGNAL OUTPUT 1 won e JE pek 3 4 Adjust input offset zero low cal on the readout device to match the Ni Z GND 5 reading of your reference i Installation Complete For OEM installations preset the same a
11. rtIRt c 20 and 40 Dominant Spectral Response 5 to 14 um Smart micro 5 5 to 20 um Smart Impedance Emissivity Setting e 0 90 can be factory adjusted Measurement Type Thermopile 10 bit 4 Digit w floating decimal Less than 250ms after first reading Resolution Update Time Response Time 95 of step change Bandwidth Less than 650 ms Typically SHz First Reading in Less than 2 seconds Accuracy Includes Repeat ability and Interchangeability Recommended Power Supply Typically 1 C 1 8 F or 1 of reading ate 0 9 12 10 V DC or 24 10 V DC depending on model Power Accepted Shuts off when voltage is functionally low Power Consumption 12V power less then 400mW 24V Power less than 800 mW Dimensions Contact Exergen for Drawing Zinc Aluminum Alloy Z 12 ISO DIS 301 3 foot pigtail and 3 feet from sensor to box on Smart microIRt c Housing Sensor Connection l DB9 and loose power wires Recommended Air Purge Pres sure Maximum Air Pressure 3 PSI Contact Exergen for Pressure Flow Error Graphs 20 PSI may cause reading errors Instrument Air is Recommended ANSI ISA 7 0 01 1996 Non Condensing ISA 71 01 1985 Environment Class C Severity X 100G Approximately 200 grams 70z Air Cleanliness Humidity Shock Weight mi o Constantly on for normal operation The unit will not give an error message if the input voltage exceeds recommended high lim
12. sused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the FOR NON WARRANTY REPAIRS consult OMEGA following information available BEFORE for current repair charges Have the following contacting OMEGA information available BEFORE contacting OMEGA 1 Purchase Order number under which the product 1 Purchase Order number to cover the COST was PURCHASED of the repair 2 Model and serial number ofthe product under 2 Model and serial number of the product and warranty and 3 Repair instructions and or specific problems 3 Repair instructions and or specific problems relative to the product relative to the product OMEGA s policy is to make running changes not model c
13. t limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or mi