1. LV850 LEVEL SENSOR y NOTES LV850 LEVEL SENSOR 1 Description Level Sensor LV850 is suitable for liquids with low relative dielectric constant e g oil Units come with Minimum and Maximum selector switch It operates on the principle of electrical capacitance changes arising when an electrode surrounded by air is immersed in the medium e LED status display e Selection of minimum and maximum function by changeover switch Minimum switching Normally the sensor is immersed and the green LED indicates As the level drops below the sensor the green LED extinguishes Maximum switching Normally the sensor is not immersed and the green LED indicates As the level rises above the sensor the green LED extinguishes e In the event of a short circuit in the load circuit the green LED will extinguish and the red LED will flash Minimum Maximum switch position 1 switch position 2 LED LED medium level transistor output medium level transistor output green red load o Q LV850 LEVEL SENSOR 2 Technical Data Temperature range 20 C to 130 C 4 F to 266 F short time to 150 C 302 F Ambient temperature 20 C to 85 C 4 F to 185 F Pressure resistance max 25 bar 367 5 PSI Response delay approx 0 1 s Degree of protection IP 65 Input voltage DC 9 36 V Option metal coupling for pipe extension see fig 2 if the sensor is to be used as an immersion sens
2. 7 Increase the level until the Level Sensor is immersed in the medium 8 Minimum Sensor e Turn the potentiometer screw E to until the LED green extinguishes Then slowly turn to until the LED indicates Adjust the screw a further full turn to to compensate for any tolerance 9 Maximum Sensor e Turn the potentiometer screw E to until the LED green extinguishes Then slowly turn to until the LED indicates Adjust the screw a further full turn to to compensate for any tolerance 10 Replace and tighten the cover C or the metal coupling option 11 Replace and tighten the cable gland nut PG7 The Level Sensor is now connected adjusted and ready for operation 5 Operating Difficulties Problem The Level Sensor fails to operate correctly Solution The surface of the sensor probe should be carefully cleaned from inside the container LV850 LEVEL SENSOR y NOTES WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s Warranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized
3. A YEAR C WARRANTY Shop online at omega com LE OMEGA omega com e mail info omega com For latest product maunuals omegamanual info 1509001 CERTIFIED CERTIFIED CORPORATE QUALITY CORPORATE QUALITY STAMFORD CT MANCHESTER UK LV850 Level Sensor omega com OEOMEGA OMEG Anet Online Service Internet e mail www omega com info omega com USA ISO 9001 Certified Canada Servicing North America One Omega Drive Box 4047 Stamford CT 06907 0047 Tel 203 359 1660 FAX 203 359 7700 e mail info omega com 976 Bergar Laval Quebec H7L 5A1 Canada Tel 514 856 6928 FAX 514 856 6886 e mail info omega ca For immediate technical or application assistance USA and Canada Mexico Benelux Czech Republic France Germany Austria United Kingdom ISO 9002 Certified Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN TELEX 996404 EASYLINK 62968934 CABLE OMEGA En Espa ol 001 203 359 7803 e mail espanol omega com FAX 001 203 359 7807 info omega com mx Servicing Europe Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 0 20 3472121 FAX 31 0 20 6434643 Toll Free in Benelux 0800 0993344 e mail sales omegaeng nl Frystatska 184 733 01 Karvina Czech Republic Tel 420 0 59 6311899 FAX 420 0 59
4. 6311114 Toll Free 0800 1 66342 e mail info omegashop cz 11 rue Jacques Cartier 78280 Guyancourt France Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail salesQomega fr Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de One Omega Drive River Bend Technology Centre Northbank Irlam Manchester M44 5BD United Kingdom Tel 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sales omega co uk It is the policy of OMEGA to comply with all worldwide safety and EMC EMI regulations that apply OMEGA is constantly pursuing certification of its products to the European New Approach Directives OMEGA will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for human applications LV850 LEVEL SENSOR Please follow these installation connection and adjustment instructions carefully Failure to comply with these instructions or misuse of this equipment will void your warranty Equipment installation connection and adjustment by qualified personnel only
5. ILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for ship
6. Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibra tion improper specification misapplication misuse or other operating conditions outside of OMEGA Ss control Components which wear are not warranted including but not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESS OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTASBILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIAB
7. ibrators amp Ice Point References lA Recorders Controllers amp Process Monitors A Infrared Pyrometers PRESSURE STRAIN AND FORCE lA Transducers amp Strain Gages lA Load Cells amp Pressure Gages lA Displacement Transducers lA Instrumentation amp Accessories FLOW LEVEL lA Rotameters Gas Mass Flowmeters amp Flow Computers lA Air Velocity Indicators lA Turbine Paddlewheel Systems A Totalizers amp Batch Controllers pH CONDUCTIVITY lA pH Electrodes Testers amp Accessories lA Benchtop Laboratory Meters lA Controllers Calibrators Simulators amp Pumps A Industrial pH amp Conductivity Equipment DATA ACQUISITION lA Data Acquisition amp Engineering Software lA Communications Based Acquisition Systems lA Plug in Cards for Apple IBM amp Compatibles lA Datalogging Systems 14 Recorders Printers amp Plotters HEATERS lA Heating Cable lA Cartridge amp Strip Heaters lA Immersion amp Band Heaters A Flexible Heaters 4 Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL lA Metering amp Control Instrumentation lA Refractometers LA Pumps amp Tubing LA Air Soil amp Water Monitors lA Industrial Water amp Wastewater Treatment lA pH Conductivity amp Dissolved Oxygen Instruments M3808 0504
8. or C mark to demonstrate compliance with applicable directive LV850 with G3 4A thread approx 150 5 91 66 2 60 130 5 12 approx 150 5 91 DIMENSIONS mm in LV850 LEVEL SENSOR 3 Level Sensor Installation r The Level Sensor may be installed in any attitude 1 Ensure sufficient clearance space see Fig 1 in the container wall e Ensure a type 3 4 NPT or G3 4A thread in the container wall has been provided 2 Screw the Level Sensor into the threaded aperture using a recognized sealing material 3 When tightening the level sensor please use the flats provided SW32 Do not overtighten Metal coupling option 45 1 77 DIMENSIONS mm in LV850 LEVEL SENSOR y 4 Connection A Check that the supply voltage corresponds with the voltage rating shown on the system 1 Loosen the gland PG7 see Fig 1 2 Unscrew the cover of the housing C 3 Feed the supply cable through the gland PG7 and the cover C or through the metal coupling supplied as option see Fig 2 4 Connect the cable to the terminal block TB see Fig 3 5 Set selector switch S to minimum or maximum 1 minimum 2 maximum 6 Connect the supply voltage LED red indicates selector switch S sensitivity adjustment 15 turn adjustment screw without final stop external o load free wheeling LV850 LEVEL SENSOR
9. ping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have FOR NON WARRANTY REPAIRS consult the following information available BEFORE OMEGA for current repair charges Have the contacting OMEGA following information available BEFORE 1 Purchase Order number under which contacting OMEGA the product was PURCHASED 1 Purchase Order number to cover the COST 2 Model and serial number of the product of the repair under warranty and 2 Model and serial number of the product and 3 Repair instructions and or specific 3 Repair instructions and or specific problems problems relative to the product relative to the product OMEGA s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2004 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do Find Everything Need for Process Measurement and Control OMEGA Of Course Shop online at www omega com TEMPERATURE lA Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assemblies lA Wire Thermocouple RTD amp Thermistor 14 Cal