Home
Nikon Monarch/Titanium User's Manual
Contents
1. Abb 3 14 6 Zero setting of grip except 6 5 20x44 Fig 3 14 After the reticle has been adjusted to the point of impacts with the grip held with your fingers to avoid shifting of the aligned grip turn the grip screw in top of the grip counterclockwise with coin Then lift the grip up and align the with the index mark It may happen that the Y could not align with the index mark exactly because of the coupling pitch of the grip with the shaft And by securing the grip with your fingers to avoid shifting of the grip turn the grip screw clockwise with the coin until the grip is firmly secured Note The windage and elevation scales of the Nikon Riflescope 1 5 4 5x20 4x40 and 2x20 are calibrated in divisions of Y minute of angle with a click at intervals of 4 minute of angle half division The windage and elevation scales of the Nikon Riflescope 3 5 10x50 3 3 10x44 AO 4 12x40 AQ 5 5 16 5x44 AO 3 9x40 2 7x32 1 5 4 5x24 2 5 8x28 and 6x42 are calibrated in division of 1 4 minute of angle with a click at intervals of 14 minute of angle one division The windage and elevation scales of the Nikon Riflescope 6 5 20x40 AO are calibrated in division of 1 8 minute of angle with a click at intervals of 1 8 minute of angle one division When adjusting the reticle to the point of aim remember that one minute of angle equals approximately one inch 2 54 cm at 100 yards 91 44 m Therefore if the impact poin
2. Nikon Riflescope Monarch Titanium 6 5 20x44 AO 5 5 16 5x44 AO 4 12x40 AO 3 3 10x44 AO 3 5 10x50 1 5 4 5x20 2 5 8x28 6x42 3 9x40 2 7x32 4x40 2x20 Instruction Manual Congratulations on your choice of a Nikon RIFLESCOPE Your new scope is the finest example of Nikon s rugged and durable construction and precision bright optics important qualities for a serious shooter s riflescope Whether you use your scope for hunting or for target shooting the procedure for mounting is identical You should acquire a set of high quality steel mounting rings which have a standard diameter of 25 4 mm 1inch Follow the ring manufacturer s instructions for mounting procedures After mounting the scope on your rifle follow the procedures for reticle alignment Caution 1 Do not look at the sun through the riflescope It will permanently damage your eye This precaution applies to all optical devices such as cameras and binoculars 2 The riflescope is effectively sealed against moisture and dust You may use your scope safely either in the rain or in dusty climates To preserve the appearance of the scope we suggest that it be dried and cleaned prior to storage Use a soft cloth for cleaning metal surfaces and use photographic lens tissue to clean the scope s lenses When setting the reticle for hunting you should determine your standard range and then adjust the reticle based upon that target distance For targets which vary from the
3. S 83 Parallax Sotting at Ieast 45 72 os at least 50 00 Outside Diameter of mm o Eyepiece 2 MO Actual Magnification 1 5 4 5 Objective Diameter JET 16 4 6 0 63 0 18 99 1 91 4 TEN 3 9 3 6 12 30 9 13 Wr 6 3 9 40 12 5 12 7 g g 23 33 5 Eye Relief sk 33 Field of View at 100yds 3 T be 29 Tube Diameter 3 s Objective Tube Dia s a gt 3 33 wr amp Adjustment Gradualion 1 4 1 click 1 4 1 div Vn Click 1 41 click 1 43 click 1 21 div 1 41 div 1 411 div 70 Eyepiece ak moa minule of angle Nikon riflescopes are factory set to be parallax free at 100 yds 91 44 m 6 5 20x44 AD 3 3 10x44 AD 4 12x40 0 and 5 5 16 5x44 AD allow free adjustment from 50 yds up to infinite point 1 5 4 5x20 is factory set to be parallax free at 50 yds 45 72 m or 75 yds 68 58 m 50 yds for Diamond Reticle type 75 yds for Nicoplex Reticle type al 50 yds at 75 yds at minimum magnification at maximum magnification ITEMS SUPPLIED Body 1pc Eyepiece Cap oa 1 pair Objective Cap Grips 6 5 20x44 only 2pcs Hex Key 6 5 20x44 only 1pc Instructions 1 Focusing 1 Look through the eyepiece with your eye positioned about 10cm 4 in away from the eyepiece lens Fig 3 1 and you will see the Nikoplex reticle Fig 3 2 the Crosshair w
4. ection of the arrow marked U Fig 3 11 If the bullet hits to the left of the aiming point turn the grip in the direction of the arrow marked R Fig 3 12 4 Adjustable objective The Nikon Riflescope 6 5 20x44 AO 4 12x40 AO 3 3 10x44 AO and 5 5 16 5x44 AO can be more precisely focused within the range of at least 50 yards 45 72 m infinity by rotating the objective adjusting ring Parallax can be eliminated and sight alignment will be accurate Use its distance scale as a reference guide Rotation of the adjusting ring is intentionally adjusted to be heavy at the factory so that it will not move easily during shooting b Changing the grip 6 5 20x44 only Remove the protective cap of the grip by turning it counterclockwise Align the grip to the O zero position of the scale ring This is to assure that the scale ring will be correctly aligned to the new grip the alignment position should be remembered With the grip held with your fingers to avoid shifting of the aligned scale ring turn the bolt in the top of the grip counterclockwise with the hex key supplied until the bolt comes out Then remove the grip Fig 3 13 Insert the new grip into position and align the scale ring to O Insert the bolt By securing the grip with our fingers to avoid shifting of the scale ring turn the bolt clockwise with the hex key supplied until the grip is firmly secured Fig 3 10 Fig 3 12 Fig 3 14
5. et Suite 100 El Segundo CA 90245 4721 1 800 Nikon SV In other market please bring it to dealer from which you purchased it Nikon Inc 1300 Walt Whitman Road Melville NY 11747 3064 P 631 547 8632 F 631 547 4040
6. ith dot reticle Fig 3 3 or the Turkey Pro reticle Fig 3 4 the Crosshair reticle Fig 3 5 or the Miliradian Dot reticle Fig 3 6 or the BDC reticle Fig 3 7 Be sure your eye is positioned within proper alignment and proper eye relief otherwise the view will black out 2 Point the objective end of the scope at the sky Do not point at the sun or at a plain unpatterned wall Loosen the lock ring 2x20 only Turn the eyepiece adjustment counter clockwise and then turn it clockwise until the reticle appears sharp 2x20 only 3 Finally without moving the eyepiece adjustment turn the eyepiece lock ring as Fig 3 8 to end so that the eyepiece adjustment will be firmly locked The lock ring must be firmly tightened to ensure an air tight seal cB m Fig 3 2 2x20 only 1 Lock Ring SM TA atum E Abb 3 2 Fig 3 1 Abb 3 1 ipd Fig 3 3 Abb 3 3 1 Eyepeice Adjustment u Turkey Pro Reticle 1 5 4 5x20 only 2 Eye Relief Fig 3 4 Abb 3 4 Eyepiece Adjustment Okulareinstellung R glage d oculaire Dispositivo de ajusle del ocular 2x20 only Regolatore oculare Lock Ring Sperring Bague de verrouillage Anillo de bloqueo Anello di blocco Fig 3 8 Abb 3 8 Crosshair Reticle 6 5 20x44 AO only Fig 3 5 Abb 3 5 Miliradian Dot Reticle 3 3 10x44 AO only Fig 3 6 Abb 3 6 BDC Reticle 3 9x40 3 5 10x50 4 12x40 6 5 2 x44 5 5 16 5x44 Fig 3 7 Abb 3 7 The reticle should be immedia
7. rn Grip Vergr flerte Darstellung des Handdrehgrifts Sch ma agrandi de la poign e rotation manuelle Ilustracion ampliada del cilindro de ajuste manual Figura ingrandita dell impugnatura a rotazione manuale i T 4 12x40 A0 Abb 1 6 Magnified Figure of 1 5 4 5x20 4x40 2x20 Hand turn Grip VergriBerte Darstellung des 1 5 4 5x20 4x40 2x20 Handdrehgriffs Sch ma agrandi de la poign e rotation manuelle 1 5 4 5x20 4x40 2x20 Ilustracion ampliada del cilindro de ajuste manual 1 5 4 5x20 4x40 2x20 Figura ingrandita dell impugnatura a rolazione manuale 1 5 4 5x20 4x40 2x20 Fig 1 10 229 Abb 1 10 2 Specifications 6 5 20x44 A0 rng 5 10x50 4 214040 55105 crt 3 9x40 MONARCH NARCH MONARCH MONARCH MONARCH MONARCH Objeclive Diameter om 40 in 5 L 157 6 8 22 133 44 827 133 44 0 27 0 09 0 52 0 17 aso 039013 0 31 0 11 0 52 0 17 Eye Relief 88 9 78 7 914 914 91 FEV 4 81 3 76 2 91 4 88 9 o 35 31 36 36 3 6 3 2 3 0 36 35 Field of View at 100yds 49 16 93 31 7 8 5 8 2 0 10 3 3 4 16 1 5 4 30 4 10 1 255 8 Beas 19 1 6 4 33 8 11 3 2 emn E e b e io PI pr 158 495 530 645 370 1 17 4 18 7 22 8 13 0 1 41 click 1 4 1 click 1 4 1 click 1 4 1 click 1 4 1 div 1 41 div 1 4 1 div 1 4 1 div at loast 45 72 21 loast 45 72 00 Adjustment Graduation Click 1 41 1 8 1 div 141 Calon H Windage dcin se 72 EE Fal H B 2 E
8. standard distance you may simply adjust the position of the reticle in relation to your target or you may wish to use the procedure for trajectory compensation It s up to your personal preference We hope that you will enjoy your new Nikon RIFLESCOPE for many years to come Enjoy using it and above all always follow safe shooting procedures The product s described herein may be subject to export control regulations in the relevant country ies It they should not be exported without authorization of the exporting governmental authority if the regulations apply 1 Nomenclature Objective Lens Eyepiece Lens Elevation Adjustment Windage Adjustment Eyepiece Lock Ring Eyepiece Adjustment Power Index Dot Power Scale Power Selector Ring Adjustable Objective Adjustment Ring Adjustable Objective Distance Scale Distance Index Dot Adjustment Cap Ne n mim sca n Fig 1 1 Option Hood Wahlfeiheit Haube 6 5 20x44 A0 Abb 1 1 Option Pare soleil Opti n Funda Opzione Paraluce M s i t mnn G mmi n i Fig 1 3 3 3 10x44 A0 Abb 1 3 5 5 16 5X44 A0 Grips for Elevation TIT Easy Grips standard grip Fig 1 2 Grip for Windage e standard p s e Easy Grips grip i Fig 1 4 Magnified Figure of Abb 1 4 1 5 4 5x20 d a Fig 1 5 3 5 10x50 3018 Abb 1 5 2 7x32 1 5 4 5x20 2 8 8x28 Magnilied Figure of Hand tu
9. t is two inches 5 08 cm low and one inch 2 54 cm right at 100 yards 91 44 Parallax Setting you should adjust two minutes of angle up one minute of angle left In case of 50 yards 45 72 m Parallax Setting the adjusting value is double In case of 75 yards 68 58 m Parallax Setting is 1 5 times Maintenance 1 Lens cleaning To remove dirt or fingerprint soak gauze or lens cleaning paper silicon free paper sold at camera shop with a small quantity of absolute alcohol available form drugstore and lightly wipe off Wiping with leather chamois is not recommended as it is likely to damage the lens surface Dust may scratch the lens surface or corrode the lens Brush dust off using a soft oil free brush 2 Scope Exterior Use a soft dry cloth to wipe off any dirt or fingerprints that might accumulate It is not necessary to oil the scope s surface 8 Windage Elevation Adjustments These adjustments are permanently lubricated Do not attempt to lubricate them Cover with caps supplied except when adjusting to keep out dust and dirt 4 Eyepiece Adjustment This adjustment is permanently lubricated Do not attempt to lubricate b Power Selector Ring No lubrication is required on the power selector ring Do not loosen or remove screws in power selector ring In the event that you should require service for your Nikon RIFLESCOPE in case of USA market please send it directly to Nikon Scope Service 841 Apollo Stre
10. tely crisp and clear to the quick glance 2 Magnification e The Nikon Riflescope 6x42 has a fixed magnification of 6X 4x40 of 4x 2x20 of 1 75X e The Nikon Riflescope 3 9x40 has a variable magnification from 3 to 9X 2 7x32 from 2 to 7X 1 5 4 4x20 from 1 5 to 4 5X 4 12x40 AO from 4 to 16 5X 3 5 10x50 from 3 5 to 10X 3 3 10x44 AO from 3 3 to 10X 2 5 8x28 from 2 5 to 8x To change powers just rotate the power selector ring until the desired magnification appears adjacent to the power index dot 3 Adjustment of the riflescope Sighting through the riflescope align the rifle with your aiming point on the target and shoot a trial round If the bullet does not hit the aiming point adjust the elevation and windage as follows e If the bullet hits under the aiming point turn the elevation adjustment counter clockwise in the direction of the arrow marked U for up as in Fig 3 9 If the bullet hits high turn adjustment clockwise in the direction of the arrow marked D for down fthe bullet hits to the right of the aiming point turn the windage adjustment clockwise in the direction of the arrow marked L for left as in Fig 3 10 If the bullet hits to the left of the aiming point turn adjustment counter clockwise in the direction of the arrow marked R for right e For the Nikon Riflescope 6 5 20x44 AO adjustment is made by turning the grip by hand If the bullet hits under the aiming point turn the grip in the dir
Download Pdf Manuals
Related Search
Related Contents
Laboratory Experiment 8 EE348L Documentación técnica 安全コンセプトチェックシート(見守り用SG採点案) AKG Home Cinema Speaker System HKTS 7 Unidad Exterior HP 86-155 MBH M186 Sakamoto Whole Body Pregnant Model Copyright © All rights reserved.
Failed to retrieve file